Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
JAMA ; 331(12): 1015-1024, 2024 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-38460161

RESUMEN

Importance: Drug-coated balloons offer a potentially beneficial treatment strategy for the management of coronary in-stent restenosis. However, none have been previously evaluated or approved for use in coronary circulation in the United States. Objective: To evaluate whether a paclitaxel-coated balloon is superior to an uncoated balloon in patients with in-stent restenosis undergoing percutaneous coronary intervention. Design, Setting, and Participants: AGENT IDE, a multicenter randomized clinical trial, enrolled 600 patients with in-stent restenosis (lesion length <26 mm and reference vessel diameter >2.0 mm to ≤4.0 mm) at 40 centers across the United States between May 2021 and August 2022. One-year clinical follow-up was completed on October 2, 2023. Interventions: Participants were randomized in a 2:1 allocation to undergo treatment with a paclitaxel-coated (n = 406) or an uncoated (n = 194) balloon. Main Outcomes and Measures: The primary end point of 1-year target lesion failure-defined as the composite of ischemia-driven target lesion revascularization, target vessel-related myocardial infarction, or cardiac death-was tested for superiority. Results: Among 600 randomized patients (mean age, 68 years; 157 females [26.2%]; 42 Black [7%], 35 Hispanic [6%] individuals), 574 (95.7%) completed 1-year follow-up. The primary end point at 1 year occurred in 17.9% in the paclitaxel-coated balloon group vs 28.6% in the uncoated balloon group, meeting the criteria for superiority (hazard ratio [HR], 0.59 [95% CI, 0.42-0.84]; 2-sided P = .003). Target lesion revascularization (13.0% vs 24.7%; HR, 0.50 [95% CI, 0.34-0.74]; P = .001) and target vessel-related myocardial infarction (5.8% vs 11.1%; HR, 0.51 [95% CI, 0.28-0.92]; P = .02) occurred less frequently among patients treated with paclitaxel-coated balloon. The rate of cardiac death was 2.9% vs 1.6% (HR, 1.75 [95% CI, 0.49-6.28]; P = .38) in the coated vs uncoated balloon groups, respectively. Conclusions and Relevance: Among patients undergoing coronary angioplasty for in-stent restenosis, a paclitaxel-coated balloon was superior to an uncoated balloon with respect to the composite end point of target lesion failure. Paclitaxel-coated balloons are an effective treatment option for patients with coronary in-stent restenosis. Trial Registration: ClinicalTrials.gov Identifier: NCT04647253.


Asunto(s)
Reestenosis Coronaria , Infarto del Miocardio , Femenino , Humanos , Anciano , Paclitaxel , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia , Stents , Resultado del Tratamiento , Muerte
2.
Circ J ; 87(2): 287-295, 2023 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-36450540

RESUMEN

BACKGROUND: Drug-coated balloons (DCB) have shown promising results for the treatment of in-stent restenosis (ISR) and small vessel disease (SVD). However, data comparing the treatment efficacy of different DCBs are limited.Methods and Results: AGENT Japan is a prospective randomized controlled trial that compares the Agent balloon coated with a low-dose formulation of paclitaxel (2 µg/mm2) to the SeQuent Please paclitaxel-coated balloon (3 µg/mm2) for the treatment of SVD. Patients with target lesion length ≤28 mm and reference diameter between ≥2.00 and <3.00 mm were randomized 2 : 1 for treatment with Agent (n=101) or SeQuent Please (n=49). This trial also includes a separate single-arm substudy evaluating the clinical safety and effectiveness of Agent in patients with ISR. The primary endpoint of 6-month target lesion failure (TLF) was observed in 3.0% of Agent and 0.0% of SeQuent Please patients (difference=3.0%; 97.5% upper confidence bound [UCB]=9.57%, which is less than the prespecified margin of 13.2%; Pnon-inferiority=0.0012). There were no deaths or thrombosis, and angiographic and quality-of-life outcomes were comparable between groups. The AGENT Japan ISR substudy (n=30) primary endpoint was met because the one-sided 97.5% UCB for 6-month TLF (3.3%) was significantly less than the study success criterion of 15.1% (97.5% UCB=9.8%; P<0.0001). CONCLUSIONS: Data from this study demonstrate good clinical outcomes with the Agent DCB when used to treat patients with SVD or ISR.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Paclitaxel , Humanos , Angioplastia Coronaria con Balón/efectos adversos , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos/efectos adversos , Paclitaxel/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 99(2): 373-380, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34051049

RESUMEN

OBJECTIVES: The EVOLVE 48 study evaluated the safety and effectiveness of the SYNERGY 48 mm stent for the treatment of long lesions. BACKGROUND: Clinical evidence supporting the use of very long stents during percutaneous coronary intervention (PCI) is limited. The bioabsorbable polymer SYNERGY stent has shown good long-term data in a broad population of patients undergoing PCI. METHODS: Patients with lesion length >34- ≤44 mm and reference vessel diameter (RVD) ≥2.5- ≤ 4.0 mm were enrolled in this prospective, multicenter, single-arm study. The primary endpoint was 12-month target lesion failure (TLF; composite of target lesion revascularization [TLR], target-vessel myocardial infarction [TV-MI], or cardiac death) compared to a prespecified performance goal (PG). RESULTS: A total of 100 patients with mean lesion length of 35.34 ± 7.15 mm (26 patients with lesion length > 40 mm) and mean RVD 2.72 ± 0.44 mm were enrolled. Moderate to severe calcification was present in 30% of the patients and 89% had pre-TIMI flow grade 3. The rates of technical and clinical procedural success were 100%. One-year TLF was observed in 4.1% patients compared to a prespecified PG of 19.5% (95% upper confidence bound = 9.1%; p < 0.0001). Cardiac death and TLR were each observed in one patient, and TV-MI in two patients treated with SYNERGY 48 mm stent. Between the 1-2-year timeframe, TV-MI occurred in one additional patient. None of the patients experienced a definite or probable stent thrombosis through 2 years. CONCLUSIONS: PCI of long coronary lesions with the 48 mm SYNERGY stent demonstrated good procedural and clinical outcomes through 2 years, supporting its clinical safety and efficacy.


Asunto(s)
Fármacos Cardiovasculares , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Implantes Absorbibles , Fármacos Cardiovasculares/efectos adversos , Everolimus/efectos adversos , Humanos , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Estudios Prospectivos , Diseño de Prótesis , Sirolimus , Stents , Resultado del Tratamiento
4.
Am Heart J ; 241: 101-107, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34314727

RESUMEN

BACKGROUND: Drug-coated balloon (DCB) technology was developed as an alternative treatment for obstructive coronary artery disease (CAD) and in-stent restenosis (ISR). Management of coronary ISR is clinically challenging and frequently encountered in practice. The Agent DCB uses an inactive excipient to effectively deliver a targeted, therapeutic dose of paclitaxel to the vessel wall. STUDY DESIGN: AGENT IDE is a prospective, multicenter, randomized controlled trial to evaluate superiority of the Agent DCB to balloon angioplasty in treating patients with ISR. A total of 480 patients with ISR of a previously treated lesion length <26 mm and reference vessel diameter >2.0 mm to ≤4.0 mm will be initially randomized. Subjects presenting with recent myocardial infarction (MI), complex lesions, or thrombus in the target vessel will be excluded. An adaptive group sequential design with one formal interim analysis for sample size re-estimation will be conducted, and the sample size may be increased to a maximum of 600 subjects. The primary endpoint is the rate of 12-month target lesion failure (TLF; composite of any ischemia-driven revascularization of the target lesion (TLR), target vessel related MI, or cardiac death) and will be tested for superiority in the test arm against the control. Functional status and general health-related quality of life will be measured by changes in the EQ-5D scores. Subjects will be followed for 5 years following the index procedure. CONCLUSION: This study will prospectively evaluate the safety and efficacy of Agent DCB in patients treated for coronary ISR.


Asunto(s)
Angioplastia Coronaria con Balón , Catéteres Cardíacos/clasificación , Enfermedad de la Arteria Coronaria/cirugía , Reestenosis Coronaria , Paclitaxel/farmacología , Reoperación , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/instrumentación , Angioplastia Coronaria con Balón/métodos , Antineoplásicos Fitogénicos/farmacología , Materiales Biocompatibles Revestidos/farmacología , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/etiología , Reestenosis Coronaria/cirugía , Stents Liberadores de Fármacos/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Multicéntricos como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto , Reoperación/efectos adversos , Reoperación/instrumentación , Reoperación/métodos
5.
Gynecol Oncol ; 158(1): 188-193, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32456991

RESUMEN

The purpose of this paper is to review the surgical care related to training in gynecologic oncology, from past, present and future perspectives. A marked decline in the incidence of cervical cancer as well as improvements in radiation therapy have led to a reduction in the numbers of radical hysterectomies and exenterations being performed. Utilization of neoadjuvant chemotherapy is reducing the extent of cytoreductive operations, including intestinal surgery. The incorporation of sentinel lymphatic mapping has reduced the number of pelvic, paraaortic and inguinal lymphadenectomies being performed. Coupled with these changes are other factors limiting time for surgical training including an explosion in targeted anticancer therapies and more individualized options beyond simple cytotoxic therapy. With what is likely to be a sustained impact on training, gynecologic oncologists will still provide a broad range of care for women with gynecologic cancer but may be quite limited in surgical scope and rely on colleagues from other surgical disciplines. Enhancement of surgical training by off-service rotations, simulation, attending advanced surgical training courses and/or a longer duration of training are currently incorporated into some programs. Programs must ensure that fellows take full advantage of the clinical materials available, particularly those related to the potential deficiencies described. Changing required research training to an additional elective year could also be considered. Based on the perspectives noted, we believe it is time for our subspecialty to reevaluate its scope of surgical training and practice.


Asunto(s)
Neoplasias de los Genitales Femeninos/cirugía , Procedimientos Quirúrgicos Ginecológicos/educación , Femenino , Procedimientos Quirúrgicos Ginecológicos/historia , Procedimientos Quirúrgicos Ginecológicos/métodos , Historia del Siglo XIX , Historia del Siglo XX , Historia del Siglo XXI , Humanos
6.
Catheter Cardiovasc Interv ; 94(3): 334-341, 2019 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-30597737

RESUMEN

BACKGROUND: The ION Study assessed clinical outcomes for the thin-strut, ION™ (TAXUS Element) Paclitaxel-Eluting Platinum Chromium Coronary Stent System (Boston Scientific, Marlborough, MA) in unselected patients. METHODS: This prospective, open-label registry enrolled the first 1,120 consenting patients treated with the ION stent without clinical or angiographic inclusion criteria at 40 clinical sites. Follow-up was at discharge, 30 days, 180 days, 1 and 2 years. The primary endpoint, the 1-year rate of cardiac death or MI (CD/MI) in PERSEUS-like patients (i.e., patients similar to those enrolled in PERSEUS, the pivotal approval trial), was tested in patients pooled from the ION study (N = 316), the European TAXUS Element post-approval registry (TE-PROVE; N = 306 PERSEUS-like patients), and the PERSEUS WH/SV populations (N = 1,166); and then compared with a prespecified performance goal. Additional outcomes were examined in the overall ION patient population. RESULTS: A total of 1,111 (out of 1,120) enrolled patients received a study stent. Most patients were male (70%) and mean age was 64 years. At 1 year, the primary endpoint of CD/MI occurred in 2.1% (6/292) of PERSEUS-like patients in ION, and 2.3% (40/1,729) of patients in the combined analysis. The upper one-sided 95% confidence interval for the combined analysis was 2.9%, which was significantly less than the performance goal of 7.6% (P < 0.001). Within patients enrolled in the ION study (N = 1,111), the rate of CD/MI was 4.5% at 1 year and 7.5% at 2 years. Definite/probable stent thrombosis occurred in 2.1% of patients at 1 year and 2.5% at 2 years. CONCLUSIONS: The results of the ION Study confirm the mid-term safety and effectiveness of the ION stent for the treatment of coronary artery disease in everyday clinical practice.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Cromo , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Platino (Metal) , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Vigilancia de Productos Comercializados , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
7.
Catheter Cardiovasc Interv ; 94(1): 82-90, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-30666784

RESUMEN

OBJECTIVE: We evaluated 1-year outcomes after platinum chromium everolimus-eluting stents (PtCr-EES) in small versus non-small coronary arteries within a large, diverse sample of men, women, and minorities. BACKGROUND: There exists limited outcomes data on the use of second-generation drug-eluting stent to treat small diameter coronary arteries. METHODS: We pooled patients from the PLATINUM Diversity and PROMUS Element Plus stent registries. Small-vessel percutaneous coronary intervention (SV-PCI) was defined as ≥1 target lesion with reference vessel diameter (RVD) ≤2.5 mm. Endpoints included major adverse cardiac event (MACE; death, myocardial infarction [MI] or target vessel revascularization [TVR]), target vessel failure (TVF; death related to the target vessel, target vessel MI or TVR) and definite/probable stent thrombosis (ST). Multivariable Cox regression was used to risk-adjust outcomes. RESULTS: We included 4,155/4,182 (99%) patients with available RVD, of which 1,607 (39%) underwent small-vessel PCI. SV-PCI was not associated with increased MACE (adjHR 1.02; 95%CI 0.81-1.30) or TVF (adjHR 1.07; 95%CI 0.82-1.39). MI risk was lower in white men compared to women and minorities, both in the setting of SV-PCI (adjHR 0.41; 95%CI 0.23-0.74 and adjHR 0.39; 95%CI 0.20-0.75, respectively) and for non-SV-PCI (adjHR 0.61; 95%CI 0.38-0.99 and adjHR 0.45; 95%CI 0.27-0.74, respectively). There was no significant interaction between RVD and sex or minority status for any endpoint. CONCLUSION: In a large diverse contemporary PCI outcomes database, SV-PCI with PtCr-EES was not associated with increased MACE or TVR and did not account for the increased MI risk noted in women and minorities compared to white men.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Cromo , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Disparidades en el Estado de Salud , Salud de las Minorías , Intervención Coronaria Percutánea/instrumentación , Platino (Metal) , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/etnología , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etnología , Trombosis Coronaria/mortalidad , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etnología , Infarto del Miocardio/mortalidad , Estudios Observacionales como Asunto , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Factores Raciales , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores Sexuales , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología
8.
Neuromodulation ; 20(6): 582-588, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28370724

RESUMEN

OBJECTIVE: Concordant paresthesia coverage is an independent predictor of pain relief following spinal cord stimulation (SCS). Using aggregate data, our objective is to produce a map of paresthesia coverage as a function of electrode location in SCS. METHODS: This retrospective analysis used x-rays, SCS programming data, and paresthesia coverage maps from the EMPOWER registry of SCS implants for chronic neuropathic pain. Spinal level of dorsal column stimulation was determined by x-ray adjudication and active cathodes in patient programs. Likelihood of paresthesia coverage was determined as a function of stimulating electrode location. Segments of paresthesia coverage were grouped anatomically. Fisher's exact test was used to identify significant differences in likelihood of paresthesia coverage as a function of spinal stimulation level. RESULTS: In the 178 patients analyzed, the most prevalent areas of paresthesia coverage were buttocks, anterior and posterior thigh (each 98%), and low back (94%). Unwanted paresthesia at the ribs occurred in 8% of patients. There were significant differences in the likelihood of achieving paresthesia, with higher thoracic levels (T5, T6, and T7) more likely to achieve low back coverage but also more likely to introduce paresthesia felt at the ribs. Higher levels in the thoracic spine were associated with greater coverage of the buttocks, back, and thigh, and with lesser coverage of the leg and foot. CONCLUSION: This paresthesia atlas uses real-world, aggregate data to determine likelihood of paresthesia coverage as a function of stimulating electrode location. It represents an application of "big data" techniques, and a step toward achieving personalized SCS therapy tailored to the individual's chronic pain.


Asunto(s)
Atlas como Asunto , Electrodos Implantados , Parestesia/terapia , Estimulación de la Médula Espinal/instrumentación , Estimulación de la Médula Espinal/métodos , Adulto , Anciano , Electrodos Implantados/normas , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Parestesia/diagnóstico , Sistema de Registros , Estudios Retrospectivos , Estimulación de la Médula Espinal/normas
9.
Catheter Cardiovasc Interv ; 86(6): 994-1001, 2015 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-25678402

RESUMEN

BACKGROUND: The TAXUS Element (ION) platinum chromium paclitaxel-eluting stent (PtCr-PES) incorporates a thin (81 µm) strut design with a similar polymer and drug dose density as prior PES. The pivotal PERSEUS trial program consisted of two studies: PERSEUS Workhorse (WH) and PERSEUS Small Vessel (SV). The PERSEUS WH trial demonstrated the PtCr-PES to be non-inferior to the predicate TAXUS Express PES (TE-PES) for target lesion failure (TLF) at 1 year and in-segment angiographic percent diameter stenosis at 9 months. The PERSEUS SV trial demonstrated the PtCr-PES to be superior to a historical bare metal stent (BMS) for angiographic late lumen loss at 9 months. Long-term (5-year) clinical outcomes following PtCr-PES have not been previously reported. METHODS: PERSEUS WH was a prospective, Bayesian, 3:1 randomized (PtCr-PES vs. TE-PES) trial in patients with lesion length ≤28 mm and vessel diameter ≥2.75 to ≤4.0 mm. PERSEUS SV was a prospective, single-arm trial in patients with lesion length ≤20 mm and vessel diameter ≥2.25 to <2.75 mm comparing PtCr-PES to a matched historical BMS control. RESULTS: Among randomized subjects in the PERSEUS WH study, clinical event rates at 5 years were similar between treatment groups, including TLF (12.9% TE-PES vs. 12.1% PtCr-PES; P = 0.66). In the PERSEUS SV study, 5-year rates of MACE, and TLF were significantly lower for PtCr-PES (vs. BMS) following adjustment for baseline characteristics and were primarily due to lower target lesion revascularization rates (27.2% BMS vs. 14.9% PtCr-PES; P = 0.049). CONCLUSIONS: At 5 years, the PtCr-PES provides efficacy and safety that is comparable to the TE-PES and superior efficacy with similar safety when compared with BMS in smaller caliber vessels. Cumulative stent thrombosis rates remained low and similar through 5 years for both DES platforms.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Enfermedad Coronaria/terapia , Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Diseño de Prótesis/métodos , Adulto , Anciano , Angioplastia Coronaria con Balón/mortalidad , Teorema de Bayes , Cromo/química , Angiografía Coronaria/métodos , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/mortalidad , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Selección de Paciente , Platino (Metal)/química , Estudios Prospectivos , Falla de Prótesis , Medición de Riesgo , Índice de Severidad de la Enfermedad , Método Simple Ciego , Estadísticas no Paramétricas , Tasa de Supervivencia , Taxus , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
10.
Eur Heart J ; 35(40): 2821-30, 2014 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-24849105

RESUMEN

AIMS: Coronary artery bypass grafting (CABG) has been considered the standard of care for patients with three-vessel disease (3VD), but long-term comparative results from randomized trials of CABG vs. percutaneous coronary intervention (PCI) using drug-eluting stents (DES) remain limited. METHODS AND RESULTS: Patients with de novo 3VD or left main disease were randomly assigned to PCI with the paclitaxel-eluting first-generation stent or CABG in the SYNTAX trial. This pre-specified analysis presents the 5-year outcomes of patients with 3VD (n = 1095). The rate of major adverse cardiac and cerebrovascular events (MACCE) was significantly higher in patients with PCI compared with CABG (37.5 vs. 24.2%, respectively; P < 0.001). Percutaneous coronary intervention as opposed to CABG resulted in significantly higher rates of the composite of death/stroke/myocardial infarction (MI) (22.0 vs. 14.0%, respectively; P < 0.001), all-cause death (14.6 vs. 9.2%, respectively; P = 0.006), MI (9.2 vs. 4.0%, respectively; P = 0.001), and repeat revascularization (25.4 vs. 12.6%, respectively; P < 0.001); however, stroke was similar between groups at 5 years (3.0 vs. 3.5%, respectively; P = 0.66). Results were dependent on lesion complexity (P for interaction = 0.12); in patients with a low (0-22) SYNTAX score, PCI vs. CABG resulted in similar rates of MACCE (33.3% vs. 26.8%, respectively; P = 0.21) but significantly more repeat revascularization (25.4% vs. 12.6%, respectively; P = 0.038), while in intermediate (23-32) or high (≥ 33) SYNTAX score terciles, CABG demonstrated clear superiority in terms of MACCE, death, MI, and repeat revascularization. Differences in MACCE between PCI and CABG were larger in diabetics [hazard ratio (HR) = 2.30] than non-diabetics (HR = 1.51), although the P for interaction failed to reach significance for MACCE (P for interaction = 0.095) or any of the other endpoints. CONCLUSION: Five-year results of patients with 3VD treated with CABG or PCI using the first-generation paclitaxel-eluting DES suggest that CABG should remain the standard of care as it resulted in significantly lower rates of death, MI, and repeat revascularization, while stroke rates were similar. For patients with low SYNTAX scores, PCI is an acceptable revascularization strategy, although at a price of significantly higher rates of repeat revascularization. CLINICAL TRIAL REGISTRATION: NCT00114972.


Asunto(s)
Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea/métodos , Enfermedad de la Arteria Coronaria/mortalidad , Angiopatías Diabéticas/tratamiento farmacológico , Angiopatías Diabéticas/mortalidad , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Revascularización Miocárdica/métodos , Revascularización Miocárdica/mortalidad , Estudios Prospectivos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad , Resultado del Tratamiento
11.
Cardiovasc Interv Ther ; 39(1): 47-56, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37642826

RESUMEN

The Agent device consists of a semi-compliant balloon catheter, which is coated with a therapeutic low-dose formulation of paclitaxel (2 µg/mm2) blended with an inactive excipient acetyl-tri-n-butyl citrate (ATBC). AGENT Japan SV is a randomized controlled study that enrolled 150 patients from 14 Japanese sites treated with Agent or SeQuent Please paclitaxel-coated balloon. This study also includes a single-arm substudy evaluating the safety and effectiveness of Agent in patients with in-stent restenosis (ISR). Patients with a single de novo native lesion (lesion length ≤ 28 mm and reference diameter ≥ 2.00 to < 3.00 mm) were randomized 2:1 to receive either Agent (n = 101) or SeQuent Please (n = 49). The ISR substudy enrolled 30 patients with lesion length ≤ 28 mm and reference diameter ≥ 2.00 to ≤ 4.00 mm. In the SV RCT, target lesion failure (TLF) at 1 year occurred in four patients treated with Agent (4.0%) versus one patient with SeQuent Please (2.0%; P = 1.00). None of the patients in either treatment arm died. There were no significant differences in the rates of myocardial infarction, target lesion revascularization and target lesion thrombosis through 1 year. In the ISR substudy, the 1-year rates of TLF and target lesion thrombosis were 6.7% and 0.0%, respectively. These data support the safety and effectiveness of the Agent paclitaxel-coated balloon in patients with small vessels and ISR.


Asunto(s)
Angioplastia Coronaria con Balón , Reestenosis Coronaria , Trombosis , Humanos , Paclitaxel/farmacología , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia , Resultado del Tratamiento , Factores de Riesgo , Trombosis/etiología , Materiales Biocompatibles Revestidos
12.
J Interv Cardiol ; 26(1): 49-57, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22988961

RESUMEN

OBJECTIVES: To assess the influence of race on long-term outcomes following percutaneous coronary intervention (PCI) with paclitaxel-eluting stents (PES). BACKGROUND: Data on the influence of race on long-term outcomes following PCI with drug-eluting stents are limited because of severe underrepresentation of minority populations in randomized trials. METHODS: We compared 5-year outcomes of 2,301 whites, 127 blacks, and 169 Asians treated with PES in the TAXUS IV, V, and ATLAS trials. Outcomes were adjusted using a propensity score logistic regression model with 1:4 matching. RESULTS: Blacks were more likely than whites to be female, have a history of hypertension, diabetes mellitus, congestive heart failure, and stroke, but were less likely to have prior coronary artery disease. Compared with whites, Asians were younger, more likely to be male, have stable angina, and left anterior descending disease, and less likely to have silent ischemia, previous coronary artery bypass surgery, prior coronary artery disease, diabetes mellitus, peripheral vascular disease, and to receive glycoprotein IIb/IIIa inhibitors. Despite higher antiplatelet compliance, the adjusted 5-year rates of myocardial infarction (15.4% vs. 5.4%, P < 0.001) and stent thrombosis (5.6% vs. 1.1%, P = 0.002) were higher in blacks than whites. Despite lower antiplatelet compliance, Asians had no differences in myocardial infarction and stent thrombosis compared with whites. Mortality and revascularization rates were similar between the three groups. CONCLUSIONS: The long-term risk of major thrombotic events after PCI with PES was higher in blacks, but not Asians, compared with whites. The mechanisms underlying these racial differences warrant further investigation.


Asunto(s)
Cardiotónicos/administración & dosificación , Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Intervención Coronaria Percutánea , Grupos Raciales/estadística & datos numéricos , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Ensayos Clínicos Controlados Aleatorios como Asunto , Trombosis/epidemiología
13.
JMIR Form Res ; 7: e45061, 2023 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-37115658

RESUMEN

BACKGROUND: African American individuals are at a higher risk of premature death from cardiovascular diseases than White American individuals, with disproportionate attributable risk from uncontrolled hypertension. Given their high use among African American individuals, mobile technologies, including smartphones, show promise in increasing reliable health information access. Culturally tailored mobile health (mHealth) interventions may promote hypertension self-management among this population. OBJECTIVE: This formative study aimed to assess the feasibility of integrating an innovative mHealth intervention into clinical and community settings to improve blood pressure (BP) control among African American patients. METHODS: A mixed methods study of African American patients with uncontrolled hypertension was conducted over 2 consecutive phases. In phase 1, patients and clinicians from 2 federally qualified health centers (FQHCs) in the Minneapolis-St Paul, Minnesota area, provided input through focus groups to refine an existing culturally tailored mHealth app (Fostering African-American Improvement in Total Health! [FAITH!] App) for promoting hypertension self-management among African American patients with uncontrolled hypertension (renamed as FAITH! Hypertension App). Phase 2 was a single-arm pre-post intervention pilot study assessing feasibility and patient satisfaction. Patients receiving care at an FQHC participated in a 10-week intervention using the FAITH! Hypertension App synchronized with a wireless BP monitor and community health worker (CHW) support to address social determinants of health-related social needs. The multimedia app consisted of a 10-module educational series focused on hypertension and cardiovascular risk factors with interactive self-assessments, medication and BP self-monitoring, and social networking. Primary outcomes were feasibility (app engagement and satisfaction) and preliminary efficacy (change in BP) at an immediate postintervention assessment. RESULTS: In phase 1, thirteen African American patients (n=9, 69% aged ≥50 years and n=10, 77% women) and 16 clinicians (n=11, 69% aged ≥50 years; n=14, 88% women; and n=10, 63% African American) participated in focus groups. Their feedback informed app modifications, including the addition of BP and medication tracking, BP self-care task reminders, and culturally sensitive contexts. In phase 2, sixteen African American patients were enrolled (mean age 52.6, SD 12.3 years; 12/16, 75% women). Overall, 38% (6/16) completed ≥50% of the 10 education modules, and 44% (7/16) completed the postintervention assessment. These patients rated the intervention a 9 (out of 10) on its helpfulness in hypertension self-management. Qualitative data revealed that they viewed the app as user-friendly, engaging, and informative, and CHWs were perceived as providing accountability and support. The mean systolic and diastolic BPs of the 7 patients decreased by 6.5 mm Hg (P=.15) and 2.8 mm Hg (P=.78), respectively, at the immediate postintervention assessment. CONCLUSIONS: A culturally tailored mHealth app reinforced by CHW support may improve hypertension self-management among underresourced African American individuals receiving care at FQHCs. A future randomized efficacy trial of this intervention is warranted. TRIAL REGISTRATION: ClinicalTrials.gov NCT04554147; https://clinicaltrials.gov/ct2/show/NCT04554147.

14.
Artículo en Inglés | MEDLINE | ID: mdl-38469035

RESUMEN

Background: How diabetes mellitus (DM), race/ethnicity, and sex impact ischemic events following coronary artery stent procedures is unknown. Methods: Using the PLATINUM Diversity and PROMUS Element Plus Post-Approval Pooled Study (N = 4184), we examined the impact of race/ethnicity, sex, and DM on coronary stent outcomes. Primary outcome was 1-year major adverse cardiac events (MACE) (MACE composite: death, myocardial infarction [MI], and target vessel revascularization). Results: The study sample included 1437 diabetic patients (501 White men, 470 White women, 246 minority men, 220 minority women) and 2641 patients without medically treated DM (561 minority, 1090 women). Mean age (years) ranged from 61 in minority men to 65 in White women. Diabetic patients had a higher prevalence of atherosclerotic risk factors and comorbidities. Diabetic minority women (DMW; 70% Black, 27% Hispanic) had similar atherosclerotic risk factors to other diabetics, but experienced higher 1-year MACE (14.4% vs 7.5%, P <.01) and MI (4.3% vs 1.6%, P <.01) rates compared with patients without medically treated DM. No other diabetic cohort (White men, White women, minority men) showed an increased risk of MACE vs patients without medically treated DM. The incremental risk of MACE in DMW was associated with insulin use and persisted after risk adjustment (adjusted odds ratio 1.6 vs patients without medically treated DM; 95% CI, 1.0-2.5). Independent predictors of 1-year MACE included insulin use, hyperlipidemia, renal disease, and prior MI. Conclusions: DMW face the highest risk of ischemic events following coronary stenting, driven, in part, by insulin use. Aggressive secondary prevention and strict glycemic control are imperative in this cohort, and further research is warranted to elucidate the biologic mechanisms underpinning these observations. Clinical Trial Registration: NCT02240810 (http://clinicaltrials.gov/).

15.
J Interv Cardiol ; 25(4): 353-63, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22612261

RESUMEN

BACKGROUND: With the changing health care environment, cost effectiveness is an important adjunct to clinical investigation when assessing new medical devices. This study presents an economic model to evaluate cost effectiveness of coronary stents. METHODS: Markov modeling was developed comparing total costs (Medicare payer perspective) between TAXUS Liberté and TAXUS Express based on 3-year clinical outcomes from the TAXUS ATLAS Small Vessel and Long Lesion trials. RESULTS: The TAXUS Liberté 2.25-mm stent provided cost savings relative to TAXUS Express from a payer perspective ($17,605 vs. $20,281), driven by reduced target vessel revascularization (0.16 events/patient vs. 0.33 events/patient). In probabilistic sensitivity analyses, TAXUS Liberté was less costly with fewer major adverse cardiac events in over 99% of parameter sets. The TAXUS Liberté Long (38 mm) stent was cost neutral relative to TAXUS Express from a payer perspective ($18,545 vs. $18,551) with fewer myocardial infarctions and cardiac deaths. Accounting for angiography-driven revascularizations, TAXUS Liberté 2.25 mm still provided cost savings relative to TAXUS Express ($16,822 vs. $19,139), although TAXUS Liberté Long was more expensive than TAXUS Express ($17,886 vs. $17,652). From a hospital perspective, TAXUS Liberté Long provided cost savings up to a price premium of $671/stent, driven by fewer stents employed per patient. CONCLUSIONS: This analysis confirms the utility of economic modeling in assessing new stent platforms. TAXUS Liberté 2.25 mm is economically dominant relative to TAXUS Express when treating small vessels. TAXUS Liberté Long is cost neutral to modestly more costly than TAXUS Express 2.25 mm from a payer perspective.


Asunto(s)
Enfermedad de la Arteria Coronaria/economía , Stents Liberadores de Fármacos/economía , Modelos Económicos , Antineoplásicos Fitogénicos/uso terapéutico , Enfermedad de la Arteria Coronaria/terapia , Análisis Costo-Beneficio , Stents Liberadores de Fármacos/efectos adversos , Humanos , Cadenas de Markov , Paclitaxel/uso terapéutico , Estudios Retrospectivos , Resultado del Tratamiento
16.
Am J Dermatopathol ; 34(1): 104-9, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22262361

RESUMEN

Hidradenoma papilliferum of the anogenital region was previously believed to originate from apocrine glands but has recently been accepted as originating from anogenital mammary-like glands. We describe a case of hidradenoma papilliferum with mixed features of syringocystadenoma papilliferum and mammary-like glands from the left labia majora of a 25-year-old woman. Histopathologically, the lesion showed an epithelial lining with apocrine secretion, and like syringocystadenoma papilliferum, the lesion extended from the epithelium as invaginations into the dermis. Adjacent to this lesion were ductal and glandular structures resembling normal mammary tissue. This review of the literature highlights the heterogeneity and complexity of lesions arising from anogenital mammary-like glands, and this case serves as further documentation of the association between anogenital mammary-like glands and hidradenoma papilliferum.


Asunto(s)
Adenoma de las Glándulas Sudoríparas/patología , Glándulas Apocrinas/patología , Neoplasias de las Glándulas Sudoríparas/patología , Adenoma de las Glándulas Sudoríparas/metabolismo , Adenoma de las Glándulas Sudoríparas/cirugía , Adulto , Canal Anal/metabolismo , Canal Anal/patología , Glándulas Apocrinas/metabolismo , Biomarcadores de Tumor/metabolismo , Dermis/metabolismo , Dermis/patología , Femenino , Genitales Femeninos/metabolismo , Genitales Femeninos/patología , Genitales Femeninos/cirugía , Humanos , Hiperpigmentación/metabolismo , Hiperpigmentación/patología , Glándulas Mamarias Humanas/metabolismo , Glándulas Mamarias Humanas/patología , Neoplasias de las Glándulas Sudoríparas/metabolismo , Neoplasias de las Glándulas Sudoríparas/cirugía , Resultado del Tratamiento
17.
Int Wound J ; 9(3): 303-10, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22099530

RESUMEN

Pre-tibial lacerations are complex wounds affecting a primarily aged population, with poor healing and a potentially significant impact on social well-being. Management of these wounds has changed little in 20 years, despite significant advances in wound care. A retrospective observational study was undertaken to observe current wound care practice and to assess the effect of various medical factors on wound healing time on 24 elderly patients throughout their wound journey. Wound length was found to be substantively and significantly associated with wound healing time, with a reduction in instantaneous healing rate of about 30% for every increase of 1 cm in wound length. Hence, longer wounds are associated with longer wound healing times. Prescription of several categories of drugs, including those for ischaemic heart disease (IHD), hypertension, respiratory disease or asthma; and the age of the patient were not significantly associated with wound healing times, although substantive significance could be inferred in the case of prescription for IHD and asthma. Despite the small sample size, this study identified a clear association between healing and length of wound. Neither the comorbidities nor prescriptions explored showed any significant association although some seem to be more prevalent in this patient group. The study also highlighted other issues that require further exploration including the social and economic impact of these wounds.


Asunto(s)
Laceraciones/patología , Cicatrización de Heridas , Anciano de 80 o más Años , Vendajes , Desbridamiento , Femenino , Estudios de Seguimiento , Humanos , Laceraciones/epidemiología , Laceraciones/terapia , Masculino , Prevalencia , Estudios Retrospectivos , Muslo , Factores de Tiempo , Resultado del Tratamiento , Reino Unido/epidemiología
18.
Circ J ; 75(5): 1120-9, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21467655

RESUMEN

BACKGROUND: The long-term impact of treating de novo coronary lesions in native vessels and challenging small vessel and long lesion subsets with TAXUS Liberté stents is unknown. This report examines the 3-year efficacy and safety from the TAXUS ATLAS program. METHODS AND RESULTS: TAXUS ATLAS WH, Small Vessel, and Long Lesion are non-randomized studies comparing TAXUS Liberté (n = 871), TAXUS Liberté 2.25 mm (n = 261), and TAXUS Liberté 38 mm (n = 150) stents, respectively, to case-matched TAXUS Express historical controls. TAXUS Liberté demonstrated comparable 3-year rates of major adverse cardiac events (19.0% vs. 20.2%, P = 0.51) in de novo lesions, reduced target lesion revascularization (TLR, 10.0% vs. 22.1%, P = 0.008) in small vessels, and reduced myocardial infarction (MI, 2.9% vs. 10.4%; P = 0.01) and stent thrombosis (ST, 0.0% vs. 3.9%, P = 0.03) in long lesions vs. TAXUS Express. After propensity score adjustment, no statistically significant effect of TAXUS Liberté on TLR (9.7% vs. 16.9%, P = 0.12) in small vessels or MI (2.9% vs. 7.9%, P = 0.05) in long lesions was noted, although reduced ST (0.0% vs. 2.7%, P = 0.02) remained in long lesions. Multivariate analyses demonstrated that TAXUS Liberté treatment significantly reduced TLR by 66% in small vessels, and MI by 75% in long lesions, vs. TAXUS Express. CONCLUSIONS: TAXUS Liberté suggests durable 3-year effectiveness in reducing restenosis and improved clinical outcomes in small vessels and long lesions compared with TAXUS Express.


Asunto(s)
Stents , Humanos , Taxus
20.
Clin Med (Lond) ; 20(2): 212-214, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32188661

RESUMEN

We report a case of a 72-year-old woman who presented with ST-elevation myocardial infarction (STEMI). However, coronary angiography showed unobstructed arteries while echocardiography (ECHO) showed severe left ventricular (LV) apical hypokinesia with ejection fraction (EF) of 25-30%. Seven months later she presented with a transient ischaemic attack and a repeat ECHO showed a normal EF.A few months later, she was diagnosed with breast cancer and as part of staging procedure, an incidental left adrenal mass was identified. This was biochemically confirmed as phaeochromocytoma (PY) and she underwent laparoscopic adrenalectomy.PY is a rare catecholamine secreting tumour arising from adrenomedullary chromaffin cells. Excessive catecholamine-induced stimulation can present as transient, reversible cardiomyopathy similar to Takotsubo cardiomyopathy and cerebrovascular events. The diagnosis of PY is often delayed but it is important to recognize PY as a cause of reversible cardiomyopathy. Early intervention is essential to improve mortality from cardiovascular and cerebrovascular complications.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales , Feocromocitoma , Cardiomiopatía de Takotsubo , Neoplasias de las Glándulas Suprarrenales/complicaciones , Neoplasias de las Glándulas Suprarrenales/diagnóstico , Anciano , Angiografía Coronaria , Femenino , Ventrículos Cardíacos , Humanos , Feocromocitoma/complicaciones , Feocromocitoma/diagnóstico , Cardiomiopatía de Takotsubo/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA