Sensors (Basel) ; 21(5)2021 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-33806584

RESUMEN

Ion-sensitive field-effect transistors (ISFETs) form a high sensitivity and scalable class of sensors, compatible with advanced complementary metal-oxide semiconductor (CMOS) processes. Despite many previous demonstrations about their merits as low-power integrated sensors, very little is known about their noise characterization when being operated in a liquid gate configuration. The noise characteristics in various regimes of their operation are important to select the most suitable conditions for signal-to-noise ratio (SNR) and power consumption. This work reports systematic DC, transient, and noise characterizations and models of a back-end of line (BEOL)-modified foundry-made ISFET used as pH sensor. The aim is to determine the sensor sensitivity and resolution to pH changes and to calibrate numerical and lumped element models, capable of supporting the interpretation of the experimental findings. The experimental sensitivity is approximately 40 mV/pH with a normalized resolution of 5 mpH per µm2, in agreement with the literature state of the art. Differences in the drain current noise spectra between the ISFET and MOSFET configurations of the same device at low currents (weak inversion) suggest that the chemical noise produced by the random binding/unbinding of the H+ ions on the sensor surface is likely the dominant noise contribution in this regime. In contrast, at high currents (strong inversion), the two configurations provide similar drain noise levels suggesting that the noise originates in the underlying FET rather than in the sensing region.


Asunto(s)
Técnicas Biosensibles , Dispositivos Electrónicos Vestibles , Diseño de Equipo , Concentración de Iones de Hidrógeno , Sistemas de Atención de Punto , Transistores Electrónicos
2.
Sensors (Basel) ; 19(12)2019 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-31212895

RESUMEN

We have investigated human-stress monitoring by making use of salivary nitrate, which can be a candidate for stress markers, with ion-selective field-effect transistors (ISFETs). ISFETs are suitable for on-site single-drop analysis of salivary nitrate within 10 s. However, when ISFETs are used for salivary nitrate, ISFETs have a problem that is called the initial drift. The initial drift makes accurate nitrate monitoring difficult. Thus, the purpose of this study is to prevent the initial drift and to search for a new, simple polymer to possess a better performance of sensor responses than conventional matrix membranes, such as PVC. In this research, we investigated ISFETs using specific matrix membranes, for example KP-13, Pellethane®--, and P7281-PU. The initial drift was evaluated from the fluctuations of the response values generated by the ISFETs when immersed in saliva or aqueous solution. As a result, P7281-PU showed a prevention effect on the initial drift, both in the whole saliva and in various solutions. Furthermore, the cause of drift may be H+ diffusion, and the drift prevention effect of P7281-PU may be affected by urethane bond capturing H+ in the ion-selective membrane. This result suggests that a continuous nitrate monitoring is feasible and may be applied to wearable sensors.


Asunto(s)
Biomarcadores/química , Técnicas Biosensibles , Nitratos/aislamiento & purificación , Saliva/química , Humanos , Monitoreo Fisiológico/métodos , Nitratos/química , Polímeros/química , Poliuretanos/química , Estrés Fisiológico , Transistores Electrónicos , Agua/química , Dispositivos Electrónicos Vestibles
3.
Biosens Bioelectron ; 257: 116311, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38677018

RESUMEN

One of the serious challenges facing modern point-of-care (PoC) molecular diagnostic platforms relate to reliable detection of low concentration biomarkers such as nucleic acids or proteins in biological samples. Non-specific analyte-receptor interactions due to competitive binding in the presence of abundant molecules, inefficient mass transport and very low number of analyte molecules in sample volume, in general pose critical hurdles for successful implementation of such PoC platforms for clinical use. Focusing on these specific challenges, this work reports a unique PoC biosensor that combines the advantages of nanoscale biologically-sensitive field-effect transistor arrays (BioFET-arrays) realized in a wafer-scale top-down nanofabrication as high sensitivity electrical transducers with that of sophisticated molecular programs (MPs) customized for selective recognition of analyte miRNAs and amplification resulting in an overall augmentation of signal transduction strategy. The MPs realize a programmable universal molecular amplifier (PUMA) in fluidic matrix on chip and provide a biomarker-triggered exponential release of small nucleic acid sequences easily detected by receptor-modified BioFETs. A common miRNA biomarker LET7a was selected for successful demonstration of this novel biosensor, achieving limit of detection (LoD) down to 10 fM and wide dynamic ranges (10 pM-10 nM) in complex physiological solutions. As the determination of biomarker concentration is implemented by following the electrical signal related to analyte-triggered PUMA in time-domain instead of measuring the threshold shifts of BioFETs, and circumvents direct hybridization of biomarkers at transducer surface, this new strategy also allows for multiple usage (>3 times) of the biosensor platform suggesting exceptional cost-effectiveness for practical use.


Asunto(s)
Técnicas Biosensibles , Diseño de Equipo , Límite de Detección , MicroARNs , Técnicas Biosensibles/instrumentación , MicroARNs/análisis , Humanos , Biomarcadores , Transistores Electrónicos , Sistemas de Atención de Punto , Dispositivos Laboratorio en un Chip
4.
IEEE Sens Lett ; 7(8): 1-4, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37529707

RESUMEN

Ion-sensitive field-effect transistors (ISFETs) in combination with unmodified complementary metal oxide semiconductors present a point-of-care platform for clinical diagnostics and prognostics. This work illustrates the sensitive and specific detection of two circulating mRNA markers for prostate cancer, the androgen receptor and the TMPRSS2-ERG fusion using a target-specific loop-mediated isothermal amplification method. TMPRSS2-ERG and androgen receptor RNA were detected down to 3x101 and 5x101 copies respectively in under 30 minutes. Administration of these assays onto the ISFET Lab-on-chip device was successful and the specificity of each marker was corroborated with mRNA extracted from prostate cancer cell lines.

5.
Biosensors (Basel) ; 13(10)2023 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-37887101

RESUMEN

In this paper, we propose a novel approach to utilize silicon nanowires as high-sensitivity pH sensors. Our approach works based on fixing the current bias of silicon nanowires Ion Sensitive Field Effect Transistors (ISFETs) and monitor the resulting drain voltage as the sensing signal. By fine tuning the injected current levels, we can optimize the sensing conditions according to different sensor requirements. This method proves to be highly suitable for real-time and continuous measurements of biomarkers in human biofluids. To validate our approach, we conducted experiments, with real human sera samples to simulate the composition of human interstitial fluid (ISF), using both the conventional top-gate approach and the optimized constant current method. We successfully demonstrated pH sensing within the physiopathological range of 6.5 to 8, achieving an exceptional level of accuracy in this complex matrix. Specifically, we obtained a maximum error as low as 0.92% (equivalent to 0.07 pH unit) using the constant-current method at the optimal current levels (1.71% for top-gate). Moreover, by utilizing different pools of human sera with varying total protein content, we demonstrated that the protein content among patients does not impact the sensors' performance in pH sensing. Furthermore, we tested real-human ISF samples collected from volunteers. The obtained accuracy in this scenario was also outstanding, with an error as low as 0.015 pH unit using the constant-current method and 0.178 pH unit in traditional top-gate configuration.


Asunto(s)
Técnicas Biosensibles , Nanocables , Humanos , Transistores Electrónicos , Silicio/química , Nanocables/química , Líquido Extracelular , Técnicas Biosensibles/métodos , Concentración de Iones de Hidrógeno
6.
ACS Sens ; 7(11): 3389-3398, 2022 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-36368032

RESUMEN

Prostate cancer (PCa) is the second most common cause of male cancer-related death worldwide. The gold standard of treatment for advanced PCa is androgen deprivation therapy (ADT). However, eventual failure of ADT is common and leads to lethal metastatic castration-resistant PCa. As such, the detection of relevant biomarkers in the blood for drug resistance in metastatic castration-resistant PCa patients could lead to personalized treatment options. mRNA detection is often limited by the low specificity of qPCR assays which are restricted to specialized laboratories. Here, we present a novel reverse-transcription loop-mediated isothermal amplification assay and have demonstrated its capability for sensitive detection of AR-V7 and YAP1 RNA (3 × 101 RNA copies per reaction). This work presents a foundation for the detection of circulating mRNA in PCa on a non-invasive lab-on-chip device for use at the point-of-care. This technique was implemented onto a lab-on-chip platform integrating an array of chemical sensors (ion-sensitive field-effect transistors) for real-time detection of RNA. Detection of RNA presence was achieved through the translation of chemical signals into electrical readouts. Validation of this technique was conducted with rapid detection (<15 min) of extracted RNA from prostate cancer cell lines 22Rv1s and DU145s.


Asunto(s)
Neoplasias de la Próstata Resistentes a la Castración , Humanos , Masculino , Neoplasias de la Próstata Resistentes a la Castración/diagnóstico , Neoplasias de la Próstata Resistentes a la Castración/genética , Neoplasias de la Próstata Resistentes a la Castración/tratamiento farmacológico , Receptores Androgénicos/genética , Receptores Androgénicos/metabolismo , ARN Mensajero/genética , Antagonistas de Andrógenos/uso terapéutico , Laboratorios , Pronóstico , ARN
7.
Biosensors (Basel) ; 11(6)2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-34205927

RESUMEN

The use of deoxyribonucleic acid (DNA) hybridization to detect disease-related gene expression is a valuable diagnostic tool. An ion-sensitive field-effect transistor (ISFET) with a graphene layer has been utilized for detecting DNA hybridization. Silicene is a two-dimensional silicon allotrope with structural properties similar to graphene. Thus, it has recently experienced intensive scientific research interest due to its unique electrical, mechanical, and sensing characteristics. In this paper, we proposed an ISFET structure with silicene and electrolyte layers for the label-free detection of DNA hybridization. When DNA hybridization occurs, it changes the ion concentration in the surface layer of the silicene and the pH level of the electrolyte solution. The process also changes the quantum capacitance of the silicene layer and the electrical properties of the ISFET device. The quantum capacitance and the corresponding resonant frequency readout of the silicene and graphene are compared. The performance evaluation found that the changes in quantum capacitance, resonant frequency, and tuning ratio indicate that the sensitivity of silicene is much more effective than graphene.


Asunto(s)
Sondas de ADN , Técnicas Biosensibles , Simulación por Computador , ADN/química , Capacidad Eléctrica , Grafito/química , Silicio/química , Transistores Electrónicos
8.
Sensors (Basel) ; 10(1): 61-83, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-22315527

RESUMEN

The use of microsensors for in-field monitoring of environmental parameters is gaining interest due to their advantages over conventional sensors. Among them microsensors based on semiconductor technology offer additional advantages such as small size, robustness, low output impedance and rapid response. Besides, the technology used allows integration of circuitry and multiple sensors in the same substrate and accordingly they can be implemented in compact probes for particular applications e.g., in situ monitoring and/or on-line measurements. In the field of microsensors for environmental applications, Ion Selective Field Effect Transistors (ISFETs) have a special interest. They are particularly helpful for measuring pH and other ions in small volumes and they can be integrated in compact flow cells for continuous measurements. In this paper the technologies used to fabricate ISFETs and a review of the role of ISFETs in the environmental field are presented.


Asunto(s)
Técnicas Biosensibles/instrumentación , Monitoreo del Ambiente/instrumentación , Transductores , Transistores Electrónicos , Diseño de Equipo , Análisis de Falla de Equipo , Miniaturización
9.
Sensors (Basel) ; 10(6): 6115-27, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-22219705

RESUMEN

Ion sensitive field-effect transistor (ISFET) based urease biosensors with solid state reference systems for single-ended and two-ended differential readout electronics were investigated. The sensing membranes of the biosensors were fabricated with urease immobilized in a conducting polymer-based matrix. The responses of 12.9∼198.1 mV for the urea concentrations of 8∼240 mg/dL reveal that the activity of the enzyme was not significantly decreased. Biosensors combined with solid state reference systems were fabricated, and the evaluation results demonstrated the feasibility of miniaturization. For the differential system, the optimal transconductance match for biosensor and reference field-effect transistors (REFET) pair was determined through the modification of the membranes of the REFETs and enzyme field-effect transistors (EnFETs). The results show that the transconductance curve of polymer based REFET can match with that of the EnFET by adjusting the photoresist/Nafion™ ratio. The match of the transconductance curves for the differential pairs provides a wide dynamic operating measurement range. Accordingly, the miniaturized quasi-reference electrode (QRE)/REFET/EnFET combination with differential arrangement achieved similar urea response curves as those measured by a conventional large sized discrete sensor.


Asunto(s)
Técnicas Biosensibles/instrumentación , Transistores Electrónicos , Urea/análisis , Técnicas Biosensibles/métodos , Técnicas Biosensibles/normas , Electroquímica/instrumentación , Electroquímica/métodos , Electroquímica/normas , Enzimas Inmovilizadas , Diseño de Equipo , Humanos , Iones/análisis , Modelos Biológicos , Modelos Teóricos , Estándares de Referencia , Reproducibilidad de los Resultados , Transistores Electrónicos/normas