Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Gastrointest Endosc ; 85(2): 401-408.e2, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27515129

RESUMEN

BACKGROUND AND AIMS: The first small-bowel video-capsule endoscopy (VCE) with 360° panoramic view has been developed recently. This new capsule has wire-free technology, 4 high-frame-rate cameras, and a long-lasting battery life. The aim of the present study was to assess the performance and safety profile of the 360° panoramic-view capsule in a large series of patients from a multicenter clinical practice setting. METHODS: Consecutive patients undergoing a 360° panoramic-view capsule procedure in 7 European Institutions between January 2011 and November 2015 were included. Both technical (ie, technical failures, completion rate) and clinical (ie, indication, findings, retention rate) data were collected by means of a structured questionnaire. VCE findings were classified according to the likelihood of explaining the reason for referral: P0, low; P1, intermediate; P2, high. RESULTS: Of the 172 patients (94 men; median age, 68 years; interquartile range, 53-75), 142 underwent VCE for obscure (32 overt, 110 occult) GI bleeding (OGIB), and 28 for suspected (17) or established (2) Crohn's disease (CD). Overall, 560 findings were detected; 252 were classified as P2. The overall diagnostic yield was 40.1%; 42.2% and 30.0% in patients with OGIB and CD, respectively. The rate of complete enteroscopy was 90.2%. All patients but one, who experienced capsule retention (1/172, 0.6%), excreted and retrieved the capsule. VCE failure occurred in 4 of 172 (2.3%) patients because of technical problems. CONCLUSIONS: This multicenter study, conducted in the clinical practice setting and based on a large consecutive series of patients, showed that the diagnostic yield and safety profile of the 360° panoramic-view capsule are similar to those of forward-view VCEs.


Asunto(s)
Endoscopía Capsular/métodos , Enfermedad de Crohn/diagnóstico , Hemorragia Gastrointestinal/diagnóstico , Intestino Delgado , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
2.
Dig Liver Dis ; 44(12): 1006-11, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22858420

RESUMEN

BACKGROUND: Data about strategies for improving the diagnostic ability of capsule endoscopy readers are lacking. AIM: (1) To evaluate the detection rate and the interobserver agreement among readers with different experience; (2) to verify the impact of a specific training (hands-on training plus expert tutorial) on these parameters. METHODS: 17 readers reviewed 12 videos twice; between the two readings they underwent the training. The identified small bowel findings were described by a simplified version of Structured Terminology and classifies as clinically significant/non-significant. Findings identified by the readers were compared with those identified by three experts (Reference Standard). RESULTS: The Reference Standard identified 26 clinically significant findings. The mean detection rate of overall readers for significant findings was low (about 50%) and did not change after the training (46.2% and 46.4%, respectively). There was no difference in the detection rate among readers with different experience. The interobserver agreement with the Reference Standard in describing significant findings was moderate (k = 0.44; CI95%: 0.39-0.50) and did not change after the training (k = 0.44; CI95%: 0.38-0.49) or stratifying readers according to their experience. CONCLUSIONS: Both the interobserver agreement and the detection rate of significant findings are low, regardless of the readers' experience. Our training did not significantly increase the performance of readers with different experience.


Asunto(s)
Endoscopía Capsular/normas , Competencia Clínica , Enfermedades Intestinales/diagnóstico , Intestino Delgado/patología , Variaciones Dependientes del Observador , Endoscopía Capsular/educación , Humanos , Curva de Aprendizaje , Estándares de Referencia
3.
Eur J Gastroenterol Hepatol ; 22(11): 1380-6, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20173646

RESUMEN

BACKGROUND AND AIM: Data about small bowel capsule endoscopy (SBCE) come from studies involving small and highly selected populations. The study aim was to describe extent of use, indications, results, complications, and practical issues of SBCE in clinical practice in a Northern Italian Region (Lombardia). MATERIALS AND METHODS: Twenty-three out of 29 invited centers fulfilled a specific questionnaire. RESULTS: Between 2001 and 2008, 2921 procedures were performed and both the number of centers performing SBCE (from 5 to 29) and the number of SBCE (from 7.2 to 69.2 per month) increased steadily. The main indications for SBCE were: obscure gastrointestinal bleeding (OGIB) (43.4%), unexplained anemia (23.9%), suspected Crohn's disease (7.8%) and abdominal pain (5.3%). Overall, SBCE was positive in 50% of cases, negative in 36% and undefined in 14%. The highest diagnostic yields were observed in patients with OGIB (62.5%), polypoid syndromes (74.1%), known (54.8%) or suspected (47.3%) inflammatory bowel disease, while the yields were low in patients examined for chronic diarrhea (27.4%) and abdominal pain (14.9%), 61 patients (2.1%) experienced capsule retention. Thirty-two of them eventually excreted the capsule naturally while endoscopic or surgical retrieval was necessary in 29 (1%) (in two because of obstruction). CONCLUSION: Over a period of 7 years the use of SBCE in Lombardia increased steadily confirming, in clinical practice, a high diagnostic yield and an acceptable safety profile.


Asunto(s)
Endoscopía Capsular/estadística & datos numéricos , Enfermedades Intestinales/diagnóstico , Intestino Delgado/patología , Pautas de la Práctica en Medicina/estadística & datos numéricos , Endoscopía Capsular/efectos adversos , Encuestas de Atención de la Salud , Humanos , Enfermedades Intestinales/patología , Italia , Valor Predictivo de las Pruebas , Medición de Riesgo , Encuestas y Cuestionarios , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA