Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Acta Clin Croat ; 58(Suppl 2): 24-35, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34975195

RESUMEN

Prostate cancer is one of the most important men's health issues in developed countries. For patients with prostate cancer a preoperative staging of the disease must be made. Involvement of lymph nodes could be assessed using imaging methods (CT or/and MRI), however, newer methods also exist (PET/CT, PSMA PET/CT). For some patients during radical prostatectomy a pelvic lymphadenectomy is recommended. Pelvic lymphadenectomy is indicated in intermediate- and high-risk group patients and with increased probability of lymph node invasion. The most used prediction tools for preoperative assessment of lymph nodes are Briganti and MSKCC nomograms and Partin tables. Pelvic lymphadenectomy can include different lymph nodes group, but extended lymphadenectomy is the recommended procedure. In 1-20% of patients, the lymph node invasion is present. Pelvic lymphadenectomy is primarily a diagnostic and staging method, and in minority of patients with positive lymph nodes it can be a curative method, too. In other patients with positive lymph nodes adjuvant therapy (radiotherapy and androgen deprivation therapy) can be beneficial.

2.
Diagnostics (Basel) ; 14(2)2024 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-38248025

RESUMEN

The aim of our study was to establish and compare the diagnostic accuracy and clinical applicability of published chest CT severity scoring systems used for COVID-19 pneumonia assessment and to propose the most efficient CT scoring system with the highest diagnostic performance and the most accurate prediction of disease severity. This retrospective study included 218 patients with PCR-confirmed SARS-CoV-2 infection and chest CT. Two radiologists blindly evaluated CT scans and calculated nine different CT severity scores (CT SSs). The diagnostic validity of CT SSs was tested by ROC analysis. Interobserver agreement was excellent (intraclass correlation coefficient: 0.982-0.995). The predominance of either consolidations or a combination of consolidations and ground-glass opacities (GGOs) was a predictor of more severe disease (both p < 0.005), while GGO prevalence alone was not. Correlation between all CT SSs was high, ranging from 0.848 to 0.971. CT SS 30 had the highest diagnostic accuracy (AUC = 0.805) in discriminating mild from severe COVID-19 disease compared to all the other proposed scoring systems (AUC range 0.755-0.788). In conclusion, CT SS 30 achieved the highest diagnostic accuracy in predicting the severity of COVID-19 disease while maintaining simplicity, reproducibility, and applicability in complex clinical settings.

3.
Sci Rep ; 14(1): 13605, 2024 06 13.
Artículo en Inglés | MEDLINE | ID: mdl-38871772

RESUMEN

The aim of this study was to characterize the systemic cytokine signature of critically ill COVID-19 patients in a high mortality setting aiming to identify biomarkers of severity, and to explore their associations with viral loads and clinical characteristics. We studied two COVID-19 critically ill patient cohorts from a referral centre located in Central Europe. The cohorts were recruited during the pre-alpha/alpha (November 2020 to April 2021) and delta (end of 2021) period respectively. We determined both the serum and bronchoalveolar SARS-CoV-2 viral load and identified the variant of concern (VoC) involved. Using a cytokine multiplex assay, we quantified systemic cytokine concentrations and analyzed their relationship with clinical findings, routine laboratory workup and pulmonary function data obtained during the ICU stay. Patients who did not survive had a significantly higher systemic and pulmonary viral load. Patients infected with the pre-alpha VoC showed a significantly lower viral load in comparison to those infected with the alpha- and delta-variants. Levels of systemic CTACK, M-CSF and IL-18 were significantly higher in non-survivors in comparison to survivors. CTACK correlated directly with APACHE II scores. We observed differences in lung compliance and the association between cytokine levels and pulmonary function, dependent on the VoC identified. An intra-cytokine analysis revealed a loss of correlation in the non-survival group in comparison to survivors in both cohorts. Critically ill COVID-19 patients exhibited a distinct systemic cytokine profile based on their survival outcomes. CTACK, M-CSF and IL-18 were identified as mortality-associated analytes independently of the VoC involved. The Intra-cytokine correlation analysis suggested the potential role of a dysregulated systemic network of inflammatory mediators in severe COVID-19 mortality.


Asunto(s)
COVID-19 , Enfermedad Crítica , Citocinas , Unidades de Cuidados Intensivos , SARS-CoV-2 , Humanos , COVID-19/mortalidad , COVID-19/sangre , Citocinas/sangre , Masculino , Persona de Mediana Edad , Femenino , Anciano , Carga Viral , Biomarcadores/sangre , Estudios de Cohortes , Pandemias
4.
Br J Radiol ; 95(1139): 20220394, 2022 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-36116132

RESUMEN

OBJECTIVES: Computerized tomography (CT) is the most accurate method for evaluating pelvic calcifications, which are of utmost importance for planning kidney transplantation (KT). The aim of our study was to evaluate the incidence and distribution of iliac artery calcifications and correlate the novel pelvic calcification score (PCS) with cardiovascular risk factors and graft and overall survival in KT patients. METHODS: We retrospectively included 118 KT patients operated at our institution with pretransplant pelvic CT. Calcification morphology, circumference and length of both common and external iliac arteries were independently scored by two uroradiologists. PCS was calculated as the total score sum of all three calcification features in all vessels. PCS correlation with graft and patient survival was performed. RESULTS: Calcification in at least one vascular segment was found in 79% of patients. PCS was significantly higher in male patients (p = 0.006), patients over 55 years (p < 0.001), and patients on haemodialysis (p = 0.016). Patients with a PCS >3 had significantly shorter graft and overall survival rates (p = 0.041 and p = 0.039, respectively). CONCLUSIONS: The extent of iliac artery calcification in KT recipients quantified by PCS on pretransplant CT correlates with graft and overall patient survival. A PCS over three was associated with worse clinical outcomes and could become a possible prognostic factor. ADVANCES IN KNOWLEDGE: Our novel PCS is a robust method for quantifying iliac artery calcification burden. Since higher a PCS correlates with worse patient and graft survival, PCS has the potential to become a prognostic factor in kidney transplant patients.


Asunto(s)
Trasplante de Riñón , Calcificación Vascular , Humanos , Masculino , Trasplante de Riñón/efectos adversos , Trasplante de Riñón/métodos , Estudios Retrospectivos , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/complicaciones , Supervivencia de Injerto , Tomografía Computarizada por Rayos X/efectos adversos , Factores de Riesgo
5.
Br J Radiol ; 94(1121): 20210013, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33861140

RESUMEN

OBJECTIVES: Studies show insufficient sensitivity of virtual non-contrast (VNC) reconstructions for stone detection in dual-energy CT urography (DE-CTU). The aim of this study was to investigate if side-by-side-evaluation of both VNC and post-contrast images could increase the sensitivity of single-phase split bolus DE-CTU. METHODS: Consecutive patients with haematuria who underwent split bolus DE-CTU on the same dual-source DE-CT scanner were retrospectively enrolled in the study. Intravenous furosemide and oral hydration were employed. Two readers, independently and then jointly in two separate sessions, recorded the location and the longest axial stone diameter on three randomised sets of images: separate VNC and post-contrast images, and side-by-side-reconstructions. True non-contrast (TNC) images served as the standard of reference. RESULTS: A total of 83 urinary stones were detected on TNC images. Independent reader side-by-side-evaluation of VNC and post-contrast images yielded higher stone detection sensitivity (76 and 84%, respectively) compared to evaluation of only VNC (71 and 81%, respectively) or post-contrast images (64 and 80%, respectively). The sensitivity of joint reader evaluation of side-by-side-images reached almost 86% and was not significantly different from TNC images (p = 0.77). All stones larger than 3 mm were correctly detected by side-by-side-evaluation. Dose reduction of 55% could be achieved by omitting TNC scans. CONCLUSION: Side-by-side-VNC and post-contrast image evaluation enable detection of clinically significant urolithiasis on single-phase split bolus DE-CTU with significant dose reduction. ADVANCES IN KNOWLEDGE: This study shows that single-phase DE-CTU is feasible if VNC imaging is simultaneously utilised with post-contrast images.


Asunto(s)
Medios de Contraste , Tomografía Computarizada por Rayos X/métodos , Urografía/métodos , Urolitiasis/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Hematuria/etiología , Humanos , Cálculos Renales/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Dosis de Radiación , Estudios Retrospectivos , Sensibilidad y Especificidad , Cálculos Ureterales/diagnóstico por imagen , Cálculos de la Vejiga Urinaria/diagnóstico por imagen , Urolitiasis/complicaciones
6.
Neuroradiol J ; 33(3): 259-266, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32314666

RESUMEN

PURPOSE: Weighted average dual-energy computed tomography (DE-CT) reconstructions are considered a proxy of standard CT images of the brain, recommended for routine clinical use and used as a reference standard in DE-CT research. However, their image quality has not been assessed, which was the aim of our study. METHODS: Images from 81 consecutive patients who underwent both non-contrast single-energy (SE)-CT and DE-CT of the brain on the same scanner were retrospectively evaluated. Attenuation values (HU) and SD of grey matter/white matter (GM/WM) pairs, along with SD in the posterior fossa and subcalvarial region were measured. Four readers evaluated image noise, GM/WM contrast, posterior fossa and subcalvarial artefacts, as well as overall image quality. RESULTS: Weighted average DE-CT GM and WM HU were significantly lower and noise higher compared to SE-CT (GM HU 36.46 v. 41.82; WM HU 28.18 v. 29.94; GM SD 2.93 v. 2.49; and WM SD 3.16 v. 2.44, all p < 0.0001). After correcting the measured SE-CT noise for 37% higher acquisition dose, DE-CT GM noise became significantly lower (2.93 v. 3.11, p = 0.0121). Measured and dose corrected SE-CT GM/WM contrast-to-noise ratio was superior to weighted average DE-CT (3.42 and 2.74 v. 1.95, both p < 0.0001). Weighted average DE-CT had significantly less artifacts on qualitative analysis. CONCLUSION: Weighted average DE-CT images of the brain yield less artefacts at 37% dose reduction and lower noise at SE-CT equivalent dose. Dose-adjusted GM/WM contrast-to-noise ratio of weighted average DE-CT with 0.4 weighting factor remains inferior to SE-CT images.


Asunto(s)
Encéfalo/diagnóstico por imagen , Neuroimagen/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
7.
Coll Antropol ; 32 Suppl 2: 45-6, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19138005

RESUMEN

During 3-year study of 73 patients with dental inflammation, sinusitis, otitis and 5 cases with granuloma, in 9 cases we observed the development of central retinitis. All patients were medicated with the same antibiotics and parabulbar depo of Prednisolonacetate. To 50% of these patients, we suggested eye protection with Yellow Medical filters during two months. In the first group with medication we observed better vision in 69%, but in the second group with eye protection with Yellow Medical filters we observed normalization of vision in 100%.


Asunto(s)
Antibacterianos/efectos adversos , Dispositivos de Protección de los Ojos , Fotofobia/inducido químicamente , Prednisolona/análogos & derivados , Retinitis/etiología , Enfermedades Dentales/tratamiento farmacológico , Humanos , Inflamación , Edema Macular/etiología , Edema Macular/prevención & control , Fotofobia/prevención & control , Prednisolona/efectos adversos , Retinitis/prevención & control , Enfermedades Dentales/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA