Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Anal Bioanal Chem ; 415(17): 3385-3398, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37140675

RESUMEN

Nanozyme, with enzyme-mimicking activity and excellent stability, has attracted extensive attention. However, some inherent disadvantages, including poor dispersion, low selectivity, and insufficient peroxidase-like activity, still limit its further development. Therefore, an innovative bioconjugation of a nanozyme and natural enzyme was conducted. In the presence of graphene oxide (GO), histidine magnetic nanoparticles (H-Fe3O4) were first synthesized by a solvothermal method. The GO-supported H-Fe3O4 (GO@H-Fe3O4) exhibited superior dispersity and biocompatibility because GO was the carrier and possessed outstanding peroxidase-like activity because of the introduction of histidine. Furthermore, the mechanism of the peroxidase-like activity of GO@H-Fe3O4 was the generation of •OH. Uric acid oxidase (UAO) was selected as the model natural enzyme and covalently linked to GO@H-Fe3O4 with hydrophilic poly(ethylene glycol) as a linker. UAO could specifically catalyze the oxidation of uric acid (UA) to generate H2O2, and subsequently, the newly produced H2O2 oxidized the colorless 3,3',5,5'-tetramethylbenzidine (TMB) to blue ox-TMB under the catalysis of GO@H-Fe3O4. Based on the above cascade reaction, the GO@H-Fe3O4-linked UAO (GHFU) and GO@H-Fe3O4-linked ChOx (GHFC) were used for the detection of UA in serum samples and cholesterol (CS) in milk, respectively. The method based on GHFU exhibited a wide detection range (5-800 µM) and a low detection limit (1.5 µM) for UA, and the method based on GHFC exhibited a wide detection range (4-400 µM) and a low detection limit (1.13 µM) for CS. These results demonstrated that the proposed strategy had great potential in the field of clinical detection and food safety.


Asunto(s)
Peróxido de Hidrógeno , Ácido Úrico , Histidina , Peroxidasa/metabolismo , Colorimetría
2.
Asian J Androl ; 11(2): 209-14, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19122678

RESUMEN

We conducted a prospective study of erectile dysfunction (ED) after urethral reconstructive surgery, using the 5-item International Index of Erectile Function (IIEF-5), the Sexual Life Quality Questionnaire (SLQQ) and the Quality of Life Questionnaire (QoLQ). Between January 2003 and July 2007, 125 male patients with urethral strictures underwent urethroplasty, and pre- and post-surgery erectile function was assessed using these three questionnaires. A formula to predict the probability of ED after urethroplasty was derived. At 3 months post-operatively, there was a significant decrease in IIEF-5 (16.57 +/- 7.98) and SLQQ scores (28.71 +/- 14.84) compared with pre-operative scores (P < 0.05). However, the IIEF-5 scores rebounded at 6 months post-operatively (17.22 +/- 8.41). Logistical regression analysis showed that the location of the urethral stricture, the recurrence of strictures and the choice of surgical technique were predictive of the post-operative occurrence of ED. This study identified the clinical risk factors for ED after urethroplasty. Posterior urethral stricture and end-to-end anastomosis were found to have a strong relationship with erectile function. The logistical model derived in this study may be applied to clinical decision algorithms for patients with urethral strictures.


Asunto(s)
Disfunción Eréctil/etiología , Procedimientos de Cirugía Plástica/efectos adversos , Complicaciones Posoperatorias/etiología , Uretra/cirugía , Adulto , Disfunción Eréctil/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/fisiopatología , Estudios Prospectivos , Calidad de Vida , Autoexamen , Encuestas y Cuestionarios , Uretra/patología , Estrechez Uretral/patología , Estrechez Uretral/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA