1.
Oecologia ; 173(3): 1053-62, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23736548

RESUMEN

Assessing the importance of deterministic processes in structuring ecological communities is a central focus of community ecology. Typically, community ecologists study a single taxonomic group, which precludes detection of potentially important biotic interactions between distantly related species, and inherently assumes competition is strongest between closely related species. We examined distribution patterns of vertebrate species across the island of Borneo in Southeast Asia to assess the extent to which inter-specific competition may have shaped ecological communities on the island and whether the intensity of inter-specific competition in present-day communities varies as a function of evolutionary relatedness. We investigated the relative extent of competition within and between species of primates, birds, bats and squirrels using species presence-absence and attribute data compiled for 21 forested sites across Borneo. We calculated for each species pair the checkerboard unit value (CU), a statistic that is often interpreted as indicating the importance of interspecific competition. The percentage of species pairs with significant CUs was lowest in within-taxon comparisons. Moreover, for invertebrate-eating species the percentage of significantly checkerboarded species pairs was highest in comparisons between primates and other taxa, particularly birds and squirrels. Our results are consistent with the interpretation that competitive interactions between distantly related species may have shaped the distribution of species and thus the composition of Bornean vertebrate communities. This research highlights the importance of taking into account the broad mammalian and avian communities in which species occur for understanding the factors that structure biodiversity.


Asunto(s)
Distribución Animal/fisiología , Evolución Biológica , Conducta Competitiva/fisiología , Ecosistema , Vertebrados/fisiología , Animales , Borneo , Especificidad de la Especie
2.
Phys Med Biol ; 49(4): N31-8, 2004 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-15005170

RESUMEN

The quality of thorax and pelvis transmission scans and therefore of attenuation correction in PET depends on patient thickness and transmission rod source strength. The purpose of the present study was to assess the feasibility of using count-based transmission scans, thereby guaranteeing more consistent image quality and more precise quantification than with fixed transmission scan duration. First, the relation between noise equivalent counts (NEC) of 10 min calibration transmission scans and rod source activity was determined over a period of 1.5 years. Second, the relation between transmission scan counts and uniform phantom diameter was studied numerically, determining the relative contribution of counts from lines of response passing through the phantom as compared with the total number of counts. Finally, the relation between patient weight and transmission scan duration was determined for 35 patients, who were scanned at the level of thorax or pelvis. After installation of new rod sources, the NEC of transmission scans first increased slightly (5%) with decreasing rod source activity and after 3 months decreased with a rate of 2-3% per month. The numerical simulation showed that the number of transmission scan counts from lines of response passing through the phantom increased with phantom diameter up to 7 cm. For phantoms larger than 7 cm, the number of these counts decreased at approximately the same rate as the total number of transmission scan counts. Patient data confirmed that the total number of transmission scan counts decreased with increasing patient weight with about 0.5% kg(-1). It can be concluded that count-based transmission scans compensate for radioactive decay of the rod sources. With count-based transmission scans, rod sources can be used for up to 1.5 years at the cost of a 50% increased transmission scan duration. For phantoms with diameters of more than 7 cm and for patients scanned at the level of thorax or pelvis, use of count-based transmission scans is feasible and results in statistically more consistent transmission scans as compared with fixed transmission scan duration.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Pelvis/diagnóstico por imagen , Tórax/diagnóstico por imagen , Tomografía Computarizada de Emisión/métodos , Algoritmos , Humanos , Fantasmas de Imagen
3.
Eur J Nucl Med ; 28(1): 81-9, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11202456

RESUMEN

The first performance tests of a new fully programmable blood sampling device for monitoring blood radioactivity during positron emission tomography (PET) are described. Blood is withdrawn through 1-mm internal diameter tubing using an infusion pump which can be operated at rates varying from 0 to 600 ml/h. Activity in blood is measured by a 6-cm-thick bismuth germanate crystal connected to a photomultiplier tube and multichannel analyser (MCA) which are positioned within 6 cm lead shielding. Positioning of the tubing is an exact and simple procedure. The minimal readout time of the MCA is 1 s. Two independent energy windows can be set. Operation of the pump and MCA is fully controlled by a PC, i.e. sampling time, interval time and pump rate can be varied at any time during the PET scan by user-defined scripts. A number of characteristics of the new system were studied, such as sensitivity, dead time, linearity, effect of background radiation and pump rate as a function of input pressure. In addition, dispersion was measured as a function of pump rate. Finally, first clinical results were compared with manual samples. The sensitivity equalled 0.7 and 0.2 cps/Bq for 511- and 1022-keV 30% energy windows, respectively, and the system dead time was 500 ns. The system remained linear within 2% with activity concentrations up to 2.5 MBq/cc. Short-term reproducibility was better than 3% for a 1-h period. Long-term reproducibility was about 5% (ISD), which was mainly caused by variation in the diameter of the tubing. If the device was positioned in such a way that maximum shielding was directed towards the patient, the effects of background radiation from the patient on the measured activity concentration for clinically relevant conditions was minimal (<3%). Pump rate varied with input pressure, but remained constant for a given pressure. Dispersion constants smaller than 0.14 s(-1) were observed for pump rates higher than 300 ml/h, indicating that the system dispersion is small. Clinical data showed an excellent agreement to within 3% (ISD) between the results obtained with the new system and manual samples. With the continuous blood sampler radioactivity in blood can be measured accurately during the entire course of the PET scan. Furthermore, the system is fully programmable allowing adjustment of all parameters during a single PET scan.


Asunto(s)
Sangre/diagnóstico por imagen , Radiofármacos/sangre , Tomografía Computarizada de Emisión/instrumentación , Algoritmos , Humanos