Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Lasers Med Sci ; 39(1): 122, 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38703271

RESUMEN

Pulsed dye lasers are used effectively in the treatment of psoriasis with long remission time and limited side effects. It is, however, not completely understood which biological processes underlie its favorable outcome. Pulsed dye laser treatment at 585-595 nm targets hemoglobin in the blood, inducing local hyperthermia in surrounding blood vessels and adjacent tissues. While the impact of destructive temperatures on blood vessels has been well studied, the effects of lower temperatures on the function of several cell types within the blood vessel wall and its periphery are not known. The aim of our study is to assess the functionality of isolated blood vessels after exposure to moderate hyperthermia (45 to 60°C) by evaluating the function of endothelial cells, smooth muscle cells, and vascular nerves. We measured blood vessel functionality of rat mesenteric arteries (n=19) by measuring vascular contraction and relaxation before and after heating vessels in a wire myograph. To this end, we elicited vascular contraction by addition of either high potassium solution or the thromboxane analogue U46619 to stimulate smooth muscle cells, and electrical field stimulation (EFS) to stimulate nerves. For measurement of endothelium-dependent relaxation, we used methacholine. Each vessel was exposed to one temperature in the range of 45-60°C for 30 seconds and a relative change in functional response after hyperthermia was determined by comparison with the response per stimulus before heating. Non-linear regression was used to fit our dataset to obtain the temperature needed to reduce blood vessel function by 50% (Half maximal effective temperature, ET50). Our findings demonstrate a substantial decrease in relative functional response for all three cell types following exposure to 55°C-60°C. There was no significant difference between the ET50 values of the different cell types, which was between 55.9°C and 56.9°C (P>0.05). Our data show that blood vessel functionality decreases significantly when exposed to temperatures between 55°C-60°C for 30 seconds. The results show functionality of endothelial cells, smooth muscle cells, and vascular nerves is similarly impaired. These results help to understand the biological effects of hyperthermia and may aid in tailoring laser and light strategies for selective photothermolysis that contribute to disease modification of psoriasis after pulsed dye laser treatment.


Asunto(s)
Láseres de Colorantes , Animales , Ratas , Masculino , Láseres de Colorantes/uso terapéutico , Miocitos del Músculo Liso/fisiología , Miocitos del Músculo Liso/efectos de la radiación , Vasodilatación/efectos de la radiación , Vasodilatación/fisiología , Temperatura , Músculo Liso Vascular/efectos de la radiación , Músculo Liso Vascular/fisiología , Células Endoteliales/efectos de la radiación , Células Endoteliales/fisiología , Vasoconstricción/efectos de la radiación , Vasoconstricción/fisiología , Endotelio Vascular/efectos de la radiación , Ratas Wistar
2.
Dis Esophagus ; 31(6)2018 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-29701760

RESUMEN

Anastomotic leakage is one of the most severe complications after esophageal resection with gastric tube reconstruction. Impaired perfusion of the gastric fundus is seen as the main contributing factor for this complication. Optical modalities show potential in recognizing compromised perfusion in real time, when ischemia is still reversible. This review provides an overview of optical techniques with the aim to evaluate the (1) quantitative measurement of change in perfusion in gastric tube reconstruction and (2) to test which parameters are the most predictive for anastomotic leakage.A Pubmed, MEDLINE, and Embase search was performed and articles on laser Doppler flowmetry (LDF), near-infrared spectroscopy (NIRS), laser speckle contrast imaging (LSCI), fluorescence imaging (FI), sidestream darkfield microscopy (SDF), and optical coherence tomography (OCT) regarding blood flow in gastric tube surgery were reviewed. Two independent reviewers critically appraised articles and extracted the data: Primary outcome was quantitative measure of perfusion change; secondary outcome was successful prediction of necrosis or anastomotic leakage by measured perfusion parameters.Thirty-three articles (including 973 patients and 73 animals) were selected for data extraction, quality assessment, and risk of bias (QUADAS-2). LDF, NIRS, LSCI, and FI were investigated in gastric tube surgery; all had a medium level of evidence. IDEAL stage ranges from 1 to 3. Most articles were found on LDF (n = 12), which is able to measure perfusion in arbitrary perfusion units with a significant lower amount in tissue with necrosis development and on FI (n = 12). With FI blood flow routes could be observed and flow was qualitative evaluated in rapid, slow, or low flow. NIRS uses mucosal oxygen saturation and hemoglobin concentration as perfusion parameters. With LSCI, a decrease of perfusion units is observed toward the gastric fundus intraoperatively. The perfusion units (LDF, LSCI), although arbitrary and not absolute values, and low flow or length of demarcation to the anastomosis (FI) both seem predictive values for necrosis intraoperatively. SDF and OCT are able to measure microvascular flow, intraoperative prediction of necrosis is not yet described.Optical techniques aim to improve perfusion monitoring by real-time, high-resolution, and high-contrast measurements and could therefore be valuable in intraoperative perfusion mapping. LDF and LSCI use perfusion units, and are therefore subjective in interpretation. FI visualizes influx directly, but needs a quantitative parameter for interpretation during surgery.


Asunto(s)
Fuga Anastomótica/diagnóstico por imagen , Esofagectomía/efectos adversos , Fundus Gástrico/diagnóstico por imagen , Imagen de Perfusión/métodos , Estómago/cirugía , Anastomosis Quirúrgica/efectos adversos , Fuga Anastomótica/etiología , Medios de Contraste , Angiografía con Fluoresceína/métodos , Angiografía con Fluoresceína/estadística & datos numéricos , Fundus Gástrico/irrigación sanguínea , Humanos , Flujometría por Láser-Doppler/métodos , Flujometría por Láser-Doppler/estadística & datos numéricos , Microcirculación , Microscopía/métodos , Microscopía/estadística & datos numéricos , Imagen de Perfusión/estadística & datos numéricos , Periodo Posoperatorio , Valores de Referencia , Flujo Sanguíneo Regional , Espectroscopía Infrarroja Corta/métodos , Espectroscopía Infrarroja Corta/estadística & datos numéricos , Tomografía de Coherencia Óptica/métodos , Tomografía de Coherencia Óptica/estadística & datos numéricos
3.
Dis Esophagus ; 31(10)2018 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-29668909

RESUMEN

Compromised perfusion due to ligation of arteries and veins in esophagectomy with gastric tube reconstruction often (5-20%) results in necrosis and anastomotic leakage, which relate to high morbidity and mortality (3-4%). Ephedrine is used widely in anesthesia to treat intraoperative hypotension and may improve perfusion by the increase of cardiac output and mean arterial pressure (MAP). This study tests the effect of ephedrine on perfusion of the future anastomotic site of the gastric conduit, measured by laser speckle contrast imaging (LSCI). This prospective, observational, in vivo pilot study includes 26 patients undergoing esophagectomy with gastric tube reconstruction from October 2015 to June 2016 in the Academic Medical Center (Amsterdam). Perfusion of the gastric conduit was measured with LSCI directly after reconstruction and after an increase of MAP by ephedrine 5 mg. Perfusion was quantified in flux (laser speckle perfusion units, LSPU) in four perfusion locations, from good perfusion (base of the gastric tube) toward decreased perfusion (fundus). Intrapatient differences before and after ephedrine in terms flux were statistically tested for significance with a paired t-test. LSCI was feasible to image gastric microcirculation in all patients. Flux (LSPU) was significantly higher in the base of the gastric tube (791 ± 442) compared to the fundus (328 ± 187) (P < 0.001). After administration of ephedrine, flux increased significantly in the fundus (P < 0.05) measured intrapatients. Three patients developed anastomotic leakage. In these patients, the difference between measured flux in the fundus compared to the base of the gastric tube was high. This study presents the effect of ephedrine on perfusion of the gastric tissue measured with LSCI in terms of flux (LSPU) after esophagectomy with gastric tube reconstruction. We show a small but significant difference between flux measured before and after administration of ephedrine in the future anastomotic tissue (313 ± 178 vs. 397 ± 290). We also show a significant decrease of flux toward the fundus.


Asunto(s)
Efedrina/farmacología , Fundus Gástrico/irrigación sanguínea , Fundus Gástrico/diagnóstico por imagen , Imagen de Perfusión/métodos , Vasoconstrictores/farmacología , Adulto , Anciano , Anciano de 80 o más Años , Anastomosis Quirúrgica , Presión Arterial/efectos de los fármacos , Efedrina/administración & dosificación , Esofagectomía/efectos adversos , Esofagectomía/métodos , Unión Esofagogástrica/irrigación sanguínea , Unión Esofagogástrica/cirugía , Estudios de Factibilidad , Femenino , Fundus Gástrico/cirugía , Humanos , Ligadura/efectos adversos , Masculino , Microcirculación , Persona de Mediana Edad , Proyectos Piloto , Periodo Posoperatorio , Estudios Prospectivos , Procedimientos de Cirugía Plástica/métodos , Vasoconstrictores/administración & dosificación
4.
J Urol ; 196(6): 1749-1755, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27475968

RESUMEN

PURPOSE: Biopsies and cytology are cornerstones in the diagnosis of upper urinary tract urothelial carcinoma. However, a high rate of nondiagnostic biopsies, tumor upgrading and tumor up staging after nephroureterectomy has been observed. In this prospective in vivo study we evaluated the diagnostic accuracy of optical coherence tomography for the grading and staging of upper tract urothelial carcinoma. MATERIALS AND METHODS: A total of 26 patients underwent diagnostic ureterorenoscopy including biopsies and optical coherence tomography, followed by nephroureterectomy or segmental ureter resection. The sensitivity, specificity, negative predictive value and positive predictive value of upper tract urothelial carcinoma grading and staging by optical coherence tomography were evaluated according to the STARD (Standards for Reporting of Diagnostic Accuracy) initiative and the second stage (2a and 2b) of the IDEAL model. For tumor staging a 2×2 table for sensitivity and specificity was calculated. For tumor grading the Wilcoxon rank sum test was used to test µoct in low and high grade lesions followed by ROC analysis for sensitivity and specificity. RESULTS: In 83% the staging of lesions was in accordance with final histopathology. Sensitivity and specificity analysis for tumor invasion was 100% and 92%, respectively. Tumor size greater than 2 mm and inflammation were risks for false-positives. For low and high grade lesions median µoct was 2.1 and 3.0 mm-1, respectively (p <0.01). ROC analysis showed a sensitivity of 87% and a specificity of 90% using a µoct cutoff of 2.4 mm-1. CONCLUSIONS: This report describes optical coherence tomography as a real-time, intraoperatively diagnostic modality in the diagnostic evaluation of upper tract urothelial carcinoma. We confirmed the ability of optical coherence tomography to visualize, grade and stage urothelial carcinoma in the upper urinary tract.


Asunto(s)
Carcinoma de Células Transicionales/diagnóstico por imagen , Carcinoma de Células Transicionales/patología , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/patología , Tomografía de Coherencia Óptica , Neoplasias Ureterales/diagnóstico por imagen , Neoplasias Ureterales/patología , Anciano , Femenino , Humanos , Masculino , Clasificación del Tumor , Estadificación de Neoplasias , Estudios Prospectivos
5.
Graefes Arch Clin Exp Ophthalmol ; 254(1): 37-41, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25904293

RESUMEN

PURPOSE: The purpose is to evaluate the interdevice and interobserver agreements between the SL SCAN-1 (a FD-OCT integrated into a common slit lamp) and a standard stand-alone FD-OCT device (the Cirrus) with regard to the presence or absence of signs of leakage in the retina in patients with exudative AMD and treated with anti-VEGF. METHODS: Fifty-six patients, known to have exudative AMD and under treatment with anti-VEGF agents, were included. During a regular follow-up, OCT scans were made with the Cirrus (macular-cube pattern) and the SL SCAN-1 (radial-scan pattern). All scans were graded by two medical retina specialists for signs of intraretinal cysts, subretinal fluid accumulation, and thickening of the neurosensory retina. Presence of signs of leakage was concluded if one or more of the three signs were present. RESULTS: In 91 % of the patients, the observers made identical conclusions for both devices of the presence of signs of leakage, resulting in an interdevice Kappa coefficient of 0.87. For the scans with disagreement about the presence or absence of signs of leakage, positive and negative conclusions were equally distributed between both devices, and differences were restricted to more subtle signs of leakage. CONCLUSION: The interdevice Kappa coefficient of 0.87 shows a high agreement between the SL SCAN-1 and the Cirrus in grading signs of leakage in exudative AMD. OCT images play a pivotal role in the diagnosis and management of exudative diseases like AMD, and the SL SCAN-1 provides a very efficient approach to these patients with the integration of the FD-OCT device into a common slit lamp.


Asunto(s)
Barrera Hematorretinal/patología , Vasos Retinianos/patología , Lámpara de Hendidura , Líquido Subretiniano , Tomografía de Coherencia Óptica/métodos , Degeneración Macular Húmeda/diagnóstico , Anciano , Anciano de 80 o más Años , Inhibidores de la Angiogénesis/uso terapéutico , Permeabilidad Capilar , Exudados y Transudados , Femenino , Análisis de Fourier , Humanos , Inyecciones Intravítreas , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Tomografía de Coherencia Óptica/instrumentación , Factor A de Crecimiento Endotelial Vascular/antagonistas & inhibidores , Degeneración Macular Húmeda/tratamiento farmacológico
6.
Dis Esophagus ; 29(6): 505-12, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25951873

RESUMEN

Volumetric laser endomicroscopy (VLE) is a novel balloon-based optical coherence tomography (OCT) imaging technique that may improve detection of early neoplasia in Barrett's esophagus (BE). Most OCT studies lack a direct correlation between histology and OCT images. The aim is to investigate the optimal approach for achieving one-to-one correlation of ex-vivo VLE images of endoscopic resection (ER) specimens with histology. BE patients with and without early neoplasia underwent ER after delineating areas with electrocoagulation markers (ECM). After ER, specimens underwent additional ex-vivo marking with several different markers (ink, pin, Gold Probe) followed by ex-vivo VLE scanning. ER specimens were carefully sectioned into tissue blocks guided by the markers. Histology and VLE slides were considered a match if ≥ 2 markers were visible on both modalities and mucosal patterns aside from these markers matched on both histology and VLE. From 16 ER specimens 120 tissue blocks were sectioned of which 23 contained multiple markers. Fourteen histology-VLE matches were identified. ECMs and ink markers proved to be the most effective combination for matching. The last 6/16 ER specimens yielded 9/14 matches, demonstrating a learning curve due to methodological improvements in marker placement and tissue block sectioning. One-to-one correlation of VLE and histology is complex but feasible. The groundwork laid in this study will provide high-quality histology-VLE correlations that will allow further research on VLE features of early neoplasia in BE.


Asunto(s)
Adenocarcinoma/diagnóstico por imagen , Esófago de Barrett/diagnóstico por imagen , Neoplasias Esofágicas/diagnóstico por imagen , Microscopía Confocal/métodos , Tomografía de Coherencia Óptica/métodos , Adenocarcinoma/patología , Anciano , Esófago de Barrett/patología , Esófago de Barrett/cirugía , Detección Precoz del Cáncer , Resección Endoscópica de la Mucosa , Neoplasias Esofágicas/patología , Esofagoscopía , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad
7.
J Eur Acad Dermatol Venereol ; 29(4): 738-44, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25175118

RESUMEN

BACKGROUND: Cutaneous melanomas are diagnosed worldwide in 231,130 patients per year. The sensitivity and specificity of melanoma diagnosis expresses the need for an additional diagnostic method. Optical coherence tomography (OCT) has shown that it allows morphological (qualitative) description of image features and quantitative analysis of pathology related light scattering by means of the attenuation coefficient (µoct ). OBJECTIVE: We hypothesize that OCT images of nevi will differ qualitatively and quantitatively from melanomas. METHODS: Forty lesions from 33 consecutive patients were imaged with OCT. After data acquisition, excision was performed. Epidermal layer thickness was measured and values of µoct were extracted from 200 OCT images of pigmented lesions. RESULTS: Morphologically, absence of the lower border of the lesion was characteristic for melanoma (P = 0.02). Also, the µoct was different between benign and malignant lesions (P = 0.02). There were no differences in epidermal layer thickness of benign lesions and melanoma. CONCLUSION: Although this preliminary study comprised a small number of patients, quantitative analysis of OCT images in pigmented skin lesions give valuable additional information about lesions characteristics. When using the attenuation coefficient, it might be possible to distinguish between benign lesions and melanomas.


Asunto(s)
Melanoma/patología , Nevo Pigmentado/patología , Neoplasias Cutáneas/patología , Tomografía de Coherencia Óptica , Adulto , Epidermis/patología , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC
8.
Lasers Med Sci ; 29(3): 1297-305, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-23504262

RESUMEN

Optical coherence tomography (OCT) is an optical technique that measures the backscattering of near-infrared light by tissue. OCT yields in 2D and 3D images at micrometer-scale resolution, thus providing optical biopsies, approaching the resolution of histopathological imaging. The technique has shown to allow in vivo differentiation between benign and malignant epithelial tissue, through qualitative assessment of OCT images, as well as by quantitative evaluation, e.g., functional OCT. This study aims to summarize the principles of OCT and to discuss the current literature on the diagnostic value of OCT in the diagnosis of epithelial (pre)malignant lesions. The authors did a systematic search of the electronic databases PubMed and Embase on OCT in the diagnostic process of (pre)malignant epithelial lesions. OCT is able to differentiate between benign and (pre)malignant lesions of epithelial origin in a wide variety of tissues. In this way, OCT can detect skin cancers, oral, laryngeal, and esophageal cancer as well as genital and bladder cancer. OCT is an innovative technique which enables an optical biopsy of epithelial lesions. The incorporation of OCT in specific tools, like handheld and catheter-based probes, will further improve the implementation of this technology in daily clinical practice.


Asunto(s)
Epitelio/patología , Tomografía de Coherencia Óptica/métodos , Biopsia , Humanos , Neoplasias/patología
9.
Opt Express ; 21(24): 29145-56, 2013 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-24514466

RESUMEN

We use transmission and backscattering optical coherence tomography (OCT) to distinguish and quantify dependent and multiple scattering effects in turbid media. With transmission OCT the dependent scattering coefficients for a range of monodisperse silica particle suspensions are determined. An excellent agreement is observed between the measured dependent scattering coefficients and calculations based on Mie calculations, the Percus-Yevick radial distribution function, and coherent light scattering theory. Backscattering OCT measurements are fitted using the extended Huygens-Fresnel (EHF) model with the dependent scattering coefficients obtained from the transmission OCT measurements as input parameters. Good agreement between the EHF model and the backscattering OCT measurements is observed. For large particles, the rms scattering angle θrms obtained from the EHF fit is in fair agreement with θrms calculated from the transmission OCT data.


Asunto(s)
Algoritmos , Interpretación de Imagen Asistida por Computador/métodos , Nefelometría y Turbidimetría/métodos , Tomografía de Coherencia Óptica/métodos , Aumento de la Imagen/métodos , Luz , Nefelometría y Turbidimetría/instrumentación , Fantasmas de Imagen , Reproducibilidad de los Resultados , Dispersión de Radiación , Sensibilidad y Especificidad , Tomografía de Coherencia Óptica/instrumentación
10.
Opt Express ; 20(11): 11582-97, 2012 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-22714144

RESUMEN

We acquired images of breast malignancies using the Twente photoacoustic mammoscope (PAM), to obtain more information about the clinical feasibility and limitations of photoacoustic mammography. Results were compared with conventional imaging and histopathology. Ten technically acceptable measurements on patients with malignancies and two measurements on patients with cysts were performed. In the reconstructed volumes of all ten malignant lesions, a confined region with high contrast with respect to the background could be seen. In all malignant cases, the PA contrast of the abnormality was higher than the contrast on x-ray mammography. The PA contrast appeared to be independent of the mammographically estimated breast density and was absent in the case of cysts. Technological improvements to the instrument and further studies on less suspicious lesions are planned to further investigate the potential of PAM.


Asunto(s)
Neoplasias de la Mama/patología , Aumento de la Imagen/instrumentación , Aumento de la Imagen/métodos , Mamografía/instrumentación , Microscopía/instrumentación , Técnicas Fotoacústicas/instrumentación , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
11.
Opt Lett ; 37(23): 4820-2, 2012 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-23202057

RESUMEN

We designed, fabricated, and characterized an integrated-optics-based swept-source optical coherence tomography (SS-OCT) system in TriPleX technology. An external 1300 nm swept source is coupled to the chip, which contains waveguide structures for interferometric depth ranging and balanced detection. The complete OCT chip has a footprint of 0.4 cm × 1.8 cm. Light from the chip is focused onto the sample using an aspheric lens; the lateral resolution is 21±1 µm. OCT measurements, performed with a moveable mirror, demonstrate a sensitivity of -80 dB and imaging up to the maximum depth of 5.09 mm. Corrected for dispersion, the measured OCT axial resolution of 12.7±0.5 µm is in good agreement with the bandwidth limited resolution. Finally, we demonstrate cross-sectional OCT imaging of a multilayered tissue phantom over the whole depth range with the integrated-optics-based SS-OCT system.


Asunto(s)
Integración de Sistemas , Tomografía de Coherencia Óptica/instrumentación , Diseño de Equipo , Fantasmas de Imagen
12.
Lasers Surg Med ; 44(7): 541-9, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22886491

RESUMEN

BACKGROUND AND OBJECTIVE: Excision and histological assessment of the first draining node (sentinel lymph node) is a frequently used method to assess metastatic lymph node involvement related to cutaneous melanoma. Due to the time required for accurate histological assessment, nodal status is not immediately available to the surgeon. Hence, in case histological examination shows metastases, the patient has to be recalled to perform additional lymphadenectomy. To overcome these drawbacks we studied the applicability of photoacoustic tomographic imaging as an intra-operative modality for examining the status of resected lymph nodes. MATERIALS AND METHODS: In melanoma patients undergoing lymphadectomy for metastatic disease, six suspect lymph nodes were photoacoustically (PA) imaged using multiple wavelengths. Histopathologal examination showed three nodes without tumor cells (benign nodes) and three nodes with melanoma cells (malignant nodes). PA images were compared with histology and anatomical features were analyzed. In addition, PA spectral analysis was performed on areas of increased signal intensity. RESULTS: After correlation with histopathology, multiple areas containing melanoma cells could be identified in the PA images due to their increased response. Malignant nodes showed a higher PA response and responded differently to an increase in excitation wavelength than benign nodes. In addition, differences in anatomical features between the two groups were detected. CONCLUSIONS: Photoacoustic detection of melanoma metastases based on their melanin content proves to be possible in resected human lymph nodes. The amount of PA signal and several specific anatomical features seem to provide additional characteristics for nodal analysis. However, it is as yet preliminary to designate a highly accurate parameter to distinguish between malignant and benign nodes. We expect to improve the specificity of the technique with a future implementation of an adjusted illumination scheme and depth correction for photon fluence.


Asunto(s)
Cuidados Intraoperatorios/métodos , Escisión del Ganglio Linfático , Metástasis Linfática/diagnóstico , Melanoma/patología , Técnicas Fotoacústicas/métodos , Neoplasias Cutáneas/patología , Tomografía , Axila , Biomarcadores de Tumor/metabolismo , Humanos , Conducto Inguinal , Láseres de Estado Sólido , Melaninas/metabolismo , Melanoma/metabolismo , Melanoma/cirugía , Neoplasias Cutáneas/metabolismo , Neoplasias Cutáneas/cirugía
13.
Opt Express ; 19(7): 6131-40, 2011 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-21451637

RESUMEN

In this work we demonstrate measurements with optical coherence tomography (OCT) of the scattering phase function in the backward direction and the scattering anisotropy parameter g. Measurements of the OCT attenuation coefficient and the backscattering amplitude are performed on calibrated polystyrene microspheres with a time-domain OCT system. From these measurements the phase function in the backward direction is determined. The measurements are described by the single scattering model and match Mie calculations very well. Measurements on Intralipid demonstrate the ability to determine the g of polydisperse samples and, for Intralipid, g = 0.35 ± 0.03 is measured, which is well in agreement with g from literature. These measurements are validated using the Intralipid particle size distribution determined from TEM measurements. Measurements of g and the scattering phase function in the backward direction can be used to monitor changes in backscattering, which can indicate morphological changes of the sample or act as contrast enhancement mechanism.


Asunto(s)
Algoritmos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Tomografía de Coherencia Óptica/métodos , Anisotropía , Luz , Fantasmas de Imagen , Dispersión de Radiación
14.
J Microsc ; 244(2): 187-93, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21801179

RESUMEN

Gold nanoparticles are rapidly emerging for use in biomedical applications. Characterization of the interaction and delivery of nanoparticles to cells through microscopy is important. Scanning electron microscopes have the intrinsic resolution to visualize gold nanoparticles on cells. A novel sample preparation protocol was developed to enable imaging of cells and gold nanoparticles with a conventional below lens scanning electron microscopes. The negative influence of 'charging' on the quality of scanning electron microscopes' images could be limited by deposition of biological cells on a conductive (gold) surface. The novel protocol enabled high-resolution scanning electron microscopes' imaging of small clusters and individual gold nanoparticles on uncoated cell surfaces. Gold nanoparticles could be counted on cancer cells with automated routines.


Asunto(s)
Neoplasias de la Mama/química , Neoplasias de la Mama/ultraestructura , Nanopartículas del Metal/administración & dosificación , Microscopía Electrónica de Rastreo/métodos , Línea Celular , Femenino , Oro , Humanos
15.
Minerva Urol Nefrol ; 63(3): 213-25, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21993320

RESUMEN

In modern medicine the profound use of abdominal imaging has led to a dramatic change of presentation of renal tumors. Smaller tumors and therefore more benign masses are being discovered, and as systemic use of renal mass biopsies is not recommended by the general guidelines, an appropriate tool to assess the biology of renal tumors is highly desirable. Apart from new developments of currently applied diagnostic modalities, several research groups focus on the potential of optical diagnostic techniques to contribute to the diagnostic process of renal tumors. They use the interaction of light with biological tissue to gather information on the optical properties of a tissue sample and therefore providing information on the histological composition of this tissue in a non-invasive manner and in real-time. In this review we provide an overview of novel diagnostic techniques starting with the future of conventional diagnostics like Contrast-enhanced ultrasonography (CEUS) and positron emission tomography-computed tomography (PET-CT) followed by optical technologies that are potentially employed in the nearby future to improve the diagnostic process of renal tumors with a focus on optical diagnostic techniques.


Asunto(s)
Carcinoma de Células Renales/diagnóstico , Neoplasias Renales/diagnóstico , Carcinoma de Células Renales/diagnóstico por imagen , Diagnóstico por Imagen/métodos , Diagnóstico por Imagen/tendencias , Diseño de Equipo , Predicción , Humanos , Neoplasias Renales/diagnóstico por imagen , Imagen Multimodal , Tomografía de Emisión de Positrones , Espectrometría Raman/instrumentación , Espectrometría Raman/métodos , Tomografía de Coherencia Óptica/instrumentación , Tomografía de Coherencia Óptica/métodos , Tomografía Computarizada por Rayos X , Ultrasonografía
16.
Opt Express ; 18(4): 3883-92, 2010 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-20389399

RESUMEN

Doppler optical coherence tomography (OCT) is a technique to image tissue morphology and to measure flow in turbid media. In its most basic form, it is based on single (Mie) scattering. However, for highly scattering and dense media multiple and concentration dependent scattering can occur. For Intralipid solutions with varying scattering strength, the effect of multiple and dependent scattering on the OCT signal attenuation and Doppler flow is investigated. We observe a non-linear increase in the OCT signal attenuation rate and an increasingly more distorted Doppler OCT flow profile with increasing Intralipid concentration. The Doppler OCT attenuation and flow measurements are compared to Monte Carlo simulations and good agreement is observed. Based on this comparison, we determine that the single scattering attenuation coefficient micros is 15% higher than the measured OCT signal attenuation rate. This effect and the distortion of the measured flow profile are caused by multiple scattering. The non-linear behavior of the single scattering attenuation coefficient with Intralipid concentration is attributed to concentration dependent scattering.


Asunto(s)
Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Flujometría por Láser-Doppler/métodos , Tomografía de Coherencia Óptica/métodos , Luz , Dispersión de Radiación
17.
Phys Rev Lett ; 105(19): 198302, 2010 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-21231201

RESUMEN

We describe a new method to measure the decorrelation rate of the optical coherence tomography (OCT) magnitude simultaneously in space and time. We measure the decorrelation rate of the OCT magnitude in a Fourier-domain OCT system for a large range of translational diffusion coefficients by varying the sphere diameter. The described method uses the sensitivity advantage of Fourier-domain OCT over time-domain OCT to increase the particle diffusion imaging speed by a factor of 200. By coherent gating, we reduce the contribution of multiple scattering to the detected signal, allowing a quantitative study of diffusive particle dynamics in high concentration samples. We demonstrate that this technique is well suited to image diffusive particle dynamics in samples with a complex geometry as we measure the morphology and diffusive particle dynamics simultaneously with both high spatial and high temporal resolution.


Asunto(s)
Modelos Teóricos , Tomografía de Coherencia Óptica , Difusión , Análisis de Fourier , Luz , Dispersión de Radiación , Factores de Tiempo
18.
Front Oncol ; 10: 608, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32582525

RESUMEN

Extracellular vesicles (EVs) have great potential as biomarkers since their composition and concentration in biofluids are disease state dependent and their cargo can contain disease-related information. Large tumor-derived EVs (tdEVs, >1 µm) in blood from cancer patients are associated with poor outcome, and changes in their number can be used to monitor therapy effectiveness. Whereas, small tumor-derived EVs (<1 µm) are likely to outnumber their larger counterparts, thereby offering better statistical significance, identification and quantification of small tdEVs are more challenging. In the blood of cancer patients, a subpopulation of EVs originate from tumor cells, but these EVs are outnumbered by non-EV particles and EVs from other origin. In the Dutch NWO Perspectief Cancer-ID program, we developed and evaluated detection and characterization techniques to distinguish EVs from non-EV particles and other EVs. Despite low signal amplitudes, we identified characteristics of these small tdEVs that may enable the enumeration of small tdEVs and extract relevant information. The insights obtained from Cancer-ID can help to explore the full potential of tdEVs in the clinic.

19.
J Extracell Vesicles ; 8(1): 1643671, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31489142

RESUMEN

Extracellular vesicles (EVs) in plasma are commonly identified by staining with antibodies and generic dyes, but the specificity of antibodies and dyes to stain EVs is often unknown. Previously, we showed that platelet-depleted platelet concentrate contains two populations of particles >200 nm, one population with a refractive index (RI) < 1.42 that included the majority of EVs, and a second population with an RI > 1.42, which was thought to include lipoproteins. In this study, we investigated whether EVs can be distinguished from lipoproteins by the RI and whether the RI can be used to determine the specificity of antibodies and generic dyes used to stain plasma EVs. EVs and lipoproteins present in platelet-depleted platelet concentrate were separated by density gradient centrifugation. The density fractions were analyzed by Western blot and transmission electron microscopy, the RI of particles was determined by Flow-SR. The RI was used to evaluate the staining specificity of an antibody against platelet glycoprotein IIIa (CD61) and the commonly used generic dyes calcein AM, calcein violet, di-8-ANEPPS, and lactadherin in plasma. After density gradient centrifugation, EV-enriched fractions (1.12 to 1.07 g/mL) contained the highest concentration of particles with an RI < 1.42, and the lipoprotein-enriched fractions (1.04 to 1.03 g/mL) contained the highest concentration of particles with an RI > 1.42. Application of the RI showed that CD61-APC had the highest staining specificity for EVs, followed by lactadherin and calcein violet. Di-8-ANEPPS stained mainly lipoproteins and calcein AM stained neither lipoproteins nor EVs. Taken together, the RI can be used to distinguish EVs and lipoproteins, and thus allows evaluation of the specificity of antibodies and generic dyes to stain EVs.

20.
J Thromb Haemost ; 2018 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-29877049

RESUMEN

Essentials Standardization of extracellular vesicle (EV) measurements by flow cytometry needs improvement. Hollow organosilica beads were prepared, characterized, and tested as reference particles. Light scattering properties of hollow beads resemble that of platelet-derived EVs. Hollow beads are ideal reference particles to standardize scatter flow cytometry research on EVs. SUMMARY: Background The concentration of extracellular vesicles (EVs) in body fluids is a promising biomarker for disease, and flow cytometry remains the clinically most applicable method to identify the cellular origin of single EVs in suspension. To compare concentration measurements of EVs between flow cytometers, solid polystyrene reference beads and EVs were distributed in the first ISTH-organized interlaboratory comparison studies. The beads were used to set size gates based on light scatter, and the concentration of EVs was measured within the size gates. However, polystyrene beads lead to false size determination of EVs, owing to the mismatch in refractive index between beads and EVs. Moreover, polystyrene beads gate different EV sizes on different flow cytometers. Objective To prepare, characterize and test hollow organosilica beads (HOBs) as reference beads to set EV size gates in flow cytometry investigations. Methods HOBs were prepared with a hard template sol-gel method, and extensively characterized for morphology, size, and colloidal stability. The applicability of HOBs as reference particles was investigated by flow cytometry with HOBs and platelet-derived EVs. Results HOBs proved to be monodisperse with a homogeneous shell thickness. Two-angle light-scattering measurements by flow cytometry confirmed that HOBs have light-scattering properties similar to those of platelet-derived EVs. Conclusions Because the structure and light-scattering properties HOBs resemble those of EVs, HOBs with a given size will gate EVs of the same size. Therefore, HOBs are ideal reference beads with which to standardize optical measurements of the EV concentration within a predefined size range.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA