Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Arch Otorhinolaryngol ; 281(4): 1717-1734, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37917166

RESUMEN

PURPOSE: This study aimed to determine whether preoperative depressiveness, stress, and personality influence quality of life (QOL) after cochlear implant (CI) surgery. METHODS: In this prospective study, 79 patients undergoing CI surgery were evaluated preoperatively and 12 months postoperatively. Disease-specific QOL was assessed with the Nijmegen Cochlear Implant Questionnaire (NCIQ) and general QOL with the WHOQOL-BREF. Depressiveness and stress were assessed with the Patient Health Questionnaire (PHQ-D). The Charlson Comorbidity Index (CCI) was used to classify comorbidities. The Big Five Personality Test (B5T) was used to assess the basic personality dimensions. Speech comprehension was evaluated in quiet with the Freiburg monosyllable test and in noise with the Oldenburg sentence test. RESULTS: After CI surgery, the total NCIQ score improved significantly (Δ 17.1 ± 14.7, p < 0.001). General QOL (WHOQOL-BREF, Δ 0.4 ± 9.9, p = 0.357), stress (Δ 0.25 ± 3.21, p = 0.486), and depressiveness (Δ 0.52 ± 3.21, p = 0.121) were unaffected by CI surgery. Patients without elevated depressiveness (p < 0.01) or stress (p < 0.001) had significantly better total NCIQ scores. The results of the multiple regression analyses show that, after adjusting for the CCI, personality, age, and mental health stress (ß = - 0.495, p < 0.001) was significantly associated with postoperative NCIQ outcome scores. Depressiveness and neuroticism had the strongest influence on the generic QOL (ß = - 0.286 and ß = - 0.277, p < 0.05). CONCLUSION: Stress symptoms and personality traits are significant predictive factors for disease-specific QOL, as well as hearing status. This should be considered in the preoperative consultation and in optimizing the rehabilitation process.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Trastorno Depresivo , Percepción del Habla , Humanos , Implantación Coclear/métodos , Calidad de Vida , Estudios Prospectivos , Personalidad , Encuestas y Cuestionarios
2.
HNO ; 72(Suppl 1): 25-32, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37656221

RESUMEN

BACKGROUND: Patients with a cochlear implant (CI) should be evaluated for a new speech processor every 6 years. The aim of this analysis was to assess the subjective and audiological benefit of upgrades. METHODS: Speech understanding and subjective benefit were analyzed in 99 patients with the old and the new speech processor after 4 weeks of wearing. Speech understanding was assessed using the Freiburg monosyllabic test in quiet (FBE) at 65 dB and 80 dB, and the Oldenburg Sentence Test (OLSA) at 65 dB noise with adaptive speech sound level. The Abbreviated Profile of Hearing Aid Benefit (APHAB) was used to assess subjective hearing impairment, and the Audio Processor Satisfaction Questionnaire (APSQ) was used to assess subjective satisfaction. RESULTS: The speech processor upgrade resulted in a significant improvement of speech understanding in quiet at 65 dB (mean difference 8.9 ± 25.9 percentage points, p < 0.001) and 80 dB (mean difference 8.1 ± 29.7 percentage points, p < 0.001) and in noise (mean difference 3.2 ± 10.7 dB signal-to-noise ratio [S/N], p = 0.006). Using the APHAB, a significant improvement (mean difference 0.07 ± 0.16, p < 0.001) in hearing impairment was demonstrated in all listening situations. The APSQ showed significantly higher patient satisfaction with the new speech processor (mean difference 0.42 ± 1.26, p = 0.006). A comparative assessment of the benefit based on subjective and speech audiometric results identified a proportion of patients (35-42%) who subjectively benefited from the upgrade but had no measurable benefit based on speech audiometry. CONCLUSION: There was a significant improvement in audiologically measurable and subjectively reflected speech understanding and patient satisfaction after the upgrade. In patients with only a small improvement in audiologically measurable speech understanding, the subjective benefit should also be assessed with validated measurement instruments in order to justify an upgrade to the payers in the health sector.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva , Percepción del Habla , Humanos , Habla , Implantación Coclear/métodos , Pérdida Auditiva/diagnóstico , Pérdida Auditiva/cirugía , Medición de Resultados Informados por el Paciente
3.
HNO ; 72(Suppl 1): 33-42, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37792097

RESUMEN

BACKGROUND: With the Chronic Ear Survey (CES), a validated measurement instrument for the assessment of disease-specific health-related quality of life (HRQoL) has been available internationally since 2000. The aim of this study was to provide a validated German version of this international instrument and to compare it with the German Chronic Otitis Media Outcome Test 15 (COMOT-15). METHODOLOGY: The CES was translated into German via a forward-backward translation process. For validation, 79 patients with COM undergoing middle ear surgery were prospectively included. HRQoL was determined preoperatively and 6 months postoperatively using the CES and the COMOT-15. Pure tone audiometry was also performed at both measurement time points. In the control examination, an additional retrospective assessment of the preoperative situation was additionally performed using the CES and the COMOT-15 to assess the response shift. The determined psychometric characteristics were internal consistency, test-retest reliability, discrimination validity, agreement validity, responsiveness, and response shift for both measurement instruments. Convergent validity of both measurement instruments was assessed using linear regression. RESULTS: On the basis of the CES, patients with COM could be reliably distinguished from patients with healthy ears. The CES showed satisfactory reliability with high internal consistency (Cronbach α 0.65-0.85) and high retest reliability (r > 0.8). The global assessment of HRQoL impairment correlated very well with the scores of the CES (r = 0.51). In addition, it showed a high sensitivity to change (standardized response mean -0.86). Compared to the COMOT-15, it showed a lower response shift (effect size -0.17 vs. 0.44). Both measurement instruments correlated only slightly with air conduction hearing threshold (r = 0.29 and r = 0.24, respectively). The concordant validity of both measurement instruments was high (r = 0.68). CONCLUSION: The German version of the CES shows satisfactory psychometric characteristics, so that its use can be recommended. The CES focuses on the influence of ear symptoms on HRQoL, whereas the COMOT-15 also includes functional and psychological aspects. Due to only minor response shift effects, the CES is particularly suitable for studies with multiple repeat measurements.


Asunto(s)
Otitis Media , Calidad de Vida , Humanos , Psicometría , Reproducibilidad de los Resultados , Estudios Retrospectivos , Encuestas y Cuestionarios , Lenguaje
4.
Laryngorhinootologie ; 103(4): 252-260, 2024 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-38565108

RESUMEN

Language processing can be measured objectively using late components in the evoked brain potential. The most established component in this area of research is the N400 component, a negativity that peaks at about 400 ms after stimulus onset with a centro-parietal maximum. It reflects semantic processing. Its presence, as well as its temporal and quantitative expression, allows to conclude about the quality of processing. It is therefore suitable for measuring speech comprehension in special populations, such as cochlear implant (CI) users. The following is an overview of the use of the N400 component as a tool for studying language processes in CI users. We present studies with adult CI users, where the N400 reflects the quality of speech comprehension with the new hearing device and we present studies with children where the emergence of the N400 component reflects the acquisition of their very first vocabulary.


Asunto(s)
Implantes Cocleares , Percepción del Habla , Adulto , Niño , Femenino , Humanos , Masculino , Comprensión/fisiología , Electroencefalografía , Potenciales Evocados/fisiología , Lenguaje , Desarrollo del Lenguaje , Semántica , Percepción del Habla/fisiología
5.
Ear Hear ; 44(1): 135-145, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35913925

RESUMEN

OBJECTIVES: The active middle ear implant, Vibrant Soundbridge (VSB), can be implanted with a variety of couplers. Hearing outcome after implantation has been investigated in both temporal bone (TB) experiments and patient studies, but the relationship between experimental and clinical data is still weak in the literature. Therefore, experimental data from TB experiments should be compared with patient data in a retrospective study, in which the floating mass transducer is used with couplers of the third generation. Actuator coupling structures included the long (LP coupler) and short (SP coupler) incus process, the stapes head (Clip coupler), and the round window membrane (RW soft coupler). METHODS: In the TB experiments, the sound transmission after vibroplasty on the above-mentioned actuator coupling structures was determined in 32 specimens by means of laser Doppler vibrometry on the stapes footplate. Data of 69 patients were analyzed. The main target audiometric parameters were the postoperative aided word recognition score (WRS) in the free field at 65 dB SPL (WRS 65 dB in %), the preoperative and postoperative pure-tone average (PTA4, including the frequencies 0.5, 1, 2, and 4 kHz) of the bone conduction hearing threshold (PTA4BC), the aided postoperative air conduction hearing threshold in the free field (PTA4FF) and the direct threshold (Vibrogram) at least 6 months postoperatively. The coupling efficiency of the actuator (Vibrogram-PTA4BC) as well as the effective hearing gain (PTA4FF-PTA4BC) was compared between the couplers. RESULTS: The analysis in the main speech range (0.5-4 kHz) indicated that in the TB experiments, the LP coupler tends to have the best coupling quality at low frequencies (500-1000 Hz). This was up to 15 dB above the worst actuator (RW soft coupler). However, the results missed the significance level ( p > 0.05). In the high frequencies (2000-4000 Hz), the Clip coupler showed the best coupling quality. This was 15 dB above the worst actuator (SP coupler). However, the results missed the significance level ( p > 0.05), too. The postoperative WRS at 65 dB SPL and the postoperative PTA4FF were independent of the actuator coupling structure. The PTA4BC was stable at 6 months postoperatively. For the PTA4 of the coupling efficiency, there were no significant differences between the actuator coupling structures (LP 8.9 dB ± 12.9; SP 9.5 ± 6.5 dB; Clip 5.2 ± 10.5 dB; RW 12.7 ± 11.0 dB). However, the tendential inferiority of the RW soft coupler with regard to transmission in the low-frequency range and the tendential superiority of the Clip coupler in the high-frequency range that have already been displayed experimentally could be confirmed in the clinical results. However, the clinical results missed the significance level, too ( p > 0.05). CONCLUSIONS: In vivo, there are no significant differences in the postoperative outcome stratified according to coupling the target structure. The differences known from the experimental setting were repressed by individual biasing factors. However, to ensure sufficient postoperative speech intelligibility, the frequency-specific transmission behavior of the couplers should be taken into account when setting the indication for VSB implantation.


Asunto(s)
Perdida Auditiva Conductiva-Sensorineural Mixta , Prótesis Osicular , Humanos , Estudios Retrospectivos , Audición , Hueso Temporal/cirugía , Resultado del Tratamiento
6.
Eur Arch Otorhinolaryngol ; 280(11): 4835-4844, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37173536

RESUMEN

PURPOSE: During COVID-19, a fully digital course was established for teaching and assessing the psychomotor skills of clinical head and neck examination. Influence of different digital teaching formats was investigated. METHODS: The students (n = 286) received disposable instruments, a manual, and instructional videos for the examination. 221 students additionally received 45 min of interactive teleteaching. After 5 days of practice, all students were required to submit a video of their examination and report their spent practice time. The assessment was carried out using a checklist which was already established in presence teaching. RESULTS: The average score achieved by digital teaching was 86%. Previously published data show that presence teaching achieved 94%. With a teleteaching unit the total score was significantly better than without (87% vs 83%). Teleteaching leads to a significant positive correlation between practice time and total score. Without teleteaching there is a negative correlation. After the same practice time, presence teaching leads to better total scores than digital teaching. CONCLUSION: Digital teaching and assessing of a complex psychomotor skill is possible. Interactive teaching methods increase learning success. Nevertheless, presence teaching seems to be better at teaching these skills. The results can provide a basis for developing hybrid teaching models.


Asunto(s)
COVID-19 , Pandemias , Humanos , Aprendizaje , Examen Físico , Enseñanza
7.
Int J Audiol ; : 1-8, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37656611

RESUMEN

OBJECTIVE: The goal of this study was to determine open field stapedius reflex thresholds (oSRTs) in CI patients with fittings based on subjective loudness ratings. A further objective was to compare these oSRTs and those of eSRT-based fittings that are similar to the oSRTs of normal hearing. DESIGN: Impedance measurements of the ear drum were taken while subjects were wearing their audio processors. The stapedius reflex was elicited by electrical stimulation transmitted through the activated CI system in response to an acoustic stimulus presented in the free sound field. STUDY SAMPLE: Subjects were 50 experienced CI users (n = 57 ears) with CI fittings based on subjective loudness scaling. RESULTS: A reference range for the oSRTs was defined that was identified in CI patients with eSRT-based fittings. Sound levels for stapedius reflex detection were inside the reference target range in 70% of the cases, below the reference range (i.e. down to 40 dB HL) in 20% of the cases, and above the reference range in 10% of the cases. CONCLUSION: Stapedius reflex detection in a free sound field may help detect fittings with too high or too low stimulation levels that might reduce audiological performance.

8.
HNO ; 71(9): 583-591, 2023 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-37540233

RESUMEN

BACKGROUND: Patients with a cochlear implant (CI) should be evaluated for a new speech processor every 6 years. The aim of this analysis was to assess the subjective and audiological benefit of upgrades. METHODS: Speech understanding and subjective benefit were analyzed in 99 patients with the old and the new speech processor after 4 weeks of wearing. Speech understanding was assessed using the Freiburg monosyllabic test in quiet (FBE) at 65 dB and 80 dB, and the Oldenburg Sentence Test (OLSA) at 65 dB noise with adaptive speech sound level. The Abbreviated Profile of Hearing Aid Benefit (APHAB) was used to assess subjective hearing impairment, and the Audio Processor Satisfaction Questionnaire (APSQ) was used to assess subjective satisfaction. RESULTS: The speech processor upgrade resulted in a significant improvement of speech understanding in quiet at 65 dB (mean difference 8.9 ± 25.9 percentage points, p < 0.001) and 80 dB (mean difference 8.1 ± 29.7 percentage points, p < 0.001) and in noise (mean difference 3.2 ± 10.7 dB signal-to-noise ratio [S/N], p = 0.006). Using the APHAB, a significant improvement (mean difference 0.07 ± 0.16, p < 0.001) in hearing impairment was demonstrated in all listening situations. The APSQ showed significantly higher patient satisfaction with the new speech processor (mean difference 0.42 ± 1.26, p = 0.006). A comparative assessment of the benefit based on subjective and speech audiometric results identified a proportion of patients (35-42%) who subjectively benefited from the upgrade but had no measurable benefit based on speech audiometry. CONCLUSION: There was a significant improvement in audiologically measurable and subjectively reflected speech understanding and patient satisfaction after the upgrade. In patients with only a small improvement in audiologically measurable speech understanding, the subjective benefit should also be assessed with validated measurement instruments in order to justify an upgrade to the payers in the health sector.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva , Percepción del Habla , Humanos , Habla , Implantación Coclear/métodos , Pérdida Auditiva/diagnóstico , Pérdida Auditiva/cirugía , Medición de Resultados Informados por el Paciente
9.
HNO ; 71(9): 572-582, 2023 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-37540235

RESUMEN

BACKGROUND: With the Chronic Ear Survey (CES), a validated measurement instrument for the assessment of disease-specific health-related quality of life (HRQoL) has been available internationally since 2000. The aim of this study was to provide a validated German version of this international instrument and to compare it with the German Chronic Otitis Media Outcome Test 15 (COMOT-15). METHODOLOGY: The CES was translated into German via a forward-backward translation process. For validation, 79 patients with COM undergoing middle ear surgery were prospectively included. HRQoL was determined preoperatively and 6 months postoperatively using the CES and the COMOT-15. Pure tone audiometry was also performed at both measurement time points. In the control examination, an additional retrospective assessment of the preoperative situation was additionally performed using the CES and the COMOT-15 to assess the response shift. The determined psychometric characteristics were internal consistency, test-retest reliability, discrimination validity, agreement validity, responsiveness, and response shift for both measurement instruments. Convergent validity of both measurement instruments was assessed using linear regression. RESULTS: On the basis of the CES, patients with COM could be reliably distinguished from patients with healthy ears. The CES showed satisfactory reliability with high internal consistency (Cronbach α 0.65-0.85) and high retest reliability (r > 0.8). The global assessment of HRQoL impairment correlated very well with the scores of the CES (r = 0.51). In addition, it showed a high sensitivity to change (standardized response mean -0.86). Compared to the COMOT-15, it showed a lower response shift (effect size -0.17 vs. 0.44). Both measurement instruments correlated only slightly with air conduction hearing threshold (r = 0.29 and r = 0.24, respectively). The concordant validity of both measurement instruments was high (r = 0.68). CONCLUSION: The German version of the CES shows satisfactory psychometric characteristics, so that its use can be recommended. The CES focuses on the influence of ear symptoms on HRQoL, whereas the COMOT-15 also includes functional and psychological aspects. Due to only minor response shift effects, the CES is particularly suitable for studies with multiple repeat measurements.


Asunto(s)
Otitis Media , Calidad de Vida , Humanos , Psicometría , Reproducibilidad de los Resultados , Estudios Retrospectivos , Lenguaje , Encuestas y Cuestionarios
10.
Laryngorhinootologie ; 102(8): 619-628, 2023 08.
Artículo en Alemán | MEDLINE | ID: mdl-37536333

RESUMEN

Chronic mesotympanal otitis media (CMOM) is a well-developed clinical presentation that is established in diagnostics and therapy. On closer inspection, however, this principle cannot be confirmed in all its facets. Already the physiology and pathophysiology of the middle ear mucosa leave questions unanswered, starting with the distribution of the ciliated epithelium in the middle ear and mastoid to the function of gas exchange.In addition, there are new diagnostic and therapeutic approaches. In the future, optical coherence tomography could help to determine the status of the middle ear mucosa. In addition, there are new findings on the effectiveness of local and systemic antibiotics as well as antiseptics in chronic otorrhea. Other new developments include minimally invasive surgical procedures using endoscopic techniques. All this gives reason to provide an update on the topic of chronic mesotympanal otitis media, which should contribute in preparation for the specialist examination or refreshing.Basics of physiology and pathophysiology as well as new diagnostic approaches and medical treatment were covered in Part 1 of this paper. In Part 2, in addition to established methods, new developments in surgical therapy with minimally invasive surgical procedures are described in more detail.


Asunto(s)
Otitis Media , Humanos , Otitis Media/diagnóstico , Otitis Media/tratamiento farmacológico , Otitis Media/cirugía , Oído Medio , Antibacterianos/uso terapéutico , Apófisis Mastoides , Enfermedad Crónica
11.
Laryngorhinootologie ; 102(10): 777-791, 2023 10.
Artículo en Alemán | MEDLINE | ID: mdl-37793378

RESUMEN

Chronic mesotympanal otitis media (CMOM) is a well-developed clinical presentation that is established in diagnostics and therapy. On closer inspection, however, this principle cannot be confirmed in all its facets. Already the physiology and pathophysiology of the middle ear mucosa leave questions unanswered, starting with the distribution of the ciliated epithelium in the middle ear and mastoid to the function of gas exchange.In addition, there are new diagnostic and therapeutic approaches. In the future, optical coherence tomography could help to determine the status of the middle ear mucosa. In addition, there are new findings on the effectiveness of local and systemic antibiotics as well as antiseptics in chronic otorrhea. Other new developments include minimally invasive surgical procedures using endoscopic techniques. All this gives reason to provide an update on the topic of chronic mesotympanal otitis media, which should contribute in preparation for the specialist examination or refreshing.Basics of physiology and pathophysiology as well as new diagnostic approaches and medical treatment were covered in Part 1 of this paper. In Part 2, in addition to established methods, new developments in surgical therapy with minimally invasive surgical procedures are described in more detail.


Asunto(s)
Otitis Media , Humanos , Otitis Media/diagnóstico , Otitis Media/cirugía , Otitis Media/tratamiento farmacológico , Oído Medio , Antibacterianos/uso terapéutico , Apófisis Mastoides , Enfermedad Crónica
12.
Laryngorhinootologie ; 102(6): 412-415, 2023 06.
Artículo en Alemán | MEDLINE | ID: mdl-37267964

RESUMEN

The 2018 template for otorhinolaryngology specialist training of the German Medical Association is increasingly implemented by the federal associations. In this regard, the German Society recommended an otorhinolaryngology resident training plan for Otorhinolaryngology, Head and Neck Surgery (DGHNO-KHC) together with the Professional Association of German Otorhinolaryngologists as a suggested guideline for the federal medical associations. In this context, the state medical associations currently work on criteria on the basis of which otorhinolaryngologists and their training institutions can be granted authority for such a certified otorhinolaryngology resident training program.The DGHNO-KHC last made recommendations for the granting of authorizations for specialist training in otorhinolaryngology in 1999. Many contents have changed as a result of the 2018 model specialist training regulations. Therefore, a scientifically formulated proposal for the granting of continuing education authorizations is herewith provided as recommendation to the federal state medical associations.


Asunto(s)
Otolaringología , Humanos , Otolaringología/educación , Especialización , Alemania
13.
Laryngorhinootologie ; 101(S 01): S3-S35, 2022 05.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-35605611

RESUMEN

The provision of implantable hearing aids represents an area with high development and innovation potential. On the one hand, this review article provides an overview of current indication criteria for the treatment with active middle ear implants. On the other hand, outcome parameters as well as functional results after implantation of active middle ear implants are demonstrated and discussed. The focus is mainly placed on audiological results as well as the subjective health status. "Patient Reported Outcome Measures" (PROMs) have become an integral part of the evaluation of hearing implant treatment. Due to low evidence level criteria, the study situation regarding audiological as well as subjective outcome parameters is not satisfactory. The lack of an international consensus on accepted outcome parameters makes a meta-analytical analysis of results immensely difficult. In the studies published to date, patients with sensorineural hearing loss and patients with conductive or mixed hearing loss offered better speech recognition after implantation of an active middle ear implant compared to conventional hearing aids. Current analyses show a significant improvement in general as well as hearing-specific quality of life after implantation of an active middle ear implant. To date, no validated, hearing-specific quality-of-life measurement instruments exist for assessing the success of fitting in children. Especially in children with complex malformations of the outer ear and the middle ear, excellent audiological results were shown. However, these results need to be substantiated by quality-of-life measurements in future.


Asunto(s)
Sordera , Audífonos , Pérdida Auditiva Sensorineural , Prótesis Osicular , Percepción del Habla , Niño , Oído Medio/cirugía , Humanos , Calidad de Vida , Resultado del Tratamiento
14.
Laryngorhinootologie ; 101(6): 518-538, 2022 06.
Artículo en Alemán | MEDLINE | ID: mdl-35724922

RESUMEN

Vestibular (vestibulocochlear) schwannomas are rare, benign schwannomas of the cerebellopontine angle, the internal auditory canal, or the inner ear. They can occur with or without clinical symptoms. The most common symptoms are unilateral or side-differentiated hearing loss with or without tinnitus and balance disorders. Initial symptomatology is nonspecific in the basic functional diagnosis, raising the question of when a hearing or balance disorder should be thought of as a differential diagnosis of vestibular schwannoma and what diagnostic pathway is appropriate. This concerns not only the confirmation of the diagnosis and the recording of all dysfunctions of the involved cranial nerves in the initial basic diagnostics, but also the procedure in the course and follow-up diagnostics - especially in patients who are subject to an observation strategy. Today, imaging alone is no longer sufficient for differentiated and individualized patient counseling. Due to the increasing detection of smaller tumors on MRI and the growing proportion of nearly asymptomatic patients, a shift in thinking from pure imaging monitoring to a detailed analysis of auditory and vestibular function is timely. In this educational article, diagnostic pathways for a sufficient patient consultation will be compiled. Ultimately, functional examination techniques from follow-up and progression diagnostics will also be included.


Asunto(s)
Oído Interno , Pérdida Auditiva , Neurilemoma , Neuroma Acústico , Acúfeno , Humanos , Imagen por Resonancia Magnética/métodos , Neurilemoma/patología , Neuroma Acústico/diagnóstico , Neuroma Acústico/patología , Acúfeno/diagnóstico , Acúfeno/etiología
15.
Eur Arch Otorhinolaryngol ; 278(9): 3217-3225, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33011956

RESUMEN

PURPOSE: The aim of this study was to determine whether preoperative depressive symptoms influence health-related quality of life (HRQOL) after middle ear surgery in patients with chronic otitis media (COM). METHODS: This prospective clinical case study was conducted at a tertiary referral center. All 102 patients who had undergone middle ear surgery for COM were assessed clinically and by audiometric testing (pure tone audiometry) in pre- and postoperative settings. Disease-specific HRQOL was assessed by the validated chronic otitis media outcome test 15 (COMOT-15) and the Zurich chronic middle ear inventory (ZCMEI-21). General HRQOL was measured using the short form 36 (SF-36). Depressive symptoms were assessed using the patient health questionnaire (PHQ-D). The Charlson comorbidity index (CCI) was used to classify comorbidities. The middle ear status was determined using the ossiculoplasty outcome parameter staging (OOPS) index. RESULTS: After middle ear surgery, the total COMOT-15 and ZCMEI-21 scores improved significantly (p < 0.001). General HRQOL (total SF-36 score) was unaffected by surgery (p < 0.05). Patients without elevated depressive symptoms had significantly better total scores for the COMOT-15 (p < 0.01), ZCMEI-21 (p < 0.001), and for SF-36 (p < 0.001) postoperatively. The results of the multiple regression analyses show that, after adjusting for the OOPS, CCI, and hearing improvement, preoperative depressiveness was significantly associated with worse postoperative COMOT-15 and ZCMEI-21 outcome scores (ß = 0.425 and ß = 0.362, p < 0.001). CONCLUSION: Preoperative depressiveness was an essential predictive factor for HRQOL in patients with COM. This should be considered during patient selection to provide more suitable preoperative counseling.


Asunto(s)
Trastorno Depresivo , Otitis Media , Enfermedad Crónica , Oído Medio , Humanos , Otitis Media/complicaciones , Otitis Media/cirugía , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento , Timpanoplastia
16.
Int J Audiol ; 60(9): 695-703, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33426977

RESUMEN

OBJECTIVE: To determine the relation between stapedius reflex thresholds in cochlear implant users evoked once through direct electric stimulation on single channels (ESRT) and once through acoustic stimulation in free sound field. For comparison, stapedius reflex thresholds were obtained in free sound field in a normal-hearing control group. DESIGN: For each participant a new ESRT-based fitting was created. Stapedius reflex thresholds were obtained for this new fitting in free sound field for different loudness adjustments. Acoustic stimuli for eliciting the stapedius reflex were narrow band noise signals covering the audiometric frequency range. STUDY SAMPLE: N = 29 experienced CI users (34 ears) and N = 10 normal hearing listeners. RESULTS: ESRT-based fitting resulted in different stapedius reflex behaviour compared to normal-hearing listeners. A frequency dependence was observed. Stapedius reflex thresholds decreased with increasing centre frequencies of acoustic narrow band noise stimuli. A linear relation between upper stimulation levels on the implant channels and corresponding stapedius reflex thresholds evoked in free sound field was found. CONCLUSION: The found correlation may be a guideline for adjusting the electrical dynamic range during cochlear implant fitting. This allows the implant system to mimic the natural reflex behaviour in the best possible way and potentially avoid overstimulation.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Estimulación Eléctrica , Audición , Humanos , Reflejo , Reflejo Acústico , Estapedio
17.
Laryngorhinootologie ; 100(2): 134-145, 2021 02.
Artículo en Alemán | MEDLINE | ID: mdl-33525013

RESUMEN

Chronic rhinosinusitis (CRS) is defined as an inflammation of the nose and paranasal sinuses with prevalence of 10.9 % and by the presents of 2 or more symptoms, which last more than 12 weeks. The symptoms are nasal obstruction, nasal discharge (anterior/post nasal drip), facial pain or pressure and/or olfactory disorder. CRS has a high negative impact on an individual's quality of life. The pathogenesis is multifactorial and complex. CRS has been subclassified into 2 groups: CRS with nasal polyps (CRSwNP) and CRS without nasal polyps (CRSsNP). Regarding further knowledge of the inflammatory pathway the primary CRS is considered by endotype dominance, either type 2 or non-type 2. 80 % of the CRSwNP reveals a type 2 inflammation. The proteins, interleukin (IL)-4, IL-5, IL-13, and IgE were previously identified as key mediators in nasal polyp tissues pattern. CRSwNP is often refractory to medical and surgical management, especially in patients with asthma and aspirin intolerance. In most cases the control of the disease is a challenge. Patients with asthma but especially with Samter's triad are significantly more likely to have a recurrence of nasal polyps and undergo a second surgery following recurrence. In patients with severe CRSwNP, in whom the current standard of care including topical and oral corticosteroids, antibiotics and surgical procedures fail to control the disease, biologics can open new perspectives in treatment. They allow avoiding the possible adverse events resulting from repeated use of systemic corticosteroids and surgery. These biologics have a high impact on type 2 immune reaction and lead to a reduction of IgE as well as of local mucosal eosinophil migration and activation, resulting in a significant effect on nasal polyps, smell, quality of life and asthma comorbidity.


Asunto(s)
Productos Biológicos , Pólipos Nasales , Rinitis , Sinusitis , Productos Biológicos/uso terapéutico , Enfermedad Crónica , Humanos , Calidad de Vida , Rinitis/tratamiento farmacológico , Sinusitis/tratamiento farmacológico
18.
Laryngorhinootologie ; 100(8): 652-672, 2021 08.
Artículo en Alemán | MEDLINE | ID: mdl-34320675

RESUMEN

In childhood, inadequately rehabilitated hearing loss leads to impaired language acquisition and social, mental and emotional development. In adults, social withdrawal due to limited communication skills is often a consequence of unsatisfactory hearing rehabilitation. Therefore, in patients with profound hearing loss, the indication for cochlear implantation should be considered. Technical advances in cochlear implant development, as well as in microsurgical techniques and the rehabilitation process, have led to an expansion of indications in recent years. Adequate hearing rehabilitation is associated not only with an improvement in hearing function and speech understanding, but also with an increase in quality of life at all ages. In patients with unilateral profound hearing loss, cochlear implantation leads to an improvement of speech understanding and localization ability as well as to a reduction of the head shadow effect and tinnitus. The indication process, surgical treatment and the subsequent rehabilitation process require interprofessional cooperation in specialized centers.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Percepción del Habla , Adulto , Sordera/cirugía , Humanos , Calidad de Vida , Resultado del Tratamiento
19.
Eur Arch Otorhinolaryngol ; 277(3): 669-677, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31758308

RESUMEN

OBJECTIVES: The use of standardized outcome parameters is essential for the comparability of clinical studies. Pure-tone audiometry and speech audiometry are widely used, but there is no systematic evaluation of the outcome parameters in clinical application. Nevertheless, there is presumably a great heterogeneity especially in the field of speech audiometry. This study presents a snapshot of the current situation of documentation and usage of outcome parameters in otologic research. STUDY DESIGN: Retrospective study of existing literature analyzing common speech audiometric test material and procedure MAIN OUTCOME MEASURES: Intervention Studies from 2012 to 2016 concerning hearing ability were eligible for evaluation. Studies were analyzed with regard to study design, pathology and intervention, speech audiometric parameters, pure-tone audiometry, implementation of reporting standards and journal related data. RESULTS: 279 studies were included. Over 50% of the analyzed studies lacked proper documentation. In the remaining studies, there was a broad variance concerning the documented speech audiometric parameters, most often with a fixed presentation level of 65 dB SPL. CONCLUSION: The lack of generally used standards for reporting hearing outcomes makes it difficult to compare results of different clinical studies. An adequate description of the methods would be a first and important step in improving reports on audiological outcomes.


Asunto(s)
Audiometría del Habla/normas , Estudios Clínicos como Asunto/normas , Pérdida Auditiva/diagnóstico , Pérdida Auditiva/terapia , Evaluación de Resultado en la Atención de Salud/normas , Calidad de la Atención de Salud/normas , Audiometría de Tonos Puros/normas , Humanos , Estudios Retrospectivos
20.
Eur Arch Otorhinolaryngol ; 277(1): 55-60, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31570983

RESUMEN

PURPOSE: The primary objective of the retrospective study was to collect speech intelligibility data on children and adolescents implanted with the vibrating ossicular prosthesis (VORP) 503. METHODS: This was a retrospective, multicentre study on 55 children and adolescents from 6 German clinics aged between 5 and 17 years suffering from mixed or conductive hearing loss implanted with a VORP 503. Pre- and postoperative bone-conduction pure tone thresholds were measured at 0.5, 1, 2 and 4 kHz, and word recognition scores in the unaided and VORP 503-aided conditions using monosyllabic speech intelligibility tests measured at 65-dB sound pressure level (SPL) were determined. RESULTS: Mean pre- and postoperative bone-conduction thresholds remained unchanged, showing the preservation of inner ear hearing. Speech intelligibility assessed in quiet at 65-dB SPL improved on average from 24.5% (SD ± 25.4) unaided to 86.4% (SD ± 13.4) aided. The average improvement of 61.9% (SD ± 25.3) was clinically and statistically significant. A total of three complications were found in the medical records of 55 subjects. The responsible investigators judged these events as procedure related. CONCLUSION: The treatment of children suffering from conductive or mixed hearing loss with the VORP 503 implant demonstrates excellent aided benefit in terms of speech understanding and only minor complications.


Asunto(s)
Pérdida Auditiva Conductiva/cirugía , Perdida Auditiva Conductiva-Sensorineural Mixta/cirugía , Prótesis Osicular , Adolescente , Umbral Auditivo , Conducción Ósea/fisiología , Niño , Preescolar , Femenino , Pérdida Auditiva Conductiva/diagnóstico , Pérdida Auditiva Conductiva/fisiopatología , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Perdida Auditiva Conductiva-Sensorineural Mixta/fisiopatología , Pruebas Auditivas , Humanos , Estudios Longitudinales , Masculino , Estudios Retrospectivos , Inteligibilidad del Habla , Resultado del Tratamiento , Vibración
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA