Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Int J Exp Pathol ; 105(3): 90-99, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38717047

RESUMEN

Management of lung cancer today obligates a mutational analysis of the epidermal growth factor receptor (EGFR) gene particularly when Tyrosine Kinase Inhibitor (TKI) therapy is being considered as part of prognostic stratification. This study evaluates the performance of automated microfluidics-based EGFR mutation detection and its significance in clinical diagnostic settings. Formalin-fixed, paraffin-embedded (FFPE) samples from NSCLC patients (n = 174) were included in a two-phase study. Phase I: Validation of the platform by comparing the results with conventional real-time PCR and next-generation sequencing (NGS) platform. Phase II: EGFR mutation detection on microfluidics-based platform as part of routine diagnostics workup. The microfluidics-based platform demonstrates 96.5% and 89.2% concordance with conventional real-time PCR and NGS, respectively. The system efficiently detects mutations across the EGFR gene with 88.23% sensitivity and 100% specificity. Out of 144 samples analysed in phase II, the platform generated valid results in 94% with mutation detected in 41% of samples. This microfluidics-based platform can detect as low as 5% mutant allele fractions from the FFPE samples. Therefore the microfluidics-based platform is a rapid, complete walkaway, with minimum tissue requirement (two sections of 5 µ thickness) and technical skill requirement. The method can detect clinically actionable EGFR mutations efficiently and can be considered a reliable diagnostic platform in resource-limited settings. From receiving samples to reporting the results this platform provides accurate data without much manual intervention. The study helped to devise an algorithm that emphasizes effective screening of the NSCLC cases for EGFR mutations with varying tumour content. Thus it helps in triaging the cases judiciously before proceeding with multigene testing.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Receptores ErbB , Secuenciación de Nucleótidos de Alto Rendimiento , Neoplasias Pulmonares , Mutación , Humanos , Receptores ErbB/genética , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patología , Carcinoma de Pulmón de Células no Pequeñas/genética , Análisis Mutacional de ADN/métodos , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Microfluídica/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Técnicas Analíticas Microfluídicas/métodos , Adhesión en Parafina
2.
Anal Bioanal Chem ; 415(17): 3535-3547, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37254002

RESUMEN

Circulating tumor cells (CTCs) are cells shed from primary or metastatic tumors and spread into the peripheral bloodstream. Mutation detection in CTCs can reveal vital genetic information about the tumors and can be used for "liquid biopsy" to indicate cancer treatment and targeted medication. However, current methods to measure the mutations in CTCs are based on PCR or DNA sequencing which are cumbersome and time-consuming and require sophisticated equipment. These largely limited their applications especially in areas with poor healthcare infrastructure. Here we report a simple, convenient, and rapid method for mutation detection in CTCs, including an example of a deletion at exon 19 (Del19) of the epidermal growth factor receptor (EGFR). CTCs in the peripheral blood of NSCLC patients were first sorted by a double spiral microfluidic chip with high sorting efficiency and purity. The sorted cells were then lysed by proteinase K, and the E19del mutation was detected via real-time recombinase polymerase amplification (RPA). Combining the advantages of microfluidic sorting and real-time RPA, an accurate mutation determination was realized within 2 h without professional operation or complex data interpretation. The method detected as few as 3 cells and 1% target variants under a strongly interfering background, thus, indicating its great potential in the non-invasive diagnosis of E19del mutation for NSCLC patients. The method can be further extended by redesigning the primers and probes to detect other deletion mutations, insertion mutations, and fusion genes. It is expected to be a universal molecular diagnostic tool for real-time assessment of relevant mutations and precise adjustments in the care of oncology patients.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Células Neoplásicas Circulantes , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/genética , Microfluídica , Recombinasas/genética , Carcinoma de Pulmón de Células no Pequeñas/genética , Receptores ErbB/genética , Mutación , Células Neoplásicas Circulantes/patología
3.
Pathol Oncol Res ; 28: 1610607, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36277960

RESUMEN

EGFR mutation in non-small cell lung cancer (NSCLC) offers a potential therapeutic target for tyrosine kinase inhibitor (TKI) therapy. The majority of these cases, however eventually develop therapy resistance, mainly by acquiring EGFR T790M mutation. Recently, third-generation TKIs have been introduced to overcome T790M mutation-related resistance. Cell free circulating tumor DNA (liquid biopsy) has emerged as a valuable alternative method for T790M mutation detection during patient follow up, when a tissue biopsy cannot be obtained for analysis. In this study, we summarized our experience with Super-ARMS EGFR Mutation Detection Kit (AmoyDx) on 401 samples of 242 NSCLC patients in a 3-year period in Hungary, comprising 364 plasma and 37 non-plasma samples. We also compared the performance of two commercially available detection kits, the cobas EGFR Mutation test v2 (Roche) and the Super-ARMS EGFR Mutation Detection Kit (AmoyDx). The same activating EGFR mutation was detected with the AmoyDx kit as in the primary tumor in 45.6% of the samples. T790M mutation was identified in 48.1% of the samples containing activating EGFR mutation. The detection rate of T790M mutation was not dependent on the DNA concentration of the plasma sample and there was no considerable improvement in mutation detection rate after a second, subsequent plasma sample. The concordance of EGFR activating mutation detection was 89% between the two methods, while this was 93% for T790M mutation detection. The AmoyDx kit, however showed an overall higher detection rate of T790M mutation compared to the cobas kit (p = 0.014). T790M mutation was detected at 29.8% of the patients if only plasma samples were available for analysis, while the detection rate was 70.2% in non-plasma samples. If the activating EGFR was detected in the plasma samples, the detection rate of T790M mutation was 42.4%. Although non-plasma samples provided a superior T790M mutation detection rate, we found that liquid biopsy can offer a valuable tool for T790M mutation detection, when a tissue biopsy is not available. Alternatively, a liquid biopsy can be used as a screening test, when re-biopsy should be considered in case of wild-type results.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , ADN Tumoral Circulante , Neoplasias Pulmonares , Humanos , Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Carcinoma de Pulmón de Células no Pequeñas/genética , Carcinoma de Pulmón de Células no Pequeñas/patología , Receptores ErbB/genética , ADN Tumoral Circulante/genética , Neoplasias Pulmonares/tratamiento farmacológico , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patología , Mutación/genética , Inhibidores de Proteínas Quinasas/uso terapéutico , Resistencia a Antineoplásicos/genética
4.
Talanta ; 225: 122057, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-33592778

RESUMEN

Microfluidics has become a reliable platform for circulating tumor cells (CTCs) detection because of its high integration, small size, low consumption of reagents and rapid response. Here, we developed a multifunctional microfluidic device consists of three parts, including CTCs capture area, single-layer membrane valves area, and microcavity nucleic acid detection and analysis region based on digital polymerase chain reaction (dPCR), allowing CTCs capture, lysis, and genetic characterization to be performed on a single chip. The CTCs capture chip is coupled to the nucleic acid detection chip via a control valve. CTCs were firstly trapped in the CTC capture area, and then lysed using proteinase K to release nucleic acids. Subsequently CTCs lysate was transferred into nucleic acid detection area consisting of 12800 micro-cavity chambers for nucleic acids detection. To evaluate the performance of this chip, this study detected EGFR-L858R mutation in lung cancer cell lines H1975 and A549 cells, as well as leukocytes from normal donors. The results showed that positive signals were only observed in H1975 cells, and the detected value had a high linear relationship with the expected value (R2 = 0.9897). In conclusion, this multi-functional microfluidic chip that integrates CTCs capture, lysis and nucleic acid detection can successfully detect gene mutations in CTCs, providing reference for tumor-targeted drugs and precise diagnosis and treatment.


Asunto(s)
Técnicas Analíticas Microfluídicas , Células Neoplásicas Circulantes , Línea Celular Tumoral , Separación Celular , Receptores ErbB/genética , Humanos , Pulmón , Microfluídica , Mutación
5.
Thorac Cancer ; 10(10): 1973-1983, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31441578

RESUMEN

BACKGROUND: Both quantitative and qualitative aspects of plasma cell-free DNA (plasma cfDNA, pcfDNA) have been well-studied as potential biomarkers in non-small cell lung cancer (NSCLC). Accumulating evidence has proven that saliva also has the potential for the detection and analysis of circulating free DNA (saliva cfDNA, scfDNA). METHODS: In the current study, we aimed to explore the potential application of scfDNA in NSCLC diagnostics and consistency of epidermal growth factor receptor (EGFR) mutation detection in paired pcfDNA and scfDNA using droplet digital PCR (ddPCR) and analyze the relationship between EGFR mutations and clinical treatment response. RESULTS: In the quantitative cohort study, scfDNA concentration in NSCLC patients was no different from that in healthy donors, or in benign patients. ScfDNA concentration was significantly lower than pcfDNA concentration, yet they were not statistically significant in relevance (Spearman's rank correlation r = -0.123, P = 0.269). In the qualitative cohort study, the overall concordance rate of EGFR mutations between pcfDNA and scfDNA was 83.78% (31 of 37; k = 0.602; P < 0.001). EGFR mutation detection in paired pcfDNA and scfDNA was significantly correlated with the clinical treatment response (Spearman's rank correlation r = 0.664, P = 0.002). CONCLUSIONS: Our results demonstrated that saliva might not be the idea material for a cfDNA quantitative test, and scfDNA concentration is not applicable for NSCLC diagnostics. Conversely, scfDNA was capable of acting as the supplement for EGFR mutations due to the coincidence rate of EGFR mutation detection between scfDNA and pcfDNA.


Asunto(s)
Biomarcadores de Tumor , Carcinoma de Pulmón de Células no Pequeñas/genética , Ácidos Nucleicos Libres de Células , Neoplasias Pulmonares/genética , Mutación , Saliva/metabolismo , Adulto , Anciano , Receptores ErbB/genética , Exones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Sensibilidad y Especificidad , Eliminación de Secuencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA