Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Optom Vis Sci ; 99(12): 875-884, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36594755

RESUMEN

SIGNIFICANCE: Peripheral prisms (p-prisms) improve blind-side detection of hazards in hemianopia by shifting the image of the hazard into the intact visual field. Collision judgments can be made accurately after detection by using a gaze shift to fixate the hazard in the prism-free portion of the lens, but this is slow relative to normal peripheral vision. A prior study found that prism adaptation for visual direction did not occur with general wear. We developed a perceptual-motor training regimen that resulted in accurate pointing at p-prism targets after six 1-hour sessions. PURPOSE: This study aimed to determine if improvements in pointing accuracy from perceptual-motor training generalized to collision judgments during simulated walking. METHODS: Participants with hemianopia (n = 13) made collision judgments in virtual reality for a person appearing 0.4 to 13.5° from the walking path. Judgments were measured under fixed gaze, requiring collision judgments via the p-prism image only, and free gaze, representing a more natural scenario. Measurements were made without and with p-prisms immediately after fitting, after a 2-week acclimation, after training, and 3 months later. Controls (n = 13) did one visit without p-prisms. RESULTS: Controls had 100% detection and symmetrically distributed collision judgments for the central 33 and 36% of hazards under fixed gaze and free gaze, respectively. In hemianopia, the seeing side was not different from controls. Blind-side detection was reduced without p-prisms to 40% fixed gaze and 82% free gaze and improved with p-prisms to 99% fixed gaze and 97% free gaze (P < .001). When first worn, fixed-gaze prism side collisions were 63 versus 37% on the seeing side and 41 versus 39% for free gaze (P < .001). There was a small improvement for fixed gaze after the 2-week acclimation (53%, P < .001), but no improvements from training or an additional 3 months of use. CONCLUSIONS: P-prisms improved detection, but collision judgments were inaccurate when seen only via the p-prisms and did not improve with perceptual-motor training. Patients should continue to be advised to turn their head and eyes to fixate the hazard after detection.


Asunto(s)
Hemianopsia , Juicio , Humanos , Anteojos , Visión Ocular , Campos Visuales
2.
Ophthalmic Physiol Opt ; 41(4): 842-852, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33774817

RESUMEN

PURPOSE: People with central vision loss (CVL) watch television, videos and movies, but often report difficulty and have reduced video comprehension. An approach to assist viewing videos is electronic magnification of the video itself, such as Bubble Magnification. METHODS: We created a Bubble Magnification technique that displayed a magnified segment around the centre of interest (COI) as determined by the gaze of participants with normal vision. The 15 participants with CVL viewed video clips shown with 2× and 3× Bubble Magnification, and unedited. We measured video comprehension and gaze coherence. RESULTS: Video comprehension was significantly worse with both 2× (p = 0.01) and 3× Bubble Magnification (p < 0.001) than the unedited video. There was no difference in gaze coherence across conditions (p ≥ 0.58). This was unexpected because we expected a benefit in both video comprehension and gaze coherence. This initial attempt to implement the Bubble Magnification method had flaws that probably reduced its effectiveness. CONCLUSIONS: In the future, we propose alternative implementations of Bubble Magnification, such as variable magnification and bubble size. This study is a first step in the development of an intelligent-magnification approach to providing a vision rehabilitation aid to assist people with CVL.


Asunto(s)
Comprensión , Baja Visión , Humanos , Películas Cinematográficas , Escotoma
3.
Health Qual Life Outcomes ; 18(1): 196, 2020 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-32571342

RESUMEN

PURPOSE: There have been few systematic reports of vision-related activity limitations of people with retinitis pigmentosa (RP). We report a merging of data from the National Eye Institute Visual Function Questionnaire (NEI-VFQ) obtained in five previous studies. We asked whether the Vision Function Scale (VFS; Pesudovs et al., 2010) which was developed for cataract patients would apply in this new population (condition). METHODS: Five hundred ninety-four individuals completed a total of 1753 questionnaires, with 209 participants providing responses over at least 4 years. Rasch analysis showed that the 15-item VFS was poorly targeted. A new instrument created by adding four driving-related items to the VFS had better targeting. As an indirect validation, VFS-plus person scores were compared to visual field area measured using a Goldmann perimeter, to the summed score for the combined 30-2 and 30/60-1 Humphrey Field Analyzer programs (HFA), to 30-Hz full-field cone electroretinogram (ERG) amplitude, and to ETDRS visual acuity. Changes in VFS-plus person scores with age and between four common heredity groups were also examined. RESULTS: The Rasch model of responses to the 19 VFS-plus items had person and item separation of 2.66 and 24.43 respectively. The VFS-plus person scores were related to each vision measure (p < 0.001). Over a five-year period, there was a reduction in person scores of 0.5 logits (p < 0.001). Person scores fell by an average of 0.34 logits per decade (p < 0.0001). Participants with an X-linked hereditary pattern had, on average, lower person scores (p < 0.001). CONCLUSIONS: The VFS-plus instrument quantified a highly-significant annual reduction in perceived vision-related ability over a five-year period. The outcome was consistent with clinical measures of vision, and detected lower perceived vision-related ability in participants with X-linked disease. It may be of use in future studies, but this needs to be tested in a representative population sample.


Asunto(s)
Actividades Cotidianas , Retinitis Pigmentosa/diagnóstico , Retinitis Pigmentosa/terapia , Encuestas y Cuestionarios/normas , Evaluación de Síntomas/normas , Baja Visión/terapia , Agudeza Visual/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , National Eye Institute (U.S.) , Reproducibilidad de los Resultados , Estados Unidos
4.
Optom Vis Sci ; 97(3): 207-217, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32168244

RESUMEN

SIGNIFICANCE: Electronic display devices used before bed may negatively affect sleep quality through the effects of short-wavelength (blue) light on melatonin production and the circadian cycle. We quantified the efficacy of night-mode functions and blue-light-reducing lenses in ameliorating this problem. PURPOSE: The purpose of this study was to compare the radiation produced by smartphones that reaches the eye when using night-mode functions or blue-light-reducing spectacle lenses. METHODS: Radiant flux of 64 smartphones was measured with an integrating sphere. The retinal illuminance was calculated from the radiant flux of the smartphones. For the night-mode functions, the spectra produced by the smartphones were measured. The transmittance of four blue-light-reducing spectacle lenses, which filter light with either antireflective coatings or tints, was measured using a spectrometer. To determine the impact of blue-light-reducing spectacles, the radiant flux of the smartphone was weighted by the transmission spectrum of these glasses. Visual and nonvisual (circadian) parameters were calculated to compute the melatonin suppression values (MSVs) through a logistic fitting of previously published data. The MSV was used as the figure of merit to evaluate the performance of blue-light spectacles and smartphone night-mode functions. RESULTS: Night-mode functions in smartphones reduced MSVs by up to 93%. The warmest mode produced the least suppression. Blue-light-reducing spectacles reduced melatonin suppression by 33%, the coated lenses being more efficient than tinted lenses. CONCLUSIONS: All smartphones in this study emit radiant power in the short-wavelength region of the visible spectrum. Such smartphones may impair the regulation of circadian cycles at nighttime. The activation of night-mode functions was more efficient than the commercially available blue-light-reducing spectacle lenses in reducing the amount of short-wavelength light (up to 2.25 times). These results can be extrapolated to most electronic devices because they share the same type of white radiant sources with smartphones.


Asunto(s)
Ritmo Circadiano/efectos de la radiación , Luz/efectos adversos , Protección Radiológica/métodos , Retina/efectos de la radiación , Teléfono Inteligente , Humanos , Melatonina/metabolismo , Refracción Ocular , Retina/metabolismo , Sueño/efectos de la radiación
5.
J Vis ; 20(7): 25, 2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33555170

RESUMEN

Although macular lesions often enlarge, we know little about what happens when the preferred retinal locus (PRL) is enveloped by the lesion. We present a prospective study of subjects with normal vision who were trained to develop a PRL using simulated scotomas with a gaze-contingent visual display. We hypothesized that, when subjects had developed a robust PRL and the scotoma size was increased, the PRL would move to remain outside the scotoma and in a direction that maintained the orientation (theta) of the PRL relative to the fovea. Nine subjects with normal vision were trained to develop a PRL and were then exposed to scotoma sizes that ranged from 4° to 24° in diameter. Subjects tracked a stimulus using saccades or smooth pursuits. Fixation stability was measured by calculating the bivariate contour ellipse area (BCEA). To measure the reassignment of the oculomotor reference (OMR) to the PRL, we analyzed the spread (BCEA) of saccade first landing points. All subjects developed a robust PRL that did not vary more than 0.8° on average between blocks of trials of a scotoma size, and they maintained the orientation of the PRL as the simulated scotoma size varied (±9° median standard deviation in theta, defined as orientation angle). Fixation stability and OMR to the PRL worsened (larger BCEA) with increasing scotoma size. This, and related studies, could guide development of a PRL training method to help people with central vision loss.


Asunto(s)
Orientación Espacial/fisiología , Retina/fisiopatología , Escotoma/fisiopatología , Campos Visuales/fisiología , Adulto , Movimientos Oculares/fisiología , Femenino , Fijación Ocular/fisiología , Humanos , Masculino , Estudios Prospectivos , Seguimiento Ocular Uniforme/fisiología , Adulto Joven
6.
Optom Vis Sci ; 95(9): 795-804, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30169355

RESUMEN

SIGNIFICANCE: The first report on the use of peripheral prisms (p-prisms) for patients with left neglect and homonymous visual field defects (HVFDs). PURPOSE: The purpose of this study was to investigate if patients with left hemispatial neglect and HVFDs benefit from p-prisms to expand the visual field and improve obstacle detection. METHODS: Patients (24 with HVFDs, 10 of whom had left neglect) viewed an animated, virtual, shopping mall corridor and reported if they would have collided with a human obstacle that appeared at various offsets up to 13.5° from their simulated walking path. There were 40 obstacle presentations on each side, with and without p-prisms. No training with p-prisms was provided, and gaze was fixed at the center of expansion. RESULTS: Detection on the side of the HVFD improved significantly with p-prisms in both groups, from 26 to 92% in the left-neglect group and 43 to 98% in the non-neglect group (both P < .001). There was a tendency for greater improvement in the neglect patients with p-prisms. For collision judgments, both groups exhibited a large increase in perceived collisions on the side of the HVFD with the prisms (P < .001), with no difference between the groups (P = .93). Increased perceived collisions represent a wider perceived safety margin on the side of the HVFD. CONCLUSIONS: Within the controlled conditions of this simulated, collision judgment task, patients with left neglect responded well to initial application of p-prisms exhibiting improved detection and wider safety margins on the side of the HVFD that did not differ from non-neglect patients. Further study of p-prisms for neglect patients in free-gaze conditions after extended wear and in real-world mobility tasks is clearly warranted.


Asunto(s)
Anteojos , Hemianopsia/fisiopatología , Trastornos de la Percepción/fisiopatología , Baja Visión/fisiopatología , Percepción Visual/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Juicio , Masculino , Persona de Mediana Edad , Pruebas del Campo Visual , Campos Visuales/fisiología , Adulto Joven
7.
Optom Vis Sci ; 95(5): 428-434, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29683986

RESUMEN

SIGNIFICANCE: Our survey found that participants with hemianopia report more difficulties watching video in various formats, including television (TV), on computers, and in a movie theater, compared with participants with normal vision (NV). These reported difficulties were not as marked as those reported by people with central vision loss. PURPOSE: The aim of this study was to survey the viewing experience (e.g., frequency, difficulty) of viewing video on TV, computers and portable visual display devices, and at the cinema of people with hemianopia and NV. This information may guide vision rehabilitation. METHODS: We administered a cross-sectional survey to investigate the viewing habits of people with hemianopia (n = 91) or NV (n = 192). The survey, consisting of 22 items, was administered either in person or in a telephone interview. Descriptive statistics are reported. RESULTS: There were five major differences between the hemianopia and NV groups. Many participants with hemianopia reported (1) at least "some" difficulty watching TV (39/82); (2) at least "some" difficulty watching video on a computer (16/62); (3) never attending the cinema (30/87); (4) at least some difficulty watching movies in the cinema (20/56), among those who did attend the cinema; and (5) never taking photographs (24/80). Some people with hemianopia reported methods that they used to help them watch video, including video playback and head turn. CONCLUSIONS: Although people with hemianopia report more difficulty with viewing video on TV and at the cinema, we are not aware of any rehabilitation methods specifically designed to assist people with hemianopia to watch video. The results of this survey may guide future vision rehabilitation.


Asunto(s)
Computadores , Hemianopsia/fisiopatología , Películas Cinematográficas , Fotograbar , Televisión , Baja Visión/fisiopatología , Campos Visuales/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Escotoma , Encuestas y Cuestionarios , Adulto Joven
8.
J Vis ; 17(14): 3, 2017 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-29196761

RESUMEN

Gaze-contingent displays have been widely used in vision research and virtual reality applications. Due to data transmission, image processing, and display preparation, the time delay between the eye tracker and the monitor update may lead to a misalignment between the eye position and the image manipulation during eye movements. We propose a method to reduce the misalignment using a Taylor series to predict the saccadic eye movement. The proposed method was evaluated using two large datasets including 219,335 human saccades (collected with an EyeLink 1000 system, 95% range from 1° to 32°) and 21,844 monkey saccades (collected with a scleral search coil, 95% range from 1° to 9°). When assuming a 10-ms time delay, the prediction of saccade movements using the proposed method could reduce the misalignment greater than the state-of-the-art methods. The average error was about 0.93° for human saccades and 0.26° for monkey saccades. Our results suggest that this proposed saccade prediction method will create more accurate gaze-contingent displays.


Asunto(s)
Movimientos Sacádicos/fisiología , Percepción Visual/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Animales , Movimientos Oculares , Femenino , Voluntarios Sanos , Humanos , Macaca mulatta , Masculino , Persona de Mediana Edad , Adulto Joven
9.
Behav Res Methods ; 46(2): 439-47, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23949955

RESUMEN

Gaze-contingent displays combine a display device with an eyetracking system to rapidly update an image on the basis of the measured eye position. All such systems have a delay, the system latency, between a change in gaze location and the related change in the display. The system latency is the result of the delays contributed by the eyetracker, the display computer, and the display, and it is affected by the properties of each component, which may include variability. We present a direct, simple, and low-cost method to measure the system latency. The technique uses a device to briefly blind the eyetracker system (e.g., for video-based eyetrackers, a device with infrared light-emitting diodes (LED)), creating an eyetracker event that triggers a change to the display monitor. The time between these two events, as captured by a relatively low-cost consumer camera with high-speed video capability (1,000 Hz), is an accurate measurement of the system latency. With multiple measurements, the distribution of system latencies can be characterized. The same approach can be used to synchronize the eye position time series and a video recording of the visual stimuli that would be displayed in a particular gaze-contingent experiment. We present system latency assessments for several popular types of displays and discuss what values are acceptable for different applications, as well as how system latencies might be improved.


Asunto(s)
Presentación de Datos , Movimientos Oculares/fisiología , Fijación Ocular/fisiología , Estudios de Tiempo y Movimiento , Interfaz Usuario-Computador , Computadores , Humanos , Modelos Biológicos , Fotograbar/instrumentación , Fotograbar/métodos , Tiempo de Reacción/fisiología , Escotoma/diagnóstico , Escotoma/fisiopatología , Grabación en Video
10.
Am J Ophthalmol ; 263: 168-178, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38461945

RESUMEN

PURPOSE: To evaluate ocular and retinal features of CRB1-associated early onset severe retinal dystrophy/Leber congenital amaurosis (EOSRD/LCA) for age-related changes. DESIGN: Retrospective cohort study. METHODS: Sixteen pediatric patients with biallelic CRB1 EOSRD/LCA who had been followed for up to 18 years were reviewed. Results of comprehensive ophthalmic examinations-including visual acuity, refractive error, dark-adapted visual threshold, Goldmann perimetry, and macular optical coherence tomography (OCT)-were analyzed for significant age-related changes using mixed-effects models. RESULTS: Visual acuity dark-adapted visual sensitivity, and area of seeing visual field (all subnormal from the earliest ages recorded) declined with increasing age. Hyperopia was stable through childhood and adolescence. In CRB1 EOSRD/LCA, OCT extrafoveal inner and outer laminar thicknesses exceeded those in controls but varied little with age, and foveal metrics (depth, breadth, thickness at rim) differed significantly from those in controls, but variations in foveal metrics were not associated with declines in acuity. CONCLUSIONS: From the youngest ages, retinal and visual function is significantly subnormal and becomes progressively compromized. A goal of future therapies should be intervention at young ages, when there is more function to be rescued.


Asunto(s)
Proteínas del Ojo , Amaurosis Congénita de Leber , Proteínas de la Membrana , Proteínas del Tejido Nervioso , Tomografía de Coherencia Óptica , Agudeza Visual , Campos Visuales , Humanos , Niño , Estudios Retrospectivos , Agudeza Visual/fisiología , Masculino , Adolescente , Femenino , Preescolar , Proteínas del Ojo/genética , Proteínas del Tejido Nervioso/genética , Proteínas de la Membrana/genética , Campos Visuales/fisiología , Amaurosis Congénita de Leber/genética , Amaurosis Congénita de Leber/fisiopatología , Pruebas del Campo Visual , Distrofias Retinianas/genética , Distrofias Retinianas/fisiopatología , Distrofias Retinianas/diagnóstico , Adaptación a la Oscuridad/fisiología , Lactante , Envejecimiento/fisiología , Estudios de Seguimiento , Retina/fisiopatología , Adulto Joven
11.
J Med Internet Res ; 15(5): e100, 2013 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-23689038

RESUMEN

BACKGROUND: Crowdsourcing has become a valuable method for collecting medical research data. This approach, recruiting through open calls on the Web, is particularly useful for assembling large normative datasets. However, it is not known how natural language datasets collected over the Web differ from those collected under controlled laboratory conditions. OBJECTIVE: To compare the natural language responses obtained from a crowdsourced sample of participants with responses collected in a conventional laboratory setting from participants recruited according to specific age and gender criteria. METHODS: We collected natural language descriptions of 200 half-minute movie clips, from Amazon Mechanical Turk workers (crowdsourced) and 60 participants recruited from the community (lab-sourced). Crowdsourced participants responded to as many clips as they wanted and typed their responses, whereas lab-sourced participants gave spoken responses to 40 clips, and their responses were transcribed. The content of the responses was evaluated using a take-one-out procedure, which compared responses to other responses to the same clip and to other clips, with a comparison of the average number of shared words. RESULTS: In contrast to the 13 months of recruiting that was required to collect normative data from 60 lab-sourced participants (with specific demographic characteristics), only 34 days were needed to collect normative data from 99 crowdsourced participants (contributing a median of 22 responses). The majority of crowdsourced workers were female, and the median age was 35 years, lower than the lab-sourced median of 62 years but similar to the median age of the US population. The responses contributed by the crowdsourced participants were longer on average, that is, 33 words compared to 28 words (P<.001), and they used a less varied vocabulary. However, there was strong similarity in the words used to describe a particular clip between the two datasets, as a cross-dataset count of shared words showed (P<.001). Within both datasets, responses contained substantial relevant content, with more words in common with responses to the same clip than to other clips (P<.001). There was evidence that responses from female and older crowdsourced participants had more shared words (P=.004 and .01 respectively), whereas younger participants had higher numbers of shared words in the lab-sourced population (P=.01). CONCLUSIONS: Crowdsourcing is an effective approach to quickly and economically collect a large reliable dataset of normative natural language responses.


Asunto(s)
Colaboración de las Masas , Recolección de Datos/métodos , Lenguajes de Programación , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estados Unidos , Adulto Joven
12.
J Vis ; 13(8)2013 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-23902753

RESUMEN

Gaze-contingent display paradigms play an important role in vision research. The time delay due to data transmission from eye tracker to monitor may lead to a misalignment between the gaze direction and image manipulation during eye movements, and therefore compromise the contingency. We present a method to reduce this misalignment by using a compressed exponential function to model the trajectories of saccadic eye movements. Our algorithm was evaluated using experimental data from 1,212 saccades ranging from 3° to 30°, which were collected with an EyeLink 1000 and a Dual-Purkinje Image (DPI) eye tracker. The model fits eye displacement with a high agreement (R² > 0.96). When assuming a 10-millisecond time delay, prediction of 2D saccade trajectories using our model could reduce the misalignment by 30% to 60% with the EyeLink tracker and 20% to 40% with the DPI tracker for saccades larger than 8°. Because a certain number of samples are required for model fitting, the prediction did not offer improvement for most small saccades and the early stages of large saccades. Evaluation was also performed for a simulated 100-Hz gaze-contingent display using the prerecorded saccade data. With prediction, the percentage of misalignment larger than 2° dropped from 45% to 20% for EyeLink and 42% to 26% for DPI data. These results suggest that the saccade-prediction algorithm may help create more accurate gaze-contingent displays.


Asunto(s)
Modelos Teóricos , Movimientos Sacádicos/fisiología , Percepción Visual/fisiología , Adulto , Algoritmos , Humanos
13.
Neuropsychology ; 37(7): 801-812, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36548079

RESUMEN

OBJECTIVE: The narrative description (ND) test objectively measures the ability to understand and describe visual scenes. As subtle differences in speech occur early in cognitive decline, we analyzed linguistic features for their utility in detecting cognitive impairment and predicting downstream decline. METHOD: Participants (n = 52) with normal cognition to mild dementia performed the ND test (watched twenty 30-s video clips and described the visual content). Cognitive function was followed for up to 5 years. We computed simple linguistic features such as content efficiency, speech rate, and part of speech and unique word counts. We examined (a) relationships between cognitive status and ND score and linguistic features; (b) ability to discriminate early cognitive impairment from normal cognition using ND score and linguistic features; and (c) whether ND score and linguistic features were associated with future cognitive functional decline. RESULTS: Many of the linguistic-feature metrics were related to cognitive status. Many of the linguistic features could distinguish between the cognitively normal group and the mild cognitive impairment (MCI) and Dementia groups. The area under the curve (AUC) for ND score alone was 0.74, with a nonsignificant increase to 0.78 when adding mean word length. Among participants with subjective cognitive decline (SCD) at the first visit, a smaller number of words plus more interjections or a lower ND score at baseline were predictive of future cognitive decline. CONCLUSIONS: While many linguistic features were associated with cognitive status, and some were able to detect early cognitive impairment or predictive of future cognitive decline, all the features we tested seem to have been captured by the ND score. Thus, adding linguistic measures to the ND test score did not add to its value in assessing current or predicting future cognitive status. (PsycInfo Database Record (c) 2023 APA, all rights reserved).


Asunto(s)
Enfermedad de Alzheimer , Disfunción Cognitiva , Demencia , Humanos , Enfermedad de Alzheimer/complicaciones , Enfermedad de Alzheimer/diagnóstico , Enfermedad de Alzheimer/psicología , Cognición , Disfunción Cognitiva/psicología , Demencia/complicaciones , Habla , Pruebas Neuropsicológicas
14.
Ophthalmic Genet ; 44(6): 585-590, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37038737

RESUMEN

BACKGROUND: Microcephaly and chorioretinopathy (MCCRP) is a rare autosomal recessive (AR) disorder characterized by microcephaly, developmental delay, chorioretinopathy, and visual impairment. We characterized the long-term phenotype of an additional patient with MCCRP associated with TUBCGP4 pathogenic variants and analysed previously reported cases in the literature. MATERIALS AND METHODS: Analysis of clinical and genetic data of a patient with TUBGCP4-related MCCRP followed for more than 19 years and literature search for previously reported patients with TUBCGP4 variants using PubMed, Scopus, and Google Scholar. RESULTS: Molecular diagnosis using exome sequencing demonstrated two TUBCGP4 variants in trans: c.1669C>T (p.Arg557*) and c.1746 G>T (p.Leu582=). Clinical characteristics included microcephaly, microphthalmia, punched-out chorioretinal lesions, vision impairment, nystagmus, Tetralogy of Fallot and neurodevelopmental delay. Another six previously reported cases of TUBCGP4-related MCCRP were identified. Their clinical and genetic characteristics are compared. CONCLUSIONS: TUBCGP4-related microcephaly and chorioretinopathy, is a rare autosomal recessive neuro-ophthalmic disorder. Clinical characteristics in our proband have remained stable for two decades. The pathophysiology of this syndrome is not yet fully understood.


Asunto(s)
Enfermedades de la Coroides , Microcefalia , Enfermedades de la Retina , Humanos , Microcefalia/genética , Microcefalia/patología , Enfermedades de la Retina/genética , Enfermedades de la Coroides/genética , Ojo , Familia , Fenotipo , Proteínas Asociadas a Microtúbulos/genética
15.
Transl Vis Sci Technol ; 12(12): 1, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-38038607

RESUMEN

Purpose: Examine the effect of force modulation via angular translation of a static magnetic field for customizable treatment of severe blepharoptosis. Methods: Prototype adjustable-force magnetic levator prostheses (aMLP) consisted of a spectacle-mounted magnet in rotatable housing and small eyelid-attached magnets embedded in a biocompatible polymer. Interpalpebral fissure (IPF) of 17 participants with severe blepharoptosis was continuously measured for one minute at five spectacle magnet angles, with order randomized and participant and data analyst masked. The hypothesis that angular position affected opening IPF (o-IPF), minimum blink IPF (m-IPF), and comfort ratings (1-10) was tested. Results: The aMLP improved o-IPF from 4.5 mm without the device to 6.2 mm on the lowest force setting (P < 0.001) and 7.1 mm on the highest setting (P < 0.001) and allowed for complete volitional blink regardless of setting (average m-IPF 0.4 mm and no change with aMLP; P = 0.76). Spontaneous blink without the device (2.0 mm) was affected on the highest force setting (m-IPF 3.9 mm; P < 0.001) but only marginally so on the lowest setting (3.0 mm; P = 0.06). Comfort (7.6/10) did not vary with the angle (P > 0.36). Profile analysis found substantial individual responses to angle (P < 0.001), confirming the value of customization. Conclusions: Angular translation provided adjustable force, which had a statistically and clinically meaningful impact on eye opening and the completeness of the spontaneous blink. This quantitative evidence supports continued use of the angular translation mechanism for force adjustment in the customizable magnetic correction of severe blepharoptosis. Translational Relevance: Evidence for the benefit of customizable magnetic force via angular translation in a larger sample of participants than reported previously.


Asunto(s)
Blefaroptosis , Humanos , Blefaroptosis/cirugía , Párpados , Prótesis e Implantes , Fenómenos Magnéticos
16.
Optom Vis Sci ; 89(9): E1364-73, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22863793

RESUMEN

PURPOSE: To determine whether image enhancement improves visual search performance and whether enhanced images were also preferred by subjects with vision impairment. METHODS: Subjects (n = 24) with vision impairment (vision: 20/52 to 20/240) completed visual search and preference tasks for 150 static images that were enhanced to increase object contours' visual saliency. Subjects were divided into two groups and were shown three enhancement levels. Original and medium enhancements were shown to both groups. High enhancement was shown to group 1, and low enhancement was shown to group 2. For search, subjects pointed to an object that matched a search target displayed at the top left of the screen. An "integrated search performance" measure (area under the curve of cumulative correct response rate over search time) quantified performance. For preference, subjects indicated the preferred side when viewing the same image with different enhancement levels on side-by-side high-definition televisions. RESULTS: Contour enhancement did not improve performance in the visual search task. Group 1 subjects significantly (p < 0.001) rejected the High enhancement, and showed no preference for medium enhancement over the original images. Group 2 subjects significantly preferred (p < 0.001) both the medium and the low enhancement levels over original. Contrast sensitivity was correlated with both preference and performance; subjects with worse contrast sensitivity performed worse in the search task (ρ = 0.77, p < 0.001) and preferred more enhancement (ρ = -0.47, p = 0.02). No correlation between visual search performance and enhancement preference was found. However, a small group of subjects (n = 6) in a narrow range of mid-contrast sensitivity performed better with the enhancement, and most (n = 5) also preferred the enhancement. CONCLUSIONS: Preferences for image enhancement can be dissociated from search performance in people with vision impairment. Further investigations are needed to study the relationships between preference and performance for a narrow range of mid-contrast sensitivity where a beneficial effect of enhancement may exist.


Asunto(s)
Sensibilidad de Contraste/fisiología , Percepción de Forma/fisiología , Análisis y Desempeño de Tareas , Baja Visión/fisiopatología , Campos Visuales/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad
17.
J Soc Inf Disp ; 20(11): 616-623, 2012 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-23483111

RESUMEN

Electronic magnification of an image results in a decrease in its perceived contrast. The decrease in perceived contrast could be due to a perceived blur or to limited sampling of the range of contrasts in the original image. We measured the effect on perceived contrast of magnification in two contexts: either a small video was enlarged to fill a larger area, or a portion of a larger video was enlarged to fill the same area as the original. Subjects attenuated the source video contrast to match the perceived contrast of the magnified videos, with the effect increasing with magnification and decreasing with viewing distance. These effects are consistent with expectations based on both the contrast statistics of natural images and the contrast sensitivity of the human visual system. We demonstrate that local regions within videos usually have lower physical contrast than the whole, and that this difference accounts for a minor part of the perceived differences. Instead, visibility of 'missing content' (blur) in a video is misinterpreted as a decrease in contrast. We detail how the effects of magnification on perceived contrast can be measured while avoiding confounding factors.

18.
Ophthalmic Physiol Opt ; 31(3): 258-74, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21410501

RESUMEN

PURPOSE: To survey the viewing experience (e.g. hours watched, difficulty) and viewing metrics (e.g. distance viewed, display size) for television (TV), computers and portable visual display devices for normally-sighted (NS) and visually impaired participants. This information may guide visual rehabilitation. METHODS: Survey was administered either in person or in a telephone interview on 223 participants of whom 104 had low vision (LV, worse than 6/18, age 22-90 years, 54 males), and 94 were NS (visual acuity 6/9 or better, age 20-86 years, 50 males). Depending on their situation, NS participants answered up to 38 questions and LV participants answered up to a further 10 questions. RESULTS: Many LV participants reported at least 'some' difficulty watching TV (71/103), reported at least 'often' having difficulty with computer displays (40/76) and extreme difficulty watching videos on handheld devices (11/16). The average daily TV viewing was slightly, but not significantly, higher for the LV participants (3.6 h) than the NS (3.0 h). Only 18% of LV participants used visual aids (all optical) to watch TV. Most LV participants obtained effective magnification from a reduced viewing distance for both TV and computer display. Younger LV participants also used a larger display when compared to older LV participants to obtain increased magnification. About half of the TV viewing time occurred in the absence of a companion for both the LV and the NS participants. The mean number of TVs at home reported by LV participants (2.2) was slightly but not significantly (p = 0.09) higher than NS participants (2.0). LV participants were equally likely to have a computer but were significantly (p = 0.004) less likely to access the internet (73/104) compared to NS participants (82/94). Most LV participants expressed an interest in image enhancing technology for TV viewing (67/104) and for computer use (50/74), if they used a computer. CONCLUSIONS: In this study, both NS and LV participants had comparable video viewing habits. Most LV participants in our sample reported difficulty watching TV, and indicated an interest in assistive technology, such as image enhancement. As our participants reported that at least half their video viewing hours are spent alone and that there is usually more than one TV per household, this suggests that there are opportunities to use image enhancement on the TVs of LV viewers without interfering with the viewing experience of NS viewers.


Asunto(s)
Computadores , Televisión , Trastornos de la Visión/fisiopatología , Actividades Cotidianas/psicología , Adulto , Anciano , Anciano de 80 o más Años , Recursos Audiovisuales , Medios de Comunicación , Femenino , Humanos , Entrevistas como Asunto , Masculino , Persona de Mediana Edad , Trastornos de la Visión/psicología , Trastornos de la Visión/rehabilitación , Adulto Joven
19.
IEEE Access ; 9: 52474-52484, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33981520

RESUMEN

The landing point of a saccade defines the new fixation region, the new region of interest. We asked whether it was possible to predict the saccade landing point early in this very fast eye movement. This work proposes a new algorithm based on LSTM networks and a fine-grained loss function for saccade landing point prediction in real-world scenarios. Predicting the landing point is a critical milestone toward reducing the problems caused by display-update latency in gaze-contingent systems that make real-time changes in the display based on eye tracking. Saccadic eye movements are some of the fastest human neuro-motor activities with angular velocities of up to 1,000°/s. We present a comprehensive analysis of the performance of our method using a database with almost 220,000 saccades from 75 participants captured during natural viewing of videos. We include a comparison with state-of-the-art saccade landing point prediction algorithms. The results obtained using our proposed method outperformed existing approaches with improvements of up to 50% error reduction. Finally, we analyzed some factors that affected prediction errors including duration, length, age, and user intrinsic characteristics.

20.
Transl Vis Sci Technol ; 10(8): 30, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-34323954

RESUMEN

Purpose: A larger display at the same viewing distance provides relative-size magnification for individuals with central vision loss (CVL). However, the resulting large visible area of the display is expected to result in more head rotation, which may cause discomfort. We created a zoom magnification technique that placed the center of interest (COI) in the center of the display to reduce the need for head rotation. Methods: In a 2 × 2 within-subject study design, 23 participants with CVL viewed video clips from 1.5 m (4.9 feet) shown with or without zoom magnification, and with a large (208 cm/82" diagonal, 69°) or a typical (84 cm/33", 31°) screen. Head position was tracked and a custom questionnaire was used to measure discomfort. Results: Video comprehension was better with the large screen (P < 0.001) and slightly worse with zoom magnification (P = 0.03). Oddly, head movements did not vary with screen size (P = 0.63), yet were greater with zoom magnification (P = 0.001). This finding was unexpected, because the COI remains in the center with zoom magnification, but moves widely with a large screen and no magnification. Conclusions: This initial attempt to implement the zoom magnification method had flaws that may have decreased its effectiveness. In the future, we propose alternative implementations for zoom magnification, such as variable magnification. Translational Relevance: We present the first explicit demonstration that relative-size magnification improves the video comprehension of people with CVL when viewing video.


Asunto(s)
Medios de Comunicación , Comprensión , Humanos , Escotoma
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA