Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 133
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Int Orthop ; 48(7): 1733-1742, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38563992

RESUMEN

PURPOSE: Although the principles of hip reconstruction are consistent, due to lack of reliable anatomical landmarks, how to decide the acetabular cup reaming centre intraoperatively in Crowe IV patients with developmental dysplasia of the hip (DDH) remains unclear. This study aims to address this question. METHODS: Fifty-eight Crowe IV patients were enrolled from 2017 to 2019. By examining our previous clinical data, we analyzed the anatomical morphology of Crowe IV acetabulum and proposed a method of locating intraoperative reaming centering for implantation of a standard-sized acetabular cup, which is the upper two thirds of the posterior border of the true acetabulum. All patients included in this study were reamed according to this method. The average postoperative follow-up was 4.1 years (3-5 years). The position of the centre of rotation (COR), cup coverage (CC), and optimal range of joint motion (ROM) were examined by 3D computer simulation measurement. Postoperative complications and hip Harris score were collected and analyzed. RESULTS: The morphology of the type IV DDH true acetabulum was mostly triangular. The intraoperative reaming centre were centered on the upper two thirds of the posterior border of the true acetabulum. The postoperative 3D CC was 80.20% ± 7.63% (64.68-90.24%, 44-48-mm cup size). The patients' mean Harris score improved from 39.7 ± 20.4 preoperatively to 91.5 ± 8.12 at the last follow-up. CONCLUSION: Our study demonstrated that satisfactory CC and clinical results could be achieved by implanting a standard-sized cup with the reaming centre on the upper two thirds of the posterior border of the true acetabulum.


Asunto(s)
Acetábulo , Artroplastia de Reemplazo de Cadera , Displasia del Desarrollo de la Cadera , Humanos , Masculino , Femenino , Estudios Retrospectivos , Acetábulo/cirugía , Persona de Mediana Edad , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/instrumentación , Displasia del Desarrollo de la Cadera/cirugía , Anciano , Adulto , Rango del Movimiento Articular , Prótesis de Cadera
2.
J Nanobiotechnology ; 21(1): 259, 2023 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-37550715

RESUMEN

Autogenous bone grafting has long been considered the gold standard for treating critical bone defects. However, its use is plagued by numerous drawbacks, such as limited supply, donor site morbidity, and restricted use for giant-sized defects. For this reason, there is an increasing need for effective bone substitutes to treat these defects. Mollusk nacre is a natural structure with outstanding mechanical property due to its notable "brick-and-mortar" architecture. Inspired by the nacre architecture, our team designed and fabricated a nacre-mimetic cerium-doped layered nano-hydroxyapatite/chitosan layered composite scaffold (CeHA/CS). Hydroxyapatite can provide a certain strength to the material like a brick. And as a polymer material, chitosan can slow down the force when the material is impacted, like an adhesive. As seen in natural nacre, the combination of these inorganic and organic components results in remarkable tensile strength and fracture toughness. Cerium ions have been demonstrated exceptional anti-osteoclastogenesis capabilities. Our scaffold featured a distinct layered HA/CS composite structure with intervals ranging from 50 to 200 µm, which provided a conducive environment for human bone marrow mesenchymal stem cell (hBMSC) adhesion and proliferation, allowing for in situ growth of newly formed bone tissue. In vitro, Western-blot and qPCR analyses showed that the CeHA/CS layered composite scaffolds significantly promoted the osteogenic process by upregulating the expressions of osteogenic-related genes such as RUNX2, OCN, and COL1, while inhibiting osteoclast differentiation, as indicated by reduced TRAP-positive osteoclasts and decreased bone resorption. In vivo, calvarial defects in rats demonstrated that the layered CeHA/CS scaffolds significantly accelerated bone regeneration at the defect site, and immunofluorescence indicated a lowered RANKL/OPG ratio. Overall, our results demonstrate that CeHA/CS scaffolds offer a promising platform for bone regeneration in critical defect management, as they promote osteogenesis and inhibit osteoclast activation.


Asunto(s)
Quitosano , Nácar , Ratas , Humanos , Animales , Quitosano/farmacología , Quitosano/química , Durapatita/farmacología , Durapatita/química , Andamios del Tejido/química , Nácar/farmacología , Regeneración Ósea , Osteogénesis , Transducción de Señal , Diferenciación Celular , Ingeniería de Tejidos/métodos
3.
BMC Musculoskelet Disord ; 23(1): 432, 2022 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-35534887

RESUMEN

BACKGROUND: Accurate assessment of acetabular defects and designing precise and feasible surgical plans are essential for positive outcomes of hip revision arthroplasty. Additive manufacturing (AM) is a novel technique to print physical object models. We propose a three-dimensional acetabular bone defect classification system aided with AM model, and further assess its reliability and validity under blinded conditions. METHODS: We reviewed 104 consecutive patients who underwent hip revision arthroplasty at our department between January 2014 and December 2019, of whom 45 had AM models and were included in the reliability and validity tests. Three orthopedic surgeons retrospectively evaluated the bone defects of these 45 patients with our proposed classification, made surgical plans, and repeated the process after 2 weeks. The reliability and validity of the classification results and corresponding surgical plans were assessed using the intra-class correlation coefficient or kappa correlation coefficient. RESULTS: The reliability and validity of the classification results were excellent. The mean initial intra-class correlation coefficient for inter-observer reliability was 0.947, which increased to 0.972 when tested a second time. The intra-observer reliability ranged from 0.958 to 0.980. Validity of the classification results also showed a high kappa correlation coefficient of 0.951-0.967. When considering corresponding surgical plans, the reliability and validity were also excellent, with intra-class correlation coefficients and kappa correlation coefficients measuring all over 0.9. CONCLUSIONS: This three-dimensional acetabular defect classification has excellent reliability and validity. Using this classification system and AM models, accurate assessment of bone defect and reliable surgical plans could be achieved. This classification aided with AM is a promising tool for surgeons for preoperative evaluation.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/métodos , Humanos , Variaciones Dependientes del Observador , Reoperación , Reproducibilidad de los Resultados , Estudios Retrospectivos
4.
BMC Musculoskelet Disord ; 23(1): 437, 2022 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-35546655

RESUMEN

BACKGROUND: Mechanical failure, power shortage, and inadvertent contamination of the oscillating saw occasionally occurs in actualizing femoral neck osteotomy during total hip arthroplasty (THA); however, no appropriate alternative solution is currently available. This study aimed to introduce a novel osteotomy instrumentation (fretsaw, jig, cable passer hook) as a substitute tool while the oscillating saw was unavailable during THA. METHODS: This study included 40 patients (40 hips) who underwent femoral neck osteotomy during primary THA using the new osteotomy instrumentation (n = 20) and the oscillating saw (n = 20). Clinical data and intraoperative findings of all patients were evaluated. RESULTS: The mean osteotomy time was 22.3 ± 3.1 s (range, 17-30 s) and 29.4 ± 3.7 s (range, 25-39 s) in the oscillating saw group and in the new osteotomy instrumentation group, respectively (P < 0.001). The Harris Hip Score (HHS) improved in both groups; the mean HSS was 82.3 ± 2.5 and 83.3 ± 3.5 in the oscillating saw group and new osteotomy instrumentation group at 6 months after surgery, respectively (P = 0.297). CONCLUSIONS: The original osteotomy instrumentation can be an ideal substitute tool for femoral neck osteotomy in THA, especially when the oscillating saw is unavailable or malfunctioning.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación Congénita de la Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Fémur/cirugía , Cuello Femoral/diagnóstico por imagen , Cuello Femoral/cirugía , Luxación Congénita de la Cadera/cirugía , Humanos , Osteotomía , Estudios Retrospectivos , Resultado del Tratamiento
5.
J Nanobiotechnology ; 19(1): 11, 2021 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-33413447

RESUMEN

BACKGROUND: Breast cancer bone metastasis has become one of the most common complications; however, it may cause cancer recurrence and bone nonunion, as well as local bone defects. METHODS: Herein, In vitro, we verified the effect of bioscaffold materials on cell proliferation and apoptosis through a CCK8 trial, staining of live/dead cells, and flow cytometry. We used immunofluorescence technology and flow cytometry to verify whether bioscaffold materials regulate macrophage polarization, and we used ALP staining, alizarin red staining and PCR to verify whether bioscaffold material promotes bone regeneration. In vivo, we once again studied the effect of bioscaffold materials on tumors by measuring tumor volume in mice, Tunel staining, and caspase-3 immunofluorescence. We also constructed a mouse skull ultimate defect model to verify the effect on bone regeneration. RESULTS: Graphene oxide (GO) nanoparticles, hydrated CePO4 nanorods and bioactive chitosan (CS) are combined to form a bioactive multifunctional CePO4/CS/GO scaffold, with characteristics such as photothermal therapy to kill tumors, macrophage polarization to promote blood vessel formation, and induction of bone formation. CePO4/CS/GO scaffold activates the caspase-3 proteasein local tumor cells, thereby lysing the DNA between nucleosomes and causing apoptosis. On the one hand, the as-released Ce3+ ions promote M2 polarization of macrophages, which secretes vascular endothelial growth factor (VEGF) and Arginase-1 (Arg-1), which promotes angiogenesis. On the other hand, the as-released Ce3+ ions also activated the BMP-2/Smad signaling pathway which facilitated bone tissue regeneration. CONCLUSION: The multifunctional CePO4/CS/GO scaffolds may become a promising platform for therapy of breast cancer bone metastases.


Asunto(s)
Neoplasias de la Mama/tratamiento farmacológico , Cerio/química , Grafito/farmacología , Nanotubos/química , Fosfatos/química , Células 3T3 , Animales , Materiales Biocompatibles , Neoplasias Óseas/tratamiento farmacológico , Neoplasias Óseas/metabolismo , Regeneración Ósea , Huesos , Neoplasias de la Mama/metabolismo , Proliferación Celular , Quitosano , Modelos Animales de Enfermedad , Femenino , Macrófagos , Ratones , Metástasis de la Neoplasia , Osteogénesis , Células RAW 264.7 , Ratas , Ratas Sprague-Dawley , Factor A de Crecimiento Endotelial Vascular
6.
BMC Musculoskelet Disord ; 22(1): 428, 2021 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-33964907

RESUMEN

BACKGROUND: Single 6 ml Hylan G-F 20 injection, is indicated for knee osteoarthritis patients who have failed to respond to non-pharmacologic therapy and/or simple analgesics. To obtain more thorough understanding of the clinical efficacy and safety, a randomized clinical trial was conducted comparing intra-articular (IA) administration of single 6 ml Hylan G-F 20 injection versus placebo in knee OA patients of Chinese ethnicity. METHODS: This was a randomized, multi-center, double-blind, placebo-controlled clinical trial conducted in 21 centers across China. Four hundred forty adults with knee OA received a single 6 ml Hylan G-F 20 or placebo injection and were evaluated for clinical efficacy and safety outcomes over 26 weeks. Western Ontario and McMaster Universities OA (WOMAC) A1 index, treatment-emergent adverse events (TEAEs) and standard safety parameters were measured at pre-injection, and at weeks 1, 4, 8, 12, 16, 20 and 26 post-injection. RESULTS: Four hundred forty patients (male: 98 [22.3%]; female: 342 [77.7%]) were randomized. The mean age [standard deviation (SD)] was 61.5 (7.9) years. All patients were of East Asian ethnicity. Mean WOMAC A1 score at baseline was 5.3 (1.2) and 5.2 (1.3) in single 6 ml Hylan G-F 20 injection and placebo groups, respectively. Significant reductions of WOMAC A1 score were observed in both treatment groups when compared to baseline at 26 weeks post-injection, with the mean reduction of [standard error (SE)/percentage] -2.146 (0.108)/- 40.5% and - 2.271 (0.110) /- 43.7% in the single 6 ml Hylan G-F 20 injection and the placebo groups, respectively. Additionally, clinically important reductions in pain at 26 weeks was reported in 67.0 and 68.2% in single 6 ml Hylan G-F 20 injection and placebo groups (p = 0.36). Regarding safety, TEAEs were similar between the two treatment groups (hylan G-F 20 single: 61.5%; placebo: 64.5%). CONCLUSIONS: While the magnitude of the effect of a single 6 ml Hylan G-F 20 injection in this study is consistent with previously published literature with respect to the efficacy and safety of the drug, the current study shows a strong IA placebo effect and did not established superiority of single 6 ml Hylan G-F 20 injection over IA placebo in Chinese knee OA patients. TRIAL REGISTRATION: Prospectively registered Jun 16, 2017 at www.clinicaltrials.gov ( NCT03190369 ).


Asunto(s)
Osteoartritis de la Rodilla , Anciano , China/epidemiología , Método Doble Ciego , Femenino , Humanos , Ácido Hialurónico/análogos & derivados , Inyecciones Intraarticulares , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico , Osteoartritis de la Rodilla/tratamiento farmacológico , Resultado del Tratamiento
7.
J Cell Mol Med ; 24(5): 3203-3216, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32053272

RESUMEN

Aseptic loosening caused by wear particles is a common complication after total hip arthroplasty. We investigated the effect of the quercetin on wear particle-mediated macrophage polarization, inflammatory response and osteolysis. In vitro, we verified that Ti particles promoted the differentiation of RAW264.7 cells into M1 macrophages through p-38α/ß signalling pathway by using flow cytometry, immunofluorescence assay and small interfering p-38α/ß RNA. We used enzyme-linked immunosorbent assays to confirm that the protein expression of M1 macrophages increased in the presence of Ti particles and that these pro-inflammatory factors further regulated the imbalance of OPG/RANKL and promoted the differentiation of osteoclasts. However, this could be suppressed, and the protein expression of M2 macrophages was increased by the presence of the quercetin. In vivo, we revealed similar results in the mouse skull by µ-CT, H&E staining, immunohistochemistry and immunofluorescence assay. We obtained samples from patients with osteolytic tissue. Immunofluorescence analysis indicated that most of the macrophages surrounding the wear particles were M1 macrophages and that pro-inflammatory factors were released. Titanium particle-mediated M1 macrophage polarization, which caused the release of pro-inflammatory factors through the p-38α/ß signalling pathway, regulated OPG/RANKL balance. Macrophage polarization is expected to become a new clinical drug therapeutic target.


Asunto(s)
Osteonecrosis/tratamiento farmacológico , Osteoprotegerina/genética , Quercetina/farmacología , Ligando RANK/genética , Proteínas Quinasas p38 Activadas por Mitógenos/genética , Animales , Artroplastia de Reemplazo de Cadera/efectos adversos , Diferenciación Celular/efectos de los fármacos , Polaridad Celular/efectos de los fármacos , Regulación del Desarrollo de la Expresión Génica/efectos de los fármacos , Humanos , Macrófagos/efectos de los fármacos , Ratones , Osteoclastos/efectos de los fármacos , Osteonecrosis/inducido químicamente , Osteonecrosis/genética , Osteonecrosis/patología , Células RAW 264.7 , Cráneo/efectos de los fármacos , Cráneo/crecimiento & desarrollo , Cráneo/patología , Titanio/efectos adversos
8.
BMC Musculoskelet Disord ; 21(1): 623, 2020 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-32957942

RESUMEN

BACKGROUND: The purpose of this study was to investigate the association between the severity of Developmental dysplasia of the hip (DDH) and the abnormality in pelvic incidence (PI). METHODS: This was a retrospective study analyzing 53 DDH patients and 53 non-DDH age-matched controls. Computed tomography images were used to construct three-dimensional pelvic model. The Crowe classification was used to classify the severity of DDH. The midpoint of the femoral head centers and sacral endplates were projected to the sagittal plane of the pelvis. The PI was defined as the angle between a line perpendicular to the sacral plate at its midpoint and a line connecting this point to the axis of the femoral heads. Independent sample t-tests were used to compare the differences between the PI of DDH group and the non-DDH controls group. Kendall's coefficient of concordance was used to determine the correlation between the severity of DDH and PI. RESULTS: Patients with DDH had a significantly (p = 0.041) higher PI than the non-DDH controls (DDH 47.6 ± 8.2°, normal 44.2 ± 8.8°). Crowe type I patients had a significantly (p = 0.038) higher PI (48.2 ± 7.6°) than the non-DDH controls. No significant difference between the PI in Crowe type II or III patients and the PI in non-DDH controls were found (Crowe type II, 50.2 ± 9.6°, p = 0.073; Crowe type III, 43.8 ± 7.2°, p = 0.930). No correlation was found between the severity of DDH and the PI (r = 0.091, p = 0.222). CONCLUSIONS: No correlation was found between the severity of DDH and the PI. The study confirmed that the PI in DDH (Crowe type I) group was higher than that of the non-DDH control group, while the PI does not correlate with the severity of DDH.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Displasia del Desarrollo de la Cadera , Luxación Congénita de la Cadera , Cabeza Femoral/diagnóstico por imagen , Luxación Congénita de la Cadera/diagnóstico por imagen , Luxación Congénita de la Cadera/epidemiología , Luxación Congénita de la Cadera/cirugía , Humanos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
9.
J Arthroplasty ; 35(2): 457-464, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31668697

RESUMEN

BACKGROUND: Preoperative planning is fundamental for total hip arthroplasty. This study investigated the optimal femoral neck level for measuring femoral anteversion to predict postoperative stem anteversion in developmental dysplasia of the hip and determined the predictive role of average anteversion based on the sagittal 3-point fixation. METHODS: Sixty-two Crowe type II/III dysplastic hips that underwent total hip arthroplasty were retrospectively analyzed. Preoperative and postoperative anteversion was measured via 2-dimensional computed tomography. Anterior and posterior cortex anteversions were measured at 6 levels of the proximal femur. Femoral anteversion at each level was calculated. Average anterior (lesser trochanter) and posterior cortex anteversions (femoral neck) were calculated based on the sagittal 3-point fixation. RESULTS: From the lesser trochanter to head-neck junction, femoral anteversion decreased gradually from more to less than stem anteversion. For hips with femoral neck height ≥10 mm, femoral anteversion at the 10-mm level above the lesser trochanter proximal base showed no significant difference with stem anteversion, with a good correlation for the single-wedge and an excellent correlation for the double-wedge stem. Average anterior (lesser trochanter proximal base) and posterior cortex anteversions (femoral neck at 10 mm above the lesser trochanter proximal base) showed no significant difference from stem anteversion, with excellent correlations. CONCLUSION: For Crowe type II/III hips with femoral neck height ≥10 mm, the 10-mm level above the lesser trochanter proximal base is an optimal choice for measuring femoral anteversion to predict postoperative stem anteversion. The average of anterior cortex anteversion at the lesser trochanter and posterior cortex anteversion at the femoral neck has a predictive role.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación Congénita de la Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Fémur/diagnóstico por imagen , Fémur/cirugía , Cuello Femoral/diagnóstico por imagen , Cuello Femoral/cirugía , Luxación Congénita de la Cadera/diagnóstico por imagen , Luxación Congénita de la Cadera/cirugía , Humanos , Estudios Retrospectivos
10.
Nanomedicine ; 18: 336-346, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30419364

RESUMEN

Bioglass scaffolds have great application potentials in orthopedics, and Ursolic acid (UA) can effectively promote in vivo new bone formation. Herein, we for the first time developed the mesoporous bioglass/chitosan porous scaffolds loaded with UA (MBG/CS/UA) for enhanced bone regeneration. The MBG microspheres with particle sizes of ~300 nm and pore sizes of ~3.9 nm were uniformly dispersed on the CS films. The mesoporous structure within the MBG microspheres and the hydrogen bonding between the scaffolds and UA drugs made the MBG/CS/UA scaffolds have controlled drug release performances. The as-released UA drugs from the scaffolds increased remarkably the alkaline phosphatase activity, osteogenic differentiation related gene type I collagen, runt-related transcription factor 2 expression, and osteoblast-associated protein expression. Moreover, the results of micro-CT images, histomorphological observations demonstrated that the MBG/CS/UA scaffolds improved new bone formation ability. Therefore, the MBG/CS/UA porous scaffolds can be used as novel bone tissue engineering materials.


Asunto(s)
Regeneración Ósea/efectos de los fármacos , Cerámica/química , Quitosano/química , Sistemas de Liberación de Medicamentos , Andamios del Tejido/química , Triterpenos/farmacología , Animales , Línea Celular , Colágeno Tipo I/metabolismo , Subunidad alfa 1 del Factor de Unión al Sitio Principal/metabolismo , Liberación de Fármacos , Femenino , Humanos , Ratones , Microesferas , Oseointegración/efectos de los fármacos , Osteogénesis/efectos de los fármacos , Porosidad , Ratas Sprague-Dawley , Ácido Ursólico
11.
J Arthroplasty ; 33(3): 794-799, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29269273

RESUMEN

BACKGROUND: A number of methods for reduction in high hip dislocation in total hip arthroplasty (THA) are time-consuming and laborious, and require great surgical skills. This study aimed to introduce a new reduction technique to achieve rapid, safe, and easy reduction in high hip dislocation. METHODS: We retrospectively reviewed 74 THA patients (82 hips; 44 women, 30 men) with severe hip dysplasia who underwent direct leverage using a Hohmann retractor into the anatomical acetabulum without femoral shortening osteotomy between September 2007 and January 2014. Forty-nine hips were classified as Crowe III and 33 hips were classified as Crowe IV. The mean follow-up period was 5.1 years (range 2-8). RESULTS: Mean Harris Hip Score increased from 42.1 (range 24-71) before surgery to 89.9 (range 76-100) at final follow-up examination. The legs were lengthened by a mean of 3.0 cm (range 1.1-5.5) and 2.5 cm (range 1.1-3.5) in Crowe III hips and 3.6 cm (range 1.9-5.5) in Crowe IV hips postoperatively. The average leg-length discrepancy at the final follow-up examination was 0.4 cm (standard deviation 0.5 cm). One greater trochanteric fracture occurred during the hip reduction process. One patient developed femoral nerve palsies and recovered completely at 3 weeks postoperatively. CONCLUSION: Direct leverage using the Hohmann retractor for the reduction in high hip dislocation in THA without femoral shortening osteotomy is simple, safe, and effective.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/métodos , Cabeza Femoral/cirugía , Fémur/cirugía , Luxación Congénita de la Cadera/cirugía , Osteotomía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Luxación de la Cadera/cirugía , Fracturas de Cadera/cirugía , Humanos , Diferencia de Longitud de las Piernas/cirugía , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Procedimientos de Cirugía Plástica , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Adulto Joven
12.
J Arthroplasty ; 32(4): 1374-1380, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27956127

RESUMEN

BACKGROUND: Recommendations for minimum cup coverage based on anteroposterior radiographs are widely used as an intraoperative guide in total hip arthroplasty for patients with developmental dysplasia of the hip. The purpose of this study was to examine the validity of two-dimensional (2D) measurement of coverage with three-dimensional (3D) coverage and to identify parameters for determining the 3D coverage during surgery. METHODS: We developed a technique to accurately reproduce the intraoperative anatomic geometry of the dysplastic acetabulum and measure the 3D cup coverage postoperatively. With this technique, we retrospectively analyzed the difference and correlation between 2D and 3D measurements of native bone coverage in 35 patients (45 hips) with Crowe II or III DDH. Linear regression analysis was performed to examine the intraoperative parameters related to coverage. The mean follow-up period was 7.64 years (range, 6.1-9.5 years). RESULTS: There was a significant difference and a fair correlation between 2D and 3D measurements. The 2D measurement underestimated the 3D cup coverage by approximately 13%. An excellent linear relationship was noted between the 3D coverage/uncoverage and the height of the uncovered portion (R2 = 0.8440, P < .0001). There was no case of loosening or revision during the follow-up. CONCLUSION: Current minimum cup coverage recommendations based on 2D radiograph measurements should not be used as a direct intraoperative guide. The height of the uncovered portion is a useful parameter to determine the 3D coverage during surgery.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Luxación Congénita de la Cadera/cirugía , Articulación de la Cadera/diagnóstico por imagen , Imagenología Tridimensional/métodos , Tomografía Computarizada por Rayos X/métodos , Acetábulo/cirugía , Adolescente , Adulto , Anciano , Femenino , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Radiografía , Estudios Retrospectivos , Adulto Joven
13.
J Arthroplasty ; 32(3): 849-856, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27919583

RESUMEN

BACKGROUND: This study compares the outcome between THA with and without femoral shortening osteotomy for unilateral mild to moderate high hip dislocation in developmental dysplasia of the hip patients. METHODS: The data on 42 hips in 42 patients who had undergone THA for unilateral mild to moderate high hip dislocation were retrospectively reviewed after being prospectively collected. In 22 patients, hips were reduced by soft tissue release and direct leverage using an elevator, without the osteotomy. The remaining 20 patients were treated with a subtrochanteric transverse shortening osteotomy. The mean follow-up of patients was 5 years (standard deviation = 1.0) for the nonosteotomy group and 6.2 years (standard deviation = 1.6) for the osteotomy group. RESULTS: The Harris Hip Score significantly improved in both groups. In the nonosteotomy group, we observed a lower leg length discrepancy compared with the osteotomy group (0.4 cm and 2.2 cm, respectively). Four patients (18.2%) in the nonosteotomy group and 15 patients (75%) in the osteotomy group developed a limp (P < .0001). Three patients (13%) developed femoral nerve palsy in the nonosteotomy group, but they all recovered completely within 6 months after the surgery. Nineteen patients in the nonosteotomy group showed knee valgus deformity immediately after the surgery but only 4 cases in the osteotomy group. CONCLUSION: Compared with THA with femoral shortening osteotomy, THA without the osteotomy was associated with a lower number of patients who developed a limp at the end of follow-up; however, the rehabilitation was slower and more difficult, and a larger number of patients showed reversible nerve palsy and knee valgus deformity.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Luxación Congénita de la Cadera/cirugía , Adulto , Anciano , Femenino , Fémur/cirugía , Luxación de la Cadera/cirugía , Humanos , Articulación de la Rodilla , Diferencia de Longitud de las Piernas , Masculino , Persona de Mediana Edad , Osteotomía , Estudios Retrospectivos
14.
Clin Exp Rheumatol ; 34(5): 929-934, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27606839

RESUMEN

Subchondral bone has received increasing attention in both basic and clinical research on osteoarthritis (OA). Subchondral bone in OA presents abnormalities in structure, biochemical composition, biomechanics and cellular function. Overall, subchondral bone mainly shows bone resorption in early OA and bone formation in late OA. More and more evidence suggests that abnormalities in subchondral bone of OA promote joint pain generation and articular cartilage degeneration. Inhibition or amelioration of subchondral bone abnormalities can reduce joint pain and can delay cartilage degeneration; thus, subchondral bone-targeted treatment promises to be a new treatment approach for OA. The pathological changes and the role of subchondral bone in OA still require further investigation.


Asunto(s)
Artralgia/etiología , Remodelación Ósea , Cartílago Articular/patología , Articulaciones/patología , Osteoartritis/patología , Animales , Artralgia/patología , Artralgia/fisiopatología , Artralgia/prevención & control , Fenómenos Biomecánicos , Conservadores de la Densidad Ósea/uso terapéutico , Remodelación Ósea/efectos de los fármacos , Cartílago Articular/efectos de los fármacos , Cartílago Articular/fisiopatología , Humanos , Articulaciones/efectos de los fármacos , Articulaciones/fisiopatología , Osteoartritis/complicaciones , Osteoartritis/tratamiento farmacológico , Osteoartritis/fisiopatología , Factores de Riesgo
16.
Clin Orthop Relat Res ; 474(3): 731-40, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26467611

RESUMEN

BACKGROUND: Revision THA is particularly challenging in hips with severe acetabular bone loss. When the extent or geometry of the acetabular bone loss precludes more-straightforward techniques such as jumbo hemispheric cementless shells, reconstruction with morselized allograft protected by a custom cage may offer an alternative, but, to our knowledge, few series have reported on results with this approach. QUESTIONS/PURPOSES: For patients with severe (Paprosky IIIB) defects, we asked: do individualized custom cages result in (1) improved Harris hip scores; (2) restoration of hip center; and (3) a low incidence of surgical complications? METHODS: Twenty-six patients (26 hips) with a massive acetabular defect were involved in this study from 2003 to 2013. During this period, one patient was lost to followup and one died, leaving 24 patients (eight males, 16 females) in this retrospective analysis. The customized cages were individualized to each patient's bone defect based on rapid-prototype three-dimensional printed models. Mean followup was 67 months (range, 24-120 months). Harris hip scores were assessed before surgery and at each followup. Postoperative radiographs were evaluated for cage position, migration, and graft incorporation. Complications and reoperations were assessed by chart review. RESULTS: The mean Harris hip score improved from 36 (SD, 8; range, 20-49) to 82 (SD, 18; range, 60-96) (p < 0.001). Individualized custom cages resulted in generally reliable restoration of the hip center. No rerevisions have been performed. None of the cups showed radiographic migration, but one cage was believed to be loose, based on a circumferential 2-mm radiolucent line. Cancellous allografts appeared to be incorporated in 23 of 24 patients. One deep infection and one superficial infection were observed and treated with irrigation, débridement, and vacuum-sealing drainage. One dislocation and one suspected injury of the superior gluteal nerve also were observed and treated conservatively. CONCLUSIONS: Individualized custom cages using rapid prototyping and three-dimensional printing appeared to provide stable fixation and improved hip scores at short-term followup in this small, single-center series. As further improvements in the design and manufacturing process are made, future studies should evaluate larger patient groups for longer times, and, ideally, compare this approach with alternatives for these complex bone defects. LEVEL OF EVIDENCE: Level IV, therapeutic study.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Acetábulo/diagnóstico por imagen , Acetábulo/patología , Anciano , Evaluación de la Discapacidad , Femenino , Humanos , Fijadores Internos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/prevención & control , Impresión Tridimensional , Diseño de Prótesis , Reoperación , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
17.
J Arthroplasty ; 31(4): 850-6, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26681646

RESUMEN

PURPOSES: To examine the clinical outcomes of patients treated with a nickel-titanium shape-memory sawtooth-arm embracing clamp (Ni-Ti SSEC) in complex femoral revision surgery. METHODS: We retrospectively evaluated the outcomes for 21 complex femoral revision hip arthroplasties that we treated using an Ni-Ti SSEC. The Ni-Ti SSEC was used for various procedures, including the fixation of extremely long cortical windows (11 patients), femoral shaft osteotomy (4 patients), an extended trochanteric osteotomy (3 patients), and protection of a penetrated femoral cortex by a primary stem (3 patients). All patients received follow-up care for an average of 48.2 months. RESULTS: The mean time of Ni-Ti SSEC insertion intraoperatively was 6 minutes. The mean Harris Hip Score improved from 21.2 points before revision surgery to 83.1 points at the most recent examination. No implant failures or malunions occurred. Dislocation and deep infection occurred in 1 case during the follow-up period. CONCLUSIONS: Our results show that the embracing clamp is a simple and valid method for fixing osteotomies in treating complex femoral revision surgery.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Fémur/cirugía , Prótesis de Cadera , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Materiales Biocompatibles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Níquel , Osteotomía/instrumentación , Diseño de Prótesis , Reoperación , Estudios Retrospectivos , Titanio , Adulto Joven
18.
J Arthroplasty ; 31(6): 1233-1239, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26774406

RESUMEN

BACKGROUND: We sought to evaluate posterosuperior placement of the acetabular component at the true acetabulum during acetabular reconstruction in patients with Crowe type-IV developmental dysplasia of the hip. METHODS: Using pelvic computed tomography and image processing, we developed a two-dimensional mapping technique to demonstrate the distribution of preoperative three-dimensional cup coverage at the true acetabulum, determined the postoperative location of the acetabular cup, and calculated postoperative three-dimensional coverage for 16 Crowe type-IV dysplastic hips in 14 patients with a mean age of 52 years (33-78 years) who underwent total hip arthroplasty. Mean follow-up was 6.3 years (5.5-7.3 years). RESULTS: On preoperative mapping, the maximum three-dimensional coverage using a 44-mm cup was 87.31% (77.36%-98.14%). Mapping enabled the successful replacement of 16 hips using a mean cup size of 44.13 mm (42-46 mm) with posterosuperior placement of the cup. Early weight-bearing and no prosthesis revision or loosening during follow-up were achieved in all patients. The postoperative two-dimensional coverage on anteroposterior radiographs and three-dimensional coverage were 96.15% (89.49%-100%) and 83.42% (71.81%-98.50%), respectively. CONCLUSION: This technique may improve long-term implant survival in patients with Crowe-IV developmental dysplasia of the hip undergoing total hip arthroplasty by allowing the use of durable bearings, increasing host bone coverage, ensuring initial stability, and restoring the normal hip center.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/métodos , Luxación Congénita de la Cadera/cirugía , Luxación de la Cadera/cirugía , Acetábulo/diagnóstico por imagen , Adulto , Anciano , Cementos para Huesos , Cerámica , Femenino , Luxación de la Cadera/diagnóstico por imagen , Luxación Congénita de la Cadera/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Pelvis/diagnóstico por imagen , Pelvis/cirugía , Tomografía Computarizada por Rayos X
19.
J Arthroplasty ; 30(12): 2248-55, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26228491

RESUMEN

The combined anteversion surgical technique has been proposed and used in clinical practice. To more objectively evaluate the feasibility of this surgical technique using combined anteversion concept for DDH patients, we studied 34 DDH patients (40 hips) in this research. Every patient underwent pelvic CT scans before and after surgery and the HHSs were recorded. Optimal range of joint motion was measured using a three-dimensional reconstruction technique and a dynamic measurement technique. The results revealed that joint function met the requirements of daily life and the range of motion was not over-limited by impingement between the prosthesis and the skeleton. Moreover, the combined anteversion was found to be the most critical parameter in this study.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Luxación Congénita de la Cadera/cirugía , Articulación de la Cadera/fisiología , Rango del Movimiento Articular , Anciano , Femenino , Cadera/cirugía , Articulación de la Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Movimiento , Pelvis/diagnóstico por imagen , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
20.
Int Orthop ; 39(10): 2023-30, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26285669

RESUMEN

PURPOSE: Revision total hip arthroplasty (THA) is challenging if severe periacetabular bone loss is present. Here we describe a method that uses a customised cage to reconstruct an acetabulum with a massive bone defect. METHODS: Designed with the aid of the rapid prototyping technique, a customised cage with a hook, crest and flange or braids was made, and then utilized to reconstruct severe compromised acetabulum in revision THA since 2001. Twenty-two patients (23 hips) were included in this study. The mean patient age at the time of surgery was 60.9 years (range, 38-80 years). Three hips had massive acetabular bone defects of Paprosky type IIIA and 20 of type IIIB. The Harris hip score was used to evaluate hip function. Radiographs were taken to evaluate loosening of the cage and resorption of allograft bone. RESULTS: The average follow up was 81.6 ± 24.9 months. The mean Harris hip score improved from 39.6 pre-operatively to 80.9 at the final follow-up. There were no instances of deep infection, severe venous thrombosis, and nerve palsy. One patient who had an intra-operative rupture of the superior acetabular artery was successfully treated using the haemostatic suturing technique. Two patients experienced dislocation at post-operative days four and six, respectively, and both were treated with closed reduction and skin traction for three weeks. CONCLUSIONS: The present study demonstrates that a customised cage may be a promising option for THA revision of severely compromised acetabula. Extended follow-up is necessary to evaluate the long-term performance of this approach.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/instrumentación , Resorción Ósea/cirugía , Articulación de la Cadera/cirugía , Artropatías/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/métodos , Trasplante Óseo , Femenino , Prótesis de Cadera , Humanos , Masculino , Persona de Mediana Edad , Impresión Tridimensional , Cintigrafía , Reoperación , Cirugía Asistida por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA