Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 193
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Anesth Analg ; 138(6): 1163-1172, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38190339

RESUMEN

BACKGROUND: Optimal analgesic protocols for total knee arthroplasty (TKA) patients remain controversial. Multimodal analgesia is advocated, often including peripheral nerve blocks and/or periarticular injections (PAIs). If 2 blocks (adductor canal block [ACB] plus infiltration between the popliteal artery and capsule of the knee [IPACK]) are used, also performing PAI may not be necessary. This noninferiority trial hypothesized that TKA patients with ACB + IPACK + saline PAI (sham infiltration) would have pain scores that were no worse than those of patients with ACB + IPACK + active PAI with local anesthetic. METHODS: A multimodal analgesic protocol of spinal anesthesia, ACB and IPACK blocks, intraoperative ketamine and ketorolac, postoperative ketorolac followed by meloxicam, acetaminophen, duloxetine, and oral opioids was used. Patients undergoing primary unilateral TKA were randomized to receive either active PAI or control PAI. The active PAI included a deep injection, performed before cementation, of bupivacaine 0.25% with epinephrine, 30 mL; morphine; methylprednisolone; cefazolin; with normal saline to bring total volume to 64 mL. A superficial injection of 20 mL bupivacaine, 0.25%, was administered before closure. Control injections were normal saline injected with the same injection technique and volumes. The primary outcome was numeric rating scale pain with ambulation on postoperative day 1. A noninferiority margin of 1.0 was used. RESULTS: Ninety-four patients were randomized. NRS pain with ambulation at POD1 in the ACB + IPACK + saline PAI group was not found to be noninferior to that of the ACB + IPACK + active PAI group (difference = 0.3, 95% confidence interval [CI], [-0.9 to 1.5], P = .120). Pain scores at rest did not differ significantly among groups. No significant difference was observed in opioid consumption between groups. Cumulative oral morphine equivalents through postoperative day 2 were 89 ± 40 mg (mean ± standard deviation), saline PAI, vs 73 ± 52, active PAI, P = .1. No significant differences were observed for worst pain, fraction of time in severe pain, pain interference, side-effects (nausea, drowsiness, itching, dizziness), quality of recovery, satisfaction, length of stay, chronic pain, and orthopedic outcomes. CONCLUSIONS: For TKA patients given a comprehensive analgesic protocol, use of saline PAI did not demonstrate noninferiority compared to active PAI. Neither the primary nor any secondary outcomes demonstrated superiority for active PAI, however. As we cannot claim either technique to be better or worse, there remains flexibility for use of either technique.


Asunto(s)
Anestésicos Locales , Artroplastia de Reemplazo de Rodilla , Bloqueo Nervioso , Dolor Postoperatorio , Arteria Poplítea , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Masculino , Femenino , Anciano , Dolor Postoperatorio/tratamiento farmacológico , Dolor Postoperatorio/prevención & control , Dolor Postoperatorio/diagnóstico , Dolor Postoperatorio/etiología , Persona de Mediana Edad , Bloqueo Nervioso/métodos , Arteria Poplítea/cirugía , Inyecciones Intraarticulares , Anestésicos Locales/administración & dosificación , Dimensión del Dolor , Resultado del Tratamiento , Método Doble Ciego , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Analgesia/métodos
2.
Artículo en Inglés | MEDLINE | ID: mdl-38738862

RESUMEN

PURPOSE: The purpose of this study was to examine the effects of intraoperative technology use on the rate of using polyethylene liners 15 mm or greater during primary total knee arthroplasty (TKA). METHODS: There were 103,295 implants from 16,386 primary unilateral TKAs performed on 14,253 patients at a single institution between 1 January 2018, and 30 June 2022, included in the current study. Robotic assistance and navigation guidance were used in 1274 (8%) and 8345 (51%) procedures, respectively. The remaining 6767 TKAs (41%) were performed manually. Polyethylene liners were manually identified and further subcategorised by implant thickness. Patients who underwent robotic-assisted TKA were younger (p < 0.001) and more likely to be male (p < 0.001) compared to patients who underwent navigation-guided or manual TKAs. RESULTS: Average polyethylene liner thickness was similar between groups (10.5 ± 1.5 mm for robotic-assisted TKAs, 10.9 ± 1.8 mm for navigation-guided TKAs and 10.8 ± 1.8 mm for manual TKAs). The proportions of polyethylene liners 15 mm or greater used were 4.9%, 3.8% and 1.9% for navigation-guided, manual and robotic-assisted procedures, respectively (p < 0.001). Multivariate regression analyses demonstrated that navigation-guided (odds ratio [OR]: 2.6, 95% confidence Interval [CI]: [1.75-4.07], p < 0.001) and manual (OR: 2.0, 95% CI: [1.34-3.20], p = 0.001) procedures were associated with an increased use of polyethylene liners 15 mm or greater. CONCLUSION: Robotic-assisted TKA was associated with a lower proportion of polyethylene liners 15 mm or greater used compared to navigation-guided and manual TKA. These findings suggest that robotic assistance can reduce human error via a more precise cutting system, limit over-resection of the tibia and flexion-extension gap mismatch and ultimately allow for more appropriately sized implants. LEVEL OF EVIDENCE: Level III, retrospective cohort study.

3.
J Arthroplasty ; 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38735554

RESUMEN

BACKGROUND: Interprosthetic femur fractures (IPFFs) are a rare, but devastating complication following total joint arthroplasty. There is limited evidence to help guide their management. The purpose of this study was to describe the features, treatment, and outcomes of surgically managed IPFFs. METHODS: We retrospectively identified 75 patients who had 76 IPFFs. The mean age at the time of IPFF was 75 years (range, 29 to 94), and 78% were women. The mean body mass index was 30 (range, 19 to 51), and the mean follow-up was 3 years (range, 0 to 14). There were 16 Vancouver B1 fractures, 28 Vancouver B2 fractures, 2 Vancouver B3 fractures, and 30 Vancouver C fractures. All B1 fractures underwent open reduction internal fixation (ORIF). All Vancouver B2 and B3 fractures underwent revision arthroplasty, including 1 proximal femur replacement and 1 total femur replacement. Vancouver C fractures were treated with ORIF (n = 20), distal femoral replacement (n = 9), and in 1 case, total femur replacement (n = 1). Kaplan-Meier survivorship was used to calculate 2-year survival free from all-cause reoperation and periprosthetic joint infection (PJI). RESULTS: The 2-year survivorship-free rate from reoperation was 71%. There were 18 reoperations following initial surgical management of the IPFF, including 9 for infection, 3 for refracture, 3 for nonunion, 2 for hardware failure, and 1 for instability. An initial IPFF involving a stemmed femoral total knee arthroplasty component was associated with increased risk for reoperation (P = .007) and PJI (P = .044). There was no difference in survivorship free of reoperation between IPFFs managed with ORIF or revision arthroplasty (P = .72). CONCLUSIONS: An IPFF is a devastating complication following total joint arthroplasty with high reoperation rates, most commonly secondary to PJI. Those IPFFs that occurred between 2 stemmed components were at the highest risk for reoperation.

4.
J Arthroplasty ; 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38642850

RESUMEN

BACKGROUND: Identification of femoral component debonding in the work-up of painful total knee arthroplasty (TKA) often poses a diagnostic challenge. The purpose of this study was to compare the sensitivity and specificity of radiographs, computed tomography (CT), and magnetic resonance imaging (MRI) for identifying femoral component loosening with debonding at the time of revision of a primary TKA with a recalled polyethylene insert. METHODS: Using an institutional database, we identified all cases of revision TKA performed for this specific implant recall following a primary TKA between 2014 and 2022. Patients who had a preoperative radiograph, CT, and MRI were included (n = 77). Sensitivity, specificity, and positive and negative likelihood ratio (LR) for predicting loosening were compared among the imaging modalities, using the intraoperative evidence of implant loosening as the gold standard. RESULTS: At the time of revision surgery, the femoral component was noted to have aseptic loosening with debonding in 46 of the 77 (60%) of the TKAs. There were no significant differences in demographics in the cohort with femoral debonding compared to those with well-fixed implants. The CT demonstrated a sensitivity of 28% and a specificity of 97%, while the MRI demonstrated a sensitivity of 37% and a specificity of 94% for detecting femoral loosening due to debonding. Both CT and MRI demonstrated poor negative LRs for femoral loosening (LR 0.7). CONCLUSIONS: In this series of revision TKAs for a specific recalled component, neither CT nor MRI accurately diagnosed femoral component debonding. For patients who have this implant, it is imperative to interrogate the implant-cement interface intraoperatively and prepare for full revision surgery as well as marked bone loss secondary to osteolysis.

5.
J Arthroplasty ; 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38599529

RESUMEN

BACKGROUND: Partial or total release of the posterior cruciate ligament (PCL) is often performed intraoperatively in cruciate-retaining total knee arthroplasty (CR-TKA) to alleviate excessive femoral rollback. However, the effect of the release of selected fibers of the PCL on femoral rollback in CR-TKA is not well understood. Therefore, we used a computational model to quantify the effect of selective PCL fiber releases on femoral rollback in CR-TKA. METHODS: Computational models of 9 cadaveric knees (age: 63 years, range 47 to 79) were virtually implanted with a CR-TKA. Passive flexion was simulated with the PCL retained and after serially releasing each individual fiber of the PCL, starting with the one located most anteriorly and laterally on the femoral notch and finishing with the one located most posteriorly on the medial femoral condyle. The experiment was repeated after releasing only the central PCL fiber. The femoral rollback of each condyle was defined as the anterior-posterior distance between tibiofemoral contact points at 0° and 90° of flexion. RESULTS: Release of the central PCL fiber in combination with the anterolateral (AL) fibers, reduced femoral rollback a median of 1.5 [0.8, 2.1] mm (P = .01) medially and by 2.0 [1.2, 2.5] mm (P = .04) laterally. Releasing the central fiber alone reduced the rollback by 0.7 [0.4, 1.1] mm (P < .01) medially and by 1.0 [0.5, 1.1] mm (P < .01) laterally, accounting for 47 and 50% of the reduction when released in combination with the AL fibers. CONCLUSIONS: Releasing the central fibers of the PCL had the largest impact on reducing femoral rollback, either alone or in combination with the release of the entire AL bundle. Thus, our findings provide clinical guidance regarding the regions of the PCL that surgeons should target to reduce femoral rollback in CR-TKA.

6.
Artículo en Inglés | MEDLINE | ID: mdl-38662001

RESUMEN

INTRODUCTION: Options for soft tissue coverage in revision total knee arthroplasty (rTKA) range from primary wound closure to complex muscle flap reconstructions. The purpose of this study was to investigate the institutional experience of wound coverage options for complex soft tissue defects in rTKA. MATERIALS AND METHODS: 77 patients undergoing rTKA with complex wound closure by a single plastic surgeon were retrospectively reviewed. The average follow-up was 30.1 months. In 18 (23.4%) patients, an intraoperative decision for primary closure was made. Fifty-nine patients (76.6%) received either a local fasciocutaneous (N = 18), a medial gastrocnemius (N = 37), a free latissimus dorsi (N = 3) or a lateral gastrocnemius flap (N = 1). Revision-free survival and complication rates were assessed and risk factors were analyzed with Cox-regression analysis. RESULTS: Medial gastrocnemius flaps had significant lower cumulative revision-free survival rates than local fasciocutaneous flaps (P = 0.021) and primary closures (P < 0.001) (42.5% vs. 71.5% vs. 100%,respectively). Comparing the most common complex closure procedures medial gastrocnemius flaps had the highest rate of prolonged wound healing (29.7%) and infection/reinfection (40.5%). Infection-associated flap procedures had significant lower cumulative revision-free survival rates (30.5%) than non-infection associated flap procedures (62.8%,P = 0.047). A history of more than two prior surgeries (HR = 6.11,P < 0.001) and an age ≥ 65 years (HR = 0.30,P = 0.018) significantly increased the risk of revision. CONCLUSIONS: The results of this study indicate that primary closure -if possible- should be preferred to early proactive muscle flap coverage. Even in the hands of an experienced plastic surgeon muscle flaps have high revision and complication rates. The study highlights the need to clarify flap indications and to investigate alternative approaches.

7.
J Arthroplasty ; 38(6): 1172-1176, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36878437

RESUMEN

BACKGROUND: Dual mobility (DM) liners were introduced to reduce instability in total hip arthroplasty. They were found to allow for motion predominantly at the femoral head and the inner bearing of the acetabular liner; however, little is known if this motion is sufficient to alter polyethylene material characteristics. We assessed cross-link (XL) density and oxidation index (OI) measurements of the inner and outer bearing articulations. METHODS: Thirty-seven DM liners were collected with a duration of implantation greater than 2 years. Clinical and demographic data were collected from a chart review. A cylinder was cored from the apex of each liner and cut into 4.5 mm long inner and outer diameter segments for XL density swell ratio testing. The OI was measured from sagittal 100 µm microtome slices using Fourier transform infrared spectroscopy. Student's t-tests were used to determine differences in OI and XL density between the bearings. Spearman's correlation assessed relationships between patient demographics, OI, and XL density. Duration of implantation for the cohort was a mean of 35 (range, 24-96) months. RESULTS: The inner and outer bearing had similar median XL densities (0.17 mol/dm3 versus 0.17 mol/dm3, P = .6). The inner bearing had an increased OI when compared to the outer bearing (0.16 versus 0.13, P = .008). The OI was inversely correlated with XL density (r = -0.50, P = .002). CONCLUSION: Small differences were found in oxidation between the inner and outer bearing of the DM construct. Failures at an average of 3 years indicate low levels of oxidation, unlikely to impact the mechanical properties of the material.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Polietileno , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Polietileno/química , Diseño de Prótesis , Falla de Prótesis
8.
J Arthroplasty ; 38(6S): S363-S367, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36813214

RESUMEN

BACKGROUND: Fractures of the polyethylene post are a rare but known complication after posterior-stabilized (PS) total knee arthroplasty (TKA). We evaluated the polyethylene and patient characteristics for 33 primary PS polyethylene components that were revised with fractured posts. METHODS: We identified 33 PS inserts revised between 2015 and 2022. Patient characteristics collected included age at index TKA, sex, body mass index, length of implantation (LOI), and patient-reported details on events surrounding the post fracture. Implant characteristics recorded were manufacturer, cross-linking properties (highly cross-linked polyethylene [XLPE] versus ultra-high molecular weight polyethylene [UHMWPE]), wear characteristics based on subjective scoring of the articular surfaces and scanning electron microscopy (SEM) of fracture surfaces. Mean age at index surgery was 55 years (range, 35 to 69), mean body mass index was 29.5 (range, 18.5 to 37.2), and mean LOI was 10.0 (range, 4 to 26). RESULTS: Total surface damage scores were significantly higher in the UHMWPE group versus the XLPE group (57.3 versus 44.2, P = .003). SEM demonstrated fracture initiation at the posterior edge of the post in 10 of 13 cases. UHMWPE fracture surfaces posts had more tufted, irregularly clamshell features, while XLPE posts had more precise clamshell marking and a diamond pattern in the region of acute, final fracture. CONCLUSION: Characteristics of PS post fracture differed between XLPE and UHMWPE implants, with fractures occurring in the XLPE with less generalized surface damage, after a shorter LOI, and with SEM evaluation indicative of a more brittle fracture pattern.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Fracturas Óseas , Prótesis de la Rodilla , Polietileno , Adulto , Anciano , Humanos , Persona de Mediana Edad , Artroplastia de Reemplazo de Rodilla/efectos adversos , Fracturas Óseas/cirugía , Articulación de la Rodilla/cirugía , Diseño de Prótesis , Falla de Prótesis
9.
J Arthroplasty ; 38(10): 2131-2136, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37142071

RESUMEN

BACKGROUND: Despite renewed interest in cementless fixation of total knee implants, many surgeons have anecdotal concerns about slower recovery and higher early pain scores. We sought to analyze 90-day opioid utilizations, inhospital pain scores, and patient-reported outcome measures (PROMs) in patients undergoing primary cemented versus cementless total knee arthroplasty (TKA). METHODS: We retrospectively identified a cohort of opioid naïve patients undergoing primary TKA for osteoarthritis. There were 186 patients who had cementless TKAs matched 1:6 with 1,116 who received a cemented TKAs based on age (±6 years), body mass index (BMI) (±5), and sex. We compared inhospital pain scores, 90-day opioid utilizations in morphine milligram equivalents (MMEs), and early postoperative PROMs. RESULTS: The cemented and cementless cohorts had similar lowest (0.09 versus 0.08), highest (7.36 versus 7.34), and average (3.26 versus 3.27) pain scores using numeric rating scale (P > .05). They received similar inhospital (90 versus 102, P = .176), discharge (315 versus 315, P = .483), and total (687 versus 720, P = .547) MMEs. They had similar average inpatient hourly opioid consumption (2.5 versus 2.5 MMEs/hour, P = .965). Average refills 90 days postoperatively were similar in both cohorts (1.5 versus 1.4 refills, P = .893). Also, preoperative, 6-week, 3-month, delta 6-week, and delta 3-month PROMs scores were similar between cemented and cementless cohorts (P > .05) CONCLUSION: This matched study demonstrated similar in-hospital pain scores and opioid utilization, total MMEs prescribed within 90 days, and PROMs at 6 weeks and 3 months postoperatively between cemented and cementless TKAs. LEVEL OF EVIDENCE: III, retrospective cohort study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Humanos , Analgésicos Opioides/uso terapéutico , Estudios Retrospectivos , Pacientes Internos , Dolor
10.
J Arthroplasty ; 38(6S): S190-S195, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36813213

RESUMEN

BACKGROUND: Knee instability is a leading cause of dissatisfaction following total knee arthroplasty (TKA). Instability can involve abnormal laxity in multiple directions including varus-valgus (VV) angulation, anterior-posterior (AP) translation, and internal-external rotation (IER). No existing arthrometer objectively quantifies knee laxity in all three of these directions. The study objectives were to verify the safety and assess reliability of a novel multiplanar arthrometer. METHODS: The arthrometer utilized a five degree-of-freedom instrumented linkage. Two examiners each conducted two tests on the leg that had received a TKA of 20 patients (mean age 65 years (range, 53-75); 9 men, 11 women), with nine and eleven distinct patients tested at 3-month and 1-year postoperative time points, respectively. AP forces from -10 to 30 Newtons, VV moments of ±3 Newton-meters, and IER moments of ±2.5 Newton-meters were applied to each subject's replaced knee. Severity and location of knee pain during testing were assessed using a visual analog scale. Intraexaminer and interexaminer reliabilities were characterized using intraclass correlation coefficients. RESULTS: All subjects successfully completed testing. Pain during testing averaged 0.7 (out of possible 10; range, 0-2.5). Intraexaminer reliability was >0.77 for all loading directions and examiners. Interexaminer reliability and 95% confidence intervals were 0.85 (0.66-0.94), 0.67 (0.35-0.85), and 0.54 (0.16-0.79) in the VV, IER, and AP directions, respectively. CONCLUSION: The novel arthrometer was safe for evaluating AP, VV, and IER laxities in subjects who had received TKA. This device could be used to examine relationships between laxity and patient perceptions of knee instability.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Inestabilidad de la Articulación , Masculino , Humanos , Femenino , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Reproducibilidad de los Resultados , Fenómenos Biomecánicos , Articulación de la Rodilla/cirugía , Rodilla/cirugía , Inestabilidad de la Articulación/diagnóstico , Inestabilidad de la Articulación/etiología , Inestabilidad de la Articulación/cirugía , Rango del Movimiento Articular
11.
J Arthroplasty ; 38(6S): S290-S296.e1, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36907386

RESUMEN

BACKGROUND: A specific total knee arthroplasty (TKA) implant system was recently recalled for high incidence of early polymeric wear and osteolysis. We analyzed the early outcomes of aseptic revision with these implants. METHODS: We identified 202 aseptic revision TKAs of this implant system performed at a single institution between 2010 and 2020. Revision indications included aseptic loosening (n = 120), instability (n = 55), and polymeric wear/osteolysis (n = 27). Components were revised in 145 cases (72%) and isolated polyethylene insert exchange occurred in 57 cases (28%). Kaplan-Meier and Cox proportional hazards analyses were used to determine survivorship free from all-cause rerevision and rerevision risk factors. RESULTS: At 2 and 5 years, survivorship free from all-cause rerevision was 89 and 76% in the polyethylene exchange cohort versus 92 and 84% in the component revision cohort (P = .5). At 2 and 5 years, survivorship in revision with components from the same manufacturer was 89 and 80% compared to 95 and 86% in revision with components from a different manufacturer (P = .2). Among re-revisions (n = 30), cones (37%), sleeves (7%), hinge/distal femoral replacement implants were frequently used (13%). Men had increased risk for rerevision (hazard ratio = 2.3, P = .04). CONCLUSION: In this series of aseptic revision TKAs performed on a now-recalled implant system, survivorship free from rerevision was lower than expected when components from the same manufacturer were utilized, but comparable to contemporary reports when both the components were revised with an alternative implant system. Metaphyseal fixation with cones and sleeves as well as highly constrained implants was frequently utilized at time of rerevision TKA. LEVEL OF EVIDENCE: Level IV.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteólisis , Masculino , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Osteólisis/epidemiología , Osteólisis/etiología , Osteólisis/cirugía , Falla de Prótesis , Diseño de Prótesis , Prótesis de la Rodilla/efectos adversos , Reoperación , Polietileno , Estudios Retrospectivos , Resultado del Tratamiento , Articulación de la Rodilla/cirugía
12.
Int Orthop ; 47(5): 1243-1247, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36864185

RESUMEN

PURPOSE: Pelvic tilt (PT) is important to consider when planning total hip arthroplasty (THA) due to its dynamic impact on acetabular orientation. The degree of sagittal pelvic rotation varies during functional activities and can be difficult to measure without proper imaging. The purpose of this study was to evaluate PT variation in the supine, standing, and seated positions. METHODS: A multi-centre cross-sectional study was performed that included 358 THA patients who had preo-perative PT measured from supine CT scan and standing and upright seated lateral radiographs. Supine, standing, and seated PT and associated changes between functional positions were evaluated. Anterior PT was assigned a positive value. RESULTS: In the supine position, mean PT was 4° (range, -35° to 20°), where 23% had posterior PT and 69% anterior PT. In the standing position, mean PT was 1° (range, -23° to 29°), where 40% had posterior PT and 54% anterior PT. In the seated position, mean PT was -18° (range, -43° to 47°), where 95% had posterior PT and 4% anterior PT. From standing to seated, the pelvis rotated posteriorly in 97% of cases (maximum 60°) with 16% of cases considered stiff (change ≤ 10°) and 18% of cases considered hypermobile (change ≥ 30°). CONCLUSION: Patients undergoing THA have marked PT variation in the supine, standing, and seated positions. There was wide variability in PT change from standing to seated, with 16% of patients considered stiff and 18% considered hypermobile. Functional imaging should be performed on patients prior to THA to allow for more accurate planning.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Estudios Transversales , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Postura , Pelvis/cirugía
13.
Arch Orthop Trauma Surg ; 143(1): 311-315, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34302523

RESUMEN

INTRODUCTION: A history of COVID-19 (Coronavirus Disease 2019), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) may have an impact on hemoglobin and ferritin levels predisposing patients to increased blood transfusion requirements following total joint arthroplasty (TJA). The current study compares ferritin levels, hemoglobin levels, and transfusion rates between SARS-CoV-2 IgG positive and SARS-CoV-2 IgG negative TJA patients. MATERIALS AND METHODS: Preoperative ferritin levels, pre- and postoperative hemoglobin levels, postoperative change in hemoglobin, and transfusion rates of 385 consecutive SARS-CoV-2 IgG positive patients undergoing TJA were compared to those of 5156 consecutive SARS-CoV-2 IgG negative patients undergoing TJA. RESULTS: Preoperative hemoglobin levels were significantly lower in SARS-CoV-2 IgG positive patients [13.3 g/dL (range 8.9-17.7 g/dL)] compared to 13.5 g/dl (7.3-18.3 g/dL; p value 0.03). Ferritin levels were significantly lower in SARS-CoV-2 IgG positive patients (mean of 106.1 ng/ml (2.1-871.3.3 ng/ml) vs. 123.7 ng/ml (1.4-1985 ng/ml) (p value 0.02)). Hemoglobin on postoperative day (POD) one, after four-six weeks, and transfusion rates did not differ between the two groups. CONCLUSION: Although preoperative hemoglobin and ferritin levels are lower in SARS-CoV2 IgG positive patients, there was no difference in hemoglobin on POD one, recovery of hemoglobin levels at four-six weeks postoperatively, and transfusion rates after surgery. Routine ferritin testing prior to TJA is not recommended in SARS-CoV-2 IgG positive patients.


Asunto(s)
COVID-19 , Ferritinas , Hemoglobinas , Humanos , Transfusión Sanguínea , Ferritinas/sangre , Hemoglobinas/análisis , Hemorragia , Inmunoglobulina G , SARS-CoV-2 , Periodo Preoperatorio
14.
Arch Orthop Trauma Surg ; 143(11): 6927-6933, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37395854

RESUMEN

INTRODUCTION: Due to the increasing number of total hip arthroplasties (THA), the number and complexity of revision procedures are also on the rise. For complex cases such as periprosthetic joint infections with soft tissue compromise or for abductor muscle deficiencies, one of the treatment options is a gluteus maximus flap (GMF) that covers dead space and can help restore the failed abductor mechanism. The purpose of this study is to investigate the outcomes of a single-plastic surgeon's series of GMF procedures. MATERIALS AND METHODS: This retrospective review reports on 57 patients (mean follow-up 39.2 months) undergoing GMF transfers for abductor insufficiency on native hip (N = 16), for abductor insufficiency in aseptic revision THA (rTHA) (N = 16), for soft tissue defects in aseptic rTHA (N = 8) and for soft tissue defects in septic rTHA (N = 17) by a single plastic surgeon over a 10-year period. Revision-free survival and complication rates were assessed and risk factors were analyzed with Cox-regression analysis. RESULTS: The reoperation-free survival rate of GMF for abductor insufficiency in native hips was 100%. GMF procedures for soft tissue defects in septic rTHA had the lowest cumulative revision-free survival (34.3%) and highest reinfection rates (53.9%). More than three prior surgeries (HR = 2.9, p = 0.020), presence of infection (HR = 3.2, p = 0.010) and resistant organisms (HR = 3.1, p = 0.022) significantly increased the risk of revision. CONCLUSIONS: GMF is a viable option for addressing abductor insufficiency in native hip joints. However, high revision and complication rates are reported for GMF in septic rTHA. This study highlights the need to clarify the circumstances for which the flap reconstruction will be indicated.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Cirujanos , Humanos , Factor de Maduración de la Glia , Colgajos Quirúrgicos/cirugía , Articulación de la Cadera/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Estudios Retrospectivos
15.
Arch Orthop Trauma Surg ; 143(2): 785-789, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34546422

RESUMEN

INTRODUCTION: In the acute phase of COVID-19, elevated D-dimer levels indicate a hypercoagulable state putting the patients at increased risk for venous thromboembolic disease (VTE). It is unclear, if prior COVID-19 disease increases the risk for VTE after total joint arthroplasty (TJA) and if D-dimer levels can be used to identify patients at risk. MATERIALS AND METHODS: D-Dimer levels of 313 consecutive SARS-CoV-2 IgG-positive and 2,053 -negative patients undergoing TJA between 05/20 and 12/20 were evaluated. D-Dimer levels were divided into three groups: < 200 ng/ml, 200-400 ng/ml, and > 400 ng/ml D-dimer units (DDU). 277 SARS-CoV-2 IgG-positive patients underwent a Doppler ultrasound to rule out deep-vein thrombosis (DVT) 4-6 weeks after TJA. RESULTS: D-Dimer levels did not differ significantly between SARS-CoV-2 IgG-positive and -negative patients (p value 0.53). Among SARS-CoV-2 IgG-negative patients, 1687 (82.17%) had D-dimer levels < 200 ng/ml, 256 (12.47%) between 200 and 400 ng/ml, and 110 (5.36%) > 400 ng/ml. Of the SARS-CoV-2 IgG-positive patients, 257 (83.71%) had D-dimer levels < 200 ng/ml, 34 (11.07%) between 200 and 400 ng/ml, and 16 (5.21%) > 400 ng/ml. A postoperative DVT was detected in nine patients (2.9%) in the SARS-CoV-2 IgG-positive group and a PE in one patient (0.3%). 7/229 patients with < 200 ng/ml (3.1%), 1/28 patients (3.6%) with 200-400 ng/ml and 1/9 patients (11.1%) with D-dimer levels > 400 ng/ml had a DVT or PE (p = 0.43). CONCLUSIONS: The findings of this investigation suggest there is no difference in D-dimer levels between SARS-CoV-2 IgG-positive and -negative patients undergoing TJA. Although there is a trend for increased VTE rates with increased D-dimer levels, routine D-dimer testing is not recommended based on the current data. SARS-CoV-2 IgG-positive patients have a low risk of VTE in the current study.


Asunto(s)
COVID-19 , Tromboembolia Venosa , Trombosis de la Vena , Humanos , COVID-19/complicaciones , Tromboembolia Venosa/etiología , SARS-CoV-2 , Trombosis de la Vena/etiología , Artroplastia/efectos adversos
16.
Arch Orthop Trauma Surg ; 143(3): 1579-1591, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35378597

RESUMEN

INTRODUCTION: Elective orthopedic care, including in-person office visits and physical therapy (PT), was halted on March 16, 2020, at a large, urban hospital at the onset of the local COVID-19 surge. Post-discharge care was provided predominantly through a virtual format. The purpose of this study was to assess the impact of postoperative care disruptions on early total knee arthroplasty (TKA) outcomes, specifically 90-day complications, 120-day rate of manipulation under anesthesia (MUA) and 1-year patient-reported outcome measures (PROMs). MATERIALS AND METHODS: Institutional records were queried to identify 624 patients who underwent primary, unilateral TKA for osteoarthritis and who were discharged home between 1/1/20 and 3/15/20. These patients were compared to 558 controls discharged between 1/1/19 and 3/15/2019. Cohort demographics and in-hospital characteristics were equivalent apart from inpatient morphine milligram equivalent (MME) consumption. Patient-reported access to PT (p < 0.001) and post-discharge care (p < 0.001) were worse among study patients. Study patients were prescribed fewer post-discharge PT sessions (19.8 vs. 23.5; p < 0.001) and utilized telehealth more frequently (p < 0.001). Mann-Whitney U, T, Fisher's Exact, and chi-squared tests were used to compare outcomes. RESULTS: Ninety-day CMS complications were lower among study patients (3.5% vs. 5.9%; p = 0.05). Rates of MUA were similar between groups. Study patients reported similar PROMs and marginally inferior VR-12 mental and LEAS functional outcomes at 1 year. CONCLUSION: Disruptions to elective orthopedic care in March 2020 seemed to have had no major consequences on clinical outcomes for TKA patients. Our findings question the usefulness of pre-pandemic post-discharge protocols, which may over-emphasize in-person visits and PT.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , COVID-19 , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Cuidados Posoperatorios , Cuidados Posteriores , Alta del Paciente , Medición de Resultados Informados por el Paciente , Estudios Retrospectivos
17.
Radiology ; 304(1): 128-136, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35315718

RESUMEN

Background Because loosening of total knee arthroplasty (TKA) occurs due to poor osseous integration at component-bone interfaces, interface assessment may be helpful in diagnosing loosening at MRI. Purpose To determine interreader reproducibility for characterizing component interfaces and diagnosing loosening and to evaluate the diagnostic performance of MRI for diagnosing loosening after TKA compared with radiography. Materials and Methods Consecutive knees with TKA that underwent revision between July 2018 and June 2019 and were imaged at MRI and radiography were included in this retrospective study. Interface type (normal, fibrous membrane, fluid, or osteolysis), percent integration (<33%, 33%-66%, or >66%), and presence of bone marrow edema pattern were assessed. Loosening was diagnosed at MRI if no or almost no normal interface was present. Sensitivity and specificity were compared with radiographs by using surgical findings as reference. Gwet agreement coefficient evaluated interreader reproducibility between two readers and multivariable logistic regression assessed risk factors for loosening. Results Among 116 knees in 114 patients (mean age, 63 years ± 10 [SD]; 59 women), 61 of 116 knees (52.6%) had at least one loose component. Interreader reproducibility of MRI was substantial to excellent (Gwet agreement coefficient, 0.67-0.96). Loosening was associated with fluid interface (odds ratio [OR], 20.1; 95% CI: 5.7, 70.9) or osteolysis (OR, 3.1; 95% CI: 1.8, 5.3), absence of any normal interface (OR, 11.8; 95% CI: 6.3, 22.2), poor (<33%) osseous integration (OR, 20.4; 95% CI: 9.7, 42.6), and bone marrow edema pattern (OR, 4.7; 95% CI: 2.8, 7.8). Sensitivity and specificity of MRI for loosening were 84% (27 of 32; 95% CI: 72, 97) and 85% (71 of 84; 95% CI: 77, 92) for the patellar, 31% (eight of 26; 95% CI: 13, 49) and 100% (90 of 90; 95% CI: 100, 100) for the femoral, and 81% (22 of 27; 95% CI: 66, 96) and 98% (87 of 89; 95% CI: 95, 100) for the tibial component, respectively. MRI had higher sensitivity (84% vs 31%; P < .001) but lower specificity (85% vs 96%; P = .003) for patellar component loosening than did radiography, respectively, whereas no evidence of a difference was found for femoral (sensitivity and specificity, MRI vs radiography: 31% vs 46% [P = .20] and 100% vs 99% [P > .99], respectively) or tibial (sensitivity and specificity, MRI vs radiography: 81% vs 70% [P = .16] and 98% vs 97% [P = .32], respectively) component loosening. Conclusion MRI demonstrated substantial to excellent interreader reproducibility and higher sensitivity than did radiography for diagnosing patellar component loosening after total knee arthroplasty. © RSNA, 2022 Online supplemental material is available for this article.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteólisis , Artroplastia de Reemplazo de Rodilla/efectos adversos , Femenino , Humanos , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla/efectos adversos , Imagen por Resonancia Magnética/efectos adversos , Persona de Mediana Edad , Osteólisis/diagnóstico por imagen , Falla de Prótesis , Radiografía , Reoperación/efectos adversos , Reproducibilidad de los Resultados , Estudios Retrospectivos
18.
Clin Orthop Relat Res ; 480(8): 1604-1615, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35323146

RESUMEN

BACKGROUND: In TKA, soft tissue balancing is assessed through manual intraoperative trialing. This assessment is a physical examination via manually applied forces at the ankle, generating varus and valgus moments at the knee while the surgeon visualizes the lateral and medial gaps at the joint line. Based on this examination, important surgical decisions are made that influence knee stability, such as choosing the polyethylene insert thickness. Yet, the applied forces and the assessed gaps in this examination represent a qualitative art that relies on each surgeon's intuition, experience, and training. Therefore, the extent of variation among surgeons in conducting this exam, in terms of applied loads and assessed gaps, is unknown. Moreover, whether variability in the applied loads yields different surgical decisions, such as choice of insert thickness, is also unclear. Thus, surgeons and developers have no basis for deciding to what extent the applied loads need to be standardized and controlled during a knee balance exam in TKA. QUESTIONS/PURPOSES: (1) Do the applied moments in soft tissue assessment differ among surgeons? (2) Do the assessed gaps in soft tissue assessment differ among surgeons? (3) Is the choice of insert thickness associated with the applied moments? METHODS: Seven independent human cadaveric nonarthritic lower extremities from pelvis to toe were acquired (including five females and two males with a mean age of 73 ± 7 years and a mean BMI of 25.8 ± 3.8 kg/m 2 ). Posterior cruciate ligament substituting (posterior stabilized) TKA was performed only on the right knees. Five fellowship-trained knee surgeons (with 24, 15, 15, 7, and 6 years of clinical experience) and one chief orthopaedic resident independently examined soft tissue balance in each knee in extension (0° of flexion), midflexion (30° of flexion), and flexion (90° of flexion) and selected a polyethylene insert based on their assessment. Pliable force sensors were wrapped around the leg to measure the loads applied by each surgeon. A three-dimensional (3D) motion capture system was used to measure knee kinematics and a dynamic analysis software was used to estimate the medial and lateral gaps. We assessed (1) whether surgeons applied different moments by comparing the mean applied moment by surgeons in extension, midflexion, and flexion using repeated measures (RM)-ANOVA (p < 0.05 was assumed significantly different); (2) whether surgeons assessed different gaps by comparing the mean medial and lateral gaps in extension, midflexion, and flexion using RM-ANOVA (p < 0.05 was assumed significantly different); and (3) whether the applied moments in extension, midflexion, and flexion were associated with the insert thickness choice using a generalized estimating equation (p < 0.05 was assumed a significant association). RESULTS: The applied moments differed among surgeons, with the largest mean differences occurring in varus in midflexion (16.5 Nm; p = 0.02) and flexion (7.9 Nm; p < 0.001). The measured gaps differed among surgeons at all flexion angles, with the largest mean difference occurring in flexion (1.1 ± 0.4 mm; p < 0.001). In all knees except one, the choice of insert thickness varied by l mm among surgeons. The choice of insert thickness was weakly associated with the applied moments in varus (ß = -0.06 ± 0.02 [95% confidence interval -0.11 to -0.01]; p = 0.03) and valgus (ß = -0.09 ± 0.03 [95% CI -0.18 to -0.01]; p= 0.03) in extension and in varus in flexion (ß = -0.11 ± 0.04 [95% CI -0.22 to 0.00]; p = 0.04). To put our findings in context, the greatest regression coefficient (ß = -0.11) indicates that for every 9-Nm increase in the applied varus moment (that is, 22 N of force applied to the foot assuming a shank length of 0.4 m), the choice of insert thickness decreased by 1 mm. CONCLUSION: In TKA soft tissue assessment in a human cadaver model, five surgeons and one chief resident applied different moments in midflexion and flexion and targeted different gaps in extension, midflexion, and flexion. A weak association between the applied moments in extension and flexion and the insert choice was observed. Our results indicate that in the manual assessment of soft tissue, changes in the applied moments of 9 and 11 Nm (22 to 27 N on the surgeons' hands) in flexion and extension, respectively, yielded at least a 1-mm change in choice of insert thickness. The choice of insert thickness may be more sensitive to the applied moments in in vivo surgery because the surgeon is allowed a greater array of choices beyond insert thickness. CLINICAL RELEVANCE: Among five arthroplasty surgeons with different levels of experience and a chief resident, subjective soft tissue assessment yielded 1 to 2 mm of variation in their choice of insert thickness. Therefore, developers of tools to standardize soft tissue assessment in TKA should consider controlling the force applied by the surgeon to better control for variations in insert selection.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Inestabilidad de la Articulación , Osteoartritis de la Rodilla , Cirujanos , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Fenómenos Biomecánicos , Cadáver , Femenino , Humanos , Inestabilidad de la Articulación/etiología , Articulación de la Rodilla/cirugía , Masculino , Osteoartritis de la Rodilla/cirugía , Polietilenos , Rango del Movimiento Articular
19.
J Arthroplasty ; 37(3): 444-448.e1, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34808278

RESUMEN

BACKGROUND: Although total hip arthroplasty (THA) and total knee arthroplasty (TKA) are transitioning to surgery centers, there remain limited data on trends, comorbidities, and complications in patients discharged the same day of surgery. In addition, many studies are limited to the Medicare population, excluding a large proportion of outpatient surgery patients. METHODS: Primary, elective THA/TKA cases between 2010 and 2017 were retrospectively identified using the PearlDiver All-Payer Database and separated based on surgery as well as same-day discharge (SDD) or non-SDD. Data were collected on demographics, rates, comorbidities, and complications. Multivariable logistic regression determined adjusted odds ratios (ORs) for 90-day complications requiring readmission for each group. RESULTS: In total, 1,789,601 (68.8% TKA, 31.2% THA) patients were identified where 2.9% of TKAs and 2.2% of THAs were SDD. Annual SDD rates are increasing, with a 15.8% mean annual change for SDD-THA and 11.1% for SDD-TKA (P < .001). SDD patients were younger with fewer comorbidities (P < .001). Regression analysis showed an overall slightly higher OR of complications requiring readmission for SDD-TKA vs non-SDD-TKA (OR 1.14, 95% confidence interval [CI] 1.07-1.21, P < .001). There was no significant difference for SDD-THA vs non-SDD-THA (OR 1.03, 95% CI 0.94-1.13, P = .49). In univariate analysis, SDD-THA vs SDD-TKA had more mechanical complications (P < .001), but less pulmonary embolisms (P < .001). Regression analysis showed a slightly higher risk of complications for SDD-THA vs SDD-TKA (OR 1.19, 95% CI 0.99-1.44, P = .05). CONCLUSION: The prevalence of SDD is rising. SDD-THA is increasing more rapidly than SDD-TKA. SDD patients are generally younger with fewer comorbidities. SDD-TKA has slightly higher odds of complications requiring readmission than non-SDD-TKA. SDD-THA and SDD-TKA have different complication profiles.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Tiempo de Internación , Alta del Paciente , Readmisión del Paciente , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Factores de Riesgo
20.
J Arthroplasty ; 37(3): 544-548, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34883254

RESUMEN

BACKGROUND: There is a paucity of data on blood loss and the risk of allogeneic blood transfusion after simultaneous bilateral total hip arthroplasty (SBTHA) with contemporary blood management including neuraxial anesthesia, routine tranexamic acid use, and a restrictive transfusion protocol. As such, we sought to determine the in-hospital outcomes of SBTHA, specifically analyzing blood loss and the rate and risk factors for transfusion. METHODS: We identified 191 patients who underwent SBTHA at a single institution from 2016 to 2019. No drains were utilized and no patients donated blood preoperatively. Mean age was 59 years with 96 females (50.3%). The surgical approach was posterior in 138 (72.3%) and direct anterior in 53 (27.7%) patients. We analyzed blood loss, the rate of allogeneic blood transfusions, and in-hospital thromboembolic complications. We analyzed risk factors for transfusion with a logistic regression analysis. RESULTS: Twenty-two patients (11.5%) underwent allogeneic blood transfusion. All transfused patients were female. Univariate analysis revealed female gender as a transfusion risk factor since it had statistically significant higher proportion in the transfusion group than the nontransfusion group (100% vs 43.5%, respectively, P < .001). We did not identify any other singular significant risk factors for transfusion in a multivariable regression analysis. However, females with a preoperative Hb <12 had an elevated risk of transfusion at 37.5% (15/40 patients). CONCLUSION: With contemporary perioperative blood management protocols, there is a relatively low (11.5%) risk of a blood transfusion after SBTHA. Females with a lower preoperative Hb (<12 g/dL) had the highest risk of transfusion at 37.5%.


Asunto(s)
Antifibrinolíticos , Artroplastia de Reemplazo de Cadera , Trasplante de Células Madre Hematopoyéticas , Ácido Tranexámico , Antifibrinolíticos/uso terapéutico , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Pérdida de Sangre Quirúrgica , Transfusión Sanguínea , Femenino , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Ácido Tranexámico/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA