Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Braz J Cardiovasc Surg ; 32(6): 492-497, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29267612

RESUMEN

INTRODUCTION: Chronic stimulation of the right ventricle with pacemaker is associated with ventricular dyssynchrony and loss of contractility, even in subjects without previous dysfunction. In these patients, there is a debate of which pacing site is less associated with loss of ventricular function. OBJECTIVE: To compare pacemaker-induced dyssynchrony among different pacing sites in right ventricular stimulation. METHODS: Cross-sectional study of outpatients with right ventricle stimulation higher than 80% and preserved left ventricular ejection fraction. Pacing lead position (apical, medial septum or free wall) was assessed through chest X-rays. Every patient underwent echocardiogram to evaluate for dyssynchrony according to CARE-HF criteria: aortic pre-ejection time, interventricular delay and septum/posterior wall delay on M mode. RESULTS: Forty patients were included. Fifty-two percent had apical electrode position, 42% mid septum and 6% free wall. Mean QRS time 148.97±15.52 milliseconds. A weak correlation between the mean QRS width and pre-aortic ejection time (r=0.32; P=0.04) was found. No difference in QRS width among the positions could be noted. Intraventricular delay was lower in apical patients against mid septal (34.4±17.2 vs. 54.3±19.1 P<0.05) - no difference with those electrode on the free wall. No difference was noted in the pre-aortic ejection time (P=0.9). CONCLUSION: Apical pacing showed a lower interventricular conduction delay when compared to medial septum site. Our findings suggest that apical pacing dyssynchrony is not ubiquitous, as previously thought, and that it should remain an option for lead placement.


Asunto(s)
Estimulación Cardíaca Artificial/efectos adversos , Marcapaso Artificial/efectos adversos , Disfunción Ventricular Derecha/etiología , Anciano , Arritmias Cardíacas/fisiopatología , Estimulación Cardíaca Artificial/métodos , Estudios Transversales , Ecocardiografía , Electrocardiografía , Femenino , Ventrículos Cardíacos , Humanos , Masculino , Contracción Miocárdica , Volumen Sistólico , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular Derecha
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA