Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Int J Biol Macromol ; 270(Pt 1): 132381, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38754664

RESUMEN

Florfenicol (FF), with its broad-spectrum antibacterial activity, is frequently abused in the livestock and poultry industries and has aroused the growing public concern. Owing to structural similarities and varying maximum residue limits between florfenicol and other chloramphenicol (CAP)-type antibiotics, including thiamphenicol (TAP) and chloramphenicol (CAP), there is an urgent need for a rapid and effective immunoassay method to distinguish them, in order to minimize the risk of false positives. Fortunately, a highly specific monoclonal antibody (mAb), named as SF11, has been developed using hybridoma technology. Molecular simulations have revealed that the mAb SF11's specificity in recognizing florfenicol stems from the π-π stacking interaction between florfenicol and the mAb SF11 binding pocket. Using this highly specific mAb, a sensitive time-resolved fluorescence immunochromatographic assay (TRFICA) strip for rapid florfenicol detection has been developed. Under optimal conditions, this TRFICA demonstrated good analytical performance for the detection of florfenicol in milk and eggs samples, with the half-maximal inhibition concentration (IC50) values of 1.89 and 2.86 ng mL-1, the limit of detection (LOD) of 0.23 and 0.48 ng mL-1, the cut-off values of 62.50 and 31.25 ng mL-1, and the testing time of approximately thirteen minutes. Spiked recoveries in the milk and eggs samples ranged from 104.7 % to 112.3 % and 95.3 % to 116.4 %, respectively, with no obvious cross-reactions with the other analogues observed. The TRFICA results correlated well with those of high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) for real samples, indicating that the developed TRFICA method was sensitive, accurate and adapted for the rapid determination of florfenicol in milk and egg samples.


Asunto(s)
Anticuerpos Monoclonales , Huevos , Leche , Tianfenicol , Tianfenicol/análogos & derivados , Tianfenicol/análisis , Leche/química , Animales , Huevos/análisis , Anticuerpos Monoclonales/química , Residuos de Medicamentos/análisis , Inmunoensayo/métodos , Cromatografía de Afinidad/métodos , Antibacterianos/análisis , Antibacterianos/química , Contaminación de Alimentos/análisis
2.
Microbiol Spectr ; : e0080924, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39145655

RESUMEN

African swine fever (ASF), caused by ASF virus (ASFV), is a highly infectious and severe hemorrhagic disease of pigs that causes major economic losses. Currently, no commercial vaccine is available and prevention and control of ASF relies mainly on early diagnosis. Here, a novel automated double antigen sandwich chemiluminescent immunoassay (DAgS-aCLIA) was developed to detect antibodies against ASFV p72 (p72-Ab). For this purpose, recombinant p72 trimer was produced, coupled to magnetic particles as carriers and labeled with acridinium ester as a signal trace. Finally, p72-Ab can be sensitively and rapidly measured on an automated chemiluminescent instrument. For quantitative analysis, a calibration curve was established with a laudable linearity range of 0.21 to 212.0 ng/mL (R2 = 0.9910) and a lower detection limit of 0.15 ng/mL. For qualitative analysis, a cut-off value was set at 1.50 ng/mL with a diagnostic sensitivity of 100.00% and specificity of 98.33%. Furthermore, antibody response to an ASF gene-deleted vaccine candidate can be accurately quantified using this DAgS-aCLIA, as evidenced by early seroconversion as early as 7 days post-immunization and high antibody levels. Compared with available enzyme-linked immunosorbent assays, this DAgS-aCLIA demonstrated a wider linearity range of 4 to 16-fold, and excellent analytical sensitivity and agreement of over 95.60%. In conclusion, our proposed DAgS-aCLIA would be an effective tool to support ASF epidemiological surveillance.IMPORTANCEAfrican swine fever virus (ASFV) is highly contagious in wild boar and domestic pigs. There is currently no vaccine available for ASF, so serological testing is an important diagnostic tool. Traditional enzyme-linked immunosorbent assays provide only qualitative results and are time and resource consuming. This study will develop an automated chemiluminescent immunoassay (CLIA) that can quantitatively and qualitatively detect antibodies to ASFV p72, greatly reducing detection time and labour-intensive operation, and improving detection sensitivity and linearity range. This novel CLIA would serve as a reliable and convenient tool for ASF pandemic surveillance and vaccine development.

3.
Food Chem ; 450: 139372, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-38640545

RESUMEN

Based on the size and surface properties of dimethomorph and flumorph, we used a computer simulation-assisted size exclusion hapten design strategy to develop group-specific monoclonal antibodies that can simultaneously recognize dimethomorph and flumorph. For this, we performed quantitative and visual semi-quantitative time-resolved fluorescence immunochromatography (TRFICA) to simultaneously detect dimethomorph and flumorph in potatoes and apples. In potato samples, the visual limit of detection (vLOD) for dimethomorph and flumorph was 4 ng/mL and 8 ng/mL, respectively, whereas the quantitative limit of detection (qLOD) for dimethomorph and flumorph was 0.26 and 0.33 ng/mL, respectively. The vLOD of dimethomorph and flumorph in apple samples was 8 ng/mL, whereas the qLOD of dimethomorph and flumorph was 0.17 and 0.38 ng/mL, respectively. The average recovery of potato and apple samples ranged from 77.5% to 121.7%, which indicated that the method can be used to rapidly detect dimethomorph and flumorph in food samples.


Asunto(s)
Cromatografía de Afinidad , Contaminación de Alimentos , Haptenos , Malus , Solanum tuberosum , Solanum tuberosum/química , Haptenos/química , Malus/química , Contaminación de Alimentos/análisis , Cromatografía de Afinidad/métodos , Cromatografía de Afinidad/instrumentación , Anticuerpos Monoclonales/química , Límite de Detección , Fungicidas Industriales/análisis
4.
J Agric Food Chem ; 72(12): 6772-6780, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38478886

RESUMEN

Trimethoprim (TMP), functioning as a synergistic antibacterial agent, is utilized in diagnosing and treating diseases affecting livestock and poultry. Human consumption of the medication indirectly may lead to its drug accumulation in the body and increase drug resistance due to its prolonged metabolic duration in livestock and poultry, presenting significant health hazards. Most reported immunoassay techniques, such as ELISA and immunochromatographic assay (ICA), find it challenging to achieve the dual advantages of high sensitivity, simplicity of operation, and a wide detection range. Consequently, an open droplet microchannel-based magnetosensor for immunofluorometric assay (OMM-IFA) of trimethoprim was created, featuring a gel imager to provide a signal output derived from the highly specific antibody (Ab) targeting trimethoprim. The method exhibited high sensitivity in chicken and pork samples, with LODs of 0.300 and 0.017 ng/mL, respectively, and a wide linear range, covering trimethoprim's total maximum residue limits (MRLs). Additionally, the spiked recoveries in chicken and pork specimens varied between 81.6% and 107.9%, maintaining an acceptable variation coefficient below 15%, aligning well with the findings from the ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) technique. The developed method achieved a much wider linear range of about 5 orders of magnitude of 10-2-103 levels with grayscale signals as the output signal, which exhibited high sensitivity, excellent applicability and simple operability based on magnetic automation.


Asunto(s)
Carne de Cerdo , Carne Roja , Animales , Humanos , Porcinos , Trimetoprim , Cromatografía Liquida , Pollos , Espectrometría de Masas en Tándem/métodos , Aves de Corral , Fluoroinmunoensayo , Cromatografía Líquida de Alta Presión/métodos
5.
J Environ Monit ; 13(11): 3040-8, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21915424

RESUMEN

The development of easy-to-use and rapid-monitoring immunoassay methods for organic environmental pollutants in a class-selective manner is a topic of considerable environmental interest. In this work, a heterologous competitive indirect enzyme-linked immunosorbent assay (ciELISA) based on a monoclonal antibody (MAb) with broad-specificity for organophosphorus pesticides (OPs) was applied to the detection of O,O-diethyl and O,O-dimethyl OPs in water samples. The ciELISA conditions were carefully optimized to obtain a three to five-fold improvement of sensitivity for most OPs, and thirteen OPs were determined at concentrations ranging from 0.017 to 30 ng mL(-1). The determination of spiked environmental water samples showed average recoveries from 81.5% to 115.1%, with the coefficient of variation (CV) ranging from 6.1% to 20.9%, which showed satisfactory reproducibility of the developed ciELISA. To overcome the negative aspect of broad-specificity immunoassays not providing qualitative and quantitative analysis of individual OPs in blind samples, we used "percent inhibition rate" to make the developed ciELISA a semi-quantitative method, which allows the monitoring of positive samples from hundreds of negative samples. The determination of OPs in blind water samples by the developed ELISA with confirmation by HPLC-MS/MS analysis demonstrated that the assay is ideally suited as a screening method for OP residues prior to chromatographic analysis.


Asunto(s)
Anticuerpos Monoclonales , Monitoreo del Ambiente/métodos , Ensayo de Inmunoadsorción Enzimática/métodos , Compuestos Organofosforados/análisis , Plaguicidas/análisis , Contaminantes Químicos del Agua/análisis , Cromatografía Líquida de Alta Presión , Límite de Detección , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Masas en Tándem
6.
J Agric Food Chem ; 60(9): 2069-75, 2012 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-22329773

RESUMEN

Solid-phase extraction (SPE) and direct competitive chemiluminescence enzyme immunoassay (dcCL-EIA) were combined for the detection of organophosphorus pesticides (OPs) in environmental water samples. dcCL-EIA based on horseradish peroxidase labeled with a broad-specificity monoclonal antibody against OPs was developed, and the effects of several physicochemical parameters on dcCL-EIA performance were studied. SPE was used for the pretreatment of water samples to remove interfering substances and to concentrate the OP analytes. The coupling of SPE and dcCL-EIA can detect seven OPs (parathion, coumaphos, phoxim, quinalphos, triazophos, dichlofenthion, and azinphos-ethyl) with the limit of quantitation below 0.1 ng/mL. The recoveries of OPs from spiked water samples ranged from 62.5% to 131.7% by SPE-dcCL-EIA and 69.5% to 112.3% by SPE-HPLC-MS/MS. The screening of OP residues in real-world environmental water samples by the developed SPE-dcCL-EIA and their confirmatory analysis using SPE-HPLC-MS/MS demonstrated that the assay is ideally suited as a monitoring method for OP residues prior to chromatographic analysis.


Asunto(s)
Técnicas para Inmunoenzimas/métodos , Mediciones Luminiscentes/métodos , Compuestos Organofosforados/análisis , Plaguicidas/análisis , Extracción en Fase Sólida/métodos , Contaminantes Químicos del Agua/análisis , Animales , Anticuerpos Monoclonales/inmunología , Especificidad de Anticuerpos , Cromatografía Líquida de Alta Presión , Femenino , Ratones , Ratones Endogámicos BALB C , Espectrometría de Masas en Tándem , Agua/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA