Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Hum Brain Mapp ; 39(9): 3558-3573, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29693304

RESUMEN

Slow sinusoidal, hemodynamic oscillations (SSHOs) around 0.1 Hz are frequently seen in mammalian and human brains. In four patients undergoing epilepsy surgery, subtle but robust fluctuations in oxy- and deoxyhemoglobin were detected using hyperspectral imaging of the cortex. These SSHOs were stationary during the entire 4 to 10 min acquisition time. By Fourier filtering the oxy- and deoxyhemoglobin time signals with a small bandwidth, SSHOs became visible within localized regions of the brain, with distinctive frequencies and a continuous phase variation within that region. SSHOs of deoxyhemoglobin appeared to have an opposite phase and 11% smaller amplitude with respect to the oxyhemoglobin SSHOs. Although the origin of SSHOs remains unclear, we find indications that the observed SSHOs may embody a local propagating hemodynamic wave with velocities in line with capillary blood velocities, and conceivably related to vasomotion and maintenance of adequate tissue perfusion. Hyperspectral imaging of the human cortex during surgery allow in-depth characterization of SSHOs, and may give further insight in the nature and potential (clinical) use of SSHOs.


Asunto(s)
Ondas Encefálicas/fisiología , Corteza Cerebral/fisiopatología , Circulación Cerebrovascular , Epilepsia/fisiopatología , Hemoglobinometría/métodos , Hemoglobinas/análisis , Oxihemoglobinas/análisis , Espectrofotometría/métodos , Adolescente , Corteza Cerebral/irrigación sanguínea , Epilepsia/cirugía , Femenino , Análisis de Fourier , Neuroimagen Funcional/métodos , Hemoglobinometría/instrumentación , Humanos , Procesamiento de Imagen Asistido por Computador , Periodo Intraoperatorio , Masculino , Espectrofotometría/instrumentación , Adulto Joven
2.
NMR Biomed ; 29(9): 1295-304, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-25916399

RESUMEN

Thus far, blood flow velocity measurements with MRI have only been feasible in large cerebral blood vessels. High-field-strength MRI may now permit velocity measurements in much smaller arteries. The aim of this proof of principle study was to measure the blood flow velocity and pulsatility of cerebral perforating arteries with 7-T MRI. A two-dimensional (2D), single-slice quantitative flow (Qflow) sequence was used to measure blood flow velocities during the cardiac cycle in perforating arteries in the basal ganglia (BG) and semioval centre (CSO), from which a mean normalised pulsatility index (PI) per region was calculated (n = 6 human subjects, aged 23-29 years). The precision of the measurements was determined by repeated imaging and performance of a Bland-Altman analysis, and confounding effects of partial volume and noise on the measurements were simulated. The median number of arteries included was 14 in CSO and 19 in BG. In CSO, the average velocity per volunteer was in the range 0.5-1.0 cm/s and PI was 0.24-0.39. In BG, the average velocity was in the range 3.9-5.1 cm/s and PI was 0.51-0.62. Between repeated scans, the precision of the average, maximum and minimum velocity per vessel decreased with the size of the arteries, and was relatively low in CSO and BG compared with the M1 segment of the middle cerebral artery. The precision of PI per region was comparable with that of M1. The simulations proved that velocities can be measured in vessels with a diameter of more than 80 µm, but are underestimated as a result of partial volume effects, whilst pulsatility is overestimated. Blood flow velocity and pulsatility in cerebral perforating arteries have been measured directly in vivo for the first time, with moderate to good precision. This may be an interesting metric for the study of haemodynamic changes in aging and cerebral small vessel disease. © 2015 The Authors NMR in Biomedicine Published by John Wiley & Sons Ltd.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Angiografía Cerebral/métodos , Arterias Cerebrales/fisiología , Circulación Cerebrovascular/fisiología , Aumento de la Imagen/métodos , Angiografía por Resonancia Magnética/métodos , Flujo Pulsátil/fisiología , Adulto , Arterias Cerebrales/anatomía & histología , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Campos Magnéticos , Masculino , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Mult Scler ; 21(2): 155-62, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25013150

RESUMEN

BACKGROUND: Virchow-Robin spaces (VRS) are associated with vascular and neurodegenerative disease. In multiple sclerosis (MS), VRS have been associated with neuroinflammation. Ultra-high field imaging may be used to gain insight in these contradictory findings. OBJECTIVE: The objective of this paper is to analyze VRS in MS patients using high-resolution 7 Tesla (T) MRI. Additionally, we investigated whether the widening of VRS is related to inflammatory or neurodegenerative aspects of MS. METHODS: Thirty-four MS patients and 11 healthy controls were examined at 7T. Number and size of VRS were measured on three-dimensional (3D) T1-weighted images, and 3D fluid-attenuated inversion recovery (FLAIR) images were used for MS lesion detection. Brain atrophy was quantified by computing supratentorial brain volume fraction (sBVF). VRS counts were correlated with clinical variables, lesion count and sBVF. RESULTS: MS patients displayed more VRS (median 11) than healthy controls (median four), p = 0.001. VRS size did not differ between both groups. VRS count in MS patients was associated with sBVF (rho = -0.40, p = 0.02), but not with lesion count (p = 0.22). CONCLUSIONS: The 7T MRI reveals increased numbers of VRS in MS. The finding that VRS are associated with supratentorial brain atrophy, but not with lesion count, suggests that VRS might rather serve as a neurodegenerative than an inflammatory marker in MS.


Asunto(s)
Encéfalo/patología , Imagen por Resonancia Magnética/métodos , Esclerosis Múltiple/patología , Enfermedades Neurodegenerativas/patología , Adulto , Atrofia/patología , Biomarcadores , Femenino , Humanos , Imagen por Resonancia Magnética/instrumentación , Masculino , Persona de Mediana Edad , Esclerosis Múltiple/diagnóstico , Enfermedades Neurodegenerativas/diagnóstico
4.
Artículo en Inglés | MEDLINE | ID: mdl-38991775

RESUMEN

BACKGROUND AND PURPOSE: Prediction of aneurysm instability is crucial to guide treatment decisions and to select appropriate patients with unruptured intracranial aneurysms (IAs) for preventive treatment. High resolution four-dimensional magnetic resonance (4D MRI) flow imaging and 3D quantification of aneurysm morphology could offer insights and new imaging markers for aneurysm instability. In this cross-sectional study, we aim to identify 4D MRI flow imaging markers for aneurysm instability by relating hemodynamics in the aneurysm sac to 3D morphological proxy parameters for aneurysm instability. MATERIALS AND METHODS: In 35 patients with 37 unruptured IAs, a 3T MRA and a 7T 4D flow MRI scan was performed. Five hemodynamic parameters -peak-systolic (WSSMAX) and time-averaged wall shear stress (WSSMEAN), oscillatory shear index (OSI), mean velocity, and velocity pulsatility index (vPI)-were correlated to six 3D morphology proxy parameters of aneurysm instability -major axis length, volume, surface area (all three size parameters), flatness, shape index, and curvedness -by Pearson's correlation with 95% confidence intervals (CI). Scatterplots of hemodynamic parameters that correlated with IA size (major axis length) were created. RESULTS: WSSMAX and WSSMEAN correlated negatively with all three size parameters (strongest for WSSMEAN with volume (r = -0.70, 95% CI -0.83 to -0.49)) and OSI positively (strongest with major axis length (r = 0.87, 95% CI 0.76 to 0.93)). WSSMAX and WSSMEAN correlated positively with shape index (r = 0.61, 95% CI 0.36 to 0.78 and r = 0.49, 95% CI 0.20 to 0.70, respectively) and OSI negatively (r = 0.82, 95% CI -0.9 to -0.68). WSSMEAN and mean velocity correlated negatively with flatness (r = -0.35, 95% CI -0.61 to -0.029 and r = 0.33, 95% CI -0.59 to 0.007, respectively) and OSI positively (r = 0.54, 95% CI 0.26 to 0.74). vPI did not show any statistically significant correlation. CONCLUSIONS: Out of the five included hemodynamic parameters, WSSMAX, WSSMEAN, and OSI showed the strongest correlation with morphological 3D proxy parameters of aneurysm instability. Future studies should assess these promising new imaging marker parameters for predicting aneurysm instability in longitudinal cohorts of IA patients. ABBREVIATIONS: IA = intracranial aneurysm; 3D = three dimensional; 4D MRI flow = four-dimensional Magnetic Resonance Imaging flow; TOF-MRA = Time-of-flight Magnetic Resonance Angiography; WSS = wall shear stress; WSSMAX = WSS calculated at peak systole; WSSMEAN = time averaged WSS; OSI = oscillatory shear index; vPI = velocity pulsatility index.

5.
AJNR Am J Neuroradiol ; 45(4): 386-392, 2024 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-38548304

RESUMEN

BACKGROUND AND PURPOSE: Carotid siphon calcification might contribute to the high prevalence of cerebrovascular disease in pseudoxanthoma elasticum through increased arterial flow pulsatility. This study aimed to compare intracranial artery flow pulsatility, brain volumes, and small-vessel disease markers between patients with pseudoxanthoma elasticum and controls and the association between arterial calcification and pulsatility in pseudoxanthoma elasticum. MATERIALS AND METHODS: Fifty patients with pseudoxanthoma elasticum and 40 age- and sex-matched controls underwent 3T MR imaging, including 2D phase-contrast acquisitions for flow pulsatility in the assessment of ICA and MCA and FLAIR acquisitions for brain volumes, white matter lesions, and infarctions. All patients with pseudoxanthoma elasticum underwent CT scanning to measure siphon calcification. Flow pulsatility (2D phase-contrast), brain volumes, white matter lesions, and infarctions (3D T1 and 3D T2 FLAIR) were compared between patients and controls. The association between siphon calcification and pulsatility in pseudoxanthoma elasticum was tested with linear regression models. RESULTS: Patients with pseudoxanthoma elasticum (mean age, 57 [SD, 12] years; 24 men) had significantly higher pulsatility indexes (1.05; range, 0.94-1.21 versus 0.94; range, 0.82-1.04; P = .02), lower mean GM volumes (597 [SD, 53] mL versus 632 [SD, 53] mL; P < .01), more white matter lesions (2.6; range, 0.5-7.5 versus 1.1; range, 0.5-2.4) mL; P = .05), and more lacunar infarctions (64 versus 8, P = .04) than controls (mean age, 58 [SD, 11] years; 20 men). Carotid siphon calcification was associated with higher pulsatility indexes in patients with pseudoxanthoma elasticum (ß = 0.10; 95% CI, 0.01-0.18). CONCLUSIONS: Patients with pseudoxanthoma elasticum have increased intracranial artery flow pulsatility and measures of small-vessel disease. Carotid siphon calcification might underlie the high prevalence of cerebrovascular disease in pseudoxanthoma elasticum.


Asunto(s)
Lesiones Encefálicas , Calcinosis , Trastornos Cerebrovasculares , Seudoxantoma Elástico , Masculino , Humanos , Persona de Mediana Edad , Seudoxantoma Elástico/complicaciones , Seudoxantoma Elástico/diagnóstico por imagen , Seudoxantoma Elástico/patología , Arteria Carótida Interna/patología , Trastornos Cerebrovasculares/diagnóstico por imagen , Trastornos Cerebrovasculares/complicaciones , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Infarto
6.
Magn Reson Med ; 69(3): 868-76, 2013 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-22618854

RESUMEN

The assessment of both geometry and hemodynamics of the intracranial arteries has important diagnostic value in internal carotid occlusion, sickle cell disease, and aneurysm development. Provided that signal to noise ratio (SNR) and resolution are high, these factors can be measured with time-resolved three-dimensional phase contrast MRI. However, within a given scan time duration, an increase in resolution causes a decrease in SNR and vice versa, hampering flow quantification and visualization. To study the benefits of higher SNR at 7 T, three-dimensional phase contrast MRI in the Circle of Willis was performed at 3 T and 7 T in five volunteers. Results showed that the SNR at 7 T was roughly 2.6 times higher than at 3 T. Therefore, segmentation of small vessels such as the anterior and posterior communicating arteries succeeded more frequently at 7 T. Direction of flow and smoothness of streamlines in the anterior and posterior communicating arteries were more pronounced at 7 T. Mean velocity magnitude values in the vessels of the Circle of Willis were higher at 3 T due to noise compared to 7 T. Likewise, areas of the vessels were lower at 3 T. In conclusion, the gain in SNR at 7 T compared to 3 T allows for improved flow visualization and quantification in intracranial arteries.


Asunto(s)
Algoritmos , Circulación Cerebrovascular/fisiología , Círculo Arterial Cerebral/fisiología , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Adulto , Velocidad del Flujo Sanguíneo/fisiología , Círculo Arterial Cerebral/anatomía & histología , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
7.
Magn Reson Med ; 69(4): 1186-93, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22760686

RESUMEN

A setup for 7T MRI of the carotid arteries in the neck was designed and constructed. Separate dedicated arrays were used for transmit and receive. For the transmit array, single-side adapted dipole antennas were mounted on a dielectric pillow, which was shown to serve as a leaky waveguide, efficiently distributing B1 into the neck. Risk assessment was performed by simulations. Phantom measurements were performed to establish optimal positions of the antennas on the pillow. Using two antennas, a dual transmit setup was created. In vivo B1 (+) maps with different shim configurations were acquired to assess transmit performance. This effective transmit array was used in combination with a dedicated 30 channel small element receive coil. High-resolution in vivo turbo spin echo images were acquired to demonstrate the excellent performance of the setup.


Asunto(s)
Arterias Carótidas/anatomía & histología , Aumento de la Imagen/instrumentación , Angiografía por Resonancia Magnética/instrumentación , Transductores , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Neuroimage ; 61(4): 1043-9, 2012 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-22440643

RESUMEN

Animal and human autopsy studies suggest that subfields of the hippocampal formation are differentially affected by neuropsychiatric diseases. Therefore, subfield volumes may be more sensitive to effects of disease processes. The few human studies that segmented subfields of the hippocampal formation in vivo either assessed the subfields only in the body of the hippocampus, assessed only three subfields, or did not take the differential angulation of the head of the hippocampus into account. We developed a protocol using 7 Tesla MRI with isotropic voxels to reliably delineate the entorhinal cortex (ERC), subiculum (SUB), CA1, CA2, CA3, dentate gyrus (DG)&CA4 along the full-length of the hippocampus. Fourteen subjects (aged 54-74 years, 2 men and 12 women) were scanned with a 3D turbo spin echo (TSE) sequence with isotropic voxels of 0.7 × 0.7 × 0.7 mm(3) on a 7 T MRI whole body scanner. Based on previous protocols and extensive anatomic atlases, a new protocol for segmentation of subfields of the hippocampal formation was formulated. ERC, SUB, CA1, CA2, CA3 and DG&CA4 were manually segmented twice by one rater from coronal MR images. Good-to-excellent consistency was found for all subfields (Intraclass Correlation Coefficient's (ICC) varying from 0.74 to 0.98). Accuracy as measured with the Dice Similarity Index (DSI) was above 0.82 for all subfields, with the exception of the smaller subfield CA3 (0.68-0.70). In conclusion, this study shows that it is possible to delineate the main subfields of the hippocampal formation along its full-length in vivo at 7 T MRI. Our data give evidence that this can be done in a reliable manner. Segmentation of subfields in the full-length of the hippocampus may bolster the study of the etiology neuropsychiatric diseases.


Asunto(s)
Hipocampo/anatomía & histología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
9.
ScientificWorldJournal ; 2012: 691095, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22792049

RESUMEN

PURPOSE: To study the anatomy of the pterygopalatine fossa (PPF) using ultrahigh-resolution magnetic resonance imaging. METHODS: A human cadaveric tissue block containing the pterygopalatine fossa was examined on a clinical 7-Tesla magnetic resonance imaging system. Subsequently, cryosections of the tissue block were created in a coronal plane. The cryosections were photographed and collected on adhesive tape. The on-tape sections were stained for Mallory-Cason, in order to detail the anatomic structures within the fossa. Magnetic resonance images were compared with surface photos of the tissue block and on-tape sections. RESULTS: High-resolution magnetic resonance images demonstrated the common macroscopic structures in the PPF. Smaller structures, best viewed at the level of the operation microscope, which have previously been obscured on magnetic resonance imaging, could be depicted. Some of the orbital pterygopalatine ganglion branches and the pharyngeal nerve were clearly viewed. CONCLUSIONS: In our experience with one human cadaver specimen, magnetic resonance imaging at 7 Tesla seems effective in depicting pterygopalatine fossa anatomy and provides previously unseen details through its demonstration of the pharyngeal nerve and the orbital pterygopalatine ganglion branches. The true viability of depicting the pterygopalatine fossa with ultrahigh-resolution MR will depend on confirmation of our results in larger studies.


Asunto(s)
Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Fosa Pterigopalatina/anatomía & histología , Fosa Pterigopalatina/citología , Anciano , Cadáver , Humanos , Sistema Internacional de Unidades , Masculino
10.
Phys Fluids (1994) ; 34(12): 121909, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36776539

RESUMEN

Atrial fibrillation (AF) is the most common cardiac arrhythmia, inducing irregular and faster heart beating. Aside from disabling symptoms-such as palpitations, chest discomfort, and reduced exercise capacity-there is growing evidence that AF increases the risk of dementia and cognitive decline, even in the absence of clinical strokes. Among the possible mechanisms, the alteration of deep cerebral hemodynamics during AF is one of the most fascinating and least investigated hypotheses. Lenticulostriate arteries (LSAs)-small perforating arteries perpendicularly departing from the anterior and middle cerebral arteries and supplying blood flow to basal ganglia-are especially involved in silent strokes and cerebral small vessel diseases, which are considered among the main vascular drivers of dementia. We propose for the first time a computational fluid dynamics analysis to investigate the AF effects on the LSAs hemodynamics by using 7 T high-resolution magnetic resonance imaging (MRI). We explored different heart rates (HRs)-from 50 to 130 bpm-in sinus rhythm and AF, exploiting MRI data from a healthy young male and internal carotid artery data from validated 0D cardiovascular-cerebral modeling as inflow condition. Our results reveal that AF induces a marked reduction of wall shear stress and flow velocity fields. This study suggests that AF at higher HR leads to a more hazardous hemodynamic scenario by increasing the atheromatosis and thrombogenesis risks in the LSAs region.

11.
AJNR Am J Neuroradiol ; 43(4): 540-546, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35332021

RESUMEN

BACKGROUND AND PURPOSE: Cerebral small vessel disease contributes to stroke and cognitive impairment and interacts with Alzheimer disease pathology. Because of the small dimensions of the affected vessels, in vivo characterization of blood flow properties is challenging but important to unravel the underlying mechanisms of the disease. MATERIALS AND METHODS: A 2D phase-contrast sequence at 7T MR imaging was used to assess blood flow velocity and the pulsatility index of the perforating basal ganglia arteries. We included patients with cerebral amyloid angiopathy (n = 8; identified through the modified Boston criteria), hypertensive arteriopathy (n = 12; identified through the presence of strictly deep or mixed cerebral microbleeds), and age- and sex-matched controls (n = 28; no cerebral microbleeds). RESULTS: Older age was related to a greater pulsatility index, irrespective of cerebral small vessel disease. In hypertensive arteriopathy, there was an association between lower blood flow velocity of the basal ganglia and the presence of peri-basal ganglia WM hyperintensities. CONCLUSIONS: Our results suggest that age might be the driving factor for altered cerebral small vessel hemodynamics. Furthermore, this study puts cerebral small vessel disease downstream pathologies in the basal ganglia region in relation to blood flow characteristics of the basal ganglia microvasculature.


Asunto(s)
Angiopatía Amiloide Cerebral , Enfermedades de los Pequeños Vasos Cerebrales , Anciano , Arterias/patología , Ganglios Basales/patología , Angiopatía Amiloide Cerebral/complicaciones , Arterias Cerebrales/patología , Hemorragia Cerebral/complicaciones , Enfermedades de los Pequeños Vasos Cerebrales/complicaciones , Enfermedades de los Pequeños Vasos Cerebrales/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética
12.
Cereb Circ Cogn Behav ; 3: 100142, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36324395

RESUMEN

Perivascular spaces (PVS) are believed to be involved in brain waste disposal. PVS are associated with cerebral small vessel disease. At higher field strengths more PVS can be observed, challenging manual assessment. We developed a method to automatically detect and quantify PVS. A machine learning approach identified PVS in an automatically positioned ROI in the centrum semiovale (CSO), based on -resolution T2-weighted TSE scans. Next, 3D PVS tracking was performed in 50 subjects (mean age 62.9 years (range 27-78), 19 male), and quantitative measures were extracted. Maps of PVS density, length, and tortuosity were created. Manual PVS annotations were available to train and validate the automatic method. Good correlation was found between the automatic and manual PVS count: ICC (absolute/consistency) is 0.64/0.75, and Dice similarity coefficient (DSC) is 0.61. The automatic method counts fewer PVS than the manual count, because it ignores the smallest PVS (length <2 mm). For 20 subjects manual PVS annotations of a second observer were available. Compared with the correlation between the automatic and manual PVS, higher inter-observer ICC was observed (0.85/0.88), but DSC was lower (0.49 in 4 persons). Longer PVS are observed posterior in the CSO compared with anterior in the CSO. Higher PVS tortuosity are observed in the center of the CSO compared with the periphery of the CSO. Our fully automatic method can detect PVS in a 2D slab in the CSO, and extract quantitative PVS parameters by performing 3D tracking. This method enables automated quantitative analysis of PVS.

13.
Cereb Circ Cogn Behav ; 3: 100143, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36324413

RESUMEN

Patients with carotid occlusive disease express altered hemodynamics in the post-occlusive vasculature and lesions commonly attributed to cerebral small vessel disease (SVD). We addressed the question if cerebral perforating artery flow measures, using a novel 7T MRI technique, are altered and related to SVD lesion burden in patients with carotid occlusive disease. 21 patients were included with a uni- (18) or bilateral (3) carotid occlusion (64±7 years) and 19 controls (65±10 years). Mean flow velocity and pulsatility in the perforating arteries in the semi-oval center (CSO) and basal ganglia (BG), measured with a 2D phase contrast 7T MRI sequence, were compared between patients and controls, and between hemispheres in patients with unilateral carotid occlusive disease. In patients, relations were assessed between perforating artery flow measures and SVD burden score and white matter hyperintensity (WMH) volume. CSO perforating artery flow velocity was lower in patients than controls, albeit non-significant (mean difference [95% confidence interval] 0.08 cm/s [0.00-0.16]; p = 0.053), but pulsatility was similar (0.07  [-0.04-0.18]; p = 0.23). BG flow velocity and pulsatility did not differ between patients and controls (velocity = 0.28 cm/s [-0.32-0.88]; p = 0.34; pulsatility = 0.00 [-0.10-0.11]; p = 0.97). Patients with unilateral carotid occlusive disease showed no significant interhemispheric flow differences. Though non-significant, within patients lower CSO (p = 0.06) and BG (p = 0.11) flow velocity related to larger WMH volume. Our findings suggest that carotid occlusive disease may be associated with abnormal cerebral perforating artery flow and that this relates to SVD lesion burden in these patients, although our observations need corroboration in larger study populations.

15.
Eur Radiol ; 21(2): 310-7, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20694817

RESUMEN

OBJECTIVE: To characterize ex vivo healthy human axillary lymph nodes on 7 Tesla MRI and to correlate the findings with pathological analysis as a first step towards non-invasive staging of breast cancer patients in the future. METHODS: Four axillary lymph node dissection (ALND) specimens from 2 autopsy patients, who had no cancer, were examined on a clinical 7 Tesla MRI system. For morphological analysis a 3D T1-weighted fat-suppressed fast-field-echo [isotropic resolution 180 µm] was acquired. For quantitative analyses 2D T1-, 3D T2-, T2*- and diffusion-weighted images were acquired. The ALNDs were mapped and stained for precise correlation of MRI to pathology. Nodes were sliced in 3 µm sections, Haematoxylin & Eosin stained, and examined by an experienced pathologist. RESULTS: MRI detected all 45 nodes and 6 additional nodes that were not detected at pathological analysis. B-cell follicles, efferent- and afferent lymph vessels and blood vessels were identified. Mean T1, T2, T2*, ADC values (± standard deviation) were 944 ± 113 ms, 32 ± 2 ms, 16 ± 2 ms, 0.39 ± 0.09·10⁻³ mm²/s, respectively. CONCLUSIONS: 7 Tesla MRI of ex vivo human axillary lymph nodes correlated well with pathology. MRI detected all nodes present in the specimens and allowed visualization of fine structural detail. Pathology-correlated quantitative MRI data are presented.


Asunto(s)
Aumento de la Imagen/métodos , Ganglios Linfáticos/anatomía & histología , Imagen por Resonancia Magnética/métodos , Axila , Femenino , Humanos , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
AJNR Am J Neuroradiol ; 42(11): 2030-2033, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34561212

RESUMEN

We compared velocity pulsatility, distensibility, and pulsatility attenuation along the intracranial ICA and MCA between 50 patients with pseudoxanthoma elasticum and 40 controls. Patients with pseudoxanthoma elasticum had higher pulsatility and lower distensibility at all measured locations, except for a similar distensibility at C4. The pulsatility attenuation over the siphon was similar between patients with pseudoxanthoma elasticum and controls. This finding suggests that other disease mechanisms are the main contributors to increased intracranial pulsatility in pseudoxanthoma elasticum.


Asunto(s)
Seudoxantoma Elástico , Arteria Carótida Interna , Humanos , Seudoxantoma Elástico/diagnóstico por imagen
17.
AJNR Am J Neuroradiol ; 39(6): 1112-1120, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29674412

RESUMEN

BACKGROUND AND PURPOSE: Intracranial vessel wall MR imaging plays an increasing role in diagnosing intracranial vascular diseases. For a complete assessment, pre- and postcontrast sequences are required, and including other sequences, these result in a long scan duration. Ideally, the scan time of the vessel wall sequence should be reduced. The purpose of this study was to evaluate different intracranial vessel wall sequence variants to reduce scan duration, provided an acceptable image quality can be maintained. MATERIALS AND METHODS: Starting from the vessel wall sequence that we use clinically (6:42 minutes), 6 scan variants were tested (scan duration ranging between 4:39 and 8:24 minutes), creating various trade-offs among spatial resolution, SNR, and contrast-to-noise ratio. In total, 15 subjects were scanned on a 3T MR imaging scanner: In 5 subjects, all 7 variants were performed precontrast-only, and in 10 other subjects, the fastest variant (4:39 minutes) and our clinically used variant (6:42 minutes) were performed pre- and postcontrast. RESULTS: The fastest variant (4:39 minutes) had higher or comparable SNRs/contrast-to-noise ratios of the intracranial vessel walls compared with the reference sequence (6:42 minutes). Qualitative assessment showed that the contrast-to-noise ratio was most suppressed in the fastest variant of 4:39 minutes and the variant of 6:42 minutes pre- and postcontrast. SNRs/contrast-to-noise ratios of the fastest variant were all, except one, higher compared with the variant of 6:42 minutes (P < .008). Furthermore, the fastest variant (4:39 minutes) detected all vessel wall lesions identified on the 6:42-minute variant. CONCLUSIONS: A 30% faster vessel wall sequence was developed with high SNRs/contrast-to-noise ratios that resulted in good visibility of the intracranial vessel wall.


Asunto(s)
Vasos Sanguíneos/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Imagen por Resonancia Magnética/métodos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Relación Señal-Ruido
18.
AJNR Am J Neuroradiol ; 39(4): 713-719, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29472302

RESUMEN

BACKGROUND AND PURPOSE: Aneurysm volume pulsation is a potential predictor of intracranial aneurysm rupture. We evaluated whether 7T MR imaging can quantify aneurysm volume pulsation. MATERIALS AND METHODS: In Stage I of the study, 10 unruptured aneurysms in 9 patients were studied using a high-resolution (0.6-mm, isotropic) 3D gradient-echo sequence with cardiac gating. Semiautomatic segmentation was used to measure aneurysm volume (in cubic millimeters) per cardiac phase. Aneurysm pulsation was defined as the relative increase in volume between the phase with the smallest volume and the phase with the largest volume. The accuracy and precision of the measured volume pulsations were addressed by digital phantom simulations and a repeat image analysis. In Stage II, the imaging protocol was optimized and 9 patients with 9 aneurysms were studied with and without administration of a contrast agent. RESULTS: The mean aneurysm pulsation in Stage I was 8% ± 7% (range, 2%-27%), with a mean volume change of 15 ± 14 mm3 (range, 3-51 mm3). The mean difference in volume change for the repeat image analysis was 2 ± 6 mm3. The artifactual volume pulsations measured with the digital phantom simulations were of the same magnitude as the volume pulsations observed in the patient data, even after protocol optimization in Stage II. CONCLUSIONS: Volume pulsation quantification with the current imaging protocol on 7T MR imaging is not accurate due to multiple imaging artifacts. Future studies should always include aneurysm-specific accuracy analysis.


Asunto(s)
Aneurisma Intracraneal/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Adulto , Anciano , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Flujo Pulsátil
19.
AJNR Am J Neuroradiol ; 37(7): 1310-7, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26892986

RESUMEN

BACKGROUND AND PURPOSE: Both hemodynamics and aneurysm wall thickness are important parameters in aneurysm pathophysiology. Our aim was to develop a method for semi-quantitative wall thickness assessment on in vivo 7T MR images of intracranial aneurysms for studying the relation between apparent aneurysm wall thickness and wall shear stress. MATERIALS AND METHODS: Wall thickness was analyzed in 11 unruptured aneurysms in 9 patients who underwent 7T MR imaging with a TSE-based vessel wall sequence (0.8-mm isotropic resolution). A custom analysis program determined the in vivo aneurysm wall intensities, which were normalized to the signal of nearby brain tissue and were used as measures of apparent wall thickness. Spatial wall thickness variation was determined as the interquartile range in apparent wall thickness (the middle 50% of the apparent wall thickness range). Wall shear stress was determined by using phase-contrast MR imaging (0.5-mm isotropic resolution). We performed visual and statistical comparisons (Pearson correlation) to study the relation between wall thickness and wall shear stress. RESULTS: 3D colored apparent wall thickness maps of the aneurysms showed spatial apparent wall thickness variation, which ranged from 0.07 to 0.53, with a mean variation of 0.22 (a variation of 1.0 roughly means a wall thickness variation of 1 voxel [0.8 mm]). In all aneurysms, apparent wall thickness was inversely related to wall shear stress (mean correlation coefficient, -0.35; P < .05). CONCLUSIONS: A method was developed to measure the wall thickness semi-quantitatively, by using 7T MR imaging. An inverse correlation between wall shear stress and apparent wall thickness was determined. In future studies, this noninvasive method can be used to assess spatial wall thickness variation in relation to pathophysiologic processes such as aneurysm growth and rupture.


Asunto(s)
Imagenología Tridimensional/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/fisiopatología , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Anciano , Femenino , Hemodinámica/fisiología , Humanos , Aneurisma Intracraneal/patología , Masculino , Persona de Mediana Edad , Estrés Mecánico
20.
AJNR Am J Neuroradiol ; 37(6): 1050-7, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26846925

RESUMEN

BACKGROUND AND PURPOSE: High resolution 7T MRI is increasingly used to investigate hippocampal subfields in vivo, but most studies rely on manual segmentation which is labor intensive. We aimed to evaluate an automated technique to segment hippocampal subfields and the entorhinal cortex at 7T MRI. MATERIALS AND METHODS: The cornu ammonis (CA)1, CA2, CA3, dentate gyrus, subiculum, and entorhinal cortex were manually segmented, covering most of the long axis of the hippocampus on 0.70-mm(3) T2-weighted 7T images of 26 participants (59 ± 9 years, 46% men). The automated segmentation of hippocampal subfields approach was applied and evaluated by using leave-one-out cross-validation. RESULTS: Comparison of automated segmentations with corresponding manual segmentations yielded a Dice similarity coefficient of >0.75 for CA1, the dentate gyrus, subiculum, and entorhinal cortex and >0.54 for CA2 and CA3. Intraclass correlation coefficients were >0.74 for CA1, the dentate gyrus, and subiculum; and >0.43 for CA2, CA3, and the entorhinal cortex. Restricting the comparison of the entorhinal cortex segmentation to a smaller range along the anteroposterior axis improved both intraclass correlation coefficients (left: 0.71; right: 0.82) and Dice similarity coefficients (left: 0.78; right: 0.77). The accuracy of the automated segmentation versus a manual rater was lower, though only slightly for most subfields, than the intrarater reliability of an expert manual rater, but it was similar to or slightly higher than the accuracy of an expert-versus-manual rater with ∼170 hours of training for almost all subfields. CONCLUSIONS: This work demonstrates the feasibility of using a computational technique to automatically label hippocampal subfields and the entorhinal cortex at 7T MRI, with a high accuracy for most subfields that is competitive with the labor-intensive manual segmentation. The software and atlas are publicly available: http://www.nitrc.org/projects/ashs/.


Asunto(s)
Hipocampo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Anciano , Automatización , Región CA1 Hipocampal/diagnóstico por imagen , Región CA2 Hipocampal/diagnóstico por imagen , Región CA3 Hipocampal/diagnóstico por imagen , Giro Dentado/diagnóstico por imagen , Corteza Entorrinal/diagnóstico por imagen , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA