Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Sensors (Basel) ; 22(19)2022 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-36236709

RESUMEN

Microwave ablation is commonly used in soft tissue tumors, but its application in bone tumors has been barely analyzed. Antennas to treat bone tissue (~3 cm2), has been lately designed. Bone tumors at pathological stage T1 can reach 8 cm wide. An antenna cannot cover it; therefore, our goal is to evaluate the thermal performance of multi-antenna arrays. Linear, triangular, and square configurations of double slot (DS) and monopole (MTM) antennas were evaluated. A parametric study (finite element method), with variations in distance between antennas (ad) and bone thickness (bt) was implemented. Array feasibility was evaluated by SWR, ablated tissue volume, etc. The linear configuration with DS and MTM antennas showed SWR ≤ 1.6 for ad = 1 mm−15 mm and bt = 20 mm−40 mm, and ad = 10 mm−15 mm and bt = 25 mm−40 mm, respectively; the triangular showed SWR ≤ 1.5 for ad = 5 mm−15 mm and bt = 20 mm−40 mm and ad = 10 mm−15 mm and bt = 25 mm−40 mm. The square configuration (DS) generated SWR ≤ 1.5 for ad = 5 mm−20 mm and bt = 20 mm−40 mm, and the MTM, SWR ≤ 1.5 with ad = 10 mm and bt = 25 mm−40 mm. Ablated tissue was 4.65 cm3−10.46 cm3 after 5 min. According to treatment time and array configuration, maximum temperature and ablated tissue is modified. Bone tumors >3 cm3 can be treated by these antenna-arrays.


Asunto(s)
Neoplasias Óseas , Microondas , Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/terapia , Huesos , Análisis de Elementos Finitos , Humanos , Microondas/uso terapéutico , Temperatura
2.
Sensors (Basel) ; 21(11)2021 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-34204151

RESUMEN

Medical infrared thermography has proven to be a complementary procedure to physiological disorders, such as the diabetic foot. However, the technique remains essentially based on 2D images that display partial anatomy. In this context, a 3D thermal model provides improved visualization and faster inspection. This paper presents a 3D reconstruction method associated with temperature information. The proposed solution is based on a Structure from Motion and Multi-view Stereo approach, exploiting a set of multimodal merged images. The infrared images were obtained by automatically processing the radiometric data to remove thermal interferences, segment the RoI, enhance false-color contrast, and for multimodal co-registration under a controlled environment and a ∆T < 2.6% between the RoI and thermal interferences. The geometric verification accuracy was 77% ± 2%. Moreover, a normalized error was adjusted per sample based on a linear model to compensate for the curvature emissivity (error ≈ 10% near to 90°). The 3D models were displayed with temperature information and interaction controls to observe any point of view. The temperature sidebar values were assigned with information retrieved only from the RoI. The results have proven the feasibility of the 3D multimodal construction to be used as a promising tool in the diagnosis of diabetic foot.


Asunto(s)
Diabetes Mellitus , Pie Diabético , Humanos , Imagenología Tridimensional , Modelos Anatómicos , Movimiento (Física) , Radiometría , Termografía
3.
Int J Hyperthermia ; 32(2): 121-31, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26708742

RESUMEN

PURPOSE: The aim of this study was to design an applicator for haemostasis usage needing lower acoustic intensities (<880 W/cm(2)) than in previous devices intended for it, which is based on ultrasound propagation FEM modelling using a 2-MHz HIFU transducer. MATERIALS AND METHODS: Acoustic field characterisation and numerical simulations in water were performed with and without the proposed applicator. Parameters such as form factor, ellipsoidal shape ratio, and Euclidean distance were used (among others) to compare simulated data with transducer measurements without applicator. A low density polyethylene cone was manufactured from geometries validated from acoustic field modelling. The hollow cone was filled with 10% polyacrylamide gel as a coupling medium with liver phantom or chicken liver. Focal temperature was measured with a thermocouple embedded in the phantom for 1-20 W driving powers for 120 s. Standing wave ratios (SWR) were used as coupling indexes. Ex vivo experimentation in chicken liver was made at 10-20 W. RESULTS: Simulated acoustic patterns showed good concordance with measurements. Experimental focal distance was 20.72 ± 0.24 mm, while the simulated was 19.79 mm (≈4% error). SWR at low power were: 2.01 with transducer emitting in air, 1.53 at applicator tip, and 1.35 after phantom placement. Average SWR at high power was 1.31. Similarity of percentages for data comparison in focal plane was over 60%. Maximum temperature measured at focus was 88.7 °C with 20 W after 85 s. CONCLUSIONS: Temperatures reached at focus suggest that this applicator has good efficiency, which notably reduces the power typically needed for haemostasis effect.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación/instrumentación , Acústica , Animales , Pollos , Diseño de Equipo , Análisis de Elementos Finitos , Hemostasis , Hígado , Modelos Teóricos , Polietileno , Transductores
4.
Front Neurosci ; 15: 702781, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35126033

RESUMEN

Non-invasive Functional Electrical Stimulation (FES) is a technique applied for motor rehabilitation of patients with central nervous system injury. This technique requires programmable multichannel systems to configure the stimulation parameters (amplitude, frequency, and pulse width). Most FES systems are based on microcontrollers with fixed architecture; this limits the control of the parameters and the scaling to multiple channels. Although field programmable gate arrays (FPGA) have been used in FES systems as alternative to microcontrollers, most of them focus on signal acquisition, processing, or communication functions, or are for invasive stimulation. A few FES systems report using FPGAs for parameter configuration and pulse generation in non-invasive FES. However, generally they limit the value of the frequency or amplitude parameters to enable multichannel operation. This restricts free selection of parameters and implementation of modulation patterns, previously reported to delay FES-induced muscle fatigue. To overcome those limitations, this paper presents a proof-of-concept (technology readiness level three-TRL 3) regarding the technical feasibility and potential use of an FPGA-based pulse generator for non-invasive FES applications (PG-nFES). The main aims were: (1) the development of a flexible pulse generator for FES applications and (2) to perform a proof-of-concept of the system, comprising: electrical characterization of the stimulation parameters, and verification of its potential for upper limb FES applications. Biphasic stimulation pulses with high linearity (r 2 > 0.9998) and repeatability (>0.81) were achieved by combining the PG-nFES with a current-controlled output stage. Average percentage error in the characterizations was under 3% for amplitude (1-48 mA) and pulse width (20-400 µs), and 0% for frequency (10-150 Hz). A six-channel version of the PG-nFES was implemented to demonstrate the scalability feature. The independence of parameters was tested with three patterns of co-modulation of two parameters. Moreover, two complete FES channels were implemented and the claimed features of the PG-nFES were verified by performing upper limb functional movements involving the hand and the arm. Finally, the system enabled implementation of a stimulation pattern with co-modulation of frequency and pulse width, applied successfully for efficient elbow during repetitions of a functional movement.

5.
Technol Cancer Res Treat ; 17: 1533033818794939, 2018 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-30157721

RESUMEN

Breast cancer represents a rising problem concerning public health worldwide. Current efforts are aimed to the development of new minimally invasive and conservative treatment procedures for this disease. A treatment approach for invasive breast ductal carcinoma could be based on electroporation. Hence, in order to determine the effectiveness of electrochemotherapy in the treatment of this disease, 12 electrode models were investigated on realistic patient-specific computational breast models of 3 patients diagnosed by Digital Breast Tomosynthesis imaging. The electrode models exhibit 4, 5, and 6 needles arranged in 4 geometric configurations (delta, diamond, and star) and 3 different needle spacing resulting in a total of 12 needle-electrode arrays. Electric field distribution in the tumors and a surrounding safety margin of 1 cm around the tumor edge is computed using the finite element method. Efficiency of the electrode arrays was determined hierarchically based on (1) percentage of tumor volume reversibly electroporated, (2) percentage of tumor volume irreversibly electroporated, (3) percentage of treated safety margin volume, (4) minimal invasiveness, that is, minimal number of electrodes used, (5) minimal activated electrode pairs, and (6) minimal electric current. Results show that 3 electrode arrays (4 needle-delta, 5 needle-diamond, and 6 needle-star) with fixed-geometry configuration could be used in the treatment with electrochemotherapy of invasive breast ductal carcinomas ranging from 1 to 5 cm3 along with a surrounding safety margin of 1 cm.


Asunto(s)
Neoplasias de la Mama/tratamiento farmacológico , Carcinoma Ductal/tratamiento farmacológico , Electroquimioterapia , Anciano , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Carcinoma Ductal/diagnóstico por imagen , Carcinoma Ductal/patología , Electrodos , Femenino , Análisis de Elementos Finitos , Humanos , Persona de Mediana Edad , Modelos Biológicos , Agujas , Fantasmas de Imagen
6.
J Healthc Eng ; 2018: 2350834, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29732046

RESUMEN

Due to damage of the nervous system, patients experience impediments in their daily life: severe fatigue, tremor or impaired hand dexterity, hemiparesis, or hemiplegia. Surface electromyography (sEMG) signal analysis is used to identify motion; however, standardization of electrode placement and classification of sEMG patterns are major challenges. This paper describes a technique used to acquire sEMG signals for five hand motion patterns from six able-bodied subjects using an array of recording and stimulation electrodes placed on the forearm and its effects over functional electrical stimulation (FES) and volitional sEMG combinations, in order to eventually control a sEMG-driven FES neuroprosthesis for upper limb rehabilitation. A two-part protocol was performed. First, personalized templates to place eight sEMG bipolar channels were designed; with these data, a universal template, called forearm electrode set (FELT), was built. Second, volitional and evoked movements were recorded during FES application. 95% classification accuracy was achieved using two sessions per movement. With the FELT, it was possible to perform FES and sEMG recordings simultaneously. Also, it was possible to extract the volitional and evoked sEMG from the raw signal, which is highly important for closed-loop FES control.


Asunto(s)
Estimulación Eléctrica/métodos , Electromiografía/métodos , Mano/fisiopatología , Procesamiento de Señales Asistido por Computador , Adulto , Femenino , Hemiplejía/terapia , Humanos , Masculino , Músculo Esquelético , Adulto Joven
7.
J Healthc Eng ; 2018: 9397105, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30651950

RESUMEN

Diabetic skin manifestations, previous to ulcers and wounds, are not highly accounted as part of diagnosis even when they represent the first symptom of vascular damage and are present in up to 70% of patients with diabetes mellitus type II. Here, an application for skin macules characterization based on a three-stage segmentation and characterization algorithm used to classify vascular, petechiae, trophic changes, and trauma macules from digital photographs of the lower limbs is presented. First, in order to find the skin region, a logical multiplication is performed on two skin masks obtained from color space transformations; dynamic thresholds are stabilised to self-adjust to a variety of skin tones. Then, in order to locate the lesion region, illumination enhancement is performed using a chromatic model color space, followed by a principal component analysis gray-scale transformation. Finally, characteristics of each type of macule are considered and classified; morphologic properties (area, axes, perimeter, and solidity), intensity properties, and a set of shade indices (red, green, blue, and brown) are proposed as a measure to obviate skin color differences among subjects. The values calculated show differences between macules with a statistical significance, which agree with the physician's diagnosis. Later, macule properties are fed to an artificial neural network classifier, which proved a 97.5% accuracy, to differentiate between them. Characterization is useful in order to track macule changes and development along time, provides meaningful information to provide early treatments, and offers support in the prevention of amputations due to diabetic feet. A graphical user interface was designed to show the properties of the macules; this application could be the background of a future Diagnosis Assistance Tool for educational (i.e., untrained physicians) and preventive assistance technology purposes.


Asunto(s)
Complicaciones de la Diabetes/diagnóstico por imagen , Diabetes Mellitus Tipo 2/complicaciones , Procesamiento de Imagen Asistido por Computador/métodos , Pierna/diagnóstico por imagen , Trastornos de la Pigmentación/diagnóstico por imagen , Piel/diagnóstico por imagen , Algoritmos , Color , Gráficos por Computador , Complicaciones de la Diabetes/patología , Diabetes Mellitus Tipo 2/diagnóstico por imagen , Pie Diabético/complicaciones , Humanos , Pierna/patología , Redes Neurales de la Computación , Fotograbar , Trastornos de la Pigmentación/patología , Análisis de Componente Principal , Púrpura/patología , Piel/patología , Anomalías Cutáneas/diagnóstico por imagen , Pigmentación de la Piel , Programas Informáticos , Interfaz Usuario-Computador
8.
Comput Math Methods Med ; 2017: 1562869, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29375651

RESUMEN

Malignant neoplasms are one of the principal world health concerns and breast cancer is the most common type of cancer in women. Advances in cancer detection technologies allow treating it in early stages; however, it is necessary to develop treatments which carry fewer complications and aesthetic repercussions. This work presents a feasibility study for the use of microwave ablation as a novel technique for breast cancer treatment. A microwave applicator design is also being proposed for this purpose. The coupling of the designed antenna was predicted with computer simulation. The standing wave ratio obtained through simulation was 1.87 and the result of experimental validation was 1.04. The optimized antenna has an optimal coupling (SWR = 1.04) so ablation temperatures can be achieved in a relatively short time using low power. Varying the time and power, the heating pattern can be changed to treat different tumors. However, as some discrepancies are still present, a deeper study of the dielectric properties and their variation with temperature is required.


Asunto(s)
Análisis de Elementos Finitos , Procesamiento de Imagen Asistido por Computador/métodos , Glándulas Mamarias Animales/diagnóstico por imagen , Algoritmos , Animales , Ablación por Catéter , Simulación por Computador , Diseño de Equipo , Femenino , Calor , Humanos , Microondas , Modelos Estadísticos , Fantasmas de Imagen , Datos Preliminares , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA