Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
AJR Am J Roentgenol ; 220(3): 358-370, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36043610

RESUMEN

BACKGROUND. Targeted axillary lymph node dissection after neoadjuvant systemic therapy (NST) for breast cancer depends on identifying marked metastatic lymph nodes. However, ultrasound visualization of biopsy markers is challenging. OBJECTIVE. The purpose of our study was to identify biopsy markers that show actionable twinkling in cadaveric breast and to assess the association of actionable twinkling with markers' surface roughness. METHODS. Commercial breast biopsy markers were evaluated for twinkling artifact in various experimental conditions relating to scanning medium (solid gel phantom, ultrasound coupling gel, cadaveric breast), transducer (ML6-15, 9L, C1-6), and embedding material (present vs absent). Markers were assigned twinkling scores from 0 (confident in no twinkling) to 4 (confident in exuberant twinkling); a score of 3 or greater represented actionable twinkling (sufficient confidence to rely solely on twinkling for target localization). Markers were hierarchically advanced to evaluation with increasingly complex media if showing at least minimal twinkling for a given medium. A 3D coherence optical profiler measured marker surface roughness. Mixed-effects proportional odds regression models assessed associations between twinkling scores and transducer and embedding material; Wilcoxon rank sum test evaluated associations between actionable twinkling and surface roughness. RESULTS. Thirty-five markers (21 with embedding material) were evaluated. Ten markers without embedding material advanced to evaluation in cadaveric breast. Higher twinkling scores were associated with presence of embedding material (odds ratio [OR] = 5.05 in solid gel phantom, 9.84 in coupling gel) and transducer (using the C1-6 transducer as reference; 9L transducer: OR = 0.36, 0.83, and 0.04 in solid gel phantom, ultrasound coupling gel, and cadaveric breast; ML6-15 transducer: OR = 0.07, 0.18, and 0.00 respectively; post hoc p between 9L and ML6-15: p < .001, p = .02, and p = .04). In cadaveric breast, three markers (Cork, Professional Q, MRI [Flex]) exhibited actionable twinkling for two or more transducers; surface roughness was significantly higher for markers with than without actionable twinkling for C1-6 (median values: 0.97 vs 0.35, p = .02) and 9L (1.75 vs 0.36; p = .002) transducers. CONCLUSION. Certain breast biopsy markers exhibited actionable twinkling in cadaveric breast. Twinkling was observed with greater confidence for the C1-6 and 9L transducers than the ML6-15 transducer. Actionable twinkling was associated with higher marker surface roughness. CLINICAL IMPACT. Use of twinkling for marker detection could impact preoperative or intraoperative localization after NST.


Asunto(s)
Neoplasias de la Mama , Ultrasonografía Doppler en Color , Humanos , Femenino , Ultrasonografía Doppler en Color/métodos , Ultrasonografía , Fantasmas de Imagen , Artefactos , Cadáver , Biopsia
2.
J Biomech Eng ; 141(6): 61004-6100412, 2019 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-30874717

RESUMEN

Commercially available heart valves have many limitations, such as a lack of remodeling, risk of calcification, and thromboembolic problems. Many state-of-the-art tissue-engineered heart valves (TEHV) rely on recellularization to allow remodeling and transition to mechanical behavior of native tissues. Current in vitro testing is insufficient in characterizing a soon-to-be living valve due to this change in mechanical response; thus, it is imperative to understand the performance of an in situ valve. However, due to the complex in vivo environment, this is difficult to accomplish. Finite element (FE) analysis has become a standard tool for modeling mechanical behavior of heart valves; yet, research to date has mostly focused on commercial valves. The purpose of this study has been to evaluate the mechanical behavior of a TEHV material before and after 6 months of implantation in a rat subdermis model. This model allows the recellularization and remodeling potential of the material to be assessed via a simple and inexpensive means prior to more complex ovine orthotropic studies. Biaxial testing was utilized to evaluate the mechanical properties, and subsequently, constitutive model parameters were fit to the data to allow mechanical performance to be evaluated via FE analysis of a full cardiac cycle. Maximum principal stresses and strains from the leaflets and commissures were then analyzed. The results of this study demonstrate that the explanted tissues had reduced mechanical strength compared to the implants but were similar to the native tissues. For the FE models, this trend was continued with similar mechanical behavior in explant and native tissue groups and less compliant behavior in implant tissues. Histology demonstrated recellularization and remodeling although remodeled collagen had no clear directionality. In conclusion, we observed successful recellularization and remodeling of the tissue giving confidence to our TEHV material; however, the mechanical response indicates the additional remodeling would likely occur in the aortic/pulmonary position.

3.
J Magn Magn Mater ; 427: 100-104, 2017 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-28286359

RESUMEN

Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance.

4.
Tissue Eng Part A ; 29(15-16): 413-423, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37130041

RESUMEN

Recruitment of endothelial cells to cardiovascular device surfaces could solve issues of thrombosis, neointimal hyperplasia, and restenosis. Since current targeting strategies are often nonspecific, new technologies to allow for site-specific cell localization and capture in vivo are needed. The development of cytocompatible superparamagnetic iron oxide nanoparticles has allowed for the use of magnetism for cell targeting. In this study, a magnetic polyurethane (PU)-2205 stainless steel (2205-SS) nanofibrous composite biomaterial was developed through analysis of composite sheets and application to stent-grafts. The PU nanofibers provide strength and elasticity while the 2205-SS microparticles provide ferromagnetic properties. Sheets were electrospun at mass ratios of 0-4:1 (2205-SS:PU) and stent-grafts with magnetic or nonmagnetic stents were coated at the optimal ratio of 2:1. These composite materials were characterized by microscopy, mechanical testing, a sessile drop test, magnetic field measurement, magnetic cell capture assays, and cytocompatibility after 14 days of culturing with endothelial cells. Results of this study show that an optimal ratio of 2:1 2205-SS:PU results in a hydrophobic material that balanced mechanical and magnetic properties and was cytocompatible up to 14 days. Significant cell capture required a thicker material of 0.5 mm thickness. Stent-grafts fabricated from a magnetic coating and a magnetic stent demonstrated uniform cell capture throughout the device surface. This novel biomaterial exhibits a combination of mechanical and magnetic properties that enables magnetic capture of cells and other therapeutic agents for vascular and other tissue engineering applications.


Asunto(s)
Materiales Biocompatibles , Nanofibras , Materiales Biocompatibles/farmacología , Materiales Biocompatibles/química , Ingeniería de Tejidos , Nanofibras/química , Poliuretanos/farmacología , Células Endoteliales , Fenómenos Magnéticos , Materiales Biocompatibles Revestidos/química
5.
Brachytherapy ; 22(6): 761-768, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37652777

RESUMEN

PURPOSE: Suboptimal ultrasound conspicuity of the brachytherapy applicator can lead to inaccurate image reconstructions of the applicator resulting in decreased tumor control or increased normal tissue dose. This feasibility study aims to improve ultrasound conspicuity of high-dose rate (HDR) brachytherapy needles by modifying the surface of the needles to produce a color Doppler twinkling signature. MATERIALS AND METHODS: Surface modifications of standard 17-gauge titanium HDR brachytherapy needles included laser-scribing, application of polymethyl methacrylate (PMMA), and coating with a commercially available echogenic coating. Laser-scribing was performed with variable widths (0.1-1 mm) and depths (10-100 µm). The echogenic coating was applied with 3 different thicknesses (27, 40, and 64 µm). Unmodified and modified needles were imaged under B-mode and color Doppler ultrasound in phantom and cadaver, and the signal strength was recorded. RESULTS: Laser-scribed, PMMA-coated, and echogenic-coated brachytherapy needles produced a twinkling signature along the needle shaft on color Doppler ultrasound. Twinkling was observed with laser-scribe depths >20 µm and widths >0.1 mm and from echogenic coatings 40 µm and 64 µm thick. Twinkling was not observed with unmodified needles. The twinkling signature had a spectral composition with a uniform magnitude between the velocities of 2 to 16 cm/s. CONCLUSIONS: Color Doppler ultrasound of surface-modified brachytherapy applicators may improve applicator conspicuity aiding applicator placement and digitization. HDR brachytherapy needles may be modified to produce the twinkling signature via laser-scribing, PMMA rings, or applying an echogenic coating.


Asunto(s)
Braquiterapia , Masculino , Humanos , Braquiterapia/métodos , Polimetil Metacrilato , Próstata , Ultrasonografía , Agujas
6.
J Neural Eng ; 20(1)2023 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-36538815

RESUMEN

Objective. To modify off-the-shelf components to build a device for collecting electroencephalography (EEG) from macroelectrodes surrounded by large fluid access ports sampled by an integrated microperfusion system in order to establish a method for sampling brain interstitial fluid (ISF) at the site of stimulation or seizure activity with no bias for molecular size.Approach. Twenty-four 560µm diameter holes were ablated through the sheath surrounding one platinum-iridium macroelectrode of a standard Spencer depth electrode using a femtosecond UV laser. A syringe pump was converted to push-pull configuration and connected to the fluidics catheter of a commercially available microdialysis system. The fluidics were inserted into the lumen of the modified Spencer electrode with the microdialysis membrane removed, converting the system to open flow microperfusion. Electrical performance and analyte recovery were measured and parameters were systematically altered to improve performance. An optimized device was tested in the pig brain and unbiased quantitative mass spectrometry was used to characterize the perfusate collected from the peri-electrode brain in response to stimulation.Main results. Optimized parameters resulted in >70% recovery of 70 kDa dextran from a tissue analog. The optimized device was implanted in the cortex of a pig and perfusate was collected during four 60 min epochs. Following a baseline epoch, the macroelectrode surrounded by microperfusion ports was stimulated at 2 Hz (0.7 mA, 200µs pulse width). Following a post-stimulation epoch, the cortex near the electrode was stimulated with benzylpenicillin to induce epileptiform activity. Proteomic analysis of the perfusates revealed a unique inflammatory signature induced by electrical stimulation. This signature was not detected in bulk tissue ISF.Significance. A modified dual-sensing electrode that permits coincident detection of EEG and ISF at the site of epileptiform neural activity may reveal novel pathogenic mechanisms and therapeutic targets that are otherwise undetectable at the bulk tissue level.


Asunto(s)
Líquido Extracelular , Proteómica , Animales , Porcinos , Líquido Extracelular/química , Encéfalo , Electrodos , Electroencefalografía
7.
J Vis Exp ; (179)2022 01 06.
Artículo en Inglés | MEDLINE | ID: mdl-35068481

RESUMEN

The endothelium is a dynamic integrated structure that plays an important role in many physiological functions such as angiogenesis, hemostasis, inflammation, and homeostasis. The endothelium also plays an important role in pathophysiologies such as atherosclerosis, hypertension, and diabetes. Endothelial cells form the inner lining of blood and lymphatic vessels and display heterogeneity in structure and function. Various groups have evaluated the functionality of endothelial cells derived from human peripheral blood with a focus on endothelial progenitor cells derived from hematopoietic stem cells or mature blood outgrowth endothelial cells (or endothelial colony-forming cells). These cells provide an autologous resource for therapeutics and disease modeling. Xenogeneic cells may provide an alternative source of therapeutics due to their availability and homogeneity achieved by using genetically similar animals raised in similar conditions. Hence, a robust protocol for the isolation and expansion of highly proliferative blood outgrowth endothelial cells from porcine peripheral blood has been presented. These cells can be used for numerous applications such as cardiovascular tissue engineering, cell therapy, disease modeling, drug screening, studying endothelial cell biology, and in vitro co-cultures to investigate inflammatory and coagulation responses in xenotransplantation.


Asunto(s)
Aterosclerosis , Células Progenitoras Endoteliales , Animales , Coagulación Sanguínea , Tratamiento Basado en Trasplante de Células y Tejidos , Porcinos , Ingeniería de Tejidos/métodos
8.
Eur Radiol Exp ; 6(1): 26, 2022 06 17.
Artículo en Inglés | MEDLINE | ID: mdl-35711010

RESUMEN

Since its first description 25 years ago, color Doppler twinkling has been a compelling ultrasound feature in diagnosing urinary stones. While the fundamental cause of twinkling remains elusive, the distinctive twinkling signature is diagnostically valuable in clinical practice. It can be inferred that if an entity twinkles, it empirically has certain physical features. This work investigates a manipulable polymeric material, polymethyl methacrylate (PMMA), which twinkles and has measurable surface roughness and porosity that likely contribute to twinkling. Comparative investigation of these structural properties and of the twinkling signatures of breast biopsy markers made from PMMA and selected commercially available markers showed how twinkling can improve ultrasound detection of devices intentionally designed to twinkle. While this specific application of detecting breast biopsy markers by twinkling may provide a way to approach an unmet need in the care of patients with breast cancer, this work ultimately provides a platform from which the keys to unlocking the fundamental physics of twinkling can be rigorously explored.


Asunto(s)
Artefactos , Cálculos Renales , Biopsia , Humanos , Cálculos Renales/patología , Polimetil Metacrilato , Ultrasonografía Doppler en Color
9.
Ultrasound Med Biol ; 47(11): 3122-3134, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34412903

RESUMEN

In breast radiology, ultrasound detection of biopsy markers or clips for localization purposes is often challenging, especially in the axilla. The purpose of this research was to test the hypothesis that the surface roughness of biopsy clips would elicit a twinkling signature on color Doppler, making them more readily identifiable by ultrasound. Ultrasound color Doppler imaging of 12 biopsy markers was performed and consensus scoring of the degree of twinkling (0 [no twinkling] to 4 [exuberant twinkling]) was obtained for each of the markers. The surface roughness characteristics of the markers were measured using 3-D coherence scanning interferometry. The 3 markers scoring at least 3 for twinkling in vitro were cork, Q and Vision. Of these 3 markers, only the cork marker scored a 4 ex vivo and in cadaveric tissue. Surface roughness metrics demonstrated a positive estimated correlation with the twinkling scores (rho = 0.33, 95% CI = [-0.48 to 0.84]). Of the 12 markers tested, the markers that twinkled corresponded to surface roughness measured with non-contact 3-D optical imaging. Qualitatively, lower color scales and color frequencies optimized twinkling, but the most specific qualitative predictor of confidence in twinkling was insensitivity to changes in color scale and color frequency values.


Asunto(s)
Artefactos , Ultrasonografía Doppler en Color , Axila , Biopsia , Humanos , Ultrasonografía
10.
Brain Sci ; 11(4)2021 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-33921861

RESUMEN

Computational fluid dynamics (CFD) has grown as a tool to help understand the hemodynamic properties related to the rupture of cerebral aneurysms. Few of these studies deal specifically with aneurysm growth and most only use a single time instance within the aneurysm growth history. The present retrospective study investigated four patient-specific aneurysms, once at initial diagnosis and then at follow-up, to analyze hemodynamic and morphological changes. Aneurysm geometries were segmented via the medical image processing software Mimics. The geometries were meshed and a computational fluid dynamics (CFD) analysis was performed using ANSYS. Results showed that major geometry bulk growth occurred in areas of low wall shear stress (WSS). Wall shape remodeling near neck impingement regions occurred in areas with large gradients of WSS and oscillatory shear index. This study found that growth occurred in areas where low WSS was accompanied by high velocity gradients between the aneurysm wall and large swirling flow structures. A new finding was that all cases showed an increase in kinetic energy from the first time point to the second, and this change in kinetic energy seems correlated to the change in aneurysm volume.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA