Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Nature ; 601(7891): 53-57, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34987217

RESUMEN

The standard model of particle physics is both incredibly successful and glaringly incomplete. Among the questions left open is the striking imbalance of matter and antimatter in the observable universe1, which inspires experiments to compare the fundamental properties of matter/antimatter conjugates with high precision2-5. Our experiments deal with direct investigations of the fundamental properties of protons and antiprotons, performing spectroscopy in advanced cryogenic Penning trap systems6. For instance, we previously compared the proton/antiproton magnetic moments with 1.5 parts per billion fractional precision7,8, which improved upon previous best measurements9 by a factor of greater than 3,000. Here we report on a new comparison of the proton/antiproton charge-to-mass ratios with a fractional uncertainty of 16 parts per trillion. Our result is based on the combination of four independent long-term studies, recorded in a total time span of 1.5 years. We use different measurement methods and experimental set-ups incorporating different systematic effects. The final result, [Formula: see text], is consistent with the fundamental charge-parity-time reversal invariance, and improves the precision of our previous best measurement6 by a factor of 4.3. The measurement tests the standard model at an energy scale of 1.96 × 10-27 gigaelectronvolts (confidence level 0.68), and improves ten coefficients of the standard model extension10. Our cyclotron clock study also constrains hypothetical interactions mediating violations of the clock weak equivalence principle (WEPcc) for antimatter to less than 1.8 × 10-7, and enables the first differential test of the WEPcc using antiprotons11. From this interpretation we constrain the differential WEPcc-violating coefficient to less than 0.030.

2.
Phys Rev Lett ; 133(5): 053201, 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39159098

RESUMEN

We demonstrate efficient subthermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures T_{+}=E_{+}/k_{B} below 200 mK in preparation times shorter than 500 s. This corresponds to the fastest resistive single-particle cyclotron cooling to subthermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we demonstrate the detection of antiproton spin transitions with an error rate <0.000 023, more than 3 orders of magnitude better than in previous best experiments. This method has enormous impact on multi-Penning-trap experiments that measure magnetic moments with single nuclear spins for tests of matter and antimatter symmetry, high-precision mass spectrometry, and measurements of electron g factors bound to highly charged ions that test quantum electrodynamics and establish standards for magnetometry.

3.
Artículo en Inglés | MEDLINE | ID: mdl-37288385

RESUMEN

Abstract: The BASE collaboration at the antiproton decelerator/ELENA facility of CERN compares the fundamental properties of protons and antiprotons with ultra-high precision. Using advanced Penning trap systems, we have measured the proton and antiproton magnetic moments with fractional uncertainties of 300 parts in a trillion (p.p.t.) and 1.5 parts in a billion (p.p.b.), respectively. The combined measurements improve the resolution of the previous best test in that sector by more than a factor of 3000. Very recently, we have compared the antiproton/proton charge-to-mass ratios with a fractional precision of 16 p.p.t., which improved the previous best measurement by a factor of 4.3. These results allowed us also to perform a differential matter/antimatter clock comparison test to limits better than 3%. Our measurements enable us to set limits on 22 coefficients of CPT- and Lorentz-violating standard model extensions (SME) and to search for potentially asymmetric interactions between antimatter and dark matter. In this article, we review some of the recent achievements and outline recent progress towards a planned improved measurement of the antiproton magnetic moment with an at least tenfold improved fractional accuracy.

4.
Rev Sci Instrum ; 93(9): 093303, 2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36182508

RESUMEN

We describe a newly developed polytetrafluoroethylene/copper capacitor driven by a cryogenic piezoelectric slip-stick stage and demonstrate with the chosen layout cryogenic capacitance tuning of ≈60 pF at ≈10 pF background capacitance. Connected to a highly sensitive superconducting toroidal LC circuit, we demonstrate tuning of the resonant frequency between 345 and 685 kHz, at quality factors Q > 100 000. Connected to a cryogenic ultra low noise amplifier, a frequency tuning range between 520 and 710 kHz is reached, while quality factors Q > 86 000 are achieved. This new device can be used as a versatile image current detector in high-precision Penning-trap experiments or as an LC-circuit-based haloscope detector to search for the conversion of axion-like dark matter to radio-frequency photons. This new development increases the sensitive detection bandwidth of our axion haloscope by a factor of ≈1000.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA