Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Radiology ; 311(1): e231991, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38687218

RESUMEN

Background Digital breast tomosynthesis (DBT) is often inadequate for screening women with a personal history of breast cancer (PHBC). The ongoing prospective Tomosynthesis or Contrast-Enhanced Mammography, or TOCEM, trial includes three annual screenings with both DBT and contrast-enhanced mammography (CEM). Purpose To perform interim assessment of cancer yield, stage, and recall rate when CEM is added to DBT in women with PHBC. Materials and Methods From October 2019 to December 2022, two radiologists interpreted both examinations: Observer 1 reviewed DBT first and then CEM, and observer 2 reviewed CEM first and then DBT. Effects of adding CEM to DBT on incremental cancer detection rate (ICDR), cancer type and node status, recall rate, and other performance characteristics of the primary radiologist decisions were assessed. Results Among the participants (mean age at entry, 63.6 years ± 9.6 [SD]), 1273, 819, and 227 women with PHBC completed year 1, 2, and 3 screening, respectively. For observer 1, year 1 cancer yield was 20 of 1273 (15.7 per 1000 screenings) for DBT and 29 of 1273 (22.8 per 1000 screenings; ICDR, 7.1 per 1000 screenings [95% CI: 3.2, 13.4]) for DBT plus CEM (P < .001). Year 2 plus 3 cancer yield was four of 1046 (3.8 per 1000 screenings) for DBT and eight of 1046 (7.6 per 1000 screenings; ICDR, 3.8 per 1000 screenings [95% CI: 1.0, 7.6]) for DBT plus CEM (P = .001). Year 1 recall rate for observer 1 was 103 of 1273 (8.1%) for (incidence) DBT alone and 187 of 1273 (14.7%) for DBT plus CEM (difference = 84 of 1273, 6.6% [95% CI: 5.3, 8.1]; P < .001). Year 2 plus 3 recall rate was 40 of 1046 (3.8%) for DBT and 92 of 1046 (8.8%) for DBT plus CEM (difference = 52 of 1046, 5.0% [95% CI: 3.7, 6.3]; P < .001). In 18 breasts with cancer detected only at CEM after integration of both observers, 13 (72%) cancers were invasive (median tumor size, 0.6 cm) and eight of nine (88%) with staging were N0. Among 1883 screenings with adequate reference standard, there were three interval cancers (one at the scar, two in axillae). Conclusion CEM added to DBT increased early breast cancer detection each year in women with PHBC, with an accompanying approximately 5.0%-6.6% recall rate increase. Clinical trial registration no. NCT04085510 © RSNA, 2024 Supplemental material is available for this article.


Asunto(s)
Neoplasias de la Mama , Medios de Contraste , Mamografía , Humanos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Mamografía/métodos , Estudios Prospectivos , Persona de Mediana Edad , Detección Precoz del Cáncer/métodos , Anciano , Intensificación de Imagen Radiográfica/métodos , Mama/diagnóstico por imagen
2.
J Magn Reson Imaging ; 58(3): 951-962, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36583628

RESUMEN

BACKGROUND: Diffusion-weighted imaging (DWI) may allow for breast cancer screening MRI without a contrast injection. Multishot methods improve prone DWI of the breasts but face different challenges in the supine position. PURPOSE: To establish a multishot DWI (msDWI) protocol for supine breast MRI and to evaluate the performance of supine vs. prone msDWI. STUDY TYPE: Prospective. POPULATION: Protocol optimization: 10 healthy women (ages 22-56), supine vs. prone: 24 healthy women (ages 22-62) and five women (ages 29-61) with breast tumors. FIELD STRENGTH/SEQUENCE: 3-T, protocol optimization msDWI: free-breathing (FB) 2-shots, FB 4-shots, respiratory-triggered (RT) 2-shots, RT 4-shots, supine vs. prone: RT 4-shot msDWI, T2-weighted fast-spin echo. ASSESSMENT: Protocol optimization and supine vs. prone: three observers performed an image quality assessment of sharpness, aliasing, distortion (vs. T2), perceived SNR, and overall image quality (scale of 1-5). Apparent diffusion coefficients (ADCs) in fibroglandular tissue (FGT) and breast tumors were measured. STATISTICAL TESTS: Effect of study variables on dichotomized ratings (4/5 vs. 1/2/3) and FGT ADCs were assessed with mixed-effects logistic regression. Interobserver agreement utilized Gwet's agreement coefficient (AC). Lesion ADCs were assessed by Bland-Altman analysis and concordance correlation (ρc ). P value <0.05 was considered statistically significant. RESULTS: Protocol optimization: 4-shots significantly improved sharpness and distortion; RT significantly improved sharpness, aliasing, perceived SNR, and overall image quality. FGT ADCs were not significantly different between shots (P = 0.812), FB vs. RT (P = 0.591), or side (P = 0.574). Supine vs. prone: supine images were rated significantly higher for sharpness, aliasing, and overall image quality. FGT ADCs were significantly higher supine; lesion ADCs were highly correlated (ρc  = 0.92). DATA CONCLUSION: Based on image quality, supine msDWI outperformed prone msDWI. Lesion ADCs were highly correlated between the two positions, while FGT ADCs were higher in the supine position. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Neoplasias de la Mama , Imagen de Difusión por Resonancia Magnética , Humanos , Femenino , Estudios Prospectivos , Posición Prona , Imagen de Difusión por Resonancia Magnética/métodos , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados , Neoplasias de la Mama/diagnóstico por imagen , Imagen Eco-Planar/métodos
3.
J Breast Imaging ; 6(3): 288-295, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38557759

RESUMEN

Breast hemangiomas are rare benign vascular lesions. In a previously performed review of approximately 10,000 breast surgical pathology results, roughly 0.15% (15/~10 000) were hemangiomas. Hemangiomas are more frequent in women and have a documented age distribution of 1.5 to 82 years. They are most often subcutaneous or subdermal and anterior to the anterior mammary fascia but may rarely be seen in the pectoralis muscles or chest wall. On imaging, breast hemangiomas typically present as oval or round masses, often measuring less than 2.5 cm, with circumscribed or mostly circumscribed, focally microlobulated margins, equal or high density on mammography, and variable echogenicity on US. Calcifications, including phleboliths, can be seen. Color Doppler US often shows hypovascularity or avascularity. MRI appearance can vary, although hemangiomas are generally T2 hyperintense and T1 hypointense with variable enhancement. Pathologic findings vary by subtype, which include perilobular, capillary, cavernous, and venous hemangiomas. If core biopsy pathology results are benign, without atypia, and concordant with imaging and clinical findings, surgical excision is not routinely indicated. Because of histopathologic overlap with well-differentiated or low-grade angiosarcomas, surgical excision may be necessary for definitive diagnosis. Findings that are more common with angiosarcomas include size greater than 2 cm, hypervascularity on Doppler US, irregular shape, and invasive growth pattern.


Asunto(s)
Neoplasias de la Mama , Hemangioma , Imagen por Resonancia Magnética , Humanos , Femenino , Hemangioma/patología , Hemangioma/diagnóstico por imagen , Neoplasias de la Mama/patología , Neoplasias de la Mama/diagnóstico por imagen , Mamografía/métodos , Ultrasonografía Mamaria/métodos , Mama/patología , Mama/diagnóstico por imagen
4.
J Clin Oncol ; 41(13): 2403-2415, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36626696

RESUMEN

PURPOSE: To assess diagnostic performance of digital breast tomosynthesis (DBT) alone or combined with technologist-performed handheld screening ultrasound (US) in women with dense breasts. METHODS: In an institutional review board-approved, Health Insurance Portability and Accountability Act-compliant multicenter protocol in western Pennsylvania, 6,179 women consented to three rounds of annual screening, interpreted by two radiologist observers, and had appropriate follow-up. Primary analysis was based on first observer results. RESULTS: Mean participant age was 54.8 years (range, 40-75 years). Across 17,552 screens, there were 126 cancer events in 125 women (7.2/1,000; 95% CI, 5.9 to 8.4). In year 1, DBT-alone cancer yield was 5.0/1,000, and of DBT+US, 6.3/1,000, difference 1.3/1,000 (95% CI, 0.3 to 2.1; P = .005). In years 2 + 3, DBT cancer yield was 4.9/1,000, and of DBT+US, 5.9/1,000, difference 1.0/1,000 (95% CI, 0.4 to 1.5; P < .001). False-positive rate increased from 7.0% for DBT in year 1 to 11.5% for DBT+US and from 5.9% for DBT in year 2 + 3 to 9.7% for DBT+US (P < .001 for both). Nine cancers were seen only by double reading DBT and one by double reading US. Ten interval cancers (0.6/1,000 [95% CI, 0.2 to 0.9]) were identified. Despite reduction in specificity, addition of US improved receiver operating characteristic curves, with area under receiver operating characteristic curve increasing from 0.83 for DBT alone to 0.92 for DBT+US in year 1 (P = .01), with smaller improvements in subsequent years. Of 6,179 women, across all 3 years, 172/6,179 (2.8%) unique women had a false-positive biopsy because of DBT as did another 230/6,179 (3.7%) women because of US (P < .001). CONCLUSION: Overall added cancer detection rate of US screening after DBT was modest at 19/17,552 (1.1/1,000; CI, 0.5- to 1.6) screens but potentially overcomes substantial increases in false-positive recalls and benign biopsies.


Asunto(s)
Neoplasias de la Mama , Mamografía , Humanos , Femenino , Adulto , Persona de Mediana Edad , Anciano , Masculino , Mamografía/métodos , Densidad de la Mama , Estudios Prospectivos , Detección Precoz del Cáncer/métodos , Tamizaje Masivo/métodos
5.
J Breast Imaging ; 4(4): 408-412, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35915844

RESUMEN

Nipple adenomas (NAs) are benign neoplasms composed of papillary hyperplasia of the epithelium of the major lactiferous ducts. Patients with NA may report bloody nipple discharge and clinically may resemble Paget disease, raising concern for malignancy. Mammographically, NAs are often occult. US can show a hypervascular circumscribed mass centered within the nipple with varying echogenicity. Diagnosis is usually made on punch biopsy or excision, but breast radiologists should be aware of this entity. Malignancy can be found elsewhere in the ipsilateral or contralateral breast, or very rarely may directly extend to involve an NA, but published experience with concurrent malignancies is small. We describe the radiologic-pathologic correlation of NAs.

6.
J Breast Imaging ; 3(2): 176-189, 2021 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38424825

RESUMEN

OBJECTIVE: Using terms adapted from the BI-RADS Mammography and MRI lexicons, we trained radiologists to interpret contrast-enhanced mammography (CEM) and assessed reliability of their description and assessment. METHODS: A 60-minute presentation on CEM and terminology was reviewed independently by 21 breast imaging radiologist observers. For 21 CEM exams with 31 marked findings, observers recorded background parenchymal enhancement (BPE) (minimal, mild, moderate, marked), lesion type (oval/round or irregular mass, or non-mass enhancement), intensity of enhancement (none, weak, medium, strong), enhancement quality (none, homogeneous, heterogeneous, rim), and BI-RADS assessment category (2, 3, 4A, 4B, 4C, 5). "Expert" consensus of 3 other radiologists experienced in CEM was developed. Kappa statistic was used to assess agreement between radiologists and expert consensus, and between radiologists themselves, on imaging feature categories and final assessments. Reproducibility of specific feature descriptors was assessed as fraction of consensus-concordant responses. RESULTS: Radiologists demonstrated moderate agreement for BPE, (mean kappa, 0.43; range, 0.05-0.69), and lowest reproducibility for "minimal." Agreement was substantial for lesion type (mean kappa, 0.70; range, 0.47-0.93), moderate for intensity of enhancement (mean kappa, 0.57; range, 0.44-0.76), and moderate for enhancement quality (mean kappa, 0.59; range, 0.20-0.78). Agreement on final assessment was fair (mean kappa, 0.26; range, 0.09-0.44), with BI-RADS category 3 the least reproducible. Decision to biopsy (BI-RADS 2-3 vs 4-5) showed moderate agreement with consensus (mean kappa, 0.54; range, -0.06-0.87). CONCLUSION: With minimal training, agreement for description of CEM findings by breast imaging radiologists was comparable to other BI-RADS lexicons.

7.
J Breast Imaging ; 3(5): 542-555, 2021 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-38424951

RESUMEN

Selection of a localization method for nonpalpable breast lesions offers an opportunity for institutions to seek multidisciplinary input to promote value-based, patient-centered care. The diverse range of nonpalpable breast and axillary pathologies identified through increased utilization of screening mammography often necessitates image-guided preoperative localization for accurate lesion identification and excision. Preoperative localization techniques for breast and axillary lesions have evolved to include both wire and nonwire methods, the latter of which include radioactive seeds, radar reflectors, magnetic seeds, and radiofrequency identification tag localizers. There are no statistically significant differences in surgical outcomes when comparing wire and nonwire localization devices. Factors to consider during selection and adoption of image-guided localization systems include physician preference and ease of use, workflow efficiency, and patient satisfaction.

8.
J Breast Imaging ; 3(3): 301-311, 2021 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38424776

RESUMEN

OBJECTIVE: For breast US interpretation, to assess impact of computer-aided diagnosis (CADx) in original mode or with improved sensitivity or specificity. METHODS: In this IRB approved protocol, orthogonal-paired US images of 319 lesions identified on screening, including 88 (27.6%) cancers (median 7 mm, range 1-34 mm), were reviewed by 9 breast imaging radiologists. Each observer provided BI-RADS assessments (2, 3, 4A, 4B, 4C, 5) before and after CADx in a mode-balanced design: mode 1, original CADx (outputs benign, probably benign, suspicious, or malignant); mode 2, artificially-high-sensitivity CADx (benign or malignant); and mode 3, artificially-high-specificity CADx (benign or malignant). Area under the receiver operating characteristic curve (AUC) was estimated under each modality and for standalone CADx outputs. Multi-reader analysis accounted for inter-reader variability and correlation between same-lesion assessments. RESULTS: AUC of standalone CADx was 0.77 (95% CI: 0.72-0.83). For mode 1, average reader AUC was 0.82 (range 0.76-0.84) without CADx and not significantly changed with CADx. In high-sensitivity mode, all observers' AUCs increased: average AUC 0.83 (range 0.78-0.86) before CADx increased to 0.88 (range 0.84-0.90), P < 0.001. In high-specificity mode, all observers' AUCs increased: average AUC 0.82 (range 0.76-0.84) before CADx increased to 0.89 (range 0.87-0.92), P < 0.0001. Radiologists responded more frequently to malignant CADx cues in high-specificity mode (42.7% vs 23.2% mode 1, and 27.0% mode 2, P = 0.008). CONCLUSION: Original CADx did not substantially impact radiologists' interpretations. Radiologists showed improved performance and were more responsive when CADx produced fewer false-positive malignant cues.

9.
Plast Reconstr Surg ; 146(4): 409e-413e, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32969997

RESUMEN

Breast reconstruction remains an important field in plastic surgery, with most procedures using implants and/or autologous tissue. Few series report on experience with fat grafting as the primary form of breast reconstruction. The present article describes a new method of breast reconstruction using a three-dimensional absorbable mesh construct-or Lotus scaffold-and autologous fat grafting. A retrospective review was performed for all patients who underwent breast reconstruction using the Lotus scaffold and autologous fat grafting. Postoperative mammograms and magnetic resonance imaging scans were analyzed. Tissue specimens collected at subsequent procedures were harvested and stained with hematoxylin and eosin for histologic evaluation. Lastly, compression testing of the scaffold was performed using a tensiometer and digital tracking technology. Twenty-two patients underwent reconstruction of 28 breasts using the Lotus scaffold and autologous fat grafting between February of 2015 and February of 2018. Average follow-up was 19 months. All patients were satisfied with final breast shape and size. Mean patient age was 60.5 years and the average body mass index was 28 kg/m. Patients required on average two fat grafting sessions to achieve a successful result (range, zero to four). Postoperative mammography and magnetic resonance imaging showed robust adipose tissue in the breast with a slowly resorbing mesh and no oil cysts or calcifications. Histologic evaluation showed the presence of fat tissue around the scaffold and no evidence of capsule formation. Compression testing revealed the Lotus scaffold to be compliant with a high-resilience profile. The Lotus scaffold with autologous fat grafting is a viable method for breast reconstruction, giving the patient an autologous reconstruction with less morbidity compared to free tissue transfer. CLINICAL QUESTION/LEVEL OF EVIDENCE:: Therapeutic, IV.


Asunto(s)
Implantes Absorbibles , Tejido Adiposo/trasplante , Mamoplastia/métodos , Mallas Quirúrgicas , Ingeniería de Tejidos/métodos , Andamios del Tejido , Anciano , Femenino , Humanos , Mamoplastia/instrumentación , Persona de Mediana Edad , Estudios Retrospectivos , Trasplante Autólogo
10.
Acad Radiol ; 27(7): 969-976, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31495761

RESUMEN

RATIONALE AND OBJECTIVES: To preliminarily asses if Contrast Enhanced Digital Mammography (CEDM) can accurately reduce biopsy rates for soft tissue BI-RADS 4A or 4B lesions. MATERIALS AND METHODS: Eight radiologists retrospectively and independently reviewed 60 lesions in 54 consenting patients who underwent CEDM under Health Insurance Portability and Accountability Act compliant institutional review board-approved protocols. Readers provided Breast Imaging Reporting & Data System ratings sequentially for digital mammography/digital breast tomosynthesis (DM/DBT), then with ultrasound, then with CEDM for each lesion. Area under the curve (AUC), true positive rates and false positive rates, positive predictive values and negative predictive values were calculated. Statistical analysis accounting for correlation between lesion-examinations and between-reader variability was performed using OR/DBM (for SAS v.3.0), generalized linear mixed model for binary data (proc glimmix, SAS v.9.4, SAS Institute, Cary North Carolina), and bootstrap. RESULTS: The cohort included 49 benign, two high-risk and nine cancerous lesions in 54 women aged 34-74 (average 50) years. Reader-averaged AUC for CEDM was significantly higher than DM/DBT alone (0.85 versus 0.66, p < 0.001) or with US (0.85 versus 0.75, p = 0.001). CEDM increased true positive rates from 0.74 under DB/DBT, and 0.89 with US, to 0.90 with CEDM, (p = 0.019 DM/DBT versus CEDM, p = 0.78 DM/DBT + US versus CEDM) and decreased false positive rates from 0.47 using DM/DBT and 0.61 with US to 0.39 with CEDM (p = 0.017 DM/DBT versus CEDM, p = 0.001 DM/DBT+ US versus CEDM). For an expected cancer rate of 10%, CEDM positive predictive values was 20.5% (95% CI: 16%-27%) and negative predictive values 98.3% (95% CI: 96%-100%). CONCLUSION: Addition of CEDM for evaluation of low-moderate suspicion soft tissue breast lesions can substantially reduce biopsy of benign lesions without compromising cancer detection.


Asunto(s)
Neoplasias de la Mama , Biopsia , Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Humanos , Mamografía , Persona de Mediana Edad , North Carolina , Estudios Retrospectivos
11.
World J Hepatol ; 4(2): 35-42, 2012 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-22400084

RESUMEN

AIM: To present a dedicated series of transjugular intrahepatic porto-systemic shunts (TIPS) in the elderly since data is sparse on this population group. METHODS: A retrospective review was performed of patients at least 65 years of age who underwent TIPS at our institutions between 1997 and 2010. Twenty-five patients were referred for TIPS. We deemed that 2 patients were not considered appropriate candidates due to their markedly advanced liver disease. Of the 23 patients suitable for TIPS, the indications for TIPS placement was portal hypertension complicated by refractory ascites alone (n = 9), hepatic hydrothorax alone (n = 2), refractory ascites and hydrothorax (n = 1), gastrointestinal bleeding alone (n = 8), gastrointestinal bleeding and ascites (n = 3). RESULTS: Of these 23 attempted TIPS procedure patients, 21 patients had technically successful TIPS procedures. A total of 29 out of 32 TIPS procedures including revisions were successful in 21 patients with a mean age of 72.1 years (range 65-82 years). Three of the procedures were unsuccessful attempts at TIPS and 8 procedures were successful revisions of our existing TIPS. Sixteen of 21 patients who underwent successful TIPS (excluding 5 patients lost to follow-up) were followed for a mean of 14.7 mo. Ascites and/or hydrothorax was controlled following technically successful procedures in 12 of 13 patients. Bleeding was controlled following technically successful procedures in 10 out of 11 patients. CONCLUSION: We have demonstrated that TIPS is an effective procedure to control refractory complications of portal hypertension in elderly patients.

SELECCIÓN DE REFERENCIAS