Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Lab Anim ; 43(4): 333-7, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19505938

RESUMEN

Vascular ultrasound is a reliable non-invasive tool used for the routine assessment of vascular flow and patency in human recipients. We describe the use at three different time points (immediately, 1 week and 4 weeks postsurgery) of ultrasound studies and its validation by angiographic studies in 37 swine undergoing carotid graft replacement. We calculated predictive values (>92%), sensitivity (>85%) and specificity (>92%) with high results at all time points. Ultrasound appeared as an accessible non-invasive technique, providing rapid, safe, repeatable and reliable results. It is an excellent alternative to angiography, avoiding risks inherent to invasive methods and therefore contributing to animal welfare.


Asunto(s)
Oclusión de Injerto Vascular/veterinaria , Procedimientos Quirúrgicos Mínimamente Invasivos/veterinaria , Flujo Sanguíneo Regional/fisiología , Cirugía Veterinaria/métodos , Ultrasonografía Doppler/veterinaria , Grado de Desobstrucción Vascular/fisiología , Animales , Prótesis Vascular/veterinaria , Implantación de Prótesis Vascular/veterinaria , Arterias Carótidas/patología , Arterias Carótidas/cirugía , Femenino , Oclusión de Injerto Vascular/diagnóstico por imagen , Angiografía por Resonancia Magnética/veterinaria , Valor Predictivo de las Pruebas , Estudios Prospectivos , Porcinos
2.
Eur Surg Res ; 40(4): 333-40, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18303269

RESUMEN

BACKGROUND AND AIM: The undersizing of the bypass graft diameter compared to native artery changes blood flow characteristics and velocity which may affect conduit neo-endothelialization, intimal hyperplasia reaction and patency. The aim of this study was to evaluate conduit neoendothelialization, intimal hyperplasia reaction and patency results between undersized and matched ePTFE grafts. MATERIAL AND METHODS: In 16 male Sprague-Dawley rats, undersized (1-mm internal diameter) and matched (2-mm internal diameter) ePTFE grafts were anastomosed end-to-end in the infrarenal abdominal aorta. Blood flow volume per minute was measured and wall shear stress was calculated for each group. After 3 weeks of follow-up, angiography was performed via the left carotid artery just before sacrifice. Conduit neoendothelialization and intimal hyperplasia reaction were measured by computer-assisted morphometry. RESULTS: Wall shear stress was 8 times higher for the undersized group (840.56 vs. 105.07 mPa). Three weeks after implantation, conduit neoendothelialization was better in matched grafts compared to undersized grafts (441 vs. 574 microm, p = 0.008). Intimal hyperplasia reaction was similar for both groups (8.7 vs. 6.7 microm(2)/microm for undersized and matched grafts, respectively). Patency rate was 7/8 for undersized and 8/8 for matched ePTFE grafts. CONCLUSION: Although the graft patency and the intimal hyperplasia reaction were not different between the two groups after 3 weeks, matched grafts had a significantly better endothelialization compared to undersized grafts. This short-term beneficial effect may influence long-term patency results.


Asunto(s)
Aorta Abdominal/cirugía , Prótesis Vascular , Endotelio Vascular/fisiología , Regeneración/fisiología , Túnica Íntima/fisiología , Grado de Desobstrucción Vascular/fisiología , Animales , Aorta Abdominal/patología , Aorta Abdominal/fisiología , Aortografía , Arteriopatías Oclusivas/cirugía , Fenómenos Biomecánicos , Endotelio Vascular/patología , Masculino , Politetrafluoroetileno , Ratas , Ratas Sprague-Dawley
3.
Int J Artif Organs ; 31(3): 244-51, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18373318

RESUMEN

BACKGROUND: Muscular counterpulsation (MCP) was developed for circulatory assistance by stimulation of peripheral skeletal muscles. We report on a clinical MCP study in patients with and without chronic heart failure (CHF). METHODS AND RESULTS: MCP treatment was applied (30 patients treated, 25 controls, all under optimal therapy) for 30 minutes during eight days by an ECG-triggered, battery-powered, portable pulse generator with skin electrodes inducing light contractions of calf and thigh muscles, sequentially stimulated at early diastole. Hemodynamic parameters (ECG, blood pressure and echocardiography) were measured one day before and one day after the treatment period in two groups: Group 1 (9 MCP, 11 no MCP) with ejection fraction (EF) above 40% and Group 2 (21 MCP, 14 no MCP) below 40%. In Group 2 (all patients suffering from CHF) mean EF increased by 21% (p<0.001) and stroke volume by 13% (p<0.001), while end systolic volume decreased by 23% (p<0.001). In Group 1, the increase in EF (6%) and stroke volume (8%) was also significant (p<0.05) but less pronounced than in Group 2. Physical exercise duration and walking distance increased in Group 2 by 56% and 72%, respectively. CONCLUSIONS: Noninvasive MCP treatment for eight days substantially improves cardiac function and physical performance in patients with CHF.


Asunto(s)
Contrapulsación/métodos , Insuficiencia Cardíaca/terapia , Músculo Esquelético/fisiología , Adulto , Electrocardiografía , Prueba de Esfuerzo , Femenino , Insuficiencia Cardíaca/fisiopatología , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
4.
Int J Artif Organs ; 30(5): 407-14, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17551904

RESUMEN

BACKGROUND: Skeletal muscular counterpulsation (MCP) has been used as a new noninvasive technique for treatment of low cardiac output. The MCP method is based on ECG-triggered skeletal muscle stimulation. The purpose of the present study was to evaluate acute hemodynamic changes induced by MCP in the experimental animal. METHODS: Eight anaesthetized pigs (43+/-4 kg) were studied at rest and after IV â-blockade (10 mg propranolol) before and after MCP. Muscular counterpulsation was performed on both thighs using trains (75 ms duration) of multiple biphasic electrical impulses with a width of 1 ms and a frequency of 200 Hz at low (10 V) and high (30 V) amplitude. ECG-triggering was used to synchronize stimulation to a given time point. LV pressure-volume relations were determined using the conductance catheter. After baseline measurements, MCP was carried out for 10 minutes at low and high stimulation amplitude. The optimal time point for MCP was determined from LV pressure-volume loops using different stimulation time points during systole and diastole. Best results were observed during end-systole and, therefore, this time point was used for stimulation. RESULTS: Under control conditions, MCP was associated with a significant decrease in pulmonary vascular resistance (-18%), a decrease in systemic vascular resistance (-11%) and stroke work index (-4%), whereas cardiac index (+2%) and ejection fraction (+6%) increased slightly. Pressure-volume loops showed a leftward shift with a decrease in end-systolic volume. After â-blockade, cardiac function decreased (HR, MAP, EF, dP/dt max), but it improved with skeletal muscle stimulation (HR +10% and CI +17%, EF +5%). There was a significant decrease in pulmonary (-19%) and systemic vascular resistance (-29%). CONCLUSIONS: In the animal model, ECG-triggered skeletal muscular counterpulsation is associated with a significant improvement in cardiac function at baseline and after IV â-blockade. Thus, MCP represents a new, non-invasive technique which improves cardiac function by diastolic compression of the peripheral arteries and veins, with a decrease in systemic vascular resistance and increase in cardiac output.


Asunto(s)
Gasto Cardíaco Bajo/terapia , Contrapulsación , Corazón/fisiopatología , Animales , Presión Sanguínea , Gasto Cardíaco Bajo/fisiopatología , Estimulación Eléctrica , Electrocardiografía , Frecuencia Cardíaca , Músculo Esquelético , Volumen Sistólico , Sus scrofa , Resistencia Vascular
5.
Int J Artif Organs ; 29(10): 990-9, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17211821

RESUMEN

BACKGROUND: Patency of small synthetic bypass grafts is inferior compared to autologous grafts for revascularization procedures. Titanium coating of foreign surfaces has shown to decrease thrombogenicity, enhance biocompatibility and promote adhesion of endothelial cells. The aim of this study was to test the effect of titanium coating of small diameter ePTFE grafts on short term patency, neo-endothelialization and neointimal proliferation. METHODS: Bilateral carotid graft interposition was performed in 5 pigs with uncoated (n=5) and titanium-coated (n=5) ePTFE grafts (internal diameter=4 mm, length=5 cm), thus each pig served as its own control. At the end of the study (30 +/- 3 days), patency and stenosis severity was assessed by carotid angiography. Animals were sacrificed and grafts were excised for histology and scanning electron microscopy. Morphometry of histologic sections was carried out to determine neointimal proliferation and percentage of neo-endothelial coverage. RESULTS: Patency rate was 80% for uncoated and titanium-coated grafts. Quantitative angiography did not show any significant difference in lumen size between two groups. Morphometry revealed a significantly higher cellular coverage with CD31 positive endothelial cells for titanium-coated (84 +/- 19%) than uncoated grafts (48 +/- 26%, p<0.001). There was a non significant trend (p=0.112) towards increased neointimal proliferation in titanium-coated (94 +/- 61 micron2/micron) compared to uncoated grafts (60 +/- 57 micron2/micron). CONCLUSIONS: Patency rate in uncoated and titanium-coated ePTFE grafts is similar at one month. However, titanium coated grafts show a significant improvement in neo-endothelialization compared to uncoated grafts.


Asunto(s)
Prótesis Vascular , Materiales Biocompatibles Revestidos , Oclusión de Injerto Vascular/prevención & control , Titanio , Animales , Implantación de Prótesis Vascular/instrumentación , Arterias Carótidas , Oclusión de Injerto Vascular/patología , Microscopía Electrónica de Rastreo , Politetrafluoroetileno , Porcinos
6.
Int J Artif Organs ; 28(10): 993-1002, 2005 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16288437

RESUMEN

AIMS: Patency failure of small vascular synthetic grafts is still a major problem for coronary and peripheral revascularization. Thus, three new surface coatings of small synthetic grafts were tested in an acute pig model to evaluate their thrombogenicity (extracorporeal arterio-venous shunt) and in a chronic rat model to evaluate the tissue reaction they induced (subcutaneous implantation). METHODS: In five domestic pigs (25-30 kg) an extracorporeal femoro-femoral arterio-venous shunt model was used. The study protocol included first a non-heparinized perfusion sequence followed by graft perfusion after 10,000 UI iv heparin. Grafts were perfused for 3 and 9 minutes. The following coatings were tested on ePTFE grafts: poly-propylene sulphide (PPS)--poly-ethylene glycol (PEG) (wet and dry applications) as well as carbon. Two sets of control were used, one dry and one wet (vehicle only). After perfusion grafts were examined by scanning electron microscopy for semi-quantitative assessment (score 0-3) of cellular and microthrombi deposition. To assess tissue compatibility, pieces of each material were implanted subcutaneously in 16 Wistar rats. At 2, 4, 8, 12 weeks four animals each were sacrificed for semi-quantitative (score 0-3) histologic evaluation of tissue reaction. RESULTS: In the pig model, cellular deposition and microthrombi formation increased over time. In non- heparinized animals, the coatings did not improve the surface characteristics, since they did not prevent microthrombi formation and cellular deposition. In heparinized animals, thrombogenicity was lowest in coated grafts,especially in PPS -PEG dry (p<0.05), and highest in controls. Cell deposition was lowest in PPS-PEG dry, but this difference was not statistically significant vs.controls. In the rat model,no significant differences of the tissue reaction could be shown between materials. CONCLUSION: While all coatings failed to add any benefit for lowering tissue reaction, surface coating with PPS -PEG (dry application) reduced thrombogenicity significantly (in heparinized animals) and thus appears to be promising for improving graft patency of small synthetic vascular prostheses.


Asunto(s)
Prótesis Vascular , Arteria Femoral/patología , Polietilenglicoles/química , Polipropilenos/química , Politetrafluoroetileno/química , Trombosis/patología , Trombosis/prevención & control , Animales , Materiales Biocompatibles Revestidos/química , Arteria Femoral/cirugía , Ensayo de Materiales , Ratas , Ratas Wistar , Porcinos , Resultado del Tratamiento
7.
Semin Hematol ; 33(2 Suppl 2): 75-6; discussion 77, 1996 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-8723588

RESUMEN

The optimum dosage of subcutaneous (s.c.) epoetin alfa was assessed in a double-blind study in 31 patients scheduled for cardiac surgery. Patients received a total of four doses of either epoetin alfa 150 IU/kg (n = 11), epoetin alfa 300 IU/kg (n = 10), or placebo (n = 10) administered as single s.c. injections at weekly intervals starting 23 days prior to surgery. AB was collected with isovolemic replacement prior to each of the first three doses of medication. During the AB donation period, Hb levels decreased significantly (P < .05) from baseline to surgery in the placebo group (16.5%), compared with no significant decrease in either of the epoetin alfa groups (8.1% and 9.7% in the 150 IU/kg and 300 IU/kg groups, respectively). In addition, the difference between groups with regard to the decrease in Hb level reached statistical significance (P < .05) for the 150 IU/kg group versus placebo. Epoetin alfa treatment was also associated with significantly higher reticulocyte counts and serum erythropoietin levels in the preoperative period compared with placebo.


Asunto(s)
Transfusión de Sangre Autóloga , Procedimientos Quirúrgicos Cardíacos , Eritropoyesis/efectos de los fármacos , Eritropoyetina/farmacología , Transfusión Sanguínea/estadística & datos numéricos , Transfusión de Sangre Autóloga/estadística & datos numéricos , Relación Dosis-Respuesta a Droga , Epoetina alfa , Eritropoyetina/administración & dosificación , Humanos , Inyecciones Subcutáneas , Hierro/administración & dosificación , Complicaciones Posoperatorias , Premedicación , Proteínas Recombinantes , Resultado del Tratamiento
8.
J Heart Lung Transplant ; 12(2): 271-82, 1993.
Artículo en Inglés | MEDLINE | ID: mdl-8476901

RESUMEN

Traditionally, detection of heart rejection after heart transplantation is based on histologic grading of endomyocardial biopsy specimens. The value of magnetic resonance spectroscopy for determining heart rejection was assessed in rejecting and nonrejecting isografts and allografts using energy-rich phosphate spectroscopy. In 46 rats a heterotopic abdominal heart transplantation was performed, and animals were divided into the following groups: six isografts (no rejection), five untreated allografts (severe rejection), and 35 immunosuppressed allografts (mild to moderate rejection). One week after transplantation magnetic resonance spectroscopy was performed, and data were correlated to histologic findings (rejection grades according to Stanford and the New International Working Formulation classifications and relative volume of viable myocardium). Magnetic resonance spectroscopy allows detection of moderate to severe rejection with significant alterations in the energy-rich phosphates such as a decrease in the ratio of phosphocreatine/inorganic phosphate, phosphomonoester/inorganic phosphate, and beta-adenosine triphosphate/inorganic phosphate. A significant correlation was found between spectroscopic changes (phosphocreatine/inorganic phosphate) and histologic rejection (correlation coefficient r = 0.47, p < 0.005) and/or the amount of relative volume of viable myocardium and phosphocreatine/inorganic phosphate (r = 0.58) or beta-adenosine triphosphate/inorganic phosphate (r = 0.63), respectively. In conclusion magnetic resonance spectroscopy permits detection of moderate to severe degrees of heart rejection with a sensitivity of 85% and a specificity of 61%. Changes in the energy-rich phosphates correlate with the histologic grading of heart rejection and the relative volume of viable myocardium. Magnetic resonance spectroscopy appeared to be a valid technique for detecting myocardial rejection after heart transplantation in the reported experimental model.


Asunto(s)
Rechazo de Injerto/diagnóstico , Trasplante de Corazón , Espectroscopía de Resonancia Magnética , Miocardio/química , Adenosina Trifosfato/análisis , Animales , Rechazo de Injerto/patología , Concentración de Iones de Hidrógeno , Miocardio/patología , Fosfocreatina/análisis , Ratas , Sensibilidad y Especificidad , Trasplante Isogénico
9.
Surgery ; 113(1): 55-8, 1993 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8417489

RESUMEN

Twenty-one patients who underwent a four-compartment fasciotomy between January 1, 1986, and December 31, 1987, were revisited with respect to venous calf-pump function 32 to 56 months (mean, 46.2 months) after fasciotomy. Enrollment criteria consisted of an intact motor innervation, palpable pedal pulses, the absence of venous hypertension, and deep venous thrombosis before and during the treatment requiring fasciotomy and unimpaired ankle and knee joint function. None of the patients showed signs of chronic venous hypertension at assessment. Ambulatory strain-gauge plethysmography revealed no significant difference in recovery time and refilling volume values between the two limbs of each patient (p > 0.1) and between limbs in which fasciotomy was performed and those of normal subjects (p > 0.1). Color flow duplex scanning revealed patent popliteal veins with normal respiration-induced phasic flow pattern and absent reflux in all patients. All visible calf veins were patent, compressible, and without morphologic alterations. The fasciotomy wound was closed by delayed skin suture (the fascia remaining divided) in 48% and by skin grafts of the lateral incision in 52% of the patients, without significant difference in recovery time and refilling volume values (p > 0.1) at assessment. Fasciotomy does not lead to venous calf-pump dysfunction, irrespective of whether the wound is closed by delayed suture or skin grafts.


Asunto(s)
Síndromes Compartimentales/cirugía , Fasciotomía , Pierna/irrigación sanguínea , Adolescente , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pletismografía , Procedimientos Quirúrgicos Operativos/métodos , Venas/fisiopatología
10.
Surgery ; 111(4): 363-8, 1992 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-1557683

RESUMEN

BACKGROUND: Unsuccessful vascular repair may further preexisting limb ischemia and thus increase the risk of revascularization procedures. METHODS: The results of 94 primary major amputations (group A) have been analyzed and compared with 112 secondary ablations (group B) carried out after failed revascularization efforts. All patients suffered from chronic critical ischemia (grades III and IV) of the lower extremities. In group A the severity of ischemic symptoms was more pronounced (trophic changes in 80% vs 66% in group B), and a preponderance for older age, diabetes mellitus, and incidence of cardiac failure and cerebrovascular insufficiency was evident. RESULTS: In patients undergoing secondary amputation the final transection level was adversely affected by preceding unsuccessful reconstructive attempts. In spite of the better risk profile, 30% of patients in group B were subjected to above-knee amputation compared with 13% of patients in group A. The aggravated limb ischemia caused by graft failure is reflected by the decrease of the mean ankle systolic pressure index from 0.27 to 0.13 (before and after failed revascularization attempts). Although more amputations at the below-knee level were performed initially in group A, primary wound healing was obtained among these subjects in 68% of patients (compared with only 39% for patients in group B). CONCLUSIONS: In a substantial number of cases preexisting limb ischemia may be promoted by failed attempts at vascular reconstruction, thus leading to severe wound healing complications and a higher level of amputation.


Asunto(s)
Amputación Quirúrgica , Arteriosclerosis/cirugía , Isquemia/cirugía , Anciano , Amputación Quirúrgica/rehabilitación , Miembros Artificiales , Humanos , Pierna/irrigación sanguínea , Complicaciones Posoperatorias , Resultado del Tratamiento , Cicatrización de Heridas
11.
Ann Thorac Surg ; 70(1): 212-7, 2000 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-10921710

RESUMEN

BACKGROUND: Bloodflow measurements are of major clinical importance for quality control in vascular surgery. They allow detection of low-flow situations which may influence outcome adversely. The purpose of the present study was to validate three different flow systems for measuring absolute blood flow. METHODS: Measurements were performed in an experimental flow model using arteries and veins and blood or saline at two different temperatures. As a reference method true flow was measured by volume sampling. RESULTS: Correlation coefficients between transit time flow and true flow measurements ranged between 0.71 and 0.92. Systematic overestimation and underestimation of transit time flow were observed, but after second-order correction all correlations were excellent, ranging from 0.93 to 0.95 irrespective of flow medium and temperature. CONCLUSIONS: Transit time flow measurements are exact and reproducible. Second-order correction yields good accuracy and high precision, with minimal differences among the three systems evaluated.


Asunto(s)
Velocidad del Flujo Sanguíneo , Reología/instrumentación , Diseño de Equipo , Estudios de Evaluación como Asunto , Modelos Lineales , Factores de Tiempo
12.
Ann Thorac Surg ; 66(3): 1097-100, 1998 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-9769011

RESUMEN

BACKGROUND: A low-flow situation in arterial and venous grafts has been associated with high rates of perioperative infarction and mortality. This study was designed to look at intraoperative graft flow and resistance in patients with coronary artery disease. METHODS: Coronary artery bypass graft flow was measured in 46 patients. Transit-time flow was used for coronary flow measurements at rest as well as after maximal vasodilation with adenosine infusion. RESULTS: Forty-three of the 46 patients showed normal internal mammary artery graft flow (>20 mL/min); 3 patients had no or minimal graft flow. Redoing the graft anastomosis in these 3 patients resulted in normalization of graft flow. The mean flow increased significantly after correction from 0.5 +/- 0.7 mL/min to 15.7 +/- 9.6 mL/min (p < 0.02). Conversely, vascular resistance decreased significantly from 138 +/- 10 to 4.8 +/- 1.8 Ohmv (p < 0.0001), as did the pulsatility index (from 146.9 +/- 95.7 to 3.4 +/- 1.8; p < 0.001). After correction, coronary flow reserve was 2.5 +/- 1.1. CONCLUSIONS: Measurements of intraoperative flow and resistance as well as derived variables allow assessment of early graft function and thus help prevent graft failure and reduce perioperative infarction. Transit-time volume flow might be a simple tool for quality control in coronary bypass procedures.


Asunto(s)
Hemorreología , Anastomosis Interna Mamario-Coronaria , Grado de Desobstrucción Vascular , Anastomosis Quirúrgica , Humanos , Flujo Pulsátil , Insuficiencia del Tratamiento , Resistencia Vascular
13.
Eur J Cardiothorac Surg ; 10(12): 1064-8; discussion 1069-70, 1996.
Artículo en Inglés | MEDLINE | ID: mdl-10369641

RESUMEN

OBJECTS: Myocardial revascularization is performed preferentially with internal mammary artery grafts. Pedicle preparation and pharmacologic vasodilatory treatment vary greatly. Objective measurements are difficult since peripheral and later coronary vascular resistance and possible competitive flow of the native bypassed coronary artery will influence the results significantly. Our objectives were: (1) measurement of internal mammary artery graft flow with the transit-time flow technique; (2) comparison of two surgical take-down techniques (skeletonizing vs standard pedicle preparation); (3) quantitation of transit-time flow compared to the free pedicle flow and (4) the vasodilatory effect of papaverine on internal mammary artery flow. METHOD: Consecutive elective cases of coronary artery bypass grafting, performed by two surgeons using routinely either skeletonizing of the internal mammary artery (group A, n = 10) or classical pedicle preparation technique (group B, n = 10), were studied prospectively. Anesthesia, cardiopulmonary bypass and operative data were otherwise comparable; likewise, hemodynamic parameters showed no statistical differences between the two groups. Transit-time flow (CardioMed, Medi-Stim, Norway) was measured at the following time points: beginning (1) and end of take-down (2); after papaverine soaking: before (3) and on cardiopulmonary bypass (4); free flow into a beaker (5); after anastomosis; on (6) and off cardiopulmonary bypass (7). RESULTS: Measurement of mean flow showed the following results: (1) severe vasoconstruction of the internal mammary artery was detected in both groups regardless of the preparation technique (occurring earlier in group A); (2) papaverine soaking caused a moderate flow increase (up to 40%); (3) with corresponding cardiopulmonary bypass flow (4.4 vs. 4.1 l/min in group B) a higher free flow in group A was evident (67.7 vs. 50.7 ml/min); (4) after coronary grafting, transit-time flow showed no significant differences between the two groups and (5) using a 3 mm probe, a linear correlation was demonstrated between transit-time flow and simultaneously measured free flow (r = 0.89). CONCLUSION: Intraoperative transit-time flow measurement is a reliable method for assessing internal mammary artery and coronary artery bypass flow; considering the simple technical application, the procedure may be regarded as a valuable instrument of quality control.


Asunto(s)
Puente de Arteria Coronaria , Circulación Coronaria/fisiología , Electrofisiología/métodos , Arterias Mamarias/fisiología , Monitoreo Intraoperatorio/métodos , Velocidad del Flujo Sanguíneo , Femenino , Humanos , Masculino , Arterias Mamarias/efectos de los fármacos , Arterias Mamarias/trasplante , Papaverina , Estudios Prospectivos , Reproducibilidad de los Resultados , Vasodilatación/efectos de los fármacos , Vasodilatadores
14.
Eur J Cardiothorac Surg ; 14 Suppl 1: S76-81, 1998 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9814798

RESUMEN

OBJECTIVES: To assess intraoperative flow of arterial and venous coronary grafts after myocardial revascularization which may allow early detection of low flow situations, especially during minimally invasive coronary bypass surgery (MIDCAB), and lead to immediate correction of technical problems. METHODS: In two patients with severe and diffuse multi-vessel disease the left internal mammary artery (IMA) was connected to the left anterior descending artery (LAD). During reperfusion, the flow was measured in the IMA and vein grafts using a transit time flow meter. RESULTS: In both cases the IMA showed only a systolic pendulating flow curve with a mean flow of 0-1 ml/min and a high resistance. Manual IMA assessment revealed an adequate pulsation. Both distal IMA anastomoses were re-explored on cardiopulmonary bypass yielding an initial flow of 7 and 14 ml/min, respectively. After treatment with papaverine/adenosine the IMA flow increased from 7 to 26 ml/min (coronary flow reserve (CFR) = 3.7) and from 14 to 46 ml/min (CFR = 3.3), respectively. CONCLUSION: Intraoperative flow assessment of IMA and venous bypass grafts can be recommended to monitor flow; especially during MIDCAB procedures.


Asunto(s)
Circulación Coronaria/fisiología , Enfermedad Coronaria/cirugía , Anastomosis Interna Mamario-Coronaria , Anciano , Velocidad del Flujo Sanguíneo/efectos de los fármacos , Velocidad del Flujo Sanguíneo/fisiología , Circulación Coronaria/efectos de los fármacos , Enfermedad Coronaria/fisiopatología , Epinefrina/farmacología , Circulación Extracorporea , Femenino , Humanos , Cuidados Intraoperatorios , Complicaciones Intraoperatorias/diagnóstico , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos , Papaverina/farmacología , Insuficiencia del Tratamiento
15.
Eur J Cardiothorac Surg ; 15(4): 496-500; discussion 500-1, 1999 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-10371128

RESUMEN

OBJECTIVE: To compare three different techniques of distal aortic repair in acute type A (de Bakey type I) aortic dissection and to evaluate their impact on the late morphology of the aortic arch and descending aorta and on the incidence of reoperation. METHODS: From 65 patients operated on due to an acute type A aortic dissection between 1989 and 1993, 54 long-term survivors underwent clinical and radiologic follow-up examination after a mean postoperative interval of 62+/-16 months. The surgical techniques of distal aortic reconstruction included closed repair using Teflon felt reinforcement under moderate hypothermic cardiopulmonary bypass (n = 20) and open repair in deep hypothermic circulatory arrest using either Teflon felt reinforcement (n = 16) or gelatin-resorcin-formaldehyde (GRF) glue (n = 18) to readapt the dissected aortic layers. In all patients, MR imaging was performed on a 1.5-T whole body imaging system for the evaluation of the morphology and function of the heart, aorta and supraaortic branches. RESULTS: Overall hospital mortality following surgical repair of type A aortic dissection was 15.4% during this time period. The highest rate of persistent false lumen perfusion (17/20, 85%) and presence of an intimal flap in the aortic arch (13/20, 65%) was observed in patients following closed repair of acute ascending aortic dissection, whereas the lowest rate of such findings was demonstrated in patients who had undergone open distal aortic repair using biological glue (false lumen perfusion 10/18, 55% and intimal flap in the arch 2/18, 11%). Redo-surgery was significantly reduced in the open repair group using GRF glue (1/18, 5.5%) as compared with the Teflon felt repair group (3/16, 18%) and the closed repair group (6/20, 30%). CONCLUSIONS: In patients with acute type A dissection, open distal aortic repair using GRF-glue favourably influences both (1) the severity of late morphologic alterations in the downstream aorta and (2) the incidence of reoperation.


Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Aorta Torácica/patología , Procedimientos Quirúrgicos Cardíacos/métodos , Puente Cardiopulmonar , Combinación de Medicamentos , Formaldehído/uso terapéutico , Gelatina/uso terapéutico , Humanos , Hipotermia Inducida , Imagen por Resonancia Magnética , Politetrafluoroetileno/uso terapéutico , Reoperación , Resorcinoles/uso terapéutico , Estudios Retrospectivos , Adhesivos Tisulares/uso terapéutico , Resultado del Tratamiento
16.
Eur J Cardiothorac Surg ; 4(7): 390-3, 1990.
Artículo en Inglés | MEDLINE | ID: mdl-2397132

RESUMEN

Sixteen patients (age 13-53 years) with accidental deep hypothermia have been rewarmed in our clinic during the last 10 years, 14 by femoro-femoral cardiopulmonary bypass (CPB) of whom 11 had a cardiopulmonary arrest (asystole in 5 and ventricular fibrillation in 6). On admission, the latter were clinically dead showing wide non-reactive pupils and being supported by ventilation and external heart massage. In the survivors, the mean length of cold exposure was 4.4 h (2-5.5 h) and mean arrest interval until initiation of CPB was 2.5 h (1.4-3.7 h). Rectal temperature on admission ranged from 17.5 degrees C to 26 degrees C (mean 22.5 degrees C). The causes for hypothermia were fall into a crevasse (5), avalanche (1), drowning (2) and cold exposure (3) including 2 suicide attempts. Results are summarized in the following table: [table: see text] Eight of the 11 patients with deep hypothermia and cardiac arrest were rewarmed and resuscitated successfully with CPB. Three patients, including 2 cases of asphyxia (avalanche and drowning), could not be weaned from CPB despite adequate rewarming. The other drowned patient (53 years) died on the 3rd postoperative day (POD) from ARDS. The main complication was pulmonary edema (57%) and transient neurological deficits. All survivors became conscious during the first POD and resumed, their professional activity. We conclude that patients with accidental deep hypothermia and even prolonged cardiopulmonary arrest should be rewarmed and resuscitated rapidly by cardiopulmonary bypass. These measures are very promising particularly if the cause of accident and the circumstances suggest that cardiopulmonary arrest was induced by hypothermia alone without other asphyxiating mechanisms.


Asunto(s)
Puente Cardiopulmonar/métodos , Paro Cardíaco/terapia , Calor/uso terapéutico , Hipotermia/terapia , Resucitación/métodos , Adolescente , Adulto , Puente Cardiopulmonar/normas , Causas de Muerte , Femenino , Paro Cardíaco/etiología , Paro Cardíaco/mortalidad , Humanos , Hipotermia/etiología , Hipotermia/mortalidad , Masculino , Persona de Mediana Edad , Resucitación/normas , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia
17.
Eur J Cardiothorac Surg ; 15(6): 795-802, 1999 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10431861

RESUMEN

OBJECTIVES: After coronary artery bypass surgery, patency and flow assessment is based on invasive methods such as angiography and intravascular ultrasound or flow wire techniques. The aim of the study was to compare intraoperative transit time flow measurements of coronary bypass grafts with early postoperative color-Doppler and MR-imaging assessment. METHODS: In 22 patients (62+/-8.5 years) undergoing elective coronary bypass surgery the flow was measured in all internal mammary artery grafts (IMA) and saphenous vein grafts using the transit time flow technique. Postoperatively (days 5-7) all patients had a color-Doppler IMA graft assessment followed by a MR-angiography and flow measurement (navigator echo phase contrast technique with and without contrast bolus application) to determine patency and graft flow. RESULTS: Data are expressed as the mean +/- SD). (1) In all patients the left IMA graft to the left anterior descending coronary artery (LAD) could be identified and flow could be assessed with both color-Doppler and MRI. Venous grafts could only be visualized by MRI. The use of an intravenous contrast bolus enhanced the visualization of coronary artery bypass grafts. (2) The mean IMA to LAD flow was 33+/-17 ml/min intraoperatively by transit time and postoperatively 36+/-25 ml/min by MR respectively 66+/-54 ml/min by color-Doppler technique. (3) The systolic/diastolic flow ratio was 0.44+/-0.12 intraoperatively and 0.43+/-0.17 postoperatively by MR respectively 0.67+/-1.0 by color-Doppler. (4) A statistically significant correlation could be demonstrated between intraoperative transit time and postoperative MR flow measurements (r = 0.57; P < 0.04), whereas the correlations to color-Doppler flow were poor. Postoperatively MR and color-Doppler showed a good correlation of systolic/diastolic flow ratio (r = 0.88; P < 0.008). CONCLUSIONS: The color-Doppler method during echocardiography and MR-imaging are useful non-invasive techniques to visualize postoperative IMA grafts for patency assessment. The quantification of IMA flow is still difficult with either technique, but MR flow measurements showed the best correlation to the intraoperatively measured transit time flow. The MR technique is the most promising non-invasive method for postoperative evaluation of coronary bypass grafts, since it allows visualization and reliable flow quantification.


Asunto(s)
Puente de Arteria Coronaria , Circulación Coronaria , Angiografía por Resonancia Magnética , Ultrasonografía Doppler en Color , Velocidad del Flujo Sanguíneo , Medios de Contraste , Humanos , Periodo Intraoperatorio , Masculino , Arterias Mamarias/diagnóstico por imagen , Arterias Mamarias/fisiología , Arterias Mamarias/trasplante , Persona de Mediana Edad , Vena Safena/diagnóstico por imagen , Vena Safena/fisiología , Vena Safena/trasplante
18.
Eur J Cardiothorac Surg ; 14(4): 426-30, 1998 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9845150

RESUMEN

BACKGROUND: Detection of cardiac rejection is a major problem in cardiac transplantation. The gold standard is, and remains, endomyocardial biopsy. PURPOSE: Evaluation of MR-imaging and MR-spectroscopy for detection of cardiac rejection. METHODS: Orthotopic cardiac transplantation (HTX) was performed in 13 pigs (body weight 30 kg). All animals obtained immunosuppressive (triple) therapy for 1 week after the operation. Thereafter immunosuppression was stopped to induce cardiac rejection. MRI and MRS (1.5 Tesla General Electrics Signa) were performed pre- and post-operatively on days 10, 17, 24 and 31. The degree of rejection was determined post-operatively using endomyocardial biopsy (Texas grading score). RESULTS: (1) MR-imaging: LV function remained unchanged after HTX. LV mass increased (+42%; P < 0.05) with cardiac rejection. (2) MR-spectroscopy: a marked reduction in the ratio of phosphocreatine and adenosine triphosphate, respectively, to inorganic phosphate was observed in the rejecting hearts. (3) Histologic grading confirmed cardiac rejection after stopping immunosuppression. The Texas score was 5.7+/-0.8 at autopsy. CONCLUSIONS: MR-imaging and MR-spectroscopy allow the detection of changes associated with cardiac rejection. Both techniques are correlated with histologic rejection. However, endomyocardial biopsy remains the gold standard for reliable detection of cardiac rejection.


Asunto(s)
Rechazo de Injerto/diagnóstico , Trasplante de Corazón , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Adenosina Trifosfato/análisis , Animales , Biopsia , Rechazo de Injerto/metabolismo , Rechazo de Injerto/patología , Rechazo de Injerto/fisiopatología , Tabiques Cardíacos/patología , Trasplante de Corazón/patología , Ventrículos Cardíacos/patología , Inmunosupresores/uso terapéutico , Miocardio/química , Miocardio/patología , Fosfatos/análisis , Fosfocreatina/análisis , Reproducibilidad de los Resultados , Volumen Sistólico/fisiología , Porcinos , Función Ventricular Izquierda/fisiología
19.
Eur J Cardiothorac Surg ; 19(4): 487-92, 2001 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11306318

RESUMEN

OBJECTIVE: Immunosuppressive agents have been proposed to reduce neointimal hyperplasia in synthetic vascular grafts. Thus, the purpose of the present study was to evaluate the safety and efficacy of rapamycins (systemic vs. local vs. oral administration) and mycophenolate mofetil (MMF) to reduce intimal hyperplasia in infrarenal synthetic vascular grafts of the rat. METHODS: Fifty-four Wistar rats (250 g) completed the study after a synthetic vascular graft (ePTFE, Gore-tex, 2 mm diameter, 10 mm length) was implanted end-to-end in the infrarenal aorta. The animals were divided into three groups: group 1 consisted of 12 control animals, group 2 consisted of 37 rats receiving rapamycins, either per os (RAD, 1.5 or 3 mg/kg), intraperitoneally (RPM, 1.5 or 3 mg/kg) or locally (RPM soaking of the graft); and in group 3 (n=5), MMF (40 mg/kg) was administered orally. The animals were followed weekly with weight controls and signs of toxicity for 30 (n=37) and 60 (n=17) days, respectively. All animals were sacrificed and underwent histological examination at completion of the study. RESULTS: All animals survived in groups 1 and 3, but five died in group 2. The weight gain was normal in all groups, except for the subgroup 2a receiving high dose rapamycins orally. All rats in group 3 suffered from diarrhea, whereas animals receiving high dose rapamycins showed toxic signs (hair loss, wound healing problems). Histological examination showed a significant increase in intimal hyperplasia in group 1 (0.03+/-0.01 and 0.14+/-0.05 microm after 30 and 60 days, respectively; P<0.01). Rapamycins in either application or dosage had no significant effect on intimal hyperplasia. CONCLUSIONS: Local or systemic administration of rapamycins has no effect on intimal hyperplasia in synthetic vascular grafts. In contrast, toxic signs with weight loss were observed in animals treated with high dose rapamycins, but not in those treated with MMF. Thus, in the rat model, immunosuppression with rapamycins or MMF cannot be recommended for the prevention of intimal hyperplasia in the synthetic vascular graft model.


Asunto(s)
Prótesis Vascular , Inmunosupresores/farmacología , Ácido Micofenólico/farmacología , Sirolimus/farmacología , Túnica Íntima/patología , Anastomosis Quirúrgica , Animales , Hiperplasia , Modelos Animales , Ácido Micofenólico/análogos & derivados , Politetrafluoroetileno , Ratas , Ratas Wistar , Grado de Desobstrucción Vascular
20.
Int J Artif Organs ; 22(4): 210-6, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10466952

RESUMEN

BACKGROUND: The aim of this prospective study was to compare the effect of autologous unprocessed to processed residual cardiopulmonary bypass blood (CPB) on patients' laboratory and clinical parameters and outcome. METHODS: 20 patients undergoing elective coronary artery bypass surgery were randomized to receive either unprocessed CPB blood (control group) or processed CPB blood employing the Continuous AutoTransfusion System (CATS; Fresenius, Bad Homburg, Germany). We have shown that this method eliminated >93% of activated mediators. Serial laboratory parameters including complement activation, coagulation factors and the stimulation of IL-6 and IL-8 were compared with clinical side effects and patients' outcome. RESULTS: Compared to control patients, retransfusion of unprocessed CBP blood significantly increased heparin, free plasma hemoglobin and D-Dimers. Postoperatively, three patients in the control group and two patients in the CATS group required prolonged mechanical ventilation or developed infections associated respectively with elevated C3a (desArg) or IL-6 concentration. CONCLUSIONS: CATS-processing of CPB blood provided a high-quality red blood cell concentrate, resulting in a reduced load of retransfused activated mediators.


Asunto(s)
Transfusión de Sangre Autóloga/métodos , Puente Cardiopulmonar/métodos , Factores de Coagulación Sanguínea/análisis , Activación de Complemento , Complemento C3a/análisis , Puente de Arteria Coronaria , Procedimientos Quirúrgicos Electivos , Femenino , Hemoglobinas/análisis , Heparina/sangre , Humanos , Infecciones/etiología , Interleucina-6/sangre , Interleucina-8/sangre , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Prospectivos , Respiración Artificial
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA