Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Anal Chem ; 94(12): 4913-4918, 2022 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-35290016

RESUMEN

Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) mass spectrometry is an ambient-direct sampling method that is being developed for high-throughput, label-free, biochemical screening of large-scale compound libraries. Here, we report the development of an ultra-high-throughput continuous motion IR-MALDESI sampling approach capable of acquiring data at rates up to 22.7 samples per second in a 384-well microtiter plate. At top speed, less than 1% analyte carryover is observed from well-to-well, and signal intensity relative standard deviations (RSD) of 11.5% and 20.9% for 3 µM 1-hydroxymidazolam and 12 µM dextrorphan, respectively, are achieved. The ability to perform parallel kinetics studies on 384 samples with a ∼30 s time resolution using an isocitrate dehydrogenase 1 (IDH1) enzyme assay is shown. Finally, we demonstrate the repeatability and throughput of our approach by measuring 115200 samples from 300 microtiter plate reads consecutively over 5.54 h with RSDs under 8.14% for each freshly introduced plate. Taken together, these results demonstrate the use of IR-MALDESI at sample acquisition rates that surpass other currently reported direct sampling mass spectrometry approaches used for high-throughput compound screening.


Asunto(s)
Ensayos Analíticos de Alto Rendimiento , Espectrometría de Masa por Ionización de Electrospray , Pruebas de Enzimas , Rayos Láser , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
2.
Anal Chem ; 94(39): 13566-13574, 2022 10 04.
Artículo en Inglés | MEDLINE | ID: mdl-36129783

RESUMEN

Mass spectrometry (MS) is the primary analytical tool used to characterize proteins within the biopharmaceutical industry. Electrospray ionization (ESI) coupled to liquid chromatography (LC) is the current gold standard for intact protein analysis. However, inherent speed limitations of LC/MS prevent analysis of large sample numbers (>1000) in a day. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI-MS), an ambient ionization MS technology, has recently been established as a platform for high-throughput small molecule analysis. Here, we report the applications of such a system for the analysis of intact proteins commonly performed within the drug discovery process. A wide molecular weight range of proteins 10-150 kDa was detected on the system with improved tolerance to salts and buffers compared to ESI. With high concentrations and model proteins, a sample rate of up to 22 Hz was obtained. For proteins at low concentrations and in buffers used in commonly employed assays, robust data at a sample rate of 1.5 Hz were achieved, which is ∼22× faster than current technologies used for high-throughput ESI-MS-based protein assays. In addition, two multiplexed plate-based high-throughput sample cleanup methods were coupled to IR-MALDESI-MS to enable analysis of samples containing excessive amounts of salts and buffers without fully compromising productivity. Example experiments, which leverage the speed of the IR-MALDESI-MS system to monitor NISTmAb reduction, protein autophosphorylation, and compound binding kinetics in near real time, are demonstrated.


Asunto(s)
Productos Biológicos , Espectrometría de Masa por Ionización de Electrospray , Descubrimiento de Drogas , Rayos Láser , Proteínas/química , Sales (Química) , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
3.
Anal Chem ; 93(17): 6792-6800, 2021 05 04.
Artículo en Inglés | MEDLINE | ID: mdl-33885291

RESUMEN

Mass spectrometry (MS) can provide high sensitivity and specificity for biochemical assays without the requirement of labels, eliminating the risk of assay interference. However, its use had been limited to lower-throughput assays due to the need for chromatography to overcome ion suppression from the sample matrix. Direct analysis without chromatography has the potential for high throughput if sensitivity is sufficient despite the presence of a matrix. Here, we report and demonstrate a novel direct analysis high-throughput MS system based on infrared matrix-assisted desorption electrospray ionization (IR-MALDESI) that has a potential acquisition rate of 33 spectra/s. We show the development of biochemical assays in standard buffers for wild-type isocitrate dehydrogenase 1 (IDH1), diacylglycerol kinase zeta (DGKζ), and p300 histone acetyltransferase (P300) to demonstrate the suitability of this system for a broad range of high-throughput lead discovery assays. A proof-of-concept pilot screen of ∼3k compounds is also shown for IDH1 and compared to a previously reported fluorescence-based assay. We were able to obtain reliable data at a speed amenable for high-throughput screening of large-scale compound libraries.


Asunto(s)
Ensayos Analíticos de Alto Rendimiento , Espectrometría de Masa por Ionización de Electrospray , Bioensayo , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción
4.
Anal Chem ; 92(14): 9790-9798, 2020 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-32567851

RESUMEN

Antibody-drug conjugates (ADCs) are an increasingly prevalent drug class utilized as chemotherapeutic agents. The complexity of ADCs, including their large size, array of drug conjugation sites, and heterogeneous compositions containing from zero to several payloads, demands the use of advanced analytical characterization methods. Tandem mass spectrometry (MS/MS) strategies, including a variety of bottom-up, middle-down, and even top-down approaches, frequently applied for the analysis of antibodies are increasingly being adapted for antibody-drug conjugates. Middle-down tandem mass spectrometry, often focusing on the analysis of ∼25 kDa protein subunits, offers the potential for complete sequence confirmation as well as the identification of multiple conjugation states. While middle-down studies have been extensively developed for monoclonal antibodies, middle-down characterization of ADCs has been limited by the high complexity of the drug molecules. This study seeks to bridge the gap by utilizing a combination of 193 nm ultraviolet photodissociation (UVPD), electron-transfer dissociation (ETD), and electron-transfer/higher-energy collision dissociation (EThcD). The compilation of these MS/MS methods leads to high sequence coverages of 60-80% for each subunit of the ADC. Moreover, the combined fragmentation patterns provide sufficient information to allow confirmation of both the sequence of the complementarity-determining regions and the payload conjugation sites.


Asunto(s)
Inmunoconjugados/química , Espectrometría de Masas en Tándem/métodos , Secuencia de Aminoácidos , Antineoplásicos/administración & dosificación , Antineoplásicos/química , Fraccionamiento Químico , Subunidades de Proteína
5.
Proteomics ; 19(11): e1800433, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30784174

RESUMEN

Chemical proteomics enables comprehensive profiling of small molecules in complex proteomes. A critical component to understand the interactome of a small molecule is the precise location on a protein where the interaction takes place. Several approaches have been developed that take advantage of bio-orthogonal chemistry and subsequent enrichment steps to isolate peptides modified by small molecules. These methods rely on target identification at the level of mass spectrometry making it difficult to interpret an experiment when modified peptides are not identified. Herein, an approach in which fluorescence-triggered two-dimensional chromatography enables the isolation of small molecule-conjugated peptides prior to mass spectrometry analysis is described. In this study, a bromocoumarin moiety has been utilized that fluoresces and generates a distinct isotopic signature to locate and identify modified peptides. Profiling of a cellular cysteinome with the use of a bromocoumarin tag demonstrates that two-dimensional fluorescence-based chromatography separation can enable the identification of proteins containing reactive cysteine residues. Moreover, the method facilitates the interrogation of low abundance proteins with greater depth and sensitivity than a previously reported isotope-targeted approach. Lastly, this workflow enables the identification of small-molecule modified peptides from a protein-of-interest.


Asunto(s)
Cumarinas/química , Cisteína/análisis , Colorantes Fluorescentes/química , Péptidos/química , Fluorescencia , Halogenación , Humanos , Células K562 , Proteómica/métodos , Espectrometría de Masas en Tándem/métodos
6.
Anal Chem ; 91(4): 2805-2812, 2019 02 19.
Artículo en Inglés | MEDLINE | ID: mdl-30661356

RESUMEN

The synthesis of antibody-drug conjugates (ADCs) using the interchain cysteines of the antibody inherently gives a mixture of proteins with varying drug-to-antibody ratio. The drug distribution profiles of ADCs are routinely characterized by hydrophobic interaction chromatography (HIC). Because HIC is not in-line compatible with mass spectrometry (MS) due to the high salt levels, it is laborious to identify the constituents of HIC peaks. An MS-compatible alternative to HIC is reported here: native reversed phase liquid chromatography (nRPLC). This novel technique employs a mobile phase 50 mM ammonium acetate for high sensitivity in MS and elution with a gradient of water/isopropanol. The key to the enhancement is a bonded phase giving weaker drug-surface interactions compared to the noncovalent interactions holding the antibody-drug conjugates together. The hydrophobicity of the bonded phase is varied, and the least hydrophobic bonded phase in the series, poly(methyl methacrylate), is found to resolve the intact constituents of a model ADC (Ab095-PZ) and a commercial ADC (brentuximab vedotin) under the MS-compatible conditions. The nRPLC-MS data show that all species, ranging from drug-to-antibody ratios of 1 to 8, remained intact in the column. Another desired advantage of the nRPLC is the ability of resolving multiple positional isomers of ADC that are not well-resolved in other chromatographic modes. This supports the premise that lower hydrophobicity of the bonded phase is the key to enabling online nRPLC-MS analysis of antibody-drug conjugates.


Asunto(s)
Antineoplásicos Inmunológicos/análisis , Brentuximab Vedotina/análisis , Cromatografía de Fase Inversa/métodos , Inmunoconjugados/análisis , Acetatos/química , Cromatografía Líquida de Alta Presión/métodos , Interacciones Hidrofóbicas e Hidrofílicas
7.
Rapid Commun Mass Spectrom ; 31(22): 1868-1874, 2017 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-28841760

RESUMEN

RATIONALE: High-throughput screening (HTS) is a critical step in the drug discovery process. However, most mass spectrometry (MS)-based HTS methods require sample cleanup steps prior to analysis. In this work we present the utility of infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) for monitoring an enzymatic reaction directly from a biological buffer system with no sample cleanup and at high throughput. METHODS: IR-MALDESI was used to directly analyze reaction mixtures from a well plate at different time points after reaction initiation. The percent conversion of precursors to products was used to screen the enzyme activity. The reaction was performed with two different concentrations of precursors and enzyme in order to assess the dynamic range of the assay. Eventually, a pseudo-HTS study was designed to investigate the utility of IR-MALDESI screening enzyme activity in a high-throughput manner. RESULTS: IR-MALDESI was able to readily monitor the activity of IDH1 over time at two different concentrations of precursors and enzyme. The calculated Z-factors of 0.65 and 0.41 confirmed the suitability of the developed method for screening enzyme activity in HTS manner. Finally, in a single-blind pseudo-HTS analysis IR-MALDESI was able to correctly predict the identity of all samples, where 8/10 samples were identified with high confidence and the other two samples with lower confidence. CONCLUSIONS: The enzymatic activity of IDH1 was screened by directly analyzing the reaction content from the buffer in well plates with no sample cleanup steps. This proof-of-concept study demonstrates the robustness of IR-MALDESI for direct analysis of enzymatic reactions from biological buffers with no sample cleanup and its immense potential for HTS applications.


Asunto(s)
Descubrimiento de Drogas/métodos , Pruebas de Enzimas/métodos , Ensayos Analíticos de Alto Rendimiento/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Isocitrato Deshidrogenasa/metabolismo , Isocitratos/metabolismo , Ácidos Cetoglutáricos/metabolismo , Modelos Químicos , NADP/metabolismo
9.
Nat Chem Biol ; 9(5): 319-25, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23524983

RESUMEN

In contrast to studies on class I histone deacetylase (HDAC) inhibitors, the elucidation of the molecular mechanisms and therapeutic potential of class IIa HDACs (HDAC4, HDAC5, HDAC7 and HDAC9) is impaired by the lack of potent and selective chemical probes. Here we report the discovery of inhibitors that fill this void with an unprecedented metal-binding group, trifluoromethyloxadiazole (TFMO), which circumvents the selectivity and pharmacologic liabilities of hydroxamates. We confirm direct metal binding of the TFMO through crystallographic approaches and use chemoproteomics to demonstrate the superior selectivity of the TFMO series relative to a hydroxamate-substituted analog. We further apply these tool compounds to reveal gene regulation dependent on the catalytic active site of class IIa HDACs. The discovery of these inhibitors challenges the design process for targeting metalloenzymes through a chelating metal-binding group and suggests therapeutic potential for class IIa HDAC enzyme blockers distinct in mechanism and application compared to current HDAC inhibitors.


Asunto(s)
Inhibidores de Histona Desacetilasas/química , Inhibidores de Histona Desacetilasas/farmacología , Histona Desacetilasas/metabolismo , Zinc/química , Línea Celular Tumoral , Cristalografía por Rayos X , Relación Dosis-Respuesta a Droga , Inhibidores de Histona Desacetilasas/síntesis química , Histona Desacetilasas/genética , Humanos , Modelos Moleculares , Estructura Molecular , Compuestos Organometálicos/síntesis química , Compuestos Organometálicos/química , Compuestos Organometálicos/farmacología , Oxadiazoles/química , Relación Estructura-Actividad , Zinc/metabolismo
10.
Expert Opin Drug Discov ; 19(3): 291-301, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38111363

RESUMEN

INTRODUCTION: Ultra-high-throughput mass spectrometry, uHT-MS, is a technology that utilizes ionization and sample delivery technologies optimized to enable sampling from well plates at > 1 sample per second. These technologies do not need a chromatographic separation step and can be utilized in a wide variety of assays to detect a broad range of analytes including small molecules, lipids, and proteins. AREAS COVERED: This manuscript provides a brief historical review of high-throughput mass spectrometry and the recently developed technologies that have enabled uHT-MS. The report also provides examples and references on how uHT-MS has been used in biochemical and chemical assays, nuisance compound profiling, protein analysis and high throughput experimentation for chemical synthesis. EXPERT OPINION: The fast analysis time provided by uHT-MS is transforming how biochemical and chemical assays are performed in drug discovery. The potential to associate phenotypic responses produced by 1000's of compound treatments with changes in endogenous metabolite and lipid signals is becoming feasible. With the augmentation of simple, fast, high-throughput sample preparation, the scope of uHT-MS usage will increase. However, it likely will not supplant LC-MS for analyses that require low detection limits from complex matrices or characterization of complex biotherapeutics such as antibody-drug conjugates.


Asunto(s)
Descubrimiento de Drogas , Cromatografía Líquida con Espectrometría de Masas , Humanos , Espectrometría de Masas/métodos , Descubrimiento de Drogas/métodos
11.
Artículo en Inglés | MEDLINE | ID: mdl-38991134

RESUMEN

Native mass spectrometry (MS) is a powerful analytical technique to directly probe noncovalent protein-protein and protein-ligand interactions. However, not every MS platform can preserve proteins in their native conformation due to high energy deposition from the utilized ionization source. Most small molecules approved as drugs and in development interact with their targets through noncovalent interactions. Therefore, rapid methods to analyze noncovalent protein-ligand interactions are necessary for the early stages of the drug discovery pipeline. Herein, we describe a method for analyzing noncovalent protein-ligand complexes by IR-MALDESI-MS with analysis times of ∼13 s per sample. Carbonic anhydrase and the kinase domain of Bruton's tyrosine kinase are paired with known noncovalent binders to evaluate the effectiveness of native MS by IR-MALDESI.

12.
Mol Brain ; 17(1): 26, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38778381

RESUMEN

Aggregation of misfolded α-synuclein (α-syn) is a key characteristic feature of Parkinson's disease (PD) and related synucleinopathies. The nature of these aggregates and their contribution to cellular dysfunction is still not clearly elucidated. We employed mass spectrometry-based total and phospho-proteomics to characterize the underlying molecular and biological changes due to α-syn aggregation using the M83 mouse primary neuronal model of PD. We identified gross changes in the proteome that coincided with the formation of large Lewy body-like α-syn aggregates in these neurons. We used protein-protein interaction (PPI)-based network analysis to identify key protein clusters modulating specific biological pathways that may be dysregulated and identified several mechanisms that regulate protein homeostasis (proteostasis). The observed changes in the proteome may include both homeostatic compensation and dysregulation due to α-syn aggregation and a greater understanding of both processes and their role in α-syn-related proteostasis may lead to improved therapeutic options for patients with PD and related disorders.


Asunto(s)
Neuronas , Enfermedad de Parkinson , Agregado de Proteínas , Proteómica , Proteostasis , alfa-Sinucleína , alfa-Sinucleína/metabolismo , Animales , Enfermedad de Parkinson/metabolismo , Enfermedad de Parkinson/patología , Neuronas/metabolismo , Neuronas/patología , Ratones , Mapas de Interacción de Proteínas , Proteoma/metabolismo
13.
ACS Chem Biol ; 18(4): 942-948, 2023 04 21.
Artículo en Inglés | MEDLINE | ID: mdl-37043689

RESUMEN

Cellular pharmacodynamic assays are crucial aspects of lead optimization programs in drug discovery. These assays are sometimes difficult to develop, oftentimes distal from the target and frequently low throughput, which necessitates their incorporation in the drug discovery funnel later than desired. The earlier direct pharmacodynamic modulation of a target can be established, the fewer resources are wasted on compounds that are acting via an off-target mechanism. Mass spectrometry is a versatile tool that is often used for direct, proximal cellular pharmacodynamic assay analysis, but liquid chromatography-mass spectrometry methods are low throughput and are unable to fully support structure-activity relationship efforts in early medicinal chemistry programs. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is an ambient ionization method amenable to high-throughput cellular assays, capable of diverse analyte detection, ambient and rapid laser sampling processes, and low cross-contamination. Here, we demonstrate the capability of IR-MALDESI for the detection of diverse analytes directly from cells and report the development of a high-throughput, label-free, proximal cellular pharmacodynamic assay using IR-MALDESI for the discovery of glutaminase inhibitors and a biochemical assay for hit confirmation. We demonstrate the throughput with a ∼100,000-compound cellular screen. Hits from the screening were confirmed by retesting in dose-response with mass spectrometry-based cellular and biochemical assays. A similar workflow can be applied to other targets with minimal modifications, which will speed up the discovery of cell active lead series and minimize wasted chemistry resources on off-target mechanisms.


Asunto(s)
Glutaminasa , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Glutaminasa/antagonistas & inhibidores , Rayos Láser , Proteínas , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
14.
J Biol Chem ; 286(14): 12407-16, 2011 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-21266572

RESUMEN

Phospholipase C (PLC) enzymes are an important family of regulatory proteins involved in numerous cellular functions, primarily through hydrolysis of the polar head group from inositol-containing membrane phospholipids. U73122 (1-(6-((17ß-3-methoxyestra-1,3,5(10)-trien-17-yl)amino)hexyl)-1H-pyrrole-2,5-dione), one of only a few small molecules reported to inhibit the activity of these enzymes, has been broadly applied as a pharmacological tool to implicate PLCs in diverse experimental phenotypes. The purpose of this study was to develop a better understanding of molecular interactions between U73122 and PLCs. Hence, the effects of U73122 on human PLCß3 (hPLCß3) were evaluated in a cell-free micellar system. Surprisingly, U73122 increased the activity of hPLCß3 in a concentration- and time-dependent manner; up to an 8-fold increase in enzyme activity was observed with an EC50=13.6±5 µm. Activation of hPLCß3 by U73122 required covalent modification of cysteines as evidenced by the observation that enzyme activation was attenuated by thiol-containing nucleophiles, l-cysteine and glutathione. Mass spectrometric analysis confirmed covalent reaction with U73122 at eight cysteines, although maximum activation was achieved without complete alkylation; the modified residues were identified by LC/MS/MS peptide sequencing. Interestingly, U73122 (10 µm) also activated hPLCγ1 (>10-fold) and hPLCß2 (∼2-fold); PLCδ1 was neither activated nor inhibited. Therefore, in contrast to its reported inhibitory potential, U73122 failed to inhibit several purified PLCs. Most of these PLCs were directly activated by U73122, and a simple mechanism for the activation is proposed. These results strongly suggest a need to re-evaluate the use of U73122 as a general inhibitor of PLC isozymes.


Asunto(s)
Estrenos/farmacología , Inhibidores de Fosfodiesterasa/farmacología , Pirrolidinonas/farmacología , Fosfolipasas de Tipo C/metabolismo , Secuencia de Aminoácidos , Activación Enzimática/efectos de los fármacos , Estrenos/química , Humanos , Datos de Secuencia Molecular , Inhibidores de Fosfodiesterasa/química , Pirrolidinonas/química , Fosfolipasas de Tipo C/química
15.
J Mass Spectrom ; 57(6): e4869, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35678360

RESUMEN

Mass spectrometry (MS) is an effective analytical tool for high-throughput screening (HTS) in the drug discovery field. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) MS is a high-throughput platform that has achieved analysis times of sub-seconds-per-sample. Due to the high-throughput analysis speed, methods are needed to increase the analyte signal while decreasing the variability in IR-MALDESI-MS analyses to improve data quality and reduce false-positive hits. The Z-factor is used as a statistic of assay quality that can be improved by reducing the variation of target ion abundances or increasing signal. Herein we report optimal solvent compositions for increasing measured analyte abundances with direct analysis by IR-MALDESI-MS. We also evaluate normalization strategies, such as adding a normalization standard that is similar or dissimilar in structure to the model target drug, to reduce the variability of measured analyte abundances with direct analyses by IR-MALDESI-MS in both positive and negative ionization modes.


Asunto(s)
Ensayos Analíticos de Alto Rendimiento , Espectrometría de Masa por Ionización de Electrospray , Descubrimiento de Drogas , Rayos Láser , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
16.
J Am Soc Mass Spectrom ; 33(12): 2338-2341, 2022 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-36378849

RESUMEN

Deconvolution from intact protein mass-to-charge spectra to mass spectra is essential to generate interpretable data for mass spectrometry (MS) platforms coupled to ionization sources that produce multiply charged species. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) can be used to analyze intact proteins in multiwell microtiter plates with speed matching small molecule analyses (at least 1 Hz). However, the lack of compatible deconvolution software has limited its use in high-throughput screening applications. Most existing automated deconvolution software packages work best for data generated from LC-MS, and to the best of our knowledge, there is no software capable of performing fast plate-based mass spectral deconvolution. Herein we present the use of a new workflow in ProSight Native for the deconvolution of protein spectra from entire well plates that can be completed within 3 s. First, we successfully demonstrated the potential increased throughput benefits produced by the combined IR-MALDESI-MS - ProSight Native platform using protein standards. We then conducted a screen for Bruton's tyrosine kinase (BTK) covalent binders against a well-annotated compound collection consisting of 2232 compounds and applied ProSight Native to deconvolute the protein spectra. Seventeen hits including five known BTK covalent inhibitors in the compound set were identified. By alleviating the data processing bottleneck using ProSight Native, it may be feasible to analyze and report covalent screening results for >200,000 samples in a single day.


Asunto(s)
Espectrometría de Masas , Proteínas , Proteínas/química , Programas Informáticos
17.
J Am Soc Mass Spectrom ; 33(2): 328-334, 2022 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-35073091

RESUMEN

Infrared matrix-assisted laser desorption ionization (IR-MALDESI) is a hybrid mass spectrometry ionization source that combines the benefits of electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) making it a great analytical tool for high-throughput screening (HTS) analyses. IR-MALDESI is coupled to an Orbitrap Exploris 240 mass spectrometer that utilizes a bent quadrupole (C-trap) to inject accumulated ions into the high-field Orbitrap mass analyzer. Here, we present a study on the optimized C-trap timing for HTS analyses by IR-MALDESI mass spectrometry. The timing between initial ion generation and the C-trap opening time was optimized to reduce unnecessary ambient ion accumulation in the mass spectrometer. The time in which the C-trap was held open, the ion accumulation time, was further optimized to maximize the accumulation of analyte ions generated using IR-MALDESI. The resulting C-trap opening scheme benefits small-molecule HTS analyses by IR-MALDESI by maximizing target ion abundances, minimizing ambient ion abundances, and minimizing the total analysis time per sample. The proposed C-trap timing scheme for HTS does not translate to large molecules; a NIST monoclonal antibody standard reference material was analyzed to demonstrate that larger analytes require longer ion accumulation times and that IR-MALDESI can measure intact antibodies in their native state.

18.
J Am Soc Mass Spectrom ; 33(11): 2070-2077, 2022 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-36173393

RESUMEN

Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is a hybrid, ambient ionization source that combines the advantages of electrospray ionization and matrix-assisted laser desorption/ionization, making it a versatile tool for both high-throughput screening (HTS) and mass spectrometry imaging (MSI) studies. To expand the capabilities of the IR-MALDESI source, an entirely new architecture was designed to overcome the key limitations of the previous source. This next-generation (NextGen) IR-MALDESI source features a vertically mounted IR-laser, a planar translation stage with computerized sample height control, an aluminum enclosure, and a novel mass spectrometer interface plate. The NextGen IR-MALDESI source has improved user-friendliness, improved overall versatility, and can be coupled to numerous Orbitrap mass spectrometers to accommodate more research laboratories. In this work, we highlight the benefits of the NextGen IR-MALDESI source as an improved platform for MSI and direct analysis. We also optimize the NextGen MALDESI source component geometries to increase target ion abundances over a wide m/z range. Finally, documentation is provided for each NextGen IR-MALDESI part so that it can be replicated and incorporated into any lab space.


Asunto(s)
Ensayos Analíticos de Alto Rendimiento , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Rayos Láser
19.
Proc Natl Acad Sci U S A ; 105(8): 2773-8, 2008 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-18287036

RESUMEN

Analysis of the x-ray crystal structure of mono-substituted acetylenic thienopyrimidine 6 complexed with the ErbB family enzyme ErbB-4 revealed a covalent bond between the terminal carbon of the acetylene moiety and the sulfhydryl group of Cys-803 at the solvent interface. The identification of this covalent adduct suggested that acetylenic thienopyrimidine 6 and related analogs might also be capable of forming an analogous covalent adduct with EGFR, which has a conserved cysteine (797) near the ATP binding pocket. To test this hypothesis, we treated a truncated, catalytically competent form of EGFR (678-1020) with a structurally related propargylic amine (8). An investigation of the resulting complex by mass spectrometry revealed the formation of a covalent complex of thienopyrimidine 8 with Cys-797 of EGFR. This finding enabled us to readily assess the irreversibility of various inhibitors and also facilitated a structure-activity relationship understanding of the covalent modifying potential and biological activity of a series of acetylenic thienopyrimidine compounds with potent antitumor activity. Several ErbB family enzyme and cell potent 6-ethynyl thienopyrimidine kinase inhibitors were found to form covalent adducts with EGFR.


Asunto(s)
Alquinos/metabolismo , Compuestos de Anilina/metabolismo , Receptores ErbB/metabolismo , Modelos Moleculares , Pirimidinas/metabolismo , Animales , Proliferación Celular/efectos de los fármacos , Cristalografía por Rayos X , Relación Dosis-Respuesta a Droga , Femenino , Isatina/análogos & derivados , Isatina/metabolismo , Espectrometría de Masas , Ratones , Ratones SCID , Estructura Molecular , Pirimidinas/toxicidad , Proteínas Tirosina Quinasas Receptoras/metabolismo , Relación Estructura-Actividad , Ensayos Antitumor por Modelo de Xenoinjerto
20.
Mol Endocrinol ; 23(1): 25-34, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18988706

RESUMEN

Despite the fact that many nuclear receptors are ligand dependent, the existence of obligate regulatory ligands is debated for some receptors, including steroidogenic factor 1 (SF-1). Although fortuitously bound bacterial phospholipids were discovered in the structures of the SF-1 ligand-binding domain (LBD), these lipids might serve merely as structural ligands. Thus, we examined whether exogenously added phospholipids would exchange for these bacterial lipids and bind to SF-1. Here, we report the first crystal structure of the SF-1 LBD bound by the exchanged phosphatidylcholine. Although the bound phosphatidylcholine phospholipid mimics the conformation of bound bacterial phosphoplipids, two surface loops, L2-3 and L11-12, surrounding the entrance to the pocket vary significantly between different SF-1 LBD structures. Based on this observation, we hypothesized that a bound ligand might control the conformations of loops L2-3 and L11-12, and that conserved residues in these dynamic loops could influence ligand binding and the receptor function. Consistent with this hypothesis, impaired phospholipid exchange and diminished transcriptional activity were observed for loop L11-12 SF-1 mutants and for the loop L2-3 human mutant R255L. The endocrine disease associated with this L2-3 mutation coupled with our cellular and biochemical data suggest that critical residues at the mouth of the ligand-binding pocket have evolved for efficient binding of phospholipid ligands and for achieving optimal SF-1 activity.


Asunto(s)
Fosfolípidos/metabolismo , Factor Esteroidogénico 1/química , Factor Esteroidogénico 1/metabolismo , Secuencia de Aminoácidos , Sustitución de Aminoácidos , Animales , Secuencia de Bases , Sitios de Unión , Secuencia Conservada , Cristalografía por Rayos X , Cartilla de ADN/genética , Evolución Molecular , Humanos , Técnicas In Vitro , Lecitinas/química , Lecitinas/metabolismo , Ligandos , Ratones , Modelos Moleculares , Datos de Secuencia Molecular , Mutagénesis Sitio-Dirigida , Fosfolípidos/química , Conformación Proteica , Estructura Terciaria de Proteína , Homología de Secuencia de Aminoácido , Factor Esteroidogénico 1/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA