Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Vasc Surg ; 79(2): 405-411, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37913945

RESUMEN

BACKGROUND: Diagnosing peripheral arterial disease (PAD) can be challenging owing to medial arterial calcification (MAC) in patients with diabetes mellitus (DM) and chronic kidney disease (CKD). Current bedside tests, such as the ankle-brachial index and toe-brachial index, are often insufficient. The maximal systolic acceleration (ACCmax) is a velocimetric Doppler-derived parameter and could be a new promising test in the diagnostic workup of these patients. The primary aim of this study was to evaluate the diagnostic performance of the ACCmax to detect PAD. METHODS: A retrospective cohort study was performed in a tertiary referral hospital. Patients ≥18 years old with suspected PAD who underwent ACCmax measurement(s) along with computed tomography angiography of the abdominal aorta and lower extremities (reference test) were eligible for inclusion. ACCmax measurements of the posterior tibial artery, anterior tibial artery and peroneal artery were collected. Diagnostic performance was assessed by using sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and area under the curve (AUC). RESULTS: In total, 340 patients (618 limbs) were included. Approximately 40% suffered from DM and 30% had CKD. Diagnostic performance of the ACCmax to detect PAD for the posterior tibial artery showed a sensitivity of 90%, specificity of 93%, positive likelihood ratio of 12.83, and negative likelihood ratio of 0.11 (AUC, 0.953). For the anterior tibial artery, these results were 94%, 97%, 32.06, and 0.06 (same sequence as presented before) with an AUC of 0.984. The peroneal artery had a performance of 86%, 89%, 7.51, and 0.16, respectively (AUC, 0.893). Diagnostic accuracy of the ACCmax did not diminish in subgroup analysis for patients with DM or CKD. CONCLUSIONS: The ACCmax showed excellent diagnostic performance to detect PAD, independent of patients prone to medial arterial calcification.


Asunto(s)
Diabetes Mellitus , Enfermedad Arterial Periférica , Insuficiencia Renal Crónica , Humanos , Adolescente , Estudios Retrospectivos , Enfermedad Arterial Periférica/diagnóstico por imagen , Índice Tobillo Braquial , Insuficiencia Renal Crónica/diagnóstico
2.
Ann Vasc Surg ; 2024 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-39009120

RESUMEN

OBJECTIVES: The current study is an explanatory analysis of Dutch disciplinary law regarding aortic aneurysm and aortic dissection care. We aim to give insight in the way disciplinary judges rule on quality of care and to extract the lessons to be learned. METHODS: The online open-access governmental database, which includes all disciplinary rulings since 2010, was searched using search terms related to aortic aneurysm and dissection care. First, abstracts were screened for relevance. Thereafter, the full text of all remaining cases was read. Cases related to the diagnosis, treatment, or the postoperative phase of an aortic aneurysm or aortic dissection were included. Characteristics were registered and analyzed for quantitative assessment. Each case was summarized and coded for qualitative analysis. RESULTS: Forty-eight first-instance cases were included, of which 19 (40%) were founded. Reprimands (n=9) and warnings (n=7) were the prevailing measures. Seven out of 8 appeal cases filed by plaintiffs were unfounded. Six out of 9 appeals filed by defendants were adjudged and led to a less severe measure. Most cases concerned the subject of 'wrong treatment/wrong diagnosis' (75%). Whether not recognizing an aneurysm or dissection led to disciplinary culpability depended on case-specific circumstances, and much importance was attached to adequate documentation. In many complaints, an element of inadequate communication was recognized. CONCLUSIONS: Patient-involvement, clear communication, and implementing changes after a mistake could increase patient satisfaction, avert complaints, and prevent time-consuming trials. Maintaining adequate documentation and having knowledge on the analytical framework of the court is beneficial when confronted with a complaint.

3.
Ann Vasc Surg ; 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39025211

RESUMEN

OBJECTIVES: The accurate prediction of foot ulcer healing remains a major challenge in clinical practice. To date, no reliable bedside tests are available. The primary aim of this study was to determine the prognostic performance of the maximal systolic acceleration (ACCmax) to predict ulcer healing. Secondary objectives comprised the investigation of the prognostic accuracy in patients prone to medial arterial calcification, and to assess the potential risk of amputation. METHODS: A single-centre retrospective cohort study was conducted. Patients ≥ 18 years-old who presented with a new-onset ulcer (i.e. Fontaine IV and neuropathic ulcers) on the foot and underwent an ACCmax measurement at the hallux were included. Ulcer healing was defined as an intact skin with epithelialization after three or 12 months of follow-up. Prognostic performance was calculated by using sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR) and negative likelihood ratio (NLR). RESULTS: In total, 136 patients with 143 wounds were included. Almost half of the patients were diagnosed with diabetes mellitus (47%) and wound infection was present in 42% of cases. After three months of follow-up, a NPV of 97.9%, PLR of 3.25 and NLR of 0.19 was found when applying an ACCmax threshold of 0.5 m/s2. When looking at 12 months, these numbers were 85.6%, 2.72 and 0.50, respectively. Subgroup analysis for patients with diabetes mellitus and chronic kidney disease showed comparable results. The risk of amputation increased significantly when a measurement below 1.0 m/s2 was present (odd ratio 5.3, p = 0.010). CONCLUSIONS: ACCmax measurements at the hallux can have additional prognostic value in patients with foot ulcers. An ACCmax below 1.0 m/s2 is associated with non-healing of an ulcer and a higher risk of amputation, while higher ACCmax values are associated with limb salvage. Therefore, ACCmax could be used for grading ischemia in a wound classification system.

4.
Ann Vasc Surg ; 106: 71-79, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38615752

RESUMEN

BACKGROUND: The diagnosis of peripheral arterial disease (PAD) is commonly applied for symptoms related to atherosclerotic obstructions in the lower extremity, though its clinical manifestations range from an abnormal ankle-brachial index to critical limb ischemia. Subsequently, management and prognosis of PAD vary widely with the disease stage. A critical aspect is how this variation is addressed in administrative database-based studies that rely on diagnosis codes for case identification. The objective of this scoping review is to inventory the identification strategies used in studies on PAD that rely on administrative databases, to map the pros and cons of the International Classification of Diseases (ICD) codes applied, and to propose a first outline for a consensus framework for case identification in administrative databases. METHODS: Registry-based reports published between 2010 and 2021 were identified through a systematic PubMed search. Studies were subcategorized on the basis of the expressed study focus: claudication, critical limb ischemia, or general peripheral arterial disease, and the ICD code(s) applied for case identification mapped. RESULTS: Ninety studies were identified, of which 36 (40%) did not specify the grade of PAD studied. Forty-nine (54%) articles specified PAD grade studied. Five (6%) articles specified different PAD subgroups in methods and baseline demographics, but not in further analyses. Mapping of the ICD codes applied for case identification for studies that specified the PAD grade studied indicated a remarkable heterogeneity, overlap, and inconsistency. CONCLUSIONS: A large proportion of registry-based studies on PAD fail to define the study focus. In addition, inconsistent strategies are used for PAD case identification in studies that report a focus. These findings challenge study validity and interfere with inter-study comparison. This scoping review provides a first initiative for a consensus framework for standardized case selection in administrative studies on PAD. It is anticipated that more uniform coding will improve study validity and facilitate inter-study comparisons.

5.
Ann Vasc Surg ; 98: 87-101, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37355016

RESUMEN

BACKGROUND: Misinterpretation of patient preferences in perioperative education can lead to an undesired treatment decision. This explorative interview study presents differences in perspectives of patients and professionals on patient education in complex endovascular aortic aneurysm management. METHODS: Using convenience sampling, a cross-sectional interview study was performed among patients who were in various stages of the decision-making process for complex endovascular aortic repair. Five physicians were interviewed, representing the main providers of clinical information. Interviews were transcribed verbatim and analyzed inductively. RESULTS: Twelve patients (mean age 76.6 [standard deviation: 6.4], 83% male) were interviewed. Ten (83%) felt like they had no other realistic option besides undergoing surgery, whereas all professionals (5/5) stressed the importance of delicate patient selection. Five patients out of 10 (50%) who commented on their preferred decisional role considered the professional's advice as decisive. All but 1 patient (11/12) reported that the information was easy to understand, whereas 4 out of 5 professionals (80%) doubted whether patients could fully comprehend everything. Patients experienced a lack of information on the recovery process, although professionals stated that this was addressed during consultation. CONCLUSIONS: Several differences were found in the perspectives of patients and professionals on education in complex aortic aneurysm management. In order to optimize patient involvement in decision-making, professionals should be aware of these possible discrepancies and address them during consultation. Future research could focus on these differences in more detail by including more patients depending on their treatment and decision stages.


Asunto(s)
Aneurisma de la Aorta Abdominal , Procedimientos Endovasculares , Humanos , Masculino , Anciano , Femenino , Reparación Endovascular de Aneurismas , Estudios Transversales , Resultado del Tratamiento , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Educación del Paciente como Asunto , Procedimientos Endovasculares/efectos adversos
6.
Ann Surg ; 278(5): 815-822, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37497631

RESUMEN

OBJECTIVE: The aim of this time-trend analysis is to estimate long-term excess mortality and associated cardiovascular risk for abdominal aortic aneurysm (AAA) patients after elective repair while addressing the changes in AAA management and patient selection over time. BACKGROUND: Despite the intensification of endovascular aneurysm repair and cardiovascular risk management, Swedish population data suggest that AAA patients retain a persistently high long-term mortality after elective repair. The question is whether this reflects suboptimal treatment, a changing patient population over time, or a national phenomenon. METHODS: Nationwide time-trend analysis including 40,730 patients (87% men) following elective AAA repair between 1995 and 2017. Three timeframes were compared, each reflecting changes in the use of endovascular aneurysm repair and intensification of cardiovascular risk management. Relative survival analyses were used to estimate disease-specific excess mortality. Competing risk of death analysis evaluated the risk of cardiovascular versus noncardiovascular death. Sensitivity analysis evaluated the impact of changes in patient selection over time. RESULTS: Short-term excess mortality significantly improved over time. Long-term excess mortality remained high with a doubled mortality risk for women (relative excess risk=1.87, 95% CI: 1.73-2.02). Excess mortality did not differ between age categories. The risk of cardiovascular versus noncardiovascular death remained similar over time, with a higher risk of cardiovascular death for women. Changes in patient population (ie, older and more comorbid patients in the latter period) marginally impacted excess mortality (2%). CONCLUSIONS: Despite changes in AAA care, patients retain a high long-term excess mortality after elective repair with a persistent high cardiovascular mortality risk. In this, a clear sex - but no age - disparity stands out.

7.
J Endovasc Ther ; : 15266028231172400, 2023 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-37165946

RESUMEN

PURPOSE: To describe the concept of aortic elastic deformation (ED) measurement using duplex ultrasonography (DUS) as a tool for detection of high aneurysm sac pressure following endovascular aortic repair (EVAR). TECHNIQUE: High aneurysm sac pressure, with or without proven endoleak, will result in a less compressible aneurysm. Using the dual image function in B-mode of the DUS device and a standardized amount of applied probe pressure, ED can be measured. It is defined as the percentage of deformation of the aneurysm sac on probe pressure application. We hypothesize that less ED of the aneurysm sac can be related with high aneurysm sac pressure and possibly the presence of clinically relevant endoleak. In this note, we describe the technical details of the procedure and report on the applicability and results of ED measurements in the framework of aortic aneurysm and EVAR follow-up in a cohort of 109 patients. CONCLUSION: ED measurement is the first noninvasive pressure-based method in the quest to find a practical and reliable diagnostic tool to exclude high aneurysm sac pressure. In our patient cohort, patients with proven endoleak showed a smaller ED (less compressible), implying the presence of high aneurysm sac pressure. Further research should confirm whether ED measurement using DUS could reliably exclude endoleak after EVAR and further explore its potential for clinical application in EVAR follow-up. CLINICAL IMPACT: For the first time, a simple, fast, and inexpensive diagnostic tool is presented in this study for detecting high sac pressure following EVAR. High sac pressure is typically caused by clinically significant endoleaks, which can have significant consequences. Currently, computed tomography scanning is the most common method used to identify and characterize endoleaks. However, measuring elastic deformation may potentially replace more invasive and expensive modalities, such as the computed tomography in the future.

8.
J Endovasc Ther ; 30(3): 364-371, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-35236169

RESUMEN

PURPOSE: Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) is gaining popularity for the quantification of tissue perfusion, including foot perfusion in patients with lower extremity arterial disease (LEAD). However, the absolute fluorescence intensity is influenced by patient-and system-related factors limiting reliable and valid quantification. To enhance the quality of quantitative perfusion assessment using ICG NIR fluorescence imaging, normalization of the measured time-intensity curves seems useful. MATERIALS AND METHODS: In this cohort study, the effect of normalization on 2 aspects of ICG NIR fluorescence imaging in assessment of foot perfusion was measured: the repeatability and the region selection. Following intravenous administration of ICG, the NIR fluorescence intensity in both feet was recorded for 10 mins using the Quest Spectrum platform®. The effect of normalization on repeatability was measured in the nontreated foot in patients undergoing unilateral revascularization preprocedural and postprocedural (repeatability group). The effect of normalization on region selection was performed in patients without LEAD (region selection group). Absolute and normalized time-intensity curves were compared. RESULTS: Successful ICG NIR fluorescence imaging was performed in 54 patients (repeatability group, n = 38; region selection group, n = 16). For the repeatability group, normalization of the time-intensity curves displayed a comparable inflow pattern for repeated measurements. For the region selection group, the maximum fluorescence intensity (Imax) demonstrated significant differences between the 3 measured regions of the foot (P = .002). Following normalization, the time-intensity curves in both feet were comparable for all 3 regions. CONCLUSION: This study shows the effect of normalization of time-intensity curves on both the repeatability and region selection in ICG NIR fluorescence imaging. The significant difference between absolute parameters in various regions of the foot demonstrates the limitation of absolute intensity in interpreting tissue perfusion. Therefore, normalization and standardization of camera settings are essential steps toward reliable and valid quantification of tissue perfusion using ICG NIR fluorescence imaging.


Asunto(s)
Verde de Indocianina , Extremidad Inferior , Humanos , Estudios de Cohortes , Resultado del Tratamiento , Imagen Óptica/métodos , Perfusión
9.
Surg Endosc ; 37(9): 6824-6833, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37286750

RESUMEN

BACKGROUND: Indocyanine green near-infrared fluorescence bowel perfusion assessment has shown its potential benefit in preventing anastomotic leakage. However, the surgeon's subjective visual interpretation of the fluorescence signal limits the validity and reproducibility of the technique. Therefore, this study aimed to identify objective quantified bowel perfusion patterns in patients undergoing colorectal surgery using a standardized imaging protocol. METHOD: A standardized fluorescence video was recorded. Postoperatively, the fluorescence videos were quantified by drawing contiguous region of interests (ROIs) on the bowel. For each ROI, a time-intensity curve was plotted from which perfusion parameters (n = 10) were derived and analyzed. Furthermore, the inter-observer agreement of the surgeon's subjective interpretation of the fluorescence signal was assessed. RESULTS: Twenty patients who underwent colorectal surgery were included in the study. Based on the quantified time-intensity curves, three different perfusion patterns were identified. Similar for both the ileum and colon, perfusion pattern 1 had a steep inflow that reached its peak fluorescence intensity rapidly, followed by a steep outflow. Perfusion pattern 2 had a relatively flat outflow slope immediately followed by its plateau phase. Perfusion pattern 3 only reached its peak fluorescence intensity after 3 min with a slow inflow gradient preceding it. The inter-observer agreement was poor-moderate (Intraclass Correlation Coefficient (ICC): 0.378, 95% CI 0.210-0.579). CONCLUSION: This study showed that quantification of bowel perfusion is a feasible method to differentiate between different perfusion patterns. In addition, the poor-moderate inter-observer agreement of the subjective interpretation of the fluorescence signal between surgeons emphasizes the need for objective quantification.


Asunto(s)
Neoplasias Colorrectales , Cirugía Colorrectal , Humanos , Verde de Indocianina , Neoplasias Colorrectales/cirugía , Anastomosis Quirúrgica/métodos , Cirugía Colorrectal/métodos , Reproducibilidad de los Resultados , Fuga Anastomótica/prevención & control , Perfusión
10.
Ann Vasc Surg ; 94: 178-185, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37023926

RESUMEN

BACKGROUND: Nutcracker syndrome (NCS) is an uncommon syndrome that presents with signs and symptoms caused by compression of the left renal vein (LRV), whereas 'nutcracker phenomenon' is solely used to refer to the anatomical configuration without clinical symptoms. Treatment for NCS may include nonoperative management, open surgical intervention, and in some instances endovascular stenting. We present a single-center retrospective case series of patients who presented with NCS managed with open surgical interventions. METHODS: A single-center, retrospective review of patients managed from 2010-2021. We diagnosed NCS via a thorough clinical examination and additional cross-sectional imaging studies including magnetic resonance venography and/or computed tomography venography. For further confirmation of the diagnosis, duplex ultrasound was frequently combined with contrast venography. RESULTS: Thirty eight patients were included in our study from 2010-2021. Twenty one (55.3%) patients presented with symptoms including flank pain, abdominal pain, hematuria, and fatigue. The remaining 17 (44.7%) patients had nutcracker phenomenon. Within the group of patients diagnosed with NCS, 11 patients underwent LRV transposition. Symptoms related to NCS improved in 10 patients. Hematuria in 1 patient did not improve. CONCLUSIONS: Transposition of the LRV is an effective treatment for NCS. Nonoperative management is an option for those patients experiencing less severe or nonspecific clinical symptoms.


Asunto(s)
Hematuria , Síndrome de Cascanueces Renal , Humanos , Estudios Retrospectivos , Hematuria/etiología , Síndrome de Cascanueces Renal/complicaciones , Síndrome de Cascanueces Renal/diagnóstico por imagen , Síndrome de Cascanueces Renal/cirugía , Resultado del Tratamiento , Venas Renales/diagnóstico por imagen , Venas Renales/cirugía
11.
Ann Vasc Surg ; 93: 308-318, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36773932

RESUMEN

BACKGROUND: When introducing new techniques, attention must be paid to learning curve. Besides quantitative outcomes, qualitative factors of influence should be taken into consideration. This retrospective cohort study describes the quantitative learning curve of complex endovascular aortic repair (EVAR) in a nonhigh-volume academic center and provides qualitative factors that were perceived as contributors to this learning curve. With these factors, we aim to aid in future implementation of new techniques. METHODS: All patients undergoing complex EVAR in the Leiden University Medical Center (LUMC) between July 2013 and April 2021 were included (n = 90). Quantitative outcomes were as follows: operating time, blood loss, volume of contrast, hospital stay, major adverse events (MAE), 30-day mortality, and complexity. Patients were divided into 3 temporal groups (n = 30) for dichotomous outcomes. Regression plots were used for continuous outcomes. In 2017, the treatment team was interviewed by an external researcher. These interviews were reanalyzed for factors that contributed to successful implementation. RESULTS: Length of hospital stay (P = 0.008) and operating time (P = 0.010) decreased significantly over time. Fewer cardiac complications occurred in the third group (3: 0% vs. 2: 17% vs. 1: 17%, P = 0.042). There was a trend of increasing complexity (P = 0.076) and number of fenestrations (P = 0.060). No significant changes occurred in MAE and 30-day mortality. Qualitative factors that, according to the interviewees, positively influenced the learning curve were as follows: communication, mutual trust, a shared sense of responsibility and collective goals, clear authoritative structures, mutual learning, and team capabilities. CONCLUSIONS: In addition to factors previously identified in the literature, new learning curve factors were found (mutual learning and shared goals in the operating room (OR)) that should be taken into account when implementing new techniques.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Reparación Endovascular de Aneurismas , Factores de Riesgo , Estudios Retrospectivos , Aneurisma de la Aorta Abdominal/cirugía , Curva de Aprendizaje , Procedimientos Endovasculares/efectos adversos , Factores de Tiempo , Resultado del Tratamiento , Complicaciones Posoperatorias
12.
Ann Vasc Surg ; 97: 410-418, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37244480

RESUMEN

BACKGROUND: Vascular graft/endograft infection is a rare but life-threatening complication of cardiovascular surgery and remains a surgical challenge. Several different graft materials are available for the treatment of vascular graft/endograft infection, each having its own advantages and disadvantages. Biosynthetic vascular grafts have shown low reinfection rates and could be a potential second best after autologous veins in the treatment of vascular graft/endograft infection. Therefore, the aim of our study was to evaluate the efficacy and morbidity of Omniflow® II for the treatment of vascular graft/endograft infection. METHODS: A multicenter retrospective cohort study was performed to evaluate the use of Omniflow® II in the abdominal and peripheral region to treat vascular graft/endograft infection between January 2014 and December 2021. Primary outcome was recurrent vascular graft infection. Secondary outcomes included primary patency, primary assisted patency, secondary patency, all-cause mortality, and major amputation. RESULTS: Fifty-two patients were included with a median follow-up duration of 26.5 (10.8-54.8) months. Nine (17%) grafts were implanted in intracavitary position and 43 (83%) in peripheral position. Most grafts were used as femoral interposition (n = 12, 23%), femoro-femoral crossover (n = 10, 19%), femoro-popliteal (n = 8, 15%), and aorto-bifemoral (n = 8, 15%) graft. Fifteen (29%) grafts were implanted extra-anatomically and 37 (71%) in situ. Eight patients (15%) presented with reinfection during follow-up, most of these patients received an aorto-bifemoral graft (n = 3, 38%). Intracavitary vascular grafting had a 33% (n = 3) reinfection rate and peripheral grafting 12% (n = 5; P = 0.025). The estimated primary patencies at 1, 2, and 3 years were 75%, 72%, and 72% for peripherally located grafts and 58% (at all timepoints) for intracavitary grafts (P = 0.815). Secondary patencies at 1, 2, and 3 years were 77% (at all timepoints) for peripherally located prostheses and 75% (at all timepoints) for intracavitary prostheses (P = 0.731). A significantly higher mortality during follow-up was observed in patients who received an intracavitary graft compared to patients with a peripheral graft (P = 0.003). CONCLUSIONS: This study highlights the efficacy and safety of the Omniflow® II biosynthetic prosthesis for the treatment of vascular graft/endograft infection, in absence of suitable venous material, with acceptable reinfection, patency, and freedom of amputation prevalences, especially in replacing peripheral vascular graft/endograft infection. However, a control group with either venous reconstruction or another alternative graft is needed to make firmer conclusions.


Asunto(s)
Implantación de Prótesis Vascular , Infecciones Relacionadas con Prótesis , Enfermedades Vasculares , Humanos , Implantación de Prótesis Vascular/efectos adversos , Reinfección , Estudios Retrospectivos , Resultado del Tratamiento , Prótesis Vascular/efectos adversos , Enfermedades Vasculares/cirugía , Infecciones Relacionadas con Prótesis/cirugía , Grado de Desobstrucción Vascular
13.
Ann Vasc Surg ; 93: 283-290, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36642169

RESUMEN

BACKGROUND: The angiosome concept is defined as the anatomical territory of a source artery within all tissue layers. When applying this theory in vascular surgery, direct revascularization (DR) is preferred to achieve increased blood flow toward the targeted angiosome of the foot in patients with lower extremity arterial disease (LEAD). This study evaluates the applicability of the angiosome concept using quantified near-infrared (NIR) fluorescence imaging with indocyanine green (ICG). METHODS: This study included patients undergoing an endovascular- or surgical revascularization of the leg between January 2019 and December 2021. Preinterventional and postinterventional ICG NIR fluorescence imaging was performed. Three angiosomes on the dorsum of the foot were determined: the posterior tibial artery (hallux), the anterior tibial artery (dorsum of the foot) and the combined angiosome (second to fifth digit). The angiosomes were classified from the electronic patient records and the degree of collateralization was classified based on preprocedural computed tomography angiography and/or X-ray angiography. Fluorescence intensity was quantified in all angiosomes. A subgroup analysis based on endovascular or surgical revascularized angiosomes, and within critical limb threatening ischemia (CLTI) patients was performed. RESULTS: ICG NIR fluorescence measurements were obtained in 52 patients (54 limbs) including a total of 157 angiosomes (121 DR and 36 indirect revascularizations [IR]). A significant improvement of all perfusion parameters in both the directly and indirectly revascularized angiosomes was found (P-values between <0.001-0.007). Within the indirectly revascularized angiosomes, 90.6% of the scored collaterals were classified as significant. When comparing the percentual change in perfusion parameters between the directly and indirectly revascularized angiosomes, no significant difference was seen in all perfusion parameters (P-values between 0.253 and 0.881). Similar results were shown in the CLTI patients subgroup analysis, displaying a significant improvement of perfusion parameters in both the direct and indirect angiosome groups (P-values between <0.001 and 0.007), and no significant difference when comparing the percentual parameter improvement between both angiosome groups (P-values between 0.134 and 0.359). Furthermore, no significant differences were observed when comparing percentual changes of perfusion parameters in directly and indirectly revascularized angiosomes for both endovascular and surgical interventions (P-values between 0.053 and 0.899). CONCLUSIONS: This study proves that both DR and IR of an angiosome leads to an improvement of perfusion. This suggests that interventional strategies should not only focus on creating in-line flow to the supplying angiosome. One can argue that the angiosome concept is not applicable in patients with LEAD.


Asunto(s)
Verde de Indocianina , Recuperación del Miembro , Humanos , Resultado del Tratamiento , Recuperación del Miembro/métodos , Pie/irrigación sanguínea , Arterias Tibiales , Isquemia , Flujo Sanguíneo Regional
14.
Surgeon ; 21(1): 1-7, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35241372

RESUMEN

Surgery is a demanding field, requiring determination and emotional stability. This review explores the surgical personality, addressing international personality differences between surgical and non-surgical specialties. Across the globe, surgically-interested individuals (i.e., medical students, residents, surgeons) generally scored higher on conscientiousness, open mindedness, and extraversion, and lower on neuroticism compared to non-surgically-interested contemporaries. Extraversion was inversely correlated to burnout in surgical residents and open mindedness to reduced competence in giving feedback. Although additional region- and/or country-specific research is warranted, being or becoming a surgeon appears to correlate to personality traits such as high conscientiousness and low neuroticism.


Asunto(s)
Agotamiento Profesional , Cirujanos , Humanos , Personalidad , Cirujanos/psicología
15.
Ann Vasc Surg ; 78: 281-287, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34182113

RESUMEN

BACKGROUND: Patients with chronic limb threatening ischemia have a risk of undergoing a major amputation within 1 year of nearly 30% with a substantial risk of re-amputation since wound healing is often impaired. Quantitative assessment of regional tissue viability following amputation surgery can identify patients at risk for impaired wound healing. In quantification of regional tissue perfusion, near-infrared (NIR) fluorescence imaging using Indocyanine Green (ICG) seems promising. METHODS: This pilot study included adult patients undergoing lower extremity amputation surgery due to peripheral artery disease or diabetes mellitus. ICG NIR fluorescence imaging was performed within 5 days following amputation surgery using the Quest Spectrum PlatformⓇ. Following intravenous administration of ICG, the NIR fluorescence intensity of the amputation wound was recorded for 10 minutes. The NIR fluorescence intensity videos were analyzed and if a fluorescence deficit was observed, this region was marked as "low fluorescence." All other regions were marked as "normal fluorescence." RESULTS: Successful ICG NIR fluorescence imaging was performed in 10 patients undergoing a total of 15 amputations. No "low fluorescence" regions were observed in 11 out of 15 amputation wounds. In 10 out of these 11 amputations, no wound healing problems occurred during follow-up. Regions with "low fluorescence" were observed in 4 amputation wounds. Impaired wound healing corresponding to these regions was observed in all wounds and a re-amputation was necessary in 3 out of 4. When observing time-related parameters, regions with low fluorescence had a significantly longer time to maximum intensity (113 seconds vs. 32 seconds, P = 0.003) and a significantly lesser decline in outflow after five minutes (80.3% vs. 57.0%, P = 0.003). CONCLUSIONS: ICG NIR fluorescence imaging was able to predict postoperative skin necrosis in all four cases. Quantitative assessment of regional perfusion remains challenging due toinfluencing factors on the NIR fluorescence intensity signal, including camera angle, camera distance and ICG dosage. This was also observed in this study, contributing to a large variety in fluorescence intensity parameters among patients. To provide surgeons with reliable NIR fluorescence cut-off values for prediction of wound healing, prospective studies on the intra-operative use of this technique are required. The potential prediction of wound healing using ICG NIR fluorescence imaging will have a huge impact on patient mortality, morbidity as well as the burden of amputation surgery on health care.


Asunto(s)
Amputación Quirúrgica , Angiopatías Diabéticas/cirugía , Colorantes Fluorescentes/administración & dosificación , Verde de Indocianina/administración & dosificación , Isquemia/cirugía , Imagen de Perfusión , Enfermedad Arterial Periférica/cirugía , Piel/irrigación sanguínea , Espectroscopía Infrarroja Corta , Anciano , Enfermedad Crónica , Angiopatías Diabéticas/diagnóstico por imagen , Angiopatías Diabéticas/fisiopatología , Femenino , Humanos , Isquemia/diagnóstico por imagen , Isquemia/fisiopatología , Masculino , Persona de Mediana Edad , Necrosis , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Proyectos Piloto , Valor Predictivo de las Pruebas , Estudios Prospectivos , Flujo Sanguíneo Regional , Piel/patología , Supervivencia Tisular , Resultado del Tratamiento , Cicatrización de Heridas
16.
Vascular ; 30(5): 867-873, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34320878

RESUMEN

OBJECTIVES: Current diagnostic modalities for patients with peripheral artery disease (PAD) mainly focus on the macrovascular level. For assessment of tissue perfusion, near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) seems promising. In this prospective cohort study, ICG NIR fluorescence imaging was performed pre- and post-revascularization to assess changes in foot perfusion. METHODS: ICG NIR fluorescence imaging was performed in 36 patients with PAD pre- and post-intervention. After intravenous bolus injection of 0.1 mg/kg ICG, the camera registered the NIR fluorescence intensity over time on the dorsum of the feet for 15 min using the Quest Spectrum Platform®. Time-intensity curves were plotted for three regions of interest (ROI): (1) the dorsum of the foot, (2) the forefoot, and (3) the hallux. Time-intensity curves were normalized for maximum fluorescence intensity. Extracted parameters were the maximum slope, area under the curve (AUC) for the ingress, and the AUC for the egress. The non-treated contralateral leg was used as a control group. RESULTS: Successful revascularization was performed in 32 patients. There was a significant increase for the maximum slope and AUC egress in all three ROIs. The most significant difference was seen for the maximum slope in ROI 3 (3.7%/s to 6.6%/s, p < 0.001). In the control group, no significant differences were seen for the maximum slope and AUC egress in all ROIs. CONCLUSIONS: This study shows the potential of ICG NIR fluorescence imaging in assessing the effect of revascularization procedures on foot perfusion. Future studies should focus on the use of this technique in predicting favorable outcome of revascularization procedures.


Asunto(s)
Verde de Indocianina , Enfermedad Arterial Periférica , Humanos , Imagen Óptica/métodos , Perfusión , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Estudios Prospectivos , Procedimientos Quirúrgicos Vasculares
17.
J Endovasc Ther ; 28(6): 852-859, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34190633

RESUMEN

PURPOSE: Complex endovascular aortic repair (EVAR) procedures provide a treatment option for patients with aortic aneurysms involving visceral branches. Good technical results and short-term outcomes have been reported. Whether complex EVAR provides acceptable functional outcomes is not clear. The current study aims to describe postoperative functional outcomes in complex EVAR patients-an older and relatively frail patient group. MATERIALS AND METHODS: A single-center retrospective cohort study was performed, using data from a computerized database of consecutive patients who underwent complex EVAR in the Leiden University Medical Center (LUMC, The Netherlands) between July 2013 and September 2020. As of May 2017, patients scheduled for complex EVAR were referred to a geriatric care pathway to determine (Instrumental) Activities of Daily Living ((I)ADL) scores at baseline and, if informed consent was given, after 12 months. For the total patient group, adverse functional performance outcomes were: discharge to a nursing home and 12-month mortality. For the patients included in geriatric follow-up, the additional outcome was the incidence of functional decline (defined by a ≥2 point increase in (I)ADL-score) at 12-month follow-up. RESULTS: Eighty-two patients underwent complex EVAR, of which 68 (82.9%) were male. Mean age was 73.3 years (SD=6.3). Within 30 days postsurgery, 6 patients (7.3%) died. Mortality within 12 months for the total patient group was 14.6% (n=12). After surgery, no patients had to be discharged to a nursing home. Fifteen patients (18.3%) were discharged to a rehabilitation center. Twenty-three patients gave informed consent and were included in geriatric follow-up. Five patients (21.7%) presented functional decline 12 months postsurgery and 4 patients had died (17.4%) by that time. This means that 39.1% of the patients in the care pathway suffered an adverse outcome. CONCLUSION: To our knowledge, this is the only study that examined functional performance after complex EVAR, using a prospectively maintained database. No patients were newly discharged to a nursing home and functional performance results at 12 months are promising. Future multidisciplinary research should focus on determining which patients are most prone to deterioration of function, so that efforts can be directed toward preventing postoperative functional decline.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Actividades Cotidianas , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Humanos , Masculino , Rendimiento Físico Funcional , Complicaciones Posoperatorias/cirugía , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
18.
Ann Vasc Surg ; 71: 411-418, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32891744

RESUMEN

INTRODUCTION: An important step to reach a favorable outcome of abdominal endovascular aneurysm repair (EVAR) is preoperative sizing of the stent graft using computed tomography angiography (CTA) images of the abdominal aorta. A variety of costly image processing software options is available to obtain the necessary aortic measurements. A package that can be used for EVAR sizing is OsiriX Lite®-an open source, freely downloadable image processing option. This study assesses the concurrent validity of OsiriX Lite® when compared with commercially available 3Mensio Vascular® and Siemens Syngo.via®. METHODS: CTA scans of 20 patients that underwent EVAR for abdominal aneurysm were selected, 10 elective and 10 ruptured. For each scan, 6 observers determined 20 parameters needed for proper stent graft sizing, 2 using Osirix Lite®, 3 using 3Mensio Vascular®, and 1 using Siemens Syngo.via®. For each parameter, an intraclass correlation coefficient (ICC) and a P-value were calculated. Interrater agreement was interpreted using the Koo and Li Guidelines. Time needed to perform EVAR planning was compared. RESULTS: Overall interrater agreement between the 3 sizing options was found to be either "good" or "moderate" for 16 out of 20 parameters (80%). Time needed to perform EVAR planning was not significantly different for Osirix Lite® (568 sec) when compared with 3Mensio Vascular® (603 sec) or Siemens Syngo.via® (659 sec) with a P-value of 0.88. CONCLUSIONS: The authors conclude that Osirix Lite® is an accurate and time-effective image processing option for preoperative sizing of an EVAR stent graft when matched to 3Mensio Vascular® and Siemens Syngo.via®.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/cirugía , Aortografía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares/instrumentación , Interpretación de Imagen Radiográfica Asistida por Computador , Programas Informáticos , Stents , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Rotura de la Aorta/diagnóstico por imagen , Implantación de Prótesis Vascular/efectos adversos , Toma de Decisiones Clínicas , Procedimientos Endovasculares/efectos adversos , Humanos , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Diseño de Prótesis , Reproducibilidad de los Resultados , Estudios Retrospectivos , Resultado del Tratamiento
19.
Int J Mol Sci ; 22(2)2021 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-33451116

RESUMEN

Surgeons rely almost completely on their own vision and palpation to recognize affected tissues during surgery. Consequently, they are often unable to distinguish between different cells and tissue types. This makes accurate and complete resection cumbersome. Targeted image-guided surgery (IGS) provides a solution by enabling real-time tissue recognition. Most current targeting agents (tracers) consist of antibodies or peptides equipped with a radiolabel for Positron Emission Tomography (PET) and Single Photon Emission Computed Tomography (SPECT), magnetic resonance imaging (MRI) labels, or a near-infrared fluorescent (NIRF) dye. These tracers are preoperatively administered to patients, home in on targeted cells or tissues, and are visualized in the operating room via dedicated imaging systems. Instead of using these 'passive' tracers, there are other, more 'active' approaches of probe delivery conceivable by using living cells (macrophages/monocytes, neutrophils, T cells, mesenchymal stromal cells), cell(-derived) fragments (platelets, extracellular vesicles (exosomes)), and microorganisms (bacteria, viruses) or, alternatively, 'humanized' nanoparticles. Compared with current tracers, these active contrast agents might be more efficient for the specific targeting of tumors or other pathological tissues (e.g., atherosclerotic plaques). This review provides an overview of the arsenal of possibilities applicable for the concept of cell-based tracers for IGS.


Asunto(s)
Rastreo Celular/métodos , Medios de Contraste , Cirugía Asistida por Computador/métodos , Micropartículas Derivadas de Células/metabolismo , Humanos , Leucocitos/metabolismo , Imagen por Resonancia Magnética/métodos , Células Madre Mesenquimatosas/metabolismo , Nanopartículas/química , Tomografía de Emisión de Positrones/métodos , Cirugía Asistida por Computador/normas
20.
Int J Mol Sci ; 22(9)2021 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-33946583

RESUMEN

Molecular imaging of pathologic lesions can improve efficient detection of cancer and cardiovascular diseases. A shared pathophysiological feature is angiogenesis, the formation of new blood vessels. Endoglin (CD105) is a coreceptor for ligands of the Transforming Growth Factor-ß (TGF-ß) family and is highly expressed on angiogenic endothelial cells. Therefore, endoglin-based imaging has been explored to visualize lesions of the aforementioned diseases. This systematic review highlights the progress in endoglin-based imaging of cancer, atherosclerosis, myocardial infarction, and aortic aneurysm, focusing on positron emission tomography (PET), single-photon emission computed tomography (SPECT), magnetic resonance imaging (MRI), near-infrared fluorescence (NIRF) imaging, and ultrasound imaging. PubMed was searched combining the following subjects and their respective synonyms or relevant subterms: "Endoglin", "Imaging/Image-guided surgery". In total, 59 papers were found eligible to be included: 58 reporting about preclinical animal or in vitro models and one ex vivo study in human organs. In addition to exact data extraction of imaging modality type, tumor or cardiovascular disease model, and tracer (class), outcomes were described via a narrative synthesis. Collectively, the data identify endoglin as a suitable target for intraoperative and diagnostic imaging of the neovasculature in tumors, whereas for cardiovascular diseases, the evidence remains scarce but promising.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico por imagen , Endoglina/análisis , Neoplasias/diagnóstico por imagen , Animales , Enfermedades Cardiovasculares/cirugía , Humanos , Imagen por Resonancia Magnética/métodos , Neoplasias/cirugía , Imagen Óptica/métodos , Tomografía de Emisión de Positrones/métodos , Cirugía Asistida por Computador/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Ultrasonografía/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA