Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Magn Reson Med ; 2024 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-38946234

RESUMEN

PURPOSE: Serine is a major source of one-carbon units needed for the synthesis of nucleotides and the production of intramitochondrial nicotinamide adenine dinucleotide phosphate (NADPH), and it plays an important role in cancer cell proliferation. The aim of this study was to develop a deuterium (2H) MRS imaging method for imaging tumor serine metabolism. METHODS: Sequential (2H) spectra and spectroscopic images were used to monitor the metabolism of [2,3,3-2H3]serine in patient-derived glioblastoma cells in vitro and in tumors obtained by their orthotopic implantation in mouse brain. RESULTS: [14,14-2H2] 5,10-methylene-tetrahydrofolate, [2H]glycine, [2H]formate, and labeled water were detected in cell suspensions and water labeling in spectroscopic images of tumors. Studies in cells and tumors with variable mitochondrial content and inhibitor studies in cells demonstrated that most of the labeled serine was metabolized in the mitochondria. Water labeling in the cell suspensions was correlated with formate labeling; therefore, water labeling observed in tumors could be used to provide a surrogate measure of flux in the pathway of one-carbon metabolism in vivo. CONCLUSION: The method has the potential to be used clinically to select patients for treatment with inhibitors of one-carbon metabolism and subsequently to detect their early responses to such treatment.

2.
Proc Natl Acad Sci U S A ; 118(12)2021 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-33727417

RESUMEN

2H magnetic resonance spectroscopic imaging has been shown recently to be a viable technique for metabolic imaging in the clinic. We show here that 2H MR spectroscopy and spectroscopic imaging measurements of [2,3-2H2]malate production from [2,3-2H2]fumarate can be used to detect tumor cell death in vivo via the production of labeled malate. Production of [2,3-2H2]malate, following injection of [2,3-2H2]fumarate (1 g/kg) into tumor-bearing mice, was measured in a murine lymphoma (EL4) treated with etoposide, and in human breast (MDA-MB-231) and colorectal (Colo205) xenografts treated with a TRAILR2 agonist, using surface-coil localized 2H MR spectroscopy at 7 T. Malate production was also imaged in EL4 tumors using a fast 2H chemical shift imaging sequence. The malate/fumarate ratio increased from 0.016 ± 0.02 to 0.16 ± 0.14 in EL4 tumors 48 h after drug treatment (P = 0.0024, n = 3), and from 0.019 ± 0.03 to 0.25 ± 0.23 in MDA-MB-231 tumors (P = 0.0001, n = 5) and from 0.016 ± 0.04 to 0.28 ± 0.26 in Colo205 tumors (P = 0.0002, n = 5) 24 h after drug treatment. These increases were correlated with increased levels of cell death measured in excised tumor sections obtained immediately after imaging. 2H MR measurements of [2,3-2H2]malate production from [2,3-2H2]fumarate provide a potentially less expensive and more sensitive method for detecting cell death in vivo than 13C MR measurements of hyperpolarized [1,4-13C2]fumarate metabolism, which have been used previously for this purpose.


Asunto(s)
Muerte Celular , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Imagen Molecular , Animales , Biomarcadores , Línea Celular Tumoral , Deuterio , Modelos Animales de Enfermedad , Fumaratos/metabolismo , Xenoinjertos , Humanos , Inmunohistoquímica , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Ratones , Imagen Molecular/métodos
3.
NMR Biomed ; 36(5): e4694, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-35032074

RESUMEN

BACKGROUND: The dual upregulation of TOP2A and EZH2 gene expression has been proposed as a biomarker for recurrence in prostate cancer patients to be treated with radical prostatectomy. A low tissue level of the metabolite citrate has additionally been connected to aggressive disease and recurrence in this patient group. However, for radiotherapy prostate cancer patients, few prognostic biomarkers have been suggested. The main aim of this study was to use an integrated tissue analysis to evaluate metabolites and expression of TOP2A and EZH2 as predictors for recurrence among radiotherapy patients. METHODS: From 90 prostate cancer patients (56 received neoadjuvant hormonal treatment), 172 transrectal ultrasound-guided (TRUS) biopsies were collected prior to radiotherapy. Metabolic profiles were acquired from fresh frozen TRUS biopsies using high resolution-magic angle spinning MRS. Histopathology and immunohistochemistry staining for TOP2A and EZH2 were performed on TRUS biopsies containing cancer cells (n = 65) from 46 patients, where 24 of these patients (n = 31 samples) received hormonal treatment. Eleven radical prostatectomy cohorts of a total of 2059 patients were used for validation in a meta-analysis. RESULTS: Among radiotherapy patients with up to 11 years of follow-up, a low level of citrate was found to predict recurrence, p = 0.001 (C-index = 0.74). Citrate had a higher predictive ability compared with individual clinical variables, highlighting its strength as a potential biomarker for recurrence. The dual upregulation of TOP2A and EZH2 was suggested as a biomarker for recurrence, particularly for patients not receiving neoadjuvant hormonal treatment, p = 0.001 (C-index = 0.84). While citrate was a statistically significant biomarker independent of hormonal treatment status, the current study indicated a potential of glutamine, glutamate and choline as biomarkers for recurrence among patients receiving neoadjuvant hormonal treatment, and glucose among patients not receiving neoadjuvant hormonal treatment. CONCLUSION: Using an integrated approach, our study shows the potential of citrate and the dual upregulation of TOP2A and EZH2 as biomarkers for recurrence among radiotherapy patients.


Asunto(s)
Neoplasias de la Próstata , Masculino , Humanos , Neoplasias de la Próstata/patología , Próstata/patología , Prostatectomía , Citratos , Proteína Potenciadora del Homólogo Zeste 2/genética , Proteína Potenciadora del Homólogo Zeste 2/metabolismo
4.
Magn Reson Med ; 87(2): 561-573, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34554604

RESUMEN

PURPOSE: Until now, 1 H MRSI of the prostate has been performed with suppression of the large water signal to avoid distortions of metabolite signals. However, this signal can be used for absolute quantification and spectral corrections. We investigated the feasibility of water-unsuppressed MRSI in patients with prostate cancer for water signal-mediated spectral quality improvement and determination of absolute tissue levels of choline. METHODS: Eight prostate cancer patients scheduled for radical prostatectomy underwent multi-parametric MRI at 3 T, including 3D water-unsuppressed semi-LASER MRSI. A postprocessing algorithm was developed to remove the water signal and its artifacts and use the extracted water signal as intravoxel reference for phase and frequency correction of metabolite signals and for absolute metabolite quantification. RESULTS: Water-unsuppressed MRSI with dedicated postprocessing produced water signal and artifact-free MR spectra throughout the prostate. In all patients, the absolute choline tissue concentration was significantly higher in tumorous than in benign tissue areas (mean ± SD: 7.2 ± 1.4 vs 3.8 ± 0.7 mM), facilitating tumor localization by choline mapping. Tumor tissue levels of choline correlated better with the commonly used (choline + spermine + creatine)/citrate ratio (r = 0.78 ± 0.1) than that of citrate (r = 0.21 ± 0.06). The highest maximum choline concentrations occurred in high-risk cancer foci. CONCLUSION: This report presents the first successful water-unsuppressed MRSI of the whole prostate. The water signal enabled amelioration of spectral quality and absolute metabolite quantification. In this way, choline tissue levels were identified as tumor biomarker. Choline mapping may serve as a tool in prostate cancer localization and risk scoring in multi-parametric MRI for diagnosis and biopsy procedures.


Asunto(s)
Colina , Neoplasias de la Próstata , Humanos , Espectroscopía de Resonancia Magnética , Masculino , Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Agua
5.
Magn Reson Med ; 88(5): 2014-2020, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35816502

RESUMEN

PURPOSE: There is an unmet clinical need for direct and sensitive methods to detect cell death in vivo, especially with regard to monitoring tumor treatment response. We have shown previously that tumor cell death can be detected in vivo from 2 H MRS and MRSI measurements of increased [2,3-2 H2 ]malate production following intravenous injection of [2,3-2 H2 ]fumarate. We show here that cell death can be detected with similar sensitivity following oral administration of the 2 H-labeled fumarate. METHODS: Mice with subcutaneously implanted EL4 tumors were fasted for 1 h before administration (200 µl) of [2,3-2 H2 ]fumarate (2 g/kg bodyweight) via oral gavage without anesthesia. The animals were then anesthetized, and after 30 min, tumor conversion of [2,3-2 H2 ]fumarate to [2,3-2 H2 ]malate was assessed from a series of 13 2 H spectra acquired over a period of 65 min. The 2 H spectra and 2 H spectroscopic images were acquired using a surface coil before and at 48 h after treatment with a chemotherapeutic drug (etoposide, 67 mg/kg). RESULTS: The malate/fumarate signal ratio increased from 0.022 ± 0.03 before drug treatment to 0.12 ± 0.04 following treatment (p = 0.023, n = 4). Labeled malate was undetectable in spectroscopic images acquired before treatment and increased in the tumor area following treatment. The increase in the malate/fumarate signal ratio was similar to that observed previously following intravenous administration of labeled fumarate. CONCLUSION: Orally administered [2,3-2 H2 ]fumarate can be used to detect tumor cell death noninvasively following treatment with a sensitivity that is similar to that obtained with intravenous administration.


Asunto(s)
Fumaratos , Neoplasias , Animales , Muerte Celular , Deuterio , Fumaratos/química , Malatos/química , Malatos/metabolismo , Malatos/uso terapéutico , Ratones , Neoplasias/diagnóstico por imagen , Neoplasias/tratamiento farmacológico , Neoplasias/metabolismo
6.
Magn Reson Med ; 87(5): 2130-2144, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34866238

RESUMEN

PURPOSE: The performance of pulse sequences in vivo can be limited by fast relaxation rates, magnetic field inhomogeneity, and nonuniform spin excitation. We describe here a method for pulse sequence optimization that uses a stochastic numerical solver that in principle is capable of finding a global optimum. The method provides a simple framework for incorporating any constraint and implementing arbitrarily complex cost functions. Efficient methods for simulating spin dynamics and incorporating frequency selectivity are also described. METHODS: Optimized pulse sequences for polarization transfer between protons and X-nuclei and excitation pulses that eliminate J-coupling modulation were evaluated experimentally using a surface coil on phantoms, and also the detection of hyperpolarized [2-13 C]lactate in vivo in the case of J-coupling modulation-free excitation. RESULTS: The optimized polarization transfer pulses improved the SNR by ~50% with a more than twofold reduction in the B1 field, and J-coupling modulation-free excitation was achieved with a more than threefold reduction in pulse length. CONCLUSION: This process could be used to optimize any pulse when there is a need to improve the uniformity and frequency selectivity of excitation as well as to design new pulses to steer the spin system to any desired achievable state.


Asunto(s)
Algoritmos , Protones , Ácido Láctico , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen
7.
Magn Reson Med ; 85(6): 3027-3035, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33421253

RESUMEN

PURPOSE: To compare carbon-13 (13 C) MRSI of hyperpolarized [1-13 C]pyruvate metabolism in a murine tumor model with mass spectrometric (MS) imaging of the corresponding tumor sections in order to cross validate these metabolic imaging techniques and to investigate the effects of pyruvate delivery and tumor lactate concentration on lactate labeling. METHODS: [1-13 C]lactate images were obtained from tumor-bearing mice, following injection of hyperpolarized [1-13 C]pyruvate, using a single-shot 3D 13 C spectroscopic imaging sequence in vivo and using desorption electrospray ionization MS imaging of the corresponding rapidly frozen tumor sections ex vivo. The images were coregistered, and levels of association were determined by means of Spearman rank correlation and Cohen kappa coefficients as well as linear mixed models. The correlation between [1-13 C]pyruvate and [1-13 C]lactate in the MRS images and between [12 C] and [1-13 C]lactate in the MS images were determined by means of Pearson correlation coefficients. RESULTS: [1-13 C]lactate images generated by MS imaging were significantly correlated with the corresponding MRS images. The correlation coefficient between [1-13 C]lactate and [1-13 C]pyruvate in the MRS images was higher than between [1-13 C]lactate and [12 C]lactate in the MS images. CONCLUSION: The inhomogeneous distribution of labeled lactate observed in the MRS images was confirmed by MS imaging of the corresponding tumor sections. The images acquired using both techniques show that the rate of 13 C label exchange between the injected pyruvate and endogenous tumor lactate pool is more correlated with the rate of pyruvate delivery to the tumor cells and is less affected by the endogenous lactate concentration.


Asunto(s)
Linfoma , Ácido Pirúvico , Animales , Isótopos de Carbono , Ácido Láctico , Linfoma/diagnóstico por imagen , Imagen por Resonancia Magnética , Espectrometría de Masas , Ratones
8.
NMR Biomed ; 34(2): e4443, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33200468

RESUMEN

Modern MRI systems usually load the predesigned RFs and the accompanying gradients during clinical scans, with minimal adaption to the specific requirements of each scan. Here, we describe a neural network-based method for real-time design of excitation RF pulses and the accompanying gradients' waveforms to achieve spatially two-dimensional selectivity. Nine thousand sets of radio frequency (RF) and gradient waveforms with two-dimensional spatial selectivity were generated as the training dataset using the Shinnar-Le Roux (SLR) method. Neural networks were created and trained with five strategies (TS-1 to TS-5). The neural network-designed RF and gradients were compared with their SLR-designed counterparts and underwent Bloch simulation and phantom imaging to investigate their performances in spin manipulations. We demonstrate a convolutional neural network (TS-5) with multi-task learning to yield both the RF pulses and the accompanying two channels of gradient waveforms that comply with the SLR design, and these design results also provide excitation spatial profiles comparable with SLR pulses in both simulation (normalized root mean square error [NRMSE] of 0.0075 ± 0.0038 over the 400 sets of testing data between TS-5 and SLR) and phantom imaging. The output RF and gradient waveforms between the neural network and SLR methods were also compared, and the joint NRMSE, with both RF and the two channels of gradient waveforms considered, was 0.0098 ± 0.0024 between TS-5 and SLR. The RF and gradients were generated on a commercially available workstation, which took ~130 ms for TS-5. In conclusion, we present a convolutional neural network with multi-task learning, trained with SLR transformation pairs, that is capable of simultaneously generating RF and two channels of gradient waveforms, given the desired spatially two-dimensional excitation profiles.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Redes Neurales de la Computación , Ondas de Radio , Conjuntos de Datos como Asunto , Diseño de Equipo , Fantasmas de Imagen
10.
MAGMA ; 34(1): 49-56, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32910316

RESUMEN

OBJECTIVES: To enhance detection of the products of hyperpolarized [2-13C]dihydroxyacetone metabolism for assessment of three metabolic pathways in the liver in vivo. Hyperpolarized [2-13C]DHAc emerged as a promising substrate to follow gluconeogenesis, glycolysis and the glycerol pathways. However, the use of [2-13C]DHAc in vivo has not taken off because (i) the chemical shift range of [2-13C]DHAc and its metabolic products span over 144 ppm, and (ii) 1H decoupling is required to increase spectral resolution and sensitivity. While these issues are trivial for high-field vertical-bore NMR spectrometers, horizontal-bore small-animal MR scanners are seldom equipped for such experiments. METHODS: Real-time hepatic metabolism of three fed mice was probed by 1H-decoupled 13C-MR following injection of hyperpolarized [2-13C]DHAc. The spectra of [2-13C]DHAc and its metabolic products were acquired in a 7 T small-animal MR scanner using three purpose-designed spectral-spatial radiofrequency pulses that excited a spatial bandwidth of 8 mm with varying spectral bandwidths and central frequencies (chemical shifts). RESULTS: The metabolic products detected in vivo include glycerol 3-phosphate, glycerol, phosphoenolpyruvate, lactate, alanine, glyceraldehyde 3-phosphate and glucose 6-phosphate. The metabolite-to-substrate ratios were comparable to those reported previously in perfused liver. DISCUSSION: Three metabolic pathways can be probed simultaneously in the mouse liver in vivo, in real time,  using hyperpolarized DHAc.


Asunto(s)
Dihidroxiacetona/química , Animales , Isótopos de Carbono , Gluconeogénesis , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Ratones , Protones
11.
Radiology ; 294(2): 289-296, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31821119

RESUMEN

Background Tumor cells frequently show high rates of aerobic glycolysis, which provides the glycolytic intermediates needed for the increased biosynthetic demands of rapid cell growth and proliferation. Existing clinical methods (fluorodeoxyglucose PET and carbon 13 MRI and spectroscopy) do not allow quantitative images of glycolytic flux. Purpose To evaluate the use of deuterium (hydrogen 2 [2H]) MR spectroscopic imaging for quantitative mapping of tumor glycolytic flux and to assess response to chemotherapy. Materials and Methods A fast three-dimensional 2H MR spectroscopic imaging pulse sequence, with a time resolution of 10 minutes, was used to image glycolytic flux in a murine tumor model after bolus injection of D-[6,6'-2H2]glucose before and 48 hours after treatment with a chemotherapeutic agent. Tumor lactate labeling, expressed as the lactate-to-water and lactate-to-glucose signal ratios, was also assessed in localized 2H MR spectra. Statistical significance was tested with a one-sided paired t test. Results 2H MR spectroscopic imaging showed heterogeneity in glycolytic flux across the tumor and an early decrease in flux following treatment with a chemotherapeutic drug. Spectroscopy measurements on five animals showed a decrease in the lactate-to-water signal ratio, from 0.33 ± 0.10 to 0.089 ± 0.039 (P = .005), and in the lactate-to-glucose ratio, from 0.27 ± 0.12 to 0.12 ± 0.06 (P = .04), following drug treatment. Conclusion Rapidly acquired deuterium (hydrogen 2) MR spectroscopic images can provide quantitative and spatially resolved measurements of glycolytic flux in tumors that can be used to assess treatment response. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Ouwerkerk in this issue.


Asunto(s)
Glucólisis , Imagenología Tridimensional/métodos , Linfoma/diagnóstico por imagen , Espectroscopía de Resonancia Magnética/métodos , Animales , Antineoplásicos/uso terapéutico , Línea Celular Tumoral , Deuterio , Modelos Animales de Enfermedad , Linfoma/tratamiento farmacológico , Ratones , Tiempo
12.
Magn Reson Med ; 84(4): 1895-1908, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32173908

RESUMEN

PURPOSE: Imaging tumor metabolism in vivo using hyperpolarized [1-13 C]pyruvate is a promising technique for detecting disease, monitoring disease progression, and assessing treatment response. However, the transient nature of the hyperpolarization and its depletion following excitation limits the available time for imaging. We describe here a single-shot multi spin echo sequence, which improves on previously reported sequences, with a shorter readout time, isotropic point spread function (PSF), and better signal-to-noise ratio. METHODS: The sequence uses numerically optimized spectrally selective excitation pulses set to the resonant frequencies of pyruvate and lactate and a hyperbolic secant adiabatic refocusing pulse, all applied in the absence of slice selection gradients. The excitation pulses were designed to be resistant to the effects of B0 and B1 field inhomogeneity. The gradient readout uses a 3D cone trajectory composed of 13 cones, all fully refocused and distributed among 7 spin echoes. The maximal gradient amplitude and slew rate were set to 4 G/cm and 20 G/cm/ms, respectively, to demonstrate the feasibility of clinical translation. RESULTS: The pulse sequence gave an isotropic PSF of 2.8 mm. The excitation profiles of the optimized pulses closely matched simulations and a 46.10 ± 0.04% gain in image SNR was observed compared to a conventional Shinnar-Le Roux excitation pulse. The sequence was demonstrated with dynamic imaging of hyperpolarized [1-13 C]pyruvate and [1-13 C]lactate in vivo. CONCLUSION: The pulse sequence was capable of dynamic imaging of hyperpolarized 13 C labeled metabolites in vivo with relatively high spatial and temporal resolution and immunity to system imperfections.


Asunto(s)
Algoritmos , Aumento de la Imagen , Imagen por Resonancia Magnética , Fantasmas de Imagen , Ácido Pirúvico , Relación Señal-Ruido
13.
Magn Reson Med ; 84(4): 1844-1856, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32153046

RESUMEN

PURPOSE: Hyperpolarized 15 N-labeled molecules have been proposed as imaging agents for investigating tissue perfusion and pH. However, the sensitivity of direct 15 N detection is limited by the isotope's low gyromagnetic ratio. Sensitivity can be increased by transferring 15 N hyperpolarization to spin-coupled protons provided that there is not significant polarization loss during transfer. However, complete polarization transfer would limit the temporal window for imaging to the order of the proton T1 (2-3 s). To exploit the long T1 offered by storing polarization in 15 N and the higher sensitivity of 1 H detection, we have developed a pulse sequence for partial polarization transfer. METHODS: A polarization transfer pulse sequence was modified to allow partial polarization transfer, as is required for dynamic measurements, and that can be implemented with inhomogeneous B1 fields, as is often the case in vivo. The sequence was demonstrated with dynamic spectroscopy and imaging measurements with [15 N2 ]urea. RESULTS: When compared to direct 15 N detection, the sequence increased the signal-to-noise ratio (SNR) by a factor of 1.72 ± 0.25, where both experiments depleted ~20% of the hyperpolarization (>10-fold when 100% of the hyperpolarization is used). Simulations with measured cross relaxation rates showed that this sequence gave up to a 50-fold increase in urea proton polarization when compared to spontaneous polarization transfer via cross relaxation. CONCLUSION: The sequence gave an SNR increase that was close to the theoretical limit and can give a significant SNR benefit when compared to direct 13 C detection of hyperpolarized [13 C]urea.


Asunto(s)
Protones , Urea , Espectroscopía de Resonancia Magnética , Relación Señal-Ruido
14.
Nat Chem Biol ; 14(11): 1032-1042, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30297875

RESUMEN

α-Ketoglutarate (αKG) is a key node in many important metabolic pathways. The αKG analog N-oxalylglycine (NOG) and its cell-permeable prodrug dimethyloxalylglycine (DMOG) are extensively used to inhibit αKG-dependent dioxygenases. However, whether NOG interference with other αKG-dependent processes contributes to its mode of action remains poorly understood. Here we show that, in aqueous solutions, DMOG is rapidly hydrolyzed, yielding methyloxalylglycine (MOG). MOG elicits cytotoxicity in a manner that depends on its transport by monocarboxylate transporter 2 (MCT2) and is associated with decreased glutamine-derived tricarboxylic acid-cycle flux, suppressed mitochondrial respiration and decreased ATP production. MCT2-facilitated entry of MOG into cells leads to sufficiently high concentrations of NOG to inhibit multiple enzymes in glutamine metabolism, including glutamate dehydrogenase. These findings reveal that MCT2 dictates the mode of action of NOG by determining its intracellular concentration and have important implications for the use of (D)MOG in studying αKG-dependent signaling and metabolism.


Asunto(s)
Aminoácidos Dicarboxílicos/química , Ácidos Cetoglutáricos/química , Transportadores de Ácidos Monocarboxílicos/metabolismo , Adenosina Trifosfato/química , Animales , Fenómenos Bioquímicos , Bovinos , Línea Celular Tumoral , Ciclo del Ácido Cítrico , Perfilación de la Expresión Génica , Glutamina/metabolismo , Humanos , Hidrólisis , Concentración 50 Inhibidora , Células MCF-7 , Metabolómica , Ratones , Mitocondrias/metabolismo , Oxígeno/química , Puromicina/química , Transducción de Señal , Ácidos Tricarboxílicos/química
15.
NMR Biomed ; 32(1): e4035, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30457686

RESUMEN

PURPOSE: A relatively high signal for choline-containing compounds (total choline, tCho) is commonly found in 1 H MR spectra of malignant tumors, but it is unclear if this also occurs in tumors in the liver. We evaluated the potential of the tCho signal in single voxel 1 H MR spectra of the human liver to assess metastases of colorectal cancers. EXPERIMENT: MR spectra of an 8 cm3 PRESS-localized voxel were obtained at 3 T from the livers of 12 healthy volunteers and from metastatic lesions in 20 patients in two different sessions. To correct for motion artifacts, sequentially recorded spectra were individually phased and frequency aligned before averaging. Spectra were analyzed using LCModel and tissue levels estimated by water referencing. Repeatability was assessed with Bland-Altman analyses. To estimate tumor necrosis, diffusion-weighted imaging of the liver was performed. High resolution magic angle spinning (HRMAS) spectra of tumor and normal liver samples were obtained at 11.7 T. RESULTS: With increasing tumor volumes, tCho levels decreased, indicating a partial volume effect. Mean tCho content in tumors larger than the PRESS voxel (>8 cm3 ) was significantly lower (p < 0.01) than for normal liver: 1.6 (range 0.0-3.4) versus 6.9 (range 4.9-11.1) mmol/kg wet weight, while it was comparable for tumors smaller than 8 cm3 : 7.0 (range 3.8-9.3) mmol/kg. The higher 90th percentile apparent diffusion coefficient value in the larger lesions indicates more necrosis. Measurement repeatability was average in normal livers and poor in tumors. HRMAS did not show substantial differences in choline-containing compounds between normal liver and metastasis. CONCLUSION: An increased tCho content was not observed in 1 H MR spectra of liver metastasis of colorectal cancer, compared with normal liver. This may be due to the background of a high tCho signal in spectra of normal liver or to an intrinsic lower tCho content in these tumors, but is most likely the result of necrosis in metastatic tumor tissue.


Asunto(s)
Colina/metabolismo , Neoplasias Colorrectales/patología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Hígado/metabolismo , Espectroscopía de Protones por Resonancia Magnética , Adulto , Anciano , Imagen de Difusión por Resonancia Magnética , Humanos , Metaboloma , Persona de Mediana Edad , Control de Calidad , Reproducibilidad de los Resultados
16.
J Biol Chem ; 292(5): 1737-1748, 2017 02 03.
Artículo en Inglés | MEDLINE | ID: mdl-27994059

RESUMEN

Rapid cancer cell proliferation promotes the production of reducing equivalents, which counteract the effects of relatively high levels of reactive oxygen species. Reactive oxygen species levels increase in response to chemotherapy and cell death, whereas an increase in antioxidant capacity can confer resistance to chemotherapy and is associated with an aggressive tumor phenotype. The pentose phosphate pathway is a major site of NADPH production in the cell, which is used to maintain the main intracellular antioxidant, glutathione, in its reduced state. Previous studies have shown that the rate of hyperpolarized [1-13C]dehydroascorbic acid (DHA) reduction, which can be measured in vivo using non-invasive 13C magnetic resonance spectroscopic imaging, is increased in tumors and that this is correlated with the levels of reduced glutathione. We show here that the rate of hyperpolarized [1-13C]DHA reduction is increased in tumors that have been oxidatively prestressed by depleting the glutathione pool by buthionine sulfoximine treatment. This increase was associated with a corresponding increase in pentose phosphate pathway flux, assessed using 13C-labeled glucose, and an increase in glutaredoxin activity, which catalyzes the glutathione-dependent reduction of DHA. These results show that the rate of DHA reduction depends not only on the level of reduced glutathione, but also on the rate of NADPH production, contradicting the conclusions of some previous studies. Hyperpolarized [1-13C]DHA can be used, therefore, to assess the capacity of tumor cells to resist oxidative stress in vivo However, DHA administration resulted in transient respiratory arrest and cardiac depression, which may prevent translation to the clinic.


Asunto(s)
Ácido Deshidroascórbico/metabolismo , NADP/metabolismo , Neoplasias/metabolismo , Estrés Oxidativo , Animales , Isótopos de Carbono , Línea Celular Tumoral , Humanos , Marcaje Isotópico , Espectroscopía de Resonancia Magnética , Ratones
17.
J Am Chem Soc ; 140(43): 14455-14463, 2018 10 31.
Artículo en Inglés | MEDLINE | ID: mdl-30346733

RESUMEN

Whether for 13C magnetic resonance studies in chemistry, biochemistry, or biomedicine, hyperpolarization methods based on dynamic nuclear polarization (DNP) have become ubiquitous. DNP requires a source of unpaired electrons, which are commonly added to the sample to be hyperpolarized in the form of stable free radicals. Once polarized, the presence of these radicals is unwanted. These radicals can be replaced by nonpersistent radicals created by the photoirradiation of pyruvic acid (PA), which are annihilated upon dissolution or thermalization in the solid state. However, since PA is readily metabolized by most cells, its presence may be undesirable for some metabolic studies. In addition, some 13C substrates are photosensitive and therefore may degrade during the photogeneration of a PA radical, which requires ultraviolet (UV) light. We show here that the photoirradiation of phenylglyoxylic acid (PhGA) using visible light produces a nonpersistent radical that, in principle, can be used to hyperpolarize any molecule. We compare radical yields in samples containing PA and PhGA upon photoirradiation with broadband and narrowband UV-visible light sources. To demonstrate the suitability of PhGA as a radical precursor for DNP, we polarized the gluconeogenic probe 13C-dihydroxyacetone, which is UV-sensitive, using a commercial 3.35 T DNP polarizer and then injected this into a mouse and followed its metabolism in vivo.

18.
Magn Reson Med ; 79(2): 741-747, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-28474393

RESUMEN

PURPOSE: Dynamic magnetic resonance spectroscopic imaging of hyperpolarized 13 C-labeled cell substrates has enabled the investigation of tissue metabolism in vivo. Currently observation of these hyperpolarized substrates is limited mainly to 13 C detection. We describe here an imaging pulse sequence that enables proton observation by using polarization transfer from the hyperpolarized 13 C nucleus to spin-coupled protons. METHODS: The pulse sequence transfers 13 C hyperpolarization to 1 H using a modified reverse insensitive nuclei enhanced by polarization transfer (INEPT) sequence that acquires a fully refocused echo. The resulting hyperpolarized 1 H signal is acquired using a 2D echo-planar trajectory. The efficiency of polarization transfer was investigated using simulations with and without T1 and T2 relaxation of both the 1 H and 13 C nuclei. RESULTS: Simulations showed that 1 H detection of the hyperpolarized 13 C nucleus in lactate should increase significantly the signal-to-noise ratio when compared with direct 13 C detection at 3T. However the advantage of 1 H detection is expected to disappear at higher fields. Dynamic 1 H images of hyperpolarized [1-13 C]lactate, with a spatial resolution of 1.25 × 1.25 mm2 , were acquired from a phantom injected with hyperpolarized [1-13 C]lactate and from tumors in vivo following injection of hyperpolarized [1-13 C]pyruvate. CONCLUSIONS: The sequence allows 1 H imaging of hyperpolarized 13 C-labeled substrates in vivo. Magn Reson Med 79:741-747, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Asunto(s)
Isótopos de Carbono/metabolismo , Procesamiento de Imagen Asistido por Computador/métodos , Ácido Láctico/metabolismo , Imagen por Resonancia Magnética/métodos , Animales , Encéfalo/metabolismo , Isótopos de Carbono/química , Ácido Láctico/química , Ratones , Fantasmas de Imagen , Ácido Pirúvico/química , Ácido Pirúvico/metabolismo , Ratas
19.
Magn Reson Med ; 79(5): 2500-2510, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-28994492

RESUMEN

PURPOSE: To investigate and compare human judgment and machine learning tools for quality assessment of clinical MR spectra of brain tumors. METHODS: A very large set of 2574 single voxel spectra with short and long echo time from the eTUMOUR and INTERPRET databases were used for this analysis. Original human quality ratings from these studies as well as new human guidelines were used to train different machine learning algorithms for automatic quality control (AQC) based on various feature extraction methods and classification tools. The performance was compared with variance in human judgment. RESULTS: AQC built using the RUSBoost classifier that combats imbalanced training data performed best. When furnished with a large range of spectral and derived features where the most crucial ones had been selected by the TreeBagger algorithm it showed better specificity (98%) in judging spectra from an independent test-set than previously published methods. Optimal performance was reached with a virtual three-class ranking system. CONCLUSION: Our results suggest that feature space should be relatively large for the case of MR tumor spectra and that three-class labels may be beneficial for AQC. The best AQC algorithm showed a performance in rejecting spectra that was comparable to that of a panel of human expert spectroscopists. Magn Reson Med 79:2500-2510, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Aprendizaje Automático , Imagen por Resonancia Magnética/métodos , Algoritmos , Encéfalo/diagnóstico por imagen , Humanos , Control de Calidad
20.
NMR Biomed ; 31(11): e4004, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30198124

RESUMEN

Hyperpolarized MRI with 13 C-labeled metabolites has enabled metabolic imaging of tumors in vivo. The heterogeneous nature of tumors and the limited lifetime of the hyperpolarization require high resolution, both temporally and spatially. We describe two sequences that make more efficient use of the 13 C polarization than previously described single-shot 3D sequences. With these sequences, the target metabolite resonances were excited using spectral-spatial pulses and the data acquired using spiral readouts from a series of echoes created using a fast-spin-echo sequence employing adiabatic 180° pulses. The third dimension was encoded with blipped gradients applied in an interleaved order to the echo train. Adiabatic inversion pulses applied in the absence of slice selection gradients allowed acquisition of signal from odd echoes, formed by unpaired adiabatic pulses, as well as from even echoes. The sequences were tested on tumor-bearing mice following intravenous injection of hyperpolarized [1-13 C]pyruvate. [1-13 C] pyruvate and [1-13 C] lactate images were acquired in vivo with a 4 × 4 × 2 cm3 field of view and a 32 × 32 × 16 matrix, leading to a nominal resolution of 1.25 × 1.25 × 1.25 mm3 and an effective resolution of 1.25 × 1.25 × 4.5 mm3 when the z-direction point spread function was taken into account. The acquisition of signal from more echoes also allowed for an improvement in the signal-to-noise ratio for resonances with longer T2 relaxation times. The pulse sequences described here produced hyperpolarized 13 C images with improved resolution and signal-to-noise ratio when compared with similar sequences described previously.


Asunto(s)
Algoritmos , Espectroscopía de Resonancia Magnética con Carbono-13 , Imagenología Tridimensional , Animales , Ácido Láctico/metabolismo , Ratones , Fantasmas de Imagen , Ácido Pirúvico/metabolismo , Procesamiento de Señales Asistido por Computador , Marcadores de Spin
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA