Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
BMC Pediatr ; 19(1): 464, 2019 11 27.
Artículo en Inglés | MEDLINE | ID: mdl-31775688

RESUMEN

BACKGROUND: This study aims to provide guidance for clinical work through analysis of the clinical characteristics, endoscopic and pathological manifestations, diagnosis, and treatment of an 18-day-old neonate with exfoliative esophagitis. CASE PRESENTATION: The patient presented with vomiting but the parents did not pay too much attention. The pathological report revealed numerous fibrinous exudative necrotic, and inflammatory cells, as well as a small amount of squamous epithelium. Furthermore, milk allergy factors were considered. Conservative treatments, such as fasting, acid suppression, mucosal protection, parenteral nutrition, and the replacement of anti-allergic milk powder were given. Thereafter, endoscopic examination revealed that the patient returned to normal, and was discharged after 21 days. CONCLUSIONS: Exfoliative esophagitis has multiple causes; and has characteristic clinical and endoscopic manifestations. Endoscopic examination after 18 days presentation and conservative therapy revealed that the esophagus had returned to a normal appearance and the patient was discharged. Following discharge, the parents were advised to feed the patient ALFERE powder. Attention should be given to the timely detection of complications and corresponding treatment.


Asunto(s)
Mucosa Esofágica/patología , Esofagitis/patología , Proteína C-Reactiva/análisis , Epitelio/patología , Esofagitis/sangre , Esofagitis/complicaciones , Esofagoscopía , Humanos , Recién Nacido , Labio/patología , Enfermedades de los Labios/complicaciones , Enfermedades de los Labios/patología , Masculino , Vómitos/etiología
2.
Int J Gen Med ; 14: 4529-4534, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34421311

RESUMEN

BACKGROUND: Neonatal ventilator-associated pneumonia (NVAP) is one of the main infections acquired in hospitals, and soluble triggering receptors expressed on myeloid cells-1 (sTREM-1) are a TREM-1 subtype that can be released into the blood or bodily fluids during an infection. METHODS: The patients included in the present study were divided into three groups: the NVAP group, the first control group, and the second control group (n = 20, each). Children requiring respiratory treatment were assigned to the NVAP group, newborns who received mechanical ventilation and had neonatal respiratory distress syndrome were assigned to the first control group, and newborns with normal X-ray and electrocardiogram results but no non-pulmonary infection was assigned to the second control group. The blood and bronchoalveolar lavage fluid (BALF) sTREM-1 levels in all newborns were analyzed. RESULTS: The acute-phase blood and BALF sTREM-1 levels were significantly higher in the NVAP group than in the first control group, and the blood sTREM-1 expression level was lower in the second control group than in the NVAP group. CONCLUSION: The present results suggest that sTREM-1 might be a useful biomarker for NVAP prediction in the Department of Pediatrics.

3.
Zhonghua Er Ke Za Zhi ; 45(6): 446-9, 2007 Jun.
Artículo en Zh | MEDLINE | ID: mdl-17880793

RESUMEN

OBJECTIVE: To evaluate the usefulness of a broad-range real-time PCR assay aimed at the 16S rRNA gene of bacteria in a clinical setting in rapid and reliable diagnosis of neonatal septicemia for improving the speed and accuracy of bacterial detection. METHODS: The universal primer and TaqMan probe were designed based on the highly conserved sequences of the bacterial 16S rRNA gene. The chosen primers and probe did not show any likely cross hybridization with human, viral or fungal genome sequences. The TaqMan assay used the fluorescent signal on the probe, such as 6-carboxyfluorescin (6-FAM), and quenched by the standard 6-carboxytetramethylrhodamine (TAMRA) probes. The broad-range 16S rRNA gene real-time PCR array was established. Then, three common pathogenic microorganisms including Staphylococcus aureus, Staphylococcus epidermidis and Escherichia coli, which were prepared by a 10-fold dilution series respectively from 10(8) colony forming unit (CFU)/ml to 10(3) CFU/ml, as well as controls, were used for testing of both sensitivity and specificity of the real-time PCR assay. The blood samples from 830 cases of suspected septicemia, who were hospitalized in our neonatal ward and the neonatal intensive care unit (NICU) and developed clinical signs suggestive of infection, were tested with routine culture and bacterial 16S rRNA genes real-time PCR separately. In addition, 30 neonates without infection were enrolled as the negative control group. RESULTS: All the three common pathogenic bacterial species were positive on the 16S rRNA genes real-time PCR assay. There were no cross-reaction with cytomegalovirus (CMV), Epstein-Barr virus (EBV), hepatitis B virus (HBV), fungi, human DNA and blank control, and the technique showed high specificity and sensitivity. The detection limit of the TaqMan assay was tested by amplifying serial dilutions of the three common pathogenic bacterial DNA. The minimal detection limit of the TaqMan system was equivalent to 3 CFU of bacteria, the threshold cycle (CT), which is inversely proportional to the log of the amount of target DNA initially present, was 37.90 by calculation. The real-time PCR assay was evaluated on 830 blood specimens for suspected neonatal septicemia, as compared to the results obtained from the routine bacterial cultures. The positive rate by the real-time PCR assay was 5.18% (43/830) in 830 samples, and was significantly higher than that of blood culture [2.41% (20/830) (P < 0.01)]. The real-time PCR was positive in all the 20 positive blood culture samples. Thirty non-infectious blood samples were negative by both the PCR assay and blood cultures. When blood culture was used as control, the sensitivity of the real-time PCR assay was 100%, the specificity was 97.16%, and the index of accurate diagnosis was 0.972. Moreover, three of the PCR positive amplicons were confirmed by sequencing to confirm the accuracy of the real-time PCR assay in testing clinical specimens. The sequencing showed that except for one sequence, all the others were demonstrated to be Staphylococcus aureus and Escherichia coli respectively, which was in accord with the results of the blood cultures. CONCLUSIONS: The bacterial 16S rRNA genes real-time PCR had been established to diagnose the neonatal septicemia. The sensitivity and specificity the real-time PCR assay were higher than those of blood culture. This technique can provide a rapid way for the etiological diagnosis of neonatal septicemia, and was a convenient and accurate method in etiologic diagnosis of neonatal septicemia.


Asunto(s)
ADN/análisis , ARN Ribosómico 16S/análisis , Sepsis/diagnóstico , Cartilla de ADN , Escherichia coli/genética , Genes de ARNr/genética , Herpesvirus Humano 4/genética , Herpesvirus Humano 4/aislamiento & purificación , Humanos , Recién Nacido , Límite de Detección , Hibridación de Ácido Nucleico , Reacción en Cadena de la Polimerasa/métodos , Rodaminas , Sensibilidad y Especificidad , Sepsis/genética , Análisis de Secuencia de ADN , Staphylococcus aureus/genética , Staphylococcus epidermidis/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA