J Am Soc Echocardiogr ; 34(7): 757-766.e8, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33675941

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) response assessment relies on the QRS complex narrowing criterion. Yet one third of patients do not improve despite narrowed QRS after implantation. Electromechanical wave imaging (EWI) is a quantitative echocardiography-based technique capable of noninvasively mapping cardiac electromechanical activation in three dimensions. The aim of this exploratory study was to investigate the EWI technique, sensitive to ventricular dyssynchrony, for informing CRT response on the day of implantation. METHODS: Forty-four patients with heart failure with left bundle branch block or right ventricular (RV) paced rhythm and decreased left ventricular ejection fraction (LVEF; mean, 25.3 ± 9.6%) underwent EWI without and with CRT within 24 hours of device implantation. Of those, 16 were also scanned while in left ventricular (LV) pacing. Improvement in LVEF at 3-, 6-, or 9-month follow-up defined (1) super-responders (ΔLVEF ≥ 20%), (2) responders (10% ≤ ΔLVEF < 20%), and (3) nonresponders (ΔLVEF ≤ 5%). Three-dimensionally rendered electromechanical maps were obtained under RV, LV, and biventricular CRT pacing conditions. Mean RV free wall and LV lateral wall activation times were computed. The percentage of resynchronized myocardium was measured by quantifying the percentage of the left ventricle activated within 120 msec of QRS onset. Correlations between percentage of resynchronized myocardium and type of CRT response were assessed. RESULTS: LV lateral wall activation time was significantly different (P ≤ .05) among all three pacing conditions in the 16 patients: LV lateral wall activation time with CRT in biventricular pacing (73.1 ± 17.6 msec) was lower compared with LV pacing (89.5 ± 21.5 msec) and RV pacing (120.3 ± 17.8 msec). Retrospective analysis showed that the percentage of resynchronized myocardium with CRT was a reliable response predictor within 24 hours of implantation for significantly (P ≤ .05) identifying super-responders (n = 7; 97.7 ± 1.9%) from nonresponders (n = 17; 89.9 ± 9.9%). CONCLUSION: Electromechanical activation mapping constitutes a valuable three-dimensional visualization tool within 24 hours of implantation and could potentially aid in the timely assessment of CRT response rates, including during implantation for adjustment of lead placement and pacing outcomes.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos , Humanos , Proyectos Piloto , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
2.
Ultrasound Med Biol ; 46(2): 405-414, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31767455

RESUMEN

Differentiation between epicardial and endocardial ventricular activation remains a challenge despite the latest technologies available. The aim of the present study was to develop a new tool method, based on electromechanical wave imaging (EWI), to improve arrhythmogenic substrate activation analysis. Experiments were conducted on left ventricles (LVs) of four isolated working mode swine hearts. The protocol aimed at demonstrating that different patterns of mechanical activation could be observed whether the ventricle was in sinus rhythm, paced from the epicardium or from the endocardium. A total of 72 EWI acquisitions were recorded on the anterior, lateral and posterior segments of the LV. A total of 54 loop records were blindly assigned to two readers. EWI sequences interpretations were correct in 89% of cases. The overall agreement rate between the two readers was 83%. When in a paced ventricle, the origin of the wave front was focal and originated from the endocardium or the epicardium. In sinus rhythm, wave front was global and activated within the entire endocardium toward the epicardium at a speed of 1.7 ± 0.28 m·s-1. Wave front speeds were respectively measured when the endocardium or the epicardium were paced at a speed of 1.1 ± 0.35 m·s-1 versus 1.3 ± 0.34 m·s-1 (p = NS). EWI activation mapping allows activation localization within the LV wall and calculation of the wave front propagation speed through the muscle. In the future, this technology could help localize activation within the LV thickness during complex ablation procedures.


Asunto(s)
Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/fisiopatología , Endocardio/diagnóstico por imagen , Endocardio/fisiopatología , Corazón/diagnóstico por imagen , Corazón/fisiopatología , Pericardio/diagnóstico por imagen , Pericardio/fisiopatología , Animales , Técnicas Electrofisiológicas Cardíacas , Porcinos , Ultrasonografía/métodos
3.
Comput Biol Med ; 113: 103382, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31476587

RESUMEN

Cardiac abnormalities, a major cause of morbidity and mortality, affect millions of people worldwide. Despite the urgent clinical need for early diagnosis, there is currently no noninvasive technique that can infer to the electrical function of the whole heart in 3D and thereby localize abnormalities at the point of care. Here we present a new method for noninvasive 4D mapping of the cardiac electromechanical activity in a single heartbeat for heart disease characterization such as arrhythmia and infarction. Our novel technique captures the 3D activation wave of the heart in vivo using high volume-rate (500 volumes per second) ultrasound with a 32 × 32 matrix array. Electromechanical activation maps are first presented in a normal and infarcted cardiac model in silico and in canine heart during pacing and re-entrant ventricular tachycardia in vivo. Noninvasive 4D electromechanical activation mapping in a healthy volunteer and a heart failure patient are also determined. The technique described herein allows for direct, simultaneous and noninvasive visualization of electromechanical activation in 3D, which provides complementary information on myocardial viability and/or abnormality to clinical imaging.


Asunto(s)
Arritmias Cardíacas , Ecocardiografía , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/fisiopatología , Procesamiento de Imagen Asistido por Computador , Animales , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/fisiopatología , Perros , Masculino
4.
Ultrasound Med Biol ; 44(11): 2241-2249, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30093340

RESUMEN

There is currently no established method for the non-invasive characterization of arrhythmia and differentiation between endocardial and epicardial triggers at the point of care. Electromechanical wave imaging (EWI) is a novel ultrasound-based imaging technique based on time-domain transient strain estimation that can map and characterize electromechanical activation in the heart in vivo. The objectives of this initial feasibility study were to determine that EWI is capable of differentiating between endocardial and epicardial sources of focal rhythm and, as a proof-of-concept, that EWI could characterize focal arrhythmia in one patient with premature ventricular contractions (PVCs) before radiofrequency (RF) ablation treatment. First, validation of EWI for differentiation of surface of origin was performed in seven (n = 7) adult dogs using four epicardial and four endocardial pacing protocols. Second, one (n = 1) adult patient diagnosed with PVC was imaged with EWI before the scheduled RF ablation procedure, and EWI results were compared with mapping procedure results. In dogs, EWI was capable of detecting whether pacing was of endocardial or epicardial origin in six of seven cases (86% success rate). In the PVC patient, EWI correctly identified both regions and surface of origin, as confirmed by results from the electrical mapping obtained from the RF ablation procedure. These results reveal that EWI can map the electromechanical activation across the myocardium and indicate that EWI could serve as a valuable pre-treatment planning tool in the clinic.


Asunto(s)
Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/fisiopatología , Anciano , Animales , Arritmias Cardíacas/cirugía , Ablación por Catéter , Modelos Animales de Enfermedad , Perros , Estudios de Factibilidad , Corazón/diagnóstico por imagen , Corazón/fisiopatología , Humanos , Reproducibilidad de los Resultados , Ultrasonografía/métodos
5.
Med Phys ; 44(9): 4766-4772, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28626939

RESUMEN

PURPOSE: Arrhythmias can be treated by ablating the heart tissue in the regions of abnormal contraction. The current clinical standard provides electroanatomic 3-D maps to visualize the electrical activation and locate the arrhythmogenic sources. However, the procedure is time-consuming and invasive. Electromechanical wave imaging is an ultrasound-based noninvasive technique that can provide 2-D maps of the electromechanical activation of the heart. In order to fully visualize the complex 3-D pattern of activation, several 2-D views are acquired and processed separately. They are then manually registered with a 3-D rendering software to generate a pseudo-3-D map. However, this last step is operator-dependent and time-consuming. METHODS: This paper presents a method to generate a full 3-D map of the electromechanical activation using multiple 2-D images. Two canine models were considered to illustrate the method: one in normal sinus rhythm and one paced from the lateral region of the heart. Four standard echographic views of each canine heart were acquired. Electromechanical wave imaging was applied to generate four 2-D activation maps of the left ventricle. The radial positions and activation timings of the walls were automatically extracted from those maps. In each slice, from apex to base, these values were interpolated around the circumference to generate a full 3-D map. RESULTS: In both cases, a 3-D activation map and a cine-loop of the propagation of the electromechanical wave were automatically generated. The 3-D map showing the electromechanical activation timings overlaid on realistic anatomy assists with the visualization of the sources of earlier activation (which are potential arrhythmogenic sources). The earliest sources of activation corresponded to the expected ones: septum for the normal rhythm and lateral for the pacing case. CONCLUSIONS: The proposed technique provides, automatically, a 3-D electromechanical activation map with a realistic anatomy. This represents a step towards a noninvasive tool to efficiently localize arrhythmias in 3-D.


Asunto(s)
Algoritmos , Sistema de Conducción Cardíaco/diagnóstico por imagen , Ultrasonografía , Animales , Arritmias Cardíacas/terapia , Perros , Corazón , Ventrículos Cardíacos , Humanos , Modelos Animales
6.
Ultrasound Med Biol ; 43(10): 2256-2268, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28778420

RESUMEN

Electromechanical wave imaging (EWI) is an ultrasound-based technique that can non-invasively map the transmural electromechanical activation in all four cardiac chambers in vivo. The objective of this study was to determine the reproducibility and angle independence of EWI for the assessment of electromechanical activation during normal sinus rhythm (NSR) in healthy humans. Acquisitions were performed transthoracically at 2000 frames/s on seven healthy human hearts in parasternal long-axis, apical four- and two-chamber views. EWI data was collected twice successively in each view in all subjects, while four successive acquisitions were obtained in one case. Activation maps were generated and compared (i) within the same acquisition across consecutive cardiac cycles; (ii) within same view across successive acquisitions; and (iii) within equivalent left-ventricular regions across different views. EWI was capable of characterizing electromechanical activation during NSR and of reliably obtaining similar patterns of activation. For consecutive heart cycles, the average 2-D correlation coefficient between the two isochrones across the seven subjects was 0.9893, with a mean average activation time fluctuation in LV wall segments across acquisitions of 6.19%. A mean activation time variability of 12% was obtained across different views with a measurement bias of only 3.2 ms. These findings indicate that EWI can map the electromechanical activation during NSR in human hearts in transthoracic echocardiography in vivo and results in reproducible and angle-independent activation maps.


Asunto(s)
Corazón/fisiología , Ultrasonografía/métodos , Adulto , Corazón/diagnóstico por imagen , Humanos , Masculino , Valores de Referencia , Reproducibilidad de los Resultados , Adulto Joven
7.
Ultrasound Med Biol ; 40(1): 177-87, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24239363

RESUMEN

Electromechanical wave imaging (EWI) has been show capable of directly and entirely non-invasively mapping the trans mural electromechanical activation in all four cardiac chambers in vivo. In this study, we assessed EWI repeatability and reproducibility, as well as its capability of localizing electronic and, for the first time, biological pacing locations in closed-chest, conscious canines. Electromechanical activation was obtained in six conscious animals during normal sinus rhythm (NSR) and idioventricular rhythms occurring in dogs with complete heart block instrumented with electronic and biologic pacemakers (EPM and BPM respectively). After atrioventricular node ablation, dogs were implanted with an EPM in the right ventricular (RV) endocardial apex (n = 4) and two additionally received a BPM at the left ventricular (LV) epicardial base (n = 2). EWI was performed trans thoracically during NSR, BPM and EPM pacing, in conscious dogs, using an unfocused transmit sequence at 2000 frames/s. During NSR, the EW originated at the right atrium (RA), propagated to the left atrium (LA) and emerged from multiple sources in both ventricles. During EPM, the EW originated at the RV apex and propagated throughout both ventricles. During BPM, the EW originated from the LV basal lateral wall and subsequently propagated throughout the ventricles. EWI differentiated BPM from EPM and NSR and identified the distinct pacing origins. Isochrone comparison indicated that EWI was repeatable and reliable. These findings thus indicate the potential for EWI to serve as a simple, non-invasive and direct imaging technology for mapping and characterizing arrhythmias as well as the treatments thereof.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Estimulación Cardíaca Artificial , Ecocardiografía/métodos , Acoplamiento Excitación-Contracción/fisiología , Sistema de Conducción Cardíaco/fisiología , Corazón/fisiología , Contracción Miocárdica/fisiología , Animales , Perros , Interpretación de Imagen Asistida por Computador/métodos , Masculino