Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 149(6): e296-e311, 2024 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-38193315

RESUMEN

Multiple applications for machine learning and artificial intelligence (AI) in cardiovascular imaging are being proposed and developed. However, the processes involved in implementing AI in cardiovascular imaging are highly diverse, varying by imaging modality, patient subtype, features to be extracted and analyzed, and clinical application. This article establishes a framework that defines value from an organizational perspective, followed by value chain analysis to identify the activities in which AI might produce the greatest incremental value creation. The various perspectives that should be considered are highlighted, including clinicians, imagers, hospitals, patients, and payers. Integrating the perspectives of all health care stakeholders is critical for creating value and ensuring the successful deployment of AI tools in a real-world setting. Different AI tools are summarized, along with the unique aspects of AI applications to various cardiac imaging modalities, including cardiac computed tomography, magnetic resonance imaging, and positron emission tomography. AI is applicable and has the potential to add value to cardiovascular imaging at every step along the patient journey, from selecting the more appropriate test to optimizing image acquisition and analysis, interpreting the results for classification and diagnosis, and predicting the risk for major adverse cardiac events.


Asunto(s)
American Heart Association , Inteligencia Artificial , Humanos , Aprendizaje Automático , Corazón , Imagen por Resonancia Magnética
2.
Curr Atheroscler Rep ; 26(4): 91-102, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38363525

RESUMEN

PURPOSE OF REVIEW: Bias in artificial intelligence (AI) models can result in unintended consequences. In cardiovascular imaging, biased AI models used in clinical practice can negatively affect patient outcomes. Biased AI models result from decisions made when training and evaluating a model. This paper is a comprehensive guide for AI development teams to understand assumptions in datasets and chosen metrics for outcome/ground truth, and how this translates to real-world performance for cardiovascular disease (CVD). RECENT FINDINGS: CVDs are the number one cause of mortality worldwide; however, the prevalence, burden, and outcomes of CVD vary across gender and race. Several biomarkers are also shown to vary among different populations and ethnic/racial groups. Inequalities in clinical trial inclusion, clinical presentation, diagnosis, and treatment are preserved in health data that is ultimately used to train AI algorithms, leading to potential biases in model performance. Despite the notion that AI models themselves are biased, AI can also help to mitigate bias (e.g., bias auditing tools). In this review paper, we describe in detail implicit and explicit biases in the care of cardiovascular disease that may be present in existing datasets but are not obvious to model developers. We review disparities in CVD outcomes across different genders and race groups, differences in treatment of historically marginalized groups, and disparities in clinical trials for various cardiovascular diseases and outcomes. Thereafter, we summarize some CVD AI literature that shows bias in CVD AI as well as approaches that AI is being used to mitigate CVD bias.


Asunto(s)
Inteligencia Artificial , Enfermedades Cardiovasculares , Femenino , Masculino , Humanos , Enfermedades Cardiovasculares/diagnóstico por imagen , Algoritmos , Sesgo
3.
J Korean Med Sci ; 39(32): e228, 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39164053

RESUMEN

BACKGROUND: We evaluated the radiologic, pulmonary functional, and antibody statuses of coronavirus disease 2019 (COVID-19) patients 6 and 18 months after discharge, comparing changes in status and focusing on risk factors for residual computed tomography (CT) abnormalities. METHODS: This prospective cohort study was conducted on COVID-19 patients discharged between April 2020 and January 2021. Chest CT, pulmonary function testing (PFT), and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) immunoglobulin G (IgG) measurements were performed 6 and 18 months after discharge. We evaluated factors associated with residual CT abnormalities and the correlation between lesion volume in CT (lesionvolume), PFT, and IgG levels. RESULTS: This study included 68 and 42 participants evaluated 6 and 18 months, respectively, after hospitalizations for COVID-19. CT abnormalities were noted in 22 participants (32.4%) at 6 months and 13 participants (31.0%) at 18 months. Lesionvolume was significantly lower at 18 months than 6 months (P < 0.001). Patients with CT abnormalities at 6 months showed lower forced expiratory volume in 1 second (FEV1) and FEV1/forced vital capacity (FVC), and patients with CT abnormalities at 18 months exhibited lower FVC. FVC significantly improved between 6 and 18 months of follow-up (all P < 0.0001). SARS-CoV-2 IgG levels were significantly higher in patients with CT abnormalities at 6 and 18 months (P < 0.001). At 18-month follow-up assessments, age was associated with CT abnormalities (odds ratio, 1.17; 95% confidence interval, 1.03-1.32; P = 0.01), and lesionvolume showed a positive correlation with IgG level (r = 0.643, P < 0.001). CONCLUSION: At 18-month follow-up assessments, 31.0% of participants exhibited residual CT abnormalities. Age and higher SARS-CoV-2 IgG levels were significant predictors, and FVC was related to abnormal CT findings at 18 months. Lesionvolume and FVC improved between 6 and 18 months. TRIAL REGISTRATION: Clinical Research Information Service Identifier: KCT0008573.


Asunto(s)
COVID-19 , Inmunoglobulina G , Pulmón , Pruebas de Función Respiratoria , SARS-CoV-2 , Tomografía Computarizada por Rayos X , Humanos , COVID-19/diagnóstico por imagen , Masculino , Femenino , Estudios Prospectivos , Persona de Mediana Edad , Inmunoglobulina G/sangre , SARS-CoV-2/inmunología , SARS-CoV-2/aislamiento & purificación , Anciano , Estudios de Seguimiento , Pulmón/diagnóstico por imagen , Pulmón/patología , Anticuerpos Antivirales/sangre , Adulto , Volumen Espiratorio Forzado , Capacidad Vital , Factores de Riesgo
4.
J Nucl Cardiol ; 30(5): 2029-2038, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36991249

RESUMEN

Microcirculatory dysfunction during psychological stress may lead to diffuse myocardial ischemia. We developed a novel quantification method for diffuse ischemia during mental stress (dMSI) and examined its relationship with outcomes after a myocardial infarction (MI). We studied 300 patients ≤ 61 years of age (50% women) with a recent MI. Patients underwent myocardial perfusion imaging with mental stress and were followed for 5 years. dMSI was quantified from cumulative count distributions of rest and stress perfusion. Focal ischemia was defined in a conventional fashion. The main outcome was a composite outcome of recurrent MI, heart failure hospitalizations, and cardiovascular death. A dMSI increment of 1 standard deviation was associated with a 40% higher risk for adverse events (HR 1.4, 95% CI 1.2-1.5). Results were similar after adjustment for viability, demographic and clinical factors and focal ischemia. In sex-specific analysis, higher levels of dMSI (per standard deviation increment) were associated with 53% higher risk of adverse events in women (HR 1.5, 95% CI 1.2-2.0) but not in men (HR 0.9, 95% CI 0.5-1.4), P 0.001. A novel index of diffuse ischemia with mental stress was associated with recurrent events in women but not in men after MI.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Isquemia Miocárdica , Masculino , Humanos , Femenino , Microcirculación , Infarto del Miocardio/complicaciones , Estrés Psicológico/complicaciones
5.
Eur Heart J Suppl ; 25(Suppl C): C112-C117, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37125298

RESUMEN

The field of coronary plaque analysis is advancing including more quantitative analysis of coronary artery diseases such as plaque burden, high-risk plaque features, computed tomography-derived fractional flow reserve, and radiomics. Although these biomarkers have shown great promise for the diagnosis and prognosis of cardiac patients in a research setting, many of these advanced analyses are labour and time intensive and therefore hard to implement in daily clinical practice. Artificial intelligence (AI) is playing an increasing role in supporting the quantification of these new biomarkers. AI offers the opportunity to increase efficiency, reduce human error and reader variability and to increase the accuracy of diagnosis and prognosis by automating many processing and supporting clinicians in their decision-making. With the use of AI these novel analysis approaches for coronary artery disease can be made feasible for clinical practice without increasing cost and workload and potentially improve patient care.

6.
Eur Radiol ; 31(10): 7251-7261, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33860371

RESUMEN

OBJECTIVES: To investigate the association of pericoronary adipose tissue mean attenuation (PCATMA) with coronary artery disease (CAD) characteristics on coronary computed tomography angiography (CCTA). METHODS: We retrospectively investigated 165 symptomatic patients who underwent third-generation dual-source CCTA at 70kVp: 93 with and 72 without CAD (204 arteries with plaque, 291 without plaque). CCTA was evaluated for presence and characteristics of CAD per artery. PCATMA was measured proximally and across the most severe stenosis. Patient-level, proximal PCATMA was defined as the mean of the proximal PCATMA of the three main coronary arteries. Analyses were performed on patient and vessel level. RESULTS: Mean proximal PCATMA was -96.2 ± 7.1 HU and -95.6 ± 7.8HU for patients with and without CAD (p = 0.644). In arteries with plaque, proximal and lesion-specific PCATMA was similar (-96.1 ± 9.6 HU, -95.9 ± 11.2 HU, p = 0.608). Lesion-specific PCATMA of arteries with plaque (-94.7 HU) differed from proximal PCATMA of arteries without plaque (-97.2 HU, p = 0.015). Minimal stenosis showed higher lesion-specific PCATMA (-94.0 HU) than severe stenosis (-98.5 HU, p = 0.030). Lesion-specific PCATMA of non-calcified, mixed, and calcified plaque was -96.5 HU, -94.6 HU, and -89.9 HU (p = 0.004). Vessel-based total plaque, lipid-rich necrotic core, and calcified plaque burden showed a very weak to moderate correlation with proximal PCATMA. CONCLUSIONS: Lesion-specific PCATMA was higher in arteries with plaque than proximal PCATMA in arteries without plaque. Lesion-specific PCATMA was higher in non-calcified and mixed plaques compared to calcified plaques, and in minimal stenosis compared to severe; proximal PCATMA did not show these relationships. This suggests that lesion-specific PCATMA is related to plaque development and vulnerability. KEY POINTS: • In symptomatic patients undergoing CCTA at 70 kVp, PCATMA was higher in coronary arteries with plaque than those without plaque. • PCATMA was higher for non-calcified and mixed plaques compared to calcified plaques, and for minimal stenosis compared to severe stenosis. • In contrast to PCATMA measurement of the proximal vessels, lesion-specific PCATMA showed clear relationships with plaque presence and stenosis degree.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Placa Aterosclerótica , Tejido Adiposo/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Constricción Patológica , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Humanos , Placa Aterosclerótica/diagnóstico por imagen , Valor Predictivo de las Pruebas , Estudios Retrospectivos
7.
AJR Am J Roentgenol ; 217(2): 336-346, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-32936016

RESUMEN

BACKGROUND. Transthoracic echocardiography (TTE) is the standard of care for initial evaluation of patients with suspected cardioembolic stroke. Although TTE is useful for assessing certain sources of cardiac emboli, its diagnostic capability is limited in the detection of other sources, including left atrial thrombus and aortic plaques. OBJECTIVE. The purpose of this article was to investigate sensitivity, specificity, and predictive value of cardiac CTA (CCTA), cardiac MRI (CMRI), and TTE for recurrence in patients with suspected cardioembolic stroke. METHODS. We retrospectively included 151 patients with suspected cardioembolic stroke who underwent TTE and either CMRI (n = 75) or CCTA (n = 76) between January 2013 and May 2017. We evaluated for the presence of left atrial thrombus, left ventricular thrombus, vulnerable aortic plaque, cardiac tumors, and valvular vegetation as causes of cardioembolic stroke. The end point was stroke recurrence. Sensitivity, specificity, PPV, and NPV for recurrent stroke were calculated; the diagnostic accuracy of CMRI, CCTA, and TTE was compared between and within groups using AUC. RESULTS. Twelve and 14 recurrent strokes occurred in the CCTA and CMRI groups, respectively. Sensitivity, specificity, PPV, and NPV were 33.3%, 93.7%, 50.0%, and 88.2% for CCTA; 14.3%, 80.3%, 14.3%, and 80.3% for CMRI; 14.3%, 83.6%, 16.7%, and 80.9% for TTE in the CMRI group; and 8.3%, 93.7%, 20.0%, and 84.5% for TTE in the CCTA group. Accuracy was not different (p > .05) between CCTA (AUC = 0.63; 95% CI, 0.49-0.77), CMRI (0.53; 95% CI, 0.42-0.63), TTE in the CMRI group (0.51; 95% CI, 0.40-0.61), and TTE in the CCTA group (0.51; 95% CI, 0.42-0.59). In the CCTA group, atrial and ventricular thrombus were detected by CCTA in three patients and TTE in one patient; in the CMRI group, thrombus was detected by CMRI in one patient and TTE in two patients. CONCLUSION. CCTA, CMRI, and TTE showed comparably high specificity and NPV for cardioembolic stroke recurrence. CCTA and CMRI may be valid alternatives to TTE. CCTA may be preferred given potentially better detection of atrial and ventricular thrombus. CLINICAL IMPACT. CCTA and CMRI have similar clinical performance as TTE for predicting cardioembolic stroke recurrence. This observation may be especially important when TTE provides equivocal findings.


Asunto(s)
Ecocardiografía/métodos , Accidente Cerebrovascular Embólico/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Femenino , Corazón/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Recurrencia , Estudios Retrospectivos , Sensibilidad y Especificidad
8.
Eur Radiol ; 30(12): 6528-6536, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32617689

RESUMEN

OBJECTIVE: To evaluate a novel fully automated mitral valve analysis software platform for cardiac computer tomography angiography (CCTA)-based structural heart therapy procedure planning. METHODS: The study included 52 patients (25 women; mean age, 66.9 ± 12.4 years) who had undergone CCTA prior to transcatheter mitral valve replacement (TMVR) or surgical mitral valve intervention (replacement or repair). Therapeutically relevant mitral valve annulus parameters (projected area, circumference, trigone-to-trigone (T-T) distance, anterior-posterior (AP) diameter, and anterolateral-posteromedial (AL-PM) diameter) were measured. Results of the fully automated mitral valve analysis software platform with and without manual adjustments were compared with the reference standard of a user-driven measurement program (3mensio, Pie Medical Imaging). Measurements were compared between the fully automated software, both with and without manual adjustment, and the user-driven program using intraclass correlation coefficients (ICC). A secondary analysis included the time to obtain all measurements. RESULTS: Fully automated measurements showed a good to excellent agreement (circumference, ICC = 0.70; projected area, ICC = 0.81; T-T distance, ICC = 0.64; AP, ICC = 0.62; and AL-PM diameter, ICC = 0.78) compared with the user-driven analysis. There was an excellent agreement between fully automated measurement with manual adjustments and user-driven analysis regarding circumference (ICC = 0.91), projected area (ICC = 0.93), T-T distance (ICC = 0.80), AP (ICC = 0.78), and AL-PM diameter (ICC = 0.79). The time required for mitral valve analysis was significantly lower using the fully automated software with manual adjustments compared with the standard assessment (134.4 ± 36.4 s vs. 304.3 ± 77.7 s) (p < 0.01). CONCLUSION: The fully automated mitral valve analysis software, when combined with manual adjustments, demonstrated a strong correlation compared with the user-driven software while reducing the total time required for measurement. KEY POINTS: • The novel software platform allows for a fully automated analysis of mitral valve structures. • An excellent agreement was found between the fully automated measurement with manual adjustments and the user-driven analysis. • The software showed quicker measurement time compared with the standard analysis of the mitral valve.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Válvula Mitral/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Reconocimiento de Normas Patrones Automatizadas , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Programas Informáticos
9.
Eur Radiol ; 30(12): 6838-6846, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32700017

RESUMEN

OBJECTIVES: To determine normal pericoronary adipose tissue mean attenuation (PCATMA) values for left the anterior descending (LAD), left circumflex (LCX), and right coronary artery (RCA) in patients without plaques on coronary CT angiography (cCTA), taking into account tube voltage influence. METHODS: This retrospective study included 192 patients (76 (39.6%) men; median age 49 years (range, 19-79)) who underwent cCTA with third-generation dual-source CT for the suspicion of CAD between 2015 and 2017. We selected patients without plaque on cCTA. PCATMA was measured semi-automatically on cCTA images in the proximal segment of the three main coronary arteries with 10 mm length. Paired t-testing was used to compare PCATMA between combinations of two coronary arteries within each patient, and one-way ANOVA testing was used to compare PCATMA in different kV groups. RESULTS: The overall mean ± standard deviation (SD) PCATMA was - 90.3 ± 11.1 HU. PCATMA in men was higher than that in women: - 88.5 ± 10.5 HU versus - 91.5 ± 11.3 HU (p = 0.001). PCATMA of LAD, LCX, and RCA was - 92.4 ± 11.6 HU, - 88.4 ± 9.9 HU, and - 90.2 ± 11.4 HU, respectively. Pairwise comparison of the arteries showed significant difference in PCATMA: LAD and LCX (p < 0.001), LAD and RCA (p = 0.009), LCX and RCA (p = 0.033). PCATMA of the 70 kV, 80 kV, 90 kV, 100 kV, and 120 kV groups was - 95.6 ± 9.6 HU, - 90.2 ± 11.5 HU, - 87.3 ± 9.9 HU, - 82.7 ± 6.2 HU, and - 79.3 ± 6.8 HU, respectively (p < 0.001). CONCLUSIONS: In patients without plaque on cCTA, PCATMA varied by tube voltage, with minor differences in PCATMA between coronary arteries (LAD, LCX, RCA). PCATMA values need to be interpreted taking into account tube voltage setting. KEY POINTS: • In patients without plaque on cCTA, PCATMA differs slightly by coronary artery (LAD, LCX, RCA). • Tube voltage of cCTA affects PCATMA measurement, with mean PCATMA increasing linearly with increasing kV. • For longitudinal cCTA analysis of PCATMA , the use of equal kV setting is strongly recommended.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Placa Aterosclerótica/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Reproducibilidad de los Resultados , Estudios Retrospectivos , Adulto Joven
10.
AJR Am J Roentgenol ; 214(5): 1065-1071, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32130041

RESUMEN

OBJECTIVE. The purpose of this study was to evaluate an artificial intelligence (AI)-based prototype algorithm for fully automated quantification of emphysema on chest CT compared with pulmonary function testing (spirometry). MATERIALS AND METHODS. A total of 141 patients (72 women, mean age ± SD of 66.46 ± 9.7 years [range, 23-86 years]; 69 men, mean age of 66.72 ± 11.4 years [range, 27-91 years]) who underwent both chest CT acquisition and spirometry within 6 months were retrospectively included. The spirometry-based Tiffeneau index (TI; calculated as the ratio of forced expiratory volume in the first second to forced vital capacity) was used to measure emphysema severity; a value less than 0.7 was considered to indicate airway obstruction. Segmentation of the lung based on two different reconstruction methods was carried out by using a deep convolution image-to-image network. This multilayer convolutional neural network was combined with multilevel feature chaining and depth monitoring. To discriminate the output of the network from ground truth, an adversarial network was used during training. Emphysema was quantified using spatial filtering and attenuation-based thresholds. Emphysema quantification and TI were compared using the Spearman correlation coefficient. RESULTS. The mean TI for all patients was 0.57 ± 0.13. The mean percentages of emphysema using reconstruction methods 1 and 2 were 9.96% ± 11.87% and 8.04% ± 10.32%, respectively. AI-based emphysema quantification showed very strong correlation with TI (reconstruction method 1, ρ = -0.86; reconstruction method 2, ρ = -0.85; both p < 0.0001), indicating that AI-based emphysema quantification meaningfully reflects clinical pulmonary physiology. CONCLUSION. AI-based, fully automated emphysema quantification shows good correlation with TI, potentially contributing to an image-based diagnosis and quantification of emphysema severity.


Asunto(s)
Inteligencia Artificial , Enfisema Pulmonar/diagnóstico por imagen , Pruebas de Función Respiratoria , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos
11.
Radiol Med ; 125(11): 1186-1199, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32946002

RESUMEN

Artificial intelligence (AI) is entering the clinical arena, and in the early stage, its implementation will be focused on the automatization tasks, improving diagnostic accuracy and reducing reading time. Many studies investigate the potential role of AI to support cardiac radiologist in their day-to-day tasks, assisting in segmentation, quantification, and reporting tasks. In addition, AI algorithms can be also utilized to optimize image reconstruction and image quality. Since these algorithms will play an important role in the field of cardiac radiology, it is increasingly important for radiologists to be familiar with the potential applications of AI. The main focus of this article is to provide an overview of cardiac-related AI applications for CT and MRI studies, as well as non-imaging-based applications for reporting and image optimization.


Asunto(s)
Algoritmos , Inteligencia Artificial , Corazón/diagnóstico por imagen , Radiología/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Pronóstico , Calcificación Vascular/diagnóstico por imagen , Flujo de Trabajo
12.
Radiology ; 293(2): 260-271, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31502938

RESUMEN

In this article, the authors discuss the technical background and summarize the current body of literature regarding virtual monoenergetic (VM) images derived from dual-energy CT data, which can be reconstructed between 40 and 200 keV. Substantially improved iodine attenuation at lower kiloelectron volt levels and reduced beam-hardening artifacts at higher kiloelectron volt levels have been demonstrated from all major manufacturers of dual-energy CT units. Improved contrast attenuation with VM imaging at lower kiloelectron volt levels enables better delineation and diagnostic accuracy in the detection of various vascular or oncologic abnormalities. Low-kiloelectron-volt VM imaging may be useful for salvaging CT studies with suboptimal contrast material delivery or providing additional information on the arterial vasculature obtained from venous phase acquisitions. For patients with renal impairment, substantial reductions in the use of iodinated contrast material can be achieved by using lower-energy VM imaging. The authors recommend routine reconstruction of VM images at 50 keV when using dual-energy CT to exploit the increased contrast properties. For reduction of beam-hardening artifacts, VM imaging at 120 keV is useful for the initial assessment.


Asunto(s)
Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Artefactos , Enfermedades Cardiovasculares/diagnóstico por imagen , Estenosis Carotídea/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Medios de Contraste , Humanos , Neoplasias/diagnóstico por imagen , Arteria Pulmonar/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
13.
Eur Radiol ; 29(5): 2378-2387, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30523456

RESUMEN

OBJECTIVES: We sought to investigate the diagnostic performance of coronary CT angiography (cCTA)-derived plaque markers combined with deep machine learning-based fractional flow reserve (CT-FFR) to identify lesion-specific ischemia using invasive FFR as the reference standard. METHODS: Eighty-four patients (61 ± 10 years, 65% male) who had undergone cCTA followed by invasive FFR were included in this single-center retrospective, IRB-approved, HIPAA-compliant study. Various plaque markers were derived from cCTA using a semi-automatic software prototype and deep machine learning-based CT-FFR. The discriminatory value of plaque markers and CT-FFR to identify lesion-specific ischemia on a per-vessel basis was evaluated using invasive FFR as the reference standard. RESULTS: One hundred three lesion-containing vessels were investigated. 32/103 lesions were hemodynamically significant by invasive FFR. In a multivariate analysis (adjusted for Framingham risk score), the following markers showed predictive value for lesion-specific ischemia (odds ratio [OR]): lesion length (OR 1.15, p = 0.037), non-calcified plaque volume (OR 1.02, p = 0.007), napkin-ring sign (OR 5.97, p = 0.014), and CT-FFR (OR 0.81, p < 0.0001). A receiver operating characteristics analysis showed the benefit of identifying plaque markers over cCTA stenosis grading alone, with AUCs increasing from 0.61 with ≥ 50% stenosis to 0.83 with addition of plaque markers to detect lesion-specific ischemia. Further incremental benefit was realized with the addition of CT-FFR (AUC 0.93). CONCLUSION: Coronary CTA-derived plaque markers portend predictive value to identify lesion-specific ischemia when compared to cCTA stenosis grading alone. The addition of CT-FFR to plaque markers shows incremental discriminatory power. KEY POINTS: • Coronary CT angiography (cCTA)-derived quantitative plaque markers of atherosclerosis portend high discriminatory power to identify lesion-specific ischemia. • Coronary CT angiography-derived fractional flow reserve (CT-FFR) shows superior diagnostic performance over cCTA alone in detecting lesion-specific ischemia. • A combination of plaque markers with CT-FFR provides incremental discriminatory value for detecting flow-limiting stenosis.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico , Diagnóstico por Computador/métodos , Reserva del Flujo Fraccional Miocárdico/fisiología , Aprendizaje Automático , Placa Aterosclerótica/diagnóstico , Estenosis Coronaria/etiología , Estenosis Coronaria/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Placa Aterosclerótica/complicaciones , Placa Aterosclerótica/fisiopatología , Curva ROC , Estudios Retrospectivos
16.
J Magn Reson Imaging ; 2018 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-29446527

RESUMEN

BACKGROUND: Binary threshold-based quantification techniques ignore myocardial infarct (MI) heterogeneity, yielding substantial misquantification of MI. PURPOSE: To assess the technical feasibility of MI quantification using percent infarct mapping (PIM), a prototype nonbinary algorithm, in patients with suspected MI. STUDY TYPE: Prospective cohort POPULATION: Patients (n = 171) with suspected MI referred for cardiac MRI. FIELD STRENGTH/SEQUENCE: Inversion recovery balanced steady-state free-precession for late gadolinium enhancement (LGE) and modified Look-Locker inversion recovery (MOLLI) T1 -mapping on a 1.5T system. ASSESSMENT: Infarct volume (IV) and infarct fraction (IF) were quantified by two observers based on manual delineation, binary approaches (2-5 standard deviations [SD] and full-width at half-maximum [FWHM] thresholds) in LGE images, and by applying the PIM algorithm in T1 and LGE images (PIMT1 ; PIMLGE ). STATISTICAL TEST: IV and IF were analyzed using repeated measures analysis of variance (ANOVA). Agreement between the approaches was determined with Bland-Altman analysis. Interobserver agreement was assessed by intraclass correlation coefficient (ICC) analysis. RESULTS: MI was observed in 89 (54.9%) patients, and 185 (38%) short-axis slices. IF with 2, 3, 4, 5SDs and FWHM techniques were 15.7 ± 6.6, 13.4 ± 5.6, 11.6 ± 5.0, 10.8 ± 5.2, and 10.0 ± 5.2%, respectively. The 5SD and FWHM techniques had the best agreement with manual IF (9.9 ± 4.8%) determination (bias 1.0 and 0.2%; P = 0.1426 and P = 0.8094, respectively). The 2SD and 3SD algorithms significantly overestimated manual IF (9.9 ± 4.8%; both P < 0.0001). PIMLGE measured significantly lower IF (7.8 ± 3.7%) compared to manual values (P < 0.0001). PIMLGE , however, showed the best agreement with the PIMT1 reference (7.6 ± 3.6%, P = 0.3156). Interobserver agreement was rated good to excellent for IV (ICCs between 0.727-0.820) and fair to good for IF (0.589-0.736). DATA CONCLUSION: The application of the PIMLGE technique for MI quantification in patients is feasible. PIMLGE , with its ability to account for voxelwise MI content, provides significantly smaller IF than any thresholding technique and shows excellent agreement with the T1 -based reference. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018.

17.
Radiol Clin North Am ; 62(3): 473-488, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38553181

RESUMEN

Artificial intelligence (AI) is having a significant impact in medical imaging, advancing almost every aspect of the field, from image acquisition and postprocessing to automated image analysis with outreach toward supporting decision making. Noninvasive cardiac imaging is one of the main and most exciting fields for AI development. The aim of this review is to describe the main applications of AI in cardiac imaging, including CT and MR imaging, and provide an overview of recent advancements and available clinical applications that can improve clinical workflow, disease detection, and prognostication in cardiac disease.


Asunto(s)
Inteligencia Artificial , Cardiopatías , Humanos , Cardiopatías/diagnóstico por imagen , Imagen por Resonancia Magnética , Procesamiento de Imagen Asistido por Computador
18.
Curr Probl Cardiol ; 49(7): 102585, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38688396

RESUMEN

PURPOSE: Coronary artery plaque burden, low attenuation non-calcified plaque (LAP), and pericoronary adipose tissue (PCAT) on coronary CT angiography (CCTA), have been linked to future cardiac events. The purpose of this study was to evaluate intra- and inter reader reproducibility in the quantification of coronary plaque burden and its characteristics using an artificial intelligence-enhanced semi-automated software. MATERIALS AND METHODS: A total of 10 women and 6 men, aged 52 (IQR 49-58) underwent CCTA using a Siemens Somatom Force, Somatom Definition AS and Somatom Definition Flash scanners. Two expert readers utilized dedicated semi-automatic software (vascuCAP, Elucid Bioimaging, Wenham, MA) to assess calcified plaque, low attenuation plaque and PCAT. Readers were blinded to all clinical information and repeated their analysis at 6 weeks in random order to minimize recall bias. Data analysis was performed on the right and left coronary arteries. Intra- and inter-reader reproducibility was compared using Pearson correlation coefficient, while absolute values between analyses and readers were compared with paired non-parametric tests. This is a sub-study of the Specialized Center of Research Excellence (SCORE) clinical trial (5U54AG062334). RESULTS: A total of 64 vessels from 16 patients were analyzed. Intra-reader Pearson correlation coefficients for calcified plaque volume, LAP volume and PCAT volumes were 0.96, 0.99 and 0.92 for reader 1 and 0.94, 0.94 and 0.95 for reader 2, respectively, (all p < 0.0001). Inter-reader Pearson correlation coefficients for calcified plaque volume, LAP and PCAT volumes were 0.92, 0.96 and 0.78, and 0.99, 0.99 and 0.93 on the second analyses, all had a p value <0.0001. There was no significant bias on the corresponding Bland-Altman analyses. CONCLUSION: Volume measurement of coronary plaque burden and PCAT volume can be performed with high intra- and inter-reader agreement.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Vasos Coronarios , Placa Aterosclerótica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Variaciones Dependientes del Observador , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/diagnóstico , Reproducibilidad de los Resultados
19.
Int J Cardiovasc Imaging ; 40(5): 951-966, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38700819

RESUMEN

Almost 35 years after its introduction, coronary artery calcium score (CACS) not only survived technological advances but became one of the cornerstones of contemporary cardiovascular imaging. Its simplicity and quantitative nature established it as one of the most robust approaches for atherosclerotic cardiovascular disease risk stratification in primary prevention and a powerful tool to guide therapeutic choices. Groundbreaking advances in computational models and computer power translated into a surge of artificial intelligence (AI)-based approaches directly or indirectly linked to CACS analysis. This review aims to provide essential knowledge on the AI-based techniques currently applied to CACS, setting the stage for a holistic analysis of the use of these techniques in coronary artery calcium imaging. While the focus of the review will be detailing the evidence, strengths, and limitations of end-to-end CACS algorithms in electrocardiography-gated and non-gated scans, the current role of deep-learning image reconstructions, segmentation techniques, and combined applications such as simultaneous coronary artery calcium and pulmonary nodule segmentation, will also be discussed.


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Vasos Coronarios , Aprendizaje Profundo , Valor Predictivo de las Pruebas , Interpretación de Imagen Radiográfica Asistida por Computador , Calcificación Vascular , Humanos , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/terapia , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Pronóstico , Angiografía por Tomografía Computarizada , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Inteligencia Artificial , Técnicas de Imagen Sincronizada Cardíacas
20.
J Imaging Inform Med ; 2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-39164451

RESUMEN

In this study, we present a method based on Monte Carlo Dropout (MCD) as Bayesian neural network (BNN) approximation for confidence-aware severity classification of lung diseases in COVID-19 patients using chest X-rays (CXRs). Trained and tested on 1208 CXRs from Hospital 1 in the USA, the model categorizes severity into four levels (i.e., normal, mild, moderate, and severe) based on lung consolidation and opacity. Severity labels, determined by the median consensus of five radiologists, serve as the reference standard. The model's performance is internally validated against evaluations from an additional radiologist and two residents that were excluded from the median. The performance of the model is further evaluated on additional internal and external datasets comprising 2200 CXRs from the same hospital and 1300 CXRs from Hospital 2 in South Korea. The model achieves an average area under the curve (AUC) of 0.94 ± 0.01 across all classes in the primary dataset, surpassing human readers in each severity class and achieves a higher Kendall correlation coefficient (KCC) of 0.80 ± 0.03. The performance of the model is consistent across varied datasets, highlighting its generalization. A key aspect of the model is its predictive uncertainty (PU), which is inversely related to the level of agreement among radiologists, particularly in mild and moderate cases. The study concludes that the model outperforms human readers in severity assessment and maintains consistent accuracy across diverse datasets. Its ability to provide confidence measures in predictions is pivotal for potential clinical use, underscoring the BNN's role in enhancing diagnostic precision in lung disease analysis through CXR.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA