RESUMEN
BACKGROUND: Preoperative fasting reduces the risk of pulmonary aspiration during anaesthesia, and 2-h fasting for clear fluids has commonly been recommended. Based on recent evidence of shorter fasting times being safe, the Swiss Society of Paediatric Anaesthesia began recommending 1-h fasting for clear fluids in 2018. This prospective, observational, multi-institutional cohort study aimed to investigate the incidence of adverse respiratory events after implementing the new national recommendation. METHODS: Eleven Swiss anaesthesia institutions joined this cohort study and included patients aged 0-15 yr undergoing anaesthesia for elective procedures after implementation of the 1-h fasting instruction. The primary outcome was the perioperative (defined as the time from anaesthesia induction to emergence) incidence of pulmonary aspiration, gastric regurgitation, and vomiting. Data are presented as median (inter-quartile range; minimum-maximum) or count (percentage). RESULTS: From June 2019 to July 2021, 22 766 anaesthetics were recorded with pulmonary aspiration occurring in 25 (0.11%), gastric regurgitation in 34 (0.15%), and vomiting in 85 (0.37%) cases. No major morbidity or mortality was associated with pulmonary aspiration. Subgroup analysis by effective fasting times (<2 h [n=7306] vs ≥2 h [n=14 660]) showed no significant difference for pulmonary aspiration between these two groups (9 [0.12%] vs 16 [0.11%], P=0.678). Median effective fasting time for clear fluids was 157 [104-314; 2-2385] min. CONCLUSIONS: Implementing a national recommendation of 1-h clear fluid fasting was not associated with a higher incidence of pulmonary aspiration compared with previously reported data.
Asunto(s)
Reflujo Laringofaríngeo , Neumonía por Aspiración , Niño , Humanos , Incidencia , Estudios de Cohortes , Estudios Prospectivos , Ayuno , Cuidados Preoperatorios/métodos , Aspiración Respiratoria , VómitosRESUMEN
Start-up delays of syringe pump assemblies can impede the timely commencement of an effective drug therapy when using microinfusions in hemodynamically unstable patients. The application of the venting principle has been proposed to eliminate start-up delays in syringe pump assemblies. However, effectively delivered infusion volumes using this strategy have so far not been measured. This invitro study used two experimental setups to measure the effect of the venting principle compared to a standard non-venting approach on delivered start-up infusion volumes at various timepoints, backflow volumes, flow inversion and zero drug delivery times by means of liquid flow measurements at flow rates of 0.5, 1.0 and 2.0 mL/h. Measured delivered initial start-up volumes were negative with all flow rates in the vented and non-vented setup. Maximum backflow volumes were 1.8 [95% CI 1.6 to 2.3] times larger in the vented setup compared to the non-vented setup (p < 0.0001). Conversely, times until flow inversion were 1.5 [95% CI 1.1 to 2.9] times shorter in the vented setup (p < 0.002). This led to comparable zero drug delivery times between the two setups (p = 0.294). Start-up times as defined by the achievement of at least 90% of steady state flow rate were achieved faster with the vented setup (p < 0.0001), but this was counteracted by the increased backflow volumes. The application of the venting principle to the start-up of microinfusions does not improve the timely delivery of drugs to the patient since the faster start-up times are counteracted by higher backflow volumes when opening the three-way stopcock.
Asunto(s)
Sistemas de Liberación de Medicamentos , Bombas de Infusión , Humanos , Infusiones Intravenosas , Diseño de EquipoRESUMEN
PURPOSE: Vertical displacement of infusion pumps used in patient-controlled analgesia can cause irregularities in drug delivery and is especially crucial at low flow rates, which are commonly used in pediatrics. There is only scarce data available regarding the extent of these inaccuracies. The current in vitro study therefore aimed at a comparison of the performance of two commonly used PCA pumps at different pole positions due to vertical displacement. METHODS: The Syramed® µSP6000 Chroma syringe infusion pump featuring a stepper motor drive was compared to the CADD®-Solis pump utilizing a linear peristaltic pump system at two different flow rates (0.3 ml/h and 1 ml/h) and three different levels of height (0, + 50 and - 50 cm). Flow patterns and delivered volumes were measured after every change in position and infusion boluses, retrograde aspiration volumes and zero-drug delivery time were calculated. RESULTS: The Syramed® pump was more susceptible to vertical displacement than the CADD®-Solis pump and showed overall greater inaccuracies in the delivered volumes as well as higher infusion boluses, retrograde aspiration volumes and zero-drug delivery time at both flow rates. CONCLUSION: The observed differences between the pumps might be explained by the higher compliance of this syringe pump and the diverse working mechanisms. Overall, the CADD®-Solis pump might be considered a preferable option for patient-controlled analgesia in children. It is nonetheless essential for medical staff to be aware of the effects of vertical displacement of PCA pumps and to minimize these displacements as much as possible.
RESUMEN
The purpose of this in vitro study was to evaluate the impact of the vertical level of the stopcock connecting the infusion line to the central venous catheter on start-up fluid delivery in microinfusions. Start-up fluid delivery was measured under standardized conditions with the syringe outlet and liquid flow sensors positioned at heart level (0 cm) and exposed to a simulated CVP of 10 mmHg at a set flow rate of 1 ml/h. Flow and intraluminal pressures were measured with the infusion line connected to the stopcock primarily placed at vertical levels of 0 cm, + 30 cm and - 30 cm or primarily placed at 0 cm and secondarily, after connecting the infusion line, displaced to + 30 cm and - 30 cm. Start-up fluid delivery 10 s after opening the stopcock placed at zero level and after opening the stopcock primarily connected at zero level and secondary displaced to vertical levels of + 30 cm and - 30 cm were similar (- 10.52 [- 13.85 to - 7.19] µL; - 8.84 [- 12.34 to - 5.33] µL and - 11.19 [- 13.71 to - 8.67] µL (p = 0.469)). Fluid delivered at 360 s related to 65% (zero level), 71% (+ 30 cm) and 67% (- 30 cm) of calculated infusion volume (p = 0.395). Start-up fluid delivery with the stopcock primarily placed at + 30 cm and - 30 cm resulted in large anterograde and retrograde fluid volumes of 34.39 [33.43 to 35.34] µL and - 24.90 [- 27.79 to - 22.01] µL at 10 s, respectively (p < 0.0001). Fluid delivered with the stopcock primarily placed at + 30 cm and - 30 cm resulted in 140% and 35% of calculated volume at 360 s, respectively (p < 0.0001). Syringe infusion pumps should ideally be connected to the stopcock positioned at heart level in order to minimize the amounts of anterograde and retrograde fluid volumes after opening of the stopcock.
Asunto(s)
Diseño de Equipo , Bombas de Infusión , Jeringas , Humanos , Infusiones Intravenosas/instrumentación , Catéteres Venosos Centrales , Cateterismo Venoso Central/instrumentación , Cateterismo Venoso Central/métodos , Presión Venosa Central , PresiónRESUMEN
Microinfusions are commonly used for the administration of catecholamines, but start-up delays pose a problem for reliable and timely drug delivery. Recent findings show that venting of the syringe infusion pump with draining of fluid to ambient pressure before directing the flow towards the central venous catheter does not counteract start-up delays. With the aim to reduce start-up delays, this study compared fluid delivery during start-up of syringe infusion pumps without venting, with ambient pressure venting, and with central venous pressure (CVP)-adjusted venting. Start-up fluid delivery from syringe pumps using a microinfusion of 1 mL/h was assessed by means of liquid flow measurement at 10, 60, 180 and 360 s after opening the stopcock and starting the pump. Assessments were performed using no venting, ambient pressure venting or CVP-adjusted venting, with the pump placed either at zero, - 43 cm or + 43 cm level and exposed to a simulated CVP of 10 mmHg. Measured fluid delivery was closest to the calculated fluid delivery for CVP-adjusted venting (87% to 100% at the different timepoints). The largest deviations were found for ambient pressure venting (- 1151% to + 82%). At 360 s after start-up 72% to 92% of expected fluid volumes were delivered without venting, 46% to 82% with ambient pressure venting and 96% to 99% with CVP-adjusted venting. CVP-adjusted venting demonstrated consistent results across vertical pump placements (p = 0.485), whereas the other methods had significant variances (p < 0.001 for both). In conclusion, CVP-adjusted venting effectively eliminates imprecise drug delivery and start-up delays when using microinfusions.
Asunto(s)
Catéteres Venosos Centrales , Bombas de Infusión , Humanos , Diseño de Equipo , Catecolaminas , Sistemas de Liberación de MedicamentosRESUMEN
BACKGROUND: Connection and opening a syringe infusion pump to a central venous line can lead to acute anterograde or retrograde fluid shifts depending on the level of central venous pressure. This may lead to bolus events or to prolonged lag times of intravenous drug delivery, being particularly relevant when administering vasoactive or inotropic drugs in critically ill patients using microinfusion. The aim of this study was to assess the effect of syringe pump positioning at different vertical heights on start-up fluid delivery before versus after purging and connection the pump to the central venous catheter. METHODS: This in vitro study measured ante- and retrograde infusion volumes delivered to the central venous line after starting the syringe pump at a set infusion rate of 1 mL/h. In setup one, the pump was first positioned to vertical levels of +43 cm or -43 cm and then purged and connected to a central venous catheter. In setup two, the pump was first purged and connected at zero level and secondarily positioned to a vertical level of +43 cm or -43 cm. Central venous pressure was adjusted to 10 mmHg in both setups. RESULTS: Positioning of the pump prior to purging and connection to the central venous catheter resulted in a better start-up performance with delivered fluid closer to programmed and expected infusion volumes when compared to the pump first purged, connected, and then positioned. Significant backflow volumes were observed with the pump purged and connected first and then positioned below zero level. No backflow was measured with the pump positioned first below zero level and then purged and connected. CONCLUSIONS: Syringe infusion pump assemblies should be positioned prior to purging and connection to a central venous catheter line when starting a new drug, particularly when administering highly concentrated vasoactive or inotropic drugs delivered at low flow rates.
Asunto(s)
Catéteres Venosos Centrales , Bombas de Infusión , Humanos , Jeringas , Enfermedad Crítica , Infusiones IntravenosasRESUMEN
BACKGROUND: Intravenous administration of highly concentrated and potent drugs at low flow rates is common practice, particularly in critically ill children. Drug delivery during infusion start-up can be considerably delayed by intrinsic factors of syringe infusion pump assemblies. The impact of central venous pressures on the course of start-up fluid delivery of such microinfusions remains unknown. METHODS: Infusion volumes delivered after activation of the start button in a conventional 50 mL syringe infusion pump assembly equilibrated (representing classical in vitro testing) and not equilibrated (representing real clinical conditions) to central venous pressure levels of 0, 10 and 20 mmHg at a set infusion flow rate of 1 mL/h were measured using a fluidic flow sensor. RESULTS: The experimental setup mimicking real life conditions demonstrated considerable differences in fluid delivery during pump start-up depending on central venous pressure. A central venous pressure of 0 mmHg resulted in massive fluid delivery at infusion start-up, while central venous pressure levels of 10 and 20 mmHg resulted in retrograde flows with related mean (95% CI) zero-drug delivery times of 3.22 (2.98-3.46) min and 4.51 (4.33-4.69) min, respectively (p < .0001). CONCLUSION: Depending on central venous pressure level, connection and starting a new syringe pump can result in significant antegrade or retrograde fluid volumes. In clinical practice, this can lead to hemodynamic instability and hence requires clinical alertness. Further research and methods to improve start-up performance in syringe infusion pump systems are desirable.
Asunto(s)
Bombas de Infusión , Niño , Humanos , Presión Venosa Central , Preparaciones Farmacéuticas , Infusiones IntravenosasRESUMEN
PURPOSE OF REVIEW: In 1989, the United Nations passed the 'Convention on the Rights of the Child' (UNCRC) and, among others claimed the highest attainable standard of health for children and consequently the highest level of safety and quality in paediatric anaesthesia. SAFETOTS (Safe Anesthesia For Every Tot, www.safetots.org ), an initiative of international active paediatric anaesthetists, has derived 10 rights, the '10 R' of children undergoing anaesthesia care, which are critical for the well being of the child. RECENT FINDINGS: The current situation in paediatric anaesthesia care in Europe does not always meet the requirements demanded by the UNCRC. Anaesthesia-related complications in children are still persistent. Anaesthesiologists are frequently asked to provide care for newborns, infants and small children without having sufficient child-specific expertise, resulting in an increased morbidity and mortality. SUMMARY: This article will explain these statutes of children's rights and their implications for everyday paediatric anaesthesia. Furthermore, it will also express the institutional and political changes that are needed to guarantee children their right to enjoy the highest attainable standard of health.
Asunto(s)
Anestesia , Naciones Unidas , Lactante , Niño , Recién Nacido , Humanos , Anestesia/efectos adversos , Europa (Continente)RESUMEN
BACKGROUND: There is a paucity of evidence regarding the optimal type of tracheal tube to be advanced over a Frova catheter when performing a 'bougie' emergency front-of-neck airway (eFONA) technique in infants during a 'cannot intubate, cannot oxygenate' situation. METHODS: A prospective non-inferiority trial in a rabbit cadaver surgical tracheotomy model to assess the performance of the eFONA technique with an uncuffed 3.5 mm ID tracheal tube vs a cuffed 3.0 mm ID tracheal tube. Queried outcomes include success rate, performance time, and severe secondary airway injuries among tracheal tube types. RESULTS: In 60 tracheostomies performed by 30 participants, the overall success rate was 98%. Performance time was independent from tracheal tube choice (uncuffed: 61 s [95% confidence interval (CI), 52-76], cuffed: 64 s [95% CI, 55-79]; P = 0.82). No tracheal tube type was preferred in terms of usability by participants. The cuffed tracheal tube required increased force to be advanced over the Frova catheter and was associated with a risk ratio of 2.5 (95% CI, 0.53-11.9; number needed to harm, 10) for severe secondary airway injuries when compared with the uncuffed tracheal tube. CONCLUSION: In performing eFONA in the rabbit cadaver model, an ID 3.5 uncuffed is non-inferior to an ID 3.0 cuffed tracheal tube regarding performance time and preference by the operator. Greater force application to advance the cuffed tube over the Frova catheter and more severe airway injuries may argue for the standardised performance of the eFONA technique with a uncuffed tracheal tube in infants.
Asunto(s)
Intubación Intratraqueal/métodos , Sistema Respiratorio/lesiones , Traqueotomía/métodos , Animales , Estudios Cruzados , Diseño de Equipo , Humanos , Lactante , Intubación Intratraqueal/instrumentación , Modelos Animales , Estudios Prospectivos , Conejos , Traqueotomía/educación , Traqueotomía/instrumentaciónRESUMEN
In 1989 the United Nations passed the "United Nations Convention on the Rights of the Child" (UNCRC) and, among others, demanded the highest attainable standard of health for children. Safe Anesthesia for Every Tot (SAFETOTS, www.safetots.org ), an association of internationally active pediatric anesthetists, has derived 10 rights, the 10 R's, which are of essential importance for the pediatric anesthetic practice. The first right (R1) postulates: "Children have the right to enjoy the highest possible standard of health. Children below the age of three years in particular should be treated by experienced anesthesiologists with profound and continuous training and regular activity in pediatric anesthesia. Children with significant comorbidities and those who need highly specialized or major interventions benefit from specialized pediatric anesthesia in pediatric centers". The current situation in pediatric anesthesia care in Germany, Austria and Switzerland does not always meet the requirements demanded by the UNCRC. Anesthesia-related complications are approximately 10 times more frequent in children than in adults. In contrast to adults, children who are injured during anesthesia are often healthy. Severe complications in pediatric anesthesia have a mortality that is several times higher than in adult anesthesia. There are hardly any statistics on this for German-speaking countries but corresponding cases frequently occur in the context of expert opinions in liability litigation and in the press. Anesthesiologists are often charged with the anesthetic care of newborns, infants and small children without having sufficient child-specific expertise, which results in morbidity and mortality. In some places, only a few babies per year undergo general anesthesia in clinics without a specialized pediatric anesthesia team or a small number of infant anesthesia cases are divided among a large number of anesthesiologists. These case numbers are not even sufficient to maintain a single pediatric anesthesiologist in training in this age group.Changes are needed to guarantee children the right to enjoy the highest attainable standard of health. We need decision-makers, politicians and professional representatives who rethink and who are willing to implement the UNCRC. This includes changing the current financing of hospitals in order that the quality actually provided is financed. The "pay for performance" must change to "pay for quality". In addition to broad basic pediatric care, all complex forms of pediatric treatment must be carried out in specialized pediatric centers, particularly for small and severely ill children.Significant improvement can be achieved at the local level by reorganization, bundling of pediatric surgical interventions within a clinical unit together with the concentration on a dedicated team.
Asunto(s)
Anestesia , Anestesiología , Adulto , Anestesia/métodos , Anestesiólogos , Anestesiología/educación , Anestesistas , Niño , Preescolar , Alemania , Humanos , Lactante , Recién NacidoRESUMEN
Fevipiprant is an oral, non-steroidal, highly selective, reversible antagonist of the prostaglandin D2 (DP2) receptor. The DP2 receptor is a mediator of inflammation expressed on the membrane of key inflammatory cells, including eosinophils, Th2 cells, type 2 innate lymphoid cells, CD8+ cytotoxic T cells, basophils and monocytes, as well as airway smooth muscle and epithelial cells. The DP2 receptor pathway regulates the allergic and non-allergic asthma inflammatory cascade and is activated by the binding of prostaglandin D2. Fevipiprant is metabolised by several uridine 5'-diphospho glucuronosyltransferase enzymes to an inactive acyl-glucuronide (AG) metabolite, the only major human metabolite. Both fevipiprant and its AG metabolite are eliminated by urinary excretion; fevipiprant is also possibly cleared by biliary excretion. These parallel elimination pathways suggested a low risk of major drug-drug interactions (DDI), pharmacogenetic or ethnic variability for fevipiprant, which was supported by DDI and clinical studies of fevipiprant. Phase II clinical trials of fevipiprant showed reduction in sputum eosinophilia, as well as improvement in lung function, symptoms and quality of life in patients with asthma. While fevipiprant reached the most advanced state of development to date of an oral DP2 receptor antagonist in a worldwide Phase III clinical trial programme, the demonstrated efficacy did not support further clinical development in asthma.
Asunto(s)
Preparaciones Farmacéuticas , Calidad de Vida , Humanos , Inmunidad Innata , Ácidos Indolacéticos , Linfocitos , Prostaglandinas , Piridinas , Receptores de ProstaglandinaRESUMEN
BACKGROUND: There are scant data on the dimensional compatibility of cricothyroidotomy equipment and related airway anatomy. We compared the dimensional design of devices for cricothyroidotomy with anatomical airway data for adult patients. METHODS: For all available cricothyroidotomy equipment the outer diameter was recorded from manufacturer information or, if not available, measured using a sliding calliper. Outer diameters were compared with recently published mean (standard deviation [sd]) values for the height of the cricothyroid membrane obtained from computed tomography, separately for males (7.9 [2.2] mm) and for females (5.9 [1.7] mm). RESULTS: Twenty-one cricothyroidotomy sets (10 uncuffed, 11 cuffed) with 15 differently designed devices were included. Inner diameters of the tubes ranged from 3.5 to 6.0 mm and outer diameters from 5.0 to 11.7 mm. The outer diameter of the 15 different tubes was found to be greater than the mean membrane height of the adult male cricothyroid membrane in eight devices and greater than the mean membrane height for female adults in 10 devices. Considering the lower range of cricothyroid membrane height, 12 tube outer diameters would be too large for male adults and all 15 for female adults in this range. CONCLUSION: The outer diameter of many devices currently marketed for cricothyroidotomy are oversized for adult airway anatomy, particularly for females. For emergency front-of-neck access through the cricothyroid membrane, anatomical data suggest that cricothyroidotomy devices with outer tube diameters of <7 mm for male and <6 mm for female adult patients should be preferred.
Asunto(s)
Cartílago Cricoides/cirugía , Intubación Intratraqueal/instrumentación , Cartílago Tiroides/cirugía , Adulto , Anciano , Cartílago Cricoides/diagnóstico por imagen , Urgencias Médicas , Diseño de Equipo , Femenino , Humanos , Intubación Intratraqueal/efectos adversos , Masculino , Persona de Mediana Edad , Medición de Riesgo , Factores de Riesgo , Factores Sexuales , Cartílago Tiroides/diagnóstico por imagen , Tomografía Computarizada por Rayos XRESUMEN
BACKGROUND: A 'cannot intubate, cannot oxygenate' (CICO) situation is rare in paediatric anaesthesia, but can always occur in children under certain emergency situations. There is a paucity of literature on specific procedures for securing an emergency invasive airway in children younger than 6 yr. A modified emergency front of neck access (eFONA) technique using a rabbit cadaver model was developed to teach invasive airway protection in a CICO situation in children. METHODS: After watching an instructional video of our eFONA technique (tracheotomy, intubation with Frova catheter over which a tracheal tube is inserted), 29 anaesthesiologists performed two separate attempts on rabbit cadavers. The primary outcome was the success rate and the performance time overall and in subgroups of trained and untrained participants. RESULTS: The overall success rate across 58 tracheotomies was 95% and the median performance time was 67 s (95% confidence interval [CI], 56-76). Performance time decreased from the first to the second attempt from 72 s (95% CI, 57-81) to 61 s (95% CI, 50-81). Performance time was 59 s (95% CI, 49-79) for untrained participants and 72 s (95% CI, 62-81) for trained participants. Clinical experience and age of the participants was not correlated with performance time, whereas the length of the tracheotomy incision showed a significant correlation (P=0.006). CONCLUSION: This eFONA training model for children facilitates rapid skill acquisition under realistic anatomical conditions to perform an emergency invasive airway in children younger than 2 yr.
Asunto(s)
Manejo de la Vía Aérea/normas , Competencia Clínica/normas , Intubación Intratraqueal/normas , Maniquíes , Traqueotomía/educación , Traqueotomía/normas , Manejo de la Vía Aérea/métodos , Anestesiólogos/educación , Anestesiólogos/normas , Animales , Niño , Preescolar , Humanos , Lactante , Recién Nacido , Intubación Intratraqueal/métodos , Conejos , Traqueotomía/métodosRESUMEN
BACKGROUND: Flexible bronchoscope-guided tracheal intubation through supraglottic airway devices (SGAs) is a well-established element of difficult intubation algorithms. Success can be limited by dimensional incompatibilities between tracheal tubes (TTs) and SGAs. METHODS: In this in vitro study, we tested the feasibility of TT passage through SGAs, removal of SGAs over TTs, and the ability to guide the flexible bronchoscope with 13 TT brands (internal diameter, 6.5-8.0 mm) and ten different SGAs (#4 and #5) in an intubation mannequin. RESULTS: We tested 1,040 combinations of SGAs and TTs. Tracheal tube passage failed in 155 (30%) combinations of the five tested first-generation SGAs (117 [46%] with SGA #4, 38 [15%] with SGA #5) and in three (0.6%) combinations of the five tested second-generation SGAs (two [0.8%] with SGA #4 and one [0.4%] with SGA #5). The reason for failed passage of a TT through a first-generation SGA consistently was a too-narrow SGA connector. Removal of the SGA over the TT in the 882 remaining combinations was impossible for all sizes of reinforced TTs, except the Parker Reinforced TT, and was possible for all non-reinforced TTs. Only one combination with SGA #4 and 84 combinations with SGA #5 were not ideal to adequately guide the flexible bronchoscope. CONCLUSION: Clinically relevant combinations of adult-size TTs and SGAs can be incompatible, rendering flexible bronchoscope-guided tracheal intubation through an SGA impossible. Additional limitations exist regarding removal of the SGA and maneuverability of the flexible bronchoscope.
RéSUMé: CONTEXTE: L'intubation endotrachéale guidée par bronchoscope flexible via un dispositif supraglottique (DSG) est un élément établi des algorithmes utilisés pour les intubations difficiles. La réussite de l'intubation peut être limitée par des incompatibilités dimensionnelles entre les tubes endotrachéaux (TET) et les DSG. MéTHODE: Dans cette étude in vitro, nous avons testé la faisabilité de faire passer un TET par un DSG, le retrait du DSG par-dessus le TET et la possibilité de guider un bronchoscope flexible avec 13 marques de TET (diamètre interne, 6,5-8,0 mm) et dix DSG différents (#4 et #5) sur un mannequin d'intubation. RéSULTATS: Nous avons testé 1040 combinaisons de DSG et de TET. Le passage du tube endotrachéal a échoué dans 155 (30 %) combinaisons avec les cinq DSG de première génération testés (117 [46 %] avec DSG #4, 38 [15 %] avec DSG #5) et dans trois (0,6 %) combinaisons avec les cinq DSG de deuxième génération testés (deux [0,8 %] avec DSG #4 et une [0,4 %] avec DSG #5). La raison de l'échec du passage d'un TET à travers un DSG de première génération était systématiquement liée à un connecteur de DSG trop étroit. Dans les 882 combinaisons restantes, le retrait du DSG par-dessus le TET s'est avéré impossible avec toutes les tailles de TET armés, à l'exception du TET armé Parker, et était possible avec tous les TET non armés. Une seule combinaison avec le DSG #4 et 84 combinaisons avec le DSG #5 n'étaient pas idéales pour guider le bronchoscope flexible de manière adéquate. CONCLUSION: Les combinaisons cliniquement pertinentes de TET et de DSG de tailles adultes peuvent être incompatibles, rendant impossible l'intubation endotrachéale guidée par bronchoscope flexible via un DSG. D'autres limites existent en ce qui concerne le retrait du DSG et la maniabilité du bronchoscope flexible.
Asunto(s)
Máscaras Laríngeas , Maniquíes , Adulto , Broncoscopía , Humanos , Intubación Intratraqueal , Respiración ArtificialRESUMEN
BACKGROUND: In clinical practice, the cuff inflation line of cuffed pediatric tracheal tubes often interferes with securing tracheal tubes. METHODS: The insertion site of the cuff inflation lines and the lengths of four different brands and nine sizes of commonly used cuffed pediatric tracheal tubes were measured and compared in vitro with oral and nasotracheal intubation depths as calculated by different formulas for pediatric patients aged from birth to 16 years. Motoyama's recommendation was used for age-related size selection of cuffed pediatric tracheal tubes. RESULTS: The proportion of the distance from the tracheal tube tip to the insertion site of the cuff inflation line varied considerably between the tracheal tubes (Microcuff: 48.5-60.7%; Parker: 48.7-73.2%; Ruesch: 59.1-77.8%; and Shiley: 46.0-60.3%). Using different formulas for oral or nasotracheal intubation depth, the insertion site of the cuff inflation line was placed within the oral or nasal cavity or within an area 1 cm beyond the teeth or the nostrils in almost all tracheal tubes tested. Positioning the insertion site 2 cm from the proximal end of the tracheal tubes resulted in a cuff line-free tube area of ≥1 cm in all orally and almost in all nasally inserted tracheal tubes, considering maximum recommended tracheal intubation depths. CONCLUSION: The cuff inflation line in almost all commonly used cuffed pediatric tracheal tubes interferes with securing the tracheal tube due to its insertion site into the tracheal tube. This potentially carries the risk of kinking, obstruction, or damage to the cuff inflation line with ensuing failure to deflate or inflate the cuff. The proposed position of the insertion of the cuff inflation line 2 cm from the proximal end of the tracheal tube would ensure a 1-cm-wide cuff line-free circular area beyond the oral or nasal cavity in nearly all assessed tracheal tube sizes.
Asunto(s)
Insuflación , Tráquea , Niño , Diseño de Equipo , Humanos , Intubación Intratraqueal , Respiración ArtificialRESUMEN
BACKGROUND: Large prospective clinical studies have shown that modern cuffed pediatric tracheal tubes can be used safely, even in children weighing ≥3 kg. There is a growing interest in their use in children weighing <3 kg so that they, too, can benefit from the potential advantages, particularly the high probability of these tubes fitting into and sealing the pediatric airway at the first intubation attempt. This study aimed to find a cut-off body weight for procedures requiring a cuffed tracheal tube to seal the airway in children weighing <3 kg and to evaluate the frequency and predictive factors for the requirement to place a cuffed instead of an uncuffed tracheal tube. METHODS: This study was a retrospective analysis of 269 children weighing 2000-2999 g, primarily intubated by pediatric anesthetists. Frequency of intubation with uncuffed Sheridan tubes versus cuffed Microcuff® Pediatric Endotracheal Tube (PET) 3.0 mm ID was studied. Predictive variables were assessed by means of logistic regression analysis. The ROC curve for weight at intubation time and Youden index was calculated. RESULTS: The 149 (55.4%) children were finally intubated with a cuffed tracheal tube. Logistic regression demonstrated that body weight at tracheal intubation and birth weight were the strongest predictors for the appropriateness of cuffed/uncuffed tracheal tubes. The threshold weight at tracheal intubation was 2700 g for a probability >50% of using a cuffed tracheal tube. CONCLUSION: Half of the children weighing 2000-2999 g received a Microcuff® PET 3.0 mm ID, especially those with a body weight above 2700 g. Because of the anatomical dimensions in patients with a body weight of 2000-2999 g, cuffed tracheal tubes with smaller outer diameters may be required to better fit their airways.
Asunto(s)
Intubación Intratraqueal , Peso Corporal , Niño , Diseño de Equipo , Humanos , Lactante , Recién Nacido , Estudios Prospectivos , Estudios RetrospectivosRESUMEN
BACKGROUND: Balloon-tipped bronchial blocker catheters are widely used in pediatric thoracic anesthesia to establish single-lung ventilation. In clinical practice, their balloons demonstrate sudden expansion when inflated with air. In addition, there are concerns related to the high inflation pressures required to expand the balloons. METHODS: This in vitro study assessed inflation volume- and inflation pressure-balloon diameter characteristics of the Fogarty arterial embolectomy catheters and Arndt endobronchial blockers. Balloon diameters were photographically assessed during unrestricted volume- and pressure-guided inflation, using air up to the maximum allowed inflation volume as indicated by the manufacturers. Inflation pressures required to open the blocker balloons and inflation pressures needed to expand them to maximum indicated diameter were measured. RESULTS: Volume-guided inflation demonstrated a late acute rise in diameter in Fogarty blocker balloons, whereas in the Arndt endobronchial blocker balloons almost linear inflation volume-to-diameter characteristics were observed. Pressure-guided inflation on the other hand demonstrated low-volume, high-pressure characteristics in the Fogarty blocker balloons, with inflation pressures required to expand the balloons to maximum diameters ranging from (mean (SD)) 636 (75) to 947 (152) cmH2 O. The inflation pressures required to open the Fogarty blocker balloons were even >1000 cmH2 O. Inflation pressures required to expand the 5 F, 7 F, and 9 F Arndt endobronchial blocker balloons to maximum indicated diameter were much lower, namely at 218 (15), 252 (28), and 163 (8) cmH2 O. CONCLUSION: Based on these study findings, the balloons of Fogarty arterial embolectomy catheters represent high-pressure devices and do not permit stepwise controlled bronchial blockage. The Arndt endobronchial blockers have some advantages over the Fogarty blocker devices, but also represent high-pressure equipment and must be used with caution and limited duration. Manufacturers are asked to design pediatric endobronchial blocker catheters with truly high-volume, low-pressure balloons in accordance to age-related pediatric airway dimensions.
Asunto(s)
Insuflación , Ventilación Unipulmonar , Bronquios , Cateterismo , Niño , HumanosRESUMEN
BACKGROUND: Appropriate size selection of pediatric rigid bronchoscopes is fundamental to avoidance of airway trauma and to a high success rate with the first intubation attempt. The aim of the present study was to compare the outer diameters of pediatric rigid bronchoscopes with the anatomical data on the pediatric airway. METHODS: Outer diameters (OD) of pediatric rigid ventilating bronchoscopes as given by the manufacturer were compared with published computed tomography internal diameters (ID) of the cricoid outlet, the trachea as well as the left and right proximal mainstem bronchus, using six published recommendations for age-related size selection. The ratios between a specific OD and ID were calculated and given as percentage values (%) for lower and upper age ranges. RESULTS: Nominal sized 2.5, 3, 3.5, 3.7, 4, 4.5, 5, and 6 rigid bronchoscopes were included. In five recommendations, the rigid bronchoscopes' OD was larger than the internal cricoid diameter in the upper age range, whereas in one recommendation the ratio (OD rigid bronchoscope to ID of cricoid) ranged between 77% and 90% for the upper age and between 95% and 109% for the lower age range. In only one of the six recommendations was the rigid bronchoscope OD larger than the tracheal ID. Ratios for the left and right proximal mainstem bronchus ranged from 70% to 146% for the upper and from 78% to 156% for the lower age range, with the highest ratios for the left proximal mainstem bronchus. CONCLUSION: Based on this in vitro study, most of the recommendations analyzed result in a balanced fit of rigid bronchoscopes within the cricoid. Since the left mainstem bronchus is considerably smaller than the cricoid, any insertion on this level will require careful endoscopic guidance to avoid damage to the left mainstem bronchus.
Asunto(s)
Broncoscopios , Intubación Intratraqueal , Bronquios , Broncoscopía , Niño , Humanos , Tráquea/diagnóstico por imagenRESUMEN
BACKGROUND: Cuffed tracheal tubes have recently been recommended for selective endobronchial intubation to establish single-lung ventilation even in smaller children. This implies that, compared with uncuffed tracheal tubes, the cuffed tracheal tubes selected will be smaller and therefore have a shorter length. We hypothesized that cuffed tracheal tubes might be of insufficient length for selective endobronchial intubation if the tube cuff were fully immersed in the left or right mainstem bronchus. METHODS: The distance from the proximal end of the tracheal tube to the upper border of the cuff in cuffed tracheal tubes and to the upper margin of the Murphy eye in uncuffed tracheal tubes, respectively, was assessed in sizes 3.0-7.0 mm internal diameter. The raw data sets of two previously performed studies obtained from 337 children aged from birth to 16 years, including the distances "teeth to tracheal tube tip" and "tracheal tube tip to carina," were used to calculate age-, weight-, and height-related data for the distance from "teeth to carina." Tracheal tube dimensions were compared with age-related distances from "teeth to carina," applying published recommendations for the selection of uncuffed and cuffed tracheal tubes for selective endobronchial intubation in children. RESULTS: The differences between the length of the age-related tracheal tube and the tracheal tube insertion length required to guarantee full insertion of the tracheal tube cuff or the Murphy eye within the mainstem bronchus ranged from -3.5 to 52.6 mm in cuffed tracheal tubes and from 42.3 to 83.3 mm in uncuffed tracheal tubes. CONCLUSIONS: For many age groups of patients requiring selective endobronchial intubation, the lengths of cuffed tracheal tubes, in contrast to those of uncuffed tracheal tubes, were revealed to be critically short for safe taping outside the oral cavity with the cuff placed completely within the right or left mainstem bronchus.
Asunto(s)
Intubación Intratraqueal , Respiración Artificial , Bronquios , Niño , Diseño de Equipo , Humanos , TráqueaRESUMEN
BACKGROUND: Syringe infusion pumps are used for the precise continuous administration of intravenous drugs. Their compliance and mechanical deficiencies have been found to cause considerable start-up delays, flow irregularities during vertical displacement, as well extensive delays of occlusion alarms at low infusion rates. The aim of this study was to evaluate the performance of several modern syringe infusion pumps at low infusion rates and the impact on drug concentration. METHODS: Seven currently marketed syringe infusion pump assemblies were assessed in an in vitro study during start-up, vertical displacement manoeuvres, and infusion line occlusion at a set flow rate of 1 ml h-1. The measured data were used as input for a pharmacokinetic simulation modelling plasma concentration during a standard neonatal continuous epinephrine infusion. RESULTS: The mean time from starting the infusion pump to steady-state flow varied from 89 to 1622 s. The zero-drug delivery time after lowering the pump ranged from 145 to 335 s. In all assemblies tested, occlusion alarm delays and measured flow irregularities during vertical displacement manoeuvres resulted in relevant deviations in plasma epinephrine concentration (>25%) as calculated by the pharmacokinetic simulation model. CONCLUSION: Problems with the performance of syringe infusion pump assemblies can have considerable impact on plasma drug concentration when highly concentrated short-acting cardiovascular drugs are administered at low flow rates. The problems, which affected all assemblies tested, are mainly related to the functional principle of syringe infusion pumps and will only partially be solved by incremental improvements of existing equipment.