Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 227
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Neuroeng Rehabil ; 21(1): 35, 2024 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-38454427

RESUMEN

BACKGROUND: Persons with a transfemoral amputation (TFA) often experience difficulties in daily-life ambulation, including an asymmetrical and less stable gait pattern and a greater cognitive demand of walking. However, it remains unclear whether this is effected by the prosthetic suspension, as eliminating the non-rigid prosthetic connection may influence stability and cortical activity during walking. Spatiotemporal and stability-related gait parameters, as well as cortical activity during walking, were evaluated between highly active individuals (MFC-level K3-4) with a TFA and able-bodied (AB) persons, and between persons with a bone-anchored prosthesis (BAP) and those with a socket-suspended prosthesis (SSP). METHODS: 18 AB persons and 20 persons with a unilateral TFA (10 BAP-users, 10 SSP-users) walked on a treadmill at their preferred speed. Spatiotemporal and margin of stability parameters were extracted from three-dimensional movement recordings. In addition, 126-channel electroencephalogram (EEG) was recorded. Brain-related activity from several cortical areas was isolated using independent component analysis. Source-level data were divided into gait cycles and subjected to time-frequency analysis to determine gait-cycle dependent modulations of cortical activity. RESULTS: Persons with TFA walked with smaller and wider steps and with greater variability in mediolateral foot placement than AB subjects; no significant differences were found between BAP- and SSP-users. The EEG analysis yielded four cortical clusters in frontal, central (both hemispheres), and parietal areas. No statistically significant between-group differences were found in the mean power over the entire gait cycle. The event-related spectral perturbation maps revealed differences in power modulations (theta, alpha, and beta bands) between TFA and AB groups, and between BAP- and SSP-users, with largest differences observed around heel strike of either leg. CONCLUSIONS: The anticipated differences in gait parameters in persons with TFA were confirmed, however no significant effect of the fixed suspension of a BAP was found. The preliminary EEG findings may indicate more active monitoring and control of stability in persons with TFA, which appeared to be timed differently in SSP than in BAP-users. Future studies may focus on walking tasks that challenge stability to further investigate differences related to prosthetic suspension.


Asunto(s)
Amputados , Miembros Artificiales , Prótesis Anclada al Hueso , Humanos , Marcha , Amputación Quirúrgica , Caminata , Fenómenos Biomecánicos , Diseño de Prótesis
2.
Sensors (Basel) ; 24(8)2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38676056

RESUMEN

This paper introduces a method for measuring 3D tibiofemoral kinematics using a multi-channel A-mode ultrasound system under dynamic conditions. The proposed system consists of a multi-channel A-mode ultrasound system integrated with a conventional motion capture system (i.e., optical tracking system). This approach allows for the non-invasive and non-radiative quantification of the tibiofemoral joint's six degrees of freedom (DOF). We demonstrated the feasibility and accuracy of this method in the cadaveric experiment. The knee joint's motions were mimicked by manually manipulating the leg through multiple motion cycles from flexion to extension. To measure it, six custom ultrasound holders, equipped with a total of 30 A-mode ultrasound transducers and 18 optical markers, were mounted on various anatomical regions of the lower extremity of the specimen. During experiments, 3D-tracked intra-cortical bone pins were inserted into the femur and tibia to measure the ground truth of tibiofemoral kinematics. The results were compared with the tibiofemoral kinematics derived from the proposed ultrasound system. The results showed an average rotational error of 1.51 ± 1.13° and a translational error of 3.14 ± 1.72 mm for the ultrasound-derived kinematics, compared to the ground truth. In conclusion, this multi-channel A-mode ultrasound system demonstrated a great potential of effectively measuring tibiofemoral kinematics during dynamic motions. Its improved accuracy, nature of non-invasiveness, and lack of radiation exposure make this method a promising alternative to incorporate into gait analysis and prosthetic kinematic measurements later.


Asunto(s)
Imagenología Tridimensional , Articulación de la Rodilla , Ultrasonografía , Humanos , Fenómenos Biomecánicos , Articulación de la Rodilla/fisiología , Articulación de la Rodilla/diagnóstico por imagen , Ultrasonografía/métodos , Imagenología Tridimensional/métodos , Tibia/diagnóstico por imagen , Tibia/fisiología , Rango del Movimiento Articular/fisiología , Fémur/fisiología , Fémur/diagnóstico por imagen , Rodilla/fisiología , Rodilla/diagnóstico por imagen
3.
Clin Orthop Relat Res ; 481(7): 1373-1384, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-36607733

RESUMEN

BACKGROUND: The most frequently occurring adverse events in individuals with a transfemoral amputation treated with a bone-anchored prosthesis are soft tissue infections and stoma-related complications. These soft tissue complications are believed to be influenced by surgical technique and implant design, but little is known about the effect of changes to treatment on these events. QUESTIONS/PURPOSES: (1) What is the result of surgical technique and implant modifications on the incidence of soft tissue infections and stoma-related complications in transfemoral bone-anchored prosthesis users, depending on whether they had a conventional stoma and a cobalt-chrome-molybdenum (CoCrMo) osseointegration implant (treatment period 2009 to 2013) or a shallower stoma and titanium osseointegration implant (2015 to 2018)? (2) What is the incidence of serious complications, such as bone or implant infection, aseptic loosening, intramedullary stem breakage, and periprosthetic fracture? METHODS: Between 2009 and 2013, we performed osseointegration implant surgery using a conventional surgical technique and a CoCrMo implant in 42 individuals who had a lower extremity amputation experiencing socket-related problems that resulted in limited prosthesis use. We considered all individuals treated with two-stage surgery with a standard press-fit transfemoral osseointegration implant as potentially eligible for inclusion. Based on this, 100% (42) were eligible, and 5% (two of 42) were excluded because they did not provide informed consent, leaving 95% (40 of 42) for analysis. Between 2015 and 2018, we treated 79 individuals with similar indications with osseointegration implant surgery, now also treating individuals with dysvascular amputations. We used an adapted surgical technique resulting in a shallower stoma combined with a titanium implant. Using the same eligibility criteria as for the first group, 51% (40 of 79) were eligible; 49% (39 of 79) were excluded because they were treated with transtibial amputation, a patient-specific implant, or single-stage surgery and 1% (one of 79) were lost before the 2-year follow-up interval, leaving 49% (39 of 79) for analysis. The period of 2013 to 2015 was a transitional period and was excluded from analysis in this study to keep groups reasonably comparable and to compare a historical approach with the present approach. Hence, we presented a comparative study of two study groups (defined by surgical technique and implant design) with standardized 2-year follow-up. The risk factors for adverse events were similar between groups, although individuals treated with the shallow stoma surgical technique and titanium implant potentially possessed an increased risk because of the inclusion of individuals with dysvascular amputation and the discontinuation of prolonged postoperative antibiotic prophylaxis. Outcomes studied were soft tissue infections and stoma-related complications (hypergranulation or keloid formation as well as stoma redundant tissue) and bone or implant infection, aseptic loosening, implant stem breakage, periprosthetic fracture, and death. RESULTS: Patients treated with the shallow stoma surgical technique and titanium implant experienced fewer soft tissue infections (13 versus 76 events, absolute risk 0.17 [95% CI 0.09 to 0.30] versus 0.93 [95% CI 0.60 to 1.45]; p < 0.01), which were treated with less invasive measures, and fewer stoma redundant tissue events (0 versus five events, absolute risk 0 versus 0.06 [95% CI 0.03 to 0.14]) than patients treated with the conventional stoma surgical technique and CoCrMo implant. This was contrasted by an increased incidence of surgical site infections occurring between surgical stages 1 and 2, when no stoma was yet created, after the implementation of treatment changes (conventional surgery and CoCrMo implant versus shallow stoma surgery and titanium implant: one versus 11 events, absolute risk 0.01 [95% CI 0.00 to 0.08] versus 0.14 [95% CI 0.08 to 0.25]; p = 0.02). Patients treated with the shallow stoma surgical technique and titanium implant did not experience serious complications, although bone infections occurred (six events in 8% [three of 40] of patients) in the conventional surgery and CoCrMo implant group, all of which were successfully treated with implant retention. CONCLUSION: Adaptations to surgical technique and newer implant designs, as well as learning curve and experience, have resulted in a reduced incidence and severity of soft tissue infections and stoma redundant tissue, contrasted by an increase in surgical site infections before stoma creation. Serious complications such as deep implant infection were infrequent in this 2-year follow-up period. We believe the benefits of these treatment modifications outweigh the disadvantages and currently advise surgeons to create a shallower stoma with a stable soft tissue envelope, combined with a titanium implant. LEVEL OF EVIDENCE: Level III, therapeutic study.


Asunto(s)
Prótesis Anclada al Hueso , Fracturas Periprotésicas , Infecciones de los Tejidos Blandos , Humanos , Oseointegración , Infección de la Herida Quirúrgica , Titanio , Diseño de Prótesis , Resultado del Tratamiento
4.
J Neuroeng Rehabil ; 20(1): 1, 2023 01 12.
Artículo en Inglés | MEDLINE | ID: mdl-36635703

RESUMEN

BACKGROUND: When developing new lower limb prostheses, prototypes are tested to obtain insights into the performance. However, large variations between research protocols may complicate establishing the potential added value of newly developed prototypes over other prostheses. OBJECTIVE: This review aims at identifying participant characteristics, research protocols, reference values, aims, and corresponding outcome measures used during prosthesis prototype testing on people with a transfemoral amputation. METHODS: A systematic search was done on PubMed and Scopus from 2000 to December 2020. Articles were included if testing was done on adults with transfemoral or knee disarticulation amputation; testing involved walking with a non-commercially available prototype leg prosthesis consisting of at least a knee component; and included evaluations of the participants' functioning with the prosthesis prototype. RESULTS: From the initial search of 2027 articles, 48 articles were included in this review. 20 studies were single-subject studies and 4 studies included a cohort of 10 or more persons with a transfemoral amputation. Only 5 articles reported all the pre-defined participant characteristics that were deemed relevant. The familiarization time with the prosthesis prototype prior to testing ranged from 5 to 10 min to 3 months; in 25% of the articles did not mention the extent of the familiarization period. Mobility was most often mentioned as the development or testing aim. A total of 270 outcome measures were identified, kinetic/kinematic gait parameters were most often reported. The majority of outcome measures corresponded to the mobility aim. For 48% of the stated development aims and 4% of the testing aims, no corresponding outcome measure could be assigned. Results indicated large inconsistencies in research protocols and outcome measures used to validate pre-determined aims. CONCLUSIONS: The large variation in prosthesis prototype testing and reporting calls for the development of a core set of reported participant characteristics, testing protocols, and specific and well-founded outcome measures, tailored to the various aims and development phases. The use of such a core set can give greater insights into progress of developments and determine which developments have additional benefits over the state-of-the-art. This review may contribute as initial input towards the development of such a core set.


Asunto(s)
Amputados , Miembros Artificiales , Adulto , Humanos , Amputación Quirúrgica , Marcha , Caminata , Rodilla
5.
Sensors (Basel) ; 21(16)2021 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-34451033

RESUMEN

The performance of military tasks is often exacerbated by additional load carriage, leading to increased physical demand. Previous studies showed that load carriage may lead to increased risk of developing musculoskeletal injuries, a reduction in task speed and mobility, and overall performance degradation. However, these studies were limited to a non-ambulatory setting, and the underlying causes of performance degradation remain unclear. To obtain insights into the underlying mechanisms of reduced physical performance during load-carrying military activities, this study proposes a combination of IMUs and musculoskeletal modeling. Motion data of military subjects was captured using an Xsens suit during the performance of an agility run under three different load-carrying conditions (no load, 16 kg, and 31 kg). The physical performance of one subject was assessed by means of inertial motion-capture driven musculoskeletal analysis. Our results showed that increased load carriage led to an increase in metabolic power and energy, changes in muscle parameters, a significant increase in completion time and heart rate, and changes in kinematic parameters. Despite the exploratory nature of this study, the proposed approach seems promising to obtain insight into the underlying mechanisms that result in performance degradation during load-carrying military activities.


Asunto(s)
Personal Militar , Sistema Musculoesquelético , Fenómenos Biomecánicos , Humanos , Rendimiento Físico Funcional , Soporte de Peso
6.
J Magn Reson Imaging ; 51(2): 446-458, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31332865

RESUMEN

BACKGROUND: Various diagnostic modalities are available to assess the problematic knee arthroplasty. Visualization of soft-tissue structures in relation to the arthroplasty and bone remains difficult. Recent developments in MRI sequences could make MRI a viable addition to the diagnostic arsenal. PURPOSE: To review the diagnostic properties of MRI, to identify certain causes of complaints that may be directly related to implant failure of total (TKA) or unicompartmental knee arthroplasty (UKA); infection, loosening and wear, instability, malalignment, arthrofibrosis, or patellofemoral problems. STUDY TYPE: Systematic review. POPULATION: Twenty-three studies were included: 16 TKA, four UKA, and three cadaveric studies. Causes of knee arthroplasty complaints analyzed were; infection (three), loosening and wear (11), malalignment (five) and instability (four). FIELD STRENGTH AND SEQUENCES: No field strength or sequence restrictions. ASSESSMENT: PubMed, SCOPUS, and EMBASE were searched. Risk of bias was assessed using the COnsensus-based Standards for the selection of health Measurement Instruments (COSMIN) and the QUality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). STATISTICAL TESTS: The results of the original research articles are stated. RESULTS: Fifteen studies assessed the reproducibility of analyzing infection, loosening and wear, and malalignment. Fourteen of 15 studies were deemed as adequate to good quality. Results showed a moderate to excellent agreement (ICC/K 0.55-0.97). Fourteen studies addressed the accuracy. For infection and loosening and wear the sensitivity and specificity estimates varied between 0.85-0.97 and 0.70-1.00, respectively. The accuracy for malalignment was excellent (r ≥ 0.81). For these studies QUADAS-2 analysis suggested few risks of bias. A meta-analysis was not possible due to the heterogeneity of the data. DATA CONCLUSION: This study supports that MRI can be used with overall reproducible and accurate results for diagnosing infection, loosening and wear, and malalignment after knee arthroplasty. Nonetheless, studies regarding the diagnosis of instability, arthrofibrosis or patellofemoral complaints using MRI are limited and inconclusive. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:446-458.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
BMC Musculoskelet Disord ; 21(1): 395, 2020 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-32571362

RESUMEN

BACKGROUND: An alternative to the current gold standard in operative treatment of displaced midshaft clavicle fractures (DMCF) using plate osteosynthesis, is internal fixation by means of intramedullary fixation devices. These devices differ considerably in their specifications and characteristics and an evaluation of their clinical results is warranted. The aim of this systematic review is to generate an overview of functional outcomes and complications in the management of DMCF per available intramedullary device. METHODS: A systematic review was conducted to identify all papers reporting functional outcomes, union rates and/or complications using an intramedullary fixation device for the management of midshaft clavicle fractures. Multiple databases and trial registries were searched from inception until February 2020. Meta-analysis was conducted based on functional outcomes and type of complication per type of intramedullary fixation device. Pooled estimates of functional outcomes scores and incidence of complications were calculated using a random effects model. Risk of bias and quality was assessed using the Cochrane risk of bias and ROBINS-I tools. The confidence in estimates were rated and described according to the recommendations of the GRADE working group. RESULTS: Sixty-seven studies were included in this systematic review. The majority of studies report on the use of Titanium Elastic Nails (TEN). At 12 months follow up the Titanium Elastic Nail and Sonoma CRx report an average Constant-Murley score of 94.4 (95%CI 93-95) and 94.0 (95%CI 92-95) respectively (GRADE High). The most common reported complications after intramedullary fixation are implant-related and implant-specific. For the TEN, hardware irritation and protrusion, telescoping or migration, with a reported pooled incidence 20% (95%CI 14-26) and 12% (95%CI 8-18), are most common (GRADE Moderate). For the Rockwood/Hagie Pin, hardware irritation is identified as the most common complication with 22% (95%CI 13-35) (GRADE Low). The most common complication for the Sonoma CRx was cosmetic dissatisfaction in 6% (95%CI 2-17) of cases (GRADE Very low). CONCLUSION: Although most studies were of low quality, good functional results and union rates irrespective of the type of device are found. However, there are clear device-related and device-specific complications for each. The results of this systematic review and meta-analysis can help guide surgeons in choosing the appropriate operative strategy, implant and informing their patient. LEVEL OF EVIDENCE: IV.


Asunto(s)
Placas Óseas , Clavícula/lesiones , Fijación Intramedular de Fracturas/efectos adversos , Fracturas Óseas/cirugía , Clavícula/cirugía , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Humanos , Complicaciones Posoperatorias , Ensayos Clínicos Controlados Aleatorios como Asunto , Recurrencia , Reoperación
8.
Magn Reson Med ; 80(5): 1799-1811, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-29508449

RESUMEN

PURPOSE: 3D time-resolved (4D) phase contrast MRI can be used to study muscle contraction. However, 3D coverage with sufficient spatiotemporal resolution can only be achieved by interleaved acquisitions during many repetitions of the motion task, resulting in long scan times. The aim of this study was to develop a compressed sensing accelerated 4D phase contrast MRI technique for quantification of velocities and strain rate of the muscles in the lower leg during active plantarflexion/dorsiflexion. METHODS: Nine healthy volunteers were scanned during active dorsiflexion/plantarflexion task. For each volunteer, we acquired a reference scan, as well as 4 different accelerated scans (k-space undersampling factors: 3.14X, 4.09X, 4.89X, and 6.41X) obtained using Cartesian Poisson disk undersampling schemes. The data was reconstructed using a compressed sensing pipeline. For each scan, velocity and strain rate values were quantified in the gastrocnemius lateralis, gastrocnemius medialis, tibialis anterior, and soleus. RESULTS: No significant differences in velocity values were observed as a function acceleration factor in the investigated muscles. The strain rate calculation resulted in one positive (s+ ) and one negative (s- ) eigenvalue, whereas the third eigenvalue (s3 ) was consistently 0 for all the acquisitions. No significant differences were observed for the strain rate eigenvalues as a function of acceleration factor. CONCLUSIONS: Data undersampling combined with compressed sensing reconstruction allowed obtainment of time-resolved phase contrast acquisitions with 3D coverage and quantitative information comparable to the reference scan. The 3D sensitivity of the method can help in understanding the connection between muscle architecture and muscle function in future studies.


Asunto(s)
Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Contracción Muscular/fisiología , Músculo Esquelético/diagnóstico por imagen , Algoritmos , Femenino , Humanos , Pierna/diagnóstico por imagen , Masculino
9.
Adv Exp Med Biol ; 1093: 131-142, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30306478

RESUMEN

Tracking joint motion of the lower extremity is important for human motion analysis. In this study, we present a novel ultrasound-based motion tracking system for measuring three-dimensional (3D) position and orientation of the femur and tibia in 3D space and quantifying tibiofemoral kinematics under dynamic conditions. As ultrasound is capable of detecting underlying bone surface noninvasively through multiple layers of soft tissues, an integration of multiple A-mode ultrasound transducers with a conventional motion tracking system provides a new approach to track the motion of bone segments during dynamic conditions. To demonstrate the technical and clinical feasibilities of this concept, an in vivo experiment was conducted. For this purpose the kinematics of healthy individuals were determined in treadmill walking conditions and stair descending tasks. The results clearly demonstrated the potential of tracking skeletal motion of the lower extremity and measuring six-degrees-of-freedom (6-DOF) tibiofemoral kinematics and related kinematic alterations caused by a variety of gait parameters. It was concluded that this prototyping system has great potential to measure human kinematics in an ambulant, non-radiative, and noninvasive manner.


Asunto(s)
Fémur/diagnóstico por imagen , Marcha , Imagenología Tridimensional/métodos , Ultrasonografía , Fenómenos Biomecánicos , Humanos , Extremidad Inferior , Rango del Movimiento Articular
10.
Knee Surg Sports Traumatol Arthrosc ; 26(9): 2841-2857, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29210022

RESUMEN

PURPOSE: Trochleoplasty aims to restore patellar stability. Various techniques have been described and almost all authors report successful results. However, the procedure has a significant risk of complications. Purpose of this study was to perform a systematic review and meta-analysis of the available literature to assess the rate of complications after the various techniques used for trochleoplasty procedures. MATERIALS AND METHODS: MEDLINE, EMBASE, Web of Science and Cochrane Library databases were searched. Studies on patients with recurrent patellar instability treated with a trochleoplasty with or without additional procedure, and reported complications were included. The primary outcome was the rate of complications per technique. A meta-analysis was performed whenever three or more studies per surgical technique could be included. RESULTS: The selection process resulted in 20 studies included for analysis. A lateral facet elevating trochlear osteotomy was reported by two studies, ten studies reported on a Bereiter trochleoplasty, five on a Dejour trochleoplasty, one on an arthroscopic technique, one on a 'modified' technique and one on a recession wedge trochleoplasty. Meta-analysis showed that proportion of recurrent dislocation was 0.04 (95% CI 0.02-0.07) for Bereiter trochleoplasty and 0.02 (95% CI 0-0.08) for Dejour trochleoplasty. These proportions were 0.06 (95% CI 0.02-0.13) and 0.09 (95% CI 0.03-0.27) for recurrent instability, 0.07 (95% CI 0.02-0.19) and 0.12 (95% CI 0.00-0.91) for patellofemoral osteoarthritis and 0.08 (95% CI 0.04-0.14) and 0.20 (95% CI 0.11-0.32) for further surgery respectively. CONCLUSION: This study demonstrates that the complications after a Bereiter and Dejour trochleoplasty including additional procedures are in the range of those of other patellar stabilizing procedures. For four other techniques, no meta-analysis could be performed. The clinical relevance of this study is that it provides clinicians with the best currently available evidence on the rate of complications after trochleoplasty procedures. This can be helpful in the process of deciding whether or not to perform such a procedure, and can be used to better inform patients about the advantages and disadvantages of different trochleoplasty procedures. LEVEL OF EVIDENCE: Level IV.


Asunto(s)
Fémur/cirugía , Inestabilidad de la Articulación/cirugía , Rótula/cirugía , Luxación de la Rótula/cirugía , Humanos , Osteoartritis de la Rodilla/complicaciones , Osteotomía/métodos
11.
Knee Surg Sports Traumatol Arthrosc ; 26(11): 3377-3385, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29560510

RESUMEN

PURPOSE: When downsizing the femoral component to prevent mediolateral overhang, notching of the anterior femoral cortex may occur, which could be solved by flexing the femoral component. In this study, we investigated the effect of flexion of the femoral component on patellar tendon moment arm, patellofemoral forces and kinematics in posterior-referencing CR-TKA. Our hypothesis was that flexion of the femoral component increases the patellar tendon moment arm, reduces the patellofemoral forces and provides stable kinematics. METHODS: A validated musculoskeletal model of CR-TKA was used. The flexion of the femoral component was increased in four steps (0°, 3°, 6°, 9°) using posterior referencing, and different alignments were analysed in combination with three implant sizes (3, 4, 5). A chair-rising trial was analysed using the model, while simultaneously estimating quadriceps muscle force, patellofemoral contact force, tibiofemoral and patellofemoral kinematics. RESULTS: Compared to the reference case (size 4 and 0° flexion), for every 3° of increase in flexion of the femoral component the patellar tendon moment arm increased by 1% at knee extension. The peak quadriceps muscle force and patellofemoral contact force decreased by 2%, the patella shifted 0.8 mm more anteriorly and the remaining kinematics remained stable, with knee flexion. With the smaller size, the patellar tendon moment arm decreased by 6%, the quadriceps muscle force and patellofemoral contact force increased by 8 and 12%, and the patellar shifted 5 mm more posteriorly. Opposite trends were found with the bigger size. CONCLUSION: Flexing the femoral component with posterior referencing reduced the patellofemoral contact forces during a simulated chair-rising trial with a patient-specific musculoskeletal model of CR-TKA. There seems to be little risk when flexing and downsizing the femoral component, compared to when using a bigger size and neutral alignment. These findings provide relevant information to surgeons who wish to prevent anterior notching when downsizing the femoral component.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Simulación por Computador , Prótesis de la Rodilla , Articulación Patelofemoral/fisiología , Diseño de Prótesis , Fenómenos Biomecánicos , Humanos , Ligamentos Articulares/fisiología , Ligamento Rotuliano/fisiología , Músculo Cuádriceps/fisiología , Rango del Movimiento Articular/fisiología
12.
Knee Surg Sports Traumatol Arthrosc ; 26(5): 1540-1548, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-28500391

RESUMEN

PURPOSE: In total knee arthroplasty (TKA), the posterior tibial slope is not always reconstructed correctly, and the knee ligaments may become too tight in flexion. To release a tight flexion gap, surgeons can increase the posterior tibial slope using two surgical resection techniques: the anterior tibial cortex (ACR) or the centre of tibial plateau (CPR) referencing. It is not known how this choice affects the knee laxity and function during activities of daily living. The aim of this study was to investigate the effect of tibial slope on knee laxity, kinematics and forces during a squatting activity using computer simulation techniques. We hypothesised that the effects depend on the referencing technique utilised. METHODS: A validated musculoskeletal model of TKA was used. Knee laxity tests were simulated in flexion and extension. Then, a squat motion was simulated to calculate: movement of the tibiofemoral joint (TFJ) contact points and patello-femoral joint (PFJ) contact force. All analyses were repeated with more anterior (-3°), neutral (0°), and more posterior tibial slope (+3°, +6°, +9°), and with two referencing techniques (ACR, CPR). RESULTS: Knee laxities increased dramatically with more posterior slope with the ACR technique (up to 400%), both in flexion and in extension. The CPR technique, instead, had much smaller effects (up to 42% variations). During squatting, more slope with the ACR technique resulted in larger movements of the TFJ contact point. The PFJ contact force decreased considerably with more slope with the CPR technique (12% body weight reduction every 3° more posterior slope), thanks to the preservation of the patellar height and quadriceps-femur load sharing. CONCLUSION: ACR technique alters considerably the knee laxity, both in flexion and extensions, and surgeons should be cautious about its use. More slope with CPR technique induces more favourable TFJ kinematics and loading of the knee extensor apparatus and does not substantially alter knee laxity. Preferably, the tibial slope resection should be pre-planned thoroughly and performed using CPR technique as accurately as possible. Surgeons can directly translate the results of this study into the clinical practice.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Simulación por Computador , Articulación de la Rodilla/fisiología , Tibia/anatomía & histología , Actividades Cotidianas , Anciano , Fenómenos Biomecánicos , Fémur/cirugía , Humanos , Articulación de la Rodilla/cirugía , Ligamentos Articulares/cirugía , Rótula/cirugía , Articulación Patelofemoral/cirugía , Músculo Cuádriceps/fisiología , Rango del Movimiento Articular , Tibia/cirugía
13.
J Orthop Sci ; 23(1): 105-111, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29032860

RESUMEN

BACKGROUND: The purpose of this study was to compare the mechanical stability of a relatively thin locking plate (FlexitSystem implant) with a relatively firm locking plate (TomoFix implant), both used for opening wedge high tibial osteotomy. METHODS: Seven fresh frozen paired human cadaveric tibiae were used. The opening wedge high tibial osteotomies in the left tibiae were fixated with the FlexitSystem implant and in the right tibiae with the TomoFix implant. The tibiae were CT-scanned to determine the bone mineral density. Axial loading was applied in a cyclic fashion for 50,000 cycles. We compared throughout the loading history the relative motions between the proximal and distal tibia using roentgen stereophotogrammetry analysis at set intervals. Also the strength of the reconstructions was compared using a displacement-controlled compressive test until failure. RESULTS: One pair (with the lowest bone mineral density) failed during the preparation of the osteotomy. The FlexitSystem implant displayed a similar stability compared to the TomoFix implant, with low translations (mean 2.16 ± 1.02 mm vs. 4.29 ± 5.66 mm) and rotations (mean 3.17 ± 2.04° vs. 4.30 ± 6.78°), which was not significant different. Although on average the FlexitSystem reconstructions were slightly stronger than the Tomofix reconstructions (mean 4867 ± 944 N vs. 4628 ± 1987 N), no significant (p = 0.71) differences between the two implants were found. CONCLUSION: From a biomechanical point of view, the FlexitSystem implant is a suitable alternative to the TomoFix implant for a high tibial open wedge osteotomy.


Asunto(s)
Placas Óseas , Fuerza Compresiva , Osteotomía/instrumentación , Tibia/cirugía , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Cadáver , Diseño de Equipo , Femenino , Humanos , Masculino , Osteotomía/métodos , Estadísticas no Paramétricas , Estrés Mecánico
14.
Acta Orthop ; 89(1): 59-65, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28931340

RESUMEN

Background and purpose - Hip resurfacing (HR) is a treatment option promoted for hip arthritis in young and active patients. However, adverse reactions to metal are a concern and the search for non-metallic bearing options proceeds. We present the first clinical study performed in patients using a newly developed hydrophilic polymer-on-polymer hip resurfacing device. Patients and methods - After performing extensive hip simulator tests, biocompatibility testing and animal tests (ISO 14242-1,3; 10993-3,4,5,10,11), approval was obtained from the IRB committee to enroll 15 patients in the first clinical study in humans using this experimental polymer-on-polymer hip resurfacing device. All surgeries were done by 2 experienced hip resurfacing surgeons. Clinical scores and standard radiographs as well as routine MRIs were obtained at regular intervals. Results - The surgical technique proved feasible with successful implantation of the new device using PMMA cement fixation on both sides without complications. Postoperative imaging revealed a well-positioned and well-fixed polymer resurfacing hip arthroplasty in all 4 initial cases. All 4 patients were free of pain and had good function for the first 2 months. However, in all 4 cases early cup loosening occurred between 8 and 11 weeks after surgery, necessitating immediate closure of the study. All 4 patients had a reoperation and were revised to a conventional THA. Retrieval analyses confirmed early cup loosening at the implant-cement interface in all 4 cases. The femoral components remained well attached to the cement. The periprosthetic tissues showed only small amounts of polymeric wear debris and there was only a very mild inflammatory reaction to this. Interpretation - Early cup loosening mandated a premature arrest of this study. After additional laboratory testing this failure mode was found to be the result of a small, yet measurable contraction in the cup size after exposing these implants to biological fluid divalent ion fluctuations in vivo. Currently used preclinical tests had failed to detect this failure mechanism. Modification of the polymer is essential to overcome these problems and before the potential of a polymer-on-polymer resurfacing arthroplasty may be further evaluated in patients.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Falla de Prótesis/efectos adversos , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Imagen por Resonancia Magnética , Osteoartritis de la Cadera/diagnóstico por imagen , Osteoartritis de la Cadera/cirugía , Polímeros/uso terapéutico , Radiografía
15.
Magn Reson Med ; 78(1): 58-68, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-27417271

RESUMEN

PURPOSE: To introduce a method for obtaining fat-suppressed images in real-time MRI of moving joints at 3 Tesla (T) using a bSSFP sequence with phase detection to enhance visualization of soft tissue structures during motion. METHODS: The wrist and knee of nine volunteers were imaged with a real-time bSSFP sequence while performing dynamic tasks. For appropriate choice of sequence timing parameters, water and fat pixels showed an out-of-phase behavior, which was exploited to reconstruct water and fat images. Additionally, a 2-point Dixon sequence was used for dynamic imaging of the joints, and resulting water and fat images were compared with our proposed method. RESULTS: The joints could be visualized with good water-fat separation and signal-to-noise ratio (SNR), while maintaining a relatively high temporal resolution (5 fps in knee imaging and 10 fps in wrist imaging). The proposed method produced images of moving joints with higher SNR and higher image quality when compared with the Dixon method. CONCLUSIONS: Water-fat separation is feasible in real-time MRI of moving knee and wrist at 3 T. PS-bSSFP offers movies with higher SNR and higher diagnostic quality when compared with Dixon scans. Magn Reson Med 78:58-68, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Agua Corporal/diagnóstico por imagen , Articulaciones/diagnóstico por imagen , Articulaciones/fisiología , Imagen por Resonancia Magnética/métodos , Rango del Movimiento Articular/fisiología , Procesamiento de Señales Asistido por Computador , Sistemas de Computación , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción , Adulto Joven
16.
NMR Biomed ; 30(11)2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28873255

RESUMEN

Anatomical (static) magnetic resonance imaging (MRI) is the most useful imaging technique for the evaluation and assessment of internal derangement of the knee, but does not provide dynamic information and does not allow the study of the interaction of the different tissues during motion. As knee pain is often only experienced during dynamic tasks, the ability to obtain four-dimensional (4D) images of the knee during motion could improve the diagnosis and provide a deeper understanding of the knee joint. In this work, we present a novel approach for dynamic, high-resolution, 4D imaging of the freely moving knee without the need for external triggering. The dominant knee of five healthy volunteers was scanned during a flexion/extension task. To evaluate the effects of non-uniform motion and poor coordination skills on the quality of the reconstructed images, we performed a comparison between fully free movement and movement instructed by a visual cue. The trigger signal for self-gating was extracted using principal component analysis (PCA), and the images were reconstructed using a parallel imaging and compressed sensing reconstruction pipeline. The reconstructed 4D movies were scored for image quality and used to derive bone kinematics through image registration. Using our method, we were able to obtain 4D high-resolution movies of the knee without the need for external triggering hardware. The movies obtained with and without instruction did not differ significantly in terms of image scoring and quantitative values for tibiofemoral kinematics. Our method showed to be robust for the extraction of the self-gating signal even for uninstructed motion. This can make the technique suitable for patients who, as a result of pain, may find it difficult to comply exactly with instructions. Furthermore, bone kinematics can be derived from accelerated MRI without the need for additional hardware for triggering.


Asunto(s)
Fémur/fisiología , Imagen por Resonancia Magnética/métodos , Tibia/fisiología , Adulto , Fenómenos Biomecánicos , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Articulación de la Rodilla/fisiología
17.
J Biomech Eng ; 139(8)2017 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-28462424

RESUMEN

Knowing the forces in the human body is of great clinical interest and musculoskeletal (MS) models are the most commonly used tool to estimate them in vivo. Unfortunately, the process of computing muscle, joint contact, and ligament forces simultaneously is computationally highly demanding. The goal of this study was to develop a fast surrogate model of the tibiofemoral (TF) contact in a total knee replacement (TKR) model and apply it to force-dependent kinematic (FDK) simulations of activities of daily living (ADLs). Multiple domains were populated with sample points from the reference TKR contact model, based on reference simulations and design-of-experiments. Artificial neural networks (ANN) learned the relationship between TF pose and loads from the medial and lateral sides of the TKR implant. Normal and right-turn gait, rising-from-a-chair, and a squat were simulated using both surrogate and reference contact models. Compared to the reference contact model, the surrogate contact model predicted TF forces with a root-mean-square error (RMSE) lower than 10 N and TF moments lower than 0.3 N·m over all simulated activities. Secondary knee kinematics were predicted with RMSE lower than 0.2 mm and 0.2 deg. Simulations that used the surrogate contact model ran on average three times faster than those using the reference model, allowing the simulation of a full gait cycle in 4.5 min. This modeling approach proved fast and accurate enough to perform extensive parametric analyses, such as simulating subject-specific variations and surgical-related factors in TKR.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Fenómenos Mecánicos , Modelos Biológicos , Actividades Cotidianas , Fenómenos Biomecánicos , Humanos
18.
BMC Musculoskelet Disord ; 18(1): 324, 2017 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-28764691

RESUMEN

BACKGROUND: We compared the functional outcome between conventional and high-flexion total knee arthroplasty (TKA) using kneeling and sit-to-stand tests at 1 year post-operative. In addition, the patient's daily functioning, pain and satisfaction were quantified using questionnaires. METHODS: We randomly assigned 56 patients to receive either a conventional or a high-flexion TKA. Primary outcomes were maximum flexion angle and maximum thigh-calf contact measured during kneeling at 1 year post operatively. Secondary outcomes were the angular knee velocity and ground reaction force ratio measured during sit-to-stand performance tests, and questionnaires. RESULTS: At one year post-operative, maximum knee flexion during kneeling was higher for the high-flexion TKA group (median 128.02° (range 108-146)) compared to the conventional TKA group (119.13° (range 72-135)) (p = 0.03). Maximum thigh-calf contact force was higher for the high flexion TKA group (median 17.82 N (range 2.98-114.64)) compared to the conventional TKA group (median 9.37 N (range 0.33-46.58))(p = 0.04). The sit-to-stand tests showed a significantly higher angular knee velocity in the conventional TKA group (12.12 rad/s (95%CI 0.34-23.91); p = 0.04). There were no significant differences between groups in ground reaction force ratios and patient-reported outcome scores. CONCLUSION: Although no differences were found in patient-reported outcome scores, differences in performance-based tests were clearly apparent. Standing up from a chair at 90° of knee flexion appeared to be easier for the conventional group. The kneeling test revealed significantly higher weight-bearing knee flexion for the high-flex group. Hence, if kneeling is an important activity for a patient a high-flex design may be recommendable. TRIAL REGISTRATION: The study was retrospectively registered in ClinicalTrials.gov under identifier NCT00899041 (date of registration: May 11, 2009).


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Articulación de la Rodilla/fisiología , Prótesis de la Rodilla/estadística & datos numéricos , Anciano , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Postura , Estudios Prospectivos
19.
Knee Surg Sports Traumatol Arthrosc ; 25(8): 2321-2329, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26142164

RESUMEN

PURPOSE: Femoral tunnel positioning is an important factor in anatomical ACL reconstructions. To improve accuracy, lateral radiographic support can be used to determine the correct tunnel location, applying the quadrant method. Piefer et al. (Arthroscopy 28:872-881, 2012) combined various outcomes of eight studies applying this method to one guideline. The studies included in that guideline used various insertion margins, imaging techniques and measurement methods to determine the position of the ACL centres. The question we addressed is whether condensing data from various methods into one guideline, results in a more accurate guideline than the results of one study. METHODS: The accuracy of the Piefer's guideline was determined and compared to a guideline developed by Luites et al. (2000). For both guidelines, we quantified the mean absolute differences in positions of the actual anatomical centres of the ACL, AM and PL measured on the lateral radiographs of twelve femora with the quadrant method and the positions according to the guidelines. RESULTS: The accuracy of Piefer's guidelines was 2.4 mm (ACL), 2.7 mm (AM) and 4.6 mm (PL), resulting in positions significantly different from the actual anatomical centres. Applying Luites' guidelines for ACL and PL resulted in positions not significantly different from the actual centres. The accuracies were 1.6 mm (ACL) and 2.2 mm (PL and AM), which were significantly different from Piefer for the PL centres, and therefore more accurate. CONCLUSIONS: Condensing the outcomes of multiple studies using various insertion margins, imaging techniques and measurement methods, results in inaccurate guidelines for femoral ACL tunnel positioning at the lateral view. CLINICAL RELEVANCE: An accurate femoral tunnel positioning for anatomical ACL reconstruction is a key issue. The results of this study demonstrate that averaging of various radiographic guidelines for anatomical femoral ACL tunnel placement in daily practice, can result in inaccurate tunnel positions. LEVEL OF EVIDENCE: Diagnostic study, Level 1.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/diagnóstico por imagen , Ligamento Cruzado Anterior/cirugía , Fémur/diagnóstico por imagen , Fémur/cirugía , Reconstrucción del Ligamento Cruzado Anterior/normas , Cadáver , Humanos , Reproducibilidad de los Resultados
20.
J Trauma Nurs ; 24(4): 261-269, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28692625

RESUMEN

Current immobilization techniques of the cervical spine are associated with complications including pressure ulcers, discomfort, and elevated intracranial pressures with limited access to the thorax and airway. In this study, a newly developed craniothoracic immobilizer (Pharaoh mattress) for critical care patients with cervical injury was tested for its restriction of cervical movement, peak interface pressures, comfort, and radiolucency, and compared with headblocks strapped to a spineboard. Cervical movement was measured by roentgen stereophotogrammetric analysis in 5 fresh frozen cadavers. Peak interface and discomfort pressures were measured in 10 healthy volunteers. Radiographic absorption was calculated by measuring the total emission radiation with and without immobilizer. The Pharaoh mattress caused a mean restriction of 59% (SD: 15) flexion-extension, 77% (SD: 14) lateral bending, and 93% (SD: 3) rotation, compared with the unrestricted situation. No significant differences in restriction of cervical movement were found between headblocks strapped to a spineboard and the Pharaoh mattress. The mean peak pressures on the Pharaoh mattress were significantly lower than on the spineboard. Healthy volunteers gave significantly lower numeric discomfort scores on the Pharaoh mattress than on the spineboard. The Pharaoh mattress absorbed more x-rays than the spineboard. The Pharaoh mattress provides similar restriction of cervical movement compared with headblocks strapped to a spineboard but with lower interface pressures and increased comfort. This new mattress could be useful for immobilization of the cervical spine in critical care patients with mechanically instable spinal fractures.


Asunto(s)
Lechos , Vértebras Cervicales/lesiones , Cuidados Críticos/métodos , Inmovilización/métodos , Fracturas de la Columna Vertebral/terapia , Ingeniería Biomédica/métodos , Enfermedad Crítica , Femenino , Humanos , Puntaje de Gravedad del Traumatismo , Masculino , Traumatismos del Cuello/diagnóstico , Traumatismos del Cuello/terapia , Países Bajos , Rango del Movimiento Articular/fisiología , Fracturas de la Columna Vertebral/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA