Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 103(6): 1023-1034, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38639143

RESUMEN

BACKGROUND: The clinical efficacy and safety of alcohol septal ablation (ASA) for obstructive hypertrophic cardiomyopathy (HCM) have been well-established; however, less is known about outcomes in patients undergoing preemptive ASA before transcatheter mitral valve replacement (TMVR). AIMS: The goal of this study is to characterize the procedural characteristics and examine the clinical outcomes of ASA in both HCM and pre-TMVR. METHODS: This retrospective study compared procedural characteristics and outcomes in patient who underwent ASA for HCM and TMVR. RESULTS: In total, 137 patients were included, 86 in the HCM group and 51 in the TMVR group. The intraventricular septal thickness (mean 1.8 vs. 1.2 cm; p < 0.0001) and the pre-ASA LVOT gradient (73.6 vs. 33.8 mmHg; p ≤ 0.001) were higher in the HCM group vs the TMVR group. The mean volume of ethanol injected was higher (mean 2.4 vs. 1.7 cc; p < 0.0001). The average neo-left ventricular outflow tract area increased significantly after ASA in the patients undergoing TMVR (99.2 ± 83.37 mm2 vs. 196.5 ± 114.55 mm2; p = <0.0001). The HCM group had a greater reduction in the LVOT gradient after ASA vs the TMVR group (49.3 vs. 18 mmHg; p = 0.0040). The primary composite endpoint was higher in the TMVR group versus the HCM group (50.9% vs. 25.6%; p = 0.0404) and had a higher incidence of new permanent pacemaker (PPM) (25.5% vs. 18.6%; p = 0.3402). The TMVR group had a higher rate of all-cause mortality (9.8% vs. 1.2%; p = 0.0268). CONCLUSIONS: Preemptive ASA before TMVR was performed in patients with higher degree of clinical comorbidities, and correspondingly is associated with worse short-term clinical outcomes in comparison to ASA for HCM patients. ASA before TMVR enabled percutaneous mitral interventions in a small but significant minority of patients that would have otherwise been excluded. The degree of LVOT and neoLVOT area increase is significant and predictable.


Asunto(s)
Técnicas de Ablación , Cateterismo Cardíaco , Cardiomiopatía Hipertrófica , Etanol , Implantación de Prótesis de Válvulas Cardíacas , Válvula Mitral , Humanos , Estudios Retrospectivos , Masculino , Etanol/administración & dosificación , Etanol/efectos adversos , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Cardiomiopatía Hipertrófica/mortalidad , Cardiomiopatía Hipertrófica/terapia , Cardiomiopatía Hipertrófica/cirugía , Cardiomiopatía Hipertrófica/fisiopatología , Femenino , Resultado del Tratamiento , Técnicas de Ablación/efectos adversos , Técnicas de Ablación/mortalidad , Anciano , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Cateterismo Cardíaco/instrumentación , Persona de Mediana Edad , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Factores de Tiempo , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Recuperación de la Función , Anciano de 80 o más Años , Tabiques Cardíacos/diagnóstico por imagen , Tabiques Cardíacos/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad
2.
Catheter Cardiovasc Interv ; 98(6): 1193-1203, 2021 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-34106514

RESUMEN

BACKGROUND: Due to elevated surgical risk, transcatheter mitral valve replacement (TMVR) is used as an alternative for treating failed bioprosthetic valves, annuloplasty repairs and mitral annular calcification (MAC). We report the procedural and longitudinal outcomes for each subtype: Mitral valve-in-valve (MVIV), mitral valve-in-ring (MViR), and valve-in-MAC (ViMAC). METHODS: Consecutive patients undergoing TMVR from October 2013 to December 2019 were assessed. Patients at high risk for left ventricular outflow tract obstruction had either alcohol septal ablation or intentional laceration of the anterior leaflet (LAMPOON). RESULTS: Eight-eight patients underwent TMVR; 38 MViV, 31 MViR, and 19 ViMAC procedures were performed. The median Society of Thoracic Surgery 30-day predicted risk of mortality was 8.2% (IQR 5.2, 19.9) for all. Sapien 3 (78%) and transseptal access (98%) were utilized in most cases. All-cause in-hospital mortality, technical, and procedural success were 8%, 83%, and 66% respectively. Median follow up was 1.4 years (IQR 0.5-2.9 years) and overall survival was 40% at 4 years. Differential survival rates were observed with MViV doing the best, followed by MViR and ViMAC having a <20% survival at 4 years. After adjusting for co-variates, MViV procedure was the strongest predictor of survival (HR 0.24 [95% CI 0.079-0.7]). CONCLUSION: TMVR is performed in at high-risk patients with attenuated long-term survival. MViV has the best success and survival rate, but long-term survival in MViR and ViMAC is guarded.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
3.
J Cardiothorac Vasc Anesth ; 35(9): 2607-2612, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33441271

RESUMEN

OBJECTIVES: Transcaval transcatheter aortic valve replacement (TC-TAVR) is an alternative approach to transcatheter aortic valve replacement involving deployment of the bioprosthetic valve via a conduit created from the inferior vena cava to the descending aorta in patients for whom the traditional transfemoral approach is not feasible. By analyzing the largest known cohort of TC-TAVR patients, the authors wished to compare hospital length of stay and post-procedure outcomes between patients who underwent the procedure under deep sedation (DS) and patients who underwent general anesthesia with an endotracheal tube. DESIGN: Retrospective, single-center study. SETTING: Henry Ford Hospital in Detroit, MI. PARTICIPANTS: Patients undergoing TC-TAVR from 2015 to 2018. MEASUREMENTS AND MAIN RESULTS: Seventy-nine patients were included in the analysis, which consisted of 38 under general anesthesia with an endotracheal tube and 41 under DS. The sample was divided into a general anesthesia (GA) group and DS group. There were no significant differences in implant success rate or post-procedure outcomes, including in-hospital mortality (p = 0.999) and major vascular complication rate (p = 0.481), between the two groups. Patients in the GA group stayed a median of 24 hours longer in the intensive care unit (ICU) (p < 0.001) and one day longer in the hospital (p = 0.046) after the procedure compared to patients in the DS group. The median procedure time was significantly lower (135 minutes) in the DS group compared to the GA group (167 minutes, p < 0.001). CONCLUSIONS: Patients undergoing TC-TAVR under DS had similar postoperative outcomes and shorter post-procedure hospital and ICU lengths of stay compared to general anesthesia. In the authors' experience, DS is the preferred anesthetic technique for TC-TAVR.


Asunto(s)
Anestesia General , Estenosis de la Válvula Aórtica , Sedación Profunda , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Intubación Intratraqueal , Tiempo de Internación , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 96(2): 481-487, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31957915

RESUMEN

OBJECTIVES: To examine the safety of utilizing transapical access during structural interventions. BACKGROUND: Complex interventions of the mitral or aortic region sometimes require coaxial forces to orient and deliver devices. Apical access can provide coaxial countertraction for either transseptal or retrograde aortic access. This manuscript describes the single center experience of small bore transapical access. METHODS: Retrospective review of cases from 2013 to 2018 at Henry Ford Hospital was performed. Patient demographics and procedure characteristics were abstracted to describe the safety of transapical access using small bore sheaths. RESULTS: A total 21 cases were performed at Henry Ford, most of them for transcatheter mitral valve replacement (81%). The mean sheath size used was 4.7 ± 0.9 Fr and protamine was used at the end of 57% of cases. All patients received nitinol-based plugs, 80.1% were from the Amplatz Duct Occluder II type. Four major complications related apical puncture occurred, two pericardial effusions, two hemothorax. Over a median follow time of 430 days (IQR 50-652) a total of five deaths occurred, two related to the procedure and three late deaths with a median time of 362 days (range 205-628 days). No deaths were associated with transapical access. Echocardiographic follow up did not detect any late structural complications from occluder devices. CONCLUSIONS: Transapical access and closure with nitinol-based devices is feasible and facilitates complex interventions where coaxial forces are need for device delivery and alignment. The most common complication is bleeding and this should be kept in perspective when treating high-risk patients.


Asunto(s)
Cateterismo Cardíaco , Cardiopatías/terapia , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Catéteres Cardíacos , Bases de Datos Factuales , Diseño de Equipo , Femenino , Cardiopatías/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Dispositivo Oclusor Septal , Resultado del Tratamiento
5.
Catheter Cardiovasc Interv ; 96(3): 659-663, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32251546

RESUMEN

The coronavirus disease-2019 (COVID-19) pandemic has strained health care resources around the world, causing many institutions to curtail or stop elective procedures. This has resulted in an inability to care for patients with valvular and structural heart disease in a timely fashion, potentially placing these patients at increased risk for adverse cardiovascular complications, including CHF and death. The effective triage of these patients has become challenging in the current environment, as clinicians have had to weigh the risk of bringing susceptible patients into the hospital environment during the COVID-19 pandemic against the risk of delaying a needed procedure. In this document, the authors suggest guidelines for how to triage patients in need of structural heart disease interventions and provide a framework for how to decide when it may be appropriate to proceed with intervention despite the ongoing pandemic. In particular, the authors address the triage of patients in need of transcatheter aortic valve replacement and percutaneous mitral valve repair. The authors also address procedural issues and considerations for the function of structural heart disease teams during the COVID-19 pandemic.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/estadística & datos numéricos , Infecciones por Coronavirus/epidemiología , Cardiopatías/cirugía , Pandemias/estadística & datos numéricos , Neumonía Viral/epidemiología , Guías de Práctica Clínica como Asunto , Triaje/normas , COVID-19 , Procedimientos Quirúrgicos Cardíacos/métodos , Cardiología/métodos , Cardiología/normas , Infecciones por Coronavirus/prevención & control , Infección Hospitalaria/prevención & control , Femenino , Cardiopatías/diagnóstico por imagen , Humanos , Masculino , Salud Laboral/estadística & datos numéricos , Pandemias/prevención & control , Seguridad del Paciente , Neumonía Viral/prevención & control , Sociedades Médicas , Triaje/estadística & datos numéricos , Estados Unidos
6.
J Cardiothorac Vasc Anesth ; 33(12): 3303-3308, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30850225

RESUMEN

OBJECTIVE: To compare outcomes among patients with and without preprocedural radial arterial catheters who underwent transfemoral transcatheter aortic valve replacement (TF-TAVR) under deep intravenous (IV) sedation and to assess predictive variables for preprocedural placement. DESIGN: Single-center, retrospective, cohort analysis. SETTING: Department of Anesthesiology, Pain Management and Perioperative Medicine, Henry Ford Hospital, which is a tertiary care, university-affiliated hospital. PARTICIPANTS: The study comprised 157 patients. The primary focus was the 106 patients who underwent TF-TAVR when routine placement of preprocedure radial arterial catheters was abandoned. They were analyzed for hospital length of stay, 30-day mortality, and predictive factors of preprocedure placement. The remaining patients served as historical controls when routine radial artery catheter placement was practiced. INTERVENTIONS: Patient, procedure, and provider factors were analyzed. The transitional period consisted of 169 consecutive days from April 13 to September 28, 2017. A reference group of historical patients served as a control. MEASUREMENTS AND MAIN RESULTS: Seventy-five of 106 patients did not have a preprocedural radial arterial catheter. The primary outcome measures of length of stay and 30-day mortality within the transitional group were not different. Secondary outcome measures included identification of predictive variables for preprocedure placement and outcome comparisons between the transitional and historical groups. Anesthesia provider (p = 0.015) and ejection fraction (p = 0.039) were significant factors. There were no differences in outcome measures. CONCLUSION: There was no difference in primary outcomes in patients with or without radial arterial catheters for TF-TAVR. The findings of this study suggest anesthesia provider and ejection fraction were significant factors for preprocedural placement.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Presión Sanguínea/fisiología , Cateterismo Periférico/métodos , Sedación Consciente/métodos , Monitoreo Fisiológico/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Ecocardiografía Transesofágica , Femenino , Arteria Femoral , Estudios de Seguimiento , Humanos , Tiempo de Internación/tendencias , Masculino , Arteria Radial , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
7.
Catheter Cardiovasc Interv ; 92(2): 401-407, 2018 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-29388306

RESUMEN

BACKGROUND: Preliminary data comparing 3-dimensional computed tomography (3D-CT) to transesophageal echocardiography (TEE) for left atrial appendage occlusion (LAAO) indicates that 3D-CT provides more accurate measurements and improves case planning. Therefore, we conducted a pilot study comparing 3D-CT to TEE in occluder selection accuracy and procedural efficiency. METHODS: From May 2016 to February 2017, 24 patients were prospectively randomized to undergo LAAO using either TEE or 3D-CT. The primary endpoint was device accuracy while the secondary endpoints included # devices per case, # guide catheters used per case, # fluoroscopy angles used, procedure time, fluoroscopy time, radiation dose, and major adverse events (stroke, MI, device embolization, perforation, death). RESULTS: Procedure success was 100% and 92% for the 3D-CT and 2D-TEE cohorts respectively. Accuracy for 1st device selection 92% and 27% (P = .01) for 3D-CT and 2D-TEE respectively but with intra-procedural upsizing in the 2D-TEE cohort, the 2D-TEE cohort accuracy increased to 64% while the 3D-CT groups 92% was accurate (P = .33). Case planning using 3D-CT was significantly more efficient with respect to device utilization (CT 1.33 ± 0.7 vs. 2D-TEE 2.5 ± 1.2 P = .01), guide catheters (CT 1 vs. 2D-TEE 1.7 ± 0.8 P = .01) and procedure time (3D-CT 55 ± 17 min vs. 2D-TEE 73 ± 24 min P < .05). One major adverse event, a stroke occurred in the 2D-TEE group. CONCLUSION: In this single-center pilot study, CT guided LAAO case planning was associated with improved device selection accuracy and procedural efficiency. This study data supports the notion that comprehensive 3D assessment significantly simplifies LAAO, minimizing the time and number of steps needed.


Asunto(s)
Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Cateterismo Cardíaco/métodos , Ecocardiografía Transesofágica , Imagenología Tridimensional , Radiografía Intervencional/métodos , Tomografía Computarizada por Rayos X , Ultrasonografía Intervencional/métodos , Anciano , Anciano de 80 o más Años , Apéndice Atrial/fisiopatología , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Ecocardiografía Transesofágica/efectos adversos , Femenino , Humanos , Imagenología Tridimensional/efectos adversos , Masculino , Michigan , Proyectos Piloto , Valor Predictivo de las Pruebas , Impresión Tridimensional , Estudios Prospectivos , Dosis de Radiación , Exposición a la Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Radiografía Intervencional/efectos adversos , Reproducibilidad de los Resultados , Factores de Riesgo , Factores de Tiempo , Tomografía Computarizada por Rayos X/efectos adversos , Resultado del Tratamiento , Ultrasonografía Intervencional/efectos adversos
8.
Catheter Cardiovasc Interv ; 90(2): 321-328, 2017 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-28185392

RESUMEN

BACKGROUND: Degenerated surgical mitral valve repairs or surgical prostheses are currently being treated with transcatheter mitral valve replacement (TMVR). We report the procedural and mid-term assessment of thirteen cases. METHODS: From 12/2013 to 12/2015, 13 consecutive patients with degenerated mitral valve repair or valve replacement were treated. Patients were assessed for mitral valve academic valve consortium (MVARC) defined outcomes. RESULTS: Immediate procedural MVARC defined technical success was 92%. At 30 days MVARC device and procedure success were 61% and 84%, respectively. Mean follow-up was 150 days [IQR 40-123 days]. There were 2 late major adverse outcomes, a noncardiac related death (628 days) and a stroke (382 days). The mean mitral gradient decreased from 9.5 ± 3.4 to 5.5 ± 2.6 mm Hg (P < 0.01). Three patients were found to have high gradients, two presented with heart failure while another patient was found to have reduced leaflet motion and abnormal thickening postprocedure. The two patients with heart failure were treated with enoxaparin, which caused subsequent resolution of increased valve gradients in one patient. The other patient could not tolerate prolonged treatment from anticoagulation due to gastrointestinal bleeding. Three of 13 patients were treated with dual-antiplatelet therapy and were suspected to have valve thrombosis. CONCLUSION: Thrombotic related dysfunction post-TMVR occurred in 15% (2/13) of patients and one patient had abnormal leaflet thickening that may have been thrombus related. Dual-antiplatelet therapy was used in all 3 cases suggesting the possible need for oral anticoagulation postmitral valve-in-valve therapy. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Mitral/cirugía , Trombosis/etiología , Anciano , Anciano de 80 o más Años , Anticoagulantes/administración & dosificación , Anticoagulantes/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidad , Ecocardiografía Transesofágica , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemorragia/inducido químicamente , Humanos , Masculino , Michigan , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Inhibidores de Agregación Plaquetaria/administración & dosificación , Inhibidores de Agregación Plaquetaria/efectos adversos , Falla de Prótesis , Radiografía Intervencional , Estudios Retrospectivos , Factores de Riesgo , Trombosis/tratamiento farmacológico , Trombosis/mortalidad , Trombosis/fisiopatología , Factores de Tiempo , Tomografía Computarizada por Rayos X , Insuficiencia del Tratamiento
9.
Catheter Cardiovasc Interv ; 87(4): E166-71, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26255796

RESUMEN

OBJECTIVE/BACKGROUND: As smaller TAVR delivery systems emerge we sought to identify differences in vascular access use. METHODS: We analyzed all patients who had undergone TAVR in a single-center from March 2012 to May 2014. We identified all patients who had undergone nonfemoral TAVR and reviewed their femoral dimensions using CT imaging taking into vascular pathology and minimal lumen diameter (MLD). We then identified those patients in whom a smaller delivery system could have been used if such technology was available at that time. RESULTS: In total 208 consecutive TAVRs were performed, 129 cases using femoral arterial access and 75 cases using non-femoral access; 28 transapical, 27 transcaval, 12 transaortic, and 8 via an antegrade transseptal venous approach. Of the 75 nonfemoral access cases, 63 were completed using commercially available first-generation valves (Sapien Valve) and 12 using second-generation valves under research protocols (Sapien XT Valve). Of the 63 cases performed via a non-femoral route using a first generation valve, 31 cases could have been approached via a transfemoral (TF) route using second-generation delivery systems; and 48 cases could have been approached via a TF route using third generation delivery systems (S3 Valve). Of the 12 cases performed via a nonfemoral route using a second-generation valve, 4 cases could have been approached via a TF route using a third-generation delivery system. In total, only 11% of patients undergoing TAVR could not accommodate smaller second and third generation devices. CONCLUSIONS: As second and third generation devices become commercially available, we anticipate that 89% of cases will be preformed using a TF approach.


Asunto(s)
Válvula Aórtica , Cateterismo Cardíaco/estadística & datos numéricos , Cateterismo Periférico/estadística & datos numéricos , Arteria Femoral , Enfermedades de las Válvulas Cardíacas/terapia , Implantación de Prótesis de Válvulas Cardíacas/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/instrumentación , Cateterismo Periférico/instrumentación , Angiografía por Tomografía Computarizada , Diseño de Equipo , Femenino , Arteria Femoral/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/diagnóstico , Prótesis Valvulares Cardíacas/estadística & datos numéricos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Michigan , Persona de Mediana Edad , Estudios Retrospectivos , Centros de Atención Terciaria , Resultado del Tratamiento , Dispositivos de Acceso Vascular/estadística & datos numéricos
10.
J Healthc Manag ; 58(3): 173-85; discussion 185-6, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23821897

RESUMEN

The Resource-Based Relative Value Scale is widely used to measure healthcare provider productivity and to set payment standards. The scale, however, is limited in its assessment of pre- and postservice work and other potentially non-revenue-generating healthcare services, what we have termed service-valued activity (SVA). In an attempt to quantify SVA, we conducted a time and motion study of providers to assess their productivity in inpatient and outpatient settings. Using the Standard Time and Motion Procedures checklist as a methodological guide, we provided personal digital assistants (PDAs) that were prepopulated with 2010 Current Procedural Terminology codes to 19 advanced practice providers (APPs). The APPs were instructed to identify their location and activity each time the PDA randomly alarmed. The providers collected data for 3 to 5 workdays, and those data were separated into revenue-generating services (RGSs) and SVAs. Multiple inpatient and outpatient departments were assessed. The inpatient APPs spent 61.6 percent of their time on RGSs and 35.1 percent on SVAs. Providers in the outpatient settings spent 59.0 percent of their time on RGSs and 38.2 percent on SVAs. This time and motion study demonstrated an innovative method and tool for the quantification and analysis of time spent on revenue- and non-revenue-generating services provided by healthcare professionals. The new information derived from this study can be used to accurately document productivity, determine clinical practice patterns, and improve deployment strategies of healthcare providers.


Asunto(s)
Evaluación del Rendimiento de Empleados/economía , Enfermeras Practicantes/economía , Asistentes Médicos/economía , Estudios de Tiempo y Movimiento , Centros Médicos Académicos/economía , Lista de Verificación , Computadoras de Mano , Recolección de Datos/métodos , Eficiencia Organizacional , Departamentos de Hospitales/economía , Humanos , Michigan , Pautas de la Práctica en Enfermería/economía , Pautas de la Práctica en Medicina/economía , Escalas de Valor Relativo
11.
Nurs Clin North Am ; 58(3): 357-378, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37536786

RESUMEN

Over the last few decades, there have been dramatic advances in the understanding of the mechanisms of valvular heart disease and development of percutaneous treatment options. These innovations have resulted in the need for a multidisciplinary heart team approach for quality patient outcomes, a team in which nursing is an integral member. This update provides an overview of the major valve diseases, current guideline recommendations, catheter-based treatment options and key elements of nursing care: physical examination, diagnostic testing, pre- and post-procedure care protocols, and patient education elements.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Enfermeras y Enfermeros , Humanos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/cirugía
12.
JACC Adv ; 2(1): 100160, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38939019

RESUMEN

Cardiovascular multidisciplinary heart teams (MDHTs) have evolved significantly over the past decade. These teams play a central role in the treatment of a wide array of cardiovascular diseases affecting interventional cardiology, cardiac surgery, interventional imaging, advanced heart failure, adult congenital heart disease, cardio-oncology, and cardio-obstetrics. To meet the specific needs of both patients and heart programs, the composition and function of cardiovascular MDHTs have had to adapt and evolve. Although lessons have been learned from multidisciplinary cancer care, best practices for the operation of cardiovascular MDHTs have yet to be defined, and the evidence base supporting their effectiveness is limited. This expert panel review discusses the history and evolution of cardiovascular MDHTs, their composition and role in treating patients across a broad spectrum of disciplines, basic tenets for successful operation, and the future challenges facing them.

13.
J Am Assoc Nurse Pract ; 34(6): 844-849, 2022 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-35472192

RESUMEN

BACKGROUND: As transcatheter aortic valve replacement (TAVR) becomes a preferred treatment option for patients with aortic valve stenosis, and demand for TAVR increases, it is imperative that length of stay (LOS) is reduced while maintaining safety and effectiveness. LOCAL PROBLEM: As TAVR procedures have become less invasive and more streamlined, current protocols have not been updated to reflect today's postprocedure requirements. METHODS: The next-day discharge (NDD) protocol was established using available literature. A convenience sample was evaluated for NDD protocol inclusion during aortic multidisciplinary team conference using predetermined inclusion and exclusion criteria. Length of stay for NDD protocol participants was compared with LOS from a retrospective convenience sample of patients undergoing TAVR in the time frame mirroring NDD protocol initiation of the year prior. INTERVENTIONS: Patients meeting inclusion criteria were enrolled in the NDD protocol with a goal of discharge to home on postprocedural day 1 by 2:00 p.m. The NDD protocol included preprocedure expectation setting, prescheduled same-day postprocedure imaging, and discharge priority on postprocedure day 1. RESULTS: There is a significant difference in LOS between the NDD eligible retrospective and prospective groups. The prospective group has a significantly lower LOS than the retrospective group (M = 1.6 vs 2.1, respectively; p = .0454). CONCLUSIONS: An NDD protocol can help reduce LOS after TAVR in appropriately selected patients. Further protocol revision will be required to optimize LOS outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Tiempo de Internación , Estudios Prospectivos , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
14.
J Am Geriatr Soc ; 70(12): 3378-3389, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35945706

RESUMEN

BACKGROUND: Little is known about policies and practices for patients undergoing Transcatheter Aortic Valve Replacement (TAVR) who have a documented preference for Do Not Resuscitate (DNR) status at time of referral. We investigated how practices across TAVR programs align with goals of care for patients presenting with DNR status. METHODS: Between June and September 2019, we conducted semi-structured interviews with TAVR coordinators from 52/73 invited programs (71%) in Washington and California (TAVR volume > 100/year:34%; 50-99:36%; 1-50:30%); 2 programs reported no TAVR in 2018. TAVR coordinators described peri-procedural code status policies and practices and how they accommodate patients' goals of care. We used data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry, stratified by programs' DNR practice, to examine differences in program size, patient characteristics and risk status, and outcomes. RESULTS: Nearly all TAVR programs (48/50: 96%) addressed peri-procedural code status, yet only 26% had established policies. Temporarily rescinding DNR status until after TAVR was the norm (78%), yet time frames for reinstatement varied (38% <48 h post-TAVR; 44% 48 h-to-discharge; 18% >30 days post-discharge). For patients with fluctuating code status, no routine practices for discharge documentation were well-described. No clinically substantial differences by code status practice were noted in Society of Thoracic Surgeons Predicted Risk of Mortality risk score, peri-procedural or in-hospital cardiac arrest, or hospice disposition. Six programs maintaining DNR status recognized TAVR as a palliative procedure. Among programs categorically reversing patients' DNR status, the rationale for differing lengths of time to reinstatement reflect divergent views on accountability and reporting requirements. CONCLUSIONS: Marked heterogeneity exists in management of peri-procedural code status across TAVR programs, including timeframe for reestablishing DNR status post-procedure. These findings call for standardization of DNR decisions at specific care points (before/during/after TAVR) to ensure consistent alignment with patients' health-related goals and values.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estados Unidos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Cuidados Posteriores , Medición de Riesgo , Resultado del Tratamiento , Alta del Paciente , Factores de Riesgo , Sistema de Registros , Políticas , Válvula Aórtica/cirugía
15.
Cardiovasc Revasc Med ; 27: 7-13, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-32741589

RESUMEN

BACKGROUND: Detailed procedural analysis and long-term data is limited for coronary protection (CP) during transcatheter aortic valve replacement (TAVR) for patients with high anatomical risk for coronary occlusion (CO). We aim to assess the procedural and mid-term outcomes of CP during TAVR. METHODS: We retrospectively analyzed patients who underwent TAVR at Henry Ford Hospital, USA from January 2015 to August 2019 and identified those considered at risk of CO and underwent pre-emptive CP with or without subsequent "chimney" stenting (i.e. coronary stenting with intentional protrusion into the aorta). Procedural features, immediate and mid-term clinical outcomes were reviewed. RESULTS: Twenty-five out of 1166 (2.1%) patients underwent TAVR with CP, including 10 (40%) valve-in-valve procedures. Twenty-eight coronary arteries (Left: n = 11, Right: n = 11; Left + Right: n = 3) were protected. Eleven coronaries (39.3%) were electively "chimney"-stented due to angiographic evidence of coronary impingement (63.6%), tactile resistance while withdrawing stent (27.3%) and electrocardiogram change (9.1%). Twenty-four patients (24/25, 96%) had successful TAVR without CO. Procedure-related complications included stent-balloon entrapment (n = 1), stent entrapment (n = 1) and occlusive distal stent edge dissection (n = 1). After a mean follow-up of 19.1 months, there was 1 cardiac death but no target vessel re-intervention or myocardial infarction. CONCLUSIONS: Our study found that angiographic evidence of coronary impingement (63.6%) was the most common reason for stent deployment during TAVR with CP. The mid-term clinical outcome of CP with TAVR was favorable.


Asunto(s)
Estenosis de la Válvula Aórtica , Oclusión Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/cirugía , Humanos , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
17.
J Am Coll Cardiol ; 76(20): 2391-2411, 2020 11 17.
Artículo en Inglés | MEDLINE | ID: mdl-33190683

RESUMEN

Consensus regarding a reasonable strategy to manage cardiac conduction disturbances after transcatheter aortic valve replacement (TAVR) has been elusive. This is due to the absence of adequately powered, randomized controlled trials; the often transient nature of the conduction disturbances; evolving technologies; and the interplay of cardiology subspecialties involved. In the absence of high-quality trials, numerous practice styles have been developed, and prolonged observation, electrophysiological testing, and pre-emptive pacemaker implantation have been described. Although the 2013 European Society of Cardiology guidelines address pacing post-TAVR, they do not provide in-depth discussion of this topic. Furthermore, a summary and proposed strategy for this problem have not been published by cardiovascular societies in the United States, despite an interest in establishing best practices in TAVR, valvular heart disease, and cardiovascular implantable electrical devices. This document reviews existing data and experience regarding the management of conduction disturbances after TAVR and proposes an evidence-based expert consensus decision pathway for their management. Where evidence is lacking or insufficient, the recommendations herein are based on expert opinion.


Asunto(s)
Enfermedad de la Válvula Aórtica/cirugía , Trastorno del Sistema de Conducción Cardíaco/terapia , Complicaciones Posoperatorias/terapia , Reemplazo de la Válvula Aórtica Transcatéter , Técnicas de Apoyo para la Decisión , Humanos
18.
JACC Cardiovasc Interv ; 13(12): 1484-1488, 2020 06 22.
Artículo en Inglés | MEDLINE | ID: mdl-32250751

RESUMEN

The coronavirus disease-2019 (COVID-19) pandemic has strained health care resources around the world, causing many institutions to curtail or stop elective procedures. This has resulted in an inability to care for patients with valvular and structural heart disease in a timely fashion, potentially placing these patients at increased risk for adverse cardiovascular complications, including CHF and death. The effective triage of these patients has become challenging in the current environment as clinicians have had to weigh the risk of bringing susceptible patients into the hospital environment during the COVID-19 pandemic against the risk of delaying a needed procedure. In this document, the authors suggest guidelines for how to triage patients in need of structural heart disease interventions and provide a framework for how to decide when it may be appropriate to proceed with intervention despite the ongoing pandemic. In particular, the authors address the triage of patients in need of transcatheter aortic valve replacement and percutaneous mitral valve repair. The authors also address procedural issues and considerations for the function of structural heart disease teams during the COVID-19 pandemic.


Asunto(s)
Betacoronavirus , Procedimientos Quirúrgicos Cardiovasculares , Infecciones por Coronavirus/epidemiología , Cardiopatías/cirugía , Selección de Paciente , Neumonía Viral/epidemiología , Triaje , Procedimientos Quirúrgicos Ambulatorios , COVID-19 , Infecciones por Coronavirus/prevención & control , Infecciones por Coronavirus/transmisión , Humanos , Pandemias/prevención & control , Neumonía Viral/prevención & control , Neumonía Viral/transmisión , Derivación y Consulta , SARS-CoV-2
19.
JACC Cardiovasc Interv ; 9(22): 2329-2340, 2016 11 28.
Artículo en Inglés | MEDLINE | ID: mdl-27884358

RESUMEN

OBJECTIVES: The aim of this study was to examine the impact of 3-dimensional (3D) computed tomographic (CT) guided procedural planning for left atrial appendage (LAA) occlusion on the early operator WATCHMAN learning curve. BACKGROUND: Traditional WATCHMAN implantation is dependent on 2-dimensional transesophageal echocardiographic (TEE) sizing and intraprocedural guidance. METHODS: LAA occlusion with the WATCHMAN device was performed in 53 patients. Pre-procedural case plans were generated from CT studies with recommended device size, catheter selection, and C-arm angle for deployment. RESULTS: All 53 patients underwent successful LAA occlusion with the WATCHMAN. Three-dimensional CT LAA maximal-width sizing was 2.7 ± 2.2 mm and 2.3 ± 3.0 mm larger than 2-dimensional and 3D TEE measurements, respectively (p ≤ 0.0001). By CT imaging, device selection was 100% accurate. There were 4 peri-WATCHMAN leaks (<4.5 mm) secondary to accessory LAA pedunculations. By 2-dimensional TEE maximal-width measurements alone, 62.3% (33 of 53) would have required larger devices. Using 3D TEE maximal-width measurements, 52.8% of cases (28 of 53) would have required larger devices. Three-dimensional TEE length would have inappropriately excluded 10 patients from WATCHMAN implantation. Compared with the average of 1.8 devices used per implantation attempt in PROTECT AF (WATCHMAN Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) (82% success rate), the present site averaged 1.245 devices per implantation attempt (100% success rate). There were no intraprocedural screen failures and no major adverse cardiac events. CONCLUSIONS: Three-dimensional CT image case planning provides a comprehensive and customized patient-specific LAA assessment that appears to be accurate and may possibly facilitate reducing the early WATCHMAN implantation learning curve.


Asunto(s)
Apéndice Atrial/diagnóstico por imagen , Cateterismo Cardíaco/instrumentación , Competencia Clínica , Imagenología Tridimensional , Curva de Aprendizaje , Interpretación de Imagen Radiográfica Asistida por Computador , Dispositivo Oclusor Septal , Terapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Puntos Anatómicos de Referencia , Cateterismo Cardíaco/efectos adversos , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Femenino , Humanos , Masculino , Michigan , Valor Predictivo de las Pruebas , Diseño de Prótesis , Reproducibilidad de los Resultados , Resultado del Tratamiento
20.
J Am Coll Cardiol ; 65(19): 2118-36, 2015 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-25975476

RESUMEN

The mission of the American College of Cardiology is "to transform cardiovascular care and improve heart health." Cardiovascular team-based care is a paradigm for practice that can transform care, improve heart health, and help meet the demands of the future. One strategic goal of the College is to help members successfully transition their clinical practices to the future, with all its complexity, challenges, and opportunities. The ACC's strategic plan is aligned with the triple aim of improved care, improved population health, and lower costs per capita. The traditional understanding of quality, access, and cost is that you cannot improve one component without diminishing the others. With cardiovascular team-based care, it is possible to achieve the triple aim of improving quality, access, and cost simultaneously to also improve cardiovascular health. Striving to serve the best interests of patients is the true north of our guiding principles. Cardiovascular team-based care is a model that can improve care coordination and communication and allow each team member to focus more on the quality of care. In addition, the cardiovascular team-based care model increases access to cardiovascular care and allows expansion of services to populations and geographic areas that are currently underserved. This document will increase awareness of the important components of cardiovascular team-based care and create an opportunity for more discussion about the most creative and effective means of implementing it. We hope that this document will stimulate further discussions and activities within the ACC and beyond about team-based care. We have identified areas that need improvement, specifically in APP education and state regulation. The document encourages the exploration of collaborative care models that should enable team members to optimize their education, training, experience, and talent. Improved team leadership, coordination, collaboration, engagement, and efficiency will enable the delivery of higher-value care to the betterment of our patients and society.


Asunto(s)
Cardiología/normas , Enfermedades Cardiovasculares/terapia , Personal de Salud/normas , Política de Salud , Grupo de Atención al Paciente/normas , Guías de Práctica Clínica como Asunto , Sociedades Médicas , Conducta Cooperativa , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA