Resultados 1 - 20 de 55
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Anal Bioanal Chem ; 416(21): 4759-4767, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38647693

RESUMEN

A highly efficient ratiometric electrochemiluminescence (ECL) immunoassay was explored by bidirectionally regulating the ECL intensity of two luminophors. The immunoassay was conducted in a split-type mode consisting of an ECL detection procedure and a sandwich immunoreaction. The ECL detection was executed using a dual-disk glassy carbon electrode modified with two potential-resolved luminophors (g-C3N4-Ag and Ru-MOF-Ag nanocomposites), and the sandwich immunoreaction using glucose oxidase (GOx)-modified SiO2 nanospheres as labels was carried out in a 96-well plate. The Ag nanoparticles (NPs) acted as bifunctional units both for triggering the resonance energy transfer (RET) with g-C3N4 and for accelerating the electron transfer rate of the Ru-MOF-Ag ECL reaction. When the H2O2 catalyzed by GOx in the 96-well plate was transferred to the dual-disk glass carbon electrode, the doped Ag NPs in the two luminophors could be etched, thus destroying the RET between C3N4 and the accelerated reaction to Ru-MOF, resulting in an opposite trend in the ECL signal outputted from the dual disks. Using the ratio of the two signals for quantification, the constructed immunosensor for a model target, i.e. myoglobin, exhibited a low detection limit of 4.7 × 10-14 g/mL. The ingenious combination of ECL ratiometry, bifunctional Ag NPs, and a split-type strategy effectively reduces environmental and human errors, offering a more precise and sensitive analysis for complex samples.


Asunto(s)
Técnicas Electroquímicas , Glucosa Oxidasa , Límite de Detección , Mediciones Luminiscentes , Nanopartículas del Metal , Plata , Plata/química , Inmunoensayo/métodos , Nanopartículas del Metal/química , Técnicas Electroquímicas/métodos , Mediciones Luminiscentes/métodos , Glucosa Oxidasa/química , Glucosa Oxidasa/metabolismo , Técnicas Biosensibles/métodos , Mioglobina/análisis , Dióxido de Silicio/química
2.
BMC Geriatr ; 23(1): 274, 2023 05 05.
Artículo en Inglés | MEDLINE | ID: mdl-37147588

RESUMEN

BACKGROUND: In the 19th century, neurosyphilis was the most frequent cause of dementia in Western Europe. Now dementia caused by syphilis has become rare in Germany. We studied whether routine testing of patients with cognitive abnormalities or neuropathy for antibodies against Treponema pallidum has therapeutic consequences in geriatric patients. METHODS: A Treponema pallidum electrochemiluminescence immunoassay (TP-ECLIA) is routinely performed in all in-patients treated at our institution with cognitve decline or neuropathy and no or insufficient previous diagnostic workup. Patients with a positive TP-ECLIA treated from October 2015 to January 2022 (76 months) were retrospectively evaluated. In cases of positive TP-ECLIA, further specific laboratory investigations were performed to assess whether antibiotic therapy was indicated. RESULTS: In 42 of 4116 patients (1.0%), TP-ECLIA detected antibodies directed against Treponema in serum. Specifity of these antibodies was ensured by immunoblot in 22 patients (11 × positiv, 11 × borderline values). Treponema-specific IgM was detectable in the serum of one patient, in 3 patients the Rapid Plasma Reagin (RPR) test, a modified Venereal Disease Research Laboratory test (VDRL), in serum was positiv. CSF analysis was performed in 10 patients. One patient had CSF pleocytosis. In 2 other patients, the Treponema-specific IgG antibody index was elevated. 5 patients received antibiotic therapy (4 × ceftriaxone 2 g/d i.v., 1 × doxycycline 300 mg/d p.o.). CONCLUSION: In approx. 1‰ of patients with previously undiagnosed or not sufficiently diagnosed cognitive decline or neuropathy, the diagnostic workup for active syphilis resulted in a course of antibiotic treatment.


Asunto(s)
Disfunción Cognitiva , Demencia , Polineuropatías , Sífilis , Humanos , Anciano , Sífilis/complicaciones , Sífilis/diagnóstico , Sífilis/tratamiento farmacológico , Diagnóstico Diferencial , Estudios Retrospectivos , Treponema pallidum , Polineuropatías/diagnóstico , Antibacterianos , Disfunción Cognitiva/diagnóstico , Demencia/diagnóstico
3.
Biomed Chromatogr ; 37(2): e5538, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36271903

RESUMEN

Tacrolimus (TAC) and sirolimus (SIR) antirejection medications are widely used in organ transplantation. We aimed to develop an ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) assay for quantifying TAC and SIR simultaneously and evaluating agreement with chemiluminescence microparticle immunoassay (CMIA) and electrochemiluminescence immunoassay (ECLIA). Whole blood samples collected from 209 TAC and 208 SIR patients were assessed by UHPLC-MS/MS, CMIA and ECLIA. The agreement of the three techniques was assessed using the Bland-Altman plot. The UHPLC-MS/MS assay had a calibration range of 1-100 ng/ml for TAC and SIR. The accuracy and precision were -2.73-4.32% and <4.71% for TAC, respectively, and 0.07-4.84% and <6.5% for SIR, respectively. The three methods had good correlation. In comparison with UHPLC-MS/MS, two immunoassays showed a slight deviation in proportion. An UHPLC-MS/MS method for simultaneously detecting TAC and SIR in human whole blood was developed, validated and comparatively analyzed with CMIA and ECLIA. For determining TAC and SIR, immunoassays displayed acceptable analytical performances in terms of precision and correlation compared with UHPLC-MS/MS. However, further investigation is warranted to examine the novel method.


Asunto(s)
Sirolimus , Tacrolimus , Humanos , Cromatografía Líquida de Alta Presión/métodos , Inmunosupresores , Espectrometría de Masas en Tándem/métodos , Monitoreo de Drogas/métodos , Inmunoensayo/métodos
4.
Indian J Clin Biochem ; 38(1): 51-58, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35465605

RESUMEN

The vaccination efficacy can indirectly be assessed through the quantification of neutralizing antibodies. Very few data are available on Covishield efficacy in terms of neutralizing antibody expression upon vaccination. This study is focused on profiling of neutralizing antibody expression during and after the Covishield two shot vaccination and observing COVID-19 infection in vaccinated participants during the period. SARS CoV-2 neutralizing antibody concentrations in samples were estimated using electrochemiluminescence immunoassay kit for Lifotronics eCL8000. The sampling had been done sequentially at 45th, 85th day after 1st dose and 15th day after 2nd dose Covishield vaccination. Parallelly, in order to confirm the total SARS CoV-2 IgG response in COVID-19 infection, measured the IgG using SARS CoV-2 IgG lateral flow immunoassay test kit. The subjects previously infected with COVID-19 before 1st dose vaccination demonstrated high neutralizing antibody (> 10AU/ml). In COVID-19 uninfected subjects, there was a sudden incline in neutralizing antibody after the 2nd dose. Infection with SARS CoV-2 between 1st and 2nd dose of Covishield vaccination implicate that the level of neutralizing antibody in serum after 1st dose was not adequate to combat the virus and prevent infection. We observed COVID-19 infection in participants even after 2nd dose of vaccination. Interestingly, there was no protection against SARS CoV-2 even with a high neutralizing antibody expression of 188.5 AU/mL after the 2nd dose. Findings of Covishield efficacy in different cohort samples before and after 2 doses of Covishield vaccination provide impetus for improvement or development of next generation vaccines.

5.
Anal Biochem ; 656: 114876, 2022 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-36058293

RESUMEN

Paired box protein Pax-6 (oculothrombin) is a transcription factor that plays an important regulatory role in ocular, brain, and pancreatic development. Mutations of the PAX6 gene cause aniridia and Peters anomaly. Reduction in Pax-6 protein is also associated with ocular diseases such as dry eye. An electrochemiluminescence immunoassay method using the Meso Scale Discovery platform was developed to measure Pax-6 protein levels in corneal epithelial cells obtained by impression cytology. Impression cytology involves harvesting ocular epithelial cells by applying a polyethersulfone membrane patch briefly to the ocular surface using a commercially available EYEPRIM™ device. The epithelial cells that adhere to the membrane patch of the EYEPRIM™ device provide a biological sample which can be assayed for Pax-6 protein levels. Assay development identified an antibody pair capable of detecting purified recombinant Pax-6 protein produced in mammalian cells. The optimized assay has a dynamic range of 24 pg mL-1 to 100,000 pg mL-1 and a lower limit of quantification of 24 pg mL-1. Assay selectivity was demonstrated using either HeLa or HEK293 cells transfected with inhibitory RNA. Finally, the method was validated by measuring Pax-6 protein levels in impression cytology acquired samples obtained using the EYEPRIM™ device from rabbit cornea.


Asunto(s)
Proteínas de Homeodominio , Factores de Transcripción Paired Box , Animales , Proteínas del Ojo/genética , Células HEK293 , Proteínas de Homeodominio/genética , Humanos , Inmunoensayo , Mamíferos/genética , Mamíferos/metabolismo , Factor de Transcripción PAX6 , Factores de Transcripción Paired Box/genética , ARN , Conejos , Proteínas Represoras/genética
6.
Brain Inj ; 36(6): 792-799, 2022 05 12.
Artículo en Inglés | MEDLINE | ID: mdl-35253561

RESUMEN

BACKGROUND: Previous studies have indicated the utility of the ADAM10-generated fragment of tau, Tau-A, as marker of neuronal damage. However, the sensitivity of the ELISA-based system was limited. OBJECTIVES: We utilized the extensive dynamic range of electrochemiluminescence compared to colorimetric assessment to improve the sensitivity of the Tau-A assay and investigate Tau-A levels after brain injury. METHODS: We converted the Tau-A competitive ELISA to a competitive electrochemiluminescence-based immunoassay, Tau-A ECLIA, and compared the methods by measuring serum samples in a TBI (n = 40) and a stroke cohort (n = 64). RESULTS: The Tau-A ECLIA was technically robust. Only 1% of the samples was below the detection limit in the ECLIA compared to 10.6% in the ELISA . Tau-A measured in both assays could discriminate between patients with a TBI and non-trauma controls (ELISA: p = 0.0005, ECLIA: p = 0.0002). The increased dynamic range of the Tau-A ECLIA also allowed discrimination between healthy controls from patients with hemorrhagic (p = 0.0172) and severe ischemic stroke (p = 0.0118) respectively, as well as patients with mild ischemic stroke from severe (p = 0.0445). CONCLUSIONS: The Tau-A ECLIA was characterized by dynamic range compared to the ELISA, which facilitated a better separation between the patient groups. Tau-A warrants further investigation as a neuronal injury associated marker.


Asunto(s)
Lesiones Encefálicas , Accidente Cerebrovascular Isquémico , Biomarcadores , Ensayo de Inmunoadsorción Enzimática , Humanos
7.
Arch Gynecol Obstet ; 303(1): 129-134, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32815025

RESUMEN

BACKGROUND: Elevated concentrations of circulating testosterone are present in hyperreactio luteinalis (HL), a pregnancy-specific, self-limited condition. HL is associated with maternal virilization in about 30% of cases. The correlation between testosterone levels and maternal virilization has not yet been quantified. Our aim was to identify a testosterone cut-off level which may allow to predict maternal virilization. METHODS: A literature research was performed. Publications were chosen if serum testosterone concentrations and presence or absence of maternal virilization was mentioned. Additionally, we report serial levels of steroids analyzed by Liquid chromatography-tandem mass spectrometry (LC-MS/MS) in one case of HL managed at our institution. RESULTS: In all, 31 cases fulfilled the search criteria. We found significant overlap between testosterone levels in asymptomatic women and women with signs of virilization (range 6.2-37.3 nmol/l and 13.7-197.5 nmol/l, respectively). The method applied for testosterone analysis was mentioned in three reports only. Peak serum testosterone concentration in our case was 120.3 nmol/l. CONCLUSION: From the available data, maternal virilization in HL cannot be predicted by the level of circulating testosterone. However, comparability of results is hampered by the analytical methods applied. LC-MS/MS should preferably be used for reporting concentrations of circulating testosterone.


Asunto(s)
Complicaciones del Embarazo/diagnóstico , Testosterona/sangre , Virilismo/sangre , Adulto , Cromatografía Liquida , Femenino , Humanos , Quistes Ováricos , Embarazo , Espectrometría de Masas en Tándem
8.
Reprod Biomed Online ; 41(1): 29-36, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32466992

RESUMEN

RESEARCH QUESTION: What is the performance of anti-Müllerian hormone (AMH) as measured by the Elecsys® AMH assay in predicting ovarian response in women treated with 150 µg corifollitropin alfa (CFA)? DESIGN: Multicentre, prospective study conducted between December 2015 and April 2018. Women were aged 18-43 years, had regular menstrual bleeding, a body mass index of 17-35 kg/m2 and weighed 60 kg or over. EXCLUSION CRITERIA: previous oophorectomy, history of ovarian hyperstimulation syndrome, a previous IVF and intracytoplasmic sperm injection cycle producing over 30 follicles measuring 11 mm or wider, basal antral follicle count (AFC) over 20 or polycystic ovarian syndrome. All women were treated with 150 µg CFA followed by recombinant FSH (150-300 IU/day) in a fixed gonadotrophin releasing hormone antagonist protocol. RESULTS: Of the 219 patients enrolled, 22.8% had low ovarian response (three or fewer oocytes), 66.2% had normal response and 11% had high ovarian response (15 or more oocytes). The AMH and AFC presented an area under the curve of 0.883 (95% CI 0.830 to 0.936) and 0.879 (95% CI 0.826 to 0.930), respectively, for low ovarian response; and an AUC of 0.865 (95% CI 0.793 to 0.935) and 0.822 (95% CI 0.734 to 0.909) for high ovarian response. An AMH cut-off of 1.0 ng/ml provided a sensitivity of 92.0% and a specificity of 66.9% in the prediction of low ovarian response; a cut-off of 2.25 ng/ml predicted high ovarian response with a sensitivity of 54.2% and a specificity of 91.8%. CONCLUSIONS: The automated Elecsys® AMH assay predicts ovarian response in a CFA antagonist protocol. The best predictors of ovarian response in CFA-treated patients were AMH and AFC.


Asunto(s)
Hormona Antimülleriana/sangre , Hormona Folículo Estimulante Humana/administración & dosificación , Inmunoensayo/métodos , Ovario/efectos de los fármacos , Inducción de la Ovulación/métodos , Adolescente , Adulto , Biomarcadores/sangre , Femenino , Fertilización In Vitro/métodos , Humanos , Estudios Prospectivos , Inyecciones de Esperma Intracitoplasmáticas/métodos , Resultado del Tratamiento , Adulto Joven
9.
Endocr J ; 67(7): 759-770, 2020 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-32269183

RESUMEN

Calcitonin (CT) is a marker for both initial diagnosis and monitoring of patients with residual or recurrent medullary thyroid carcinoma (MTC). In Japan, serum CT had been measured by radioimmunoassay (RIA) until recently. Electrochemiluminescence immunoassay (ECLIA) became commercially available in 2014, and this technique is now the only method used to examine CT concentration. The purposes of this study were to investigate the correlations between the CT concentration measured with ECLIA (ECLIA-CT) and RIA (RIA-CT) and to explore the clinical characteristics of patients with elevated ECLIA-CT. CT concentrations of 348 sera samples from 334 patients with various thyroid disorders including nine MTC were measured using both assays. The correlation analysis revealed an excellent correlation between ECLIA-CT and RIA-CT among the cases with CT level >150 pg/mL by both assays (rs = 0.991, p < 0.001). However, 63% of all samples exhibited undetectable ECLIA-CT, while their RIA-CTs were measured between 15 and 152 pg/mL. The ECLIA-CTs in all patients who underwent total thyroidectomy for non-MTC showed low concentrations. High ECLIA-CT was observed in patients with MTC or pancreas neuroendocrine tumor. ECLIA-CT was also increased in 14 other male patients with non-MTC, including four with renal failure. Multivariate logistic regression analysis showed that male sex, negative TgAb, and lower estimated glomerular filtration rate were independent factors to predict detectable ECLIA-CT (≥0.500 pg/mL). These results indicate that ECLIA-CT correlates well with RIA-CT in higher range and is affected by sex, TgAb, and renal function.


Asunto(s)
Autoanticuerpos/sangre , Calcitonina/análisis , Carcinoma Neuroendocrino/diagnóstico , Enfermedades Renales/sangre , Mediciones Luminiscentes/métodos , Neoplasias de la Tiroides/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Autoanticuerpos/inmunología , Biomarcadores de Tumor/análisis , Biomarcadores de Tumor/sangre , Calcitonina/sangre , Calcitonina/normas , Carcinoma Neuroendocrino/sangre , Carcinoma Neuroendocrino/complicaciones , Carcinoma Neuroendocrino/fisiopatología , Niño , Estudios de Cohortes , Femenino , Humanos , Inmunoensayo/métodos , Inmunoensayo/normas , Enfermedades Renales/complicaciones , Enfermedades Renales/fisiopatología , Pruebas de Función Renal/normas , Mediciones Luminiscentes/normas , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Radioinmunoensayo/métodos , Radioinmunoensayo/normas , Valores de Referencia , Factores Sexuales , Neoplasias de la Tiroides/sangre , Neoplasias de la Tiroides/complicaciones , Neoplasias de la Tiroides/fisiopatología , Adulto Joven
10.
Clin Chem Lab Med ; 57(8): 1242-1250, 2019 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-30794525

RESUMEN

BACKGROUND: There is only limited information on serum reference ranges of calcitonin (CT) in infants, children and adolescents. This gap hampers valid diagnostics in patients with multiple endocrine neoplasia type 2 (MEN 2) and planned prophylactic thyroidectomy. In addition, age-dependent reference ranges for CT are necessary to define a cure in medullary thyroid carcinoma (MTC). We asked whether the reference ranges for CT levels were age- and gender-dependent in the serum of a pediatric cohort. METHODS: A total of 6090 serum samples of 2639 subjects of the LIFE-Child cohort aged between 1 month and 17.9 years were analyzed by the CT electrochemiluminescence immunoassay (ECLIA). Reference intervals were estimated using the LMS method. For clinical validation the serum of 28 patients (61 samples) with MEN 2 and 106 patients (136 samples) with thyroid diseases were analyzed. RESULTS: CT levels showed a clear age- and gender-dependence with significantly higher values in boys (p<0.01). An accelerated decline of CT levels from newborn to children at the age of 4 and 5 years was observed for both sexes. A cure for MTC was demonstrated in 71% of MEN 2 patients after thyroidectomy, whereas 5 patients remained suspicious for micrometastasis or relapse. Only 1.5% of our patients with thyroid diseases revealed increased CT levels. CONCLUSIONS: This is the largest study to establish novel pediatric reference ranges from the CT values of healthy subjects. It allows a precise laboratory monitoring of CT in pediatric patients with MEN 2. Thyroid diseases did not have a relevant influence on CT levels in our pediatric cohort.


Asunto(s)
Análisis Químico de la Sangre , Calcitonina/sangre , Carcinoma Neuroendocrino/sangre , Enfermedades de la Tiroides/sangre , Neoplasias de la Tiroides/sangre , Adolescente , Biomarcadores/sangre , Calcitonina/normas , Niño , Preescolar , Estudios de Cohortes , Femenino , Humanos , Lactante , Masculino , Valores de Referencia , Factores Sexuales
11.
J Clin Microbiol ; 56(5)2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29444836

RESUMEN

Serology is the preferred method to confirm a Chagas disease diagnosis and to screen blood donors. A battery of assays is often required due to the limited accuracy of single assays. The Elecsys Chagas assay is a newly developed, double-antigen sandwich assay for use on the Elecsys and cobas e immunoassay analyzers, intended to identify individuals infected with Trypanosoma cruzi, for diagnosis and screening. The performance of the Elecsys Chagas assay was evaluated in comparison with those of other widely used T. cruzi antibody assays, at multiple sites (Europe/Latin America). Relative sensitivity and specificity were assessed by using samples from blood donors, pregnant women, and hospitalized patients from regions where Chagas disease is endemic and from regions of nonendemicity. The Elecsys Chagas assay had an overall relative sensitivity of 100% (n = 674). Overall relative specificities were 99.90% (n = 14,681), 100% (n = 313), and 100% (n = 517) for samples from blood donors, pregnant women, and hospitalized patients, respectively. The analytical specificity was 99.83% (n = 594). The Elecsys Chagas assay detected T. cruzi antibodies in two World Health Organization (WHO) standard T. cruzi reference panels (panels 09/188 and 09/186) at a 1:512 dilution, corresponding to a cutoff sensitivity of approximately 1 mIU/ml. The Elecsys Chagas assay demonstrated robust performance under routine conditions at multiple sites in Europe and Latin America. In contrast to other available Chagas assays, the Elecsys assay uses a reduced number of recombinant T. cruzi antigens, resulting in a significantly smaller number of cross-reactions and improved analytical specificity while being highly sensitive.


Asunto(s)
Anticuerpos Antiprotozoarios/sangre , Enfermedad de Chagas/diagnóstico , Inmunoensayo/métodos , Pruebas Serológicas/métodos , Trypanosoma cruzi/inmunología , Europa (Continente) , Femenino , Humanos , América Latina , Masculino , Embarazo , Sensibilidad y Especificidad
12.
Clin Chem Lab Med ; 56(5): 838-842, 2018 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-29194037

RESUMEN

BACKGROUND: Reference intervals (RIs) play key roles in clinical diagnosis, treatment and prognosis. However, RIs for clinical testing tend to be confined to the general population, and RIs for pregnant women are not very comprehensive. In this study, we establish RIs for prolactin (PRL) in healthy pregnant and postpartum women in the Chinese population. METHODS: Healthy pregnant women (n=378) were divided into groups according to whether they were in the first, second or third trimester of pregnancy. Healthy postpartum women (n=493) were separated into four groups according to mode of delivery as follows: postvaginal (24 and 48 h) or postcesarean (24 and 48 h). Healthy, non-pregnant women (n=123) were enrolled as a control group. Serum PRL levels were measured by electrochemiluminescence immunoassay, and RIs were established for each group. RESULTS: The RIs for PRL were as follows: healthy non-pregnant women, 178.89-757.52 µIU/mL; first trimester, 621.20-3584.00 µIU/mL; second trimester, 1432.00-5349.68 µIU/mL; third trimester, 4087.33-9733.65 µIU/mL; 24 and 48 h postvaginal delivery (combined), 7865.36-10998.86 µIU/mL; and 24 and 48 h postcesarean delivery, 4556.41-7675.99 and 6578.45-9980.45 µIU/mL, respectively. CONCLUSIONS: PRL RIs for pregnant women were established according to trimester, days postpartum and mode of delivery, thus providing a clinical reference for medical staff.


Asunto(s)
Prolactina/sangre , Adulto , China , Técnicas Electroquímicas/normas , Femenino , Humanos , Inmunoensayo/normas , Mediciones Luminiscentes/normas , Embarazo , Prolactina/normas , Valores de Referencia
13.
J Infect Chemother ; 24(11): 887-891, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30197093

RESUMEN

The accuracy of the test is critical for the syphilis serology diagnosis. This study aims to evaluate the values of the Elecsys syphilis assay, the Architect syphilis assay, and the Mindray syphilis assay, as syphilis screening tests for pregnant women and patients with syphilis or other diseases. A reverse algorithm was used for the syphilis serology diagnosis. Serum samples (n = 584) were tested with three automated screening assays. All reactive sera by one, two, or three screening assays were further analyzed with the tolulized red unheated serum test (TRUST). Inconsistent results were confirmed by the Treponema pallidum particle agglutination assay (TPPA). The final patient diagnosis was made according to the results of syphilis serology, clinical evidence, and past medical history. The sensitivity, specificity, accuracy, and kappa value of each assay were as follows: for the Elecsys syphilis assay, 100.0%, 98.5%, 98.6%, and 0.927, respectively; for the Architect syphilis assay: 100.0%, 94.5%, 95.0%, and 0.770; and for the Mindray syphilis assay: 100.0%, 97.0%, 97.3%, and 0.862. The McNemar test showed that there were significant differences in the performance between the Elecsys syphilis assay and the Architect syphilis assay (P < 0.001), and between the Mindray syphilis assay and the Architect syphilis assay (P = 0.001). Our study demonstrated that three automated Treponema pallidum antibody assays generally showed high sensitivities and specificities, and so, they are suitable for use in screening for syphilis. The performances of the Elecsys syphilis assay and the Mindray syphilis assay are superior to Architect syphilis assay.


Asunto(s)
Anticuerpos Antibacterianos/aislamiento & purificación , Complicaciones Infecciosas del Embarazo/diagnóstico , Serodiagnóstico de la Sífilis/métodos , Sífilis/diagnóstico , Treponema pallidum/inmunología , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Anticuerpos Antibacterianos/inmunología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Embarazo , Complicaciones Infecciosas del Embarazo/sangre , Complicaciones Infecciosas del Embarazo/inmunología , Complicaciones Infecciosas del Embarazo/microbiología , Estudios Prospectivos , Sensibilidad y Especificidad , Sífilis/sangre , Sífilis/inmunología , Sífilis/microbiología , Treponema pallidum/aislamiento & purificación , Adulto Joven
14.
J Clin Pharm Ther ; 43(5): 675-681, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29679392

RESUMEN

WHAT IS KNOWN AND OBJECTIVE: For analysis of blood concentrations of everolimus, many hospital laboratories use either latex agglutination turbidimetric immunoassay (LTIA) or electrochemiluminescence immunoassay (ECLIA). However, no studies have compared both immunoassay methods under the same conditions. Accordingly, in this study, we compared everolimus blood concentrations obtained by LTIA and ECLIA in renal transplant patients. METHODS: Blood samples (n = 230) from 60 renal transplant patients (19 female and 41 male) were evaluated using both immunoassays. Subsequently, we switched the assay for detection of everolimus blood concentrations from LTIA to ECLIA as a clinical application. Three quality control (QC) samples for LTIA were analysed using ECLIA, and 3 QC samples for ECLIA were analysed using LTIA. RESULTS: The Deming regression of ECLIA versus LTIA generated the following parameters: slope, 1.0067 and intercept, 1.7489 ng/mL, in the analysis of 230 samples. Bland-Altman analysis showed an average positive bias of 1.73 ng/mL between ECLIA and LTIA. When the clinical apparatus was switched from LTIA to ECLIA, the average everolimus blood concentration assayed by LTIA before switching was 3.57 ng/mL, whereas that by ECLIA after switching in the same patients taking the same daily dose (mean: 1.43 mg/day) was 5.85 ng/mL. The QCs assayed using LTIA were lower by an average of 67.3% (range: 55.8%-79.5%) for ECLIA, and in the same 230 samples from patients, the everolimus blood concentrations assayed by LTIA were lower by an average of 67.4% (range: 37.1%-114.5%) of ECLIA. WHAT IS NEW AND CONCLUSION: Analysis of everolimus concentrations by immunoassays with high precision and accuracy is required to ensure long-term survival of transplant recipients. Although the concentrations of QCs and calibrators of everolimus in LTIA were previously corrected to 70% concentration because of cross-reactivity with everolimus metabolites, these adjustments may need to be reviewed.


Asunto(s)
Aglutinación/efectos de los fármacos , Everolimus/sangre , Inmunoensayo/métodos , Inmunosupresores/sangre , Inmunoturbidimetría/métodos , Látex/inmunología , Pruebas Diagnósticas de Rutina/métodos , Monitoreo de Drogas/métodos , Femenino , Humanos , Trasplante de Riñón/métodos , Masculino , Persona de Mediana Edad
15.
Surg Today ; 48(2): 223-228, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28821980

RESUMEN

PURPOSE: Calcitonin is the most sensitive tumor marker of medullary thyroid carcinoma (MTC) and a calcium stimulation test is used to improve this sensitivity. In Japan, the electrochemiluminescence immunoassay (ECLIA) is currently the only test performed to measure serum calcitonin. There is a gender difference in the reference value of serum calcitonin; however, a reference upper limit for use with ECLIA has been reported only for women, but not for men. METHODS: We conducted the calcium stimulation test using ECLIA in 21 men with non-medullary thyroid carcinoma (non-MTC), before and after total thyroidectomy. RESULTS: Preoperatively, the basal calcitonin values were within normal limits in all patients. They increased to a mean value of 37.6 pg/mL after calcium stimulation, and we calculated that the reference upper limit was 83.7 pg/mL. The stimulation test results after total thyroidectomy showed undetectable basal and stimulated calcitonin values in every patient (<0.5 pg/mL). CONCLUSIONS: To our knowledge, this is the first study to calculate reference values for this stimulation test using an ECLIA in men with non-MTC. We propose that men can be regarded as biochemically cured or as having normal serum calcitonin values when the stimulated calcitonin values obtained by ECLIA are <83.7 pg/mL before and <0.5 pg/mL after total thyroidectomy.


Asunto(s)
Biomarcadores de Tumor/sangre , Calcitonina/sangre , Calcio , Técnicas Electroquímicas/métodos , Inmunoensayo/métodos , Mediciones Luminiscentes/métodos , Pruebas de Función de la Tiroides/métodos , Neoplasias de la Tiroides/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Pueblo Asiatico , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Sensibilidad y Especificidad , Neoplasias de la Tiroides/cirugía , Tiroidectomía
16.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 49(6): 924-928, 2018 Nov.
Artículo en Zh | MEDLINE | ID: mdl-32677406

RESUMEN

OBJECTIVE: To explore the interference of exogenous insulin therapy on insulin detection test by electrochemical luminescence immunoassay (ECLIA). METHODS: Insulin level was determined by ECLIA. According to the requirements of EP7-A2 of American Society for Clinical Laboratory Standards Institute Standards, paired difference experiment was conducted to evaluate the interference of 8 kinds of exogenous insulin on insulin detection, dose effect experiment was conducted to determine the relationship between exogenous insulin concentration and interference degree. RESULTS: When the interfering substance concentrations were ≤250 µU/mL, Gansulin NⓇ, Gansulin RⓇ, Humulin RⓇ,Novolin RⓇ and LantusⓇ all showed linear positive interference, while LevemirⓇ showed a linear negative interference in high concentrations insulin and non-interfering in low concentrations insulin, HumalogⓇ and Novo RapidⓇ showed non-interference in insulin detection. CONCLUSIONS: The use of different exogenous insulin may have different interference on insulin measurement, which need laboratorians and physicians notice to avoid misdiagnosis.

18.
Pediatr Int ; 57(2): 263-8, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25223367

RESUMEN

BACKGROUND: Serum procalcitonin (PCT) increases in various respiratory disorders such as acute respiratory distress syndrome. Elevated PCT is also observed in healthy neonates. In this study, we investigated whether PCT is a good marker of respiratory disorder in neonates. METHODS: A total of 155 neonates with or without respiratory disorder, were eligible for the study. PCT was measured on electrochemiluminescence immunoassay. Each neonate was allocated to the non-respiratory disorder (control) group (n = 95), or a respiratory disorder group (n = 60). PCT was compared between the groups, and association with other markers, including C-reactive protein (CRP) and white blood cell (WBC) count, was analyzed. RESULTS: Of the 60 neonates in the respiratory disorder group, 39, 10, five, one, two, two, and one neonates had transient tachypnea of the newborn, respiratory distress syndrome, air leak syndrome, meconium aspiration syndrome, 18-trisomy, neonatal asphyxia, and congenital diaphragmatic hernia, respectively. Mean PCT, CRP and WBC count in the respiratory disorder group were 9.01 ng/mL, 0.26 mg/dL, and 16,100 cells/µL, respectively. The area under the curve obtained for PCT in distinguishing between the respiratory disorder and control groups was 0.85 (sensitivity, 66.7%; specificity, 93.0%; optimum cut-off, 3.73 ng/mL), that for CRP was 0.72 (sensitivity, 75.0%; specificity, 64.6%; optimum cut-off, 0.14 mg/dL), and for WBC it was 0.44 (sensitivity, 60.0%; specificity, 29.6%; optimum cut-off, 15,000 cells/µL). CONCLUSIONS: PCT is more susceptible, as a diagnostic parameter of infection, to the effect of respiratory disturbance than CRP and WBC.


Asunto(s)
Biomarcadores/sangre , Calcitonina/sangre , Trastornos Respiratorios/diagnóstico , Proteína C-Reactiva/metabolismo , Femenino , Humanos , Recién Nacido , Recuento de Leucocitos , Mediciones Luminiscentes , Masculino , Curva ROC , Sensibilidad y Especificidad
19.
Mod Rheumatol ; 24(4): 580-4, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24252038

RESUMEN

OBJECTIVE: The automatic anti-cyclic citrullinated peptide (anti-CCP) antibodies assay offered great advantages over traditional methods in terms of improved precision, reliability, technical simplicity, short turnaround time and high-speed throughput. In this study, we evaluated the main technical performance and diagnostic accuracy of the first automatic anti-CCP assay approved in China. METHODS: The study comprised 106 rheumatoid arthritis (RA) patients, 203 non-RA rheumatic disease controls and 46 healthy persons. Anti-CCP, rheumatoid factor (RF), α1-acid glycoprotein, C-reactive protein and erythrocyte sedimentation rate were measured and compared. The precision, reference intervals for Chinese population and cut-off value for RA diagnosis, as well as the suitable diluent for anti-CCP were assessed. The positive rate and score of anti-CCP were compared with RF and acute-phase reactants, according to the new RA criteria. RESULTS: Within- and between-run imprecision, expressed as the coefficient of variation, were 0.47-1.36% and 1.15-2.63%, respectively. Upper 95% reference limit of anti-CCP in healthy Chinese was 8.8 U/mL. The area under curve of the receiver operating characteristic(ROC) for anti-CCP and RF were 0.882 (95% CI 0.833-0.930) and 0.844 (95% CI 0.792-0.897), respectively. Based on the cut-off value set by ROC, compared to RF, anti-CCP had higher sensitivity (96.8% vs. 78.3%) and specificity (90.9% vs. 70.7%). With 17 U/mL set as the optimal cut-off for anti-CCP, the total positivity of anti-CCP was comparable to that of RF (76.4% vs. 75.5%), but the high-positivity rate of anti-CCP was significantly higher (74.5% vs. 62.3%, p < 0.005). CONCLUSIONS: Our results confirm anti-CCP as a more sensitive and specific marker than RF for the diagnosis of RA. The diagnostic performance of the Elecsys anti-CCP assay makes it a useful adjunct to clinical practice in the Chinese population.


Asunto(s)
Artritis Reumatoide/diagnóstico , Autoanticuerpos/sangre , Péptidos Cíclicos/inmunología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Artritis Reumatoide/sangre , Artritis Reumatoide/inmunología , Proteína C-Reactiva/metabolismo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factor Reumatoide/sangre , Sensibilidad y Especificidad , Adulto Joven
20.
Talanta ; 276: 126205, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38718649

RESUMEN

Considering the high probability of recurrence or metastasis after thyroidectomy, it is meaningful to develop a rapid, sensitive and specific method for monitoring thyrophyma-related biomarkers. In this study, a homogeneous electrochemiluminescence immunoassay (HO-ECLIA) coupled with magnetic beads (MBs)-based enrichment tactic was established for the determination of thyrophyma-related thyroglobulin (Tg). Importantly, owing to the abundant surface groups and good biocompatibility of carbon quantum dots (CQDs), the incorporation of CQDs onto the Tg antigen surface was achieved, resulting in the formation of Tg-encapsulated CQDs (CQDs-Tg), which served not only as an ECL probe but as a biorecognition element. Under optimal experimental conditions, the proposed platform demonstrated a wide linear range from 0.01 to 100 ng·mL-1 with a detection limit of 6.9 pg·mL-1 (S/N = 3), and performed well in real serum sample analysis against interference. Collectively, the proposed platform exhibited the rapid response, satisfactory sensitivity and specificity toward Tg in complex serum milieu, and held a considerable potential for clinical prognosis monitoring of thyrophyma.


Asunto(s)
Técnicas Electroquímicas , Inmunoensayo , Tiroglobulina , Humanos , Carbono/química , Técnicas Electroquímicas/métodos , Inmunoensayo/métodos , Límite de Detección , Mediciones Luminiscentes/métodos , Puntos Cuánticos/química , Tiroglobulina/sangre
SELECCIÓN DE REFERENCIAS