RESUMEN
OBJECTIVE: This study aimed to assess the efficacy and tolerability of stereotactic body radiation therapy (SBRT) for the treatment of liver metastases. METHODS: Patients with up to 5 liver metastases were enrolled in this prospective multicenter study and underwent SBRT. Efficacy outcomes included in-field local control (LC), progression-free survival (PFS), and overall survival (OS). Acute and late toxicities were evaluated using CTCAE v.4.0. RESULTS: A total of 52 patients with 105 liver metastases were treated between 2015 and 2018. The most common primary tumor was colorectal cancer (72% of cases). Liver metastases were synchronous with the primary tumor diagnosis in 24 patients (46.2%), and 21 patients (40.4%) presented with other extrahepatic oligometastases. All patients underwent intensity-modulated radiation therapy (IMRT)/volumetric-modulated arc therapy (VMAT) with image-guided radiation therapy (IGRT) and respiratory gating, and a minimum biologically effective dose (BED10Gy) of 100 Gy was delivered to all lesions. With a median follow-up of 23.1 months (range: 13.4-30.9 months) since liver SBRT, the median actuarial local progression-free survival (local-PFS) was not reached. The actuarial in-field LC rates were 84.9% and 78.4% at 24 and 48 months, respectively. The median actuarial liver-PFS and distant-PFS were 11 and 10.8 months, respectively. The actuarial median overall survival (OS) was 27.7 months from SBRT and 52.5 months from metastases diagnosis. Patients with lesion diameter ≤ 5 cm had significantly better median liver-PFS (p = 0.006) and OS (p = 0.018). No acute or late toxicities of grade ≥ 3 were observed. CONCLUSIONS: This prospective multicenter study confirms that liver SBRT is an effective alternative for the treatment of liver metastases, demonstrating high rates of local control and survival while maintaining a low toxicity profile.
Asunto(s)
Neoplasias Hepáticas , Radiocirugia , Radioterapia de Intensidad Modulada , Humanos , Radiocirugia/métodos , Radiocirugia/efectos adversos , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/mortalidad , Masculino , Estudios Prospectivos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Adulto , Radioterapia de Intensidad Modulada/métodos , Supervivencia sin Progresión , Neoplasias Colorrectales/patología , Neoplasias Colorrectales/radioterapia , Neoplasias Colorrectales/mortalidad , Radioterapia Guiada por Imagen , Tasa de SupervivenciaRESUMEN
Background and purpose: In lung Stereotactic Body Radiotherapy (SBRT) respiratory management is used to reduce target motion due to respiration. This study aimed (1) to estimate intrafraction shifts through a Cone Beam Computed Tomography (CBCT) acquired during the first treatment arc when deep inspiration breath-hold (DIBH) was performed using spirometry-based (SB) or surface-guidance (SG) systems and (2) to analyze the obtained results depending on lesion localization. Material and methods: A sample of 157 patients with 243 lesions was analyzed. A total of 860 and 410 fractions were treated using SB and SG. Averaged intrafraction shifts were estimated by the offsets obtained when registering a CBCT acquired during the first treatment arc with the planning CT. Offsets were recorded in superior-inferior (SI), left-right (LR) and anterior-posterior (AP). Significance tests were applied to account for differences in average offsets and variances between DIBH systems. Systematic and random errors were computed. Results: Average offset moduli were 2.4 ± 2.2 mm and 3.5 ± 2.6 mm for SB and SG treatments (p < 0.001). When comparing SB and SG offset distributions in each direction no differences were found in average values (p > 0.3). However, variances were statistically smaller for SB than for SG (p < 0.001). The number of vector moduli offsets greater than 5 mm was 2.1 times higher for SG. Compared to other locations, lower lobe lesions moduli were at least 2.3 times higher. Conclusions: Both systems were accuracy-equivalent but not precision-equivalent systems. Furthermore, the SB system was more precise than the SG one. Despite DIBH, patients with lower lobe lesions had larger offsets than superior lobe ones, mainly in SI.