Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 34(6): 1395-1404, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37232426

RESUMEN

AIM: Ventricular arrhythmias (VAs) are the most common cause of death in patients with repaired Tetralogy of Fallot (rTOF). However, risk stratifying remains challenging. We examined outcomes following programmed ventricular stimulation (PVS) with or without subsequent ablation in patients with rTOF planned for pulmonary valve replacement (PVR). METHODS: We included all consecutive patients with rTOF referred to our institution from 2010 to 2018 aged ≥18 years for PVR. Right ventricular (RV) voltage maps were acquired and PVS was performed from two different sites at baseline, and if non-inducible under isoproterenol. Catheter and/or surgical ablation was performed when patients were inducible or when slow conduction was present in anatomical isthmuses (AIs). Postablation PVS was undertaken to guide implantable cardioverter-defibrillator (ICD) implantation. RESULTS: Seventy-seven patients (36.2 ± 14.3 years old, 71% male) were included. Eighteen were inducible. In 28 patients (17 inducible, 11 non-inducible but with slow conduction) ablation was performed. Five had catheter ablation, surgical cryoablation in 9, both techniques in 14. ICDs were implanted in five patients. During a follow-up of 74 ± 40 months, no sudden cardiac death occurred. Three patients experienced sustained VAs, all were inducible during the initial EP study. Two of them had an ICD (low ejection fraction for one and important risk factor for arrhythmia for the second). No VAs were reported in the non-inducible group (p < .001). CONCLUSION: Preoperative EPS can help identifying patients with rTOF at risk for VAs, providing an opportunity for targeted ablation and may improve decision-making regarding ICD implantation.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Válvula Pulmonar , Taquicardia Ventricular , Tetralogía de Fallot , Humanos , Masculino , Adolescente , Adulto , Adulto Joven , Persona de Mediana Edad , Femenino , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Tetralogía de Fallot/complicaciones , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Resultado del Tratamiento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía
2.
Circ J ; 87(12): 1711-1719, 2023 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-37258224

RESUMEN

BACKGROUND: Pulmonary vein stenosis (PVS) after PV isolation (PVI) for atrial fibrillation (AF) is a severe complication that requires angioplasty. This study aimed to compare the reduction of the cross-sectional PV area (PVA) and the incidence of PVS after cryoballoon (CB)-PVI, hot balloon (HB)-PVI, or laser balloon (LB)-PVI.Methods and Results: A total of 320 patients who underwent an initial catheter ablation procedure for AF using a CB, HB, or LB in 2 hospitals were included. They underwent contrast-enhanced multidetector CT before and 3 months after the procedure. In all 4 PVs, the reduction in PVA was more significant in the LB group than in the CB or HB groups, respectively. Moderate (50-75%) and severe (>75%) PVS were observed in 5.3% and 0.5% of the PVs, respectively. Although moderate PVS was more frequently observed in the LB group than in the CB or HB groups (8.2%, 3.8%, and 5.0%; P=0.03), the incidence of severe PVS was similar in the LB, CB, and HB groups (0.3%, 0.5%, and 1.0%; P=0.46). Symptomatic PVS requiring intervention occurred in 1 (0.3%) patient. CONCLUSIONS: Although the reduction in cross-sectional PVA and the incidence of moderate PVS after LB-PVI was more significant than after CB-PVI or HB-PVI, it rarely led to severe PVS. Symptomatic PVS requiring intervention was rare after the balloon ablation of AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Estenosis de Vena Pulmonar , Humanos , Estenosis de Vena Pulmonar/diagnóstico por imagen , Estenosis de Vena Pulmonar/etiología , Estudios Transversales , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Criocirugía/efectos adversos , Criocirugía/métodos , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Rayos Láser
3.
Heart Vessels ; 38(3): 413-421, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36194289

RESUMEN

The "pre-freezing" technique was a method in which a fully inflated balloon after the start of freezing was pressed against the pulmonary vein (PV) during cryoballoon ablation and has been applied especially in large-size PVs. Of 556 patients who underwent cryoballoon ablation for atrial fibrillation (AF), the pre-freezing technique was applied to 48 patients. The resulting 2:1 propensity score-matched data set included 120 patients. Using the pre-freezing technique, all left-superior PVs, all left-inferior PVs, and 95% of right-superior PVs were successfully isolated. In most right-inferior PVs, complete sealing using the pre-freezing technique was challenging, and this technique was not applied. Procedure time was similar between the two groups. In the pre-freezing group, the percentage of the left atrial posterior wall isolated was larger (47.6 ± 10.3 vs. 42.8 ± 15.7%, P = 0.006), and the postoperative reduction of diaphragmatic compound motor action potentials tended to occur less frequently (2.5 vs. 12.5%, P = 0.07), and the reduction of the cross-sectional LSPV area was smaller (17.5 ± 12.2 vs. 27.2 ± 19.8%, P = 0.03) than the conventional group. The AF-free rate of the two groups was similar between the two groups (P = 0.15). The pre-freezing technique was a simple method that can isolate a wider surface area during cryoballoon PV isolation. While the postoperative AF recurrence was comparable, the postoperative reduction in the cross-sectional PV area was less than that of the conventional method, which may reduce the risk of PV stenosis.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Congelación , Estudios Transversales , Criocirugía/efectos adversos , Criocirugía/métodos , Resultado del Tratamiento
4.
Curr Cardiol Rep ; 25(6): 535-542, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37115434

RESUMEN

PURPOSE OF REVIEW: Imaging plays a crucial role in the therapy of ventricular tachycardia (VT). We offer an overview of the different methods and provide information on their use in a clinical setting. RECENT FINDINGS: The use of imaging in VT has progressed recently. Intracardiac echography facilitates catheter navigation and the targeting of moving intracardiac structures. Integration of pre-procedural CT or MRI allows for targeting the VT substrate, with major expected impact on VT ablation efficacy and efficiency. Advances in computational modeling may further enhance the performance of imaging, giving access to pre-operative simulation of VT. These advances in non-invasive diagnosis are increasingly being coupled with non-invasive approaches for therapy delivery. This review highlights the latest research on the use of imaging in VT procedures. Image-based strategies are progressively shifting from using images as an adjunct tool to electrophysiological techniques, to an integration of imaging as a central element of the treatment strategy.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Arritmias Cardíacas , Corazón , Frecuencia Cardíaca , Ablación por Catéter/métodos , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 33(9): 2100-2103, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35842800

RESUMEN

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) in patients with tachycardia-bradycardia syndrome (TBS) can be a major therapeutic option to replace permanent pacemaker implantation (PMI). However, the very long-term outcome of more than 15 years in these patients has not been elucidated. METHODS: From 2002 to 2008, 25 consecutive TBS patients (62 ± 7.9 years old, 68% male) with both AF and symptomatic sinus pauses (>3.0 s) were performed radiofrequency AF ablation. These patients were followed for 15 ± 2.7 years. RESULTS: The median longest sinus pause before the ablation procedure was 6.0 s (4.4-8.0). Following 1.6± 0.8 ablation procedures, 18 (72%) patients remained free from AF. Three (12%) patients died due to noncardiovascular causes, and seven (28%) patients underwent PMI due to symptomatic sinus pause after recurrent AF in five patients and progression of sinus node dysfunction in two patients. The median duration from the first AF ablation to PMI was 6.3 years (range: 9 days to 11.0 years). Five and two patients required PMI more than 5 and 10 years after the first ablation procedure, respectively. CONCLUSION: AF ablation prevented PMI in 72% of TBS patients for a 15-year follow-up. However, in consideration of the long duration of PMI, a continuous careful long-term follow-up was warranted.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Bradicardia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Síndrome del Seno Enfermo/terapia , Taquicardia/diagnóstico , Taquicardia/cirugía , Resultado del Tratamiento
6.
Circ J ; 86(8): 1229-1236, 2022 07 25.
Artículo en Inglés | MEDLINE | ID: mdl-35786690

RESUMEN

BACKGROUND: Pulmonary vein (PV) stenosis after atrial fibrillation (AF) ablation is rare; however, it remains a serious complication. PV angioplasty is reportedly an effective therapy; however, a dedicated device for PV angioplasty has not been developed, and the detailed procedural methods remain undetermined. This study describes the symptoms, indications, treatment strategies, and long-term outcomes for PV stenosis after AF ablation.Methods and Results: This study retrospectively analyzed 7 patients with PV stenosis after catheter ablation for AF and who had undergone PV angioplasty at our hospital during 2015-2021. PV stenosis occurred in the left superior (5 patients) and left inferior (2 patients) PV. Six patients had hemoptysis, chest pain, and dyspnea. Seven de novo lesions were treated using balloon angioplasty (BA) (3 patients), a bare metal stent (BMS) (3 patients), and a drug-coated balloon (DCB) (1 patient). The restenosis rate was 42.9% (n=3; 2 patients in the BA group and 1 patient in the DCB group). The repeat treatment rate was 28.6% (2 patients in the BA group). Stenting was performed as repeat treatment. One patient with subsequent repeat restenosis development underwent BA. Ten PV angioplasties were performed; there were no major complications. CONCLUSIONS: Regarding PV angioplasty after ablation therapy for AF, stenting showed superior long-term PV patency than BA alone; therefore, it should be considered as a standard first-line approach.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Estenosis de Vena Pulmonar , Angioplastia/efectos adversos , Angioplastia/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Constricción Patológica/complicaciones , Humanos , Venas Pulmonares/cirugía , Estudios Retrospectivos , Estenosis de Vena Pulmonar/diagnóstico por imagen , Estenosis de Vena Pulmonar/etiología , Estenosis de Vena Pulmonar/terapia , Resultado del Tratamiento
7.
Heart Vessels ; 37(1): 110-114, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34216250

RESUMEN

The temporal changes in ambulatory monitoring findings after cryoballoon (CB) ablation of atrial fibrillation (AF) have not been well elucidated. This study aims to compare the details of ambulatory monitoring after CB and radiofrequency catheter (RFC) ablation for AF. Of 724 consecutive AF patients who underwent initial ablation using a CB or RFC, 508 (254 pairs) were selected using propensity score matching. Ambulatory monitoring was performed at 1, 3, 6, 12, 24 and 36 months after the procedure. After 1, 3 and 6 months, the number of total heart beats (THBs) was larger in the CB group than in the RFC group. It gradually decreased and became significantly similar by 12 months after ablation. THBs significantly increased 1, 3, 6 and 12 months after ablation in both the RFC and CB groups and became statistically similar by 24 months after ablation. The atrial premature contraction burden was higher in the RFC group than in the CB group at 3 months after ablation. THB and APC burden after AF ablation were significantly different between the RF and CB groups. THBs returned to statistically similarity by 2 years after ablation in both groups.


Asunto(s)
Fibrilación Atrial , Complejos Atriales Prematuros , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Complejos Atriales Prematuros/diagnóstico , Criocirugía/efectos adversos , Frecuencia Cardíaca , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
8.
Heart Vessels ; 36(9): 1430-1437, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33721036

RESUMEN

Although antiarrhythmic drugs have long been used for the suppression of various types of arrhythmias, their prior use before the onset of ventricular arrhythmia with hemodynamic collapse and the effect on prognosis is not well known. Data from 1004 consecutive patients with cardiovascular shock in the Japanese Circulation Society's Shock Registry were analyzed. Eighty-four cases of ventricular arrhythmia-induced shock and ROSC (return of spontaneous circulation) were divided into the prior amiodarone or ß-blockers use group (Aß group, n = 27) and the non-amiodarone and non-ß-blockers use group (non-Aß group; n = 57) based on treatment before the onset of those arrhythmias. Clinical outcomes related to hemodynamic collapse such as OHCA (out-of-hospital cardiovascular arrest) was less in the Aß group [Aß group, 11/26 (42%) vs. non-Aß group, 41/56 (73%); p = 0.007]. Similarly, syncope was less common in the Aß group than in the non-Aß group [Aß group 4/27 (15%) vs. non-Aß group 27/57 (47%); p = 0.004]. Furthermore, prior amiodarone or ß-blockers use before the onset of ventricular arrhythmias was strongly associated with both survival at discharge (odds ratio 3.19; 95% confidence interval 1.06-9.67; p = 0.040) and neurological outcomes at discharge (odds ratio 3.96; 95% confidence interval 1.32-11.85; p = 0.014) based on multivariate logistic regression analysis. Prior amiodarone or ß-blockers use before the onset of malignant ventricular arrhythmia and maintaining appropriate blood concentrations in advance is associated with a good survival rate and better neurological outcomes after recovery from ventricular arrhythmia with hemodynamic collapse.


Asunto(s)
Amiodarona/uso terapéutico , Fibrilación Ventricular , Antagonistas Adrenérgicos beta/uso terapéutico , Antiarrítmicos/uso terapéutico , Arritmias Cardíacas , Hemodinámica , Humanos , Pronóstico , Fibrilación Ventricular/tratamiento farmacológico
9.
J Cardiovasc Electrophysiol ; 31(8): 2222-2225, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32608049

RESUMEN

We present a case of a 67-year-old female with a previous history of pulmonary vein isolation for paroxysmal atrial fibrillation who presented with supraventricular bigeminy with a constant coupling interval. The supraventricular bigeminy originated from the anterior mitral annulus with initial mapping suggestive of a focal mechanism. However detailed mapping using an ultrahigh resolution mapping system (with the manual shifting of the annotation window) revealed very low amplitude potentials connecting the previous sinus beat with continuous activation along the mitral annulus. Our observations were indicative of a re-entry mechanism underlying the supraventricular bigeminy.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Femenino , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Venas Pulmonares/cirugía
10.
World J Surg ; 44(10): 3441-3448, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32474625

RESUMEN

BACKGROUND: Mesopancreas excision in pancreatoduodenectomy is technically complicated because of the anatomical complexity of the mesopancreas with the inferior peripancreatic blood vessels which is caused by intestinal rotation in fetal life. We have developed a novel artery-first approach (the intestinal derotation procedure) for facilitating mesopancreas excision. The aim of this study was to clarify the vascular anatomy of the mesopancreas after derotation. METHODS: The right-sided colon and small intestine are mobilized from the retroperitoneum, and the intestinal loop is then derotated. In 136 cases of pancreatoduodenectomy employing the derotation procedure, we analyzed the vascular anatomy of the mesopancreas. RESULTS: After derotation, the anatomy was simplified. The mesopancreas extended from the right aspect of the superior mesenteric artery (SMA), forming a horizontal plane. The first jejunal trunk (FJT) was situated in parallel with the second jejunal artery and was anterior (91%) or posterior (9%) to the SMA. The inferior pancreaticoduodenal vein (IPDV) entered the right side of the FJT (83%) or the superior mesenteric vein (17%). Besides the IPDV, 1-4 tributaries entered the right wall of the FJT, in 89% of cases. The inferior pancreaticoduodenal artery was observed to originate from the right wall of the SMA, sharing a common stem with the first jejunal artery (70%) or branching directly from the SMA (29%). CONCLUSIONS: Intestinal derotation simplifies the mesopancreas anatomy and reveals the anatomical details of the inferior peripancreatic blood vessels in pancreatoduodenectomy.


Asunto(s)
Intestinos/cirugía , Páncreas/irrigación sanguínea , Pancreaticoduodenectomía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Arteria Mesentérica Superior/cirugía , Persona de Mediana Edad , Rotación
11.
Heart Vessels ; 35(10): 1378-1389, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32399662

RESUMEN

The effects of empagliflozin, a sodium-glucose co-transporter 2 inhibitor, on neointimal response after drug-eluting-stent (DES) implantation remains unknown. Insufficiently controlled diabetes patients with coronary artery disease planned for DES stenting were consecutively enrolled. The patients were assigned to receive empagliflozin in addition to standard therapy or intensive therapy using other glucose-lowering drugs (oGLD). The primary endpoint was thickness of neointimal hyperplasia (NIH) 12 months after stenting assessed by optical coherence tomography (OCT). A total of 28 patients were analyzed (n = 15 in the empagliflozin group, n = 13 in the oGLD group). The levels of glucose profile were not significantly different between both groups at follow-up [HbA1c; 7.2 ± 0.8 vs 7.3 ± 0.9%, p = 0.46]. In OCT analysis, neointima was significantly less in the empagliflozin group than the oGLD group [mean NIH thickness: 137 ± 32 vs 168 ± 39 µm, p = 0.02]. Changes of systolic and diastolic blood pressure (BP), changes of body mass index, and changes of hematocrit after additional treatment were significantly associated with NIH attenuation, whereas no correlation was observed in changes in blood glucose parameters. Multivariate logistic regression analysis revealed that changes in systolic BP was the strongest predictor for NIH attenuation, followed by changes in diastolic BP. In patients with type 2 diabetes, standard plus empagliflozin attenuated neointimal progression as compared with intensive standard therapy after DES implantation. Our data possibly support a beneficial effect of empagliflozin in type 2 diabetes required for coronary revascularization therapy.


Asunto(s)
Compuestos de Bencidrilo/uso terapéutico , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/efectos de los fármacos , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Stents Liberadores de Fármacos , Glucósidos/uso terapéutico , Neointima , Intervención Coronaria Percutánea/instrumentación , Inhibidores del Cotransportador de Sodio-Glucosa 2/uso terapéutico , Anciano , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/diagnóstico , Femenino , Humanos , Hiperplasia , Japón , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Factores de Tiempo , Tomografía de Coherencia Óptica , Resultado del Tratamiento
12.
J Cardiovasc Electrophysiol ; 30(11): 2310-2318, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31452290

RESUMEN

BACKGROUND: The presence of heart failure (HF) has been associated with poorer outcomes in patients undergoing catheter ablation (CA) for atrial fibrillation (AF). However, the effectiveness of CA amongst the subset of patients with tachycardia-induced cardiomyopathy (TIC) remains poorly defined. METHODS AND RESULTS: In a retrospective analysis we compared outcomes of first-time CA for persistent AF in a cohort of patients with previously diagnosed TIC (n = 45; age 58 ± 8 years; 91% male) to those with structurally normal hearts (non-TIC; n = 440; age 55 ± 9 years; 95% male). TIC was defined as an impaired ventricular function (left ventricular ejection function [LVEF] <50%), which was reversed after the treatment of HF. We compared atrial arrhythmias (AAs) recurrence after the CA in the TIC and non-TIC cohorts. In the TIC group, LVEF improved from 35.8% ± 8.1% to 57.5% ± 8.3% after treatment of HF. During 3.3 ± 1.5 years follow-up, AAs-free survival after CA was significantly higher in the TIC group as compared with the non-TIC group (69% vs 42%; P = .001), despite a comparable CA strategy between the two groups. In multivariable analysis, absence of HF with TIC, longer AF duration, and complex fractionated atrial electrogram ablation were independent predictors of arrhythmia recurrence (OR, 1.02; 95% CI, 1.01-1.03; P < .01; OR, 0.40; 95% CI, 0.20-0.79; P < .01 and OR, 2.29; 95%CI; 1.27-4.11; P < .01, respectively). In addition, the outcome after the last procedure was superior in the TIC cohort (89% vs 72%; P = .03) with fewer CA procedures as compared with the non-TIC cohort (1.3 ± 0.5 vs 1.5 ± 0.7; P = .01). CONCLUSIONS: Persistent patients with AF with TIC have a more favorable outcome after the CA as compared with those without.


Asunto(s)
Fibrilación Atrial/cirugía , Cardiomiopatías/etiología , Ablación por Catéter , Potenciales de Acción , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recuperación de la Función , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
13.
World J Surg ; 40(12): 3021-3028, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27501710

RESUMEN

BACKGROUND: Duct-to-mucosa pancreatojejunostomy after pancreatoduodenectomy can be technically difficult, particularly in cases with a non-dilated pancreatic duct. We devised a novel procedure employing a pancreatic duct holder and mucosa squeeze-out technique facilitating duct-to-mucosa anastomosis. We compared the perioperative outcomes of pancreatoduodenectomy with duct-to-mucosa pancreatojejunostomy between the novel and conventional procedures. METHODS: Our pancreatic holder has a cone-shaped tip with a slit. The holder can expand the pancreatic duct and provides a good surgical field for anastomosis. A small incision for anastomosis is made on the jejunum, while the jejunum is grasped around the incision. Then, the jejunal mucosa becomes squeezed-out and everted. This mucosa squeeze-out technique facilitates suturing the full thickness of the jejunum. Propensity score matching yielded 113 cases each undergoing the novel and the conventional procedure, among 308 cases receiving pancreatoduodenectomy with duct-to-mucosa pancreatojejunostomy. RESULTS: The overall morbidity rate was significantly lower in the novel procedure group. The pancreatic fistula (ISGPF grade B/C) rate was significantly lower in the novel (5 %) than in the conventional (13 %) procedure group. For cases with a non-dilated pancreatic duct (≤3 mm), the rate was significantly lower in the novel (10 %) than in the conventional procedure group (24 %). Multivariate analysis identified a non-dilated pancreatic duct, soft pancreas, and the conventional procedure as factors independently predicting the complication of pancreatic fistula formation. CONCLUSIONS: Our novel procedure facilitates duct-to-mucosa pancreatojejunostomy and decreases the pancreatic fistula rate. This procedure is simple, rational, and useful for achieving anastomosis, particularly in cases with a non-dilated pancreatic duct.


Asunto(s)
Mucosa Intestinal/cirugía , Conductos Pancreáticos/cirugía , Fístula Pancreática/etiología , Pancreatoyeyunostomía/métodos , Anciano , Anastomosis Quirúrgica/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pancreaticoduodenectomía , Pancreatoyeyunostomía/efectos adversos , Pancreatoyeyunostomía/instrumentación , Puntaje de Propensión , Factores de Riesgo
14.
J Arrhythm ; 40(3): 520-526, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38939774

RESUMEN

Background: Hyperuricemia (HU) has been reported to be associated with a high incidence of atrial fibrillation (AF). However, the relationship between HUA and recurrent AF after catheter ablation (CA) is unclear. Methods: Four hundred consecutive AF patients (paroxysmal/persistent AF [PAF/PsAF]: 200/200) who underwent the initial CA were retrospectively enrolled. HU was defined as serum uric acid (SUA) level >7.0 mg/dL. We measured SUA levels 1 day before (pre-CA) and 1 month after CA (post-CA). A second-generation 28 mm cryoballoon was used for pulmonary vein isolation (PVI) for PAF, while PVI plus linear ablation (roof and mitral isthmus lines) by radiofrequency catheter was conducted for PsAF. Results: During 57 ± 24 months of follow-up, AF recurred in 16% and 42% in PAF and PsAF patients (p < .0001). Pre-CA SUA level in PsAF was significantly higher than that in PAF (6.5 ± 1.3 vs. 5.8 ± 1.3 mg/dL, p < .001). SUA level was significantly decreased after CA in both PAF and PsAF (5.8 ± 1.3 vs. 5.6 ± 1.3 mg/dL; p < .01 and 6.5 ± 1.3 vs. 6.1 ± 1.2 mg/dL; p < .0001, respectively). The association between pre-/post-CA HU and recurrent AF was not identified in PAF, while the incidence of post-CA HU was significantly higher in patients with recurrent AF than those without in PsAF (36% vs. 15%, p < .001). In multivariable analysis, longer AF duration and the presence of post-CA HU were identified as independent predictors of AF recurrence in PsAF (OR:1.01, 95%CI:1.003-1.011, p = .0001 and OR:2.77, 95%CI:1.333-5.755, p = .007, respectively). Conclusions: SUA level was significantly higher in PsAF than PAF patients. The presence of post-CA HU was strongly related to AF recurrence in PsAF patients.

15.
J Arrhythm ; 40(4): 830-838, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39139884

RESUMEN

Background: Currently, two types of cryoballoon (CB) systems are available for catheter ablation of atrial fibrillation (AF). Since the POLARx (Boston Scientific) is softer during freezing than the Arctic Front Advance Pro (AFA-Pro; Medtronic), it tends to go more deeply into the pulmonary vein (PV), risking PV stenosis. Methods: Ninety-one patients underwent initial CB ablation for paroxysmal AF (AFA-Pro 56; POLARx 35). Twenty-six from each group were extracted using propensity score matching. The PV cross-sectional area (PVA) was measured by tracing the area within the PV plane at 5-mm intervals from the PV ostium in a distal direction for 20 mm or to the bifurcation in each PV. The PVA was compared before and 3 months after ablation. Results: Time to balloon temperatures of -30 and - 40°C was significantly shorter and the nadir temperature was significantly lower with POLARx than with AFA-Pro. In the left inferior (LI) PV and right superior (RS) PV, the freezing balloon position was significantly deeper in POLARx than in AFA-pro. The freezing position in RSPV with mild to moderate narrowing was deeper than those without (10.2 ± 3.3 mm vs. 8.2 ± 1.8 mm, p = .01). In RSPV, the reduction of PVA tended to be greater with the POLARx than with the AFA-Pro (26.1% ± 14.1% vs. 19.9% ± 10.3%, p = .07). Conclusion: There was no significant difference in the incidence of PV stenosis between POLARx and AFA-Pro. However, if POLARx goes deep into the PVs, we will still have to be careful.

16.
Heart Rhythm ; 21(6): 828-835, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38286245

RESUMEN

BACKGROUND: Differentiating between atypical atrioventricular nodal reentrant tachycardia (AVNRT) and orthodromic reciprocating tachycardia utilizing a septal accessory pathway is a complex challenge. OBJECTIVE: The purpose of this study was to describe the "local VA index," a straightforward method based on signals from the coronary sinus catheter, to distinguish between these arrhythmias during tachycardia and entrainment. The ventriculoatrial (VA) interval on the coronary sinus catheter is measured during tachycardia and entrainment, at the site of earliest atrial activity. The difference between these 2 situations defines the "local VA index." We also propose a mechanism to clarify the limitations of historical pacing maneuvers, such as postpacing interval minus tachycardia cycle length (PPI-TCL) and stimulus-atrial interval minus ventriculoatrial interval (SA-VA), by examining nodal decrement and intraventricular conduction delay. METHODS: In a retrospective study of 75 patients referred for supraventricular tachycardia evaluation, 37 were diagnosed with atrioventricular reentrant tachycardia (AVRT) with orthodromic reciprocating tachycardia, and 38 with AVNRT (27 typical, 11 atypical). RESULTS: In comparison to AVRT patients, AVNRT patients exhibited longer PPI-TCL (176 ± 47 ms vs 113 ± 42 ms; P <.01) and SA-VA (138 ± 47 ms vs 64 ± 28 ms; P <.01). The AVRT group had mean local VA index of -1 ± 13 ms, whereas the AVNRT group had a significantly longer index of 91 ± 46 ms (P <.01). An optimal threshold for differentiation was a local VA index of 40 ms. Importantly, there was no significant correlation between pacing cycle length and nodal decrement as well as intraventricular delay related to pathway location. This interindividual variability might explain misleading interpretations of PPI-TCL and SA-VA. CONCLUSION: This novel approach is advantageous because of its simplicity and effectiveness, requiring only 2 diagnostic catheters. A local VA interval difference <40 ms provides a clear distinction for AVRT.


Asunto(s)
Taquicardia por Reentrada en el Nodo Atrioventricular , Taquicardia Supraventricular , Humanos , Diagnóstico Diferencial , Femenino , Masculino , Estudios Retrospectivos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Persona de Mediana Edad , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología , Electrocardiografía/métodos , Adulto , Sistema de Conducción Cardíaco/fisiopatología , Técnicas Electrofisiológicas Cardíacas/métodos , Taquicardia Reciprocante/diagnóstico , Taquicardia Reciprocante/fisiopatología
17.
Cell Rep ; 42(1): 111944, 2023 01 31.
Artículo en Inglés | MEDLINE | ID: mdl-36640349

RESUMEN

Genome instability can drive aging in many organisms. The ribosomal RNA gene (rDNA) cluster is one of the most unstable regions in the genome and the stability of this region impacts replicative lifespan in budding yeast. To understand the underlying mechanism, we search for yeast mutants with stabler rDNA and longer lifespans than wild-type cells. We show that absence of a transcription elongation factor, Spt4, results in increased rDNA stability, reduced levels of non-coding RNA transcripts from the regulatory E-pro promoter in the rDNA, and extended replicative lifespan in a SIR2-dependent manner. Spt4-dependent lifespan restriction is abolished in the absence of non-coding RNA transcription at the E-pro locus. The amount of Spt4 increases and its function becomes more important as cells age. These findings suggest that Spt4 is a promising aging factor that accelerates cellular senescence through rDNA instability driven by non-coding RNA transcription.


Asunto(s)
Senescencia Celular , Proteínas de Saccharomyces cerevisiae , Genes de ARNr/genética , ADN Ribosómico/genética , Senescencia Celular/genética , Saccharomyces cerevisiae/genética , Saccharomyces cerevisiae/metabolismo , Proteínas de Saccharomyces cerevisiae/genética , Proteínas de Saccharomyces cerevisiae/metabolismo , ARN no Traducido/genética , Transcripción Genética , Proteínas Nucleares/metabolismo , Factores de Elongación Transcripcional/genética
18.
Leg Med (Tokyo) ; 63: 102257, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37068342

RESUMEN

In forensic pathology, it is important to detect and recover as evidence residual metal particles and projectiles when evaluating potential gunshot wounds. This process can be challenging when the bullets are fragmented. This report presents our experience using multiple modalities to analyze the wound of an illegally killed Japanese serow (Capricornis crispus) found in a mountainous region without its head and hind limbs. We performed postmortem computed tomography (PMCT) and necropsy that showed a distant-range gunshot wound of the neck likely created by a centerfire rifle. A postmortem cut through the neck and absent head precluded a complete evaluation. To determine the composition of the metal-like fragments in the neck, sampling and metal analysis were performed in two ways. Samples extracted from the exposed wound surface without CT guidance were analyzed directly using inductively coupled plasma mass spectrometry (ICP-MS). Samples from the bone, muscles, and cervical cord extracted under CT guidance were analyzed using x-ray analytic microscopy (XGT-9000, HORIBA, Kyoto, Japan). In wound surface samples, silicon and iron were detected as the main components on ICP-MS, suggesting that the materials were gravel. The samples taken under CT guidance and analyzed with XGT-9000 revealed that the high-density CT areas were mainly composed of lead. Combining CT-guided sample extraction and XGT-9000 can be useful for retrieving true projectile fragments and avoiding the confusion created by erroneously sampling non-projectile surface materials.


Asunto(s)
Armas de Fuego , Heridas por Arma de Fuego , Humanos , Heridas por Arma de Fuego/diagnóstico por imagen , Heridas por Arma de Fuego/patología , Microscopía , Rayos X , Metales , Tomografía Computarizada por Rayos X , Balística Forense
19.
Heart Rhythm ; 20(10): 1370-1377, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37414109

RESUMEN

BACKGROUND: Omnipolar technology (OT) was recently proposed to generate electroanatomic voltage maps with orientation-independent electrograms. We describe the first cohort of patients undergoing ventricular tachycardia (VT) ablation guided by OT. OBJECTIVE: The purpose of this study was to compare omnipolar and bipolar high-density maps with regard to voltage amplitude, late potential (LP) annotation, and isochronal late activation mapping distribution. METHODS: A total of 24 patients (16 [66%] ischemic cardiomyopathy and 12 [50%] redo cases) underwent VT ablation under OT guidance. Twenty-seven sinus rhythm substrate maps and 10 VT activation maps were analyzed. Omnipolar and bipolar (HD Wave Solution algorithm, Abbott, Abbott Park, IL) voltages were compared. Areas of LPs were correlated with the VT isthmus areas, and late electrogram misannotation was evaluated. Deceleration zones based on isochronal late activation maps were analyzed by 2 blinded operators and compared to the VT isthmuses. RESULTS: OT maps had higher point density (13.8 points/cm2 vs 8.0 points/cm2). Omnipolar points had 7.1% higher voltages than bipolar points within areas of dense scar and border zone. The number of misannotated points was significantly lower for OT maps (6.8% vs 21.9%; P = .01), showing comparable sensitivity (53% vs 59%) but higher specificity (79% vs 63%). The sensitivity and specificity of detection of the VT isthmus in the deceleration zones were, respectively, 75% and 65% for OT and 35% and 55% for bipolar mapping. At 8.4 months, 71% freedom from VT recurrence was achieved. CONCLUSION: OT is a valuable tool for guiding VT ablation, providing more accurate identification of LPs and isochronal crowding due to slightly higher voltages.

20.
Gan To Kagaku Ryoho ; 39(3): 347-50, 2012 Mar.
Artículo en Japonés | MEDLINE | ID: mdl-22421759

RESUMEN

IPMN is a slow-growing tumor and has a good prognosis, but is very often associated with a high incidence of pancreatic ductalcarcinoma(DC). Unlike IPMN, DC progresses rapidly, and has a poor prognosis. However, DC concomitant with IPMN has a better prognosis than DC without IPMN. The reason for the good prognosis of the former is undetermined, but perhaps it is the early detection of DC or its not so malignant behavior. It is important to thoroughly examine the entire pancreas for the potentialco -occurrence of DC in patients with IPMN.


Asunto(s)
Adenocarcinoma Mucinoso/patología , Carcinoma Ductal Pancreático/patología , Carcinoma Papilar/patología , Neoplasias Pancreáticas/patología , Adenocarcinoma Mucinoso/epidemiología , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma Ductal Pancreático/epidemiología , Carcinoma Papilar/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Invasividad Neoplásica , Neoplasias Pancreáticas/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA