Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39078373

RESUMEN

INTRODUCTION AND AIM: Radiotherapy in cancer patients with a pacemaker or an implantable cardioverter defibrillator might damage the device and possibly result in malfunction of the device. We aimed to examine device malfunction and change in lead parameters in this group. METHODS: The medical records of pacemaker/implantable cardioverter defibrillator patients who underwent radiotherapy at Aalborg University Hospital between July 1, 2016, and June 30, 2021, were reviewed. Treatment was planned according to risk of device malfunction, assessed using local guidelines. Bootstrap linear regression was used to identify possible differences in lead parameters depending on beam energy and anatomical location. RESULTS: One hundred nine patients with a pacemaker/implantable cardioverter defibrillator who received a total of 122 radiotherapy courses in the study period were identified. No device malfunctions or significant changes in lead parameters during radiotherapy were observed. Only the left ventricle lead threshold and impedance were found to be significantly different when compared by beam energy; however, these changes were relatively small and unlikely to be of clinical relevance. CONCLUSION: No device malfunction or clinically relevant changes in lead parameters were identified in this study, suggesting that radiotherapy of pacemaker/implantable cardioverter defibrillator patients can be regarded as safe when following relevant safety precautions.

2.
Am J Med Genet A ; 191(4): 1059-1064, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36541930

RESUMEN

Cutis laxa (CL) is a rare, inherited or acquired connective tissue disorder characterized by abnormal elastic fibers causing loose and redundant skin and a prematurely aged appearance. The syndrome has been associated with hypertension, but cases with early-onset ischemic heart disease have never been described. Here, we report a 21-year-old Danish female with activity-related shortness of breath and oedema of the lower extremities. The patient had a clinical diagnosis of autosomal dominant CL, but no genotyping had been performed prior to the index admission. The patient was diagnosed with ischemic heart disease, based on results of non-invasive cardiovascular imaging (including MRI and PET-CT) followed by invasive treatment of a critical left main coronary artery stenosis. Subsequent referral to genetic testing revealed a likely pathogenic intronic variant in ELN. This case report includes the clinical findings and relates these to known molecular mechanisms of CL.


Asunto(s)
Estenosis Coronaria , Cutis Laxo , Elastina , Femenino , Humanos , Adulto Joven , Estenosis Coronaria/diagnóstico , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/genética , Cutis Laxo/diagnóstico , Cutis Laxo/genética , Elastina/genética , Intrones/genética , Mutación , Linaje
3.
Cardiovasc Ultrasound ; 21(1): 8, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37127676

RESUMEN

AIMS: The pathophysiological effects of chronic right ventricular pacing and the role of right ventricular lead position are not well understood. Therefore, we investigated the association between left ventricular contractile dyssynchrony and pacing-induced cardiomyopathy (PICM) in patients with chronic right ventricular pacing. Furthermore, we assessed the association between right ventricular lead location and left ventricular contractile dyssynchrony. METHODS: This was a retrospective study using data from 153 pacemaker patients with normal (≥ 50%) pre-implant left ventricular ejection fraction (LVEF). Baseline and follow-up echocardiograms were analyzed, and PICM was defined as LVEF < 50% with ≥ 10% decrease in LVEF after pacemaker implantation. Relative index of contractile asymmetry (rICA), a novel strain rate-based method, was calculated to quantify left ventricular contractile dyssynchrony between opposing walls in the three apical views. Right ventricular lead position was categorized into anterior septum, posterior septum, free wall, and apex based on contrast-enhanced cardiac computed tomography. RESULTS: Forty-seven (31%) developed PICM. Overall contractile dyssynchrony, measured by mean rICA, was higher in the PICM group compared with the non-PICM group (1.19 ± 0.21 vs. 1.03 ± 0.19, p < 0.001). Left ventricular anterior-inferior dyssynchrony, assessed in the apical two-chamber view, was independently associated with PICM (p < 0.001). Thirty-seven (24%) leads were implanted anterior septal, 11 (7.2%) posterior septal, 74 (48.4%) apical, and 31 (20.3%) free wall. Left ventricular anterior-inferior dyssynchrony was significantly different between the four pacing lead locations (p < 0.01) with the highest rICA observed in the posterior septal group (1.30 ± 0.37). CONCLUSIONS: PICM is significantly associated increased contractile dyssynchrony assessed by rICA. This study suggests that especially left ventricular dyssynchrony in the anterior-inferior direction is associated with PICM, and pacing the right ventricular posterior septum resulted in the highest degree of anterior-inferior dyssynchrony. Quantification of left ventricular dyssynchrony by rICA provides important insights to the potential pathophysiology of PICM and the impact of right ventricular lead position.


Asunto(s)
Cardiomiopatías , Marcapaso Artificial , Disfunción Ventricular Izquierda , Humanos , Función Ventricular Izquierda/fisiología , Volumen Sistólico , Estudios Retrospectivos
4.
Eur Radiol ; 30(9): 5222, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32291500

RESUMEN

The original version of this article, published on 12 August 2019, unfortunately contained a mistake. The funding note was incorrect; the correct funding note is given below.

5.
Eur Radiol ; 30(1): 640-651, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31407030

RESUMEN

OBJECTIVES: The aim of this study was to investigate the prevalence and prognostic value of late gadolinium enhancement (LGE), as assessed by cardiovascular magnetic resonance (CMR) imaging, in patients with aortic stenosis. METHODS AND RESULTS: A systematic search of PubMed and EMBASE was performed, and observational cohort studies that analysed the prevalence of LGE and its relation to clinical outcomes in patients with aortic stenosis were included. Odds ratios were used to measure an effect of the presence of LGE on both all-cause and cardiovascular mortality. Nineteen studies were retrieved, accounting for 2032 patients (mean age 69.8 years, mean follow-up 2.8 years). We found that LGE is highly prevalent in aortic stenosis, affecting half of all patients (49.6%), with a non-infarct pattern being the most frequent type (63.6%). The estimated extent of focal fibrosis, expressed in % of LV mass, was equal to 3.83 (95% CI [2.14, 5.52], p < 0.0001). The meta-analysis showed that the presence of LGE was associated with increased all-cause (pooled OR [95% CI] = 3.26 [1.72, 6.18], p = 0.0003) and cardiovascular mortality (pooled OR [95% CI] = 2.89 [1.90, 4.38], p < 0.0001). CONCLUSIONS: LGE by CMR is highly prevalent in aortic stenosis patients and exhibits a substantial value in all-cause and cardiovascular mortality prediction. These results suggest a potential role of LGE in aortic stenosis patient risk stratification. KEY POINTS: • Up to the half of aortic stenosis patients are affected by myocardial focal fibrosis. • Sixty-four percent of focal fibrosis detected by LGE-CMR is non-infarct type. • The presence of focal fibrosis triples all-cause and cardiovascular mortality.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Medios de Contraste/farmacocinética , Gadolinio/farmacocinética , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Anciano , Aorta/diagnóstico por imagen , Estenosis de la Válvula Aórtica/patología , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Observacionales como Asunto , Prevalencia , Pronóstico
6.
BMC Cardiovasc Disord ; 20(1): 275, 2020 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-32513178

RESUMEN

BACKGROUND: Adverse cardiac remodeling with a myocardial fibrosis as a key pathophysiologic component may be associated to worse survival in aortic stenosis (AS) patients. Therefore, with the application of advanced cardiac imaging we aim to investigate left ventricular myocardial fibrosis in severe AS patients undergoing aortic valve replacement (AVR) and determine its impact with post-intervention clinical outcomes. METHODS: In a prospective, observational, cohort study patients with severe AS scheduled either for surgical or transcatheter AVR will be recruited from two tertiary heart centers in Denmark and Lithuania. All patients will receive standard of care in accordance with the current guidelines and will undergo additional imaging testing before and after AVR: echocardiography with deformation analysis and cardiovascular magnetic resonance (CMR) with T1 parametric mapping. Those undergoing surgical AVR will also have a myocardial biopsy sampled at the time of a surgery for histological validation. Patients will be recruited over a 2-year period and followed up to 2 years to ascertain clinical outcomes. Follow-up CMR will be performed 12 months following AVR, and echocardiography with deformation analysis will be performed 3, 12, and 24 months following AVR. The study primary outcome is a composite of all-cause mortality and major adverse cardiovascular events. DISCUSSION: Despite continuous effort of research community there is still a lack of early predictors of left ventricular decompensation in AS, which could improve patient risk stratification and guide the optimal timing for aortic valve intervention, before irreversible left ventricular damage occurs. Advanced cardiac imaging and CMR derived markers of diffuse myocardial fibrosis could be utilized for this purpose. FIB-AS study is intended to invasively and non-invasively assess diffuse myocardial fibrosis in AS patients and investigate its prognostic significance in post-interventional outcomes. The results of the study will expand the current knowledge of cardiac remodeling in AS and will bring additional data on myocardial fibrosis and its clinical implications following AVR. ETHICS/DISSEMINATION: The study has full ethical approval and is actively recruiting patients. The results will be disseminated through scientific journals and conference presentations. TRIAL REGISTRATION: ClinicalTrials.govNCT03585933. Registered on 02 July 2018.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía , Imagen por Resonancia Cinemagnética , Miocardio/patología , Función Ventricular Izquierda , Remodelación Ventricular , Estenosis de la Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Biopsia , Dinamarca , Femenino , Fibrosis , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Lituania , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Recuperación de la Función , Proyectos de Investigación , Factores de Tiempo , Resultado del Tratamiento
7.
Cardiovasc Ultrasound ; 17(1): 19, 2019 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-31601248

RESUMEN

BACKGROUND: Nearly one-third of heart failure (HF) patients do not respond to cardiac resynchronization therapy (CRT) despite having left bundle branch block (LBBB). The aim of the study was to investigate a novel method of quantifying left ventricular (LV) contractile asymmetry in HF. METHODS: Patients with HF and LBBB undergoing CRT (n = 89, 37.1% females, 68 ± 9 years, ischemic etiology in 61%, LV ejection fraction 27.1 ± 7.1%) were analyzed. LV longitudinal systolic strain rate values were extracted from curved anatomical M-mode plots of standard long-axis 2D-echocardiography images and cubic spline interpolation was used to generate a 3D-phantom. Index of contractile asymmetry (ICA) was calculated based on standard deviation of differences in strain rate of opposing walls. Average ICA was individually assessed pairwise in 12 opposing 30-degree LV sectors. Reduction in LV end-systolic volume (ESV) ≥15% after 6 months was considered as positive response to CRT. RESULTS: CRT response was found in 66 (74.2%) patients. Responders with both ischemic and non-ischemic cardiomyopathy had a higher and more extensive contractile asymmetry at baseline and achieved a greater ICA reduction after CRT than non-responders. Higher baseline ICA predicted higher degree and wider extent of ICA improvement. Also, both ICA at baseline and reduction of ICA correlated with the degree of ESV reduction after CRT. CONCLUSIONS: Quantification of asymmetrical LV activation in 3D by ICA provides valuable insights into LV contraction in case of LBBB and is a promising tool for improved patient selection for CRT.


Asunto(s)
Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca/métodos , Ecocardiografía Tridimensional/métodos , Insuficiencia Cardíaca/terapia , Contracción Miocárdica/fisiología , Selección de Paciente , Volumen Sistólico/fisiología , Anciano , Bloqueo de Rama/fisiopatología , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Estudios Prospectivos , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología
9.
J Nucl Cardiol ; 23(4): 670-9, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27094041

RESUMEN

BACKGROUND: Noninvasive estimation of myocardial external efficiency (MEE) requires measurements of left ventricular (LV) oxygen consumption with [(11)C]acetate PET in addition to LV stroke volume and mass with cardiovascular magnetic resonance (CMR). Measuring LV geometry directly from ECG-gated [(11)C]acetate PET might enable MEE evaluation from a single PET scan. Therefore, we sought to establish the accuracy of measuring LV volumes, mass, and MEE directly from ECG-gated [(11)C]acetate PET. METHODS: Thirty-five subjects with aortic valve stenosis underwent ECG-gated [(11)C]acetate PET and CMR. List mode PET data were rebinned into 16-bin ECG-gated uptake images before measuring LV volumes and mass using commercial software and compared to CMR. Dynamic datasets were used for calculation of mean LV oxygen consumption and MEE. RESULTS: LV mass, volumes, and ejection fraction measured by CMR and PET correlated strongly (r = 0.86-0.92, P < .001 for all), but were underestimated by PET (P < .001 for all except ESV P = .79). PET-based MEE, corrected for bias, correlated fairly with PET/CMR-based MEE (r = 0.60, P < .001, bias -3 ± 21%, P = .56). PET-based MEE bias was strongly associated with LV wall thickness. CONCLUSIONS: Although analysis-related improvements in accuracy are recommended, LV geometry estimated from ECG-gated [(11)C]acetate PET correlate excellently with CMR and can indeed be used to evaluate MEE.


Asunto(s)
Acetatos , Técnicas de Imagen Sincronizada Cardíacas/métodos , Consumo de Oxígeno , Tomografía de Emisión de Positrones/métodos , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Radioisótopos de Carbono , Técnicas de Imagen Cardíaca/métodos , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
Europace ; 18(4): 479-91, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26041870

RESUMEN

An increasing number of patients with implantable cardiac rhythm devices undergo radiotherapy (RT) for cancer and are thereby exposed to the risk of device failure. Current safety recommendations seem to have limitations by not accounting for the risk of pacemakers and implantable cardioverter defibrillators malfunctioning at low radiation doses. Besides scant knowledge about optimal safety measures, only little is known about the exact prevalence of patients with devices undergoing RT. In this review, we provide a short overview of the principles of RT and present the current evidence on the predictors and mechanisms of device malfunctions during RT. We also summarize practical recommendations from recent publications and from the industry. Strongly associated with beam energy of photon RT, device malfunctions occur at ∼3% of RT courses, posing a substantial issue in clinical practice. Malfunctions described in the literature typically consist of transient software disturbances and only seldom manifest as a permanent damage of the device. Through close cooperation between cardiologists and oncologists, a tailored individualized approach might be necessary in this patient group in waiting time for updated international guidelines in the field.


Asunto(s)
Estimulación Cardíaca Artificial , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Marcapaso Artificial , Falla de Prótesis , Radioterapia/efectos adversos , Estimulación Cardíaca Artificial/normas , Desfibriladores Implantables/normas , Cardioversión Eléctrica/normas , Seguridad de Equipos , Humanos , Marcapaso Artificial/normas , Seguridad del Paciente , Guías de Práctica Clínica como Asunto , Diseño de Prótesis , Radioterapia/normas , Dosificación Radioterapéutica , Medición de Riesgo , Factores de Riesgo
11.
Heart Vessels ; 31(1): 88-95, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25319673

RESUMEN

Acute coronary occlusion is effectively treated by primary percutaneous coronary intervention. However, myocardial ischemia-reperfusion injury is at the moment an unavoidable consequence of the procedure. Oxidative stress is central in the development of ischemia-reperfusion injury. Melatonin, an endogenous hormone, acts through antioxidant mechanisms and could potentially minimize the myocardial injury. The aim of the experimental study was to examine the cardioprotective effects of melatonin in a porcine closed-chest reperfused infarction model. A total of 20 landrace pigs were randomized to a dosage of 200 mg (0.4 mg/mL) melatonin or placebo (saline). The intervention was administered intracoronary and intravenous. Infarct size, area at risk and microvascular obstruction were determined ex vivo by cardiovascular magnetic resonance imaging. Myocardial salvage index was calculated. The plasma levels of high-sensitive troponin T were assessed repeatedly. The experimenters were blinded with regard to treatment regimen. Melatonin did not significantly increase myocardial salvage index compared with placebo [melatonin 21.8% (16.1; 24.8) vs. placebo 20.2% (16.9; 27.0), p = 1.00]. The extent of microvascular obstruction was similar between the groups [melatonin 3.8% (2.7; 7.1) vs. placebo 3.7% (1.3; 7.7), p = 0.96]. The area under the curve for high-sensitive troponin T release was insignificantly reduced by 32% in the melatonin group [AUC melatonin 12,343.9 (6,889.2; 20,147.4) ng h/L vs. AUC placebo 18,285.3 (5,180.4; 23,716.8) ng h/L, p = 0.82]. Combined intracoronary and intravenous treatment with melatonin did not reduce myocardial reperfusion injury. The lack of a positive effect could be due to an ineffective dose of melatonin, a type II error or the timing of administration.


Asunto(s)
Antioxidantes/administración & dosificación , Melatonina/administración & dosificación , Infarto del Miocardio/terapia , Daño por Reperfusión Miocárdica/tratamiento farmacológico , Estrés Oxidativo/efectos de los fármacos , Troponina T/sangre , Angioplastia Coronaria con Balón/efectos adversos , Animales , Modelos Animales de Enfermedad , Femenino , Imagen por Resonancia Magnética , Miocardio/patología , Distribución Aleatoria , Porcinos
12.
Pacing Clin Electrophysiol ; 38(3): 343-56, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25601489

RESUMEN

BACKGROUND: Pacemakers (PMs) and implantable cardioverter defibrillators (ICDs) may develop malfunction during external beam radiotherapy (RT). We aimed to describe clinical practice in PM/ICD patients undergoing RT and to assess the rate and predictors of device malfunctions. METHODS: We reviewed medical records of all PM/ICD patients undergoing RT at four centers in Western Denmark during 2003-2012. Logistic regression was applied to identify predictors of PM/ICD malfunctions. RESULTS: Five hundred sixty patients were included. The annual rate of RT courses in PM/ICD patients increased by 199% from 1.45 treatments per 100,000 person-years in 2003 to 4.33 in 2012. Safety measures included supplementary evaluations of PM/ICD (38.3%), reprogramming (1.5%), relocation of the device (3.5%), and application of a magnet to the ICD during RT (10.8%). At device evaluations after the RT (n = 453), malfunctions were detected in 10 (2.5%) PMs and four (6.8%) ICDs. Electrical resets constituted 11 (78.6%) of the malfunctions, and no failures were life-threatening or warranted PM/ICD removal. Factors associated with device malfunctions in logistic regression analysis were beam energy ≥15 MV (odds ratio [OR] 5.73; 95% confidence interval [CI], 1.58-20.76) and location of tumor below the diaphragm (OR 4.31; 95% CI, 1.42-13.12). However, the effect of tumor location declined (OR 2.27; 95% CI, 0.65-7.95) after adjustment for beam energy. CONCLUSIONS: Although the rate of RT in PM/ICD patients is increasing, the damaging effects of RT on the devices seem to be usually transient. Our data suggest that high beam energy plays the pivotal role in inducing impairments in these devices.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Análisis de Falla de Equipo , Neoplasias/radioterapia , Marcapaso Artificial/efectos adversos , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Dinamarca , Femenino , Humanos , Masculino , Riesgo , Medición de Riesgo
13.
Europace ; 16(4): 612-6, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23933852

RESUMEN

AIMS: Radiotherapy (RT) for malignancies can harm pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs). There is some evidence that, besides cumulative dose, the damaging radiation effects increase with beam energy. The aim of this study was to determine whether modern PMs and ICDs are more sensitive to high-energy than to low-energy photon beams. METHODS AND RESULTS: Two groups of unused PMs and explanted ICDs (five PMs and one ICD in each) were subjected to irradiations in a phantom with 6 and 18 megavolt (MV) photons, respectively. The devices were exposed to radiation at doses of 2 gray (Gy) daily to simulate two clinical scenarios with the PM/ICD in the RT field. A cumulative dose of 150 Gy was given to each device, corresponding to approximately twice the therapeutic dose. In the 6 MV group, one episode of PM malfunction was detected after reaching 150 Gy. In the 18 MV group, a total of 14 episodes of malfunction were detected starting at 30 Gy in all five PMs. No episodes appeared in the ICD, at the respective treatment groups. This corresponded to a hazard ratio of 9.11 [∼95% confidence interval (CI): 1.04-79.69] by Cox regression analysis between the two groups. In a repeated measures logistic regression model comparing the incidence rate of malfunctions, the odds ratio was 18.29 (∼95% CI: 1.52-219.41). CONCLUSION: Photon beam energy plays a considerable role in inducing implantable cardiac device malfunctions. Low-energy RT may be safer in PM/ICD patients despite relatively high radiation dose to the device.


Asunto(s)
Desfibriladores Implantables , Falla de Equipo , Marcapaso Artificial , Radioterapia de Alta Energía/efectos adversos , Diseño de Equipo , Análisis de Falla de Equipo , Modelos Logísticos , Ensayo de Materiales , Análisis Multivariante , Oportunidad Relativa , Fotones/efectos adversos , Modelos de Riesgos Proporcionales , Dosificación Radioterapéutica , Medición de Riesgo , Factores de Riesgo
14.
Artículo en Inglés | MEDLINE | ID: mdl-38664062

RESUMEN

BACKGROUND: Hypertrophic Cardiomyopathy (HCM) is characterized by unexplained left ventricle hypertrophy (LVH) ≥15 mm. The condition is often hereditary and family screening is recommended to reduce the risk of adverse disease complications and premature death among relatives. Correct diagnosis of index patients is important to ensure that only relatives at risk of disease development are invited for family screening. PURPOSE: To investigate if patients with ICD-10 codes for HCM (DI421) or hypertrophic obstructive cardiomyopathy (DI422) fulfilled recognised diagnostic criteria. METHODS: All patients with ICD-10 codes for HCM or HOCM at a Department of Cardiology were identified and had their diagnosis validated by a cardiac investigation or a review of their medical records and previous investigations. RESULTS: Two hundred and forty patients had ICD-10 codes for HCM/HOCM, of whom 202 (84%, 202/240) underwent re-examination, while 38 (16%, 38/240) had their hospital notes reviewed. Seventy-six patients (32%, n = 76/240) did not fulfil diagnostic criteria, of whom 39, (51%, n = 39/76) had normal (10 mm) or modest LV wall thickness (11-14 mm). The remaining 37 patients (49%, n = 37/76) had LVH ≥15 mm, which was well-explained by uncontrolled hypertension, (32%, n = 24/76), aortic valve stenosis (19%, n = 7/76) or wild-type amyloidosis (16%, 6/76). CONCLUSION: One-third of patients with ICD-10 codes for HCM or HOCM did not fulfil recognised diagnostic criteria. Incorrect diagnosis of HCM may cause unnecessary family investigations which may be associated with anxiety, and a waste of health care resources. This highlights the need for specialised cardiomyopathy services to ensure correct diagnosis and management of HCM.

15.
Pacing Clin Electrophysiol ; 36(12): 1558-63, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23952539

RESUMEN

INTRODUCTION: Although the effects of radiotherapy (RT) on implantable cardioverter defibrillators (ICDs) have been studied in vitro, and some information has been gathered from case reports and series, no in vivo experiments have previously been performed. METHODS: In vivo effects of photon RT applied directly to five modern ICD generators from different manufacturers implanted in pigs were studied. The devices were interrogated between and after increasing doses of ionizing radiation. Afterwards, the shock function was tested. RESULTS: All ICDs withstood fractionated irradiations with a cumulative dose of 18.5 gray (Gy) of 6 megavolt (MV) photons and 18.5 Gy of 18 MV photons and were still fully functional. Especially, no oversense was recorded. Induced ventricular fibrillation was detected and treated properly by shock therapy in all cases. However, one of the ICDs converted to back-up mode later the same night. CONCLUSION: The animal model is feasible for investigating RT effects on implanted cardiac devices. During irradiations with 37 Gy, one recoverable malfunction was present in the tested devices. Additional animal studies could provide supplementary evidence for treating ICD patients, including recommendations for reprogramming of the ICD during RT and avoidance of relocating the device.


Asunto(s)
Desfibriladores Implantables , Radioterapia de Alta Energía , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/prevención & control , Animales , Relación Dosis-Respuesta en la Radiación , Diseño de Equipo , Falla de Equipo , Análisis de Falla de Equipo , Dosis de Radiación , Porcinos , Porcinos Enanos
16.
Front Cardiovasc Med ; 10: 1087568, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36818351

RESUMEN

Aim: Current non-invasive electrocardiographic imaging (ECGi) methods are often based on complex body surface potential mapping, limiting the clinical applicability. The aim of this pilot study was to evaluate the ability of a novel non-invasive ECGi method, based on the standard 12-lead ECG, to localize initial site of ventricular activation in right ventricular (RV) paced patients. Validation of the method was performed by comparing the ECGi reconstructed earliest site of activation against the true RV pacing site determined from cardiac computed tomography (CT). Methods: This was a retrospective study using data from 34 patients, previously implanted with a dual chamber pacemaker due to advanced atrioventricular block. True RV lead position was determined from analysis of a post-implant cardiac CT scan. The ECGi method was based on an inverse-ECG algorithm applying electrophysiological rules. The algorithm integrated information from an RV paced 12-lead ECG together with a CT-derived patient-specific heart-thorax geometric model to reconstruct a 3D electrical ventricular activation map. Results: The mean geodesic localization error (LE) between the ECGi reconstructed initial site of activation and the RV lead insertion site determined from CT was 13.9 ± 5.6 mm. The mean RV endocardial surface area was 146.0 ± 30.0 cm2 and the mean circular LE area was 7.0 ± 5.2 cm2 resulting in a relative LE of 5.0 ± 4.0%. Conclusion: We demonstrated a novel non-invasive ECGi method, based on the 12-lead ECG, that accurately localized the RV pacing site in relation to the ventricular anatomy.

17.
Eur Heart J Imaging Methods Pract ; 1(2): qyad045, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39045065

RESUMEN

Aims: Currently, electrical rather than mechanical parameters of delayed left ventricular (LV) activation are used for patient selection for cardiac resynchronization therapy (CRT). However, despite adhering to current guideline-based criteria, about one-third of heart failure (HF) patients fail to derive benefit from CRT. This study sought to investigate the prognostic survival significance of a recently introduced index of contractile asymmetry (ICA) based on the deformation of entire opposing LV walls in the context of selecting patients with HF and left bundle branch abnormality (LBBB) for CRT. Methods and results: We analysed 367 patients with HF and LBBB undergoing CRT (31.6% females, 69 ± 9 years, ischaemic aetiology in 50.7%, LV ejection fraction 27 ± 6%). ICA was calculated using LV strain rate values from curved anatomical M-mode plots of apical 2D echocardiography images. The predictive value of ICA was assessed using Kaplan-Meier analysis and Cox proportional hazards models. During a median follow-up time of 5.54 years, death or cardiac transplantation occurred in 105 (28.6%) cases. Higher baseline ICA values in all apical views, particularly in the two-chamber view (ICA-2ch), were associated with increased event-free survival, and the unadjusted hazard ratio was 0.28 (95% confidence interval 0.18-0.46). Higher ICA-2ch (>0.319 s-1) consistently predicted survival across clinical subgroups and remained significant after covariate adjustment, while the event rate sharply increased in low ICA-2ch cases. Additionally, including ICA-2ch improved the predictive value of the multivariate risk model containing the typical LBBB pattern. Conclusion: Pre-implant ICA suggests a quantitative prognostic threshold for both long-term survival and adverse outcomes following CRT implantation.

18.
Atheroscler Plus ; 50: 65-71, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36643796

RESUMEN

Background and aims: Limited knowledge exists regarding the association between coronary artery calcium (CAC) deposition in patients with clinical familial hypercholesterolemia (FH) and FH subtypes such as polygenic causes. We studied CAC score in patients with clinical FH and subtypes including polygenic causes of FH compared to healthy controls. Methods: In a case-control study, we identified potential clinical FH cases registered with an LDL-C >6.7 mmol/l within a nationwide clinical laboratory database on the Faroe Islands and invited them for diagnostic evaluation according to clinical FH scoring systems. Controls were identified in the background population. All subjects were aged 18-75 years and without a history of cardiovascular disease. FH mutation testing and genotypes of twelve LDL-C associated single nucleotide polymorphisms were determined using conventional methods in selected individuals. CAC scores were assessed by cardiac CT. Odds ratios obtained using multivariate logistic regression were used as measures of association. Results: A total of 120 clinical FH patients and 117 age- and sex-matched controls were recruited. We found a very low frequency of monogenic FH (3%), but a high level of polygenic FH (60%) in those genetically tested (54%). There was a statistically significant association between the CAC score and a diagnosis of clinical FH with the highest observed odds ratio of 5.59 (95% CI 1.65; 18.94, p = 0.006) in those with a CAC score ≥300 compared to those with a CAC of zero. In supplemental analyses, there was a strong association between CAC scores and clinical FH of a polygenic cause. Conclusion: We found a statistically significant association between CAC levels and clinical FH with the highest observed risk estimates among clinical FH cases of a presumed polygenic cause.

19.
Int J Cardiovasc Imaging ; 38(10): 2177-2190, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37726455

RESUMEN

Assessment of the left ventricular (LV) function by three-dimensional echocardiography (3DE) is potentially superior to 2D echo echocardiography (2DE) for LV performance assessment. However, intra- and interobserver variation needs further investigation. We examined the intra- and interobserver variability between 2 and 3DE in a general population. In total, 150 participants from the Copenhagen City Heart Study were randomly chosen. Two observers assessed left ventricular ejection fraction (LVEF), end-diastolic (EDV) and end-systolic volumes (ESV) by 2DE and 3DE. Inter-, intraobserver and intermodality variabilities are presented as means of difference (MD), limits of agreement (LoA), coefficient of correlation (r), intraclass correlation coefficients (ICC). The lowest MD and LoA and highest r- and ICC-values was generally seen among the 3D acquisitions, with the 3D EDV interobserver as the best performing estimate (r = 0.95, ICC = 0.94). The largest MD, LoA and lowest r- and ICC-values was found in the interobserver 2D LVEF (r = 0.76, ICC = 0.63. For the intraobserver analysis, there were statistically significant differences between observations for all but 3DE EDV (p = 0.06). For interobserver analysis, there were statistically significant differences between observers for all estimates but 2DE EDV (p = 0.11), 3D ejection fraction (p = 0.9), 3DE EDV (p = 0.11) and 3D ESV (p = 0.15). Three-dimensional echocardiography is more robust and reproducible than 2DE and should be preferred for assessment of LV function.


Asunto(s)
Ecocardiografía Tridimensional , Función Ventricular Izquierda , Humanos , Variaciones Dependientes del Observador , Volumen Sistólico , Valor Predictivo de las Pruebas , Ecocardiografía
20.
J Clin Med ; 11(23)2022 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-36498801

RESUMEN

Prospective studies applying fluoroscopy for assessment of right ventricular (RV) lead position have failed to show clear benefits from RV septal pacing. We investigated the impact of different RV lead positions verified by computed tomography (CT) on the risk of pacing-induced cardiomyopathy (PICM). We retrospectively included 153 patients who underwent routine fluoroscopy-guided pacemaker implantation between March 2012 and May 2020. All patients had normal pre-implant left ventricular ejection fraction (LVEF). Patients attended a follow-up visit including contrast-enhanced cardiac CT and transthoracic echocardiography. Patients were classified as septal or non-septal based on CT analysis. The primary endpoint was PICM (LVEF < 50% with ≥10% decrease after implantation). Based on CT, 48 (31.4%) leads were septal and 105 (68.6%) were non-septal. Over a median follow-up of 3.1 years, 16 patients (33.3%) in the septal group developed PICM compared to 31 (29.5%) in the non-septal group (p = 0.6). Overall, 13.1% deteriorated to LVEF ≤ 40%, 5.9% were upgraded to cardiac resynchronization therapy device, and 14.4% developed new-onset atrial fibrillation, with no significant differences between the groups. This study demonstrated a high risk of PICM despite normal pre-implant left ventricular systolic function with no significant difference between CT-verified RV septal or non-septal lead position.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA