Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Org Chem ; 89(5): 3150-3160, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38335273

RESUMEN

A practical synthesis of valuable N-acyl anthranilic acids has been achieved via a silver-catalyzed imino-ketene generation from readily available anthranils and carboxylic acids. A wide range of carboxylic acids including sterically demanding aliphatic carboxylic acids, aromatic carboxylic acids, acrylic acids, and amino acids are compatible in this reaction. Moreover, this method can be used to modify drug molecules and natural products, such as ibuprofen, probenecid, and acetylglycine.

2.
Phys Rev Lett ; 128(7): 075001, 2022 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-35244411

RESUMEN

A new method for measuring the time-dependent drive flux at the hohlraum center is proposed as a better alternative to conventional wall-based techniques. The drive flux here is obtained by simultaneous measurement of the reemitted flux and shock velocity from a three-layered "cakelike" sample. With these two independent observables, the influence induced by the uncertainty of the material parameters of the sample can be effectively decreased. The influence from the closure of the laser entrance hole, which was the main challenge in conventional wall-based techniques, was avoided through localized reemitted flux measurement, facilitating drive flux measurement throughout the entire time history. These studies pave a new way for probing the time-dependent drive flux, for both cylindrical hohlraums and novel hohlraums with six laser entrance holes.

3.
Phys Rev Lett ; 109(14): 145004, 2012 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-23083253

RESUMEN

The proposal of simultaneously determining the hohlraum peak radiation temperature T(R) and M-band fraction f(M) by shock velocity measurement technique [Y. S. Li et al. Phys. Plasmas 18, 022701 (2011)] is demonstrated for the first time in recent experiments conducted on SGIII-prototype laser facility. In the experiments, T(R) and f(M) are determined by using the observed shock velocities in Al and Ti. For the Au hohlraum used in the experiments, T(R) is about 160 eV and f(M) is around 4.3% under a 1 ns laser pulse of 2 kJ. The results from this method are complementary to those from the broadband x-ray spectrometer, and the technique can be further used to determine T(R) and f(M) inside an ignition hohlraum.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA