Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Int J Biometeorol ; 68(3): 463-477, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38189989

RESUMEN

Here, we evaluated the influence of outdoor environmental conditions (synoptic weather conditions) on human thermal discomfort in the five macro-regions of Pelotas city, located in the southernmost region of Brazil. To do this, meteorological sensors (HOBO MX2301A) were installed outside the residences to measure the air temperature, dew point temperature, and relative humidity between 18 January and 20 August 2019. Two well-established simplified biometeorological indices were examined seasonally: (i) humidex for the summer months and (ii) effective temperature as a function of wind for the autumn and winter months. Our findings showed seasonal differences related to human thermal discomfort and outdoor environmental conditions. The thermal discomfort was highest in the afternoons during the summer months and at night during the winter months. The seasonal variation in human thermal discomfort was highly associated with the meteorological conditions. In summer, the presence of the South Atlantic Subtropical Anticyclone (SASA) contributed to heat stress. The SASA combined with the continent's low humidity contributed to the perceived sensation of thermal discomfort. In the winter, thermal discomfort was associated with the decrease in air humidity caused by high atmospheric pressure systems, which led to a decrease in both air temperature and air moisture content. Our findings suggest that a better understanding of the complex interplay between outdoor environmental factors and human thermal comfort is needed in order to mitigate the negative effects of thermal discomfort.


Asunto(s)
Sensación Térmica , Tiempo (Meteorología) , Humanos , Brasil/epidemiología , Humedad , Temperatura , Estaciones del Año
2.
Int J Biometeorol ; 66(11): 2301-2308, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36053296

RESUMEN

This work aims to analyze the relationship between meteorological conditions and the occurrence of hospital admissions for pneumonia in children under 5 years of age in the Metropolitan Region of Porto Alegre, Brazil, from 1998 to 2017. To this end, data from hospital admissions obtained from the Unified Health System database (DATASUS) were used and classified into two groups: acute respiratory infections (ARI) and asthma, according to the international classification of diseases, tenth edition (ICD-10). Data regarding meteorological variables were also used: temperature, relative humidity, atmospheric pressure and wind speed, at 12Z and 18Z, as well as the Thermal Comfort Index (TCI), Effective Temperature as a function of the wind (ETw) and Windchill (W). From the data obtained, a descriptive analysis of the diseases and a statistical analysis with the analysis of correlation and main components were performed. Results showed that pneumonia (catalogued in the ICD-10 as J12 to J18) was the main cause of hospitalizations in children. The annual, monthly and daily hospitalization frequency distributions showed higher rates of admissions occurring in the months of May to September. The peaks of admissions and high admissions (HA) occurred mainly in the winter months (June, July and August), and in 1998. Meanwhile, the correlation and principal component analysis showed an increase in hospital admissions due to pneumonia related to a decrease in temperature and ETw and W indices (negative anomalies) and an increase in atmospheric pressure and relative humidity (positive anomalies).


Asunto(s)
Asma , Neumonía , Niño , Humanos , Preescolar , Brasil/epidemiología , Neumonía/epidemiología , Estaciones del Año , Hospitalización , Asma/epidemiología
3.
Int J Biometeorol ; 65(3): 419-428, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32902723

RESUMEN

The indoor human thermal comfort (HTC) was investigated in residences located in the Pelotas City, southern Brazil, by the effective temperature index (ETI). In this study, temperature and relative humidity were measured inside 429 houses, located in different regions of Pelotas city, from January 11 to August 27, 2019. Samples were obtained using HOBO data loggers, indoor sensors, installed in different regions of the municipality, in the context of a cohort study of children between 2 and 4 years old and their respective mothers, led by Epidemiological Research Center of the Federal University of Pelotas (UFPEL). In general, all regions had average hourly values of effective temperature index above the comfort zone in summer and below the comfort zone in the winter. In terms of spatial variability, the indoor HTC was dependent on environmental factors such as lake breeze and indoor behavior factors, such as the use of air conditioning system in the downtown buildings.


Asunto(s)
Aire Acondicionado , Brasil , Niño , Preescolar , Ciudades , Estudios de Cohortes , Humanos , Humedad , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA