Clin Biochem ; 43(4-5): 473-82, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19896933

RESUMEN

OBJECTIVES: An accurate and precise high-performance liquid chromatographic method using diode array detection for the determination of levetiracetam in human plasma has been developed and validated for use in pharmacokinetic studies. METHODS: A harmonized validation strategy based on the accuracy profiles was used to select the most appropriate regression model and to determine the limits of quantitation as well as the concentration range of the developed analytical procedure. On the other hand, the present paper also shows this validation approach as a suitable tool to guaranty the quality of the results obtained by the use of the analytical validated methodology for plasma levetiracetam determination in a routine setting and to ensure the risk of obtaining the future measurements outside the previously fixed acceptance limits. RESULTS: As pointed recently, the FDA, a weighted 1/x(2) quadratic regression model ranging from 0.53 to 107.00 mg/L was selected as the simplest calibration model that maximized the accuracy all over the range. Relative bias was <5%, assay imprecision was always <6% and mean extraction recovery from plasma was >90%. So, accuracy did not exceed the acceptance limits settled at + or - 20% according to the FDA or Washington conference regulatory requirements for bioanalytical methods. Internal quality control has been assessed over a 2 year time period. All controls were essentially found to provide levetiracetam concentrations within the target range according to the FDA. CONCLUSIONS: The validated analytical procedure complies with strongest regulatory standards. The validated method has a sufficiently rapid turnaround time and their results are good enough to enable the laboratory to routinely provide useful and accurate pharmacokinetic data in time to adjust patient regimens.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Monitoreo de Drogas/métodos , Piracetam/análogos & derivados , Estudios de Validación como Asunto , Humanos , Levetiracetam , Límite de Detección , Modelos Lineales , Piracetam/sangre , Control de Calidad , Factores de Riesgo
2.
Biol Blood Marrow Transplant ; 13(11): 1324-37, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17950919

RESUMEN

The purpose of this trial was to define the maximum tolerated duration (MTD), dose-limiting toxicity (DLT), regimen-related toxicities (RRT), and pharmacokinetics of gemcitabine infused at a fixed dose rate (FDR) of 10 mg/m2/min, combined with docetaxel/melphalan/carboplatin, using autologous stem cell transplantation (ASCT). The duration of gemcitabine infusion was incrementally escalated as a single treatment on day -6 or as 4 daily infusions on days -5 to -2. Gemcitabine was followed by docetaxel (300 or 350 mg/m2) on day -5, and then melphalan (50 mg/m2/day) and carboplatin (333 mg/m2/day) on days -4 to -2. Fifty-two patients with refractory tumors were accrued with a median age of 40 (range: 6-66), a median of 3 (1-6) prior chemotherapy regimens, and 3 (1-7) organs involved. The gemcitabine MTD was defined at 20 hours (total dose 12,000 mg/m2) on both schedules. The DLT was enteritis. Three patients died from aspiration, catheter-related sepsis, and enteritis, respectively. The tumor response rate was 91%, with 50% complete responses. At current 2-year median follow-up, the event-free and overall survival (EFS, OS) rates are 54% (median 26 months) and 79% (median not reached), respectively. Gemcitabine area under the curve (AUC), but not clearance, increased linearly with infusion duration, and correlated with grade 3 RRT. Docetaxel showed a linear increase of its AUC and similar clearance compared with prior reports at lower doses. In conclusion, ASCT-supported infusions of gemcitabine at FDR could be prolonged up to 20 hours. The resulting gemcitabine/docetaxel/melphalan/carboplatin combination was highly active in refractory cancers and should be further tested in disease-specific trials.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Desoxicitidina/análogos & derivados , Trasplante de Células Madre Hematopoyéticas/métodos , Trasplante Autólogo/métodos , Adolescente , Adulto , Anciano , Carboplatino/administración & dosificación , Niño , Desoxicitidina/administración & dosificación , Desoxicitidina/farmacocinética , Supervivencia sin Enfermedad , Docetaxel , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Masculino , Dosis Máxima Tolerada , Melfalán/administración & dosificación , Persona de Mediana Edad , Neoplasias/tratamiento farmacológico , Taxoides/administración & dosificación , Gemcitabina
3.
Ther Drug Monit ; 25(2): 221-8, 2003 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-12657918

RESUMEN

Tegafur, a prodrug of 5-fluorouracil (5-FU), is an oral fluorouracil antitumor drug used for the management of adenocarcinomas. It has an efficacy similar to that of intravenous 5-FU, with potential advantages in terms of convenience and quality of life for the patient and cost-effectiveness as compared with intravenous chemotherapy. The authors developed a high-performance liquid chromatography (HPLC) assay for the determination of tissue or plasma tegafur and 5-FU concentration in a single step extraction and a single HPLC injection. The retention times of 5-FU and tegafur were 5 and 16.5 minutes, respectively, and the internal standard retention times were 11.5 and 17.5 minutes for 5-bromouracil (5-BU) and beta-hydroxyethyltheophylline, respectively. The limit of quantification was 0.0125 microg/mL for 5-FU and 0.05 microg/mL for tegafur. The assay had good recovery (96.5% +/- 9.45% and 97.5% +/- 7.89% for 5-FU in plasma and tissue, respectively, and 88.5% +/- 12.17% and 104.9% +/- 8.77% for tegafur in plasma and tissue, respectively). Precision was good: the within-day and between-day standard deviation of the mean (RSD) for 5-FU (0.0125-5 microg/mL) and tegafur (0.5-150 microg/mL) was always <8%. The authors conclude that the method described here is ideally suited for the therapeutic monitoring of 5-FU and tegafur.


Asunto(s)
Antimetabolitos Antineoplásicos/sangre , Fluorouracilo/análisis , Profármacos/metabolismo , Tegafur/análisis , Cromatografía Líquida de Alta Presión/métodos , Fluorouracilo/sangre , Humanos , Tegafur/sangre , Distribución Tisular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA