Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Zhongguo Yi Liao Qi Xie Za Zhi ; 46(5): 574-577, 2022 Sep 30.
Artículo en Zh | MEDLINE | ID: mdl-36254490

RESUMEN

This study briefly introduces the basic theory of sterilization, the characteristics of ethylene oxide sterilization for medical devices and the key factors about sterilization effectiveness, analyzes and compares three methods used in the product release of medical devices sterilized by ethylene oxide: test for sterility, traditional release and parametric release, and focuses on the theoretical basis, feasibility, validation requirements, advantages and disadvantages of parametric release.


Asunto(s)
Óxido de Etileno , Esterilización , Esterilización/métodos
2.
J Synchrotron Radiat ; 28(Pt 3): 854-863, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33949993

RESUMEN

The reverse projection protocol results in fast phase-contrast imaging thanks to its compatibility with conventional computed-tomography scanning. Many researchers have proposed variants. However, all these reverse projection methods in grating-based phase-contrast imaging are built on the hypothesis of the synchronous phase of reference shifting curves in the whole field of view. The hypothesis imposes uniformity and alignment requirements on the gratings, thus the field of view is generally limited. In this paper, a generalized reverse projection method is presented analytically for the case of non-uniform reference in grating-based phase tomography. The method is demonstrated by theoretical derivation, numerical simulations and synchrotron radiation experiments. The influence of imaging position to sensitivity, and the phase-wrapping phenomenon are also discussed. The proposed method combines the advantages of the high efficiency of the reverse projection method and the universal applicability of the phase-stepping method. The authors believe that the method would be used widely in fast and dose-constrained imaging.

3.
Opt Lett ; 46(11): 2791-2794, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-34061115

RESUMEN

In this work, a novel, to the best of our knowledge, approach based on an x-ray thin lens imaging theory is proposed to predict the angular sensitivity responses of dual-phase-grating differential phase contrast (DPC) interferometers. Experimental validations have been performed to demonstrate the high accuracy of theoretical predictions using two different setups: one with real source images and the other with virtual source images. This new sensitivity calculation method is helpful to optimize the DPC imaging performance of a dual-phase-grating system.

4.
Opt Express ; 28(7): 9786-9801, 2020 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-32225579

RESUMEN

In this work, we developed a new theoretical framework using wave optics to explain the working mechanism of the grating based X-ray differential phase contrast imaging (XPCI) interferometer systems consist of more than one phase grating. Under the optical reversibility principle, the wave optics interpretation was simplified into the geometrical optics interpretation, in which the phase grating was treated as a thin lens. Moreover, it was derived that the period of an arrayed source, e.g., the period of a source grating, is always equal to the period of the diffraction fringe formed on the source plane. When a source grating is utilized, the theory indicated that it is better to keep the periods of the two phase gratings different to generate large period diffraction fringes. Experiments were performed to validate these theoretical findings.

5.
J Synchrotron Radiat ; 25(Pt 4): 1222-1228, 2018 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-29979185

RESUMEN

Grating-based X-ray differential phase-contrast imaging has attracted a great amount of attention and has been considered as a potential imaging method in clinical medicine because of its compatibility with the traditional X-ray tube source and the possibility of a large field of view. Moreover, phase-contrast computed tomography provides three-dimensional phase-contrast visualization. Generally, two-dimensional information retrieval performed on every projection is required prior to three-dimensional reconstruction in phase-contrast computed tomography. In this paper, a three-dimensional information retrieval method to separate absorption and phase information directly from two reconstructed images is derived. Theoretical derivations together with numerical simulations have been performed to confirm the feasibility and veracity of the proposed method. The advantages and limitations compared with the reverse projection method are also discussed. Owing to the reduced data size and the absence of a logarithm operation, the computational time for information retrieval is shortened by the proposed method. In addition, the hybrid three-dimensional images of absorption and phase information were reconstructed using an absorption reconstruction algorithm, hence the existing data pre-processing methods and iterative reconstruction algorithms in absorption reconstruction may be utilized in phase reconstruction immediately.

6.
Opt Express ; 24(6): 5829-45, 2016 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-27136780

RESUMEN

Microscopy techniques using visible photons, x-rays, neutrons, and electrons have made remarkable impact in many scientific disciplines. The microscopic data can often be expressed as the convolution of the spatial distribution of certain properties of the specimens and the inherent response function of the imaging system. The x-ray grating interferometer (XGI), which is sensitive to the deviation angle of the incoming x-rays, has attracted significant attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the comprehensive and analytical theoretical framework is yet to be presented. Herein, we propose a theoretical framework termed angular signal radiography (ASR) to describe the imaging process of the XGI system in a classical, comprehensive and analytical manner. We demonstrated, by means of theoretical deduction and synchrotron based experiments, that the spatial distribution of specimens' physical properties, including absorption, refraction and scattering, can be extracted by ASR in XGI. Implementation of ASR in XGI offers advantages such as simplified phase retrieval algorithm, reduced overall radiation dose, and improved image acquisition speed. These advantages, as well as the limitations of the proposed method, are systematically investigated in this paper.

7.
J Synchrotron Radiat ; 22(3): 786-95, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25931098

RESUMEN

A description of the rocking curve in diffraction enhanced imaging (DEI) is presented in terms of the angular signal response function and a simple multi-information retrieval algorithm based on the cosine function fitting. A comprehensive analysis of noise properties of DEI is also given considering the noise transfer characteristic of the X-ray source. The validation has been performed with synchrotron radiation experimental data and Monte Carlo simulations based on the Geant4 toolkit combined with the refractive process of X-rays, which show good agreement with each other. Moreover, results indicate that the signal-to-noise ratios of the refraction and scattering images are about one order of magnitude better than that of the absorption image at the edges of low-Z samples. The noise penalty is drastically reduced with the increasing photon flux and visibility. Finally, this work demonstrates that the analytical method can build an interesting connection between DEI and GDPCI (grating-based differential phase contrast imaging) and is widely suitable for a variety of measurement noise in the angular signal response imaging prototype. The analysis significantly contributes to the understanding of noise characteristics of DEI images and may allow improvements to the signal-to-noise ratio in biomedical and material science imaging.

8.
Opt Lett ; 38(12): 2068-70, 2013 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-23938979

RESUMEN

We present a x-ray microscopy technique based on structured illumination in a microscope that characterizes the size of the subresolution-limit features. The technique is effective for characterizing fine structures substantially beyond the Rayleigh resolution of the microscope. We carried out optical experiments to demonstrate the basic principle of this new technique. Experimental results show good agreement with theoretical predictions. This technique should find a wide range of important imaging applications with a feature size down to nanometer scale, such as oil and gas reservoir rocks, advanced composites, and functional nanodevices and materials.

9.
Eur Radiol ; 23(2): 417-23, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22903640

RESUMEN

OBJECTIVES: To determine whether phase-contrast X-ray imaging can be used to visualise directly the accumulated extracellular matrix proteins associated with liver fibrosis in common bile duct ligated mice. METHODS: Twenty-six-week-old C57BL female mice were randomised into three groups. In groups 1 (n = 5) and 2 (n = 10), common bile duct ligation was conducted to produce secondary biliary cirrhosis. Mouse livers were then excised 15 (group 1) and 40 days (group 2) after the ligation of the common bile duct for imaging. In the control group, the livers of 5 mice were excised 40 days after the sham operation. Images were then acquired using the analyser crystal set at different positions of the rocking curve. RESULTS: The results show that the fibrotic septa and hepatic lobules enclosed by fibrotic septa can be visualised clearly at the whole organ level via phase-contrast X-ray imaging without any contrast agent. CONCLUSION: These results suggest that phase-contrast X-ray imaging can easily reveal the accumulated extracellular matrix proteins associated with liver fibrosis without using any contrast agent and has great potential in the study of liver fibrosis.


Asunto(s)
Medios de Contraste , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/patología , Radiografía/métodos , Animales , Biopsia con Aguja , Conducto Colédoco/cirugía , Modelos Animales de Enfermedad , Femenino , Hepatectomía/métodos , Inmunohistoquímica , Ligadura , Ratones , Ratones Endogámicos C57BL , Distribución Aleatoria , Valores de Referencia , Sensibilidad y Especificidad , Técnicas de Cultivo de Tejidos
10.
Proc Natl Acad Sci U S A ; 107(31): 13576-81, 2010 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-20643971

RESUMEN

Phase sensitive X-ray imaging methods can provide substantially increased contrast over conventional absorption-based imaging and therefore new and otherwise inaccessible information. The use of gratings as optical elements in hard X-ray phase imaging overcomes some of the problems that have impaired the wider use of phase contrast in X-ray radiography and tomography. So far, to separate the phase information from other contributions detected with a grating interferometer, a phase-stepping approach has been considered, which implies the acquisition of multiple radiographic projections. Here we present an innovative, highly sensitive X-ray tomographic phase-contrast imaging approach based on grating interferometry, which extracts the phase-contrast signal without the need of phase stepping. Compared to the existing phase-stepping approach, the main advantages of this new method dubbed "reverse projection" are not only the significantly reduced delivered dose, without the degradation of the image quality, but also the much higher efficiency. The new technique sets the prerequisites for future fast and low-dose phase-contrast imaging methods, fundamental for imaging biological specimens and in vivo studies.


Asunto(s)
Dosis de Radiación , Radiografía/métodos , Tomografía por Rayos X/métodos , Animales , Ratones , Ratas , Factores de Tiempo
11.
IEEE Trans Biomed Eng ; 70(1): 15-26, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35679372

RESUMEN

OBJECTIVE: Quantitative technique based on In-line phase-contrast computed tomography with single scanning attracts more attention in application due to the flexibility of the implementation. However, the quantitative results usually suffer from artifacts and noise since the phase retrieval and reconstruction are independent ("two-step") without feedback from the original data. The work aims to investigate a method for material quantitation to improve the image quality of In-line tomography within single scanning. METHOD: An iterative method based Fresnel diffraction imaging model is developed in this work, which directly reconstructs the refractive index decrement δ and imaginary ß of the object from observed data ("one-step"). Moreover, high-quality material decomposition results are obtained by using a linear approximation in the iterative process. RESULTS: Compared with the existing methods, Our method shows a higher peak signal-to-noise ratio and structural similarity in numerical experimental results. Additionally, the quantitation accuracy of the proposed method is greater than 97.2 % by calculating the equivalent atomic number of the decomposed basic material in the real experiment. CONCLUSION: We demonstrate that this one-step method greatly reduces noise and improves quantitative reconstruction and decomposition results. SIGNIFICANCE: This algorithm has the potential for quantitative imaging research using In-line tomography in future biomedical applications.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Tomografía Computarizada por Rayos X , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Artefactos
12.
J Synchrotron Radiat ; 19(Pt 6): 1021-8, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23093765

RESUMEN

A full-field transmission X-ray microscope (TXM) operating continuously from 5 keV to 12 keV with fluorescence mapping capability has been designed and constructed at the Beijing Synchrotron Radiation Facility, a first-generation synchrotron radiation facility operating at 2.5 GeV. Spatial resolution better than 30 nm has been demonstrated using a Siemens star pattern in both absorption mode and Zernike phase-contrast mode. A scanning-probe mode fluorescence mapping capability integrated with the TXM has been shown to provide 50 p.p.m. sensitivity for trace elements with a spatial resolution (limited by probing beam spot size) of 20 µm. The optics design, testing of spatial resolution and fluorescence sensitivity are presented here, including performance measurement results.

13.
Opt Lett ; 37(17): 3708-10, 2012 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-22940998

RESUMEN

A fast discrete curvelet transform based focus-stacking algorithm for extending the depth of focus of a transmission x-ray microscope (TXM) is presented. By analyzing an image stack of a sample taken in a Z-scan, a fully in-focus image can be generated by the proposed scheme. With the extended depth of focus, it is possible to obtain 3D structural information over a large volume at nanometer resolution. The focus-stacking method has been demonstrated using a dataset taken with a laboratory x-ray source based TXM system. The possibility and limitations of generalizing this method to a synchrotron based TXM are also discussed. We expect the proposed method to be of important impact in 3D x-ray microscopy.


Asunto(s)
Microscopía/métodos , Fenómenos Ópticos , Algoritmos , Rayos X
14.
Anal Bioanal Chem ; 404(5): 1303-9, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22733246

RESUMEN

In this contribution we discuss the possibility of designing a modified transmission X-ray microscope by using fractal zone plates (Fzps) as diffractive optical elements. In the modified transmission X-ray microscope optical layout, we first introduced a fractal zone plate as the microscope objective. Indeed, a fractal zone plate cannot only be used as an image-forming component but also as a condenser element to achieve an extended depth of field. Numerical analysis reveals that fractal zone plates and conventional Fresnel zone plates have similar imaging capabilities under different coherent illumination. Using a fractal zone plate as a condenser we also simulated axial irradiance. Results confirm that fractal zone plates can improve focusing capability with an extended depth of field. Although preliminary, these simulations clearly reveal that fractal zone plates, when available, will be of great help in microscope layouts, in particular for foreseen high-resolution applications in the "water window" as strongly required in biological research.

15.
Anal Bioanal Chem ; 404(5): 1327-30, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22763718

RESUMEN

X-ray microscopy based on synchrotron radiation has become a fundamental tool in biology and life sciences to visualize the morphology of a specimen. These studies have particular requirements in terms of radiation damage and the image exposure time, which directly determines the total acquisition speed. To monitor and improve these key parameters, we present a novel X-ray microscopy method using a high-resolution zone plate as the objective and the matching condenser. Numerical simulations based on the scalar wave field theory validate the feasibility of the method and also indicate the performance of X-ray microscopy is optimized most with sub-10-nm-resolution zone plates. The proposed method is compatible with conventional X-ray microscopy techniques, such as computed tomography, and will find wide applications in time-resolved and/or dose-sensitive studies such as living cell imaging.


Asunto(s)
Microscopía/métodos , Sincrotrones , Algoritmos , Diseño de Equipo , Microscopía/instrumentación , Proteínas/ultraestructura , Rayos X
16.
Opt Express ; 19(2): 540-5, 2011 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-21263593

RESUMEN

An alternative method for quantitative phase retrieval in a transmission X-ray microscope system at sub-50-nm resolution is presented. As an alternative to moving the sample in the beam direction in order to analyze the propagation-introduced phase effect, we have illuminated the TXM using X-rays of different energy without any motor movement in the TXM system. Both theoretical analysis and experimental studies have confirmed the feasibility and the advantage of our method, because energy tuning can be performed with very high energy resolution using a double crystal monochromator at a synchrotron beam line, and there is zero motor error in TXM system in our approach. High-spatial-resolution phase retrieval is accomplished using the proposed method.


Asunto(s)
Colorimetría/métodos , Iluminación/métodos , Microscopía Electrónica de Transmisión/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
17.
Anal Bioanal Chem ; 401(3): 817-25, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21604168

RESUMEN

X-ray micro-CT is a powerful tool to visualize without damage details of the inner structures of beetles, the largest order of insects with a hard external skeleton. This contribution shows the three-dimensional (3D) reconstruction of the head morphology of three rove beetle species (Insecta, Coleoptera, Staphylinidae)--Noddia sp., Creophilus maxillosus, and Hesperosoma sp.--using X-ray microtomography at a spatial resolution of 6 µm. The details of skeletal muscle fiber insertions are described, giving a comprehensive overview of mandible mobility and organization. With the support of 3D rendering, we discuss the relationship among the mandible forms, the development of the muscles controlling the movement, and the head morphology. The well-developed posterior part of the head capsule is always accompanied by a well-developed mandible, a large adductor muscle, and a large apodeme for the wide areas of the muscle fiber attachment. In Noddia sp., muscles connected to the posterolateral angle of the head capsule are mainly short muscles, whereas in Creophilus maxillosus, the latter are mainly long muscles, and in Hesperosoma sp. no mandible adductor muscle fibers are present on the posterolateral angle of the head capsule. These results offer new invaluable information regarding the biting functions of beetle mandibles and the trend of their morphological change during their long-term evolution.


Asunto(s)
Escarabajos/anatomía & histología , Animales , Mandíbula/diagnóstico por imagen , Músculos/diagnóstico por imagen , Tomografía Computarizada por Rayos X
18.
Anal Bioanal Chem ; 401(3): 803-8, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21479546

RESUMEN

Three-dimensional (3D) topographic structures of acupuncture points were investigated by using synchrotron radiation in-line X-ray phase contrast computerized tomography. Two acupuncture points, named Zhongji (RN3) and Zusanli (ST36), were studied. We found an accumulation of microvessels at each acupuncture point region. Images of the tissues surrounding the acupuncture points do not show such kinds of structure. This is the first time that 3D images have revealed the specific structures of acupuncture points.


Asunto(s)
Puntos de Acupuntura , Microvasos/diagnóstico por imagen , Sincrotrones , Tomografía Computarizada por Rayos X , Animales , Conejos
19.
Anal Bioanal Chem ; 401(3): 865-70, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21667349

RESUMEN

The recent use of a one-dimensional (1D) X-ray Talbot interferometer has triggered great interest in X-ray differential phase contrast imaging. As an improved version of a 1D interferometer, the development of two-dimensional (2D) grating interferometry strongly stimulated applications of grating-based imaging. In the framework of Fresnel diffraction theory, we investigated the self-image of 2D-phase gratings under partially coherent illumination. The fringe visibility of the self-image has been analyzed as a function of the spatial coherence length. From the viewpoint of self-image visibility, it is possible to find the optimal 2D grid for 2D X-ray grating interferometer imaging. Numerical simulations have been also carried out for quantitative evaluation. Results, in good agreement with theoretical analysis, indicate the spatial coherence requirements of the radiation illuminating a 2D grating interferometer. Moreover, our results can be used to optimize performances of a 2D grating interferometer and for further theoretical and experimental research on grating-based imaging systems.

20.
Anal Bioanal Chem ; 401(3): 837-44, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21626196

RESUMEN

Impressive developments in X-ray imaging are associated with X-ray phase contrast computed tomography based on grating interferometry, a technique that provides increased contrast compared with conventional absorption-based imaging. A new "single-step" method capable of separating phase information from other contributions has been recently proposed. This approach not only simplifies data-acquisition procedures, but, compared with the existing phase step approach, significantly reduces the dose delivered to a sample. However, the image reconstruction procedure is more demanding than for traditional methods and new algorithms have to be developed to take advantage of the "single-step" method. In the work discussed in this paper, a fast iterative image reconstruction method named OSEM (ordered subsets expectation maximization) was applied to experimental data to evaluate its performance and range of applicability. The OSEM algorithm with different subsets was also characterized by comparison of reconstruction image quality and convergence speed. Computer simulations and experimental results confirm the reliability of this new algorithm for phase-contrast computed tomography applications. Compared with the traditional filtered back projection algorithm, in particular in the presence of a noisy acquisition, it furnishes better images at a higher spatial resolution and with lower noise. We emphasize that the method is highly compatible with future X-ray phase contrast imaging clinical applications.


Asunto(s)
Encéfalo/diagnóstico por imagen , Imagenología Tridimensional/métodos , Tomografía Computarizada por Rayos X , Algoritmos , Animales , Simulación por Computador , Reconocimiento de Normas Patrones Automatizadas , Ratas , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA