J Cardiovasc Magn Reson ; 16: 43, 2014 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-24947763

RESUMEN

BACKGROUND: We aimed to assess the feasibility of 3 dimensional (3D) respiratory and ECG gated, gadolinium enhanced magnetic resonance angiography (MRA) on a 3 Tesla (3 T) scanner for imaging pulmonary veins (PV) and left atrium (LA). The impact of heart rate (HR) and rhythm irregularity associated with atrial fibrillation (AF) on image and segmentation qualities were also assessed. METHODS: 101 consecutive patients underwent respiratory and ECG gated (ventricular end systolic window) MRA for pre AF ablation imaging. Image quality (assessed by PV delineation) was scored as 1 = not visualized, 2 = poor, 3 = good and 4 = excellent. Segmentation quality was scored on a similar 4 point scale. Signal to noise ratios (SNRs) were calculated for the LA, LA appendage (LAA), and PV. Contrast to noise ratios (CNRs) were calculated between myocardium and LA, LAA and PV, respectively. Associations between HR/rhythm and quality metrics were assessed. RESULTS: 35 of 101 (34.7%) patients were in AF at time of MRA. 100 (99%) patients had diagnostic studies, and 91 (90.1%) were of good or excellent quality. Overall, mean ± standard deviation (SD) image quality score was 3.40 ± 0.69. Inter observer agreement for image quality scores was substantial, (kappa = 0.68; 95% confidence interval (CI): 0.46, 0.90). Neither HR adjusting for rhythm [odds ratio (OR) = 1.03, 95% CI = 0.98,1.09; p = 0.22] nor rhythm adjusting for HR [OR = 1.25, 95% CI = 0.20, 7.69; p = 0.81] demonstrated association with image quality. Similarly, SNRs and CNRs were largely independent of HR after adjusting for rhythm. Segmentation quality scores were good or excellent for 77.3% of patients: mean ± SD score = 2.91 ± 0.63, and scores did not significantly differ by baseline rhythm (p = 0.78). CONCLUSIONS: 3D respiratory and ECG gated, gadolinium enhanced MRA of the PVs and LA on a 3 T system is feasible during ventricular end systole, achieving high image quality and high quality image segmentation when imported into electroanatomic mapping systems. Quality is independent of HR and heart rhythm for this free breathing, radiation free, alternative strategy to current MRA or CT based approaches, for pre AF ablation imaging of PVs and LA.


Asunto(s)
Fibrilación Atrial/diagnóstico , Técnicas de Imagen Sincronizada Cardíacas , Medios de Contraste , Electrocardiografía , Frecuencia Cardíaca , Angiografía por Resonancia Magnética , Meglumina/análogos & derivados , Compuestos Organometálicos , Venas Pulmonares/patología , Frecuencia Respiratoria , Anciano , Fibrilación Atrial/patología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter , Distribución de Chi-Cuadrado , Estudios de Factibilidad , Femenino , Atrios Cardíacos/patología , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Humanos , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Modelos Logísticos , Masculino , Persona de Mediana Edad , Dinámicas no Lineales , Variaciones Dependientes del Observador , Oportunidad Relativa , Valor Predictivo de las Pruebas , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Venas Pulmonares/cirugía , Reproducibilidad de los Resultados , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA