Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Adv Nurs ; 2023 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-38054397

RESUMEN

AIM: To gain staff feedback on the implementation and impact of a novel ambulatory monitoring system to support coronavirus patient management on an isolation ward. DESIGN: Qualitative service evaluation. METHODS: Semi-structured interviews were conducted with 15 multidisciplinary isolation ward staff in the United Kingdom between July 2020 and May 2021. Interviews were audio-recorded, transcribed and analysed using thematic analysis. FINDINGS: Adopting Innovation to Assist Patient Safety was identified as the overriding theme. Three interlinked sub-themes represent facets of how the system supported patient safety. Patient Selection was developed throughout the pandemic, as clinical staff became more confident in choosing which patients would benefit most. Trust In the System described how nurses coped with discrepancies between the ambulatory system and ward observation machines. Finally, Resource Management examined how, once trust was built, staff perceived the ambulatory system assisted with caseload management. This supported efficient personal protective equipment resource use by reducing the number of isolation room entries. Despite these reported benefits, face-to-face contact was still highly valued, despite the risk of coronavirus exposure. CONCLUSION: Hospital wards should consider using ambulatory monitoring systems to support caseload management and patient safety. Patients in isolation rooms or at high risk of deterioration may particularly benefit from this additional monitoring. However, these systems should be seen as an adjunct to nursing care, not a replacement. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: Nurses valued ambulatory monitoring as a means of ensuring the safety of patients at risk of deterioration and prioritizing their workload. IMPACT: The findings of this research will be useful to all those developing or considering implementation of ambulatory monitoring systems in hospital wards. REPORTING METHOD: This manuscript follows the Consolidated criteria for Reporting Qualitative Research (COREQ) guidelines with inclusion of relevant SQUIRE guidelines for reporting quality improvement. PATIENT OR PUBLIC CONTRIBUTION: No Patient or Public Contribution.

2.
Nurs Crit Care ; 28(4): 566-573, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-34783137

RESUMEN

BACKGROUND: As survivorship following critical illness improves, there is greater focus on maximizing recovery. As well as physical effects, critical illness often results in cognitive impairments such as delirium, anxiety, or disorientation. In other populations, such as delirium, non-pharmacological approaches to manage these conditions are preferred, including re-orientation and ensuring personal care needs are met. Cognitive rehabilitation is also well documented for patients with neuropsychological deficits. Treatments include memory aids, compensation strategies, and functional execution. In other hospital populations, games and activities have been utilized to optimize patient engagement, stimulation, and aid recovery, but it is considered an emerging therapy in intensive care. AIMS: This service evaluation aimed to gather multidisciplinary team members' perceptions of the use of games based therapy (GBT) in critical care, including patient engagement and acceptability in clinical practice. STUDY DESIGN: A UK-based single-centre qualitative service evaluation. Purposive sampling was used to identify interviewees within an adult intensive care who had experience of using a recently implemented GBT intervention. Qualitative data were collected through semi-structured interviews, which were recorded and transcribed verbatim. Data were analysed using thematic analysis. RESULTS: Eight staff members across the multidisciplinary team were interviewed. One overarching theme of humanizing health care was identified, with three sub-themes of enhancing recovery, non-physical components of care, and bespoke tailoring. In addition, further recommendations for development of the service were summarized. CONCLUSION: GBT was well received by staff in clinical practice. It was described as a supportive adjunct to traditional care and rehabilitation, enhancing staff-patient relationships. While it was recognized it may not suit all patients, GBT has the potential to enhance cognitive and physical recovery.


Asunto(s)
Enfermedad Crítica , Delirio , Adulto , Humanos , Enfermedad Crítica/terapia , Cuidados Críticos , Grupo de Atención al Paciente , Percepción , Investigación Cualitativa
3.
Nurs Crit Care ; 2023 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-37642162

RESUMEN

BACKGROUND: Survivors of critical care are at risk of long-term disability from musculoskeletal (MSK) impairments. These can have a biopsychosocial impact on the patient and their families with a reduction in health-related quality of life, increased health care utilization, caregiving roles and associated psychological distress. AIMS: To understand the experiences of patients living with MSK impairments following critical illness, and family and health care professionals supporting them, to inform the development of a future intervention to improve MSK health following critical illness. STUDY DESIGN: A four-site qualitative case study approach will be taken, with each of the four hospital sites and associated community services representing a case site. We will conduct semi-structured interviews with 10-15 patients/family members and 10-15 health care professionals about their experiences of MSK impairment following critical illness. Interviews will be audio recorded, transcribed verbatim and analysed using reflexive thematic analysis within a descriptive phenomenological approach. Alongside interview data, analysis of publicly available policy documentation, patient-facing materials and information from service leads at the four sites will be conducted. Discourse analysis will be used for this case study documentation. RESULTS: This protocol describes a qualitative study exploring the experiences of patients living with MSK impairments following critical illness, and the family and health care professionals supporting them. RELEVANCE TO CLINICAL PRACTICE: Data analysis will illuminate their experiences and enable data richness to contribute to the qualitative body of evidence of intensive care unit (ICU) survivors. These findings will inform the development of a complex intervention for MSK rehabilitation after critical illness.

4.
Crit Care Med ; 50(7): 1083-1092, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35245235

RESUMEN

OBJECTIVES: Out-of-hours discharge from ICU to the ward is associated with increased in-hospital mortality and ICU readmission. Little is known about why this occurs. We map the discharge process and describe the consequences of out-of-hours discharge to inform practice changes to reduce the impact of discharge at night. DESIGN: This study was part of the REcovery FoLlowing intensive CarE Treatment mixed methods study. We defined out-of-hours discharge as 16:00 to 07:59 hours. We undertook 20 in-depth case record reviews where in-hospital death after ICU discharge had been judged "probably avoidable" in previous retrospective structured judgment reviews, and 20 where patients survived. We conducted semistructured interviews with 55 patients, family members, and staff with experience of ICU discharge processes. These, along with a stakeholder focus group, informed ICU discharge process mapping using the human factors-based functional analysis resonance method. SETTING: Three U.K. National Health Service hospitals, chosen to represent different hospital settings. SUBJECTS: Patients discharged from ICU, their families, and staff involved in their care. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Out-of-hours discharge was common. Patients and staff described out-of-hours discharge as unsafe due to a reduction in staffing and skill mix at night. Patients discharged out-of-hours were commonly discharged prematurely, had inadequate handover, were physiologically unstable, and did not have deterioration recognized or escalated appropriately. We identified five interdependent function keys to facilitating timely ICU discharge: multidisciplinary team decision for discharge, patient prepared for discharge, bed meeting, bed manager allocation of beds, and ward bed made available. CONCLUSIONS: We identified significant limitations in out-of-hours care provision following overnight discharge from ICU. Transfer to the ward before 16:00 should be facilitated where possible. Our work highlights changes to help make day time discharge more likely. Where discharge after 16:00 is unavoidable, support systems should be implemented to ensure the safety of patients discharged from ICU at night.


Asunto(s)
Atención Posterior , Daño del Paciente , Cuidados Críticos/métodos , Mortalidad Hospitalaria , Humanos , Unidades de Cuidados Intensivos , Alta del Paciente , Estudios Retrospectivos , Medicina Estatal
5.
J Med Internet Res ; 24(2): e28890, 2022 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-35166690

RESUMEN

BACKGROUND: Commercially available wearable (ambulatory) pulse oximeters have been recommended as a method for managing patients at risk of physiological deterioration, such as active patients with COVID-19 disease receiving care in hospital isolation rooms; however, their reliability in usual hospital settings is not known. OBJECTIVE: We report the performance of wearable pulse oximeters in a simulated clinical setting when challenged by motion and low levels of arterial blood oxygen saturation (SaO2). METHODS: The performance of 1 wrist-worn (Wavelet) and 3 finger-worn (CheckMe O2+, AP-20, and WristOx2 3150) wearable, wireless transmission-mode pulse oximeters was evaluated. For this, 7 motion tasks were performed: at rest, sit-to-stand, tapping, rubbing, drinking, turning pages, and using a tablet. Hypoxia exposure followed, in which inspired gases were adjusted to achieve decreasing SaO2 levels at 100%, 95%, 90%, 87%, 85%, 83%, and 80%. Peripheral oxygen saturation (SpO2) estimates were compared with simultaneous SaO2 samples to calculate the root-mean-square error (RMSE). The area under the receiver operating characteristic curve was used to analyze the detection of hypoxemia (ie, SaO2<90%). RESULTS: SpO2 estimates matching 215 SaO2 samples in both study phases, from 33 participants, were analyzed. Tapping, rubbing, turning pages, and using a tablet degraded SpO2 estimation (RMSE>4% for at least 1 device). All finger-worn pulse oximeters detected hypoxemia, with an overall sensitivity of ≥0.87 and specificity of ≥0.80, comparable to that of the Philips MX450 pulse oximeter. CONCLUSIONS: The SpO2 accuracy of wearable finger-worn pulse oximeters was within that required by the International Organization for Standardization guidelines. Performance was degraded by motion, but all pulse oximeters could detect hypoxemia. Our findings support the use of wearable, wireless transmission-mode pulse oximeters to detect the onset of clinical deterioration in hospital settings. TRIAL REGISTRATION: ISRCTN Registry 61535692; http://www.isrctn.com/ISRCTN61535692. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1136/bmjopen-2019-034404.


Asunto(s)
COVID-19 , Dispositivos Electrónicos Vestibles , Humanos , Hipoxia/diagnóstico , Oximetría , Reproducibilidad de los Resultados , SARS-CoV-2
6.
J Adv Nurs ; 78(3): 810-822, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34655093

RESUMEN

AIMS: To understand current experiences of vital signs monitoring of patients and clinical staff on a surgical ward, and views on the introduction of wearable ambulatory monitoring into the general ward environment. DESIGN: Qualitative study. METHODS: Semi-structured interviews using topic guides were conducted with 15 patients and 15 nurses on a surgical ward between July 2018 and August 2019. The concept of ambulatory wearable devices for clinical monitoring was introduced at the end of the interview. RESULTS: Three interconnected themes were identified. Vital sign data as evidence for escalation, examined nurses' use of data to support escalation of care and the implications for patients perceived to be deteriorating who have not reached the threshold for escalation. The second theme, Trustworthiness of vital sign data, described nurses' practice of using manual measurements to recheck or confirm automated vital signs readings when concerned. The final theme, finding a balance between continuous and intermittent monitoring, both patients and nurses agreed that although continuous monitoring may improve safety and reassurance, these needed to be balanced with multiple limitations. Factors to be considered included noise pollution, comfort, and impact on patient mobility and independence. Introduction of the concept of ambulatory wearable devices was viewed positively by both groups as offering solutions to some of the issues identified with traditional monitoring. However, most agreed that this would not be suitable for all patients and should not replace direct nurse/patient contact. CONCLUSION: Both patients and staff identified the benefits of continuous monitoring to improve patient safety but, due to limitations, use should be carefully considered and patient-centred. IMPACT: Feedback from nurses and patients suggests there is scope for ambulatory monitoring systems to be integrated into the hospital environment; however, both groups emphasized these should not add more noise to the ward nor replace direct nursing contact.


Asunto(s)
Personal de Enfermería en Hospital , Dispositivos Electrónicos Vestibles , Humanos , Monitoreo Fisiológico , Seguridad del Paciente , Investigación Cualitativa , Signos Vitales
7.
J Adv Nurs ; 78(10): 3371-3384, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35986583

RESUMEN

AIMS: To explore registered nurses' experiences of patient safety in intensive care during COVID-19. DESIGN: A qualitative interview study informed by constructivism. METHOD: Semi-structured interviews were conducted and audio-recorded with 19 registered nurses who worked in intensive care during COVID-19 between May and July 2021. Interviews were transcribed verbatim and thematically analysed utilizing framework. RESULTS: Two key themes were identified. 'On a war footing'-an unprecedented situation which describes the situation nurses faced, and the actions are taken to prepare for the safe delivery of care. 'Doing the best we can'-Safe Delivery of Care which describes the ramifications of the actions taken on short- and long-term patient safety including organization of care, missed and suboptimal care and communication. Both themes were embedded in the landscape of Staff Well-being and Peer Support. CONCLUSION: Nurses reported an increase in patient safety risks which they attributed to the dilution of skill mix and fragmentation of care. Nurses demonstrated an understanding of the holistic and long-term impacts on patient safety and recovery from critical illness. IMPACT: This study explored the perceived impact of COVID-19 on patient safety in intensive care from a nursing perspective. Dilution of skill mix, where specialist critical care registered nurses were diluted with registered nurses with no critical care experience, and the fragmentation of care was perceived to lead to reduced quality of care and increased adverse events and risk of harm which were not consistently formally reported. Furthermore, nurses demonstrated a holistic and long-term appreciation of patient safety. These findings should be considered as part of future nursing workforce modelling and patient safety strategies by intensive care leaders and managers. No public or patient contribution to this study. The study aims and objectives were developed in collaboration with health care professionals.


Asunto(s)
COVID-19 , Enfermeras y Enfermeros , Cuidados Críticos , Humanos , Seguridad del Paciente , Investigación Cualitativa
8.
Crit Care ; 25(1): 10, 2021 01 06.
Artículo en Inglés | MEDLINE | ID: mdl-33407702

RESUMEN

BACKGROUND: Over 138,000 patients are discharged to hospital wards from intensive care units (ICUs) in England, Wales and Northern Ireland annually. More than 8000 die before leaving hospital. In hospital-wide populations, 6.7-18% of deaths have some degree of avoidability. For patients discharged from ICU, neither the proportion of avoidable deaths nor the reasons underlying avoidability have been determined. We undertook a retrospective case record review within the REFLECT study, examining how post-ICU ward care might be improved. METHODS: A multi-centre retrospective case record review of 300 consecutive post-ICU in-hospital deaths, between January 2015 and March 2018, in 3 English hospitals. Trained multi-professional researchers assessed the degree to which each death was avoidable and determined care problems using the established Structured Judgement Review method. RESULTS: Agreement between reviewers was good (weighted Kappa 0.77, 95% CI 0.64-0.88). Discharge from an ICU for end-of-life care occurred in 50/300 patients. Of the remaining 250 patients, death was probably avoidable in 20 (8%, 95% CI 5.0-12.1) and had some degree of avoidability in 65 (26%, 95% CI 20.7-31.9). Common problems included out-of-hours discharge from ICU (168/250, 67.2%), suboptimal rehabilitation (167/241, 69.3%), absent nutritional planning (76/185, 41.1%) and incomplete sepsis management (50/150, 33.3%). CONCLUSIONS: The proportion of deaths in hospital with some degree of avoidability is higher in patients discharged from an ICU than reported in hospital-wide populations. Extrapolating our findings suggests around 550 probably avoidable deaths occur annually in hospital following ICU discharge in England, Wales and Northern Ireland. This avoidability occurs in an elderly frail population with complex needs that current strategies struggle to meet. Problems in post-ICU care are rectifiable but multi-disciplinary. TRIAL REGISTRATION: ISRCTN14658054.


Asunto(s)
Unidades de Cuidados Intensivos/estadística & datos numéricos , Mortalidad/tendencias , Alta del Paciente/normas , Anciano , Anciano de 80 o más Años , Enfermedad Crítica/epidemiología , Enfermedad Crítica/mortalidad , Femenino , Humanos , Unidades de Cuidados Intensivos/organización & administración , Masculino , Persona de Mediana Edad , Alta del Paciente/estadística & datos numéricos , Estudios Retrospectivos , Reino Unido/epidemiología
9.
Crit Care ; 25(1): 351, 2021 09 28.
Artículo en Inglés | MEDLINE | ID: mdl-34583742

RESUMEN

BACKGROUND: Timely recognition of the deteriorating inpatient remains challenging. Wearable monitoring systems (WMS) may augment current monitoring practices. However, there are many barriers to implementation in the hospital environment, and evidence describing the clinical impact of WMS on deterioration detection and patient outcome remains unclear. OBJECTIVE: To assess the impact of vital-sign monitoring on detection of deterioration and related clinical outcomes in hospitalised patients using WMS, in comparison with standard care. METHODS: A systematic search was conducted in August 2020 using MEDLINE, Embase, CINAHL, Cochrane Database of Systematic Reviews, CENTRAL, Health Technology Assessment databases and grey literature. Studies comparing the use of WMS against standard care for deterioration detection and related clinical outcomes in hospitalised patients were included. Deterioration related outcomes (primary) included unplanned intensive care admissions, rapid response team or cardiac arrest activation, total and major complications rate. Other clinical outcomes (secondary) included in-hospital mortality and hospital length of stay. Exploratory outcomes included alerting system parameters and clinical trial registry information. RESULTS: Of 8706 citations, 10 studies with different designs met the inclusion criteria, of which 7 were included in the meta-analyses. Overall study quality was moderate. The meta-analysis indicated that the WMS, when compared with standard care, was not associated with significant reductions in intensive care transfers (risk ratio, RR 0.87; 95% confidence interval, CI 0.66-1.15), rapid response or cardiac arrest team activation (RR 0.84; 95% CI 0.69-1.01), total (RR 0.77; 95% CI 0.44-1.32) and major (RR 0.55; 95% CI 0.24-1.30) complications prevalence. There was also no statistically significant association with reduced mortality (RR 0.48; 95% CI 0.18-1.29) and hospital length of stay (mean difference, MD - 0.09; 95% CI - 0.43 to 0.44). CONCLUSION: This systematic review indicates that there is no current evidence that implementation of WMS impacts early deterioration detection and associated clinical outcomes, as differing design/quality of available studies and diversity of outcome measures make it difficult to reach a definite conclusion. Our narrative findings suggested that alarms should be adjusted to minimise false alarms and promote rapid clinical action in response to deterioration. PROSPERO Registration number: CRD42020188633 .


Asunto(s)
Monitoreo Fisiológico , Signos Vitales , Dispositivos Electrónicos Vestibles , Deterioro Clínico , Hospitalización , Humanos , Monitoreo Fisiológico/métodos , Evaluación de Resultado en la Atención de Salud , Signos Vitales/fisiología
10.
J Med Internet Res ; 23(9): e27547, 2021 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-34524087

RESUMEN

BACKGROUND: The standard of care in general wards includes periodic manual measurements, with the data entered into track-and-trigger charts, either on paper or electronically. Wearable devices may support health care staff, improve patient safety, and promote early deterioration detection in the interval between periodic measurements. However, regulatory standards for ambulatory cardiac monitors estimating heart rate (HR) and respiratory rate (RR) do not specify performance criteria during patient movement or clinical conditions in which the patient's oxygen saturation varies. Therefore, further validation is required before clinical implementation and deployment of any wearable system that provides continuous vital sign measurements. OBJECTIVE: The objective of this study is to determine the agreement between a chest-worn patch (VitalPatch) and a gold standard reference device for HR and RR measurements during movement and gradual desaturation (modeling a hypoxic episode) in a controlled environment. METHODS: After the VitalPatch and gold standard devices (Philips MX450) were applied, participants performed different movements in seven consecutive stages: at rest, sit-to-stand, tapping, rubbing, drinking, turning pages, and using a tablet. Hypoxia was then induced, and the participants' oxygen saturation gradually reduced to 80% in a controlled environment. The primary outcome measure was accuracy, defined as the mean absolute error (MAE) of the VitalPatch estimates when compared with HR and RR gold standards (3-lead electrocardiography and capnography, respectively). We defined these as clinically acceptable if the rates were within 5 beats per minute for HR and 3 respirations per minute (rpm) for RR. RESULTS: Complete data sets were acquired for 29 participants. In the movement phase, the HR estimates were within prespecified limits for all movements. For RR, estimates were also within the acceptable range, with the exception of the sit-to-stand and turning page movements, showing an MAE of 3.05 (95% CI 2.48-3.58) rpm and 3.45 (95% CI 2.71-4.11) rpm, respectively. For the hypoxia phase, both HR and RR estimates were within limits, with an overall MAE of 0.72 (95% CI 0.66-0.78) beats per minute and 1.89 (95% CI 1.75-2.03) rpm, respectively. There were no significant differences in the accuracy of HR and RR estimations between normoxia (≥90%), mild (89.9%-85%), and severe hypoxia (<85%). CONCLUSIONS: The VitalPatch was highly accurate throughout both the movement and hypoxia phases of the study, except for RR estimation during the two types of movements. This study demonstrated that VitalPatch can be safely tested in clinical environments to support earlier detection of cardiorespiratory deterioration. TRIAL REGISTRATION: ISRCTN Registry ISRCTN61535692; https://www.isrctn.com/ISRCTN61535692.


Asunto(s)
Signos Vitales , Dispositivos Electrónicos Vestibles , Humanos , Hipoxia/diagnóstico , Monitoreo Fisiológico , Frecuencia Respiratoria
11.
Nurs Crit Care ; 25(3): 171-178, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31833178

RESUMEN

BACKGROUND: "Failure to Rescue" includes failing to prevent avoidable patient deterioration and death. Despite its use, delays in care escalation still affect patient outcomes. AIMS AND OBJECTIVE: The aim of this qualitative service evaluation was to map the barriers and facilitators to the escalation of care in the acute ward setting and identify those that are modifiable. DESIGN: A total of 55 hours of qualitative observations were completed to capture care escalation events. These were conducted at two hospital sites in one National Health Service trust. METHODS: Observations were iterative, with research team meetings being used to discuss the data and future methods. Field notes were analysed thematically by two researchers, extracting data on barriers and facilitators to escalation of care. RESULTS: Clinical nursing staff challenged the sensitivity and specificity of Early Warning Scores, describing tool failings in certain clinical scenarios. Staff did not escalate based on the alerting Early Warning Scores alone but used other clinical factors, such as bleeding, which are not necessarily captured in the scoring systems. Staff frequently did not re-escalate low-level scores. Patient and non-patient factors identified as posing barriers to escalation were complex care needs, patient outlier status, and involvement of multiple care teams. Factors negatively affecting the chain of communication during escalation were team tension, staffing levels, and inadequate handover. CONCLUSION: This service evaluation identified barriers and facilitators to the escalation of care in the acute ward setting. Unlike other studies, we found that re-escalation or tracking of deterioration was problematic. Patients identified as being at a higher risk of escalation failure included complex patients, outliers, and patients with multiple care teams. RELEVANCE TO CLINICAL PRACTICE: This service evaluation demonstrates continuing health care communication barriers. Patient groups (complex patients and outliers) risk process failures during escalation. This can be applied in clinical practice by staff anticipating problems in these patients, documenting clear escalation pathways.


Asunto(s)
Deterioro Clínico , Comunicación , Toma de Decisiones , Equipo Hospitalario de Respuesta Rápida , Medicina Estatal , Hospitales , Humanos , Investigación Cualitativa , Reino Unido
18.
J Adv Nurs ; 72(8): 1851-62, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26990704

RESUMEN

AIMS: To identify the practical challenges encountered when using wearable monitors for patients discharged from the intensive care unit. BACKGROUND: Patients discharged from intensive care units are a high-risk group that might benefit from continuing observation using 'wearable' monitors to enable faster identification of physiological deterioration and facilitate timely clinical action. This area of technological innovation is of key interest to nurses who manage this group of patients. DESIGN: A prospective observational study. METHODS: An observational study conducted in 2013-2014 used wearable monitors to record continuous observations for patients discharged from an intensive care unit to develop a predictive model of patients likely to deteriorate. Screening data for study eligibility and case report form data to assess monitor tolerance and comfort were collected daily and analysed using Microsoft Access. RESULTS/FINDINGS: Patients (n = 2704) were discharged from an intensive care unit during the study, 208 consented to wearing the monitor. Of the 192 included in analysis, 130 (67·7%) removed the monitor before the trial finished. Reasons cited for removal included 'discomfort and irritation' 61 (31·8%) and 'feeling too unwell' 8 (4·2%). Five hundred seventeen patients were screened following adaption of the wearable monitor. Despite design changes, 56 (10·8%) patients were unable to wear monitors for reasons related to their anatomy or condition. Of 124 patients, 65 patients (52·4%) who were approached refused participation. CONCLUSION: Work is needed to understand wireless monitor comfort and design for acutely unwell patients. Product design needs to develop further, so patients are catered for in flexibility of monitor placement and improved comfort for long-term wear.


Asunto(s)
Unidades de Cuidados Intensivos , Monitoreo Fisiológico , Alta del Paciente , Dispositivos Electrónicos Vestibles , Humanos , Estudios Prospectivos
19.
Nurs Crit Care ; 26(4): 219-221, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34189803
20.
Nurs Crit Care ; 26(6): 417-420, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34783139
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA