Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Magn Reson Imaging ; 2024 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-38265188

RESUMEN

Ever since its introduction as a diagnostic imaging tool the potential of magnetic resonance imaging (MRI) in radiation therapy (RT) treatment simulation and planning has been recognized. Recent technical advances have addressed many of the impediments to use of this technology and as a result have resulted in rapid and growing adoption of MRI in RT. The purpose of this article is to provide a broad review of the multiple uses of MR in the RT treatment simulation and planning process, identify several of the most used clinical scenarios in which MR is integral to the simulation and planning process, highlight existing limitations and provide multiple unmet needs thereby highlighting opportunities for the diagnostic MR imaging community to contribute and collaborate with our oncology colleagues. EVIDENCE LEVEL: 5 TECHNICAL EFFICACY: Stage 5.

2.
Epilepsy Behav ; 148: 109472, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37866249

RESUMEN

PURPOSE: This study sought to evaluate the impact of surgical extent on seizure outcome in drug-resistant temporal lobe epilepsy (DR-TLE) with temporal encephaloceles (TE). METHODS: This was a single-institution retrospective study of patients who underwent surgery for DR-TLE with TE between January 2008 and December 2020. The impact of surgical extent on seizure outcome was evaluated. In a subset with dominant DR-TLE, the impact of surgical extent on neuropsychometric outcome was evaluated. RESULTS: Thirty-four patients were identified (female, 56%; median age at surgery, 43 years). TE were frequently overlooked on initial magnetic resonance imaging (MRI), with encephaloceles only detected after repeat or expert re-review of MRI, additional multi-modal imaging, or intra-operatively in 31 (91%). Sixteen (47%) underwent limited resections, including encephalocele resection only (n = 5) and encephalocele resection with more extensive temporal corticectomy sparing the amygdala and hippocampus (n = 11). The remainder (n = 18, 53%) underwent standard anterior temporal lobectomy and amygdalohippocampectomy (ATLAH). Limited resection was performed more frequently on the left (12/17 vs. 4/17, p = 0.015). Twenty-seven patients (79%) had a favourable outcome (Engel I/II), and 17 (50%) were seizure-free at the last follow-up (median seizure-free survival of 27.3 months). There was no statistically significant difference in seizure-free outcomes between limited resection and ATLAH. In dominant DR-TLE, verbal memory decline was more likely after ATLAH than limited resection (3/4 vs. 0/9, p = 0.014). CONCLUSION: Expert re-review of imaging and multi-modal advanced imaging improved TE identification. There was no statistical difference in seizure-free outcomes based on surgical extent. Preservation of verbal memory supports limited resection in dominant temporal cases.


Asunto(s)
Epilepsia Refractaria , Epilepsia del Lóbulo Temporal , Humanos , Femenino , Adulto , Epilepsia del Lóbulo Temporal/complicaciones , Epilepsia del Lóbulo Temporal/diagnóstico por imagen , Epilepsia del Lóbulo Temporal/cirugía , Encefalocele/complicaciones , Encefalocele/diagnóstico por imagen , Encefalocele/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Convulsiones/cirugía , Lobectomía Temporal Anterior/métodos , Epilepsia Refractaria/diagnóstico por imagen , Epilepsia Refractaria/cirugía , Hipocampo/diagnóstico por imagen , Hipocampo/cirugía , Imagen por Resonancia Magnética
3.
Neuroradiology ; 63(3): 439-445, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33025042

RESUMEN

PURPOSE: We investigated the hypothesis that increasing fMRI temporal resolution using a multiband (MB) gradient echo-echo planar imaging (GRE-EPI) pulse sequence provides fMRI language maps of higher statistical quality than those acquired with a traditional GRE-EPI sequence. METHODS: This prospective study enrolled 29 consecutive patients receiving language fMRI prior to a potential brain resection for tumor, AVM, or epilepsy. A 4-min rhyming task was performed at 3.0 Tesla with a traditional GRE-EPI pulse sequence (TR = 2000, TE = 30, matrix = 64/100%, slice = 4/0, FOV = 24, slices = 30, time points = 120) and an additional MB GRE-EPI pulse sequence with an acceleration factor of 6 (TR = 333, TE = 30, matrix 64/100%, slice = 4/0, FOV = 24, time points = 720). Spatially filtered t statistical maps were generated. Volumes of interest (VOIs) were drawn around activations at Broca's, dorsolateral prefrontal cortex, Wernicke's, and the visual word form areas. The t value maxima were measured for the overall brain and each of the VOIs. A paired t test was performed for the corresponding traditional and MB GRE-EPI measurements. RESULTS: The mean age of subjects was 42.6 years old (18-75). Sixty-two percent were male. The average overall brain t statistic maxima for the MB pulse sequence (t = 15.4) was higher than for the traditional pulse sequence (t = 9.3, p = < .0001). This also held true for Broca's area (p < 0.0001), Wernicke's area (p < .0001), dorsolateral prefrontal cortex (p < .0001), and the visual word form area (p < .0001). CONCLUSION: A MB GRE-EPI fMRI pulse sequence employing high temporal resolution provides clinical fMRI language maps of greater statistical significance than those obtained with a traditional GRE-EPI sequence.


Asunto(s)
Lenguaje , Imagen por Resonancia Magnética , Adulto , Mapeo Encefálico , Imagen Eco-Planar , Humanos , Masculino , Estudios Prospectivos
4.
MAGMA ; 34(5): 697-706, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33945050

RESUMEN

PURPOSE: MR fingerprinting (MRF) is a MR technique that allows assessment of tissue relaxation times. The purpose of this study is to evaluate the clinical application of this technique in patients with meningioma. MATERIALS AND METHODS: A whole-brain 3D isotropic 1mm3 acquisition under a 3.0T field strength was used to obtain MRF T1 and T2-based relaxometry values in 4:38 s. The accuracy of values was quantified by scanning a quantitative MR relaxometry phantom. In vivo evaluation was performed by applying the sequence to 20 subjects with 25 meningiomas. Regions of interest included the meningioma, caudate head, centrum semiovale, contralateral white matter and thalamus. For both phantom and subjects, mean values of both T1 and T2 estimates were obtained. Statistical significance of differences in mean values between the meningioma and other brain structures was tested using a Friedman's ANOVA test. RESULTS: MR fingerprinting phantom data demonstrated a linear relationship between measured and reference relaxometry estimates for both T1 (r2 = 0.99) and T2 (r2 = 0.97). MRF T1 relaxation times were longer in meningioma (mean ± SD 1429 ± 202 ms) compared to thalamus (mean ± SD 1054 ± 58 ms; p = 0.004), centrum semiovale (mean ± SD 825 ± 42 ms; p < 0.001) and contralateral white matter (mean ± SD 799 ± 40 ms; p < 0.001). MRF T2 relaxation times were longer for meningioma (mean ± SD 69 ± 27 ms) as compared to thalamus (mean ± SD 27 ± 3 ms; p < 0.001), caudate head (mean ± SD 39 ± 5 ms; p < 0.001) and contralateral white matter (mean ± SD 35 ± 4 ms; p < 0.001) CONCLUSIONS: Phantom measurements indicate that the proposed 3D-MRF sequence relaxometry estimations are valid and reproducible. For in vivo, entire brain coverage was obtained in clinically feasible time and allows quantitative assessment of meningioma in clinical practice.


Asunto(s)
Neoplasias Meníngeas , Meningioma , Encéfalo/diagnóstico por imagen , Estudios de Factibilidad , Humanos , Imagen por Resonancia Magnética , Neoplasias Meníngeas/diagnóstico por imagen , Meningioma/diagnóstico por imagen , Fantasmas de Imagen
5.
BMC Med Imaging ; 21(1): 88, 2021 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-34022832

RESUMEN

BACKGROUND: MR fingerprinting (MRF) is a novel imaging method proposed for the diagnosis of Multiple Sclerosis (MS). This study aims to determine if MR Fingerprinting (MRF) relaxometry can differentiate frontal normal appearing white matter (F-NAWM) and splenium in patients diagnosed with MS as compared to controls and to characterize the relaxometry of demyelinating plaques relative to the time of diagnosis. METHODS: Three-dimensional (3D) MRF data were acquired on a 3.0T MRI system resulting in isotropic voxels (1 × 1 × 1 mm3) and a total acquisition time of 4 min 38 s. Data were collected on 18 subjects paired with 18 controls. Regions of interest were drawn over MRF-derived T1 relaxometry maps encompassing selected MS lesions, F-NAWM and splenium. T1 and T2 relaxometry features from those segmented areas were used to classify MS lesions from F-NAWM and splenium with T-distributed stochastic neighbor embedding algorithms. Partial least squares discriminant analysis was performed to discriminate NAWM and Splenium in MS compared with controls. RESULTS: Mean out-of-fold machine learning prediction accuracy for discriminant results between MS patients and controls for F-NAWM was 65 % (p = 0.21) and approached 90 % (p < 0.01) for the splenium. There was significant positive correlation between time since diagnosis and MS lesions mean T2 (p = 0.015), minimum T1 (p = 0.03) and negative correlation with splenium uniformity (p = 0.04). Perfect discrimination (AUC = 1) was achieved between selected features from MS lesions and F-NAWM. CONCLUSIONS: 3D-MRF has the ability to differentiate between MS and controls based on relaxometry properties from the F-NAWM and splenium. Whole brain coverage allows the assessment of quantitative properties within lesions that provide chronological assessment of the time from MS diagnosis.


Asunto(s)
Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Esclerosis Múltiple/diagnóstico por imagen , Área Bajo la Curva , Estudios de Casos y Controles , Cuerpo Calloso/diagnóstico por imagen , Femenino , Humanos , Análisis de los Mínimos Cuadrados , Aprendizaje Automático , Masculino , Persona de Mediana Edad , Proyectos Piloto , Sustancia Blanca/diagnóstico por imagen
8.
J Clin Neurophysiol ; 2023 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-37756021

RESUMEN

PURPOSE: Temporal encephaloceles are a cause of drug-resistant temporal lobe epilepsy; however, their relationship with epileptogenesis is unclear, and optimal surgical resection is uncertain. EEG source localization (ESL) may guide surgical decision-making. METHODS: We reviewed patients at Mayo Clinic Rochester with drug-resistant temporal lobe epilepsy and temporal encephaloceles, who underwent limited resection and had 1-year outcomes. EEG source localization was performed using standard density scalp EEG of ictal and interictal activity. Distance from dipole and standardized low-resolution brain electromagnetic tomography (sLORETA) solutions to the encephalocele were measured. Concordance of ESL with encephalocele and surgical resection was compared with 1-year surgical outcomes. RESULTS: Seventeen patients met criteria. The mean distances from ESL results to encephalocele center for dipole and sLORETA analyses were 23 mm (SD 9) and 22 mm (SD 11), respectively. Ten patients (55.6%) had Engel I outcomes at 1 year. Dipole-encephalocele distance and sLORETA-encephalocele distance were significantly longer in patients with Engel I outcome and patients whose encephalocele was contained by sLORETA had worse outcome as well; however, multiple logistic regression analysis found that only containment of encephalocele by the sLORETA current density was significant (P < 0.05), odds ratio 0.12 (95% confidence interval [0.021, 0.71]). CONCLUSIONS: EEG source localization of scalp EEG localizes near encephaloceles, however, typically not in the encephalocele itself; this may be due to scalp EEG sampling propagated activity or alternatively that the seizure onset zone extends beyond the herniated cortex. Surprisingly, we observed increased ESL to encephalocele distances in patients with excellent surgical outcomes. Larger cohort studies including intracranial EEG data are needed to further explore this finding.

9.
J Neurosurg Sci ; 66(1): 1-8, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30942050

RESUMEN

BACKGROUND: Identification of the central sulcus can require inspection of subtle differences or require certain pulse sequences. This study identifies the central sulcus by signal intensity on double inversion recovery (DIR) images in multiple anatomic locations and imaging planes. METHODS: Forty-nine patients (98 hemispheres) were retrospectively reviewed by three neuroradiologists and one radiology resident. The central sulcus was compared to the surrounding sulci for differences in signal intensity at axial hand knob, axial operculum, and lateral convexity sagittal images (294 locations) on DIR images. The use of the "disappearing central sulcus sign" where the window level is increased at constant width and black/white inversion were also assessed. RESULTS: In 49 patients (22 females, 27 males; median age 36 years), the central sulcus cortex signal intensity was lower than adjacent sulci with a frequency of 90/98 (91.8%) at the axial hand knob level, 68/98 (69.4%) at the axial operculum level, and 76/98 (77.5%) at the sagittal level. With black and white inversion, the frequencies were of 96/98 (98%), 92/98 (94%), and 87/98 (89%). The central sulcus was the first to disappear at all three levels with high degrees of inter-reader agreement (86-99%). Traditional anatomic landmarks were absent or conflicting in seven hemispheres (5 patients). The central sulcus was identified by DIR signal intensity in all seven hemispheres. CONCLUSIONS: The central sulcus can be identified by differences in signal intensity of the perirolandic cortex on DIR. Use of black/white inversion and the disappearing central sulcus sign may further facilitate identification.


Asunto(s)
Corteza Cerebral , Imagen por Resonancia Magnética , Adulto , Puntos Anatómicos de Referencia , Encéfalo , Corteza Cerebral/diagnóstico por imagen , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Estudios Retrospectivos
10.
J Clin Med ; 11(20)2022 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-36294304

RESUMEN

PURPOSE: To evaluate the performance of a new, highly flexible radiofrequency (RF) coil system for imaging patients undergoing MR simulation. METHODS: Volumetric phantom and in vivo images were acquired with a commercially available and prototype RF coil set. Phantom evaluation was performed using a silicone-filled humanoid phantom of the head and shoulders. In vivo assessment was performed in five healthy and six patient subjects. Phantom data included T1-weighted volumetric imaging, while in vivo acquisitions included both T1- and T2-weighted volumetric imaging. Signal to noise ratio (SNR) and uniformity metrics were calculated in the phantom data, while SNR values were calculated in vivo. Statistical significance was tested by means of a non-parametric analysis of variance test. RESULTS: At a threshold of p = 0.05, differences in measured SNR distributions within the entire phantom volume were statistically different in two of the three paired coil set comparisons. Differences in per slice average SNR between the two coil sets were all statistically significant, as well as differences in per slice image uniformity. For patients, SNRs within the entire imaging volume were statistically significantly different in four of the nine comparisons and seven of the nine comparisons performed on the per slice average SNR values. For healthy subjects, SNRs within the entire imaging volume were statistically significantly different in seven of the nine comparisons and eight of the nine comparisons when per slice average SNR was tested. CONCLUSIONS: Phantom and in vivo results demonstrate that image quality obtained from the novel flexible RF coil set was similar or improved over the conventional coil system. The results also demonstrate that image quality is impacted by the specific coil configurations used for imaging and should be matched appropriately to the anatomic site imaged to ensure optimal and reproducible image quality.

11.
Clin Imaging ; 64: 80-84, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32334271

RESUMEN

Accounting and finance are not typically a core educational offering in medical education. However, for physician leaders and leaders-in-grooming, it is prudent to be familiar with key financial indicators and ratios. The purpose of this review article is to provide fundamental information for emerging radiology physician leaders by describing important financial indicators and ratios, how they are defined and calculated, and, most importantly, how they can be interpreted and utilized for improving practice performance. SUMMARY SENTENCE: Understanding and implementing key financial ratios and indicators is important to maintain and improve financial performance in radiology practices.


Asunto(s)
Radiología/economía , Humanos
12.
Ann Clin Transl Neurol ; 6(9): 1807-1814, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31489797

RESUMEN

OBJECTIVE: To rigorously compare automated atlas-based and manual tracing hippocampal segmentation for accuracy, repeatability, and clinical acceptability given a relevant range of imaging abnormalities in clinical epilepsy. METHODS: Forty-nine patients with hippocampal asymmetry were identified from our institutional radiology database, including two patients with significant anatomic deformations. Manual hippocampal tracing was performed by experienced technologists on 3T MPRAGE images, measuring hippocampal volume up to the tectal plate, excluding the hippocampal tail. The same images were processed using NeuroQuant and FreeSurfer software. Ten subjects underwent repeated manual hippocampal tracings by two additional technologists blinded to previous results to evaluate consistency. Ten patients with two clinical MRI studies had volume measurements repeated using NeuroQuant and FreeSurfer. RESULTS: FreeSurfer raw volumes were significantly lower than NeuroQuant (P < 0.001, right and left), and hippocampal asymmetry estimates were lower for both automatic methods than manual tracing (P < 0.0001). Differences remained significant after scaling volumes to age, gender, and scanner matched normative percentiles. Volume reproducibility was fair (0.4-0.59) for manual tracing, and excellent (>0.75) for both automated methods. Asymmetry index reproducibility was excellent (>0.75) for manual tracing and FreeSurfer segmentation and fair (0.4-0.59) for NeuroQuant segmentation. Both automatic segmentation methods failed on the two cases with anatomic deformations. Segmentation errors were visually identified in 25 NeuroQuant and 27 FreeSurfer segmentations, and nine (18%) NeuroQuant and six (12%) FreeSurfer errors were judged clinically significant. INTERPRETATION: Automated hippocampal volumes are more reproducible than hand-traced hippocampal volumes. However, these methods fail in some cases, and significant segmentation errors can occur.


Asunto(s)
Hipocampo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Adolescente , Adulto , Anciano , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Reproducibilidad de los Resultados , Programas Informáticos , Adulto Joven
13.
J Nucl Med ; 60(10): 1340-1346, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31123099

RESUMEN

Since the introduction of simultaneous PET/MRI in 2011, there have been significant advancements. In this review, we highlight several technical advancements that have been made primarily in attenuation and motion correction and discuss the status of multiple clinical applications using PET/MRI. This review is based on the experience at the first PET/MRI conference cosponsored by the International Society for Magnetic Resonance in Medicine and the Society of Nuclear Medicine and Molecular Imaging.


Asunto(s)
Imagen Molecular , Tomografía de Emisión de Positrones , Enfermedades Cardiovasculares/diagnóstico por imagen , Chicago , Epilepsia/diagnóstico por imagen , Diseño de Equipo , Corazón/diagnóstico por imagen , Humanos , Aprendizaje Automático , Imagen por Resonancia Magnética/instrumentación , Oncología Médica/métodos , Imagen Molecular/instrumentación , Movimiento (Física) , Imagen Multimodal , Neoplasias/diagnóstico por imagen , Enfermedades Neurodegenerativas/diagnóstico por imagen , Medicina Nuclear/instrumentación , Tomografía de Emisión de Positrones/instrumentación , Nódulo Pulmonar Solitario/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Investigación Biomédica Traslacional , Flujo de Trabajo
14.
Epilepsy Res ; 140: 184-191, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29414526

RESUMEN

OBJECTIVE: Focal cortical dysplasia (FCD) is a common pathology in focal drug resistant epilepsy (DRE). Voxel based morphometric MRI analysis has been proposed as an adjunct to visual detection of FCD, which remains challenging given the subtle radiographic appearance of FCD. This study evaluates the diagnostic value of morphometric analysis program (MAP) in focal DRE with pathology-confirmed FCD. METHODS: Automated morphometric analysis program analysis generated z-score maps derived from T1 images, referenced to healthy adult or pediatric controls for each of 39 cases with pathology-confirmed FCD. MAP identified abnormal extension of gray matter into white matter (MAP-E) and blurring of the gray-white matter junction (MAP-J), independently of clinical data and other imaging modalities. MRI was visually reviewed by neuroradiologists as part of usual clinical care, and independently re-reviewed retrospectively by a neuroradiologist with >10-years' experience in epilepsy MRI. Sensitivity and specificity were calculated for MRI, MAP, scalp-EEG, PET and SISCOM compared to resection area (RA). RESULTS: In this cohort of 39 histologically proven FCD cases, the sensitivity and specificity of MAP-J [64% (95% CI 48%-77%) and 96% (95% CI 93%-0.98%)] and MAP-E [74% (95% CI 59%-86%) and 94% (95% CI 91%-97%)] were higher than qualitative MRI review, SISCOM, and FDG-PET. Initial MRI review detected FCD in 17, expert review identified 26. Among cases not detected by initial MRI review, MAP-J correctly identified FCD in 12 additional cases and MAP-E in 13 cases. Among cases not detected by expert MRI review, MAP-J correctly identified 6 and MAP-E 8 cases. Excellent surgical outcome was achieved in 76% of patients. SIGNIFICANCE: MAP showed favorable sensitivity compared to visual inspection and other non-invasive imaging modalities. MAP complements non-invasive imaging evaluation for detection of FCD in focal DRE patients.


Asunto(s)
Encéfalo/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética , Malformaciones del Desarrollo Cortical/diagnóstico por imagen , Adolescente , Adulto , Encéfalo/cirugía , Epilepsia Refractaria/diagnóstico por imagen , Epilepsia Refractaria/cirugía , Femenino , Sustancia Gris/diagnóstico por imagen , Sustancia Gris/cirugía , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Malformaciones del Desarrollo Cortical/cirugía , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/cirugía , Adulto Joven
15.
Phys Med Biol ; 63(8): 08NT02, 2018 04 13.
Artículo en Inglés | MEDLINE | ID: mdl-29537384

RESUMEN

The growth in the use of magnetic resonance imaging (MRI) data for radiation therapy (RT) treatment planning has been facilitated by scanner hardware and software advances that have enabled RT patients to be imaged in treatment position while providing morphologic and functional assessment of tumor volumes and surrounding normal tissues. Despite these advances, manufacturers have been slow to develop radiofrequency (RF) coils that closely follow the contour of a RT patient undergoing MR imaging. Instead, relatively large form surface coil arrays have been adapted from diagnostic imaging. These arrays can be challenging to place on, and in general do not conform to the patient's body habitus, resulting in sub optimal image quality. The purpose of this study is to report on the characterization of a new flexible and highly decoupled RF coil for use in MR imaging of RT patients. Coil performance was evaluated by performing signal-to-noise ratio (SNR) and noise correlation measurements using two coil (SNR) and four coil (noise correlation) element combinations as a function of coil overlap distance and comparing these values to those obtained using conventional coil elements. In vivo testing was performed in both normal volunteers and patients using a four and 16 element RF coil. Phantom experiments demonstrate the highly decoupled nature of the new coil elements when compared to conventional RF coils, while in vivo testing demonstrate that these coils can be integrated into extremely flexible and form fitting substrates that follow the exact contour of the patient. The new coil design addresses limitations imposed by traditional surface coil arrays and have the potential to significantly impact MR imaging for both diagnostic and RT applications.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Neoplasias/radioterapia , Fantasmas de Imagen , Ondas de Radio , Planificación de la Radioterapia Asistida por Computador/métodos , Relación Señal-Ruido , Anciano , Diseño de Equipo , Femenino , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Movimiento (Física) , Metástasis de la Neoplasia , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Programas Informáticos , Neoplasias de la Columna Vertebral/diagnóstico por imagen , Neoplasias de la Columna Vertebral/secundario
16.
Brain ; 129(Pt 6): 1385-98, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16613895

RESUMEN

Apraxia of speech (AOS) is a motor speech disorder characterized by slow speaking rate, abnormal prosody and distorted sound substitutions, additions, repetitions and prolongations, sometimes accompanied by groping, and trial and error articulatory movements. Although AOS is frequently subsumed under the heading of aphasia, and indeed most often co-occurs with aphasia, it can be the predominant or even the sole manifestation of a degenerative neurological disease. In this study we determine whether the clinical classifications of aphasia and AOS correlated with pathological diagnoses and specific biochemical and anatomical structural abnormalities. Seventeen cases with initial diagnoses of a degenerative aphasia or AOS were re-classified independently by two speech-language pathologists--blinded to pathological and biochemical findings--into one of five operationally defined categories of aphasia and AOS. Pathological diagnoses in the 17 cases were progressive supranuclear palsy in 6, corticobasal degeneration in 5, frontotemporal lobar degeneration with ubiquitin-only-immunoreactive changes in 5 and Pick's disease in 1. Magnetic resonance imaging analysis using voxel-based morphometry (VBM), and single photon emission tomography were completed, blinded to the clinical diagnoses, and clinicoimaging and clinicopathological associations were then sought. Interjudge clinical classification reliability was 87% (kappa = 0.8) for all evaluations. Eleven cases had evidence of AOS, of which all (100%) had a pathological diagnosis characterized by underlying tau biochemistry, while five of the other six cases without AOS did not have tau biochemistry (P = 0.001). A majority of the 17 cases had more than one yearly evaluation, demonstrating the evolution of the speech and language syndromes, as well as motor signs. VBM revealed the premotor and supplemental motor cortices to be the main cortical regions associated with AOS, while the anterior peri-sylvian region was associated with non-fluent aphasia. Refining the classification of the degenerative aphasias and AOS may be necessary to improve our understanding of the relationships among behavioural, pathological and imaging correlations.


Asunto(s)
Afasia/etiología , Apraxias/etiología , Enfermedades Neurodegenerativas/complicaciones , Anciano , Afasia/clasificación , Afasia/patología , Apraxias/clasificación , Apraxias/patología , Mapeo Encefálico/métodos , Femenino , Humanos , Pruebas del Lenguaje , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Corteza Motora/patología , Trastornos del Movimiento/etiología , Trastornos del Movimiento/patología , Enfermedades Neurodegenerativas/patología , Parálisis Supranuclear Progresiva/complicaciones , Parálisis Supranuclear Progresiva/patología , Tomografía Computarizada de Emisión de Fotón Único
17.
Parkinsonism Relat Disord ; 13(4): 230-9, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17196872

RESUMEN

The objective of this clinical-pathologic study was to identify biomarkers for a pallidopontonigral degeneration (PPND) kindred of frontotemporal dementia and parkinsonism linked to chromosome 17 (FTDP-17) harboring the N279K tau mutation. Five affected subjects, one at-risk who later became symptomatic, and one at-risk asymptomatic mutation carrier, had abnormal (18)fluorodeoxyglucose PET demonstrating asymmetric temporal lobe hypometabolism. All except the asymptomatic mutation carrier had abnormal brain MRI. Parkinsonism, myoclonus, anosmia, insomnia, speech, and autonomic dysfunction were identified. Autopsy of six affected subjects showed frontotemporal degeneration with extensive tauopathy. Further studies of FTDP-17 patients are needed to replicate these findings.


Asunto(s)
Asparagina/genética , Demencia/genética , Lisina/genética , Mutación , Trastornos Parkinsonianos/genética , Proteínas tau/genética , Adulto , Corteza Cerebral/diagnóstico por imagen , Corteza Cerebral/patología , Cromosomas Humanos Par 17 , Demencia/diagnóstico por imagen , Demencia/patología , Salud de la Familia , Femenino , Fluorodesoxiglucosa F18/farmacocinética , Humanos , Masculino , Persona de Mediana Edad , Pruebas Neuropsicológicas , Trastornos Parkinsonianos/diagnóstico por imagen , Trastornos Parkinsonianos/patología , Tomografía de Emisión de Positrones/métodos
18.
Magn Reson Imaging ; 25(3): 359-64, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17371725

RESUMEN

The ability to obtain high-quality images of small structures, such as the nerves of the inner ear, is important for the early diagnosis of numerous conditions. Balanced steady-state free precession (SSFP; e.g., true fast imaging with steady-state precession) is a fast acquisition method, but its use has been limited by the presence of off-resonance banding artifacts. To reduce these artifacts multiacquisition balanced SSFP with phase cycling is used, yielding multiple data sets in which the banding artifacts are spatially shifted with respect to each other (e.g., as in CISS). We present a new method, called nonlinear averaging (NLA), for combining these data sets to reduce banding artifacts. The NLA method arithmetically averages the three highest magnitude signals from four-phase-cycle SSFP data on a pixel-by-pixel basis. Simulations indicate that NLA offers improved signal-to-noise ratio (SNR) over the more standard maximum intensity projection (MIP) reconstruction. NLA is compared to MIP in simulations and volunteer tests. Simulations suggest that NLA provides substantially improved SNR compared to MIP. In a randomized blinded comparison of 10 volunteer studies, two radiologists found that NLA, compared to MIP, gave improved results. NLA also provided superior noise reduction and enhanced edge sharpness compared to MIP. We demonstrate that NLA, similar to MIP, improves SNR and image quality. It does so consistently in all situations to which it is applied.


Asunto(s)
Algoritmos , Artefactos , Oído Interno/anatomía & histología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Simulación por Computador , Humanos , Modelos Biológicos , Modelos Estadísticos , Dinámicas no Lineales , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
Nucl Med Commun ; 28(11): 834-41, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17901765

RESUMEN

OBJECTIVE: To determine the value of F-FDG PET/CT in the different manifestations of primary central nervous system lymphoma (PCNSL) in HIV-negative patients. METHODS: All PCNSL and HIV-negative patients referred for PET/CT in our institution from July 2001 to June 2006 were retrospectively studied. PET/CT examinations were reviewed by two experienced readers and evaluated for each possible anatomical site of nervous system involvement: cerebral, spinal/nerve and ocular. PET/CT results were characterized as true positive or negative and false positive or negative according to the status of the disease, which was determined after the evaluation of biopsies, laboratory, clinical and imaging examinations, and follow-up. RESULTS: Forty-two PET/CT examinations were carried out in 25 PCNSL patients. For intracerebral disease, PET/CT was true positive in 13 cases, true negative in 27 and false negative in two. For disease involving spinal cord and/or nerves, PET/CT was true positive in four cases, true negative in 37 and false negative in one. For ocular disease, PET was true positive in only one case and false negative in four. The sensitivity of PET/CT in detecting active disease in the brain was 87% (13/15), in the spine/nerves 80% (4/5), and in the eyes only 20% (1/5). CONCLUSION: PET/CT seems to be sensitive for the detection of viable intracerebral as well as for spinal and peripheral nerve disease, but not for the detection of ocular involvement.


Asunto(s)
Neoplasias del Sistema Nervioso Central/diagnóstico por imagen , Linfoma no Hodgkin/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Monoclonales/uso terapéutico , Anticuerpos Monoclonales de Origen Murino , Antimetabolitos Antineoplásicos/uso terapéutico , Antineoplásicos/uso terapéutico , Neoplasias del Sistema Nervioso Central/tratamiento farmacológico , Estudios de Cohortes , Femenino , Fluorodesoxiglucosa F18 , Seronegatividad para VIH , Humanos , Linfoma no Hodgkin/tratamiento farmacológico , Masculino , Metotrexato/uso terapéutico , Persona de Mediana Edad , Recurrencia Local de Neoplasia , Tomografía de Emisión de Positrones , Radiofármacos , Estudios Retrospectivos , Rituximab
20.
Otol Neurotol ; 28(2): 191-4, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17159492

RESUMEN

HYPOTHESIS: Improved resolution available with 64-slice multidetector computed tomography (MDCT) could potentially be used clinically to localize the cochlear implant (CI) electrode array within the basal turn. BACKGROUND: In CI surgery, the electrode array should be inserted into and remain within the scala tympani to avoid injury to Reissner's membrane and the scala media. Correlating the position of the electrode in the basal turn with surgical technique and implant design could be helpful in improving outcomes. METHODS: After a standard left mastoid exposure of the round window niche through the facial recess performed on a cadaver head, an electrode array from a Nucleus Softip Contour CI was fully inserted through a cochleostomy. The head was then scanned axially on a 64-slice MDCT with 0.4-mm slice thickness and reconstructed into the oblique axial, oblique coronal, and oblique sagittal planes of the cochlea. The temporal bone was then harvested and imaged on a microcomputed tomographic scanner using 20-microm slice thickness. Identical reconstructions were made and compared with the 64-slice images to confirm exact location of the electrode array. RESULTS: The 64-slice MDCT accurately localized the electrode array to the scala tympani. This was best demonstrated in the oblique sagittal plane, identifying the electrode array in the posterior inferior portion of the basal turn, posterior to the spiral lamina. CONCLUSION: This ex vivo validation study suggests that 64-slice MDCT has the potential to allow accurate localization of the CI electrode array within the basal turn of the cochlea.


Asunto(s)
Implantación Coclear , Microcomputadores , Tomografía Computarizada por Rayos X , Membrana Timpánica/anatomía & histología , Membrana Timpánica/diagnóstico por imagen , Cadáver , Electrodos Implantados , Humanos , Masculino , Hueso Temporal/citología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA