RESUMEN
The current study aimed to investigate the relationship between body parameters and the current-time product (mAs) in chest digital radiography using a non-contact infrared thickness-measurement sensor. An anthropomorphic chest phantom was first used to understand variations in mAs over multiple positionings during chest radiography when using the automatic exposure control (AEC) technique. In a human study, 929 consecutive male subjects who underwent regular chest examinations were enrolled, and their height (H), weight (W), and body mass index (BMI) were recorded. In addition, their chest thickness (T) was measured at exhalation using a non-contact infrared sensor, and chest radiography was then performed using the AEC technique. Finally, the relationship between four body parameters (T, BMI, T*BMI, and W/H) and mAs was investigated by fitting the body parameters to mAs using three curve models. The phantom study showed that the maximum mAs was 1.76 times higher than the lowest mAs during multiple positionings in chest radiography. In the human study, all chest radiographs passed the routine quality control procedure and had an exposure index between 100 and 212. In curve fitting, the comparisons showed that W/H had a closer relationship with mAs than the other body parameters, while the first-order power model with W/H fitted to mAs performed the best and had an R-square of 0.9971. We concluded that the relationship between W/H and mAs in the first-order power model may be helpful in predicting the optimal mAs and reducing the radiation dose for chest radiography when using the AEC technique.
Asunto(s)
Intensificación de Imagen Radiográfica , Tórax , Masculino , Humanos , Radiografía , Tórax/diagnóstico por imagen , Índice de Masa Corporal , EspiraciónRESUMEN
PURPOSE: To assess the use of the dual-energy computed tomographic (CT) virtual noncalcium technique in the evaluation of bone marrow edema in vertebral compression fractures. MATERIALS AND METHODS: This prospective study was approved by the institutional review board; informed consent was obtained from all patients. Sixty-three consecutive patients with 112 thoracic and/or lumbar vertebral compression fractures were studied between January 2011 and April 2012. All patients underwent both dual-energy CT (100 kV and Sn140 kV, where Sn indicates the use of a 0.4-mm tin filter) and magnetic resonance (MR) imaging. Dual-energy CT data were postprocessed by using a three-material decomposition algorithm for generating noncalcium images of the collapsed bodies. Two radiologists evaluated for the presence of abnormal attenuation alterations in the bone marrow by using color-coded maps and measured CT numbers on noncalcium grayscale images. Bone sclerosis and intravertebral air were evaluated with CT scans. MR images served as the reference standard. CT numbers were subjected to receiver operating characteristic curve analysis. RESULTS: MR imaging depicted 46 edematous and 66 nonedematous vertebral compression fractures. Eighty-two bodies were classified as having less than 50% sclerosis and/or air. Significant differences in noncalcium CT numbers between edematous and nonedematous vertebral compression fractures were found for both readers (P < .0001). CT numbers for the diagnosis of bone marrow edema on the basis of MR imaging revealed areas under the receiver operating characteristic curve of 0.799 and 0.841 for readers 1 and 2, respectively (P = .56). Use of a cutoff value of -80 to differentiate edematous vertebral bodies resulted in a sensitivity of 96.3%, specificity of 98.2%, and accuracy of 97.6% in the group of vertebral bodies with less than 50% sclerosis and/or air. CONCLUSION: Dual-energy CT virtual noncalcium images were able to depict bone marrow in the collapsed vertebral bodies, especially in those with less than 50% sclerosis and/or air.
Asunto(s)
Médula Ósea/patología , Edema/diagnóstico por imagen , Fracturas por Compresión/diagnóstico por imagen , Fracturas de la Columna Vertebral/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios ProspectivosRESUMEN
Key Clinical Message: Temporal percutaneous transhepatic duodenum drainage (PTDD) seems to be effective in the treatment of postoperative afferent loop syndrome (ALS) following transverse loop colostomy for obstructive colorectal cancer. Abstract: Management of obstructive colorectal cancer still remains a challenge. There are various options with different risks of mortality and mobility for obstructive colorectal cancer. A rare unexpected postoperative ALS following a low anterior resection and transverse loop colostomy for obstructive colorectal cancer is presented in this report. A 64-year-old man had the acute ALS had been noted 10 days after transverse loop colostomy. An option was temporal PTDD treatment in the patient with history of Billroth's operation II for upper gastrointestinal bleeding 30 years ago. Acute ALS was treated by temporal PTDD. The drainage tube for PTDD was not removed until closure of the transverse colostomy 2 months later. The patient recovered uneventfully. Acute ALS after transverse loop colostomy for obstructive colorectal cancer is rare and has never been reported in the literature. The mechanism of acute ALS after construction of a loop colostomy and the treatment strategy of PTDD for acute ALS is presented.