RESUMEN
This work describes a dynamic magnetic resonance imaging (MRI) technique for local scanning of the human body with use of a handheld receive coil or coil array. Real-time MRI is based on highly undersampled radial gradient-echo sequences with joint reconstructions of serial images and coil sensitivity maps by regularized nonlinear inversion (NLINV). For this proof-of-concept study, a fixed slice position and field-of-view (FOV) were predefined from the operating console, while a local receive coil (array) is moved across the body-for the sake of simplicity by the subject itself. Experimental realizations with a conventional 3 T magnet comprise dynamic anatomic imaging of the head, thorax and abdomen of healthy volunteers. Typically, the image resolution was 0.75 to 1.5 mm with 3 to 6 mm section thickness and acquisition times of 33 to 100 ms per frame. However, spatiotemporal resolutions and contrasts are highly variable and may be adjusted to clinical needs. In summary, the proposed FLASHlight MRI method provides a robust acquisition and reconstruction basis for future diagnostic strategies that mimic the usage of ultrasound. Necessary extensions for this vision require remote control of all sequence parameters by a person at the scanner as well as the design of more flexible gradients and magnets.
RESUMEN
Aims: Coronary microvascular dysfunction (CMD) is related to the pathophysiology, mortality, and morbidity of heart failure with preserved ejection fraction (HFpEF). A novel single-photon emission computed tomography (SPECT) camera with cadmium zinc telluride (CZT) detectors allows for the quantification of absolute myocardial blood flow and myocardial flow reserve (MFR) in patients with coronary artery disease. However, the potential of CZT-SPECT assessing for CMD has never been evaluated in patients with HFpEF. Methods and results: The clinical records of 127 consecutive patients who underwent dynamic CZT-SPECT were retrospectively reviewed. Rest and stress scanning were started simultaneously with 3 and 9â MBq/kg of 99mTc-sestamibi administration, respectively. Dynamic CZT-SPECT imaging data were analysed using a net-retention model with commercially available software. Transthoracic echocardiography was performed in all patients. The MFR value was significantly lower in the HFpEF group (mean ± SEM = 2.00 ± 0.097) than that in the non-HFpEF group (mean ± SEM = 2.74 ± 0.14, P = 0.0004). A receiver operating characteristic analysis indicated that if a cut-off value of 2.525 was applied, MFR could efficiently distinguish HFpEF from non-HFpEF. Heart failure with preserved ejection fraction had a consistently low MFR, regardless of the diastolic dysfunction score. Heart failure with preserved ejection fraction patients with MFR values lower than 2.075 had a significantly higher incidence of heart failure exacerbation. Conclusion: Myocardial flow reserve assessed by CZT-SPECT was significantly reduced in patients with HFpEF. A lower MFR was associated with a higher hospitalization rate in these patients. Myocardial flow reserve assessed by CZT-SPECT has the potential to predict future adverse events and stratify the severity of disease in patients with HFpEF.
RESUMEN
A detailed understanding of foot morphology can enable the design of more comfortable and better fitting footwear. However, foot morphology varies widely within the population, and changes dynamically as the foot is loaded during stance. This study presents a parametric statistical shape model from 4D foot scans to capture both the inter- and intra-individual variability in foot morphology. Thirty subjects walked on a treadmill while 4D scans of their right foot were taken at 90 frames-per second during stance phase. Each subject's height, weight, foot length, foot width, arch length, and sex were also recorded. The 4D scans were all registered to a common high-quality foot scan, and a principal component analysis was done on all processed 4D scans. Elastic-net linear regression models were built to predict the principal component scores, which were then inverse transformed into 4D scans. The best performing model was selected with leave-one-out cross-validation. The chosen model predicts foot morphology across stance phase with a root-mean-square error of 5.2 ± 2.0 mm and a mean Hausdorff distance of 25.5 ± 13.4 mm. This study shows that statistical shape modeling can be used to predict dynamic changes in foot morphology across the population. The model can be used to investigate and improve foot-footwear interaction, allowing for better fitting and more comfortable footwear.
Asunto(s)
Pie , Imagenología Tridimensional , Pie/diagnóstico por imagen , Humanos , Modelos Estadísticos , Análisis de Componente Principal , CaminataRESUMEN
Antibody-drug conjugates (ADC) are made up of three components: (1) a mAb specific to cells of choice, (2) a small molecule with desired end goal, and (3) a linker to covalently link drug molecule to the antibody. Bringing together the mAb, drug molecule, and the linker results in the formation of an immunoconjugate designed to selectively deliver the drug molecule to a cell of interest. Synergic effects of the mAb and drug molecule lead to destroying the target tumor cells while leaving the normal cells unharmed. However, the development of ADCs is associated with challenges due to the heterogeneity of the ADC molecules created from the conjugation process. Addition of the linker and drug moieties during processing as well as the hydrophobicity of the drug itself can lead to structural changes that may affect the stability and functional profile of the conjugated molecule. Furthermore, linkers site of attachment plays a major role in determining the conformational and colloidal properties of the ADCs. In this chapter, several characterization methods are introduced to determine the biophysical characteristics of the ADC. Protocols, data analysis as well as notes for circular dichroism, intrinsic fluorescence, ANS fluorescence, differential scanning calorimetry, and dynamic scanning fluorimetry are outlined in detail.
Asunto(s)
Fenómenos Químicos , Inmunoconjugados/análisis , Inmunoconjugados/química , Rastreo Diferencial de Calorimetría , Dicroismo Circular , Análisis de Datos , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Análisis EspectralRESUMEN
The recently proposed digital reconfigurable metasurfaces make it possible to manipulate electromagnetic (EM) waves flexibly. However, most existing reconfigurable metasurfaces can only exhibit a relatively single performance in the spatial domain. Here, we propose a general frequency- and spatial-domain reconfigurable metasurface (FSRM) that can manipulate the EM waves and realize reconfigurable functions in multifrequency bands. In the frequency domain, FSRM can convert different linearly polarized (LP) incident waves into left- and right-hand circularly polarized reflected waves, in which PIN diodes are used to switch the polarization conversions in different frequency bands. When the polarization direction of the incident LP wave is 45° from the +x-axis, the FSRM modulates the incident waves as a 1-bit programmable metasurface in the spatial domain. Two-dimensional beam scanning, vortex beams with orbital angular momentums, and specific beams with desired transmission directions are demonstrated via real-time adjustment of the digital coding state. To validate the modulation methodology, an FSRM prototype is fabricated and measured, which could respond to different functions for different polarization incidences. The measured results agree well with the theoretical analyses. The proposed FSRM will provide new opportunities for smart material designs.
RESUMEN
Thermoresponsive nanoparticles are promising smart materials for many applications. However, a rational design for applications requires a deeper understanding and experimental verification of the various parameters that influence the thermoresponsiveness of the spherical polymer brushes that define most of such nanomaterials. Therefore, we investigate superparamagnetic iron oxide nanoparticles (SPION) grafted with poly(2-isopropyl-2-oxazoline) (6â»33 kg mol-1) by temperature-cycled dynamic light scattering and differential scanning calorimetry. The grafting of dense spherical polymer brushes leads to lower aggregation temperatures and transition enthalpies when compared with the free polymer. The transition enthalpy and temperature depend on the polymer shell size and structure. The addition of kosmotropic salts decreases the aggregation temperature following the Hofmeister series.
RESUMEN
Nanoparticles grafted with a dense brush of hydrophilic polymers exhibit high colloidal stability. However, reversible aggregation can be triggered by an increase in temperature if the polymer is thermoresponsive, as the polymer shell partly loses its hydration. We investigate the role of nanoparticle curvature on the critical solution temperature (CST) of grafted poly(2-isopropyl-2-oxazoline) (PiPOx) and critical flocculation temperature (CFT) of the core-shell nanoparticle dispersion. Cores with diameters ranging from 5 to 21 nm were studied by temperature-cycled dynamic light scattering and differential scanning calorimetry over a large range of concentrations. We show that core size and curvature only have a minor influence on particle aggregation (CFT and cluster size), while they have major influence on the CST of the polymer shell. The densely grafted shells exhibit three distinct solvation transitions, the relative contributions of each is controlled by the core curvature. We link these transitions to different polymer density regimes within the spherical brush and demonstrate that the CST of the innermost part of the brush coincides with the CFT of the particle dispersion.
RESUMEN
PET was developed in the 1970s as an in vivo method to measure regional pathophysiologic processes. In the 1990s the focus moved to the detection of local increases in uptake, first in the brain (activation studies) and later in oncology (finding metastases), with 18F-FDG emerging as a highly sensitive staging technique. This focus on sensitivity has overshadowed the other main characteristic of PET, its quantitative nature. In recent years there has been a shift. PET is now seen as a promising tool for drug development and precision medicine-that is, a method to monitor or even predict response to therapy. Quantification is essential for precision medicine, but many studies today use simplified semiquantitative methods without properly validating them. This review provides several examples illustrating that simplified methods may lead to less accurate or even misleading results. Simplification is important for routine clinical practice, but finding the optimal balance between accuracy and simplicity requires careful studies. It is argued that the use of simplified approaches without proper validation not only may waste time and resources but also may raise ethical questions, especially in drug development studies.