Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Small ; : e2403385, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-39031720

RESUMEN

Healthcare has undergone a revolutionary shift with the advent of smart technologies, and smart toilets (STs) are among the innovative inventions offering non-invasive continuous health monitoring. The present technical challenges toward this development include limited sensitivity of integrated sensors, poor stability, slow response and the requirement external energy supply alongside manual sample collection. In this article, triboelectric nanosensor array (TENSA) is introduced featuring electrodes crafted from laser-induced 3D graphene with functional polymers like polystyrene, polyimide, and polycaprolactone for real-time urine analysis while generating 50 volts output via urine droplet-based triboelectrification. Though modulating interfacial double-layer capacitance, these sensors exhibit exceptional sensitivity and selectivity in detecting a broad spectrum of urinary biomarkers, including ions, glucose, and urea with a classification precision of 95% and concentration identification accuracy of up to 0.97 (R2), supported by artificial neural networks. Upon exposure to urine samples containing elevated levels of Na+, K+, and NH4 +, a notable decrease (ranging from 32% to 68%) is observed in output voltages. Conversely, urea induces an increase up to 13%. Experimental validation confirms the stability, robustness, reliability, and reproducibility of TENSA, representing a significant advancement in healthcare technology, offering the potential for improved disease management and prevention strategies.

2.
BMC Cancer ; 24(1): 1064, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39198775

RESUMEN

PURPOSE: Recent studies have increasingly linked Ephrin receptor B2 (EPHB2) to cancer progression. However, comprehensive investigations into the immunological roles and prognostic significance of EPHB2 across various cancers remain lacking. METHODS: We employed various databases and bioinformatics tools to investigate the impact of EPHB2 on prognosis, immune infiltration, genome instability, and response to immunotherapy. Validation of the correlation between EPHB2 expression and M2 macrophages included analyses using bulk and single-cell transcriptomic datasets, spatial transcriptomics, and multi-fluorescence staining. Moreover, we performed cMap web tool to screen for EPHB2-targeted compounds and assessed their potential through molecular docking and dynamics simulations. Additionally, in vitro validation using lung adenocarcinoma (LUAD) cell lines was conducted to confirm the bioinformatics predictions about EPHB2. RESULTS: EPHB2 dysregulation was observed across multiple cancer types, where it demonstrated significant diagnostic and prognostic value. Gene Set Enrichment Analysis (GSEA) indicated that EPHB2 is involved in enhancing cellular proliferation, invasiveness of cancer cells, and modulation of the anti-cancer immune response. Furthermore, it is emerged as a pan-cancer marker for M2 macrophage infiltration, supported by integrated analyses of transcriptomics and multiple fluorescence staining. In LUAD cells, knockdown of EPHB2 expression led to a decrease in both cell proliferation and migratory activity. CONCLUSION: EPHB2 expression may serve as a pivotal indicator of M2 macrophage infiltration, offering vital insights into tumor dynamics and progression across various cancers, including lung adenocarcinoma, highlighting its significant prognostic and therapeutic potential for further exploration.


Asunto(s)
Biomarcadores de Tumor , Inmunoterapia , Receptor EphB2 , Humanos , Receptor EphB2/genética , Receptor EphB2/metabolismo , Pronóstico , Biomarcadores de Tumor/genética , Biomarcadores de Tumor/metabolismo , Inmunoterapia/métodos , Línea Celular Tumoral , Biología Computacional/métodos , Neoplasias/genética , Neoplasias/inmunología , Neoplasias/terapia , Regulación Neoplásica de la Expresión Génica , Proliferación Celular , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/inmunología , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/metabolismo , Perfilación de la Expresión Génica , Adenocarcinoma del Pulmón/genética , Adenocarcinoma del Pulmón/inmunología , Adenocarcinoma del Pulmón/patología , Adenocarcinoma del Pulmón/metabolismo , Adenocarcinoma del Pulmón/tratamiento farmacológico , Adenocarcinoma del Pulmón/terapia , Movimiento Celular , Simulación del Acoplamiento Molecular
3.
BMC Cancer ; 24(1): 1138, 2024 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-39267056

RESUMEN

PURPOSE: Lung adenocarcinoma (LUAD) significantly contributes to cancer-related mortality worldwide. The heterogeneity of the tumor immune microenvironment in LUAD results in varied prognoses and responses to immunotherapy among patients. Consequently, a clinical stratification algorithm is necessary and inevitable to effectively differentiate molecular features and tumor microenvironments, facilitating personalized treatment approaches. METHODS: We constructed a comprehensive single-cell transcriptional atlas using single-cell RNA sequencing data to reveal the cellular diversity of malignant epithelial cells of LUAD and identified a novel signature through a computational framework coupled with 10 machine learning algorithms. Our study further investigates the immunological characteristics and therapeutic responses associated with this prognostic signature and validates the predictive efficacy of the model across multiple independent cohorts. RESULTS: We developed a six-gene prognostic model (MYO1E, FEN1, NMI, ZNF506, ALDOA, and MLLT6) using the TCGA-LUAD dataset, categorizing patients into high- and low-risk groups. This model demonstrates robust performance in predicting survival across various LUAD cohorts. We observed distinct molecular patterns and biological processes in different risk groups. Additionally, analysis of two immunotherapy cohorts (N = 317) showed that patients with a high-risk signature responded more favorably to immunotherapy compared to those in the low-risk group. Experimental validation further confirmed that MYO1E enhances the proliferation and migration of LUAD cells. CONCLUSION: We have identified malignant cell-associated ligand-receptor subtypes in LUAD cells and developed a robust prognostic signature by thoroughly analyzing genomic, transcriptomic, and immunologic data. This study presents a novel method to assess the prognosis of patients with LUAD and provides insights into developing more effective immunotherapies.


Asunto(s)
Adenocarcinoma del Pulmón , Neoplasias Pulmonares , Microambiente Tumoral , Humanos , Adenocarcinoma del Pulmón/genética , Adenocarcinoma del Pulmón/patología , Adenocarcinoma del Pulmón/mortalidad , Adenocarcinoma del Pulmón/inmunología , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/mortalidad , Pronóstico , Microambiente Tumoral/genética , Microambiente Tumoral/inmunología , Biomarcadores de Tumor/genética , Inmunoterapia , Regulación Neoplásica de la Expresión Génica , Perfilación de la Expresión Génica , Femenino , Análisis de la Célula Individual/métodos , Masculino , Transcriptoma , Aprendizaje Automático , Multiómica
4.
Sens Actuators B Chem ; 398: 134788, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38164440

RESUMEN

Online monitoring of prognostic biomarkers is critically important when diagnosing disorders and assessing individuals' health, especially for chronic and infectious diseases. Despite this, current diagnosis techniques are time-consuming, labor-intensive, and performed offline. In this context, developing wearable devices for continuous measurements of multiple biomarkers from body fluids has considerable advantages including availability, rapidity, convenience, and minimal invasiveness over the conventional painful and time-consuming tools. However, there is still a significant challenge in powering these devices over an extended period, especially for applications that require continuous and long-term health monitoring. Herein, a new freestanding, wearable, multifunctional microneedle-based extended gate field effect transistor biosensor is fabricated for online detection of multiple biomarkers from the interstitial fluid including sodium, calcium, potassium, and pH along with excellent electrical response, reversibility, and precision. In addition, a hybrid powering system of triboelectric nanogenerator and solar cell was developed for creating a freestanding, closed-loop platform for continuous charging of the device's battery and integrated with an Internet of Things technology to broadcast the measurements online, suggesting a stand-alone, stable multifunctional tool which paves the way for advanced practical personalized health monitoring and diagnosis.

5.
Small ; 19(51): e2207539, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36950771

RESUMEN

The rapid development of wearable biosensing calls for next-generation devices that allow continuous, real-time, and painless monitoring of health status along with responsive medical treatment. Microneedles have exhibited great potential for the direct access of dermal interstitial fluid (ISF) in a minimally invasive manner. Recent studies of microneedle-based devices have evolved from conventional off-line detection to multiplexed, wireless, and integrated sensing. In this review, the classification and fabrication techniques of microneedles are first introduced, and then the representative examples of microneedles for transdermal monitoring with different sensing modalities are summarized. State-of-the-art advances in therapeutic and closed-loop systems are presented to formulate guidelines for the development of next-generation microneedle-based healthcare platforms. The potential challenges and prospects are discussed to pave a new avenue toward pragmatic applications in the real world.


Asunto(s)
Técnicas Biosensibles , Dispositivos Electrónicos Vestibles , Técnicas Biosensibles/métodos , Agujas , Administración Cutánea , Atención a la Salud
6.
Sensors (Basel) ; 23(2)2023 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-36679373

RESUMEN

Triboelectric nanogenerators (TENGs) stand out as an attractive form of technology for the efficient harvest of mechanical energy and the powering of wearable devices due to their light weight, simplicity, high power density, and efficient vibration energy scavenging capabilities. However, the requirement for micro/nanostructures and/or complex and expensive instruments hinders their cheap mass production, thus limiting their practical applications. By using a simple, cost-effective, fast spray-coating process, we develop high-performance UV-curable triboelectric coatings for large-scale energy harvesting. The effect of different formulations and coating compositions on the triboelectric output is investigated to design triboelectric coatings with high output performance. The TENG based on a hybrid coating exhibits high output performance of 54.5 µA current, 1228.9 V voltage, 163.6 nC transferred charge and 3.51 mW output power. Moreover, the hybrid coatings show good long-term output stability. All the results indicate that the designed triboelectric coatings show great potential for large-scale energy harvesting with the advantages of cost-effectiveness, fast fabrication, easy mass production and long-term stability.


Asunto(s)
Nanoestructuras , Compuestos Orgánicos , Fenómenos Físicos , Tecnología , Vibración
7.
Analyst ; 147(20): 4413-4416, 2022 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-36148514

RESUMEN

Herein, we report a portable point-of-care testing (POCT) device based on an aptamer-engineered extended-gate field-effect transistor (EG-FET) for therapeutic monitoring of the drug methotrexate. This method was shown to be highly sensitive, efficient, and convenient to use, features contributing to its realizing a clinical detection of drugs in blood.


Asunto(s)
Técnicas Biosensibles , Técnicas Biosensibles/métodos , Monitoreo de Drogas , Metotrexato , Oligonucleótidos , Sistemas de Atención de Punto
8.
Small ; 16(24): e2001363, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32390318

RESUMEN

Achieving highly accurate responses to external stimuli during human motion is a considerable challenge for wearable devices. The present study leverages the intrinsically high surface-to-volume ratio as well as the mechanical robustness of nanostructures for obtaining highly-sensitive detection of motion. To do so, highly-aligned nanowires covering a large area were prepared by capillarity-based mechanism. The nanowires exhibit a strain sensor with excellent gauge factor (≈35.8), capable of high responses to various subtle external stimuli (≤200 µm deformation). The wearable strain sensor exhibits also a rapid response rate (≈230 ms), mechanical stability (1000 cycles) and reproducibility, low hysteresis (<8.1%), and low power consumption (<35 µW). Moreover, it achieves a gauge factor almost five times that of microwire-based sensors. The nanowire-based strain sensor can be used to monitor and discriminate subtle movements of fingers, wrist, and throat swallowing accurately, enabling such movements to be integrated further into a miniaturized analyzer to create a wearable motion monitoring system for mobile healthcare.


Asunto(s)
Nanocables , Dispositivos Electrónicos Vestibles , Humanos , Monitoreo Fisiológico , Movimiento (Física) , Reproducibilidad de los Resultados
9.
Small ; 12(10): 1315-21, 2016 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-26763138

RESUMEN

Aligning PbZr(0.52)Ti(0.48)O3 (PZT) nanowires in polydimethylsiloxane introduces dielectrophoresis, improving the electromechanical properties of nanogenerators, and the light transmittance of composite films. A novel transparent and antipeep piezoelectric nanogenerator is developed that can be used for harvesting the energy from the light tapping of a finger on a cell phone, with an output current of 0.8 nA.

10.
Environ Technol ; 36(13-16): 1759-70, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25608464

RESUMEN

High phosphate content in wastewater is currently a major issue faced by the North American greenhouse industry. Phosphate-sorbing material filters could provide a means of removing phosphate from wastewater prior to discharge to the environment, but the characterization of economically viable materials and specific recommendations for greenhouse wastewater are not available. Batch and column experiments were used to examine the capacity of two calcium-based waste materials, basic oxygen furnace slag and a concrete waste material, to remove phosphate from greenhouse nutrient solution at varied operating conditions. Material columns operating at a hydraulic retention time (HRT) of 3 h consistently removed >99% of influent phosphate at a concentration of 60 mg/L over repeated applications and demonstrated high phosphate retention capacity (PRC) of 8.8 and 5.1 g P/kg for slag and concrete waste, respectively. Both materials also provided some removal of the micronutrients Fe, Mn and Zn. Increasing HRT to 24 h increased P retention capacity of slag to >10.5 g P/kg but did not improve retention by concrete waste. Decreasing influent phosphate concentration to 20 mg/L decreased PRC to 1.64 g P/kg in concrete waste columns, suggesting fluctuations in greenhouse wastewater composition will affect filter performance. The pH of filter effluent was closely correlated to final P concentration and can likely be used to monitor treatment effectiveness. This study demonstrated that calcium-based materials are promising for the removal of phosphate from greenhouse wastewater, and worthy of further research on scaling up the application to a full-sized system.


Asunto(s)
Fosfatos/aislamiento & purificación , Compuestos de Fósforo/química , Ultrafiltración/métodos , Aguas Residuales/química , Contaminantes Químicos del Agua/aislamiento & purificación , Purificación del Agua/métodos , Adsorción , Agricultura/métodos , Residuos Industriales/prevención & control , Ensayo de Materiales , Fosfatos/química , Aguas Residuales/análisis , Contaminantes Químicos del Agua/química
11.
Environ Technol ; 35(21-24): 2852-62, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25176490

RESUMEN

Phosphate (P) contamination in nutrient-laden wastewater is currently a major topic of discussion in the North American greenhouse industry. Precipitation of P as calcium phosphate minerals using hydrated lime could provide a simple, inexpensive method for retrieval. A combination of batch experiments and chemical equilibrium modelling was used to confirm the viability of this P removal method and determine lime addition rates and pH requirements for greenhouse wastewater of varying nutrient compositions. Lime: P ratio (molar ratio of CaMg(OH)4: PO4‒P) provided a consistent parameter for estimating lime addition requirements regardless of initial P concentration, with a ratio of 1.5 providing around 99% removal of dissolved P. Optimal P removal occurred when lime addition increased the pH from 8.6 to 9.0, suggesting that pH monitoring during the P removal process could provide a simple method for ensuring consistent adherence to P removal standards. A Visual MINTEQ model, validated using experimental data, provided a means of predicting lime addition and pH requirements as influenced by changes in other parameters of the lime-wastewater system (e.g. calcium concentration, temperature, and initial wastewater pH). Hydrated lime addition did not contribute to the removal of macronutrient elements such as nitrate and ammonium, but did decrease the concentration of some micronutrients. This study provides basic guidance for greenhouse operators to use hydrated lime for phosphate removal from greenhouse wastewater.


Asunto(s)
Agricultura , Compuestos de Calcio/química , Óxidos/química , Fosfatos/química , Eliminación de Residuos Líquidos/métodos , Contaminantes Químicos del Agua/química , Precipitación Química , Concentración de Iones de Hidrógeno , Aguas Residuales/química
12.
Plants (Basel) ; 13(3)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38337966

RESUMEN

Indoor-grown Cannabis sativa is commonly transitioned to a 12 h daily photoperiod to promote flowering. However, our previous research has shown that some indoor-grown cannabis cultivars can initiate strong flowering responses under daily photoperiods longer than 12 h. Since longer photoperiods inherently provide higher daily light integrals (DLIs), they may also increase growth and yield. To test this hypothesis, two THC-dominant cannabis cultivars, 'Incredible Milk' (IM) and 'Gorilla Glue' (GG), were grown to commercial maturity at a canopy level PPFD of 540 µmol·m-2·s-1 from white LEDS under 12 h or 13 h daily photoperiods, resulting in DLIs of 23.8 and 25.7 mol·m-2·d-1, respectively. Both treatments were harvested when the plants in the 12 h treatment reached maturity according to established commercial protocols. There was no delay in flowering initiation time in GG, but flowering initiation in IM was delayed by about 1.5 d under 13 h. Stigma browning and trichome ambering also occurred earlier and progressed faster in the 12 h treatment in both cultivars. The vegetative growth of IM plants in the 13 h treatment was greater and more robust. The inflorescence yields were strikingly higher in the 13 h vs. 12 h treatment, i.e., 1.35 times and 1.50 times higher in IM and GG, respectively, which is 4 to 6 times higher than the relative increase in DLIs. The inflorescence concentrations of major cannabinoids in the 13 h treatment were either higher or not different from the 12 h treatment in both cultivars. These results suggest that there may be substantial commercial benefits for using photoperiods longer than 12 h for increasing inflorescence yields without decreasing cannabinoid concentrations in some cannabis cultivars grown in indoor environments.

13.
ACS Appl Mater Interfaces ; 16(5): 6198-6207, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38276960

RESUMEN

Enhancing the durability and functionality of existing materials through sustainable pathways and appropriate structural design represents a time- and cost-effective strategy for the development of advanced wearable devices. Herein, a facile graphene oxide (GO) modification method via the hydroxyl-yne click reaction is present for the first time. By the click coupling between propiolate esters and hydroxyl groups on GO under mild conditions, various functional molecules are successfully grafted onto the GO. The modified GO is characterized by FTIR, XRD, TGA, XPS, and contact angle, proving significantly improved dispersibility in various solvents. Besides the high efficiency, high selectivity, and mild reaction conditions, this method is highly practical and accessible, avoiding the need for prefunctionalizations, metals, or toxic reagents. Subsequently, a rGO-PDMS sponge-based piezoresistive sensor developed by modified GO-P2 as the sensitive material exhibits impressive performance: high sensitivity (335 kPa-1, 0.8-150 kPa), wide linear range (>500 kPa), low detection limit (0.8 kPa), and long-lasting durability (>5000 cycles). Various practical applications have been demonstrated, including body joint movement recognition and real-time monitoring of subtle movements. These results prove the practicality of the methodology and make the rGO-PDMS sponge-based pressure sensor a real candidate for a wide array of wearable applications.

14.
Nat Commun ; 15(1): 5913, 2024 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-39003260

RESUMEN

Traditional catalytic techniques often encounter obstacles in the search for sustainable solutions for converting CO2 into value-added products because of their high energy consumption and expensive catalysts. Here, we introduce a contact-electro-catalysis approach for CO2 reduction reaction, achieving a CO Faradaic efficiency of 96.24%. The contact-electro-catalysis is driven by a triboelectric nanogenerator consisting of electrospun polyvinylidene fluoride loaded with single Cu atoms-anchored polymeric carbon nitride (Cu-PCN) catalysts and quaternized cellulose nanofibers (CNF). Mechanistic investigation reveals that the single Cu atoms on Cu-PCN can effectively enrich electrons during contact electrification, facilitating electron transfer upon their contact with CO2 adsorbed on quaternized CNF. Furthermore, the strong adsorption of CO2 on quaternized CNF allows efficient CO2 capture at low concentrations, thus enabling the CO2 reduction reaction in the ambient air. Compared to the state-of-the-art air-based CO2 reduction technologies, contact-electro-catalysis achieves a superior CO yield of 33 µmol g-1 h-1. This technique provides a solution for reducing airborne CO2 emissions while advancing chemical sustainability strategy.

15.
ACS Sens ; 9(1): 126-138, 2024 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-38170944

RESUMEN

Cardiac monitoring after heart surgeries is crucial for health maintenance and detecting postoperative complications early. However, current methods like rigid implants have limitations, as they require performing second complex surgeries for removal, increasing infection and inflammation risks, thus prompting research for improved sensing monitoring technologies. Herein, we introduce a nanosensor platform that is biodegradable, biocompatible, and integrated with multifunctions, suitable for use as implants for cardiac monitoring. The device has two electrochemical biosensors for sensing lactic acid and pH as well as a pressure sensor and a chemiresistor array for detecting volatile organic compounds. Its biocompatibility with myocytes has been tested in vitro, and its biodegradability and sensing function have been proven with ex vivo experiments using a three-dimensional (3D)-printed heart model and 3D-printed cardiac tissue patches. Moreover, an artificial intelligence-based predictive model was designed to fuse sensor data for more precise health assessment, making it a suitable candidate for clinical use. This sensing platform promises impactful applications in the realm of cardiac patient care, laying the foundation for advanced life-saving developments.


Asunto(s)
Técnicas Biosensibles , Dispositivos Electrónicos Vestibles , Humanos , Inteligencia Artificial , Prótesis e Implantes , Monitoreo Fisiológico
16.
Plants (Basel) ; 13(1)2023 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-38202422

RESUMEN

Blue light plays an important role in regulating plant elongation. However, due to the limitations of older lighting technologies, the responses of plants to pure blue light have not been fully studied, and some of our understandings of the functions of blue light in the literature need to be revisited. This review consolidates and analyzes the diverse findings from previous studies on blue-light-mediated plant elongation. By synthesizing the contrasting results, we uncover the underlying mechanisms and explanations proposed in recent research. Moreover, we delve into the exploration of blue light-emitting diodes (LEDs) as a tool for manipulating plant elongation in controlled-environment plant production, highlighting the latest advancements in this area. Finally, we acknowledge the challenges faced and outline future directions for research in this promising field. This review provides valuable insights into the pivotal role of blue light in plant growth and offers a foundation for further investigations to optimize plant elongation using blue light technology.

17.
STAR Protoc ; 4(4): 102751, 2023 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-37999973

RESUMEN

Creating highly stretchable and robust electrodes while retaining conductivity and stability is challenging. Furthermore, combining these elastic parts with rigid ones brings its own problems due to the discrepancy in firmness between the flexible patches and rigid constructions. Here, we present a protocol to create a stable, conductive, and flexible microneedle sensor patch. We describe steps for using polystyrene-block-polyisoprene-block-polystyrene with silver nanowires, besides fabricating rigid microneedles and combining them together using a thickness-gradient strategy. For complete details on the use and execution of this protocol, please refer to Zheng et al. (2022).1.


Asunto(s)
Nanocables , Dispositivos Electrónicos Vestibles , Plata , Sistemas de Liberación de Medicamentos
18.
Plants (Basel) ; 12(14)2023 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-37514220

RESUMEN

Cannabis sativa ("cannabis" hereafter) is a valuable recent addition to Canada's economy with the legalization for recreational use in 2018. The vast majority of indoor cannabis cultivators use a 12-h light/12-h dark photoperiod to promote flowering. To test the hypothesis that robust flowering initiation responses can be promoted in indoor-grown cannabis cultivars under longer photoperiods, clones of ten drug-type cannabis cultivars were grown under six photoperiod treatments. All treatments were based on a standard 24-h day and included 12 h, 12.5 h, 13 h, 13.5 h, 14 h, and 15 h of light. The plants were grown in a growth chamber for 3 to 4 weeks, receiving an approximate light intensity of 360 µmol·m-2·s-1 from white LEDs. Flowering initiation, defined as the appearance of ≥3 pairs of stigmas at the apex of the primary shoot, occurred in all cultivars under all photoperiod treatments up to 14 h. Delays in flowering initiation time under 14 h vs. 12 h ranged from no delay to approximately 4 days, depending on the cultivar. Some cultivars also initiated flowering under 15 h, but floral tissues did not further develop beyond the initiation phase. Harvest metrics of some cultivars responded quadratically with increasing photoperiod, with ideal levels of key flowering parameters varying between 12 h and 13 h. These results suggest there is potential to increase yield in some indoor-grown cannabis cultivars by using longer than 12-h photoperiods during the flowering stage of production. This is attributed to the inherently higher daily light integrals. Indoor cannabis growers should investigate the photoperiod responses of their individual cultivars to determine the optimal photoperiod for producing floral biomass.

19.
ACS Biomater Sci Eng ; 9(5): 2087-2102, 2023 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-34961316

RESUMEN

The sustainable operation of wearable sensors plays an important role in continuous and longtime health monitoring. Conventional batteries, which are bulky and rigid, do not satisfy these requirements and, rather, cause additional economic burdens and environmental problems by regular replacement of power sources. This article provides a review on an alternative solution in the form of self-powered devices that can harvest energy from the surrounding environment to support the operation of the wearable sensor. The Review starts with an introduction of the self-powered triboelectric nanosensors (TENSs) and its two independent modules: the energy harvester and the sensing module. The Review continues with the TENS-related bioinspired designs for wearable applications, while providing a bird's-eye view of their characteristics and applications. The ongoing challenges and prospects for providing personal healthcare with self-powered TENS are presented and discussed.


Asunto(s)
Suministros de Energía Eléctrica , Dispositivos Electrónicos Vestibles
20.
Plants (Basel) ; 12(3)2023 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-36771506

RESUMEN

In controlled environment production systems, Cannabis sativa (hereafter cannabis) is a commodity with high nutrient demands due to prolific growth under optimized environmental conditions. Since nutrient deficiencies can reduce yield and quality, cultivators need tools to rapidly detect and evaluate deficiency symptoms so corrective actions can be taken quickly to minimize losses. We grew cannabis plants in solution culture with different individual nutrient elements withheld from the solutions to identify deficiency symptoms. Control plants received a complete nutrient recipe, whereas the following single elements were withheld from the respective nutrient deficiency treatments: N, P, K, Ca, Mg, S, Fe, and Mn. The nutrient treatments began when the photoperiod was switched to a 12/12 h (light/dark), and plants were grown to commercial maturity. Plants were monitored daily, and the development of visual deficiency symptoms were recorded. Photographs of each plant were taken weekly. Upon the onset of visual deficiency symptoms, both upper- and lower-canopy foliage were analyzed for nutrient element concentrations. At harvest, plants were evaluated for biomass partitioning, and the cannabinoid composition of inflorescence tissues. This manuscript describes the onset and progression of nutrient deficiency symptoms (with pictures), relates symptomology to foliar nutrient analyses, and contextualizes the relationships between nutrient deficiencies and cannabis growth, yield, and quality. Aboveground vegetative fresh weights were reduced by 73% in the -N treatment and 59% in the -P treatment, compared with the control. All deficiency treatments except for -Fe and -Mn had floral yields reduced by between 33% to 72%, compared with the control. Overall, deficiencies of individual nutrients can substantially reduce vegetative growth and inflorescence yield, although only minor effects were observed in secondary metabolite composition. The onset of individual deficiency symptoms did not always correspond with elemental analysis of foliar tissues. Cultivators should take an integrated approach in diagnosing nutrient deficiencies and take timely corrective actions to optimize productivity and minimize losses to yield and quality.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA