Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Arch Orthop Trauma Surg ; 144(6): 2859-2864, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38743114

RESUMEN

BACKGROUND: Total hip arthroplasty (THA) is the gold standard procedure for patients with end-stage osteoarthritis after failed conservative therapy. Digital templating is commonly employed in preoperative preparation for THA and contributes positively to its outcome. However, the impact of coxa valga and antetorta (CVA) configurations on stem size prediction accuracy remains not reported. Previous studies demonstrated that the size of the lesser trochanter (LT) can be used to determine femoral anteversion on pelvis radiographs. This study investigates the accuracy of preoperative digital templating in predicting stem size in patients with CVA undergoing cementless THA. METHODS: Preoperative radiographs of 620 patients undergoing cementless THA were retrospectively investigated. Radiographs were standardized with patients standing and the leg internally rotated by 15°. A CVA group was established including patients with a CCD angle greater than 140° and a lesser trochanter (LT) size of at least 10 mm for men and 8 mm for women. For the control group, radiographs with a CCD angle ranging from 125-135° and LT size 3-10 mm for men and 3-8 mm for women were selected. Preoperative templating was performed using mediCAD. To reduce confounding factors, case-control matching was carried out for BMI and body height. RESULTS: After case-control matching, a total of thirty-one matches were analyzed. Stem size was underestimated in 74% (23/31) in the CVA and 13% (4/31) in the control group (p < 0.001). Moreover, patients with CVA were more likely to be underestimated by two sizes compared to controls (p < 0.004). In contrast, the exact stem size was predicted more frequently in the control group (p < 0.001). CONCLUSION: Stem size in patients with a CVA configuration are at high risk of being underestimated when using digital templating. These findings can be valuable for guiding in intraoperative decisions and lowering the risk of complications associated with an undersized femoral component.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fémur , Prótesis de Cadera , Humanos , Femenino , Artroplastia de Reemplazo de Cadera/métodos , Masculino , Estudios de Casos y Controles , Anciano , Persona de Mediana Edad , Estudios Retrospectivos , Fémur/diagnóstico por imagen , Fémur/cirugía , Osteoartritis de la Cadera/cirugía , Osteoartritis de la Cadera/diagnóstico por imagen , Radiografía , Anciano de 80 o más Años
2.
J Orthop Sci ; 28(2): 385-390, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35058113

RESUMEN

BACKGROUND: Cementless glass ceramics containing apatite and wollastonite (AW-GC) bottom-coated titanium hip implants were developed; early excellent clinical and radiographic results have been reported previously. This study aimed to investigate the long-term clinical and radiographic outcomes in detail, and the wear rate of HXLPE. METHODS: We retrospectively evaluated 99 patients (117 hips) between November 2001 and December 2007. The survival rate was estimated using the Kaplan-Meier method. Hip joint function was evaluated using the Japanese Orthopaedic Association (JOA) score. The extent of radiographic signs was determined from the radiographs performed at the last follow-up. Polyethylene wear was measured using Martell's Hip Analysis Suite. We assessed the possible factors affecting the steady-state linear wear rate. RESULTS: The mean follow-up period was 14.8 ± 2.1 (10-18.6) years. The mean JOA score improved to 88.7 ± 9.4 (59-100) at the final follow-up from 47.8 ± 12.5 (17-76) before surgery. The overall survival rate with the end point of all-cause revision and wear-related revision was 99% and 100% respectively. There was no osteolysis or loosening of either the acetabular or femoral component. All hips were classified as having bone ingrowth fixation. The mean steady-state wear rate was 0.008 ± 0.025 mm/year. We found no significant correlation between the wear rate and age, body weight, body mass index, cup inclination and femoral head size. CONCLUSION: The combination of AW-GC bottom-coated implants and HXLPE showed excellent implant survival and wear resistance for 15 years.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Polietileno , Estudios Retrospectivos , Estudios de Seguimiento , Falla de Prótesis , Diseño de Prótesis
3.
J Arthroplasty ; 37(7S): S517-S523, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35240281

RESUMEN

BACKGROUND: Survivorship of total hip arthroplasty (THA) in younger patients is concerning given the inverse relationship between age and lifetime risk for revision. The purpose of this study is to determine if risk of revision has improved for patients aged 55 years or younger who undergo primary THA using modern polyethylene liners. METHODS: A retrospective review identified 2,461 consented patients (2,814 hips) with minimum 2-year follow-up who underwent primary THA at our institution between September 2007 and August 2014 using components from a single manufacturer (Zimmer Biomet), all with vitamin E-infused highly crosslinked polyethylene acetabular inserts. There were 561 patients (643 THA; 23%) aged 55 or younger and 1,900 (2,171 THA; 77%) older than 55. RESULTS: Mean follow-up was 5.0 years for both groups. There were more male patients in the younger (55%) than older (41%) group. Body mass index (BMI) was higher in younger patients independent of gender. Improvement in Harris hip score (HHS) was similar between groups. Kaplan-Meier survival to endpoint of all cause revision was similar between groups at 12 years (P = .8808) with 97.5% (95% CI: ±0.7%) for younger versus 97.1% (95% CI: ±0.6%) for older patients. Most frequent reason for revision overall was periprosthetic femoral fracture (21; 0.75%); univariate analysis revealed risk factors were female gender (P = .28) and age ≥65 years (P = .012). CONCLUSION: Use of modern polyethylene, such as vitamin E-stabilized highly cross-linked, liners during THA may improve survivorship in younger patients undergoing THA. Younger patients undergoing primary THA with highly cross-linked polyethylene liners had no increased rate of revision at mid-term follow-up.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Fracturas Periprotésicas , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Estudios de Seguimiento , Prótesis de Cadera/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Fracturas Periprotésicas/etiología , Polietileno , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento , Vitamina E
4.
BMC Musculoskelet Disord ; 22(1): 942, 2021 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-34758811

RESUMEN

BACKGROUND: Total hip arthroplasty (THA) for developmental dysplasia of the hip (DDH) is a complex procedure due to associated anatomical abnormalities. We studied the extent to which preoperative digital templating is reliable when performing cementless THA in patients with DDH. METHODS: We templated and compared the pre- and postoperative sizes of the acetabular and femoral components and the center of rotation (COR), and analysed the postoperative cup coverage, leg length discrepancy (LLD), and stem alignment in 50 patients (56 hips) with DDH treated with THA. RESULTS: The implant size exactly matched the template size in 42.9% of cases for the acetabular component and in 38.2% of cases for the femoral component, whereas the templated ±1 size was used in 80.4 and 81.8% of cases for the acetabular and femoral components, respectively. There were no statistically significant differences between templated and used component sizes among different DDH severity levels (acetabular cup: p = 0.30 under the Crowe classification and p = 0.94 under the Hartofilakidis classification; femoral stem: p = 0.98 and p = 0.74, respectively). There were no statistically significant differences between the planned and postoperative COR (p = 0.14 horizontally and p = 0.52 vertically). The median postoperative LLD was 7 (range 0-37) mm. CONCLUSION: Digital preoperative templating is reliable in the planning of cementless THA in patients with DDH.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación Congénita de la Cadera , Prótesis de Cadera , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Luxación Congénita de la Cadera/diagnóstico por imagen , Luxación Congénita de la Cadera/cirugía , Humanos , Estudios Retrospectivos
5.
BMC Musculoskelet Disord ; 22(1): 384, 2021 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-33894763

RESUMEN

BACKGROUND: Failed treatment of subtrochanteric fractures commonly leads to pain, limping, and poor limb function. Cementless total hip arthroplasty (THA) could serve as an efficient salvage procedure in such cases. This study aimed to evaluate the outcomes and complications of salvage THA in failed subtrochanteric fracture fixation cases. METHODS: From January 2001 to December 2017, cementless THA for failed treatment of subtrochanteric fractures was performed in 18 hips of 11 men and 7 women (average age, 74 years; age range, 57.0-89.0 years). Patients were followed up for clinical and radiological assessments in terms of implant survival and complications after a minimum follow-up of 2 years. The Wagner femoral stems (Zimmer, Warsaw, USA) were used in all 18 patients (100%), with the long-length stem (Wagner SL stem) and standard-length stem (Wagner cone stem) used in 11 and 7 patients, respectively. RESULTS: The mean follow-up period was 5.2 years (range: 2.2-10.8 years). The mean Harris hip score (HHS) was 38.2 (range: 24-56) preoperatively and 85.4 (range: 79-92) at the last follow-up. The mean postoperative limb length discrepancy was 6.4 mm (range: 4-9 mm). Only one patient underwent revision due to bone in-growth failure of the femoral stem. One patient had an episode of postoperative dislocation and was treated with closed reduction without reoccurrence. Delayed union of the fracture site occurred in one patient. Patients who were previously treated with an intramedullary nail had a significantly shorter surgical duration, lesser intraoperative blood loss, and fewer blood transfusions than those who were previously treated with plate and screws. Kaplan-Meier survival rate with an endpoint of revision was 94.4% (95% confidence interval 72.7-99.9) at 5 years. CONCLUSION: Our results indicate that cementless THA is a beneficial and effective procedure for salvaging the failed treatment of subtrochanteric fractures. The Wagner conical prosthesis has shown satisfactory function outcomes, stable fixation, and survival rate for these complex situations. However, attention should be paid to increased operation time, blood loss, and complications when performing THA for subtrochanteric fractures with failed fixation devices especially, plates and screws.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas de Cadera , Prótesis de Cadera , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Fémur/cirugía , Estudios de Seguimiento , Fracturas de Cadera/diagnóstico por imagen , Fracturas de Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
6.
J Arthroplasty ; 35(7): 1877-1884.e1, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32205004

RESUMEN

BACKGROUND: The distal radius is an optional site for evaluation of bone quality in postmenopausal women before cementless total hip arthroplasty. We hypothesized that dual-energy X-ray absorptiometry (DXA) and pulse-echo ultrasonometry of the distal radius may help discriminate subjects at high risk of femoral stem subsidence. METHODS: A prospective cohort of postmenopausal women with primary hip osteoarthritis underwent total hip arthroplasty with implantation of a parallel-sided femoral stem. Postoperative stem migration was measured using radiostereometric analysis. Preoperatively, subjects had multisite DXA measurement of bone mineral density (BMD) and pulse-echo ultrasonometry of the cortical-bone thickness. The diagnostic abilities of these methods to discriminate <2 mm and ≥2 mm femoral stem subsidence were tested. RESULTS: The accuracy of the distal radius BMD and cortical-bone thickness of the distal radius were moderate (area under the curve, 0.737 and 0.726, respectively) in discriminating between <2 mm and ≥2 mm stem subsidence. Women with low cortical-bone thickness of the radius were more likely (odds ratio = 6.7; P = .002) to develop stem subsidence ≥2 mm. These subjects had lower total hip BMD (P = .007) and reduced thickness of the medial cortex of the proximal femur (P = .048) with lower middle (P < .001) and distal (P = .004) stem-to-canal fill ratios. CONCLUSION: Femoral stem stability and resistance to subsidence are sensitive to adequate bone stock and unaltered anatomy. DXA and pulse-echo ultrasonometry of the distal radius may help discriminate postmenopausal women at high risk of stem subsidence.


Asunto(s)
Densidad Ósea , Radio (Anatomía) , Absorciometría de Fotón , Femenino , Fémur/diagnóstico por imagen , Fémur/cirugía , Humanos , Posmenopausia , Estudios Prospectivos , Radio (Anatomía)/diagnóstico por imagen , Radio (Anatomía)/cirugía
7.
J Arthroplasty ; 35(11): 3204-3207, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32571592

RESUMEN

BACKGROUND: Particularly in broach-only uncemented total hip arthroplasty, a narrow femoral canal presents a technical challenge. Traditionally such femurs have been considered to be Dorr A. To our knowledge, however, no study has reported on the relationship between isthmus width and the Dorr classification. METHODS: We reviewed 500 high-quality, hard copy radiographs. Dorr classification and isthmus canal width were measured using an electronic caliper by 5 independent observers with intraobserver and interobserver error calculated. For this study, we defined a narrow canal as being ≤10 mm at its narrowest point (isthmus). RESULTS: Eight percent (40) were Dorr A, 85% (424) Dorr B, and 7% (36) Dorr C. With respect to isthmus width for Dorr A, 63% (25) were ≤10 mm compared to just 13% (55) of Dorr B. However, overall because there were more Dorr B femurs, 69% of those with an isthmus of ≤10 mm were Dorr B. CONCLUSION: In this population, almost 70% of patients with an isthmus ≤10 mm were Dorr B, with only 30% being Dorr A. When using a broach-only technique, isthmus width should be routinely measured on the preoperative anteroposterior radiographs so as to alert the surgeon to potential problems.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Fémur/diagnóstico por imagen , Fémur/cirugía , Humanos , Radiografía , Estudios Retrospectivos
8.
J Arthroplasty ; 35(6S): S359-S363, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32209287

RESUMEN

BACKGROUND: Periprosthetic femur fracture remains a leading mode of early failure following cementless total hip arthroplasty (THA). The purpose of this study is to determine if a specific femoral morphology is associated with an increased risk of acute, periprosthetic fracture after cementless THA. METHODS: An institutional arthroplasty registry was used to identify 32 primary, cementless THAs revised for acute, postoperative periprosthetic fracture ("fracture" cohort) within 3 months of the index procedure. Patients were matched 1:2 to 64 THAs without fracture ("control" cohort) for age, body mass index, gender, and stem design. Preoperative radiographic measurements performed on anteroposterior pelvis and femur radiographs included the neck-shaft angle, endosteal width at 4 locations, and external cortical diameter at 2 locations. These measurements were used to calculate the morphological cortical index, canal flare index, canal calcar ratio, and canal bone ratio. Postoperative measurements included canal fill and stem alignment. Statistical analyses included clustered regressions, Fisher's exact test, and Student's t-test. RESULTS: The mean endosteal width at 10 cm distal to the lesser trochanter was greater in fracture patients, although not statistically significant (P = .1). However, this resulted in differences in the canal flare index (P = .03), canal calcar ratio (P = .03), and canal bone ratio (P = .03) between the 2 cohorts. These ratios indicate decreased meta-diaphyseal taper in fracture patients. Preoperative femoral neck-shaft angle was more varus in fracture patients (P = .04). CONCLUSION: Patients sustaining an acute, periprosthetic fracture with cementless femoral fixation after THA had thinner distal cortices and a decreased meta-diaphyseal taper.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Fracturas Periprotésicas , Artroplastia de Reemplazo de Cadera/efectos adversos , Fémur/diagnóstico por imagen , Fémur/cirugía , Prótesis de Cadera/efectos adversos , Humanos , Fracturas Periprotésicas/diagnóstico por imagen , Fracturas Periprotésicas/epidemiología , Fracturas Periprotésicas/etiología , Diseño de Prótesis , Estudios Retrospectivos
9.
Wiad Lek ; 73(12 cz 1): 2627-2633, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33577480

RESUMEN

OBJECTIVE: Introduction: Hip osteoarthritis is a disabling disease which become substantial health-related, social, and economic issue. The aim: To assess short term quality of life in male population with hip ostheoarthritis, after total hip arthroplasty. PATIENTS AND METHODS: Material and methods: 118 male patients were included in the study, age range from 31 to 79 year-old, who underwent total hip arthroplasty. Patients quality of life was assessed using questioners: abbreviated version of WHOQoL-BREF, as well as EQ-5D-5L, and SF-36 scale. Patients condition was investigated before surgery, 6 weeks and 6 months after the surgery. RESULTS: Results: The results from WHOQoL-BREF questionnaire demonstrated a statistically significant improvement of quality of life after the surgery - 6 weeks after the procedure by 4% and 21% (p<0.001), after 6 months by 13% and 42% (p<0.001), respectively. The most significant improvement was found in the somatic domain - by 5% after 6 weeks, and by 6% after 6 months (p<0.001). The quality of life according to the EQ-5D-5L questionnaire revealed statistically significant improvement after 6 weeks, by 18-24% (p<0.001), after 6 months by 41-48% (p<0.001). Substantial improvement was achieved in reducing pain and improving mobility. SF-36 questionnaire showed statistically significant improvement after 6 months from the surgery in both physical (by 44%), and mental condition (by 54%) (p<0.001). CONCLUSION: Conclusions: Improvement of the quality of life - mainly less severe pain and better mobility after total hip arthroplasty in the investigated group of men was proven in 6 weeks after the procedure, while the further progress was more noticeable 6 months after the procedure.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Osteoartritis de la Cadera , Adulto , Anciano , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/cirugía , Calidad de Vida , Reproducibilidad de los Resultados , Encuestas y Cuestionarios , Resultado del Tratamiento
10.
J Arthroplasty ; 34(1): 77-81, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30274947

RESUMEN

BACKGROUND: Although falling is becoming a major problem in the elderly, little is known about the long-term incidence of postoperative periprosthetic femoral fractures (PFF) after total hip arthroplasty (THA) using uncemented stems with a minimum follow-up of 26 years postoperatively. METHODS: In a consecutive series, the cumulative incidence of PFF after uncemented THA using a straight, collarless, tapered titanium stem was retrospectively reviewed in 354 hips (326 patients). After a mean follow-up of 28 (26-32) years postoperatively, 179 hips had died and 5 hips had been lost to follow-up. Kaplan-Meier survival analysis was used to estimate cumulative percentage probability of PFF. RESULTS: At final follow-up, a total of 27 fractures in 27 patients had occurred. In 15 hips, the stem had to be revised, and in 10 the fracture was treated by open reduction and internal fixation. Two patients declined further surgery. The cumulative percentage probability of PFF was 1.6% (95% confidence interval, 0.7 to 3.8) at 10 years and 13.2% (95% confidence interval, 8.5 to 20.2) at 29 years after primary THA. There was no association between the occurrence of fracture and gender, age at primary THA, cup revision, or canal fill index. CONCLUSION: Our findings indicate that PFF is the major mode of failure in the long term after uncemented THA using a tapered titanium stem. More research is needed to evaluate the reasons and risk factors for PFF after THA, thus providing better prophylaxis for those at risk and to compare the long-term incidence using different fixation methods and implants. LEVEL OF EVIDENCE: IV.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Fracturas del Fémur/epidemiología , Prótesis de Cadera/efectos adversos , Fracturas Periprotésicas/epidemiología , Complicaciones Posoperatorias/epidemiología , Accidentes por Caídas , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/instrumentación , Femenino , Fracturas del Fémur/etiología , Fémur , Fijación Interna de Fracturas , Alemania/epidemiología , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Fracturas Periprotésicas/etiología , Complicaciones Posoperatorias/etiología , Periodo Posoperatorio , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Titanio , Adulto Joven
11.
Int Orthop ; 43(12): 2715-2723, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-30706087

RESUMEN

PURPOSE: Uncemented stems in primary total hip replacement (THR) are concerning in the elderly due to ectatic femoral canals and cortical thinning resulting in higher incidence of fracture and subsidence in this population. To obviate this concern, the authors developed a technique using autologous impaction bone grafting to achieve a better fitting femoral stem. The aim of this randomised clinical trial was to assess the efficacy of the technique. METHODS: From 2013 to 2015, a total of 98 consecutive participants (100 primary THR procedures) were inducted into a single-institution, single-blinded, randomised clinical trial assessing, with radiostereometric analysis (RSA), the efficacy of autologous impaction bone grafting in uncemented primary THR compared with traditional uncemented primary THR technique. The primary outcome measure was femoral component migration using RSA. Secondary outcomes were post-operative proximal femoral bone density (using DEXA), hip function and quality of life using Oxford Hip Score (OHS) and Short Form-12 Health Survey (SF-12), hip pain and patient satisfaction. RESULTS: There was no difference in femoral component stability (p > 0.5) or calcar resorption between the Graft and No Graft Groups at two years. There was also no difference in OHS, SF-12, pain or satisfaction between the Graft and No Graft Groups at two years (p > 0.39). CONCLUSIONS: Autologous impaction bone grafting in uncemented primary THR has shown its short-term post-operative outcomes to be equivalent to standard uncemented technique, whilst offering a better fit in patients who are between femoral stem sizes. AUSTRALIAN CLINICAL TRIAL REGISTRATION NUMBER: ACTRN12618000652279.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/métodos , Trasplante Óseo/métodos , Femenino , Estudios de Seguimiento , Prótesis de Cadera , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida , Análisis Radioestereométrico , Trasplante Autólogo , Resultado del Tratamiento
12.
Eur J Orthop Surg Traumatol ; 29(3): 611-618, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30488136

RESUMEN

Studies over the past decade have reported that the use of highly porous sockets in total hip arthroplasty (THA) results in osseointegration and long-term implant stability. However, some reports have raised concerns regarding radiographic evidence of poor osseointegration with features of fibrous tissue ingrowth. The purpose of this study was to compare clinical and radiographic assessments of highly porous sockets with those of hydroxyapatite (HA)-coated porous sockets in THA for hip dysplasia (DDH) at least 1 year after surgery. A total of 127 patients (136 hips) were recruited for the study. Of these, 94 patients (101 hips) received highly porous sockets with clustered screws, while 33 patients (35 hips) received HA-coated porous sockets with clustered screws. There was no difference in clinical outcomes between the two types of sockets. All HA-coated porous sockets were radiographically stable, without radiolucent lines. Fifteen hips had radiolucent lines in two or three DeLee and Charnley zones, accompanied by sclerotic lines along the circumferences of the highly porous sockets. A significant difference in the height of the preoperative osteophyte of the anterior acetabular wall was observed between 86 hips with one or no radiolucent lines and 15 hips with two or three radiolucent lines. In cases of DDH with atrophic bone remodeling pattern, highly porous sockets with multiple screws may be used, while HA-coated porous sockets with clustered screws result in better sealing of the bone-component interface.


Asunto(s)
Durapatita , Luxación de la Cadera/cirugía , Articulación de la Cadera/diagnóstico por imagen , Prótesis de Cadera , Oseointegración , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera , Femenino , Estudios de Seguimiento , Luxación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Estudios Retrospectivos
13.
J Arthroplasty ; 33(4): 1126-1132, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29246717

RESUMEN

BACKGROUND: We questioned whether there was a radiographic difference in hip geometry reconstruction and implant fixation between 3 different cementless stem design concepts in patients with primary end-stage hip osteoarthritis. METHODS: We retrospectively evaluated the preoperative and postoperative radiographs by 2 independent and blinded reviewers in a series of 264 consecutive patients who had received either a straight double-tapered stem with 3 offset options (group A), a straight double-tapered stem with 2 shape options and modular necks (group B), and a bone-preserving curved tapered stem with 4 offset options (group C). The following parameters were assessed: acetabular, femoral and hip offset (HO), center of rotation height, leg length difference (LLD), and the endosteal fit of stem in the proximal femur (canal fill index). Group comparisons were performed using a one-way analysis of variance and subsequent pairwise comparisons (t-test). RESULTS: Postoperatively, HO could be equally restored with all 3 stem designs (P = .079). The postoperative LLD was smaller in group C compared to group A (0.8 mm [standard deviation, 3.2] vs 2.6 mm [standard deviation, 4.5], P = .002). Best combined reconstruction of HO and LLD could be achieved with the short curved stem by junior and senior surgeons (HO: -2.0 and -2.1 mm; LLD: 1.9 and 0.7 mm, respectively). The proximal and mid-height canal fill indexes were higher in groups B and C compared to group A, indicating a better metaphyseal and diaphyseal fit in the proximal femur (both P < .001). CONCLUSION: All 3 cementless stem designs allowed for good hip geometry reconstruction. Multiple shape and offset options allowed for a better metaphyseal stem fit and offered minor clinical advantages for leg length reconstruction. Modular necks did not provide reconstructive advantages in patients with primary hip osteoarthritis.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Fémur/cirugía , Prótesis de Cadera , Cadera/cirugía , Osteoartritis de la Cadera/cirugía , Procedimientos de Cirugía Plástica/métodos , Adulto , Anciano , Diseño de Equipo , Femenino , Cadera/anatomía & histología , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Periodo Posoperatorio , Diseño de Prótesis , Radiografía , Estudios Retrospectivos
14.
J Arthroplasty ; 33(9): 2899-2905, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29803578

RESUMEN

BACKGROUND: The primary aim of this study was to determine the clinical outcomes at 13-year follow-up of patients diagnosed with developmental dysplasia of the hip and subsequently treated with total hip arthroplasty (THA). The secondary aim was to investigate the effect of hip center location on clinical outcomes and polyethylene wear. METHODS: We reviewed data from a consecutive series of 104 patients (123 hips) from a single center. Patients were treated with THA with the high hip center (HHC) technique using cementless acetabular shells and highly cross-linked liners. Radiographs were collected preoperatively and through 13-year follow-up to assess degree of dysplasia (Crowe classification), component positioning, occurrence of bone resorption, and polyethylene wear. The Harris Hip Score (HHS) was administered at 4 and 13 years. RESULTS: No patients were lost to follow-up, and one was revised for femoral loosening. Radiolucency was seen in 20% of patients and was not associated with HHC (P = .560). No patients developed osteolysis. The wear rate was low for all patients (mean: 3 ± 19 µm/y) and not associated with HHC (P = .852). The median 13-year HHS was 91.9 (interquartile range: 84.8-97.0). There was a statistically significant decline from the 4- to 13-year HHS (P < .001) for the Crowe II-IV group, although 82% of these patients remained above 80 points at 13 years. The nondysplastic and Crowe I group showed no longitudinal change in HHS (P = .243). CONCLUSION: This cup design and highly cross-linked polyethylene liner combination demonstrates excellent clinical outcomes, similar to THA for primary osteoarthritis, through 13-year follow-up in patients with various degrees of developmental dysplasia of the hip and HHC reconstructions.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Luxación Congénita de la Cadera/cirugía , Prótesis de Cadera , Osteólisis/etiología , Polietileno/química , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Cementos para Huesos , Resorción Ósea , Femenino , Fémur , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Periodo Preoperatorio , Radiografía , Estudios Retrospectivos , Resultado del Tratamiento
15.
Int Orthop ; 42(1): 49-57, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28589313

RESUMEN

PURPOSE: The aim of this study is to quantitatively compare the difference in primary stability between collarless and collared versions of the same femoral stem. Specifically, we tested differences in subsidence and micromotion. METHODS: Collarless and collared versions of the same cementless femoral stem were implanted in two groups of six fresh-frozen cadaveric femurs. Each implanted femur was then subsequently tested for axial compressive and torsional loadings. A micro-CT based technique was applied to quantify implant subsidence and compute the map of local micromotion around the femoral stems. Micromotion of collarless and collared stems was compared in each Gruen zone. RESULTS: Subsidence was higher but not significantly (p = 0.352) with collarless (41.0 ± 29.9 µm) than with collared stems (37.0 ± 44.6 µm). In compression, micromotion was lower (p = 0.257) with collarless (19.5 ± 5 µm) than with collared stems (43.3 ± 33.1 µm). In torsion, micromotion was also lower (p = 0.476) with collarless (96.9 ± 59.8 µm) than collared stems (118.7 ± 45.0 µm). Micromotion was only significantly lower (p = 0.001) in Gruen zone 1 and for compression with collarless (7.0 ± 0.6 µm) than with collared stems (22.6 ± 25.5 µm). CONCLUSIONS: Primary stability was achieved for both stem designs, with a mean micromotion below the osseointegration threshold. Under loading conditions similar to those observed in normal daily activity and with good press-fit, the collar had no influence on subsidence or micromotion. Further studies are required to test the potential advantage of collar with higher loads, undersized stems, or osteoporotic femurs.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Fémur/cirugía , Prótesis de Cadera , Diseño de Prótesis/métodos , Microtomografía por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oseointegración , Presión , Diseño de Prótesis/efectos adversos , Falla de Prótesis/efectos adversos
16.
Int Orthop ; 42(7): 1683-1688, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29797167

RESUMEN

PURPOSE: The aim of this study was to compare the clinical outcomes of cementless total hip arthroplasty (THA) used for the treatment of osteonecrosis of the femoral head (ONFH) and for osteoarthritis (OA) at a mean ten years follow-up. METHODS: Case-control study of 78 patients (86 hips) who underwent THA for ONFH treatment (ONFH group). Patients were matched for age and sex to 78 patients (86 hips) who underwent THA for OA (OA group). We compared the clinical and patient-reported outcomes, implant survival rates, and rates of complications between the groups. RESULTS: There were no between-group differences in the Harris Hip Score and in the following patient-reported outcomes at the last follow-up: Japanese Orthopedic Association Hip-Disease Evaluation Questionnaire (JHEQ) pain and movement scores and the Physical Component Summary and Role/Social Component Summary scores of Short Form-36 (SF-36). However, the mental score of the JHEQ, the Mental Component Summary score of SF-36, and The Visual Analog Scale score for satisfaction were lower for the ONFH group than for OA group. The rate of complication was equivalent between the groups: 5% for the ONFH group and 3% for the OA group. The ten year implant survival rate was equivalent between the groups, at 97.5% for the ONFH group and 98.2% for the OA group. CONCLUSION: The functional outcomes, implant survival, and rate of complications for cementless THAs are comparable at a mean follow-up of ten years for ONFH and OA.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Necrosis de la Cabeza Femoral/cirugía , Osteoartritis de la Cadera/cirugía , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios de Casos y Controles , Femenino , Estudios de Seguimiento , Articulación de la Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Medición de Resultados Informados por el Paciente , Satisfacción del Paciente/estadística & datos numéricos , Falla de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
17.
BMC Musculoskelet Disord ; 18(1): 209, 2017 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-28532408

RESUMEN

BACKGROUND: Although the loss of bone mineral density (BMD) after total hip arthroplasty (THA) is a known problem, it remains unresolved. This study prospectively examined the effect of zoledronic acid (ZA) on bone turnover and BMD after cementless THA. METHODS: Between January 2010 and August 2011, 60 patients who underwent cementless THA were randomly assigned to receive either ZA infusion or placebo (0.9% normal saline only) postoperatively. ZA was administered at 2 day and 1 year postoperatively. Periprosthetic BMD in seven Gruen zones was assessed preoperatively and at given time points for 2 years. Serum markers of bone turnover, functional scales, and adverse events were recorded. RESULTS: Each group contained 27 patients for the final analysis. The loss of BMD across all Gruen zones (significantly in zones 1 and 7) up to 2 years postoperatively was noted in the placebo group. BMD was significantly higher in the ZA group than in the placebo group in Gruen zones 1, 2, 6, and 7 at 1 year and in Gruen zones 1, 6, and 7 at 2 years (p < 0.05). Compared with baseline measures of BMD, the ZA group had increased BMD in zones 1, 2, 4, 5, 6, and 7 at 1 year and in zones 1, 4, 6, and 7 at 2 years (p < 0.05). Serum bone-specific alkaline phosphatase and N-telopeptide of procollagen I levels were significantly increased at 6 weeks in the placebo group and decreased after 3 months in the ZA group. A transient decrease in osteocalcin level was found at 6 months in the ZA group. Functional scales and adverse events were not different between the two groups. CONCLUSIONS: The loss of periprosthetic BMD, especially in the proximal femur (zones 1 and 7), after cementless THA could be effectively reverted using ZA. In addition, bone turnover markers were suppressed until 2 years postoperatively following ZA administration. TRIAL REGISTRATION: Chang Gung Memorial Hospital Protocol Record 98-1150A3, Prevention of Periprosthetic Bone Loss After Total Hip Replacement by Annual Bisphosphonate Therapy, has been reviewed and will be made public on ClinicalTrials.gov. TRIAL REGISTRATION NUMBER: NCT02838121 . Registered on 19 July, 2016.


Asunto(s)
Artroplastia de Reemplazo de Cadera/tendencias , Conservadores de la Densidad Ósea/administración & dosificación , Remodelación Ósea/efectos de los fármacos , Difosfonatos/administración & dosificación , Imidazoles/administración & dosificación , Osteoporosis/diagnóstico por imagen , Osteoporosis/tratamiento farmacológico , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Remodelación Ósea/fisiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteoporosis/etiología , Estudios Prospectivos , Ácido Zoledrónico
18.
J Arthroplasty ; 32(1): 161-165.e1, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27444850

RESUMEN

BACKGROUND: Cross-linked polyethylene (XLPE) acetabular liners used in cementless total hip arthroplasty (THA) have demonstrated better wear resistance at 10 years compared with conventional polyethylene (CPE) liners. No clinical studies have compared XPLE to CPE liners beyond 10 years. METHODS: We performed a 15-year retrospective cohort study on cementless THA performed in patients with developmental hip dysplasia to measure the differences in polyethylene wear rates and the presence of osteolysis. Twenty-four THAs with XLPE and 17 THAs with CPE were evaluated. The mean age of patients was 55.9 years (41-68) in the XLPE group and 54.4 years (40-67) in the CPE group. The mean follow-up period was 15.1 years (13.9-16.1) in the XLPE group and 15.2 years (14.5-16.0) in the CPE group. RESULTS: The XLPE group had a significantly lower wear rate at 5 and 10 years compared with the CPE group; however, no significant difference was found at 15 years (XLPE group, 0.040 mm/y; CPE group, 0.034 mm/y). In addition, the incidence of osteolysis did not differ significantly between the groups. However, the incidence of excessive wear between 10 and 15 years after surgery in the XLPE group was significantly higher than that in the CPE group. CONCLUSION: XLPE demonstrated no advantage in the wear rate or the incidence of osteolysis at 15 years, despite having superior wear resistance up to 10 years. It is concerning that the incidence of excessive wear was higher in the XLPE group between 10 and 15 years, and this finding should alert the arthroplasty community to this possible problem with the more highly cross-linked polyethylene.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Luxación Congénita de la Cadera/cirugía , Osteólisis/etiología , Polietileno/efectos adversos , Falla de Prótesis/etiología , Acetábulo/cirugía , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Prótesis de Cadera/efectos adversos , Humanos , Incidencia , Japón/epidemiología , Masculino , Persona de Mediana Edad , Osteólisis/epidemiología , Diseño de Prótesis , Estudios Retrospectivos
19.
J Arthroplasty ; 32(3): 1048-1053, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27919579

RESUMEN

BACKGROUND: There are limited studies to evaluate long-term clinical and radiographic outcomes of alumina delta ceramic-on-ceramic bearings in cementless total hip arthroplasty (THA). The purpose of this study was to evaluate the clinical and radiographic results, prevalence of osteolysis, squeaking, and fracture of ceramic material associated with the use of the alumina delta ceramic-on-alumina delta ceramic bearing in cementless THA in patients aged <50 years. METHODS: We reviewed the cases of 277 patients (334 hips) who underwent a cementless THA using alumina delta ceramic-on-alumina delta ceramic when they were 50 years or younger at the time of surgery. Demographic data; Harris Hip Score; Western Ontario McMaster Universities Osteoarthritis Index; and University of California, Los Angeles activity score were recorded. Radiographic and computerized tomographic evaluations were used to evaluate implant fixation and osteolysis. Squeaking sound and ceramic fracture were documented. The mean follow-up was 7.8 years (range, 6-9). RESULTS: The mean postoperative Harris Hip Score, Western Ontario and McMaster Universities Osteoarthritis Index score, University of California, Los Angeles activity score were 93 points, 15 points, and 8.6 points, respectively. Two patients had thigh pain (grade 7 points). All acetabular components and all but 2 femoral components were well fixed. Thirty-three hips (10%) exhibited clicking sound, and 2 hips (0.6%) exhibited squeaking sound. No hip had osteolysis or ceramic head or liner fracture. CONCLUSION: Our minimum 6-year follow-up results with the use of alumina delta ceramic-on-alumina delta ceramic bearings in patients aged <50 years suggest that cementless THA provides a high rate of survivorship without evidence of osteolysis or fracture of ceramic material.

20.
J Arthroplasty ; 32(3): 872-876, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27776903

RESUMEN

BACKGROUND: Total hip arthroplasty (THA) provides a successful salvage option for failed acetabular fractures. The complexity of arthroplasty for a failed acetabular fracture will depend on the fracture pattern and the initial management of the fracture. Our objective was to compare the midterm outcome of THA between patients who presented with failed acetabular fractures following initial surgical or nonsurgical treatment. METHODS: Forty-seven patients underwent cementless THA ± acetabular reconstruction following failed treatment of acetabular fractures. Twenty-seven were initially treated by surgery (group A) and 20 had nonsurgical treatment (group B). Intraoperative measures, preoperative and follow-up clinical, radiological, and functional outcomes were compared between the 2 groups. RESULTS: The mean surgical time, blood loss, and need for blood transfusion were significantly less in group A (P < .05). Acetabular reconstruction to address cavitary or segmental defects was needed in a significantly higher number of patients in group B (P = .006). Significant improvement in modified Merle d'Aubigne and Oxford scores was seen postsurgery in both groups. Acetabular component survival with aseptic loosening as end point was 98%. Overall survival rate with infection, revision, or loosening as end point was 93% at a mean follow-up of 7 years ± 17 months. CONCLUSION: THA for a failed acetabular fracture is greatly facilitated by initial surgical treatment. Although functional results and survivorship were similar in both groups, failed nonsurgical treatment in complex fractures is associated with migrated femoral head and extensive acetabular defects requiring complex acetabular reconstruction.


Asunto(s)
Acetábulo/lesiones , Artroplastia de Reemplazo de Cadera , Fijación Interna de Fracturas , Fracturas Óseas/cirugía , Acetábulo/cirugía , Adulto , Femenino , Lesiones de la Cadera/cirugía , Articulación de la Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Reoperación , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA