Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Toxicol Appl Pharmacol ; 289(2): 240-50, 2015 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-26476918

RESUMEN

Quantum dots (QDs) are engineered semiconductor nanoparticles with unique physicochemical properties that make them potentially useful in clinical, research and industrial settings. However, a growing body of evidence indicates that like other engineered nanomaterials, QDs have the potential to be respiratory hazards, especially in the context of the manufacture of QDs and products containing them, as well as exposures to consumers using these products. The overall goal of this study was to investigate the role of mouse strain in determining susceptibility to QD-induced pulmonary inflammation and toxicity. Male mice from 8 genetically diverse inbred strains (the Collaborative Cross founder strains) were exposed to CdSe-ZnS core-shell QDs stabilized with an amphiphilic polymer. QD treatment resulted in significant increases in the percentage of neutrophils and levels of cytokines present in bronchoalveolar lavage fluid (BALF) obtained from NOD/ShiLtJ and NZO/HlLtJ mice relative to their saline (Sal) treated controls. Cadmium measurements in lung tissue indicated strain-dependent differences in disposition of QDs in the lung. Total glutathione levels in lung tissue were significantly correlated with percent neutrophils in BALF as well as with lung tissue Cd levels. Our findings indicate that QD-induced acute lung inflammation is mouse strain dependent, that it is heritable, and that the choice of mouse strain is an important consideration in planning QD toxicity studies. These data also suggest that formal genetic analyses using additional strains or recombinant inbred strains from these mice could be useful for discovering potential QD-induced inflammation susceptibility loci.


Asunto(s)
Compuestos de Cadmio/toxicidad , Pulmón/efectos de los fármacos , Neumonía/inducido químicamente , Puntos Cuánticos/toxicidad , Compuestos de Selenio/toxicidad , Sulfuros/toxicidad , Compuestos de Zinc/toxicidad , Animales , Líquido del Lavado Bronquioalveolar/inmunología , Análisis por Conglomerados , Citocinas/metabolismo , Predisposición Genética a la Enfermedad , Glutatión/metabolismo , Herencia , Pulmón/inmunología , Pulmón/metabolismo , Macrófagos/efectos de los fármacos , Macrófagos/inmunología , Masculino , Ratones , Ratones de la Cepa 129 , Ratones Endogámicos C57BL , Ratones Endogámicos NOD , Infiltración Neutrófila/efectos de los fármacos , Neutrófilos/efectos de los fármacos , Neutrófilos/inmunología , Fenotipo , Neumonía/genética , Neumonía/inmunología , Neumonía/metabolismo , Factores de Riesgo , Especificidad de la Especie , Factores de Tiempo
2.
EGEMS (Wash DC) ; 6(1): 8, 2018 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-29881766

RESUMEN

BACKGROUND: The availability of high fidelity electronic health record (EHR) data is a hallmark of the learning health care system. Washington State's Surgical Care Outcomes and Assessment Program (SCOAP) is a network of hospitals participating in quality improvement (QI) registries wherein data are manually abstracted from EHRs. To create the Comparative Effectiveness Research and Translation Network (CERTAIN), we semi-automated SCOAP data abstraction using a centralized federated data model, created a central data repository (CDR), and assessed whether these data could be used as real world evidence for QI and research. OBJECTIVES: Describe the validation processes and complexities involved and lessons learned. METHODS: Investigators installed a commercial CDR to retrieve and store data from disparate EHRs. Manual and automated abstraction systems were conducted in parallel (10/2012-7/2013) and validated in three phases using the EHR as the gold standard: 1) ingestion, 2) standardization, and 3) concordance of automated versus manually abstracted cases. Information retrieval statistics were calculated. RESULTS: Four unaffiliated health systems provided data. Between 6 and 15 percent of data elements were abstracted: 51 to 86 percent from structured data; the remainder using natural language processing (NLP). In phase 1, data ingestion from 12 out of 20 feeds reached 95 percent accuracy. In phase 2, 55 percent of structured data elements performed with 96 to 100 percent accuracy; NLP with 89 to 91 percent accuracy. In phase 3, concordance ranged from 69 to 89 percent. Information retrieval statistics were consistently above 90 percent. CONCLUSIONS: Semi-automated data abstraction may be useful, although raw data collected as a byproduct of health care delivery is not immediately available for use as real world evidence. New approaches to gathering and analyzing extant data are required.

3.
Ann Thorac Surg ; 101(1): 274-9, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26298169

RESUMEN

BACKGROUND: Current eligibility criteria for lung cancer screening may underestimate the risk of malignancy for some individuals. We compared the predicted risk of lung cancer among patients who would have met screening criteria to those who would not have despite being at moderate-risk. METHODS: A retrospective cohort study of resected lung cancer patients was performed. The screen eligible group was based on criteria provided by the United States Preventive Services Task Force; age 55 to 80 and a 30 or greater pack-year smoking history. The screen ineligible group was based on criteria provided by the National Comprehensive Cancer Network for a moderate-risk individual not recommended screening; age greater than 50 years, greater than 20 pack-year smoking history, and no history of asbestos exposure or chronic obstructive pulmonary disease. A recently validated risk-prediction model was used to compare the risk of lung cancer across eligibility groups based on measured and imputed patient-level variables. RESULTS: Screen ineligible patients (n = 88) had a lower estimated probability of lung cancer than screen eligible patients (n = 419); 1.3% versus 3.1%, p value less than 0.001. However, 20% of screen ineligible patients had a predicted probability of lung cancer greater than or equal to the prevalence of lung cancer (3.7%) among National Lung Screening Trial participants; 17% of screen ineligible patients had a predicted probability of lung cancer greater than or equal to the American Association for Thoracic Surgery threshold (5%) defining high-risk individuals. CONCLUSIONS: Current eligibility criteria for lung cancer screening underestimate the risk of lung cancer for some individuals who might benefit from lung cancer screening.


Asunto(s)
Neoplasias Pulmonares/epidemiología , Tamizaje Masivo/métodos , Neumonectomía , Medición de Riesgo/métodos , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/cirugía , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Estados Unidos/epidemiología
4.
J Thorac Cardiovasc Surg ; 150(4): 796-803.e1-2, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26320776

RESUMEN

OBJECTIVE: Vascular endothelial growth factors (VEGFs) C and D are biologically rational markers of nodal disease that could improve the accuracy of lung cancer staging. We hypothesized that these biomarkers would improve the ability of positron emission tomography (PET) to predict nodal disease among patients with suspected or confirmed non-small cell lung cancer (NSCLC). METHODS: A cross-sectional study (2010-2013) was performed of patients prospectively enrolled in a lung nodule biorepository, staged by computed tomography (CT) and PET, and who underwent pathologic nodal evaluation. Enzyme-linked immunosorbent assay was used to measure biomarker levels in plasma from blood drawn before anesthesia. Likelihood ratio testing was used to compare the following logistic regression prediction models: ModelPET, ModelPET/VEGF-C, ModelPET/VEGF-D, and ModelPET/VEGF-C/VEGF-D. To account for 5 planned pairwise comparisons, P values <.01 were considered significant. RESULTS: Among 62 patients (median age, 67 years; 48% men; 87% white; and 84% NSCLC), 58% had fluorodeoxyglucose uptake in hilar and/or mediastinal lymph nodes. The prevalence of pathologically confirmed lymph node metastases was 40%. Comparisons of prediction models revealed the following: ModelPET/VEGF-C versus ModelPET (P = .0069), ModelPET/VEGF-D versus ModelPET (P = .1886), ModelPET/VEGF-C/VEGF-D versus ModelPET (P = .0146), ModelPET/VEGF-C/VEGF-D versus ModelPET/VEGF-C (P = .2818), and ModelPET/VEGF-C/VEGF-D versus ModelPET/VEGF-D (P = .0095). In ModelPET/VEGF-C, higher VEGF-C levels were associated with an increased risk of nodal disease (odds ratio, 2.96; 95% confidence interval, 1.26-6.90). CONCLUSIONS: Plasma levels of VEGF-C complemented the ability of PET to predict nodal disease among patients with suspected or confirmed NSCLC. VEGF-D did not improve prediction.


Asunto(s)
Biomarcadores de Tumor/sangre , Carcinoma de Pulmón de Células no Pequeñas/sangre , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Neoplasias Pulmonares/sangre , Neoplasias Pulmonares/diagnóstico por imagen , Tomografía de Emisión de Positrones , Factor C de Crecimiento Endotelial Vascular/sangre , Factor D de Crecimiento Endotelial Vascular/sangre , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Pulmón de Células no Pequeñas/secundario , Estudios Transversales , Femenino , Humanos , Neoplasias Pulmonares/patología , Metástasis Linfática , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos
5.
Nanotoxicology ; 7(2): 181-91, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22264017

RESUMEN

Because of their unique optical properties, quantum dots (QDs) have become a preferred system for ultrasensitive detection and imaging. However, since QDs commonly contain Cd and other heavy metals, concerns have been raised regarding their toxicity. QDs are thus commonly synthesised with a ZnS cap structure and/or coated with polymeric stabilisers. We recently synthesised amphiphilic polymer-coated tri-n-octylphosphine oxide - poly(maleic anhydride-alt-1-tetradecene (TOPO-PMAT) QDs, which are highly stable in aqueous environments. The effects of these QDs on viability and stress response in five cell lines of mouse and human origins are reported here. Human and mouse macrophages and human kidney cells readily internalised these QDs, resulting in modest toxicity. TOPO-PMAT QD exposure was highly correlated with the induction of the stress response protein heme oxygenase-1 (HMOX1). Other stress biomarkers (glutamate cysteine ligase modifier subunit, NAD(P)H, necrosis) were only moderately affected. HMOX1 may thus be a useful biomarker of TOPO-QDOT QD exposure across cell types and species.


Asunto(s)
Compuestos de Cadmio/toxicidad , Hemo-Oxigenasa 1/metabolismo , Proteínas de la Membrana/metabolismo , Polímeros/toxicidad , Puntos Cuánticos , Compuestos de Selenio/toxicidad , Sulfuros/toxicidad , Tensoactivos/toxicidad , Compuestos de Zinc/toxicidad , Animales , Biomarcadores/metabolismo , Western Blotting , Compuestos de Cadmio/metabolismo , Línea Celular , Supervivencia Celular/efectos de los fármacos , Análisis por Conglomerados , Relación Dosis-Respuesta a Droga , Humanos , Peroxidación de Lípido/efectos de los fármacos , Ratones , Microscopía Confocal , Necrosis , Compuestos Organofosforados/toxicidad , Estrés Oxidativo/efectos de los fármacos , Polímeros/metabolismo , Compuestos de Selenio/metabolismo , Compuestos de Sulfhidrilo/metabolismo , Sulfuros/metabolismo , Tensoactivos/metabolismo , Compuestos de Zinc/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA