Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Occup Environ Med ; 79(8): 550-556, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35414568

RESUMEN

OBJECTIVES: To determine whether engineering controls and respiratory protection had measurable short-term impact on indium exposure and respiratory health among current indium-tin oxide production and reclamation facility workers. METHODS: We documented engineering controls implemented following our 2012 evaluation and recorded respirator use in 2012 and 2014. We measured respirable indium (Inresp) and plasma indium (InP) in 2012 and 2014, and calculated change in Inresp (∆Inresp) and InP (∆InP) by the 13 departments. We assessed symptoms, lung function, serum biomarkers of interstitial lung disease (Krebs von den Lungen (KL)-6 and surfactant protein (SP)-D) and chest high-resolution CT at both time points and evaluated workers who participated in both 2012 and 2014 for changes in health outcomes (new, worsened or improved). RESULTS: Engineering controls included installation of local exhaust ventilation in both grinding departments (Rotary and Planar) and isolation of the Reclaim department. Respiratory protection increased in most (77%) departments. ∆InP and ∆Inresp often changed in parallel by department. Among 62 workers participating in both 2012 and 2014, 18 (29%) had new or worsening chest symptoms and 2 (3%) had functional decline in lung function or radiographic progression, but average KL-6 and SP-D concentrations decreased, and no cases of clinical indium lung disease were recognised. CONCLUSIONS: Increased engineering controls and respiratory protection can lead to decreased Inresp, InP and biomarkers of interstitial lung disease among workers in 2 years. Ongoing medical monitoring of indium-exposed workers to confirm the longer-term effectiveness of preventive measures is warranted.


Asunto(s)
Enfermedades Pulmonares Intersticiales , Exposición Profesional , Biomarcadores , Estudios de Seguimiento , Humanos , Indio/efectos adversos , Enfermedades Pulmonares Intersticiales/inducido químicamente , Exposición Profesional/efectos adversos , Exposición Profesional/análisis , Proteína D Asociada a Surfactante Pulmonar , Compuestos de Estaño
2.
Occup Environ Med ; 79(2): 120-126, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34535537

RESUMEN

OBJECTIVES: Human leukocyte antigen-DP beta 1 (HLA-DPB1) with a glutamic acid at the 69th position of the ß chain (E69) genotype and inhalational beryllium exposure individually contribute to risk of chronic beryllium disease (CBD) and beryllium sensitisation (BeS) in exposed individuals. This retrospective nested case-control study assessed the contribution of genetics and exposure in the development of BeS and CBD. METHODS: Workers with BeS (n=444), CBD (n=449) and beryllium-exposed controls (n=890) were enrolled from studies conducted at nuclear weapons and primary beryllium manufacturing facilities. Lifetime-average beryllium exposure estimates were based on workers' job questionnaires and historical and industrial hygienist exposure estimates, blinded to genotype and case status. Genotyping was performed using sequence-specific primer-PCR. Logistic regression models were developed allowing for over-dispersion, adjusting for workforce, race, sex and ethnicity. RESULTS: Having no E69 alleles was associated with lower odds of both CBD and BeS; every additional E69 allele increased odds for CBD and BeS. Increasing exposure was associated with lower odds of BeS. CBD was not associated with exposure as compared to controls, yet the per cent of individuals with CBD versus BeS increased with increasing exposure. No evidence of a gene-by-exposure interaction was found for CBD or BeS. CONCLUSIONS: Risk of CBD increases with E69 allele frequency and increasing exposure, although no gene by environment interaction was found. A decreased risk of BeS with increasing exposure and lack of exposure response in CBD cases may be due to the limitations of reconstructed exposure estimates. Although reducing exposure may not prevent BeS, it may reduce CBD and the associated health effects, especially in those carrying E69 alleles.


Asunto(s)
Beriliosis/genética , Berilio/toxicidad , Cadenas beta de HLA-DP/genética , Exposición Profesional/efectos adversos , Beriliosis/epidemiología , Estudios de Casos y Controles , Enfermedad Crónica , Femenino , Genotipo , Humanos , Masculino , Polimorfismo Genético , Estudios Retrospectivos
3.
Regul Toxicol Pharmacol ; 133: 105198, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35659913

RESUMEN

Material jetting and vat photopolymerization additive manufacturing (AM) processes use liquid resins to build objects. These resins can contain skin irritants and/or sensitizers but product safety data sheets (SDSs) might not declare all ingredients. We characterized elemental and organic skin irritants and sensitizers present in 39 commercial products; evaluated the influence of resin manufacturer, system, color, and AM process type on the presence of irritants and sensitizers; and compared product SDSs to results. Among all products, analyses identified 23 irritant elements, 54 irritant organic substances, 22 sensitizing elements, and 23 sensitizing organic substances; SDSs listed 3, 9, 4, and 6 of these ingredients, respectively. Per product, the number and total mass (an indicator of potential dermal loading) of ingredients varied: five to 17 irritant elements (8.32-4756.65 mg/kg), one to 17 irritant organics (3273 to 356,000 mg/kg), four to 17 sensitizing elements (8.27-4755.63 mg/kg), and one to seven sensitizing organics (15-382,170 mg/kg). Median numbers and concentrations of irritants and sensitizers were significantly influenced by resin system and AM process type. The presence of undeclared irritants and sensitizers in these resins supports the need for more complete information on product SDSs for comprehensive dermal risk assessments.


Asunto(s)
Seguridad de Productos para el Consumidor , Irritantes , Luces de Curación Dental , Irritantes/toxicidad , Curación por Luz de Adhesivos Dentales , Medición de Riesgo
4.
J Occup Environ Hyg ; 19(5): 281-294, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35289720

RESUMEN

Dental personnel are ranked among the highest risk occupations for exposure to SARS-CoV-2 due to their close proximity to the patient's mouth and many aerosol generating procedures encountered in dental practice. One method to reduce aerosols in dental settings is the use of intraoral evacuation systems. Intraoral evacuation systems are placed directly into a patient's mouth and maintain a dry field during procedures by capturing liquid and aerosols. Although multiple intraoral dental evacuation systems are commercially available, the efficacy of these systems is not well understood. The objectives of this study were to evaluate the efficacy of four dental evacuation systems at mitigating aerosol exposures during simulated ultrasonic scaling and crown preparation procedures. We conducted real-time respirable (PM4) and thoracic (PM10) aerosol sampling during ultrasonic scaling and crown preparation procedures while using four commercially available evacuation systems: a high-volume evacuator (HVE) and three alternative intraoral systems (A, B, C). Four trials were conducted for each system. Respirable and thoracic mass concentrations were measured during procedures at three locations including (1) near the breathing zone (BZ) of the dentist, (2) edge of the dental operatory room approximately 0.9 m away from the mannequin mouth, and (3) hallway supply cabinet located approximately 1.5 m away from the mannequin mouth. Respirable and thoracic mass concentrations measured during each procedure were compared with background concentrations measured in each respective location. Use of System A or HVE reduced thoracic (System A) and respirable (HVE) mass concentrations near the dentist's BZ to median background concentrations most often during the ultrasonic scaling procedure. During the crown preparation, use of System B or HVE reduced thoracic (System B) and respirable (HVE or System B) near the dentist's BZ to median background concentrations most often. Although some differences in efficacy were noted during each procedure and aerosol size fraction, the difference in median mass concentrations among evacuation systems was minimal, ranging from 0.01 to 1.48 µg/m3 across both procedures and aerosol size fractions.


Asunto(s)
COVID-19 , SARS-CoV-2 , Aerosoles , COVID-19/prevención & control , Clínicas Odontológicas , Humanos , Manejo de Especímenes
5.
Artículo en Inglés | MEDLINE | ID: mdl-35982992

RESUMEN

Fused filament fabrication three-dimensional (FFF 3-D) printing is thought to be environmentally sustainable; however, significant amounts of waste can be generated from this technology. One way to improve its sustainability is via distributed recycling of plastics in homes, schools, and libraries to create feedstock filament for printing. Risks from exposures incurred during recycling and reuse of plastics has not been incorporated into life cycle assessments. This study characterized contaminant releases from virgin (unextruded) and recycled plastics from filament production through FFF 3-D printing. Waste polylactic acid (PLA) and acrylonitrile butadiene styrene (ABS) plastics were recycled to create filament; virgin PLA, ABS, high and low density polyethylenes, high impact polystyrene, and polypropylene pellets were also extruded into filament. The release of particles and chemicals into school classrooms was evaluated using standard industrial hygiene methodologies. All tasks released particles that contained hazardous metals (e.g., manganese) and with size capable of depositing in the gas exchange region of the lung, i.e., granulation of waste PLA and ABS (667 to 714 nm) and filament making (608 to 711 nm) and FFF 3-D printing (616 to 731 nm) with waste and virgin plastics. All tasks released vapors, including respiratory irritants and potential carcinogens (benzene and formaldehyde), mucus membrane irritants (acetone, xylenes, ethylbenzene, and methyl methacrylate), and asthmagens (styrene, multiple carbonyl compounds). These data are useful for incorporating risks of exposure to hazardous contaminants in future life cycle evaluations to demonstrate the sustainability and circular economy potential of FFF 3-D printing in distributed spaces.

6.
Am J Respir Crit Care Med ; 202(12): 1678-1688, 2020 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-32673495

RESUMEN

Rationale: Workers' exposure to metalworking fluid (MWF) has been associated with respiratory disease.Objectives: As part of a public health investigation of a manufacturing facility, we performed a cross-sectional study using paired environmental and human sampling to evaluate the cross-pollination of microbes between the environment and the host and possible effects on lung pathology present among workers.Methods: Workplace environmental microbiota were evaluated in air and MWF samples. Human microbiota were evaluated in lung tissue samples from workers with respiratory symptoms found to have lymphocytic bronchiolitis and alveolar ductitis with B-cell follicles and emphysema, in lung tissue samples from control subjects, and in skin, nasal, and oral samples from 302 workers from different areas of the facility. In vitro effects of MWF exposure on murine B cells were assessed.Measurements and Main Results: An increased similarity of microbial composition was found between MWF samples and lung tissue samples of case workers compared with control subjects. Among workers in different locations within the facility, those that worked in the machine shop area had skin, nasal, and oral microbiota more closely related to the microbiota present in the MWF samples. Lung samples from four index cases and skin and nasal samples from workers in the machine shop area were enriched with Pseudomonas, the dominant taxa in MWF. Exposure to used MWF stimulated murine B-cell proliferation in vitro, a hallmark cell subtype found in the pathology of index cases.Conclusions: Evaluation of a manufacturing facility with a cluster of workers with respiratory disease supports cross-pollination of microbes from MWF to humans and suggests the potential for exposure to these microbes to be a health hazard.


Asunto(s)
Aerosoles/efectos adversos , Contaminantes Ocupacionales del Aire/efectos adversos , Instalaciones Industriales y de Fabricación , Microbiota , Pseudomonas pseudoalcaligenes , Trastornos Respiratorios/fisiopatología , Adulto , Microbiología del Aire , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Trastornos Respiratorios/etiología , Estados Unidos
7.
Artículo en Inglés | MEDLINE | ID: mdl-33720803

RESUMEN

Measurement of skin exposure to particles using interception (e.g., cotton gloves) and removal (e.g., wiping) sampling techniques could be inaccurate because these substrates do not have the same topography and adhesion characteristics as skin. The objective of this study was to compare particle transfer and adherence to cotton gloves, cotton gloves with artificial sebum, and a pre-moistened polyvinyl alcohol (PVA) material with bare human skin (fingertip, palm). Experiments were performed with aluminum oxide powder under standardized conditions for three types of surfaces touched, applied loads, contact times, and powder mass levels. In the final mixed model, the fixed effects of substrate, surface type, applied load, and powder mass and their significant two-way interaction terms explained 71% (transfer) and 74% (adherence) of the observed total variance in measurements. For particle mass transfer, compared with bare skin, bias was -77% (cotton glove with sebum) to +197% (PVA material) and for adherence bias ranged from -40% (cotton glove) to +428% (PVA material), which indicated under- and over-sampling by these substrates, respectively. Dermal exposure assessment would benefit from sampling substrates that better reflect human skin characteristics and more accurately estimate exposures. Mischaracterization of dermal exposure has important implications for exposure and risk assessment.


Asunto(s)
Exposición a Riesgos Ambientales/análisis , Piel/metabolismo , Manejo de Especímenes , Adhesividad , Óxido de Aluminio/análisis , Óxido de Aluminio/química , Óxido de Aluminio/metabolismo , Fibra de Algodón , Humanos , Alcohol Polivinílico/química , Polvos/análisis , Polvos/química , Polvos/metabolismo , Absorción Cutánea
8.
Occup Environ Med ; 77(6): 386-392, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32132182

RESUMEN

OBJECTIVES: Four machine manufacturing facility workers had a novel occupational lung disease of uncertain aetiology characterised by lymphocytic bronchiolitis, alveolar ductitis and emphysema (BADE). We aimed to evaluate current workers' respiratory health in relation to job category and relative exposure to endotoxin, which is aerosolised from in-use metalworking fluid. METHODS: We offered a questionnaire and spirometry at baseline and 3.5 year follow-up. Endotoxin exposures were quantified for 16 production and non-production job groups. Forced expiratory volume in one second (FEV1) decline ≥10% was considered excessive. We examined SMRs compared with US adults, adjusted prevalence ratios (aPRs) for health outcomes by endotoxin exposure tertiles and predictors of excessive FEV1 decline. RESULTS: Among 388 (89%) baseline participants, SMRs were elevated for wheeze (2.5 (95% CI 2.1 to 3.0)), but not obstruction (0.5 (95% CI 0.3 to 1.1)). Mean endotoxin exposures (range: 0.09-28.4 EU/m3) were highest for machine shop jobs. Higher exposure was associated with exertional dyspnea (aPR=2.8 (95% CI 1.4 to 5.7)), but not lung function. Of 250 (64%) follow-up participants, 11 (4%) had excessive FEV1 decline (range: 403-2074 mL); 10 worked in production. Wheeze (aPR=3.6 (95% CI 1.1 to 12.1)) and medium (1.3-7.5 EU/m3) endotoxin exposure (aPR=10.5 (95% CI 1.3 to 83.1)) at baseline were associated with excessive decline. One production worker with excessive decline had BADE on subsequent lung biopsy. CONCLUSIONS: Lung function loss and BADE were associated with production work. Relationships with relative endotoxin exposure indicate work-related adverse respiratory health outcomes beyond the sentinel disease cluster, including an incident BADE case. Until causative factors and effective preventive strategies for BADE are determined, exposure minimisation and medical surveillance of affected workforces are recommended.


Asunto(s)
Contaminantes Ocupacionales del Aire/efectos adversos , Bronquiolitis/epidemiología , Enfisema/epidemiología , Endotoxinas/efectos adversos , Enfermedades Profesionales/epidemiología , Exposición Profesional/efectos adversos , Adulto , Anciano , Contaminantes Ocupacionales del Aire/análisis , Bronquiolitis/inducido químicamente , Enfisema/inducido químicamente , Endotoxinas/análisis , Femenino , Volumen Espiratorio Forzado , Humanos , Masculino , Instalaciones Industriales y de Fabricación , Persona de Mediana Edad , National Institute for Occupational Safety and Health, U.S. , Enfermedades Profesionales/inducido químicamente , Exposición Profesional/análisis , Alveolos Pulmonares/patología , Encuestas y Cuestionarios , Estados Unidos
9.
Inhal Toxicol ; 31(13-14): 432-445, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31874579

RESUMEN

Objective: Fused filament fabrication "3-dimensional (3-D)" printing has expanded beyond the workplace to 3-D printers and pens for use by children as toys to create objects.Materials and methods: Emissions from two brands of toy 3-D pens and one brand of toy 3-D printer were characterized in a 0.6 m3 chamber (particle number, size, elemental composition; concentrations of individual and total volatile organic compounds (TVOC)). The effects of print parameters on these emission metrics were evaluated using mixed-effects models. Emissions data were used to model particle lung deposition and TVOC exposure potential.Results: Geometric mean particle yields (106-1010 particles/g printed) and sizes (30-300 nm) and TVOC yields (

Asunto(s)
Contaminación del Aire Interior/análisis , Monitoreo del Ambiente/métodos , Material Particulado/análisis , Juego e Implementos de Juego , Impresión Tridimensional , Compuestos Orgánicos Volátiles/análisis , Niño , Humanos , Tamaño de la Partícula
10.
Am J Ind Med ; 62(11): 927-937, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31461179

RESUMEN

BACKGROUND: A cluster of severe lung disease occurred at a manufacturing facility making industrial machines. We aimed to describe disease features and workplace exposures. METHODS: Clinical, functional, radiologic, and histopathologic features were characterized. Airborne concentrations of thoracic aerosol, metalworking fluid, endotoxin, metals, and volatile organic compounds were measured. Facility airflow was assessed using tracer gas. Process fluids were examined using culture, polymerase chain reaction, and 16S ribosomal RNA sequencing. RESULTS: Five previously healthy male never-smokers, ages 27 to 50, developed chest symptoms from 1995 to 2012 while working in the facility's production areas. Patients had an insidious onset of cough, wheeze, and exertional dyspnea; airflow obstruction (mean FEV1 = 44% predicted) and reduced diffusing capacity (mean = 53% predicted); and radiologic centrilobular emphysema. Lung tissue demonstrated a unique pattern of bronchiolitis and alveolar ductitis with B-cell follicles lacking germinal centers, and significant emphysema for never-smokers. All had chronic dyspnea, three had a progressive functional decline, and one underwent lung transplantation. Patients reported no unusual nonoccupational exposures. No cases were identified among nonproduction workers or in the community. Endotoxin concentrations were elevated in two air samples; otherwise, exposures were below occupational limits. Air flowed from areas where machining occurred to other production areas. Metalworking fluid primarily grew Pseudomonas pseudoalcaligenes and lacked mycobacterial DNA, but 16S analysis revealed more complex bacterial communities. CONCLUSION: This cluster indicates a previously unrecognized occupational lung disease of yet uncertain etiology that should be considered in manufacturing workers (particularly never-smokers) with airflow obstruction and centrilobular emphysema. Investigation of additional cases in other settings could clarify the cause and guide prevention.


Asunto(s)
Bronquiolitis/etiología , Pulmón/patología , Industria Manufacturera , Enfermedades Profesionales/etiología , Exposición Profesional/efectos adversos , Enfisema Pulmonar/etiología , Adulto , Contaminantes Ocupacionales del Aire/efectos adversos , Contaminantes Ocupacionales del Aire/análisis , Endotoxinas/análisis , Humanos , Masculino , Instalaciones Industriales y de Fabricación , Persona de Mediana Edad , Exposición Profesional/análisis , Alveolos Pulmonares/patología , Adulto Joven
11.
J Occup Environ Hyg ; 16(1): 66-77, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30325716

RESUMEN

Indium-tin oxide production has increased greatly in the last 20 years subsequent to increased global demand for touch screens and photovoltaics. Previous studies used measurements of indium in blood as an indicator of indium exposure and observed associations with adverse respiratory outcomes. However, correlations between measurements of blood indium and airborne respirable indium are inconsistent, in part because of the long half-life of indium in blood, but also because respirable indium measurements do not incorporate inhalable indium that can contribute to the observed biological burden. Information is lacking on relationships between respirable and inhalable indium exposure, which have implications for biological indicators like blood indium. The dual IOM sampler includes the foam disc insert and can simultaneously collect respirable and inhalable aerosol. Here, the field performance of the dual IOM sampler was evaluated by comparing performance with the respirable cyclone and traditional IOM for respirable and inhalable indium and dust exposure, respectively. Side-by-side area air samples were collected throughout an indium-tin oxide manufacturing facility. Cascade impactors were used to determine particle size distribution. Several statistical methods were used to evaluate the agreement between the pairs of samplers including calculating the concordance correlation coefficient and its accuracy and precision components. One-way ANOVA was used to evaluate the effect of dust concentration on sampler differences. Respirable indium measurements showed better agreement (concordance correlation coefficient: 0.932) compared to respirable dust measurements (concordance correlation coefficient: 0.777) with significant differences observed in respirable dust measurements. The dual IOM measurements had high agreement with the traditional IOM for inhalable indium (concordance correlation coefficient: 0.997) but lower agreement for inhalable dust (concordance correlation coefficient: 0.886 and accuracy: 0.896) with a significantly large mean bias (-146.9 µg/m3). Dust concentration significantly affected sampler measurements of inhalable dust and inhalable indium. Results from this study suggest that the dual IOM is a useful single sampler for simultaneous measurements of occupational exposure to respirable and inhalable indium.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Monitoreo del Ambiente/instrumentación , Indio/análisis , Exposición por Inhalación/análisis , Polvo/análisis , Instalaciones Industriales y de Fabricación , Exposición Profesional/análisis , Tamaño de la Partícula , Compuestos de Estaño
12.
Indoor Air ; 28(6): 840-851, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30101413

RESUMEN

Fused deposition modeling (FDM™) 3-dimensional printing uses polymer filament to build objects. Some polymer filaments are formulated with additives, though it is unknown if they are released during printing. Three commercially available filaments that contained carbon nanotubes (CNTs) were printed with a desktop FDM™ 3-D printer in a chamber while monitoring total particle number concentration and size distribution. Airborne particles were collected on filters and analyzed using electron microscopy. Carbonyl compounds were identified by mass spectrometry. The elemental carbon content of the bulk CNT-containing filaments was 1.5 to 5.2 wt%. CNT-containing filaments released up to 1010 ultrafine (d < 100 nm) particles/g printed and 106 to 108 respirable (d ~0.5 to 2 µm) particles/g printed. From microscopy, 1% of the emitted respirable polymer particles contained visible CNTs. Carbonyl emissions were observed above the limit of detection (LOD) but were below the limit of quantitation (LOQ). Modeling indicated that, for all filaments, the average proportional lung deposition of CNT-containing polymer particles was 6.5%, 5.7%, and 7.2% for the head airways, tracheobronchiolar, and pulmonary regions, respectively. If CNT-containing polymer particles are hazardous, it would be prudent to control emissions during use of these filaments.


Asunto(s)
Imagenología Tridimensional , Nanotubos de Carbono , Polímeros/química , Monitoreo del Ambiente/métodos , Exposición por Inhalación , Material Particulado/análisis
13.
Inhal Toxicol ; 29(4): 169-178, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28595469

RESUMEN

Inhalation of indium-containing dusts is associated with the development of indium lung disease. Workers may be exposed to several different chemical forms of indium; however, their lung dosimetry is not fully understood. We characterized the physicochemical properties and measured the lung dissolution kinetics of eight indium-containing dusts. Indium dissolution rates in artificial lung fluids spanned two orders of magnitude. We used the International Commission on Radiological Protection (ICRP) human respiratory model (HRTM) to estimate pulmonary indium deposition, retention and biokinetic clearance to blood. For a two-year (median workforce tenure at facility) exposure to respirable-sized particles of the indium materials, modeled indium clearance (>99.99% removed) from the alveolar-interstitial compartment was slow for all dusts; salts would clear in 4 years, sintered indium-tin oxide (ITO) would clear in 9 years, and indium oxide would require 48 years. For this scenario, the ICRP HRTM predicted that indium translocated to blood would be present in that compartment for 3.5-18 years after cessation of exposure, depending on the chemical form. For a 40-year exposure (working lifetime), clearance from the alveolar-interstitial compartment would require 5, 10 and 60 years for indium salts, sintered ITO and indium oxide, respectively and indium would be present in blood for 5-53 years after exposure. Consideration of differences in chemical forms of indium, dissolution rates, alveolar clearance and residence time in blood should be included in exposure assessment and epidemiological studies that rely on measures of total indium in air or blood to derive risk estimates.


Asunto(s)
Polvo/análisis , Indio/química , Modelos Biológicos , Fenómenos Fisiológicos Respiratorios , Sistema Respiratorio/anatomía & histología , Líquidos Corporales , Humanos , Radiometría
14.
J Occup Environ Hyg ; 14(7): 540-550, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28440728

RESUMEN

Printing devices are known to emit chemicals into the indoor atmosphere. Understanding factors that influence release of chemical contaminants from printers is necessary to develop effective exposure assessment and control strategies. In this study, a desktop fused deposition modeling (FDM) 3-dimensional (3-D) printer using acrylonitrile butadiene styrene (ABS) or polylactic acid (PLA) filaments and two monochrome laser printers were evaluated in a 0.5 m3 chamber. During printing, chamber air was monitored for vapors using a real-time photoionization detector (results expressed as isobutylene equivalents) to measure total volatile organic compound (TVOC) concentrations, evacuated canisters to identify specific VOCs by off-line gas chromatography-mass spectrometry (GC-MS) analysis, and liquid bubblers to identify carbonyl compounds by GC-MS. Airborne particles were collected on filters for off-line analysis using scanning electron microscopy with an energy dispersive x-ray detector to identify elemental constituents. For 3-D printing, TVOC emission rates were influenced by a printer malfunction, filament type, and to a lesser extent, by filament color; however, rates were not influenced by the number of printer nozzles used or the manufacturer's provided cover. TVOC emission rates were significantly lower for the 3-D printer (49-3552 µg h-1) compared to the laser printers (5782-7735 µg h-1). A total of 14 VOCs were identified during 3-D printing that were not present during laser printing. 3-D printed objects continued to off-gas styrene, indicating potential for continued exposure after the print job is completed. Carbonyl reaction products were likely formed from emissions of the 3-D printer, including 4-oxopentanal. Ultrafine particles generated by the 3-D printer using ABS and a laser printer contained chromium. Consideration of the factors that influenced the release of chemical contaminants (including known and suspected asthmagens such as styrene and 4-oxopentanal) from a FDM 3-D printer should be made when designing exposure assessment and control strategies.


Asunto(s)
Contaminación del Aire Interior/análisis , Material Particulado/análisis , Impresión Tridimensional , Compuestos Orgánicos Volátiles/análisis , Acrilonitrilo/análisis , Aldehídos/análisis , Butadienos , Cromo/análisis , Monitoreo del Ambiente/métodos , Cetonas/análisis , Poliésteres , Estireno/análisis
15.
Occup Environ Med ; 73(12): 864-867, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27456157

RESUMEN

OBJECTIVE: Occupational exposure to indium compounds including indium-tin oxide (ITO) can result in potentially fatal indium lung disease. We compared plasma, serum and whole blood indium concentrations (InP, InS and InB) from workers at a single ITO production facility to assess the comparability of these matrices used for biological monitoring of indium exposure. METHOD: InP, InS and InB were measured using inductively coupled mass spectrometry from consenting workers at an ITO production facility with specimen collection occurring during June-July 2014. Matched pairs from workers were assessed to determine the matrix relationships using the Pearson correlation, paired t-tests, per cent difference, linear regression and κ statistics. RESULTS: Indium matrices were collected from 80 workers. Mean (SD) InP, InS and InB were 3.48 (3.84), 3.90 (4.15) and 4.66 (5.32) mcg/L, respectively. The InS-InP difference was 14%; InS was higher in all but two workers. InP and InS were highly correlated (r=>0.99). The InB-InS difference was 19%; InB was higher in 85% of workers. The InB-InP difference was 34%; InB was higher in 66% of workers. InB was highly correlated with both InP and InS (r=0.97 and 0.96, respectively). κ Statistics were 0.84, 0.83 and 0.82 for InP, InS and InB, respectively, for individuals with each matrix ≥1 mcg/L (p<0.01). CONCLUSIONS: While all matrices were highly correlated, we encourage the use of InP and InS to reliably compare studies across different populations using different matrices. The higher per cent difference and increased variability of InB may limit its utility in comparisons with InP and InS in different populations.


Asunto(s)
Indio/sangre , Exposición Profesional/análisis , Compuestos de Estaño/sangre , Monitoreo del Ambiente/métodos , Humanos , Instalaciones Industriales y de Fabricación , National Institute for Occupational Safety and Health, U.S. , Plasma/química , Suero/química , Estados Unidos
16.
J Toxicol Environ Health A ; 79(11): 453-65, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27196745

RESUMEN

Desktop three-dimensional (3D) printers are becoming commonplace in business offices, public libraries, university labs and classrooms, and even private homes; however, these settings are generally not designed for exposure control. Prior experience with a variety of office equipment devices such as laser printers that emit ultrafine particles (UFP) suggests the need to characterize 3D printer emissions to enable reliable risk assessment. The aim of this study was to examine factors that influence particulate emissions from 3D printers and characterize their physical properties to inform risk assessment. Emissions were evaluated in a 0.5-m(3) chamber and in a small room (32.7 m(3)) using real-time instrumentation to measure particle number, size distribution, mass, and surface area. Factors evaluated included filament composition and color, as well as the manufacturer-provided printer emissions control technologies while printing an object. Filament type significantly influenced emissions, with acrylonitrile butadiene styrene (ABS) emitting larger particles than polylactic acid (PLA), which may have been the result of agglomeration. Geometric mean particle sizes and total particle (TP) number and mass emissions differed significantly among colors of a given filament type. Use of a cover on the printer reduced TP emissions by a factor of 2. Lung deposition calculations indicated a threefold higher PLA particle deposition in alveoli compared to ABS. Desktop 3D printers emit high levels of UFP, which are released into indoor environments where adequate ventilation may not be present to control emissions. Emissions in nonindustrial settings need to be reduced through the use of a hierarchy of controls, beginning with device design, followed by engineering controls (ventilation) and administrative controls such as choice of filament composition and color.


Asunto(s)
Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Monitoreo del Ambiente , Material Particulado/análisis , Impresión Tridimensional , Tamaño de la Partícula , Ventilación
17.
Am J Ind Med ; 59(7): 522-31, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27219296

RESUMEN

BACKGROUND: Workers manufacturing indium-tin oxide (ITO) are at risk of elevated indium concentration in blood and indium lung disease, but relationships between respirable indium exposures and biomarkers of exposure and disease are unknown. METHODS: For 87 (93%) current ITO workers, we determined correlations between respirable and plasma indium and evaluated associations between exposures and health outcomes. RESULTS: Current respirable indium exposure ranged from 0.4 to 108 µg/m(3) and cumulative respirable indium exposure from 0.4 to 923 µg-yr/m(3) . Plasma indium better correlated with cumulative (rs = 0.77) than current exposure (rs = 0.54) overall and with tenure ≥1.9 years. Higher cumulative respirable indium exposures were associated with more dyspnea, lower spirometric parameters, and higher serum biomarkers of lung disease (KL-6 and SP-D), with significant effects starting at 22 µg-yr/m(3) , reached by 46% of participants. CONCLUSIONS: Plasma indium concentration reflected cumulative respirable indium exposure, which was associated with clinical, functional, and serum biomarkers of lung disease. Am. J. Ind. Med. 59:522-531, 2016. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.


Asunto(s)
Indio/sangre , Enfermedades Pulmonares/inducido químicamente , Exposición Profesional/análisis , Compuestos de Estaño/análisis , Adulto , Contaminantes Ocupacionales del Aire/análisis , Biomarcadores/análisis , Biomarcadores/sangre , Monitoreo del Ambiente , Humanos , Indio/efectos adversos , Enfermedades Pulmonares/diagnóstico , Persona de Mediana Edad , Exposición Profesional/efectos adversos , Ocupaciones , Espirometría , Compuestos de Estaño/efectos adversos
18.
Am J Ind Med ; 58(1): 101-11, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25351791

RESUMEN

BACKGROUND: Healthcare workers have an elevated prevalence of asthma and related symptoms associated with the use of cleaning/disinfecting products. The objective of this study was to identify and characterize cleaning/disinfecting tasks and products used among hospital occupations. METHODS: Workers from 14 occupations at five hospitals were monitored for 216 shifts, and work tasks and products used were recorded at five-minute intervals. The major chemical constituents of each product were identified from safety data sheets. RESULTS: Cleaning and disinfecting tasks were performed with a high frequency at least once per shift in many occupations. Medical equipment preparers, housekeepers, floor strippers/waxers, and endoscopy technicians spent on average 108-177 min/shift performing cleaning/disinfecting tasks. Many occupations used products containing amines and quaternary ammonium compounds for >100 min/shift. CONCLUSIONS: This analysis demonstrates that many occupations besides housekeeping incur exposures to cleaning/disinfecting products, albeit for different durations and using products containing different chemicals.


Asunto(s)
Desinfección/estadística & datos numéricos , Personal de Salud/estadística & datos numéricos , Servicio de Limpieza en Hospital/estadística & datos numéricos , Exposición Profesional/estadística & datos numéricos , Control de Enfermedades Transmisibles/métodos , Detergentes/química , Detergentes/uso terapéutico , Desinfectantes/química , Desinfectantes/uso terapéutico , Desinfección/métodos , Personal de Salud/clasificación , Hospitales , Hospitales de Enseñanza , Humanos , Ficha de Datos de Seguridad de Materiales , New England , Exposición Profesional/análisis , Sudeste de Estados Unidos
19.
Occup Environ Med ; 71(9): 642-50, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25011549

RESUMEN

OBJECTIVES: To identify and summarise volatile organic compound (VOC) exposure profiles of healthcare occupations. METHODS: Personal (n=143) and mobile area (n=207) evacuated canisters were collected and analysed by a gas chromatograph/mass spectrometer to assess exposures to 14 VOCs among 14 healthcare occupations in five hospitals. Participants were volunteers identified by their supervisors. Summary statistics were calculated by occupation. Principal component analysis (PCA) was used to reduce the 14 analyte inputs to five orthogonal factors and identify occupations that were associated with these factors. Linear regressions were used to assess the association between personal and mobile area samples. RESULTS: Exposure profiles differed among occupations; ethanol had the highest geometric mean (GM) among nursing assistants (∼4900 and ∼1900 µg/m(3), personal and area), and 2-propanol had the highest GM among medical equipment preparers (∼4600 and ∼2000 µg/m(3), personal and area). The highest total personal VOC exposures were among nursing assistants (∼9200 µg/m(3)), licensed practical nurses (∼8700 µg/m(3)) and medical equipment preparers (∼7900 µg/m(3)). The influence of the PCA factors developed from personal exposure estimates varied by occupation, which enabled a comparative assessment of occupations. For example, factor 1, indicative of solvent use, was positively correlated with clinical laboratory and floor stripping/waxing occupations and tasks. Overall, a significant correlation was observed (r=0.88) between matched personal and mobile area samples, but varied considerably by analyte (r=0.23-0.64). CONCLUSIONS: Healthcare workers are exposed to a variety of chemicals that vary with the activities and products used during activities. These VOC profiles are useful for estimating exposures for occupational hazard ranking for industrial hygienists as well as epidemiological studies.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Hospitales de Veteranos , Exposición Profesional/análisis , Compuestos Orgánicos Volátiles/análisis , Contaminantes Ocupacionales del Aire/toxicidad , Monitoreo del Ambiente/métodos , Personal de Salud , Humanos , Exposición Profesional/efectos adversos , Análisis de Componente Principal , Análisis de Regresión , Estados Unidos , Compuestos Orgánicos Volátiles/toxicidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA