Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Ann Surg ; 275(5): 947-954, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33273356

RESUMEN

OBJECTIVE: We evaluated the morbidity and mortality after anatomical hepatectomy with the Glissonean pedicle approach, and long-term outcomes in relation to the morbidity in patients with hepatocellular carcinoma (HCC). SUMMARY BACKGROUND DATA: The mortality, morbidity, and long-term outcomes were evaluated retrospectively. METHODS: A total of 1953 patients with HCC underwent various anatomical hepatectomies with the Glissonean pedicle approach between 1985 and 2014. The mortality (30-day and 90-day) and morbidity (Clavien-Dindo class Ilia or higher) were evaluated among six 5-year eras (1985-1989, 1990-1994, 1995-1999, 2000-2004, 2005-2009, 2010-2014). RESULTS: A total of 460 patients (24%) showed morbidity, and the overall 30-day and 90-day mortality rates were 1.8% and 3.3%, respectively. The 30-day (3.9%, 3.0%, 1.8%, 1.3%, 0.3%, 0.5%: P = 0.0074) and 90-day mortality (6.0%, 4.3%, 3.8%, 2.8%, 2.2%, 1.4%: P = 0.0445) significantly improved over the eras. Blood loss >2 L (odds ratio: 11.808, P = 0.0244) was an independent risk factor for 30-day mortality, and blood loss >2 L (odds ratio: 4.046, P = 0.0271) and bile leakage (odds ratio: 2.122, P = 0.0078) were independent risk factors for 90-day mortality on multivariate analysis. Morbidity was significant independent prognostic factors for overall survival (relative risk: 2.129, P < 0.0001) and recurrence-free survival (relative risk: 1.299, P < 0.0001) in patients with HCC. CONCLUSIONS: Anatomical hepatectomy with the Glissonean pedicle approach was achieved safely in patients with HCC. For more safety and longer survival, blood loss, bile leakage, and morbidity should be reduced. Longterm outcomes after anatomical hepatectomy with the Glissonean pedicle approach in patients with HCC have been improved over 30 years with gradually less mortality and morbidity due to decreases in blood loss >2 L and bile leakage.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/etiología , Carcinoma Hepatocelular/cirugía , Hepatectomía/efectos adversos , Humanos , Neoplasias Hepáticas/patología , Morbilidad , Estudios Retrospectivos
2.
Epilepsy Behav ; 118: 107912, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33744796

RESUMEN

Criminal behavior by people with epilepsy (PWE) has often been discussed. However, there are limited studies on criminal victimization of PWE-in particular, how such victimizations occur. We identified criminal cases involving victims with epilepsy using databases containing criminal judgments and found 16 such cases between 1990 and 2019. Seven were homicide cases, including four filicide cases. In the four filicide cases, all the perpetrators had the intention of homicide-suicide; all the victims had intellectual disabilities or cerebral palsy; two of these victims had acted violently toward the family; and two mothers who perpetrated the crime against the victims had depression. It seemed that the comorbidities and problem behaviors of the victims were more strongly related to serious crimes by family caregivers than the epilepsy itself. To prevent victimization caused by family caregivers, reducing their stress levels is important. Defendants sometimes argued against objective evidence of a crime, claiming that epileptic seizure of PWE caused or was related to the death of victims. Legal and medical professionals involved in determining the manner of death need careful evaluation when sudden deaths of PWE occur.


Asunto(s)
Víctimas de Crimen , Criminales , Epilepsia , Homicidio , Humanos , Japón/epidemiología , Juicio
3.
Blood Press Monit ; 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38774982

RESUMEN

PURPOSE: The performance of the Omron HEM-7372T1-AZAZ (BP5460) in monitoring blood pressure (BP) in the upper arm was validated in accordance with the International Organization for Standardization (ISO) 81060-2:2018 (E) and amendment (Amd)1:2020 protocol. METHODS: The device was used to assess 98 participants who fulfilled the inclusion criteria, including the range of arm circumference and systolic and diastolic BP, in accordance with the protocol. Data validation and analysis were performed according to the manufacturer's instructions. RESULTS: In the ISO validation procedure (criterion 1), the mean ± SD of the differences between test device readings and reference BP was 0.3 ±â€…6.17/3.6 ±â€…5.26 mmHg (systolic/diastolic). These data fulfilled the ISO requirements of ≤5±≤8 mmHg. The mean differences between the observer measurements and Omron HEM-7372T1-AZAZ (BP5460) readings were 0.3 ±â€…4.82 mmHg for systolic BP and 3.6 ±â€…4.78 mmHg for diastolic BP, fulfilling criterion 2 with SD values of ≤6.95 for SBP and ≤5.89 for DBP. Therefore, two ISO criteria were fulfilled. CONCLUSION: The Omron HEM-7372T1-AZAZ BP monitor fulfilled the requirements of the ISO validation standard. This device can be recommended for home BP measurements in the general population.

4.
Technol Health Care ; 2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-39093088

RESUMEN

BACKGROUND: Blood pressure (BP) naturally undergoes fluctuations and variations, particularly during anesthesia administration during surgery, hemodialysis, upper and lower gastrointestinal endoscopy, exercise testing, arterial and venous catheterization, and rehabilitation. These changes in BP may lead to life-threatening events. OBJECTIVES: The performance of the Omron HBP-M4500 device in monitoring blood pressure (BP) in the upper arm was validated according to the International Organization for Standardization (ISO) 81060-2:2018+amendment (Amd) 1:2020 protocol. METHODS: The device was used to assess 113 participants in the inflation mode, and 107 participants in the deflation mode. All the patients fulfilled the inclusion criteria, including the arm circumference range and systolic and diastolic BP levels, outlined in the protocol. Data validation and analysis were performed according to the manufacturer's instructions. RESULTS: In criterion 1, the mean ± standard deviation (SD) values of the differences between the test device and reference BP were -0.6 ± 5.80/2.8 ± 6.78 mmHg (systolic/diastolic) and -1.0 ± 5.35/3.2 ± 6.52 mmHg for the inflation and deflation modes, respectively. These data fulfilled the ISO81060-2:2018+Amd1:2020 requirements of ⩽ 5 ±â£â©½ 8 mmHg. In criterion 2, the differences were -0.6 ± 4.44/2.8 ± 6.26 and -1.0 ± 3.84/3.2 ± 6.09 mmHg for the inflation and deflation modes, respectively, fulfilling criterion 2 with SD values of ⩽ 6.91 and ⩽ 6.87 for systolic BP and ⩽ 6.34 and ⩽ 6.14 for diastolic BP in the inflation and deflation modes, respectively. These two criteria were fulfilled in both studies. CONCLUSION: The Omron HBP-M4500 device, either in inflation or deflation mode, fulfilled the criteria outlined in the ISO protocol. Therefore, this device is valuable for BP measurement in clinical and hospital settings.

5.
Vasc Health Risk Manag ; 20: 333-339, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39070216

RESUMEN

Purpose: The performance of Omron HEM-1026 (HCR-1901T2 / HCR-1902T2) for monitoring blood pressure (BP) in the upper arm was validated in accordance with the International Organization for Standardization (ISO) 81060-2:2018+amendment (Amd)1:2020 protocol. Methods: The device was assessed in 101 participants who fulfilled the inclusion criteria, including arm circumference range and systolic and diastolic BP provided by the protocol. Data validation and analysis were performed according to the manufacturer's instructions. Results: In the ISO 81060-2:2018+Amd 1:2020 validation procedure (criterion 1), the mean ± standard deviation (SD) of the differences between the test device and reference BP was -2.1 ± 7.24/-0.6 ± 5.63 mmHg (systolic/diastolic). These data fulfilled the ISO81060-2:2018+Amd1:2020 requirement of ≤5±≤8 mmHg. The mean differences between the two observers and Omron HEM-1026 were -2.1 ± 5.71 mmHg for systolic BP and -0.6 ± 4.81 mmHg for diastolic BP, fulfilling criterion 2 with an SD of ≤ 6.62 for systolic BP and ≤ 6.91 for diastolic BP. The two ISO criteria were fulfilled. Conclusion: The Omron HEM-1026 BP monitor fulfilled the requirements of the ISO 81060-2:2018+Amd 1:2020 validation standard and can be recommended for home BP measurements in the general population.


Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial , Presión Sanguínea , Diseño de Equipo , Valor Predictivo de las Pruebas , Humanos , Reproducibilidad de los Resultados , Masculino , Femenino , Persona de Mediana Edad , Anciano , Monitoreo Ambulatorio de la Presión Arterial/instrumentación , Monitoreo Ambulatorio de la Presión Arterial/normas , Adulto , Monitores de Presión Sanguínea/normas , Variaciones Dependientes del Observador , Extremidad Superior/irrigación sanguínea
6.
Hypertens Res ; 47(6): 1576-1587, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38548911

RESUMEN

The nocturnal blood pressure (BP) surge in seconds (sec-surge) is defined as a brief, acute transient BP elevation over several tens of seconds, triggered by obstructive sleep apnea (OSA) and sympathetic hyperactivity. Sec-surge imposes a significant strain on the cardiovascular system, potentially triggering cardiovascular events. Quantitative evaluation of sec-surge level could be valuable in assessing cardiovascular risks. To accurately measure the detailed sec-surge, including its shape as BP rises and falls, we developed a beat-by-beat (BbB) BP monitoring device using tonometry. In addition, we developed an automatic sec-surge detection algorithm to help identify sec-surge cases in the overnight BbB BP data. The device and algorithm successfully detected sec-surges in patients with OSA. Our results demonstrated that sec-surge was associated with left ventricular hypertrophy and arterial stiffness independently of nocturnal BP level or variability. Sec-surge would be worth monitoring for assessing cardiovascular risks, in addition to nocturnal BP level. Nocturnal blood pressure (BP) surge in seconds (sec-surge) places heavy load on the cardiovascular system and can trigger cardiovascular events. To identify sec-surges, we developed a beat-by-beat BP monitoring device and a sec-surge detection algorithm. Furthermore, sec-surge was more related to cardiovascular risks than conventional nocturnal BP parameters.


Asunto(s)
Algoritmos , Monitoreo Ambulatorio de la Presión Arterial , Presión Sanguínea , Humanos , Presión Sanguínea/fisiología , Monitoreo Ambulatorio de la Presión Arterial/instrumentación , Monitoreo Ambulatorio de la Presión Arterial/métodos , Ritmo Circadiano/fisiología , Apnea Obstructiva del Sueño/fisiopatología , Apnea Obstructiva del Sueño/diagnóstico , Hipertensión/fisiopatología , Hipertensión/diagnóstico , Determinación de la Presión Sanguínea/instrumentación , Determinación de la Presión Sanguínea/métodos
7.
J Clin Hypertens (Greenwich) ; 25(4): 388-392, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36945820

RESUMEN

Nocturnal blood pressure (BP) surge in seconds (sec-surge), which is characterized as acute transient BP elevation over several tens of seconds is induced by obstructive sleep apnea (OSA) and OSA-related sympathetic hyperactivity. The authors assessed the relationship between sec-surge and arterial stiffness in 34 nocturnal hypertensive patients with suspected OSA (mean age 63.9 ± 12.6 years, 32.4% female). During the night, they had beat-by-beat (BbB) BP and cuff-oscillometric BP measurements, and brachial-ankle pulse wave velocity (baPWV) was assessed as an arterial stiffness index. Multiple linear regression analysis revealed that the upward duration (UD) of sec-surge was significantly associated with baPWV independently of nocturnal oscillometric systolic BP variability (ß = .365, p = .046). This study suggests that the UD of sec-surge, which can only be measured using a BbB BP monitoring device, may be worth monitoring in addition to nocturnal BP level.


Asunto(s)
Hipertensión , Apnea Obstructiva del Sueño , Rigidez Vascular , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Presión Sanguínea/fisiología , Índice Tobillo Braquial , Análisis de la Onda del Pulso , Apnea Obstructiva del Sueño/complicaciones , Apnea Obstructiva del Sueño/diagnóstico , Monitoreo Ambulatorio de la Presión Arterial
8.
J Hypertens ; 41(5): 811-818, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36883464

RESUMEN

OBJECTIVE: Automated cuff blood pressure (BP) devices are widely used for ambulatory, home, and office BP measurement. However, an automated device, which is accurate in the general adult population may be inaccurate in some special populations. A 2018 Collaborative Statement by the US Association for the Advancement of Medical Instrumentation, the European Society of Hypertension, and the International Organization for Standardization (ISO) considered three special populations requiring separate validation (age <3 years, pregnancy, and atrial fibrillation). An ISO Task Group was appointed to identify evidence for additional special populations. METHOD: Evidence on potential special populations was identified from the STRIDE BP database, which performs systematic PubMed searches for published validation studies of automated cuff BP monitors. Devices that passed in a general population, but failed in potential special populations were identified. RESULTS: Of 338 publications (549 validations, 348 devices) in the STRIDE BP database, 29 publications (38 validations, 25 devices) involved 4 potential special populations: (i) age 12-18 years: 3 of 7 devices failed but passed in a general population; (ii) age more than 65 years: 1 of 11 devices failed but passed in a general population; (iii) diabetes type-2: 4 devices (all passed); (iv) chronic kidney disease: 2 of 7 devices failed but passed in a general population. CONCLUSION: Some evidence suggest that the automated cuff BP devices may have different accuracy in adolescents and in patients with chronic kidney disease than in the general population. More research is needed to confirm these findings and investigate other potential special populations.


Asunto(s)
Hipertensión , Insuficiencia Renal Crónica , Adulto , Femenino , Embarazo , Humanos , Adolescente , Preescolar , Niño , Anciano , Monitores de Presión Sanguínea , Determinación de la Presión Sanguínea , Hipertensión/diagnóstico , Estándares de Referencia , Presión Sanguínea
9.
J Clin Hypertens (Greenwich) ; 24(3): 271-282, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34935266

RESUMEN

Nocturnal blood pressure (BP) surge in seconds (sec-surge), which is characterized as acute transient BP elevation over several tens of seconds, could be a predictor of target organ damage. However, it is not clear that the severity of sec-surge is different between sec-surges induced by sleep apnea (SA) (apnea/hypopnea detected by polysomnography (PSG) or oxygen desaturation) and those induced by non-SA factors (rapid eye movement, micro arousal, etc.), and sec-surge variables associate with left ventricular hypertrophy (LVH) independently of conventional BP variables. The authors assessed these points with 41 patients (mean age 63.2±12.6 years, 29% female) who underwent full PSG, beat-by-beat (BbB) BP, and cuff-oscillometric BP measurement during the night. All patients were included for the analysis comparing sec-surge severity between inducing factors (SA and non-SA factors). There were no significant differences in the number of sec-surges/night between SA-related sec-surges and non-SA-related sec-surges (19.5±26.0 vs. 16.4±29.8 events/night). There were also no significant differences in the peak of sec-surges, defined as the maximum systolic BPs (SBPs) in each sec-surge, between SA-related sec-surges and non-SA-related sec-surges (148.2±18.5 vs. 149.3±19.2 mm Hg). Furthermore, as a result of multiple regression analysis (n = 18), the peak of sec-surge was significantly and strongly associated with the left ventricular mass index (standardized ß = 0.62, p = .02), compared with the mean nocturnal SBPs measured by oscillometric method (ß = -0.04, p = .87). This study suggests that peak of sec-surge could be a better predictor of LVH compared to parameters derived from regular nocturnal oscillometric SBP.


Asunto(s)
Hipertensión , Síndromes de la Apnea del Sueño , Apnea Obstructiva del Sueño , Anciano , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea , Monitoreo Ambulatorio de la Presión Arterial/métodos , Ritmo Circadiano/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polisomnografía , Síndromes de la Apnea del Sueño/complicaciones
10.
Cancer Diagn Progn ; 2(2): 160-166, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35399165

RESUMEN

Background/Aim: The optimal indication of hepatectomy with adjuvant therapy for intrahepatic cholangiocarcinoma (ICC) has not been evaluated in detail. Patients and Methods: We retrospectively studied 224 patients with ICC who underwent hepatectomy between 2000 and 2019. Prognostic factors for overall survival (OS) were evaluated by univariate and multivariate analysis. A total of 127 patients were treated with adjuvant therapy (62 patients with chemotherapy and 65 patients with immunotherapy) after hepatectomy, and 97 patients were treated with hepatectomy alone. Results: Intrahepatic metastasis (IM), lymph node metastasis (LNM) of ICC, adjuvant chemotherapy, and adjuvant immunotherapy were significant prognostic factors for OS on multivariate analysis. In 127 patients with neither IM nor LNM, the 5-year OS rate was significantly higher in 36 patients with adjuvant chemotherapy (81%) and in 34 patients with adjuvant immunotherapy (68%) than in 57 patients with hepatectomy alone (45%). Conclusion: The absence of IM or LNM is the optimal indication for hepatectomy with adjuvant therapy in patients with ICC.

11.
No Shinkei Geka ; 39(3): 263-8, 2011 Mar.
Artículo en Japonés | MEDLINE | ID: mdl-21372335

RESUMEN

We studied the incidence of postoperative infection related to CSF leakage and anosmia in basal interhemispheric approach (BIH). Between April, 1990 to March, 2009, 142 cases of anterior communicating (Acom) aneurysm including both unruptured and ruptured have been treated by clipping surgery using BIH. We retrospectively obtained clinical informations from medical records and video records about infectious complications, CSF leakage of cerebrospinal fluid (CSF), olfactory dysfunction and intraoperative findings of damage to the olfactory nerve. In most cases (139 patients, 97%), frontal sinus were opened at craniotomy. Of all, CSF rinorrhea occurred in 4 cases (2.8%), and meningitis in 6 cases. There was only one patient who sufferd from meningitis due to CSF rinorrhea. All that patients recovered completely without deficit. Anosmia occurred in 6 cases (4.2%), and intraoperative injuries in 4 cases (2.8%). There was only one patient in whom anosmia was consistent with nerve injury. In conclusion, BIH is an appropriate procedure for infection risk control in Acom aneurysm surgery. It is difficult to avoid olfactory dysfunction completely, even if olfactory nerves are preserved in form.


Asunto(s)
Rinorrea de Líquido Cefalorraquídeo/etiología , Aneurisma Intracraneal/cirugía , Procedimientos Neuroquirúrgicos/métodos , Trastornos del Olfato/etiología , Adulto , Anciano , Aneurisma Roto/cirugía , Arteria Cerebral Anterior/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Traumatismos del Nervio Olfatorio , Complicaciones Posoperatorias , Estudios Retrospectivos
12.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 5455-5458, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34892360

RESUMEN

Blood pressure (BP) variability (BPV) is one of the important risk factors of cardiovascular (CV) disease. Particularly, nocturnal short-term BPV, characterized as acute transient BP elevation over several tens of seconds (BP surge), can trigger CV events. To accurately detect BP surge, it is necessary to monitor BP at each heartbeat. Although continuous BP monitors have been developed and validated, they are too large to measure beat-by-beat (BbB) BP at home. Therefore, we developed a small and lightweight BbB BP monitoring device (BbB device) based on tonometry. In this study, the BbB device was evaluated in terms of size, weight, and performance compared with a validated conventional continuous BP monitoring device based on tonometry (conventional device). The performance was evaluated using the correlation coefficient of pulse wave signals and the difference in BbB BP values between the two devices. Measurement data obtained from 30 subjects with a total of 81 sets, including short-term BPV by the Valsalva maneuver, was used for the evaluation of the performance. The results showed that the conventional device consists of two units (a control unit and a sensor unit), while the BbB device has integrated them into a single unit, with a weight of 150 g (approximately 1/45th of the conventional device). The BbB device was significantly smaller and more lightweight than the conventional device. The correlation coefficient of pulse wave signals between the two devices was 0.98 ± 0.02. The BbB systolic BP and diastolic BP differences were -0.3 ± 4.7 mmHg and 0.7 ± 3.4 mmHg, respectively. The developed BbB device was demonstrated to have an almost equivalent performance as the validated conventional device. In conclusion, we realized a small and lightweight continuous BP monitor that can evaluate the BP for each heartbeat using the BbB device without limitations regarding measurement location. Our device can monitor changes in BP at each heartbeat and short-term BPV, which would be important index for preventing CV events.


Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial , Esfigmomanometros , Presión Sanguínea , Frecuencia Cardíaca , Humanos , Manometría
13.
J Hepatobiliary Pancreat Sci ; 28(1): 1-25, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33200538

RESUMEN

BACKGROUND: Hepatectomy is standard treatment for colorectal liver metastases; however, it is unclear whether liver metastases from other primary cancers should be resected or not. The Japanese Society of Hepato-Biliary-Pancreatic Surgery therefore created clinical practice guidelines for the management of metastatic liver tumors. METHODS: Eight primary diseases were selected based on the number of hepatectomies performed for each malignancy per year. Clinical questions were structured in the population, intervention, comparison, and outcomes (PICO) format. Systematic reviews were performed, and the strength of recommendations and the level of quality of evidence for each clinical question were discussed and determined. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach was used to assess evidence and make recommendations. RESULTS: The eight primary sites were grouped into five categories based on suggested indications for hepatectomy and consensus of the guidelines committee. Fourteen clinical questions were devised, covering five topics: (1) diagnosis, (2) operative treatment, (3) ablation therapy, (4) the eight primary diseases, and (5) systemic therapies. The grade of recommendation was strong for one clinical question and weak for the other 13 clinical questions. The quality of the evidence was moderate for two questions, low for 10, and very low for two. A flowchart was made to summarize the outcomes of the guidelines for the indications of hepatectomy and systemic therapy. CONCLUSIONS: These guidelines were developed to provide useful information based on evidence in the published literature for the clinical management of liver metastases, and they could be helpful for conducting future clinical trials to provide higher-quality evidence.


Asunto(s)
Neoplasias Hepáticas , Hepatectomía , Humanos , Neoplasias Hepáticas/cirugía
14.
Glob Health Med ; 2(5): 319-327, 2020 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-33330827

RESUMEN

To clarify the early hemodynamics of hepatocellular carcinoma (HCC), we defined the early portal phase of contrast-enhanced ultrasound (CEUS) and examined the reliability of this modality for determining HCC differentiation. Starting in 2007, we performed Sonazoid CEUS in 146 pathologically confirmed hepatic nodules; 118 HCC (8 poorly [Pd], 73 moderately [Md] and 37 well-differentiated [Wd]) and 28 benign nodules. We focused on the pure arterial and early portal phases up to 45 seconds after Sonazoid injection, and then the subsequent phase up to 30 minutes. We calculated covariance-adjusted sensitivities for nodule enhancement combinations of these three phases. Nodule enhancements were divided into hypo, iso and hyper. A positive predictive value of 100% was obtained for the following patterns: iso-iso-hypo, hypo-iso-iso, and hypo-hypo-hypo for Wd, hyper-iso-hypo and hyper-hypo-hypo for Md, hypo-hyper-hypo for Pd, and hyper-hyper-hyper for benign nodules. In Wd HCC (early HCC), there were seven enhancement patterns, thought to be characterized by various hemodynamic changes from early to advanced HCC. Two patterns allowing a diagnosis of Wd HCC were hypo in the pure arterial phase. Subsequent iso-enhancement in the early portal phase indicated a portal blood supply. Decreased enhancement in the early portal phase allows a diagnosis of Md HCC. However, gradual enhancement observed from the pure arterial to the early portal phase allows a diagnosis of Pd HCC. Therefore, even in the early portal phase, hemodynamic changes were visible not only in Wd but also in Md and Pd HCC. In conclusion, with division of the early phase hemodynamics into pure arterial and early portal phases, CEUS can provide information useful for determining the likely degree of HCC differentiation and for distinguishing early stage HCC from benign nodules.

15.
Med Biol Eng Comput ; 58(6): 1393-1404, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32281072

RESUMEN

Blood pressure (BP) variability is one of the important risk factors of cardiovascular disease (CVD). "Surge BP," which represents short-term BP variability, is defined as pathological exaggerated BP increase capable of triggering cardiovascular events. Surge BP is effectively evaluated by our new BP monitoring device. To the best of our knowledge, we are the first to develop an algorithm for the automatic detection of surge BP from continuous "beat-by-beat" (BbB) BP measurements. It enables clinicians to save significant time identifying surge BP in big data from their patients' continuous BbB BP measurements. A total of 94 subjects (74 males and 20 females) participated in our study to develop the surge BP detection algorithm, resulting in a total of 3272 surges collected from the study subjects. The surge BP detection algorithm is a simple classification model based on supervised learning which formulates shape of surge BP as detection rules. Surge BP identified with our algorithm was evaluated against surge BP manually labeled by experts with 5-fold cross validation. The recall and precision of the algorithm were 0.90 and 0.64, respectively. Processing time on each subject was 11.0 ± 4.7 s. Our algorithm is adequate for use in clinical practice and will be helpful in efforts to better understand this unique aspect of the onset of CVD. Graphical abstract Surge blood pressure (surge BP) which is defined as pathological short-term (several tens of seconds) exaggerated BP increase capable of triggering cardiovascular events. We have already developed a wearable continuous beat-by-beat (bBb) BP monitoring device and observed surge BPs successfully in obstructive sleep apnea patients. In this, we developed an algorithm for the automatic detection of surge BP from continuous BbB BP measurements to save significant time identifying surge BP among > 30,000 BbB BP measurements. Our result shows this algorithm can correctly detect surge BPs with a recall of over 0.9.


Asunto(s)
Algoritmos , Determinación de la Presión Sanguínea/métodos , Hipertensión/diagnóstico , Apnea Obstructiva del Sueño/fisiopatología , Anciano , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea/instrumentación , Determinación de la Presión Sanguínea/normas , Monitoreo Ambulatorio de la Presión Arterial/instrumentación , Monitoreo Ambulatorio de la Presión Arterial/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sueño/fisiología , Apnea Obstructiva del Sueño/diagnóstico
16.
Surg Case Rep ; 6(1): 104, 2020 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-32430849

RESUMEN

BACKGROUND: The Fontan procedure has been widely accepted for children with single ventricle physiology and guarantees survival rates of approximately 80% at age 20 years. However, there have been cases of Fontan-associated liver disease (FALD) caused due to congestion, along with recent reports of the development of hepatocellular carcinoma (HCC) in younger patients with FALD. The literature consists of only five previous case reports of patients who underwent hepatectomy for HCC due to poorer cardiac function and liver cirrhosis caused due to congestion. CASE PRESENTATION: The patient was a 37-year-old woman who presented with epigastralgia. Computed tomography (CT) revealed a liver tumor, 8 cm in diameter, in the caudate lobe. Liver damage was A, with an indocyanine green retention rate of 6% at 15 min. The levels of alpha-fetoprotein (AFP) and protein induced by vitamin K antagonists-II (PIVKA-II) were elevated to 81,663 ng/ml (normal < 10 ng/ml) and 238 mAU/ml (normal < 40 mAU/ml), respectively. Left ventricular ejection fraction was 56%, and central venous pressure (CVP) was 12 mmHg. Left hepatectomy and caudate lobe resection were successfully performed in the reverse Trendelenburg position which reduced the CVP. The total operation duration was 450 min, with a total blood loss of 3200 ml. The patient's postoperative course was uneventful, and she is still alive 16 months after surgery. CONCLUSIONS: First left hepatectomy with caudate lobectomy during reverse Trendelenburg position which reduced the CVP was performed in a patient with HCC and FALD.

17.
Surg Case Rep ; 6(1): 195, 2020 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-32748049

RESUMEN

BACKGROUND: There are no previous reports of debulking of giant liver hemangioma. This report describes our experience with debulking surgery for a patient with bilateral giant liver hemangiomas with severe symptoms. CASE PRESENTATION: We present a case of symptomatic giant liver hemangioma in a 41-year-old woman. She presented with abdominal pain and fullness at a local hospital and underwent trans-arterial embolization (TAE). TAE was not effective, and she was not able to walk a long distance. Giant liver hemangiomas, 30 cm and 15 cm in diameter, were located in the right liver and in the left lateral section, respectively, and normal liver parenchyma with tiny liver hemangiomas was present in segment 4. The liver function was normal. However, right hemi-hepatectomy with left lateral sectionectomy was considered to be risky according to the 3DCT volumetry. Therefore, we performed right hemi-hepatectomy in order to reduce her symptoms. The postoperative course was uneventful, and she was discharged on the 14th day after surgery. The abdominal fullness and abdominal pain disappeared immediately after surgery. The hemangiomas in the remnant liver, 15 cm in diameter, showed no change, and she is well without symptoms 7 years after surgery. CONCLUSIONS: Debulking surgery is one of the options for bilateral giant liver hemangiomas with severe symptoms.

18.
J Hepatobiliary Pancreat Sci ; 27(12): 922-930, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32367664

RESUMEN

BACKGROUND/PURPOSE: Anatomical sectionectomy or larger resection is known to be effective in patients with hepatocellular carcinoma (HCC) with microvascular invasion. A non-smooth tumor margin on hepatobiliary-phase gadoxetic acid disodium-enhanced magnetic resonance imaging (EOB-MRI) can predict microvascular invasion of HCC. We evaluated the usefulness of EOB-MRI for operative planning. METHODS: We evaluated 224 patients with single HCC who underwent hepatectomy between 2010 and 2013. The tumor margin was determined preoperatively. The hepatic resection was determined based on tumor location, liver function, 3D CT simulation and functional liver reserve. To control for confounding variable distributions, propensity score match was applied to compare the outcomes. Multivariate analysis was conducted to identify independent predictors of 5-year recurrence-free survival (RFS) and overall survival (OS). RESULTS: Of 113 patients with a non-smooth tumor margin, 40 patients (35%) showed microscopic portal invasion. The 5-year RFS and OS rates were significantly higher after sectionectomy or larger hepatectomy (hemihepatectomy) than after segmentectomy or smaller hepatectomy (non-anatomical resection). Of 111 patients with a smooth tumor margin, eight patients (7%) showed microscopic portal invasion. The 5-year RFS and OS rates did not differ significantly between patients who underwent sectionectomy and those who underwent segmentectomy. CONCLUSIONS: Our preliminary results appear to recommend that HCC with a non-smooth margin on HB-phase images is treated with anatomical sectionectomy or larger hepatectomy.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/cirugía , Medios de Contraste , Gadolinio DTPA , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Imagen por Resonancia Magnética , Recurrencia Local de Neoplasia/diagnóstico por imagen , Estudios Retrospectivos
19.
Surg Case Rep ; 6(1): 171, 2020 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-32661725

RESUMEN

BACKGROUND: Ring calcification in hepatocellular carcinoma is extremely rare. Untreated hepatocellular carcinoma occasionally includes calcified lesions. Here, we report a case of ring-calcified hepatocellular carcinoma. CASE PRESENTATION: A 60-year-old man with a hepatic tumor was referred to Tokyo Women's Medical University Hospital. He had a history of chronic hepatitis C. Computed tomography showed a liver tumor 20 mm in diameter in segment 6 of the Couinaud classification, with ring calcification. Based on this uncommon imaging presentation and the patient's past exposure to the definitive hosts of Echinococcus multilocularis, he was preoperatively diagnosed with echinococcosis. Partial hepatectomy was performed as a radical treatment for echinococcosis. A final diagnosis of hepatocellular carcinoma was confirmed based on pathological findings. The patient was discharged uneventfully. CONCLUSION: The presentation of an extremely rare hepatocellular carcinoma with ring calcification may be disguised as hydatid disease.

20.
Mol Clin Oncol ; 12(3): 290-294, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32064109

RESUMEN

Although vascular invasion is an important factor in the progression and treatment of hepatocellular carcinoma (HCC), it remains difficult to determine, on the basis of preoperative imaging alone, whether vascular invasion, especially microvascular invasion, has occurred. The current retrospective study enrolled 292 patients who, between 2004 and 2014, underwent curative hepatectomy as an initial treatment for HCC. The patients were divided between those with (n=70) and those without (n=222) microvascular invasion. Whether tumor-marker-based prediction of microvascular invasion was possible was assessed by comparing the preoperative serum α-fetoprotein (AFP) and prothrombin induced by vitamin K absence or antagonist-II concentrations between two groups of patients. The AFP concentration was significantly higher in patients with microvascular invasion compared with patients without microvascular invasion (P=0.0019). Stepwise logistic regression analysis demonstrated the AFP concentration and the logarithmic conversion ratio of the AFP gradient (log AFP grad) to be useful (P=0.0019; 0.0424) for predicting microvascular invasion. The serum AFP concentration and log AFP grad appear to be clinically useful in predicting microvascular invasion in patients with HCC.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA