Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 22(11): 185-195, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34697869

RESUMEN

PURPOSE: Research productivity metrics are important for decisions regarding hiring, retention, and promotion in academic medicine, and these metrics can vary widely among different disciplines. This article examines productivity metrics for radiation therapy physicists (RTP) in the United States. METHODS AND MATERIALS: Database searches were performed for RTP faculty at US institutions that have RTP residencies accredited by the Commission on Accreditation of Medical Physics Education Programs (CAMPEP). Demographics, academic rank, number of publications, academic career length, Hirsch index (h-index), m-quotient, and history of National Institutes of Health (NIH) funding as a principal investigator (PI) were collected for each RTP. Logistic regression was performed to determine the probability of academic rank as a function of h-index and m-quotient. Statistical tests used included the Wilcoxon ranked sum test and the Pearson χ2 test. RESULTS: A total of 1038 faculty and staff were identified at 78 institutions with CAMPEP-accredited residencies. The average RTP academic career duration is 13.5 years, with 46.7 total publications, h-index of 10.7, and m-quotient of 0.66. Additionally, 10.5% of RTP have a history of NIH funding as a PI. Large disparities were found in academic productivity of doctoral-prepared physicists compared to those with a terminal master's degree. For differences in junior and senior faculty, statistical tests yielded significance in career duration, number of publications, h-index, and m-quotient. Gender disparities were identified in the overall distribution of RTP consistent with the membership of the American Association of Physicists in Medicine. Further gender disparities were found in the number of doctoral-prepared RTP and physicists in senior faculty roles. CONCLUSIONS: This manuscript provides objective benchmark data regarding research productivity of academic RTP. These data may be of interest to faculty preparing for promotion, and also to institutional leadership.


Asunto(s)
Investigación Biomédica , Internado y Residencia , Eficiencia , Docentes , Humanos , National Institutes of Health (U.S.) , Física , Estados Unidos
2.
J Appl Clin Med Phys ; 21(12): 178-187, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33226709

RESUMEN

PURPOSE: Real-time magnetic resonance guided radiation therapy (MRgRT) uses 2D cine imaging for target tracking. This work evaluates the percent image uniformity (PIU) and spatial integrity of cine images in the presence of multileaf collimator (MLC) and gantry motion in order to simulate sliding window and volumetric modulated arc therapy (VMAT) conditions. METHODS: Percent image uniformity and spatial integrity of cine images were measured (1) during MLC motion, (2) as a function of static gantry position, and (3) during gantry rotation. PIU was calculated according to the ACR MRI Quality Control Manual. Spatial integrity was evaluated by measuring the geometric distortion of 16 measured marker positions (10 cm or 15.225 cm from isocenter). RESULTS: The PIU of cine images did not vary by more than 1% from static linac conditions during MLC motion and did not vary by more than 3% during gantry rotation. Banding artifacts were present during gantry rotation. The geometric distortion in the cine images was less than 0.88 mm for all points measured throughout MLC motion. For all static gantry positions, the geometric distortion was less than 0.88 mm at 10 cm from isocenter and less than 1.4 mm at 15.225 cm from isocenter. During gantry rotation, the geometric distortion remained less than 0.92 mm at 10 cm from isocenter and less than 1.60 mm at 15.225 cm from isocenter. CONCLUSION: During MLC motion, cine images maintained adequate PIU, and the geometric distortion of points within 15.225 cm from isocenter was less than the 1 mm threshold necessary for real-time target tracking and gating. During gantry rotation, PIU was negatively affected by banding artifacts, and spatial integrity was only maintained within 10 cm from isocenter. Future work should investigate the effects imaging artifacts have on real-time target tracking during MRgRT.


Asunto(s)
Aceleradores de Partículas , Radioterapia de Intensidad Modulada , Humanos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Control de Calidad
3.
J Appl Clin Med Phys ; 19(3): 261-267, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29624212

RESUMEN

PURPOSE: The purpose of this study was to investigate daily repositioning accuracy by analyzing inter- and intra-fractional uncertainties associated with patients treated for intracranial or base of skull tumors in a compact proton therapy system with 6 degrees of freedom (DOF) robotic couch and a thermoplastic head mask indexed to a base of skull (BoS) frame. MATERIALS AND METHODS: Daily orthogonal kV alignment images at setup position before and after daily treatments were analyzed for 33 patients. The system was composed of a new type of thermoplastic mask, a bite block, and carbon-fiber BoS couch-top insert specifically designed for proton therapy treatments. The correctional shifts in robotic treatment table with 6 DOF were evaluated and recorded based on over 1500 planar kV image pairs. Correctional shifts for patients with and without bite blocks were compared. RESULTS: Systematic and random errors were evaluated for all 6 DOF coordinates available for daily vector corrections. Uncertainties associated with geometrical errors and their sources, in addition to robustness analysis of various combinations of immobilization components were presented. CONCLUSIONS: Analysis of 644 fractions including patients with and without a bite block shows that the BoS immobilization system is capable of maintaining intra-fraction localization with submillimeter accuracy (in nearly 83%, 86%, 95% of cases along SI, LAT, and PA, respectively) in translational coordinates and subdegree precision (in 98.85%, 98.85%, and 96.4% of cases for roll, pitch, and yaw respectively) in rotational coordinates. The system overall fares better in intra-fraction localization precision compared to previously reported particle therapy immobilization systems. The use of a mask-attached type bite block has marginal impact on inter- or intra-fraction uncertainties compared to no bite block.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Inmovilización/métodos , Posicionamiento del Paciente , Fantasmas de Imagen , Terapia de Protones , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias de la Base del Cráneo/radioterapia , Neoplasias Encefálicas/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Humanos , Órganos en Riesgo/efectos de la radiación , Pronóstico , Radiometría/métodos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Neoplasias de la Base del Cráneo/diagnóstico por imagen
4.
J Appl Clin Med Phys ; 19(3): 149-158, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29682879

RESUMEN

PURPOSE: To describe the commissioning of AIRO mobile CT system (AIRO) for adaptive proton therapy on a compact double scattering proton therapy system. METHODS: A Gammex phantom was scanned with varying plug patterns, table heights, and mAs on a CT simulator (CT Sim) and on the AIRO. AIRO-specific CT-stopping power ratio (SPR) curves were created with a commonly used stoichiometric method using the Gammex phantom. A RANDO anthropomorphic thorax, pelvis, and head phantom, and a CIRS thorax and head phantom were scanned on the CT Sim and AIRO. Clinically realistic treatment plans and nonclinical plans were generated on the CT Sim images and subsequently copied onto the AIRO CT scans for dose recalculation and comparison for various AIRO SPR curves. Gamma analysis was used to evaluate dosimetric deviation between both plans. RESULTS: AIRO CT values skewed toward solid water when plugs were scanned surrounded by other plugs in phantom. Low-density materials demonstrated largest differences. Dose calculated on AIRO CT scans with stoichiometric-based SPR curves produced over-ranged proton beams when large volumes of low-density material were in the path of the beam. To create equivalent dose distributions on both data sets, the AIRO SPR curve's low-density data points were iteratively adjusted to yield better proton beam range agreement based on isodose lines. Comparison of the stoichiometric-based AIRO SPR curve and the "dose-adjusted" SPR curve showed slight improvement on gamma analysis between the treatment plan and the AIRO plan for single-field plans at the 1%, 1 mm level, but did not affect clinical plans indicating that HU number differences between the CT Sim and AIRO did not affect dose calculations for robust clinical beam arrangements. CONCLUSION: Based on this study, we believe the AIRO can be used offline for adaptive proton therapy on a compact double scattering proton therapy system.


Asunto(s)
Algoritmos , Cabeza/diagnóstico por imagen , Fantasmas de Imagen , Terapia de Protones , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/instrumentación , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Tomografía Computarizada por Rayos X/métodos
5.
J Appl Clin Med Phys ; 18(3): 130-136, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28436155

RESUMEN

PURPOSE: The purpose of this study was to characterize the Mobius AIRO Mobile CT System for localization and image-guided proton therapy. This is the first known application of the AIRO for proton therapy. METHODS: Five CT images of a Catphan® 504 phantom were acquired on the AIRO Mobile CT System, Varian EDGE radiosurgery system cone beam CT (CBCT), Philips Brilliance Big Bore 16 slice CT simulator, and Siemens SOMATOM Definition AS 20 slice CT simulator. DoseLAB software v.6.6 was utilized for image quality analysis. Modulation transfer function, scaling discrepancy, geometric distortion, spatial resolution, overall uniformity, minimum uniformity, contrast, high CNR, and maximum HU deviation were acquired. Low CNR was acquired manually using the CTP515 module. Localization accuracy and CT Dose Index were measured and compared to reported values on each imaging device. For treatment delivery systems (Edge and Mevion), the localization accuracy of the 3D imaging systems were compared to 2D imaging systems on each system. RESULTS: The AIRO spatial resolution was 0.21 lp mm-1 compared with 0.40 lp mm-1 for the Philips CT Simulator, 0.37 lp mm-1 for the Edge CBCT, and 0.35 lp mm-1 for the Siemens CT Simulator. AIRO/Siemens and AIRO/Philips differences exceeded 100% for scaling discrepancy (191.2% and 145.8%). The AIRO exhibited higher dose (>27 mGy) than the Philips CT Simulator. Localization accuracy (based on the MIMI phantom) was 0.6° and 0.5 mm. Localization accuracy (based on Stereophan) demonstrated maximum AIRO-kV/kV shift differences of 0.1 mm in the x-direction, 0.1 mm in the y-direction, and 0.2 mm in the z-direction. CONCLUSIONS: The localization accuracy of AIRO was determined to be within 0.6° and 0.5 mm despite its slightly lower image quality overall compared to other CT imaging systems at our institution. Based on our study, the Mobile AIRO CT system can be utilized accurately and reliably for image-guided proton therapy.


Asunto(s)
Terapia de Protones/instrumentación , Radiocirugia/instrumentación , Radioterapia Guiada por Imagen/instrumentación , Tomografía Computarizada por Rayos X , Tomografía Computarizada de Haz Cónico , Diseño de Equipo , Humanos , Fantasmas de Imagen , Terapia de Protones/métodos , Radiocirugia/métodos , Radioterapia Guiada por Imagen/métodos
6.
Int J Part Ther ; 13: 100112, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39105198

RESUMEN

This case study explores the strategic decision-making and safety considerations in managing a unique scenario where a pacemaker dependent patient, requiring adjuvant radiotherapy for bilateral breast cancer. The conventional pacemaker was located entirely within the treatment target, without the option for transposition because of the bilateral chest treatment, resulting in significant risk of malfunction caused by exposing it to the full prescribed dose. Consequently, the decision was made to replace the conventional pacemaker with a leadless device Micra implanted directly into the heart to mitigate direct device radiation and potential adverse effects of proton therapy on the cardiac device. Following Micra implantation, the patient underwent the proton treatment without complications or serious device malfunctions. This study explores solutions to address the challenges posed by within-the-field cardiac devices and highlights the use of pencil beam proton therapy for individuals with leadless cardiac devices while acknowledging the potential for neutron production and the associated risk of single-event upsets (SEU) in cardiac implantable electronic devices (CIEDs). The findings underscore the significance of strategic decision-making, risk assessment, and continuous monitoring for successful outcomes, particularly in the context of proton therapy for patients with advanced cardiac considerations.

7.
Med Phys ; 39(4): 1728-47, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22482598

RESUMEN

New technologies continue to be developed to improve the practice of radiation therapy. As several of these technologies have been implemented clinically, the Therapy Committee and the Quality Assurance and Outcomes Improvement Subcommittee of the American Association of Physicists in Medicine commissioned Task Group 147 to review the current nonradiographic technologies used for localization and tracking in radiotherapy. The specific charge of this task group was to make recommendations about the use of nonradiographic methods of localization, specifically; radiofrequency, infrared, laser, and video based patient localization and monitoring systems. The charge of this task group was to review the current use of these technologies and to write quality assurance guidelines for the use of these technologies in the clinical setting. Recommendations include testing of equipment for initial installation as well as ongoing quality assurance. As the equipment included in this task group continues to evolve, both in the type and sophistication of technology and in level of integration with treatment devices, some of the details of how one would conduct such testing will also continue to evolve. This task group, therefore, is focused on providing recommendations on the use of this equipment rather than on the equipment itself, and should be adaptable to each user's situation in helping develop a comprehensive quality assurance program.


Asunto(s)
Posicionamiento del Paciente/normas , Guías de Práctica Clínica como Asunto , Garantía de la Calidad de Atención de Salud/normas , Radioterapia Conformacional/normas , Radioterapia Guiada por Imagen/normas
8.
Int J Part Ther ; 9(1): 54-63, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35774494

RESUMEN

Purpose: To present quantitative dosimetric evaluations of five proton pencil beam spot placement techniques. Materials and Methods: The spot placement techniques that were investigated include two grid-based (rectilinear grid and hexagonal grid, both commonly available in commercial planning systems) and three boundary-contoured (concentric contours, hybrid, and optimized) techniques. Treatment plans were created for two different target volumes, one spherical and one conical. An optimal set of planning parameters was defined for all treatment plans and the impact of spot placement techniques on the plan quality was evaluated in terms of lateral/distal dose falloff, normal tissue sparing, conformity and homogeneity of dose distributions, as well as total number of spots used. Results: The results of this work highlight that for grid-based spot placement techniques, the dose conformity is dependent on target cross-sectional shape perpendicular to beam direction, which changes for each energy layer. This variable conformity problem is mitigated by using boundary contoured spot placement techniques. However, in the case of concentric contours, the conformity is improved but at the cost of decreased homogeneity inside the target. Hybrid and optimized spot placement techniques, which use contoured spots at the boundary and gridlike interior spot patterns, provide more uniform dose distributions inside the target volume while maintaining the improved dose conformity. The optimized spot placement technique improved target coverage, homogeneity of dose, and minimal number of spots. The dependence of these results on spot size is also presented for both target shapes. Conclusion: This work illustrates that boundary-contoured spot placement techniques offer marked improvement in dosimetry metrics when compared to commercially available grid-based techniques for a range of proton scanned beam spot sizes.

9.
Int J Part Ther ; 9(2): 10-19, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36060418

RESUMEN

Purpose: We present an analysis of various operational metrics for a novel compact proton therapy system, including clinical case mix, subsystems utilization, and quality assurance trends in beam delivery parameters over a period of 5 years. Materials and Methods: Patient-specific data from a total of 850 patients (25,567 fractions) have been collected and analyzed. The patient mix include a variety of simple, intermediate, and complex cases. Beam-specific delivery parameters for a total of 3585 beams were analyzed. In-room imaging system usage for off-line adaptive purpose is reported. We also report key machine performances metrics based on routine quality assurance in addition to uptime. Results: Our analysis shows that system subcomponents including gantry and patient positioning system have maintained a tight mechanical tolerance over the 5-year period. Various beam parameters were all within acceptable tolerances with no clear trends. Utilization frequency histograms of gantry and patient positioning system show that only a small fraction of all available angles was used for patient deliveries with cardinal angels as the most usable. Similarly, beam-specific metrics, such as range, modulation, and air gaps, were clustered unevenly over the available range indicating that this compact system was more than capable to treat the complex variety of tumors of our patient mix. Conclusion: Our data show that this compact system is versatile, robust, and capable of delivering complex treatments like a large full-gantry system. Utilization data show that a fraction of all subcomponents range of angular motion has been used. Compilation of beam-specific metrics, such as range and modulation, show uneven distributions with specific clustering over the entire usable range. Our findings could be used to further optimize the performance and cost-effectiveness of future compact proton systems.

10.
J Appl Clin Med Phys ; 12(4): 3590, 2011 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-22089017

RESUMEN

In the past 10 years, techniques to improve radiotherapy delivery, such as intensity-modulated radiation therapy (IMRT), image-guided radiation therapy (IGRT) for both inter- and intrafraction tumor localization, and hypofractionated delivery techniques such as stereotactic body radiation therapy (SBRT), have evolved tremendously. This review article focuses on only one part of that evolution, electromagnetic tracking in radiation therapy. Electromagnetic tracking is still a growing technology in radiation oncology and, as such, the clinical applications are limited, the expense is high, and the reimbursement is insufficient to cover these costs. At the same time, current experience with electromagnetic tracking applied to various clinical tumor sites indicates that the potential benefits of electromagnetic tracking could be significant for patients receiving radiation therapy. Daily use of these tracking systems is minimally invasive and delivers no additional ionizing radiation to the patient, and these systems can provide explicit tumor motion data. Although there are a number of technical and fiscal issues that need to be addressed, electromagnetic tracking systems are expected to play a continued role in improving the precision of radiation delivery.


Asunto(s)
Neoplasias/radioterapia , Radioterapia de Intensidad Modulada/métodos , Fenómenos Electromagnéticos , Humanos
11.
J Appl Clin Med Phys ; 12(1): 3311, 2010 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-21330977

RESUMEN

We report on our initial experience with daily image guidance for the treatment of a patient with a basal cell carcinoma of the nasal dorsum using bolus electron conformal therapy. We describe our approach to daily alignment using treatment machine-integrated megavoltage (MV) planar imaging in conjunction with cone beam CT (CBCT) volumetric imaging to ensure the best possible setup reproducibility. Based on MV imaging, beam aperture misalignment with the intended treatment region was as large as 0.5 cm in the coronal plane. Four of the five fractions analyzed show induced shifts when compared to digitally reconstructed radiographs (DRR), in the range of 0.2-0.5 cm. Daily inspection of CBCT images show that the bolus device can have significant tilt in any given direction by as much as 13° with respect to beam axis. In addition, we show that CBCT images reveal air gaps between bolus and skin that vary from day to day, and can potentially degrade surface dose coverage. Retrospective dose calculation on CBCT image sets shows that when daily shifts based on MV imaging are not corrected, geometrical miss of the planning target volume (PTV) can cause an underdosing as large as 14% based on DVH analysis of the dose to the 90% of the PTV volume.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Neoplasias Nasales/radioterapia , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Conformacional/métodos , Algoritmos , Electrones/uso terapéutico , Humanos , Dosificación Radioterapéutica
12.
J Appl Clin Med Phys ; 11(1): 2924, 2010 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-20160686

RESUMEN

The aim of this study is to compare two methodologies of prostate localization in a large cohort of patients. Daily prostate localization using B-mode ultrasound has been performed at the Nebraska Medical Center since 2000. More recently, a technology using electromagnetic transponders implanted within the prostate was introduced into our clinic (Calypso(R)). With each technology, patients were localized initially using skin marks. Localization error distributions were determined from offsets between the initial setup positions and those determined by ultrasound or Calypso. Ultrasound localization data was summarized from 16619 imaging sessions spanning 7 years; Calypso localization data consists of 1524 fractions in 41 prostate patients treated in the course of a clinical trial at five institutions and 640 localizations from the first 16 patients treated with our clinical system. Ultrasound and Calypso patients treated between March and September 2007 at the Nebraska Medical Center were analyzed and compared, allowing a single institutional comparison of the two technologies. In this group of patients, the isocenter determined by ultrasound-based localization is on average 5.3 mm posterior to that determined by Calypso, while the systematic and random errors and PTV margins calculated from the ultrasound localizations were 3 - 4 times smaller than those calculated from the Calypso localizations. Our study finds that there are systematic differences between Calypso and ultrasound for prostate localization.


Asunto(s)
Fenómenos Electromagnéticos , Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Ultrasonografía , Abdomen , Humanos , Funciones de Verosimilitud , Masculino , Movimiento , Nebraska , Próstata/patología , Neoplasias de la Próstata/diagnóstico , Prótesis e Implantes , Radiografía , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Piel , Factores de Tiempo
13.
J Radiosurg SBRT ; 7(2): 149-156, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33282468

RESUMEN

Commercial systems such as Varian HyperArcTM and BrainLab Elements MultiMetTM have been developed that allow radiosurgery treatment of multiple brain metastases using a single isocenter. Each software package places increased demands on frameless immobilization and requires the use of a specific immobilization system: the QFix-Encompass system for Varian and the BrainLab frameless-mask system for BrainLab. At our institution, patients receiving traditional radiosurgery (one isocenter per target lesion) were treated using both immobilization systems. Intrafraction motion was determined for each patient using multiple cone-beam CT scans and the same image-registration software during treatment. There were no statistically-significant differences in mean absolute translational shifts between the two mask systems, with a mean 3D-vector motion of approximately 0.43 mm for both systems. There were also no statistically-significant differences in the mean absolute rotational shifts between the two mask systems. Although the average residual errors were insignificant between the mask systems, special attention should be paid to individual maximum shifts with both systems. Large maximum rotational misalignments could present significant misalignment of lesions as distance increases from the isocenter. Finally, large maximum shifts highlight the need for real-time monitoring of patient movement during radiosurgery of multiple lesions using a single isocenter.

14.
Pract Radiat Oncol ; 10(5): e425-e431, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32004703

RESUMEN

PURPOSE: Treating critically ill patients in radiation oncology departments poses multiple safety risks. This study describes a method to improve the speed of radiation treatment for patients in the intensive care unit by eliminating the need for computed tomography (CT) simulation or on-table treatment planning using patients' previously acquired diagnostic CT scans. METHODS AND MATERIALS: Initially, a retrospective planning study was performed to assess the applicability and safety of diagnostic scan-based planning (DSBP) for 3 typical indications for radiation therapy in patients in the intensive care unit: heterotopic ossification (10), spine metastases (cord compression; 10), and obstructive lung lesions (5). After identification of an appropriate diagnostic CT scan, treatment planning was performed using the diagnostic scan data set. These treatment plans were then transferred to the patients' simulation scans, and a dosimetric comparison was performed between the 2 sets of plans. Additionally, a time study of the first 10 patients treated with DSBP in our department was performed. RESULTS: The retrospective analysis demonstrated that DSBP resulted in treatment plans that, when transferred to the CT simulation data sets, provided excellent target coverage, a median D95% of 96% (range, 86%-100%) of the prescription dose with acceptable hot spots, and a median Dmax108% (range, 102%-113%). Subsequently, DSBP has been used for 10 critically ill patients. The patients were treated without CT simulation, and the median time between patient check-in to the department and completion of radiation therapy was 28 minutes (range, 18-47 minutes.) CONCLUSIONS: This study demonstrates that it is possible to safely use DSBP for the treatment of critically ill patients. This method has the potential to simplify the treatment process and improve the speed and safety of treatment.


Asunto(s)
Enfermedad Crítica , Humanos , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
15.
Med Phys ; 36(8): 3477-86, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19746781

RESUMEN

The Calypso Medical 4D localization system utilizes alternating current electromagnetics for accurate, real-time tumor tracking. A quality assurance program to clinically implement this system is described here. Testing of the continuous electromagnetic tracking system (Calypso Medical Technologies, Seattle, WA) was performed using an in-house developed four-dimensional stage and a quality assurance fixture containing three radiofrequency transponders at independently measured locations. The following tests were performed to validate the Calypso system: (a) Localization and tracking accuracy, (b) system reproducibility, (c) measurement of the latency of the tracking system, and (d) measurement of transmission through the Calypso table overlay and the electromagnetic array. The translational and rotational localization accuracies were found to be within 0.01 cm and 1.0 degree, respectively. The reproducibility was within 0.1 cm. The average system latency was measured to be within 303 ms. The attenuation by the Calypso overlay was measured to be 1.0% for both 6 and 18 MV photons. The attenuations by the Calypso array were measured to be 2% and 1.5% for 6 and 18 MV photons, respectively. For oblique angles, the transmission was measured to be 3% for 6 MV, while it was 2% for 18 MV photons. A quality assurance process has been developed for the clinical implementation of an electromagnetic tracking system in radiation therapy.


Asunto(s)
Fenómenos Electromagnéticos , Radioterapia/instrumentación , Radioterapia/normas , Seguridad de Equipos , Humanos , Procesamiento de Imagen Asistido por Computador , Modelos Lineales , Movimiento (Física) , Control de Calidad , Reproducibilidad de los Resultados
16.
Technol Cancer Res Treat ; 8(2): 123-30, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19334793

RESUMEN

Initial results of megavoltage computed tomography (MVCT) brachytherapy treatment planning are presented, using a commercially available helical tomotherapy treatment unit and standard low dose rate (LDR) brachytherapy applicators used for treatment of cervical carcinoma. The accuracy of MVCT imaging techniques, and dosimetric accuracy of the CT based plans were tested with in-house and commercially-available phantoms. Three dimensional (3D) dose distributions were computed and compared to the two dimensional (2D) dosimetry results. Minimal doses received by the 2 cm3 of bladder and rectum receiving the highest doses (D(B2cc) and D(R2cc), respectively) were computed from dose-volume histograms and compared to the doses computed for the standard ICRU bladder and rectal reference dose points. Phantom test objects in MVCT image sets were localized with sub-millimetric accuracy, and the accuracy of the MVCT-based dose calculation was verified. Fifteen brachytherapy insertions were also analyzed. The ICRU rectal point dose did not differ significantly from D(R2cc) (p=0.749, mean difference was 24 cGy +/- 283 cGy). The ICRU bladder point dose was significantly lower than the D(B2cc) (p=0.024, mean difference was 291 cGy +/- 444 cGy). The median volumes of bladder and rectum receiving at least the corresponding ICRU reference point dose were 6.1 cm(3) and 2.0 cm(3), respectively. Our initial experience in using MVCT imaging for clinical LDR gynecological brachytherapy indicates that the MVCT images are of sufficient quality for use in 3D, MVCT-based dose planning.


Asunto(s)
Braquiterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X , Neoplasias del Cuello Uterino/radioterapia , Femenino , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/instrumentación , Recto/efectos de la radiación , Vejiga Urinaria/efectos de la radiación
17.
Phys Med Biol ; 64(23): 235016, 2019 12 05.
Artículo en Inglés | MEDLINE | ID: mdl-31618722

RESUMEN

Maintaining a sharp lateral dose falloff in pencil beam scanning (PBS) proton therapy is crucial for sparing organs at risk (OARs), especially when they are in close proximity to the target volume. The most common approach to improve lateral dose falloff is through the use of physical beam shaping devices, such as brass apertures or collimator based systems. A recently proposed approach focuses on proton beam spot placements, moving away from traditional grid-based placements to concentric-contours based schemes. This improves lateral dose falloff in two ways: (1) by better conforming all spots to the tumor boundary and (2) allowing for 'edge enhancement', where boundary spots deliver higher fluence than more central spots, thereby creating a steeper lateral dose falloff. However, these benefits come at the expense of maintaining uniformity of spot distribution inside the target volume. In this work we have developed a new optimized spot placement scheme that provides robust spot distributions inside the target. This approach achieves the boundary conformity of a concentric-contours based approach and uses a fast-iterative method to distribute the interior spots in a highly uniform fashion in an attempt to improve both the lateral dose falloff and uniformity. Furthermore, we quantified the impact of this new approach through direct comparison with grid, contour, and hybrid spot placements schemes, showing improvements for this new approach. The results were validated in homogeneous medium for two different target shapes having concave and convex geometry.


Asunto(s)
Terapia de Protones/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Neoplasias/radioterapia , Órganos en Riesgo , Dosificación Radioterapéutica
18.
Semin Radiat Oncol ; 18(1): 58-66, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18082589

RESUMEN

Prostate motion during external-beam radiotherapy can affect outcomes in patients with localized prostate cancer. Prostate motion and deformation are currently being characterized with different techniques. There is significant individual variation among patients with respect to the observed motion and its dosimetric consequences. There is also significant difference in the accuracy of different localization methods currently used to adjust for prostate motion. The motion of the prostate gland can itself affect the accuracy of different localization methods. The dosimetric impact on target areas and organs at risk should be studied for different localization techniques, treatment plan margins, and treatment schedules. Such assessments will be increasingly important with smaller treatment margins, smaller fraction numbers, and higher radiation doses. Understanding and managing the consequences of anatomic variations within the lower pelvis should be a priority in designing and implementing future clinical trials.


Asunto(s)
Neoplasias de la Próstata/radioterapia , Radioterapia/métodos , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Dosificación Radioterapéutica , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Ultrasonografía
19.
Int J Radiat Oncol Biol Phys ; 70(4): 1146-50, 2008 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-17919834

RESUMEN

PURPOSE: To verify whether rectal distention at the time of planning impacts outcomes in patients with localized prostate cancer treated with daily image guidance. METHODS AND MATERIALS: Between 1998 and 2002, a total of 488 prostate cancer patients were treated with intensity-modulated radiotherapy. The radiation dose was 70 Gy delivered at 2.5 Gy per fraction in all cases. All cases were treated with a 4-mm margin posteriorly. In all cases the total rectal volume documented on the CT scan was used for treatment planning. No special bowel preparation instructions were given, either for the simulation or the daily treatments. Before each daily treatment, alignment of the prostate was performed with the B-mode acquisition and targeting (BAT) transabdominal ultrasound system. The median follow-up for all 488 patients was 60 months (range, 24-96 months). RESULTS: For all patients the biochemical relapse-free survival (bRFS) rate at 5 years was 86%. The 5-year bRFS rate for the rectal distention<50 cm3, 50 to <100 cm3, and >or=100 cm3 groups was 90%, 83%, and 85%, respectively (p=0.18). To adjust for other potential variables affecting bRFS rates, a multivariate time-to-failure analysis using the Cox proportional hazards model was performed. Rectal distention was not an independent predictor of biochemical failure on multivariate analysis (p=0.80). Rectal distention was not a predictor of rectal or urinary toxicity. CONCLUSION: The use of daily image guidance eliminates errors such as rectal distention at the initial planning stage that can affect outcomes after radiotherapy for localized prostate cancer.


Asunto(s)
Neoplasias de la Próstata/radioterapia , Radioterapia de Intensidad Modulada , Recto/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Supervivencia sin Enfermedad , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Próstata/diagnóstico por imagen , Próstata/patología , Antígeno Prostático Específico/sangre , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Recto/anatomía & histología , Recto/efectos de la radiación , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Ultrasonografía , Vejiga Urinaria/efectos de la radiación
20.
Int J Radiat Oncol Biol Phys ; 71(4): 1084-90, 2008 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-18280057

RESUMEN

PURPOSE: To quantify and describe the real-time movement of the prostate gland in a large data set of patients treated with radiotherapy. METHODS AND MATERIALS: The Calypso four-dimensional localization system was used for target localization in 17 patients, with electromagnetic markers implanted in the prostate of each patient. We analyzed a total of 550 continuous tracking sessions. The fraction of time that the prostate was displaced by >3, >5, >7, and >10 mm was calculated for each session and patient. The frequencies of displacements after initial patient positioning were analyzed over time. RESULTS: Averaged over all patients, the prostate was displaced >3 and >5 mm for 13.6% and 3.3% of the total treatment time, respectively. For individual patients, the corresponding maximal values were 36.2% and 10.9%. For individual fractions, the corresponding maximal values were 98.7% and 98.6%. Displacements >3 mm were observed at 5 min after initial alignment in about one-eighth of the observations, and increased to one-quarter by 10 min. For individual patients, the maximal value of the displacements >3 mm at 5 and 10 min after initial positioning was 43% and 75%, respectively. CONCLUSION: On average, the prostate was displaced by >3 mm and >5 mm approximately 14% and 3% of the time, respectively. For individual patients, these values were up to three times greater. After the initial positioning, the likelihood of displacement of the prostate gland increased with elapsed time. This highlights the importance of initiating treatment shortly after initially positioning the patient.


Asunto(s)
Neoplasias de la Próstata/diagnóstico , Neoplasias de la Próstata/radioterapia , Radioterapia Asistida por Computador/métodos , Sistemas de Computación , Fenómenos Electromagnéticos , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA