1.
Med Dosim ; 40(1): 37-43, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25263491

RESUMEN

In proton therapy, passive scattered proton plans use compensators to conform the dose to the distal surface of the planning volume. These devices are custom made from acrylic or wax for each treatment field using either a plunge-drilled or smooth-milled compensator design. The purpose of this study was to investigate if there is a clinical benefit of generating passive scattered proton radiation treatment plans with the smooth compensator design. We generated 4 plans with different techniques using the smooth compensators. We chose 5 sites and 5 patients for each site for the range of dosimetric effects to show adequate sample. The plans were compared and evaluated using multicriteria (MCA) plan quality metrics for plan assessment and comparison using the Quality Reports [EMR] technology by Canis Lupus LLC. The average absolute difference for dosimetric metrics from the plunged-depth plan ranged from -4.7 to +3.0 and the average absolute performance results ranged from -6.6% to +3%. The manually edited smooth compensator plan yielded the best dosimetric metric, +3.0, and performance, + 3.0% compared to the plunged-depth plan. It was also superior to the other smooth compensator plans. Our results indicate that there are multiple approaches to achieve plans with smooth compensators similar to the plunged-depth plans. The smooth compensators with manual compensator edits yielded equal or better target coverage and normal tissue (NT) doses compared with the other smooth compensator techniques. Further studies are under investigation to evaluate the robustness of the smooth compensator design.


Asunto(s)
Neoplasias/radioterapia , Terapia de Protones , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Alta Energía/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Radioterapia de Alta Energía/métodos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Dispersión de Radiación , Sensibilidad y Especificidad , Resultado del Tratamiento
2.
Pract Radiat Oncol ; 2(4): 296-305, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-24674168

RESUMEN

PURPOSE: This study quantifies variation in radiation treatment plan quality for plans generated by a population of treatment planners given very specific plan objectives. METHODS AND MATERIALS: A "Plan Quality Metric" (PQM) with 14 submetrics, each with a unique value function, was defined for a prostate treatment plan, serving as specific goals of a hypothetical "virtual physician." The exact PQM logic was distributed to a population of treatment planners (to remove ambiguity of plan goals or plan assessment methodology) as was a predefined computed tomographic image set and anatomic structure set (to remove anatomy delineation as a variable). Treatment planners used their clinical treatment planning system (TPS) to generate their best plan based on the specified goals and submitted their results for analysis. RESULTS: One hundred forty datasets were received and 125 plans accepted and analyzed. There was wide variability in treatment plan quality (defined as the ability of the planners and plans to meet the specified goals) quantified by the PQM. Despite the variability, the resulting PQM distributions showed no statistically significant difference between TPS employed, modality (intensity modulated radiation therapy versus arc), or education and certification status of the planner. The PQM results showed negligible correlation to number of beam angles, total monitor units, years of experience of the planner, or planner confidence. CONCLUSIONS: The ability of the treatment planners to meet the specified plan objectives (as quantified by the PQM) exhibited no statistical dependence on technologic parameters (TPS, modality, plan complexity), nor was the plan quality statistically different based on planner demographics (years of experience, confidence, certification, and education). Therefore, the wide variation in plan quality could be attributed to a general "planner skill" category that would lend itself to processes of continual improvement where best practices could be derived and disseminated to improve the mean quality and minimize the variation in any population of treatment planners.