Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 145
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Small ; : e2401229, 2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38733235

RESUMEN

The great potential of K1/2Bi1/2TiO3 (KBT) for dielectric energy storage ceramics is impeded by its low dielectric breakdown strength, thereby limiting its utilization of high polarization. This study develops a novel composition, 0.83KBT-0.095Na1/2Bi1/2ZrO3-0.075 Bi0.85Nd0.15FeO3 (KNBNTF) ceramics, demonstrating outstanding energy storage performance under high electric fields up to 425 kV cm-1: a remarkable recoverable energy density of 7.03 J cm-3, and a high efficiency of 86.0%. The analysis reveals that the superior dielectric breakdown resistance arises from effective mitigation of space charge accumulation at the interface, influenced by differential dielectric and conductance behaviors between grains and grain boundaries. Electric impedance spectra confirm the significant suppression of space charge accumulation in KNBNTF, attributable to the co-introduction of Na1/2Bi1/2ZrO3 and Bi0.85Nd0.15FeO3. Phase-field simulations reveal the emergence of a trans-granular breakdown mode in KNBNTF resulting from the mitigated interfacial polarization, impeding breakdown propagation and increasing dielectric breakdown resistance. Furthermore, KNBNTF exhibits a complex local polarization and enhances the relaxor features, facilitating high field-induced polarization and establishing favorable conditions for exceptional energy storage performance. Therefore, the proposed strategy is a promising design pathway for tailoring dielectric ceramics in energy storage applications.

2.
NMR Biomed ; : e5168, 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38716493

RESUMEN

The increasing signal-to-noise ratio (SNR) is the main reason to use ultrahigh field MRI. Here, we investigate the dependence of the SNR on the magnetic field strength, especially for small animal applications, where small surface coils are used and coil noise cannot be ignored. Measurements were performed at five field strengths from 3 to 14.1 T, using 2.2-cm surface coils with an identical coil design for transmit and receive on two water samples with and without salt. SNR was measured in a series of spoiled gradient echo images with varying flip angle and corrected for saturation based on a series of flip angle and T1 measurements. Furthermore, the noise figure of the receive chain was determined and eliminated to remove instrument dependence. Finally, the coil sensitivity was determined based on the principle of reciprocity to obtain a measure for ultimate SNR. Before coil sensitivity correction, the SNR increase in nonconductive samples is highly supralinear with B0 1.6-2.7, depending on distance to the coil, while in the conductive sample, the growth is smaller, being around linear close to the surface coil and increasing up to a B0 2.0 dependence when moving away from the coil. After sensitivity correction, the SNR increase is independent of loading with B0 2.1. This study confirms the supralinear increase of SNR with increasing field strengths. Compared with most human measurements with larger coil sizes, smaller surface coils, as mainly used in animal studies, have a higher contribution of coil noise and thus a different behavior of SNR at high fields.

3.
J Cardiovasc Magn Reson ; 26(2): 101052, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38936803

RESUMEN

BACKGROUND: In-vivo diffusion tensor cardiovascular magnetic resonance (DT-CMR) is an emerging technique for microstructural tissue characterization in the myocardium. Most studies are performed at 3T, where higher signal-to-noise ratio (SNR) should benefit this signal-starved method. However, a few studies have suggested that DT-CMR is possible at 1.5T, where echo planar imaging artifacts may be less severe and 1.5T hardware is more widely available. METHODS: We recruited 20 healthy volunteers and performed mid-ventricular short-axis DT-CMR at 1.5T and 3T. Acquisitions were performed at peak systole and end-diastole using both stimulated echo acquisition mode (STEAM) and motion-compensated spin-echo (MCSE) sequences at matched spatial resolutions. DT-CMR parameters were averaged over the left ventricle and compared between 1.5T and 3T sequences using both datasets with and without the blow reference data included. RESULTS: Eleven (1.5T) and 12 (3T) diastolic MCSE acquisitions were rejected as the helix angle (HA) demonstrated <50% normal appearance circumferentially or the acquisition was abandoned due to poor image quality; a maximum of one acquisition was rejected for other datasets. Subjective HA map quality was significantly better at 3T than 1.5T for STEAM (p < 0.05), but not for MCSE and other DT-CMR quality measures were consistent with improvements in STEAM at 3T over 1.5T. When blow data were excluded, no significant differences in mean diffusivity were observed between field strengths, but fractional anisotropy was significantly higher at 1.5T than 3T for STEAM systole (p < 0.05). Absolute second eigenvector orientation (E2A, sheetlet angle) was significantly higher at 1.5T than 3T for MCSE systole and STEAM diastole, but significantly lower for STEAM systole (all p < 0.05). Transmural HA distribution was less steep at 1.5T than 3T for STEAM diastole data (p < 0.05). SNR was higher at 3T than 1.5T for all acquisitions (p < 0.05). CONCLUSION: While 3T provides benefits in terms of SNR, both STEAM and MCSE can be performed at 1.5T. However, MCSE is unreliable in diastole at both field strengths and STEAM benefits from the improved SNR at 3T over 1.5T. Future clinical research studies may be able to leverage the wider availability of 1.5T CMR hardware where MCSE acquisitions are desirable.

4.
J Cardiovasc Magn Reson ; 26(1): 100005, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38211656

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) imaging is an important tool for evaluating the severity of aortic stenosis (AS), co-existing aortic disease, and concurrent myocardial abnormalities. Acquiring this additional information requires protocol adaptations and additional scanner time, but is not necessary for the majority of patients who do not have AS. We observed that the relative signal intensity of blood in the ascending aorta on a balanced steady state free precession (bSSFP) 3-chamber cine was often reduced in those with significant aortic stenosis. We investigated whether this effect could be quantified and used to predict AS severity in comparison to existing gold-standard measurements. METHODS: Multi-centre, multi-vendor retrospective analysis of patients with AS undergoing CMR and transthoracic echocardiography (TTE). Blood signal intensity was measured in a ∼1 cm2 region of interest (ROI) in the aorta and left ventricle (LV) in the 3-chamber bSSFP cine. Because signal intensity varied across patients and scanner vendors, a ratio of the mean signal intensity in the aorta ROI to the LV ROI (Ao:LV) was used. This ratio was compared using Pearson correlations against TTE parameters of AS severity: aortic valve peak velocity, mean pressure gradient and the dimensionless index. The study also assessed whether field strength (1.5 T vs. 3 T) and patient characteristics (presence of bicuspid aortic valves (BAV), dilated aortic root and low flow states) altered this signal relationship. RESULTS: 314 patients (median age 69 [IQR 57-77], 64% male) who had undergone both CMR and TTE were studied; 84 had severe AS, 78 had moderate AS, 66 had mild AS and 86 without AS were studied as a comparator group. The median time between CMR and TTE was 12 weeks (IQR 4-26). The Ao:LV ratio at 1.5 T strongly correlated with peak velocity (r = -0.796, p = 0.001), peak gradient (r = -0.772, p = 0.001) and dimensionless index (r = 0.743, p = 0.001). An Ao:LV ratio of < 0.86 was 84% sensitive and 82% specific for detecting AS of any severity and a ratio of 0.58 was 83% sensitive and 92% specific for severe AS. The ability of Ao:LV ratio to predict AS severity remained for patients with bicuspid aortic valves, dilated aortic root or low indexed stroke volume. The relationship between Ao:LV ratio and AS severity was weaker at 3 T. CONCLUSIONS: The Ao:LV ratio, derived from bSSFP 3-chamber cine images, shows a good correlation with existing measures of AS severity. It demonstrates utility at 1.5 T and offers an easily calculable metric that can be used at the time of scanning or automated to identify on an adaptive basis which patients benefit from dedicated imaging to assess which patients should have additional sequences to assess AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Imagen por Resonancia Cinemagnética , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Función Ventricular Izquierda , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Masculino , Estudios Retrospectivos , Anciano , Persona de Mediana Edad , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/patología , Válvula Aórtica/anomalías , Reproducibilidad de los Resultados , Aorta/diagnóstico por imagen , Aorta/fisiopatología , Interpretación de Imagen Asistida por Computador , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Flujo Sanguíneo Regional , Estados Unidos
5.
J Appl Microbiol ; 135(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38906847

RESUMEN

AIM: Ohmic heating (OH) (i.e. heating by electric field) more effectively kills bacterial spores than traditional wet heating, yet its mechanism remains poorly understood. This study investigates the accelerated spore inactivation mechanism using genetically modified spores. METHODS AND RESULTS: We investigated the effects of OH and conventional heating (CH) on various genetically modified strains of Bacillus subtilis: isogenic PS533 (wild type_1), PS578 [lacking spores' α/ß-type small acid-soluble proteins (SASP)], PS2318 (lacking recA, encoding a DNA repair protein), isogenic PS4461 (wild type_2), and PS4462 (having the 2Duf protein in spores, which increases spore wet heat resistance and decreases spore inner membrane fluidity). Removal of SASP brought the inactivation profiles of OH and CH closer, suggesting the interaction of these proteins with the field. However, the reemergence of a difference between CH and OH killing for SASP-deficient spores at the highest tested field strength suggested there is also interaction of the field with another spore core component. Additionally, RecA-deficient spores yielded results like those with the wild-type spores for CH, while the OH resistance of this mutant increased at the lower tested temperatures, implying that RecA or DNA are a possible additional target for the electric field. Addition of the 2Duf protein markedly increased spore resistance both to CH and OH, although some acceleration of killing was observed with OH at 50 V/cm. CONCLUSIONS: In summary, both membrane fluidity and interaction of the spore core proteins with electric field are key factors in enhanced spore killing with electric field-heat combinations.


Asunto(s)
Bacillus subtilis , Proteínas Bacterianas , Calor , Rec A Recombinasas , Esporas Bacterianas , Esporas Bacterianas/efectos de la radiación , Esporas Bacterianas/genética , Bacillus subtilis/genética , Bacillus subtilis/fisiología , Bacillus subtilis/metabolismo , Rec A Recombinasas/genética , Rec A Recombinasas/metabolismo , Proteínas Bacterianas/genética , Proteínas Bacterianas/metabolismo , Calefacción , Proteínas de la Membrana/metabolismo , Proteínas de la Membrana/genética
6.
Bioelectromagnetics ; 45(2): 82-93, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37860924

RESUMEN

Conductive dental implants are commonly used in restorative therapy to replace missing teeth in patients. Ensuring the radiofrequency (RF) safety of these patients is crucial when performing 7 T magnetic resonance scans of their heads. This study aimed to investigate RF-induced heating inside the human head with dental implants at 7 T. Dental implants and their attachments were fabricated and integrated into an anatomical head model, creating different measurement configurations (MCs). Numerical simulations were conducted using a 7 T transmit coil loaded with the anatomical head model, both with and without dental implants. The maximum temperatures inside the head for various MCs were computed using the maximum permissible input powers (MPIPs) obtained without dental implants and compared with published limits. Additionally, the MPIPs with dental implants were calculated for scenarios where the temperature limits were exceeded. The maximum temperatures observed inside the head ranged from 38.4°C to 39.6°C. The MPIPs in the presence of dental implants were 81.9%-97.3% of the MPIPs in the absence of dental implants for scenarios that exceeded the regulatory limit. RF-induced heating effect of the dental implants was not significant. The safe scanning condition in terms of RF exposure was achievable for patients with dental implants. For patients with conductive dental implants of unknown configuration, it is recommended to reduce the input power by 18.1% of MPIP without dental implants to ensure RF safety.


Asunto(s)
Implantes Dentales , Calor , Humanos , Calefacción , Temperatura , Imagen por Resonancia Magnética , Ondas de Radio/efectos adversos , Fantasmas de Imagen
7.
Skeletal Radiol ; 53(9): 1751-1760, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38381197

RESUMEN

This narrative review explores recent advancements and applications of modern low-field (≤ 1 Tesla) magnetic resonance imaging (MRI) in musculoskeletal radiology. Historically, high-field MRI systems (1.5 T and 3 T) have been the standard in clinical practice due to superior image resolution and signal-to-noise ratio. However, recent technological advancements in low-field MRI offer promising avenues for musculoskeletal imaging. General principles of low-field MRI systems are being introduced, highlighting their strengths and limitations compared to high-field counterparts. Emphasis is placed on advancements in hardware design, including novel magnet configurations, gradient systems, and radiofrequency coils, which have improved image quality and reduced susceptibility artifacts particularly in musculoskeletal imaging. Different clinical applications of modern low-field MRI in musculoskeletal radiology are being discussed. The diagnostic performance of low-field MRI in diagnosing various musculoskeletal pathologies, such as ligament and tendon injuries, osteoarthritis, and cartilage lesions, is being presented. Moreover, the discussion encompasses the cost-effectiveness and accessibility of low-field MRI systems, making them viable options for imaging centers with limited resources or specific patient populations. From a scientific standpoint, the amount of available data regarding musculoskeletal imaging at low-field strengths is limited and often several decades old. This review will give an insight to the existing literature and summarize our own experiences with a modern low-field MRI system over the last 3 years. In conclusion, the narrative review highlights the potential clinical utility, challenges, and future directions of modern low-field MRI, offering valuable insights for radiologists and healthcare professionals seeking to leverage these advancements in their practice.


Asunto(s)
Imagen por Resonancia Magnética , Enfermedades Musculoesqueléticas , Humanos , Imagen por Resonancia Magnética/métodos , Enfermedades Musculoesqueléticas/diagnóstico por imagen , Diseño de Equipo , Sistema Musculoesquelético/diagnóstico por imagen , Relación Señal-Ruido
8.
J Magn Reson Imaging ; 57(4): 1250-1261, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35767224

RESUMEN

BACKGROUND: Left ventricular (LV) strain measurements can be derived using cardiac MRI from routinely acquired balanced steady-state free precession (bSSFP) cine images. PURPOSE: To compare the interfield strength agreement of global systolic strain, peak strain rates and artificial intelligence (AI) landmark-based global longitudinal shortening at 1.5 T and 3 T. STUDY TYPE: Prospective. SUBJECTS: A total of 22 healthy individuals (mean age 36 ± 12 years; 45% male) completed two cardiac MRI scans at 1.5 T and 3 T in a randomized order within 30 minutes. FIELD STRENGTH/SEQUENCE: bSSFP cine images at 1.5 T and 3 T. ASSESSMENT: Two software packages, Tissue Tracking (cvi42, Circle Cardiovascular Imaging) and QStrain (Medis Suite, Medis Medical Imaging Systems), were used to derive LV global systolic strain in the longitudinal, circumferential and radial directions and peak (systolic, early diastolic, and late diastolic) strain rates. Global longitudinal shortening and mitral annular plane systolic excursion (MAPSE) were measured using an AI deep neural network model. STATISTICAL TESTS: Comparisons between field strengths were performed using Wilcoxon signed-rank test (P value < 0.05 considered statistically significant). Agreement was determined using intraclass correlation coefficients (ICCs) and Bland-Altman plots. RESULTS: Minimal bias was seen in all strain and strain rate measurements between field strengths. Using Tissue Tracking, strain and strain rate values derived from long-axis images showed poor to fair agreement (ICC range 0.39-0.71), whereas global longitudinal shortening and MAPSE showed good agreement (ICC = 0.81 and 0.80, respectively). Measures derived from short-axis images showed good to excellent agreement (ICC range 0.78-0.91). Similar results for the agreement of strain and strain rate measurements were observed with QStrain. CONCLUSION: The interfield strength agreement of short-axis derived LV strain and strain rate measurements at 1.5 T and 3 T was better than those derived from long-axis images; however, the agreement of global longitudinal shortening and MAPSE was good. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Inteligencia Artificial , Imagen por Resonancia Cinemagnética , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Ventrículos Cardíacos , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética/métodos , Estudios Prospectivos , Reproducibilidad de los Resultados , Función Ventricular Izquierda
9.
MAGMA ; 36(3): 355-373, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37171689

RESUMEN

OBJECT: Lower-field MR is reemerging as a viable, potentially cost-effective alternative to high-field MR, thanks to advances in hardware, sequence design, and reconstruction over the past decades. Evaluation of lower field strengths, however, is limited by the availability of lower-field systems on the market and their considerable procurement costs. In this work, we demonstrate a low-cost, temporary alternative to purchasing a dedicated lower-field MR system. MATERIALS AND METHODS: By ramping down an existing clinical 3 T MRI system to 0.75 T, proton signals can be acquired using repurposed 13C transmit/receive hardware and the multi-nuclei spectrometer interface. We describe the ramp-down procedure and necessary software and hardware changes to the system. RESULTS: Apart from presenting system characterization results, we show in vivo examples of cardiac cine imaging, abdominal two- and three-point Dixon-type water/fat separation, water/fat-separated MR Fingerprinting, and point-resolved spectroscopy. In addition, the ramp-down approach allows unique comparisons of, e.g., gradient fidelity of the same MR system operated at different field strengths using the same receive chain, gradient coils, and amplifiers. DISCUSSION: Ramping down an existing MR system may be seen as a viable alternative for lower-field MR research in groups that already own multi-nuclei hardware and can also serve as a testing platform for custom-made multi-nuclei transmit/receive coils.


Asunto(s)
Imagen por Resonancia Magnética , Programas Informáticos , Imagen por Resonancia Magnética/métodos , Protones
10.
MAGMA ; 36(5): 725-735, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36933090

RESUMEN

OBJECTIVE: This study presents an extended evaluation of a numerical approach to simulate artifacts of metallic implants in an MR environment. METHODS: The numerical approach is validated by comparing the artifact shape of the simulations and measurements of two metallic orthopedic implants at three different field strengths (1.5 T, 3 T, and 7 T). Furthermore, this study presents three additional use cases of the numerical simulation. The first one shows how numerical simulations can improve the artifact size evaluation according to ASTM F2119. The second use case quantifies the influence of different imaging parameters (TE and bandwidth) on the artifact size. Finally, the third use case shows the potential of performing human model artifact simulations. RESULTS: The numerical simulation approach shows a dice similarity coefficient of 0.74 between simulated and measured artifact sizes of metallic implants. The alternative artifact size calculation method presented in this study shows that the artifact size of the ASTM-based method is up to 50% smaller for complex shaped implants compared to the numerical-based approach. CONCLUSION: In conclusion, the numerical approach could be used in the future to extend MR safety testing according to a revision of the ASTM F2119 standard and for design optimization during the development process of implants.


Asunto(s)
Artefactos , Prótesis e Implantes , Humanos , Simulación por Computador , Imagen por Resonancia Magnética/métodos
11.
Adv Exp Med Biol ; 1424: 281-288, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37486505

RESUMEN

The purpose of this chapter is the mathematical study of the perturbation of a homogeneous static magnetic field caused by the embedding of a red blood cell. Analytical expressions for the magnetic potential and the magnetic strength vector are derived. From the obtained results, it emerges that the magnetic field inside the red blood cell is not uniform and the magnitude depends on the orientation of the erythrocyte. The expressions for the magnetic field quantities are significant in applications such as the magnetic resonance imaging and in the magnetic resonance spectroscopy.


Asunto(s)
Eritrocitos , Campos Magnéticos , Matemática , Espectroscopía de Resonancia Magnética , Imagen por Resonancia Magnética
12.
Sensors (Basel) ; 23(4)2023 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-36850372

RESUMEN

The paper considers non-destructive testing (NTDs) as a means to solve the flaw detection problems of magnetic products. It proposes a new probe-coil magnetic-field NDT, not requiring the pre-magnetization of the test object material, which is mandatory for all conventional magnetic flaw detection techniques. A new bifactor excitation of the fluxgate sensor's sensitive element, based on double µ-transformation through the simultaneous activation of magnetic-modulating and electromagnetic-acoustic effects, is theoretically justified. The physical processes underlying the proposed technique are considered in detail, and a scheme for its practical implementation is described. The authors provide a variant of the new fluxgate's original design, implementing the proposed excitation technique. The specifics of implementing the fluxgate operating modes are analyzed, testifying to the possibility of detecting a given class of flaws with the required coverage as well as ensuring the required diagnostic resolution during flaw detection, which, in fact, indicates a more reliable identification of both the flaw type and location. Herewith, the new fluxgate type features the advantages of improved functionality and lower cost due to its simple design. The paper also considers a method to experimentally study the capabilities of the proposed fluxgate sensor with a new bifactor excitation in detail. The results of the experimental study into its key specifications are provided, confirming its high resolution, narrower zone of uncertainty, and the possibility of detecting smaller flaws at greater depths compared to available analogs.

13.
J Med Syst ; 47(1): 107, 2023 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-37851155

RESUMEN

The use of two personal dosimeters, one worn over and one worn under a protective apron, provides the best estimate of effective dose. However, inappropriate positioning of dosimeters is a common occurrence, resulting in abnormally high or low radiation exposure records. Although such incorrect positioning can be identified by radiation exposure records, doing so is time-consuming and labor-intensive for administrators. Therefore, a system that can identify incorrect locations of dosimeters without burdening administrators must be developed. In this study, we developed a radio frequency identification (RFID) gate system that can differentiate between two RFID-tagged dosimeters placed over and under a metal apron and identify misused dosimeters. To simulate the position of the RFID-tagged dosimeters, we designed four dosimeter-wearing classes, including "proper use" and three types of "misuse" (i.e., "reversed," "both under," and "both over"). When the system predicts "misuse" based on the tag reading, the worker is alerted with lights and alarms. The system performance was evaluated using a confusion matrix, with an overall accuracy of 97.75%, demonstrating high classification performance. The safety of the system against life support devices was also investigated, demonstrating that they were not affected by the electric field at 0.3 m or more from the antenna of the system under any transmit powers tested. This RFID gate system is highly capable of identifying incorrectly positioned dosimeters, enabling real-time monitoring of dosimeters to manage their positioning.


Asunto(s)
Dispositivo de Identificación por Radiofrecuencia , Humanos , Dosímetros de Radiación
14.
Magn Reson Med ; 88(5): 2131-2138, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35849739

RESUMEN

PURPOSE: The SNR at the center of a spherical phantom of known electrical properties was measured in quasi-identical experimental conditions as a function of magnetic field strength between 3 T and 11.7 T. METHODS: The SNR was measured at the center of a spherical water saline phantom with a gradient-recalled echo sequence. Measurements were performed at NeuroSpin at 3, 7, and 11.7 T. The phantom was then shipped to Maastricht University and then to the University of Minnesota for additional data points at 7, 9.4, and 10.5 T. Experiments were carried out with the exact same type of birdcage volume coil (except at 3 T, where a similar coil was used) to attempt at isolating the evolution of SNR with field strength alone. Phantom electrical properties were characterized over the corresponding frequency range. RESULTS: Electrical properties were found to barely vary over the frequency range. Removing the influence of the flip-angle excitation inhomogeneity was crucial, as expected. After such correction, measurements revealed a gain of SNR growing as B0 1.94 ± 0.16 compared with B0 2.13 according to ultimate intrinsic SNR theory. CONCLUSIONS: By using quasi-identical experimental setups (RF volume coil, phantom, electrical properties, and protocol), this work reports experimental data between 3 T and 11.7 T, enabling the comparison with SNR theories in which conductivity and permittivity can be assumed to be constant with respect to field strength. According to ultimate SNR theory, these results can be reasonably extrapolated to the performance of receive arrays with greater than about 32 elements for central SNR in the same spherical phantom.


Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Humanos , Campos Magnéticos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Relación Señal-Ruido
15.
Magn Reson Med ; 88(1): 309-321, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35373857

RESUMEN

PURPOSE: To evaluate the feasibility of motion correction for sodium (23 Na) MRI based on interleaved acquired 3D proton (1 H) navigator images. METHODS: A 3D radial density-adapted sequence for interleaved 23 Na/1 H MRI was implemented on a 7 Tesla whole-body MRI system. The 1 H data obtained during the 23 Na acquisition were used to reconstruct 140 navigator image volumes with a nominal spatial resolution of (2.5 mm)3 and a temporal resolution of 6 s. The motion information received from co-registration was then used to correct the 23 Na image dataset, which also had a nominal spatial resolution of (2.5 mm)3 . The approach was evaluated on six healthy volunteers, whose motion during the scans had different intensities and characteristics. RESULTS: Interleaved acquisition of two nuclei did not show any relevant influence on image quality (SNR of 13.0 for interleaved versus 13.2 for standard 23 Na MRI and 176.4 for interleaved versus 178.0 for standard 1 H MRI). The applied motion correction increased the consistency between two consecutive scans for all examined volunteers and improved the image quality for all kinds of motion. The SD of the differences ranged between 2.30% and 6.96% for the uncorrected and between 2.13% and 2.67% for the corrected images. CONCLUSION: The feasibility of interleaved acquired 1 H navigator images to be used for retrospective motion correction of 23 Na images was successfully demonstrated. The approach neither affected the 23 Na image quality nor elongated the scan time and can therefore be an important tool to improve the accuracy of quantitative 23 Na MRI.


Asunto(s)
Imagen por Resonancia Magnética , Protones , Encéfalo/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Movimiento (Física) , Estudios Retrospectivos , Sodio
16.
NMR Biomed ; 35(5): e4653, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34816501

RESUMEN

Dynamic susceptibility contrast (DSC) MRI is clinically used to measure brain perfusion by monitoring the dynamic passage of a bolus of contrast agent through the brain. For quantitative analysis of the DSC images, the arterial input function is required. It is known that the original assumption of a linear relation between the R2(*) relaxation and the arterial contrast agent concentration is invalid, although the exact relation is as of yet unknown. Studying this relation in vitro is time-consuming, because of the widespread variations in field strengths, MRI sequences, contrast agents, and physiological conditions. This study aims to simulate the R2(*) versus contrast concentration relation under varying physiological and technical conditions using an adapted version of an open-source simulation tool. The approach was validated with previously acquired data in human whole blood at 1.5 T by means of a gradient-echo sequence (proof-of-concept). Subsequently, the impact of hematocrit, field strength, and oxygen saturation on this relation was studied for both gradient-echo and spin-echo sequences. The results show that for both gradient-echo and spin-echo sequences, the relaxivity increases with hematocrit and field strength, while the hematocrit dependency was nonlinear for both types of MRI sequences. By contrast, oxygen saturation has only a minor effect. In conclusion, the simulation setup has proven to be an efficient method to rapidly calibrate and estimate the relation between R2(*) and gadolinium concentration in whole blood. This knowledge will be useful in future clinical work to more accurately retrieve quantitative information on brain perfusion.


Asunto(s)
Medios de Contraste , Gadolinio DTPA , Hematócrito , Humanos , Campos Magnéticos , Imagen por Resonancia Magnética/métodos
17.
NMR Biomed ; 35(12): e4806, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35892310

RESUMEN

Apparent tissue sodium concentrations (aTSCs) determined by 23 Na brain magnetic resonance imaging (MRI) have the potential to serve as a biomarker in pathologies such as multiple sclerosis (MS). However, the quantification is hindered by the intrinsically low signal-to-noise ratio of 23 Na MRI. The purpose of this study was to improve the accuracy and reliability of quantitative 23 Na brain MRI by implementing a dedicated postprocessing pipeline and to evaluate the applicability of the developed approach for the examination of MS patients. 23 Na brain MRI measurements of 13 healthy volunteers and 17 patients with secondary progressive multiple sclerosis (SPMS) were performed at 7 T using a dual-tuned 23 Na/1 H birdcage coil with a receive-only 32-channel phased array. The aTSC values were determined for normal appearing white matter (NAWM) and normal appearing gray matter (NAGM) in healthy subjects and SPMS patients. Signal intensities were normalized using the mean cerebrospinal fluid (CSF) sodium concentration determined in 37 separate patients receiving a spinal tap for routine diagnostic purposes. Five volunteers underwent MRI examinations three times in a row to assess repeatability. Coefficients of variation (CoVs) were used to quantify the repeatability of the proposed method. aTSC values were compared regarding brain regions and subject cohort using the paired-samples Wilcoxon rank-sum test. Laboratory CSF sodium concentration did not differ significantly between patients without and with MS (p = 0.42). The proposed quantification workflow for 23 Na MRI was highly repeatable with CoVs averaged over all five volunteers of 1.9% ± 0.9% for NAWM and 2.2% ± 1.6% for NAGM. Average NAWM aTSC was significantly higher in patients with SPMS compared with the control group (p = 0.009). Average NAGM aTSC did not differ significantly between healthy volunteers and MS patients (p = 0.98). The proposed postprocessing pipeline shows high repeatability and the results can serve as a baseline for further studies establishing 23 Na brain MRI as a biomarker in diseases such as MS.


Asunto(s)
Esclerosis Múltiple Crónica Progresiva , Esclerosis Múltiple , Humanos , Esclerosis Múltiple Crónica Progresiva/diagnóstico por imagen , Esclerosis Múltiple Crónica Progresiva/patología , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Sodio , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Biomarcadores
18.
MAGMA ; 35(3): 485-497, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34655346

RESUMEN

OBJECTIVE: This study presents the development and evaluation of a numerical approach to simulate artifacts of metallic implants in an MR environment that can be applied to improve the testing procedure for MR image artifacts in medical implants according to ASTM F2119. METHODS: The numerical approach is validated by comparing simulations and measurements of two metallic test objects made of titanium and stainless steel at three different field strengths (1.5T, 3T and 7T). The difference in artifact size and shape between the simulated and measured artifacts were evaluated. A trend analysis of the artifact sizes in relation to the field strength was performed. RESULTS: The numerical simulation approach shows high similarity (between 75% and 84%) of simulated and measured artifact sizes of metallic implants. Simulated and measured artifact sizes in relation to the field strength resulted in a calculation guideline to determine and predict the artifact size at one field strength (e.g., 3T or 7T) based on a measurement that was obtained at another field strength only (e.g. 1.5T). CONCLUSION: This work presents a novel tool to improve the MR image artifact testing procedure of passive medical implants. With the help of this tool detailed artifact investigations can be performed, which would otherwise only be possible with substantial measurement effort on different MRI systems and field strengths.


Asunto(s)
Artefactos , Prótesis e Implantes , Imagen por Resonancia Magnética/métodos , Titanio
19.
Radiologe ; 62(5): 410-417, 2022 May.
Artículo en Alemán | MEDLINE | ID: mdl-35416477

RESUMEN

BACKGROUND: Magnetic resonance imaging (MRI) plays a crucial role in musculoskeletal imaging. The high prevalence and pain-related suffering of patients pose a particular challenge concerning availability and turnover times, respectively. Low-field (≤ 1.0 T) MRI has the potential to fulfill these needs. However, during the past three decades, high field systems have increasingly replaced low field systems because of their limitations in image quality. Recent technological advancements in high-performance hard- and software promise musculoskeletal imaging with adequate quality at lower field strengths for several regions and indications. OBJECTIVES: The goal is to provide insight into the advantages and disadvantages of low-field musculoskeletal imaging, discuss the current literature, and include our first experiences with a modern 0.55 T MRI. MATERIALS AND METHODS: This review is based on research in various literature databases and our own musculoskeletal imaging experiences with a modern 0.55 T scanner. CONCLUSION: Most publications pertaining to musculoskeletal imaging at low-field strength MRI are outdated, and studies regarding the diagnostic performance of modern low-field MRI systems are needed. These new systems may complement existing high-field systems and make MRI more accessible, even in low-income countries. From our own experience, modern low-field MRI seems to be adequate in musculoskeletal imaging, especially in acute injuries.


Asunto(s)
Imagen por Resonancia Magnética , Sistema Musculoesquelético , Humanos , Imagen por Resonancia Magnética/métodos , Sistema Musculoesquelético/diagnóstico por imagen , Programas Informáticos
20.
Radiologe ; 62(5): 418-428, 2022 May.
Artículo en Alemán | MEDLINE | ID: mdl-35416476

RESUMEN

BACKGROUND: Lung magnetic resonance imaging (MRI) examinations are challenging and have not become established in the routine clinical setting. Recent developments in low-field MRI, combined with computer-assisted algorithms for acquisition and evaluation, promise new perspectives for imaging of pulmonary diseases. OBJECTIVES: This review aims to inform about the physical advantages of low-field MRI for imaging the lungs, provide a review of the sparse literature, and present first results from a new low-field MRI scanner. MATERIALS AND METHODS: This article provides information on the physical principles, an review of the literature, and our first experiences in lung imaging on a modern 0.55 T MRI. CONCLUSION: Low-field MRI (< 1 T) may have technical and economic advantages over higher field strength MRI in lung imaging. The physical preconditions of low-field MRI are advantageous for imaging the lungs due to reduced susceptibility effects, increased transversal relaxation times, and lower specific absorption rates. The lower investment and operating costs may enable increased availability and sustainability. Combining modern sequences and computer-based image processing may expand beyond morphological imaging by providing spatially and temporally resolved functional examinations of the lung parenchyma without ionizing radiation. In critical scenarios, like screening and short-term follow-up examinations, and patients at risk, low-field MRI may bridge the gap. These indications may include acute and chronic pulmonary diseases in pediatric patients and suspected pulmonary embolisms in pregnant women.


Asunto(s)
Enfermedades Pulmonares , Imagen por Resonancia Magnética , Niño , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Pulmón/diagnóstico por imagen , Pulmón/patología , Enfermedades Pulmonares/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Embarazo , Tórax
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA